FOX II
Characteristics
Balanced flue RLS system Energy efficiency
Technical dataNominal heat output [kW] 8
Partial heat output [kW] 4
Room heating capacity (depending on house insulation) [m³] 90-210
Fuel consumption [kg/h] 1,1-2,2
Efficiency [%] 85,7
Energy efficiency class A+
Energy efficiency index 115,3
Chimney draft requirement [Pa] 12
H
B TRO-T1
RO-T3RO-T2
RO
-H
F-H
F-S
R-H
R-S
RO-S
R-
F-
Chimney connection
In case of doubt as well as missing or incorrect translations, the German version is the only valid one. Technical and design changes, as well as typesetting and printing errors reserved.
© 2019 | RIKA Innovative Ofentechnik GmbH
Safety distances
Note1. To non-combustible objectsa > 40 cm b > 10 cm2. To combustible objects and reinforced concrete load-bearing walls a > 80 cm b > 20 cm
DimensionsH - Height [mm] 1039
B - Width [mm] 550
T - Corpus depth [mm] 494
WeightWeight without stones [kg] ~150
Weight with stones [kg] ~260
Thermal mass [kg] ~120
Flue pipe connectionR - Ø Flue pipe outlet [mm] 130
RO - H Original angle pipe connection height [cm] 152
RO - T1 Original angle pipe total depth [cm] 73
RO - T2 Original angle pipe distance to rear wall [cm] 24
RO - T3 Deapth from rear wall to middle of flue pipe [cm] 15
RO - S Original angle pipe side distance [cm] 28
R - H Rear connection height [cm] 85
R - S Rear connection side distance [cm] 28
Fresh air connectionF - Ø Diameter [mm] 125
F - H Connection height [cm] 17
F - S Side distance [cm] 28
FOX II RIKATRONIC3
Characteristics
Balanced flue RIKATRONIC3 RLS system Energy efficiency
Technical dataNominal heat output [kW] 8
Partial heat output [kW] 4
Room heating capacity (depending on house insulation) [m³] 90-210
Fuel consumption [kg/h] 1,1-2,2
Electric supply [V/Hz.] 230/50
Average electrical input [W] 4
Fuse [A] 2,5
Efficiency [%] 85,7
Energy efficiency class A+
Energy efficiency index 115,3
Chimney draft requirement [Pa] 12
H
B TRO-T1
RO-T3RO-T2
RO
-H
F-H
F-S
R-H
R-S
RO-S
R-
F-
Chimney connection
In case of doubt as well as missing or incorrect translations, the German version is the only valid one. Technical and design changes, as well as typesetting and printing errors reserved.
© 2019 | RIKA Innovative Ofentechnik GmbH
Safety distances
Note1. To non-combustible objectsa > 40 cm b > 10 cm2. To combustible objects and reinforced concrete load-bearing walls a > 80 cm b > 20 cm
DimensionsH - Height [mm] 1039
B - Width [mm] 550
T - Corpus depth [mm] 494
WeightWeight without stones [kg] ~150
Weight with stones [kg] ~260
Thermal mass [kg] ~120
Flue pipe connectionR - Ø Flue pipe outlet [mm] 130
RO - H Original angle pipe connection height [cm] 152
RO - T1 Original angle pipe total depth [cm] 73
RO - T2 Original angle pipe distance to rear wall [cm] 24
RO - T3 Deapth from rear wall to middle of flue pipe [cm] 15
RO - S Original angle pipe side distance [cm] 28
R - H Rear connection height [cm] 85
R - S Rear connection side distance [cm] 28
Fresh air connectionF - Ø Diameter [mm] 125
F - H Connection height [cm] 17
F - S Side distance [cm] 28