fourier systems products catalog

52
Fourier Systems Data Acquisition Solutions Committed to Quality

Upload: olil

Post on 24-May-2015

1.373 views

Category:

Education


8 download

TRANSCRIPT

Page 1: Fourier systems products catalog

Fourier SystemsData Acquisition Solutions

Committed to Qual i ty

Page 2: Fourier systems products catalog

Fourier Systems, Inc.

9611 W. 165th St., Suite 11b

Orland Park, IL, USA 60467

Customer Support: (877) 266-4066

Fax: (708) 364-9555

[email protected]

www.fouriersystems.com

Page 3: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

Fourier Systems Ltd.www.fouriersystems.com

1

Fourier Systems is recognized as an innovative developer, manufacturer and distributor of

compact portable data logging devices and accessories for advanced data acquisition,

communications and analysis. Our products are the ideal cost effective solution across the

full spectrum of industry, including pharmaceutical, food transportation, storage, air

conditioning and ventilation, clean rooms, warehouses and galleries.

Fourier Systems data acquisition solutions include:

• MicroLite: Multi-trip plug-and-log USB temperature data logger

• DataNet: Wireless RF network logger, based on ZigBee protocol

• DaqPRO: 8-channel, stand-alone, multi-data acquisition logger

• MicroLog/MicroLogPRO: Temperature and humidity, long-term, portable data logger

Fourier is dedicated to providing sophisticated quality solutions that integrate the most

advanced technologies. When it comes to professional data logging, leading companies

around the world count on Fourier to provide them with the most up-to-date, cost effective

equipment.

Fourier’s Competitive Advantage:

Product Advantages

• Immediate ROI: Zero implementation

and infrastructure costs

• Quality: Better specifications in inputs,

accuracy, memory, sampling rates

• Flexibility: Data transfer to PC

• Independence: On-site monitoring via

graphic displays

• Intuitive: Simple keypads & icon driven

menus

Company Advantages

• Nearly 20 Years of Experience:

Established knowledge-base & proven

applications

• In-house Wireless Technology:

Reducing cost & time to market

• Responsive: High R&D investment

meeting distributor feedback and

market needs

• Low Pricing: Efficient operation &

outsourced manufacturing

Page 4: Fourier systems products catalog

www.fouriersystems.com

Fourier Systems Distributors2

Fourier Systems partners with value added

resellers in more than 60 countries across all

continents. Our distributors have sales

experience and expertise in the data

acquisition market and understand the

importance of commitment to excellence.

“The intuitive, easy to use MicroLab software facilitates

detailed analysis of the shipment from origin to destination and

allows Sea Star to optimize its shipping process. The MicroLite

has paid for itself many times over in shipping and materials

savings.”

Robert Soares, Marketing Administrator, Sea Star Seafood

Corporation

“The singular difference with Fourier, is that they approached

our business needs the same way we approach those of our

clients…they got on our team and helped as find solutions.”

Bob Belveal, President ShelfLife Distributors, USA

Page 5: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

3

“Fourier Systems enable us to meet brewery and winery

regulatory guidelines within our budget, with ease and

efficiency and very little staff maintenance.”

Andy Correa, Operations Manager Dienst Distributing Co.,

USA

“I feel my feedback from the field is listened to and acted

upon. They really listen to their customers and develop

products according to the market need.”

Amir Antebi, Managing Director, SITEST, Australia

“I have applied the DataNet system in dozens of different

applications: Government buildings, hotels chains, museums,

hospitals and laboratories have found the DataNet to be a key

solution for wireless, cost effective and accurate monitoring.”

Marcial Ferro, Director MF Instruments, Spain

“We settled with Fourier because they met our three most

important criteria: value for money, flexibility and aesthetics.”

