fox 980 - arclaser.de2018_03_fox3_980... · ostly clinics and surgery centers used la- ... a.r.c....

8
LASER…INNOVATION MADE IN GERMANY www.arclaser.de FOX 980 nm, 12 W FOX IDEAL FOR: • LASER-CONCHOTOMY • LASER DCR, LACRIMAL DUCT • TONSILLOTOMY • ... EASE OF USE BATTERY POWERED GREEN AIMING BEAM DIODE LASER FOR ENT 980 nm

Upload: lykhue

Post on 15-Sep-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FOX 980 - arclaser.de2018_03_FOX3_980... · ostly clinics and surgery centers used la- ... A.R.C. Laser is focused on addressing nasal sinus infections, ... h Flexible bare fibers

LASER…INNOVATION MADE IN GERMANY

www.arclaser.de

FOX 980 nm, 12 W

FOX

IDEAL FOR:

• LASER-CONCHOTOMY

• LASER DCR, LACRIMAL DUCT

• TONSILLOTOMY

• ...

EASE OF USE

BATTERY

POWERED

GREEN AIMING

BEAM

DIODE LASER FOR ENT

980 nm

Page 2: FOX 980 - arclaser.de2018_03_FOX3_980... · ostly clinics and surgery centers used la- ... A.R.C. Laser is focused on addressing nasal sinus infections, ... h Flexible bare fibers

LASER…INNOVATION MADE IN GERMANY

A.R.C. Laser LASER TECHNOLOGY MADE IN GERMANY

M ostly cl inics and surgery centers used la-

sers in the past. Based on our affordable FOX

we are able to offer an inexpensive laser solution to

our clients - Expand your range of treatments. In-

vest in new technology for more success in your prac-

tice. Use the advantages of our Diode Laser FOX.

Get in touch with laser technology „Made in Germany“.

The FOX Laser is widely accepted throughout all health

service fields. This results in a dense net of users all over

the world and a reasonable retail price for our clients.

Intelligent solutions and motivated employees stand for a

high product quality.

A.R.C. Laser is the synonym for laser technology “Made

in Germany”. All research and development for our lasers

takes place in Germany. The international success made

A.R.C. one of the strongest laser company worldwide.

The roots of this privately held company located in

Nuremberg ranges back into the long history of laser

application in medicine.

The founders of Meditec GmbH (1978) brought the first

commercially available Nd:YAG laser (secondary cataract)

in ophthalmology to the market 1981, later on they had

the first Excimer-Laser for refractive surgery, the Meditec

Excimer Laser (MEL). Followed by the MEL 80 (Carl Zeiss

Meditec), this system still represents an high power of

innovation.

A.R.C. Laser is a technology company specialized in the

development, production and sales of laser systems like

ENT, Ophthalmology, Aesthetic surgery and Dermatology,

Phlebology with a strong arm in Dentistry.

Thinking of Ophthalmology we hold more than 60 patents

in this field with its extent range of applications. Today, the

laser is uncompromising the tool of 1st choice.

Today‘s patient expectations are more demanding than

ever. We‘ve brought together an experienced team of en-

gineers that knows how to meet and exceed patient ex-

pectations by utilizing advanced technology.

We cordially invite you to

scroll with us through this

brochure to get an idea

of the development of

diode laser for ENT made

by A.R.C. Laser.

Angela ThyzelCEO A.R.C. Laser

2

Page 3: FOX 980 - arclaser.de2018_03_FOX3_980... · ostly clinics and surgery centers used la- ... A.R.C. Laser is focused on addressing nasal sinus infections, ... h Flexible bare fibers

DESIGN, PERFORMANCE AND VALUE FINALLY CONVERGE

FOX is an essential component to any OR or office.

FOX is a more practical alternative to large, expensive lasers.

FOX is unmatched in performance.

PORTA BLE . A F FOR DA BLE . VERSATILE.

