frax is a computer-based algorithm which

51

Upload: others

Post on 08-Jul-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FRAX is a computer-based algorithm which
Page 2: FRAX is a computer-based algorithm which
Page 3: FRAX is a computer-based algorithm which

FRAX is a computer-based algorithm which uses easily obtained clinical risk factorsto estimate an individual’s 10-year fracture probability.It may be utilized by clinicians to assist in the identification of patients at high risk forfractures.

INTRODUCTORY STATEMENT

Page 4: FRAX is a computer-based algorithm which

The FRAX model determines the predictive importance of each clinical risk factor, as well as interactions between them, to optimize the accuracy of fracture probability.

It is primarily used as a clinical tool to help physicians assess fracture probability.

FRAX aid in identifying which individuals may be candidates for bone density evaluation or pharmacological treatment.

Page 5: FRAX is a computer-based algorithm which

FRAX does not take into account all risk variables ( ex. falls, markers of bone turnover levels, other bone density assessments, as well as certain secondary causes of osteoporosis).

FRAX uses yes/no answers and the average risk is computed.

Does not take into account the variation of risks associated with high or low doses of glucocorticoids, the number and type of prior fractures, or the quantity of alcohol or tobacco consumption.

Page 6: FRAX is a computer-based algorithm which

2010 ISCD-IOF FRAX Initiative and ISCD Position Development Conference

Bucharest, RomaniaNovember 12-14, 2010

Sanford Baim, MDAssociate Professor of Medicine

Division of EndocrinologyUniversity of Miami, Miller School of

Medicine

Page 7: FRAX is a computer-based algorithm which

FRAX may underestimate fracture probability in individuals with a parental history of non-hip fragility fracture.

Bone turnover markers are not included as risk factors in FRAX.

FRAX CLINICAL STATEMENTS

Page 8: FRAX is a computer-based algorithm which

Impaired functional status in patients with rheumatoid arthritis may be a risk factor for clinical fractures.

FRAX may underestimate fracture probability in such patients.

There is no consistent evidence that non-glucocorticoid medications for rheumatoid arthritisalter fracture risk.

FRAX CLINICAL STATEMENTSA.R.

Page 9: FRAX is a computer-based algorithm which

Paciente mujer 45 años con diagnostico de Artritis Reumatoide de 1 año de evolución con afectación de manos.

Sinovitis persistente de 3 meses de evolucionTratamiento.

Prednisolona 2.5 mg dia desde hace 9 meses. Metotrexate 7.5 mg semanal Ac folico . 1 mg dia

Naproxeno 250 mg dia

Rx manos. Erpsion marginal

VSG, 25FR. PositivoAnticitrulina . Neg

Page 10: FRAX is a computer-based algorithm which

Artritis Reumatoide de la manoDedos Fusiformes

© ACR

Page 11: FRAX is a computer-based algorithm which
Page 12: FRAX is a computer-based algorithm which
Page 13: FRAX is a computer-based algorithm which
Page 14: FRAX is a computer-based algorithm which
Page 15: FRAX is a computer-based algorithm which
Page 16: FRAX is a computer-based algorithm which

AR mostrando hinchazón persistente a nivel de las AR mostrando hinchazón persistente a nivel de las articulaciones IFPs junto con afectación de las MCFs articulaciones IFPs junto con afectación de las MCFs

que son dolorosas a la exploración clínicaque son dolorosas a la exploración clínicaColección de diapositivas ACR

Prednisolona 10 mg dia

Page 17: FRAX is a computer-based algorithm which
Page 18: FRAX is a computer-based algorithm which

Paciente 45 años con diagnostico de Artritis Reumatoide de 5 años de evolución con afectación de manos, hombros, rodillas.

Sinovitis persistente con formación de pannus sinovial.Limitación a la movilidad de hombros.Desviación cubital en manos

Tratamiento.Prednisolona dosis variables 5-15 mg día desde hace 18

meses. Coticoides IM de forma indisciplinada mtx 15 mg semanal

Embrel 50 mg semanal.ac folico

Rx manos. Erosiones óseas . Subluxacion.