Hans Oosterling, Managing Director of CaTeC Bv, Netherlands

Page 6: Fourier systems products catalog

www.fouriersystems.com

Fourier Systems Goals4

oday, companies face more stringent

commercial and hazard analysis

standards than ever before. Whether

centrally monitoring data from a fleet of

trucks or numerous workstations in a

Lab, they all face rigid restrictions and

tightening profit margins. It is these

challenges that Fourier’s wireless and

cost effective solutions cater to.

T

Page 7: Fourier systems products catalog

Committedto Qual i ty

5

DataNet Solution ......................................................................................7 DataNet Data Logger .................................................................8 Mini DataNet Data Logger .......................................................10 DataNet Software .....................................................................12

MicroLite Solution ...................................................................................17 MicroLite Data Logger ..............................................................18 MicroLab Lite Software ............................................................19

DaqPRO Solution .....................................................................................21 DaqPRO Data Logger ...............................................................23 DaqLab Software ......................................................................24

MicroLog Solution ...................................................................................27 MicroLog and MicroLogPRO Data Loggers .............................28 MicroLog and MicroLogPRO Sensors ......................................29 MicroLab Software ...................................................................30

DatPass Software ....................................................................................33

Ordering Information .............................................................................35 for DataNet ...............................................................................35 for MicroLite .............................................................................38 for DaqPRO ...............................................................................39 for MicroLog and MicroLogPRO ..............................................41

Specifications ..........................................................................................45 for DataNet ...............................................................................45 for Mini DataNet .......................................................................46 for MicroLite .............................................................................46 for DaqPRO ...............................................................................46 for MicroLog and MicroLogPRO ..............................................47

Table of Contents

Commit ted to Qual i ty

DataNet PC SuiteSoftware

Copyright© 2008 Fourier System s Ltd

.

www.fouriersystems.com

Supported Operating Systems

Windows® 2000 Service Pack 3

Windows® Server 2003

Windows® XP Service Pack 2

Windows® Vista

Hardware requirements

Pentium 700 MHz

64 MB RAM

100 MB available disc space

Page 8: Fourier systems products catalog

www.fouriersystems.com

Page 9: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

DataNet SolutionWireless intelligent logging network

DataNet is a multi-unit data acquisition system. Data transmission

from end units to the central computer utilizes the ZigBee wireless

telemetry protocol. DataNet data loggers feature 16-bit resolution,

with four external channels supporting direct measurement and

recording of PT-100, thermocouple, voltage, current, dry contact,

frequency and pulse. Internal sensors include temperature and

humidity.

ZigBee wireless protocol uses a 2.4 GHz license-free frequency RF

Band. Each DataNet unit also serves as a transmission repeater to

neighboring units, forming a reliable mesh network of up to 65,000

units. The ZigBee key features include:

• Reliable bi-directional transmission ensuring no data loss

• Transmission range can be constantly expanded by adding

additional network units

• Minimal costs thanks to wire-free infrastructure

• Portable units facilitating easy deployment in various

environments

• Receiver, recognizing up to 8 end units and 16 Repeaters

• Repeaters, recognizing up to 24 end units and 16

Repeaters (simultaneously)

7

Page 10: Fourier systems products catalog

www.fouriersystems.com

DataNet SystemContains:

Temperaturedata logger

with 4 external inputs

RH/Temperaturedata logger

with 4 external inputs

Receiver/Repeater

Mini DataNetDNL810

(RH/Temperature) DNL808

(external NTC 10 KΩ )

DRY GOODSDRY GOODS

DRY GOODS

BAKERY

VEGETABLES

DAIRY

MEAT

OFFICE

MM

MM650m

80m

80m

DataNet Network - Supermarket

DataNet Infrastructure Network

Hospital Parallel MonitoringWithin a Single DataNet Network

DataNet Solution8

NetworkAdministrator

Wards

Wards

Wards

Laboratories& Refrigerators

Basement

(2132 ft)

(262 ft)

(262 ft)

Page 11: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

DataNet Features DataNet system comprises two models meeting a wide range of industry applications:

• DNL910 logger with four external inputs and one internal Temperature sensor.