The FOX offers up to 12 W - sufficient power for almost any treatment.

3

Page 4: FOX 980 - arclaser.de2018_03_FOX3_980... · ostly clinics and surgery centers used la- ... A.R.C. Laser is focused on addressing nasal sinus infections, ... h Flexible bare fibers

LEADERSHIP IN LASERS FOR ENT

Our laser equipment targets the needs of Otolaryngologists and Rhinologists.

In addition, A.R.C. Laser is focused on addressing nasal sinus infections,

such as Chronic Rhinosinusitis (CRS). Our partner in the U.S. has successfully

completed its human feasibility studies and has begun U.S. clinical studies

on the use of its proprietary, minimally invasive light based therapy.

Lasers have become the treatment of choice for most procedures and

consequently there is an increased interest in sophisticated, yet practical

devices. It is a challenge to meet the demand of patients and physicians for

applications with better results. A.R.C. Laser meets this challenge all around

the globe.

1) Tuboplasty 2) Conchotomy – 2012 Dr. Jumah, Villingen-Schwenningen, Germany

4

Page 5: FOX 980 - arclaser.de2018_03_FOX3_980... · ostly clinics and surgery centers used la- ... A.R.C. Laser is focused on addressing nasal sinus infections, ... h Flexible bare fibers

THE UNIVERSAL LASER FOR TREATMENTS IN ORL

Oral Fibroma - no bleeding - rapid healing

Laser-Turbinoplasty inside the nasal cavity to reduce the inferior turbinate.

Laser DCR with the FOX 980 nm

Tonsillectomy

Epistaxis Control - non contact

Endoscopy / Micro endoscopy

h Eustachian tube

h Lacrimal passages

h Saliva way

h Micro otology

h Micro sinus surgery

Oral/Larynx /Surgery

h Polypectomy in area of vocal ligaments

h Polyps-/ papilloma resection

h Epistaxis treatment

h Laryngeal carcinoma

h Cysts, mucous cysts

h DCR treatment / Lacrimal surgery

h Removal of stenois in lacrimalis

h Synechia, stenosis in endonasal structures

h Tumor, Granuloma resection

h Congenital larynx stenosis

h Hemangiomas

h Morbus Osler

Otology

h Paracentesis, myringotomy

h Mucosa hyperplasia

h Stapes surgery

h Removal of cholesteatoma

Nasal

h Laser assisted tuboplasty of the eustachian tube (LETP) with a special micro endoscope

h Turbinate treatment

h Septum spur, septum deformation

h Nasal sinus surgery

h Tonsillotomy, tonsillectomy/LAUP

Postoperative pain is signifi-cantly reduced when com-pared to non laser procedures: Minimal or no requirement for anesthetics.

5

Page 6: FOX 980 - arclaser.de2018_03_FOX3_980... · ostly clinics and surgery centers used la- ... A.R.C. Laser is focused on addressing nasal sinus infections, ... h Flexible bare fibers

A.R.C. LASER SAFETY AND USABILITY

The FOX opens a new dimension in the treatment of the mouth and throat. FOX-Diode-Laser cuts without almost any bleeding and allows precise handling.

Optimum results – modern laser technology

FOX rapidly coagulates blood vessels due to its wavelength of 980 nm.

FOX is available at a fraction of the cost of other lasers.

FOX should be present in every physician’s office.

FOX minimal costs for disposables.

h TOUCH-SCREEN – Treatment at your finger tips

h Compact dimensions, low weight and battery powered

h High portability and well suited for a wide range of applications

h Short Pulses (0.1 ms) for reduced pain and improved course of healing

h Stores your individual treatment parameters

h Flexible bare fibers for a huge range of movement

h High quality and lossless laser coupling

h Inexpensive disposables

h Affordable price

h 2 year warranty

Patented Click-FibersHigh-quality laser coupling for the precise connection of fiber optic and laser

6

Page 7: FOX 980 - arclaser.de2018_03_FOX3_980... · ostly clinics and surgery centers used la- ... A.R.C. Laser is focused on addressing nasal sinus infections, ... h Flexible bare fibers

FOXFOX

810, 940, 980, 1064 nm

Abmessungen FOX

Wavelength OptiOns:

FOX Diode laser

the world‘s first diode laser with output calibration

Treatment at your finger tips

Not without my FOX!

the most versatile and affordable surgical laser!

