FOX II Characteristics Balanced flue RLS system Energy efficiency Technical data Nominal heat output [kW] 8 Partial heat output [kW] 4 Room heating capacity (depending on house insulation) [m³] 90-210 Fuel consumption [kg/h] 1,1-2,2 Efficiency [%] 85,7 Energy efficiency class A+ Energy efficiency index 115,3 Chimney draft requirement [Pa] 12

Upload: others

Post on 01-Jun-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FOX II...FOX II Characteristics Balanced flue RLS system Energy efficiency Technical data Nominal heat output [kW] 8 Partial heat output [kW] 4 Room heating capacity (depending on

FOX II

Characteristics

Balanced flue RLS system Energy efficiency

Technical dataNominal heat output [kW] 8

Partial heat output [kW] 4

Room heating capacity (depending on house insulation) [m³] 90-210

Fuel consumption [kg/h] 1,1-2,2

Efficiency [%] 85,7

Energy efficiency class A+

Energy efficiency index 115,3

Chimney draft requirement [Pa] 12

Page 2: FOX II...FOX II Characteristics Balanced flue RLS system Energy efficiency Technical data Nominal heat output [kW] 8 Partial heat output [kW] 4 Room heating capacity (depending on

H

B TRO-T1

RO-T3RO-T2

RO

-H

F-H

F-S

R-H

R-S

RO-S

R-

F-

Chimney connection

In case of doubt as well as missing or incorrect translations, the German version is the only valid one. Technical and design changes, as well as typesetting and printing errors reserved.

© 2019 | RIKA Innovative Ofentechnik GmbH

Safety distances

Note1. To non-combustible objectsa > 40 cm b > 10 cm2. To combustible objects and reinforced concrete load-bearing walls a > 80 cm b > 20 cm

DimensionsH - Height [mm] 1039

B - Width [mm] 550

T - Corpus depth [mm] 494

WeightWeight without stones [kg] ~150

Weight with stones [kg] ~260

Thermal mass [kg] ~120

Flue pipe connectionR - Ø Flue pipe outlet [mm] 130

RO - H Original angle pipe connection height [cm] 152

RO - T1 Original angle pipe total depth [cm] 73

RO - T2 Original angle pipe distance to rear wall [cm] 24

RO - T3 Deapth from rear wall to middle of flue pipe [cm] 15

RO - S Original angle pipe side distance [cm] 28

R - H Rear connection height [cm] 85

R - S Rear connection side distance [cm] 28

Fresh air connectionF - Ø Diameter [mm] 125

F - H Connection height [cm] 17

F - S Side distance [cm] 28

Page 3: FOX II...FOX II Characteristics Balanced flue RLS system Energy efficiency Technical data Nominal heat output [kW] 8 Partial heat output [kW] 4 Room heating capacity (depending on

FOX II RIKATRONIC3

Characteristics

Balanced flue RIKATRONIC3 RLS system Energy efficiency

Technical dataNominal heat output [kW] 8

Partial heat output [kW] 4

Room heating capacity (depending on house insulation) [m³] 90-210

Fuel consumption [kg/h] 1,1-2,2

Electric supply [V/Hz.] 230/50

Average electrical input [W] 4

Fuse [A] 2,5

Efficiency [%] 85,7

Energy efficiency class A+

Energy efficiency index 115,3

Chimney draft requirement [Pa] 12

Page 4: FOX II...FOX II Characteristics Balanced flue RLS system Energy efficiency Technical data Nominal heat output [kW] 8 Partial heat output [kW] 4 Room heating capacity (depending on

H

B TRO-T1

RO-T3RO-T2

RO

-H

F-H

F-S

R-H

R-S

RO-S

R-

F-

Chimney connection

In case of doubt as well as missing or incorrect translations, the German version is the only valid one. Technical and design changes, as well as typesetting and printing errors reserved.

© 2019 | RIKA Innovative Ofentechnik GmbH

Safety distances

Note1. To non-combustible objectsa > 40 cm b > 10 cm2. To combustible objects and reinforced concrete load-bearing walls a > 80 cm b > 20 cm

DimensionsH - Height [mm] 1039

B - Width [mm] 550

T - Corpus depth [mm] 494

WeightWeight without stones [kg] ~150

Weight with stones [kg] ~260

Thermal mass [kg] ~120

Flue pipe connectionR - Ø Flue pipe outlet [mm] 130

RO - H Original angle pipe connection height [cm] 152

RO - T1 Original angle pipe total depth [cm] 73

RO - T2 Original angle pipe distance to rear wall [cm] 24

RO - T3 Deapth from rear wall to middle of flue pipe [cm] 15

RO - S Original angle pipe side distance [cm] 28

R - H Rear connection height [cm] 85

R - S Rear connection side distance [cm] 28

Fresh air connectionF - Ø Diameter [mm] 125

F - H Connection height [cm] 17

F - S Side distance [cm] 28