Supported external inputs: 4 to 20 mA, 0 to 1 V, 0-50 mV, PT-100 2-wires, Thermocouples

(J, K and T), Dry Contact, Pulse Counter and Frequency.

• DNL920 logger with four external inputs and one internal Temperature and Humidity sensor.

Same supported external inputs as DNL910 logger.

LCD Screen

Menu Button

Scroll/On Button Mini USBConnector

AC Socket

Data LoggerExternal Inputs (4)

12V Excitation

DataNet Solution Case Study

Company:Teva Pharmaceutical Industries Ltd. One of the top 20 Global pharmaceutical companies in the world. Develops and markets branded pharmaceuticals & active ingredients.

Challenge:• 10 large storage facilities in separate cities with perishable pharmaceuticals. • Temperature must be measured wirelessly but external RF interference threatened data loss.

Requirements:• Online multiple point monitoring and alert system.• Avoid costly infrastructure by using wireless network.

• Maintain reliable RF transmission.

Solution:• DataNet provides a secured intelligent data logging system.• Overcomes RF interference, recovering data losses.

Method:Multiple DataNet units with external PT100 temperature probes monitor ambient temperature every 15 minutes. Repeaters are used to cover distances of 200 to 300m inside the warehouse. Data is exported to Microsoft Excel for further analysis.

9

Internal sensor housing

Page 12: Fourier systems products catalog

www.fouriersystems.com

Mini DataNet LoggersֿSupported by the DataNet wirelessZigBee network

The Mini DataNet, a single and dual channel data monitoring system, reduces

potentially redundant costs of the four-channel monitoring system.

• Dual channel internal Temperature and Humidity sensor for cost effective

data acquisition

• Also supports external NTC sensor, providing an easily extended solution

• External antenna, increasing transmission distance

• Runs up to 12 months on a single battery

Antenna

Dual-colorLED Indicator

Multi-functionButton

Internal DigitalRH & TemperatureSensor

External NTCsensor connection

DataNet Solution10

DNL810

DNL808

Mini DataNet Network

OFFICE

650m

80m 80m

650m(2132 ft)

(262 ft) (262 ft)

(2132 ft)

Page 13: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

11

USB DataNetStand AloneSolution

Broadening the functionality of the DataNet system, the low-cost, stand-

alone USB DataNet is an ideal solution for non-wireless applications. Users

requiring just 4 external inputs and internal temperature and humidity can

still leverage the benefits of the DataNet system. With this simpler and

more budget-friendly option, customers only need a single USB DataNet

unit and PC software suite to start recording and analyzing data.

The USB DataNet extends the DNL910 and DNL920 to offer both wireless

and non-wireless operational modes with full functionality including:

• Manual operation (Run/Stop)

• Long battery life - 6 months between recharges

• Option to include DatPass software meeting 21 CFR Part 11

requirements

• Four alarm levels with unit external visual and audio alarm

• External AC power operation and internal rechargeable batteries

• Periodical download of data

• Real-time operation with live data results appearing on screen

• Firmware updates via the software

• Option to work in parallel to the ZigBee wireless network

DataNet specifications apply but wireless

features are not enabled.

Page 14: Fourier systems products catalog

www.fouriersystems.com

The DataNet PC Suite

Software provides security

for your products with online

monitoring and control of the

entire intelligent DataNet

system.

DataNet Software PC Suite

DataNet Solution12

Operating System: Windows 2000 SP3/ 2003/XP SP2/VistaInternet Explorer 5.01 or higher Pentium 800 MHz or higher 256 MB RAM 250 MB available disk space

Data View Features

Real-time data in

multiple displays (show

table, graph, Excel)