Power Meter

Power Supply

Door Interlock

AUX 1 / AUX 2

Foot Switch

tOuch - select - treat

Power Calibration hat Fiber Distal Tip Green hAiming BeamVideo Screen hCapability

Green aiming beam for hpinpoint accuracy

Store up to 99 treatment hprograms in memory

Battery operation enables hunlimited range of usage

Superior performance for hmaximum utilization

Video library is available hvia USB flash drive

Expand your office services with the FOX.

Unlimited benefits offered by the FOX.

Partner with us to develop new advancements.

Dimensions FOX

Rear Connectors FOX

FOX laser and ac-cessories are stowed in a durable carrying case.

SPECIFICATIONSWavelength/Power* 810 nm

940 nm 980 nm

1064 nm

8 Watt 4 Watt

12 Watt10 Watt

Pulse Width / adjustable 0.1 ms to cw

Pulse Intervall 0.1 ms to cw

Aiming Beam Green 532 nm, < 1 mW

Dimensions (WDH) 142 x 163 x 174 mm

Weight 1.2 kg

Input Voltage Integrated Batteries, rechargeable

* at the distal end

Specify wavelength at order.Changes in design and specifications to enhance performance will be incor- porated without any further notice.

Fast and easy change of the fibers - click-in / click-out.

Adjusted – ready to use.

LASEr rAdIATIONAVOID EXPOSURE TO BEAM CLASS 4 LASEr PrOdUCT

P = 15 Watt, 810-1064 nmP < 2 mW, 532 nm

VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION

DIODE LASER 810-1064 nm = 15 Watt CWDIODE LASER 532 nm < 2 mW CW

CLASS 4 LASER PRODUCT

A.R.C. Laser GmbHBessemerstraße 14D-90411 NürnbergGermany

+49 (0) 911 217 79-0 +49 (0) 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifie

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/ 2

003

- 93/

42 E

WG

Pro

d. N

o: F

OX

2Se-

11-2

010

163

174

142

192

108

163

174

142

192

108

163

174

142

192

108

FOX_Systemprospekt_NEU.indd 1-3 15.03.2011 12:08:42

FOXFOX

810, 940, 980, 1064 nm

Abmessungen FOX

Wavelength OptiOns:

FOX Diode laser

the world‘s first diode laser with output calibration

Treatment at your finger tips

Not without my FOX!

the most versatile and affordable surgical laser!

Power Meter

Power Supply

Door Interlock

AUX 1 / AUX 2

Foot Switch

tOuch - select - treat

Power Calibration hat Fiber Distal Tip Green hAiming BeamVideo Screen hCapability

Green aiming beam for hpinpoint accuracy

Store up to 99 treatment hprograms in memory

Battery operation enables hunlimited range of usage

Superior performance for hmaximum utilization

Video library is available hvia USB flash drive

Expand your office services with the FOX.

Unlimited benefits offered by the FOX.

Partner with us to develop new advancements.

Dimensions FOX

Rear Connectors FOX

FOX laser and ac-cessories are stowed in a durable carrying case.

SPECIFICATIONSWavelength/Power* 810 nm

940 nm 980 nm

1064 nm

8 Watt 4 Watt

12 Watt10 Watt

Pulse Width / adjustable 0.1 ms to cw

Pulse Intervall 0.1 ms to cw

Aiming Beam Green 532 nm, < 1 mW

Dimensions (WDH) 142 x 163 x 174 mm

Weight 1.2 kg

Input Voltage Integrated Batteries, rechargeable

* at the distal end

Specify wavelength at order.Changes in design and specifications to enhance performance will be incor- porated without any further notice.