Page 19: FRAX is a computer-based algorithm which
Page 20: FRAX is a computer-based algorithm which

Artritis Reumatoide de la manoMala alineación

Page 21: FRAX is a computer-based algorithm which
Page 22: FRAX is a computer-based algorithm which
Page 23: FRAX is a computer-based algorithm which

58 year old women. 8 years beyond menopause. Weight 60.5 Kg. No personal or family history of fracture.

BMD FN T-score = -2.4

Page 24: FRAX is a computer-based algorithm which
Page 25: FRAX is a computer-based algorithm which

77 year old women. Weight 53.6 Kg.. Mother experienced a hip fracture.

BMD: FN T-score = -1.4

Page 26: FRAX is a computer-based algorithm which
Page 27: FRAX is a computer-based algorithm which

There is a relationship between number of prior fractures and subsequent fracture risk. FRAX underestimates fracture probability in persons with a history of multiple fractures.

There is a relationship between severity of prior vertebral fractures and subsequent fracture risk. FRAX may underestimate fracture probability in individuals with prevalent severe vertebral fractures.

FRAX CLINICAL STATEMENTS

Page 28: FRAX is a computer-based algorithm which

L1(G2)

L1(G3)

L4(G3)

L2(G1)

L2(G2)

L5(G2)

L5(G3)

L2(G2)

L1(G2)

Page 29: FRAX is a computer-based algorithm which

There is a dose relationship between glucocorticoid use of greater than 3 months and fracture risk. The average dose exposure captured within FRAX is likely to be a prednisone dose of 2.5- 7.5 mg/day or its equivalent. Fracture probability is under-estimated when prednisone dose is greater than 7.5 mg/day and is over-estimated when prednisone dose is less than 2.5 mg/day.

Frequent intermittent use of higher doses of glucocorticoidsincreases fracture risk. Because of variability in the dose and dosing schedule, quantification of this risk is not possible.

High dose inhaled glucocorticoids may be a risk factor for fracture. FRAX may underestimate fracture probability in users of high dose inhaled glucocorticoids.

FRAX CLINICAL STATEMENTS

Page 30: FRAX is a computer-based algorithm which

Paciente varon 53 años, con antecedentes de (LES) lupus eritematoso sistemico en tratamiento a largo plazo con dosis altas de prednisona

› T-score columna Lumbar -1.6› T-score Cuello femoral -1.0 ( 2005)› T-score cuello femoral -1.6 ( 2007)

Page 31: FRAX is a computer-based algorithm which

Edad 51 a. / 2005

Steroid & Multi fractures

Page 32: FRAX is a computer-based algorithm which

Steroid & Multi fractures

Page 33: FRAX is a computer-based algorithm which

Steroid & Multi fractures

Page 34: FRAX is a computer-based algorithm which

Inicial 1-23-02 Estudio Actual 11-08-12Steroid & Multi fractures

T12

Page 35: FRAX is a computer-based algorithm which

Existe correlacion entre el uso de corticoides por mas de 3 meses y el riesgo de fractura

El promedio de dosis de corticoides incorporado en el FRAX es de 2.5 a 7.5 mg dia de prednisona o su equivalente

la probabilidad de fractura es subestimada cuando la dosis de prednisona es mayor de 7.5 mg/dia, y es sobre estimada cuando la

dosis de prednisona es menor de 2.5 mg/dia

Page 36: FRAX is a computer-based algorithm which

Debilidad sobre la dicotomía del uso del esteroide› FRAX asume un promedio de dosis expuesta

de esteroides (equivalente a la dosis media de GPRD)› > 7.5 mg de prednisona dia , indica mayor

riesgo de fractura que el que predice el FRAX.

Page 37: FRAX is a computer-based algorithm which

Debilidad sobre la dicotomia del uso del esteroide› FRAX asume un promedio de dosis de

esteroides› > 7.5 mg de prednisona dia , indica mayor

riesgo de fractura que el que predice el FRAX.

L a Obesidad podria no ser protectorala masa muscular puede no incrementarse con el peso

“Cuando QUEREMOS INTERPRETAR POSIBILIDADES, E

S

NECESARIO UTILIZAR EL JUICIO CLINICO”

“Cuando QUEREMOS INTERPRETAR POSIBILIDADES, E

S

NECESARIO UTILIZAR EL JUICIO CLINICO”

Page 38: FRAX is a computer-based algorithm which

While there is evidence that duration and dose of tobacco smoking may impact on fracture risk, quantification of this risk is not possible.