• International date format

• Ability to rename every logger and external input

• Map View displaying unit location, signal path and signal strength to the PC

Page 15: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

13

Alarm Features

Alarm level setup with email & SMS

notifications

Four alarm levels, allowing for

programming of 4 separate parameters,

with alarm delay and duration

Alarm Notification Setup

Alarm notifications sent to selected

Contacts and Groups during working

hours

Page 16: Fourier systems products catalog

www.fouriersystems.com

DataNet Solution14

Analysis Features

Dew point analysis, FO Pasteurization,

histogram, statistics with export to Excel

and CSV formats

Setup Features

Logger setup with Celsius or Fahrenheit

view

User configurable data file and text file

storage path

Ability to define custom sensors based

on current, voltage and pulse inputs

Page 17: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

15

Reporting Features

Individual Report Profile Manager:

• User can define up to 10 report

profiles

• Report generated and automatically

sent to multiple defined user profiles

• Reports received according to

predefined date interval selection

• Configurable report periods (start/

end dates)

• Daily, weekly and monthly reports

available

• Report file formats available in Excel

and PDF

Report Content:

• Alarm and Event log

• Data and Graph (Sensor histogram)

Views

• Email and SMS log

Hardware Communication Features

Over-the-air firmware updates and

calibration

Page 18: Fourier systems products catalog

www.fouriersystems.com

Page 19: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

MicroLite SolutionThe plug & record mini data logger

Aesthetic and innovative, MicroLite is a small data logger for monitoring and recording temperature. MicroLite is the ultimate plug and record data logger with direct USB connection to the computer. Despite the compact design, MicroLite data is clearly displayed on the logger’s numeric screen. In addition, the MicroLite stored data can be downloaded automatically to the MicroLab Lite software. The MicroLite has been dustproof and waterproof tested to meet highest market standards (IP68). To further ensure easy global usage, the battery is easily replaceable since it is a standard model used worldwide.

The product is designed for ultimate application accessibility, whether mobile or static. Typical applications for this product include transportation as well as warehousing of food, drugs and hi-tech equipment.

• High functionality, multi-trip plug-in logger• Dust and water proof, IP68/NEMA6 ; 30 minutes at 0.5 m (1.7 ft) depth• LCD numeric decimal point display - showing min/max and current values• Real-time, accurate historical data indicator• Long battery life with easily replaceable industry standard • Supports USB 2.0 interface enabling fast track communication • High resolution 16-bit (0.1 ºC) and high accuracy of 0.3 ºC • Large sample memory: Optional 8,000 or 16,000 samples • Fast sampling rate of once per second • Range -40 ºC to 80 ºC (-40 °F to 176 °F) • Start sampling options: Magnet key, automatic and timer • Fast automatic data download to graph, table, export to Excel

17

Page 20: Fourier systems products catalog

www.fouriersystems.com

MicroLite Features

MicroLite Solution18

MicroLite Case Study

Company:Sea Star, Established in 1983Ships highly perishable frozen seafood samples to brokers and customers across the United States.

Challenge: Using correct quantities of frozen gel packs during shipments. Too few would result in product spoilage, and too many causing excessive air freight charges.

Requirements: • A water resistant logger that is compact, accurate, low cost and easy-to-use. • Data analysis software that could provide detailed analysis of the shipment from origin to destination, allowing Sea Star to optimize its shipping process.

Solution: MicroLite: Accurate and reliable temperatures monitoring during shipping

Result:Substantial cost savings in air freight, refrigerant packs, and minimized product loss.

Method:• MicroLite placed inside insulated shipping boxes with a postage-paid return envelope to Sea Star after shipment delivery. • The logger is programmed to start when the courier arrives to pick up the package. • Samples are recorded at 1 minute intervals during the overnight shipment. • Once the logger is returned to Sea Star, data is downloaded for analysis.

Water Tight Cap

LCD Screen

USB Connector

Battery Magnet Key(for manual start/run)

Sensor Compartment

1. Record data

2. USB connection to PC

3. MicroLab Lite graphical data display

Page 21: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

19

MicroLite

works with

MicroLab Lite

software whose features

have been designed

specifically in response to

requests from the field

enabling a broader and more

complex range of application

environments. Features

include analysis functionality

such as Statistics – maximum,

minimum and average,

enabling a quick glance

summary of the environment

and historical analysis. This is

typically useful for

applications requiring a

constant bird’s eye picture of

the conditions their materials

are kept in.