Fast and easy change of the fibers - click-in / click-out.

Adjusted – ready to use.

LASEr rAdIATIONAVOID EXPOSURE TO BEAM CLASS 4 LASEr PrOdUCT

P = 15 Watt, 810-1064 nmP < 2 mW, 532 nm

VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION

DIODE LASER 810-1064 nm = 15 Watt CWDIODE LASER 532 nm < 2 mW CW

CLASS 4 LASER PRODUCT

A.R.C. Laser GmbHBessemerstraße 14D-90411 NürnbergGermany

+49 (0) 911 217 79-0 +49 (0) 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifie

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/ 2

003

- 93/

42 E

WG

Pro

d. N

o: F

OX

2Se-

11-2

010

163

174

142

192

108

163

174

142

192

108

163

174

142

192

108

FOX_Systemprospekt_NEU.indd 1-3 15.03.2011 12:08:42

3 rdGeneration

FOX Diode Laser

The growing demand for inexpensive laser applications in ENT is supported by disposable hand pieces.

These meet the increased requirements for sterility and operating capability.

*

SPECIFICATIONS FOX 980 nm

LL11058s Otology Probe long 20°, sterileLL11059s Otology Probe angled 20°, sterile

LL13003 Bare fiber 200 µm LL13003s Bare fiber 200 µm, sterile LL13001 Bare fiber 300 µm LL13001s Bare fiber 300 µm, sterile LL13017s Bare fiber 400 / 300 µm, sterileLL13008s Bare fiber 600 / 300 µm, sterileLL11053s Bare fiber 400 µm, sterile

Bare fibers with 200, 300, 400, 600 µm

length: 2.65 m

A.R.C. Laser accessories:

Straight Otology Probes various lenghts

ZU01024Angled Otology-Probe

HS11018Surgery Handpiece

ZU01029Otology Probe

7

Page 8: FOX 980 - arclaser.de2018_03_FOX3_980... · ostly clinics and surgery centers used la- ... A.R.C. Laser is focused on addressing nasal sinus infections, ... h Flexible bare fibers

03.0

4.18

A.R.C. Laser GmbHBessemerstr. 1490411 NurembergGermany

A.R.C. Laser GmbHBessemerstr. 1490411 NurembergGermany

� +49 911 217 79-0� +49 911 217 79 [email protected]

� +49 911 217 79-0� +49 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifi e

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/

2003

- 9

3/42

EW

G

Spe

cific

atio

ns a

re s

ubje

ct to

cha

nge

with

out n

otic

e.

www.arclaser.com

Änderungen an Ausstattung und Spezifi kationen, die dem technischen Fortschritt dienen, werden auto-matisch durchgeführt.

Änderungen an Ausstattung und Spezifi kationen, die dem technischen Fortschritt dienen, werden automatisch durchgeführt.

Specifi cations are subject to change without notice.

Specifi cations are subject to change without notice.

A.R.C. Laser reserves the right to alter the technical specifi cations described and illustrated in this brochure at any time and without notice. Please consult your A.R.C. Laser retailer for the latest details concerning technical specifi cations.

A.R.C. Laser behält sich das Recht vor, jegliche technische Daten und Eigenschaften der beschriebenen oder gezeigten Geräte jederzeit ohne Vorankündigung zu modifi zieren. Aktuelle Werte erhalten Sie in der Regel nur direkt bei Ihrem A.R.C. Vertreter.

A.R.C. Laser GmbHBessemerstr. 1490411 NurembergGermany

A.R.C. Laser GmbHBessemerstr. 1490411 NurembergGermany

� +49 911 217 79-0� +49 911 217 79 [email protected]

� +49 911 217 79-0� +49 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifi e

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/

2003

- 9

3/42

EW

G