Falls are a risk factor for fractures but are not accommodated as an entry variable in the current FRAX model. Fracture probability may be underestimated in individuals with a history offrequent falls, but quantification of this risk is notcurrently possible.

FRAX CLINICAL STATEMENTSCigarrillo/caidas

Page 39: FRAX is a computer-based algorithm which

Varon 76 a. con antecedentes de múltiples caídas, hipertensión, hiperlipidemia, osteoartritis de rodilla y cadera, nicturia.› 25(oh) D = 26 ng/ml› Atorvastatina› ASA› HCTZ› metoprolol› Alprazolan› multivitamina

Page 40: FRAX is a computer-based algorithm which

Caidas multiples

Page 41: FRAX is a computer-based algorithm which

• Las caídas son un factor de riesgo para fracturas, pero no están incorporada como variable en el actual modelo de FRAX. La probabilidad de fractura podría estar subestimada en individuos con historia de caídas frecuentes, pero la cuantificación de este riesgo actualmente no es posible

Page 42: FRAX is a computer-based algorithm which

Riesgo de fractura parece ser mas elevado que el calculado por FRAX

Necesita realzmente los medicamentos para OSP?› Probablemnte reduciendo los

medicamentos, evaluando la parte nutricional ( BMI de 20 Kg/m2), considerar terapia fisica para fortalecimiento en MMII, evaluar por asistencia para soporte y estabilidad.

Pensar sobre el paciente y no solo

sobre la DMO o el calculo FRAX

Page 43: FRAX is a computer-based algorithm which

Measurements other than BMD or T-score at the femoral neck by Dual-energy X-ray Absorptiometry (DXA) are not recommended for use inFRAX.

FRAX may underestimate or overestimate major osteoporotic fracture risk when lumbar spine T-score is much lower or higher (>1 Standard Deviation discrepancy) than femoral neck T-score

FRAX BMD STATEMENTS

Page 44: FRAX is a computer-based algorithm which

• mujer 66 años• Fumadora• Menopausia 51 a.• Antecedentes de familiar de fractura• HTA . En tto. Con amlodipino

– Cuello femoral t-score -1.7– CL t-score – 3.5

Page 45: FRAX is a computer-based algorithm which

Discordancia CL / femur

Page 46: FRAX is a computer-based algorithm which

Discordancia CL / femur

Page 47: FRAX is a computer-based algorithm which

Frax riesgo mayor 12 %

Acorde con las guías canadienses la paciente esta justo por debajo del corte del 20%

Pero…… CL t-score -3.5

Page 48: FRAX is a computer-based algorithm which

Measurements other than BMD or T-score at the femoral neck by Dual-energy X-ray Absorptiometry (DXA) are not recommended for use in FRAX.

FRAX may underestimate or overestimate major osteoporotic fracture risk when lumbar spine T-score is much lower or higher (>1 Standard Deviation discrepancy) than femoral neck T-score

FRAX BMD STATEMENTS

Page 49: FRAX is a computer-based algorithm which

Algunas medidas con excepción de la DMO o T score a nivel del cuello femoral, no es recomendado para el uso del frax

Page 50: FRAX is a computer-based algorithm which

Cuello femoral› Predice todas las

fracturas +++› Predice fractura de

cadera +++› NHANES +++› Artefactos/exclusion

+› Mayoria de

cohortes en derivacion*

Columna lumbar› Predice todas las

fracturas +++› Predice fractura de

cadera ++› No equivalente› Artefactos/

exclusion +++› Minoria en

derivacion de cohorte**

*38,973 medidas en cuello de femur ( Johnell: JBMR 2005 20,1185-1194**19,071 se realizaron ambas mediidas ( Kanis OI 2005 17 527-534

Page 51: FRAX is a computer-based algorithm which

FRAX subestima o sobreestima el riesgo mayor de fractura osteoporotica cuando el t-score de columna lumbar es mas alto o bajo (≥ 1 discrepancia DS) que el t-score de cuello femoral.