Download MicroLab Lite software from Fourier Systems website:www.fouriersystems.com

Setup

MicroLite configuration

Analysis

Histogram + Statistics

Output

Table view + Graph alarm +

Excel export

MicroLab Lite Software for MicroLite

Downloadfor Free

Operating System: Windows 2000/ME/XP/Vista16 MB RAM10 MB Disk spaceScreen resolution 800/600 or higher

GMT RecordingSetting data recording to meet with GMT - Greenwich Mean Time for use in international environments, particularly export and import.

Page 22: Fourier systems products catalog

www.fouriersystems.com

Page 23: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

DaqPRO SolutionAll-in-one system for universal data acquisition and analysis

The DaqPRO™ is a portable, battery operated data

acquisition and logging system offering 16-bit, high-

resolution, 8 channel data logging. The DaqPRO features

powerful graphical display and analysis functions for

measuring voltage, current and temperature. It is designed

to provide a professional, compact, stand-alone low cost

data logging system for a wide variety of applications.

• High-end data acquisition hand-held mobile solution

• 8 channels each capable of measuring seven popular parameters

• Setup on every port makes it viable for all industries

• Stand-alone operation: Display and keyboard for field programming

and analysis (graph/table)

• Rechargeable 7.2V battery with over 500 charging cycles

• High sampling rate – up to 4,000 samples/second

• Large data storage 512 KB RAM

• Fast communication channels: USB

• Multiple logging storage of up to 100 sampling sessions

• Scales readings into meaningful engineering units e.g. bar, ppm

• Built-in clock and calendar keeps track of time and date for each data

recording

• On screen text editing to annotate collected data

21

Page 24: Fourier systems products catalog

www.fouriersystems.com

DaqPRO LCD ScreensDaqPRO provides truly independent data acquisition with full setup, data display and analysis all on the DaqPRO.

DaqPRO Solution22

Main Menu

Setup

Configuration

Numeric& graphicdata display

Notes

File storage

Page 25: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

23

DaqPRO Features

LCD screen

Enter/Start button

Forward/Back button

Escape/Stop button

On/Off buttons

Detachable screw terminal

DaqPRO Solution Case Study

Company:American Honda Car Manufacturer

Challenge:• Honda technicians perform onsite Honda engine compatibility tests • Measuring different engine location operating temperatures

Requirements:• Simple, turn-key, independent, battery operated • Onsite data display and analysis without PC connection

Solution:DaqPRO can provide on-the-spot accurate and complete information

Method:

• 6 different scenarios are used on the DaqPRO when testing, each at default setting• Ambient temperature sensor in I/O-1 and anywhere from 2 to 5 type K thermocouples for other inputs

Page 26: Fourier systems products catalog

www.fouriersystems.com

• Runs on Windows 95/98/2000/ME/XP and VISTA, as well as PDA platforms• Fast data download from the DaqPRO• Data displayed in numeric or graphical display forms• Graphical analysis tools such as Zoom and Cursors• Storage of selected data on disk files• Hard copy printing of the collected data• Direct data export to EXCEL• On-line retrieval and display of data in real-time• Incorporating data processing functions• Setting up the DaqPRO• Calibrating the DaqPRO• Defining new sensors

Online Logger Setup

Online Graph & Table View

Meter View

For Analog, Bar or Digital data

display

Export to Excel

Define New Sensors:

Defining a custom sensor

Operating System: Windows 95/98/2000/XP/Vista 16 MB RAM10 MB Disk spaceScreen resolution 800/600 or higher

DaqLab Software for DaqPRO

Analysis Wizard

Scientific Functions - Statistics

Sensor Calibration

Copyr ight

©

2003Four ier Systems Ltd.

www.fouriersystems.com

DaqLab™

for TriLog and DaqPRO

PC requirements

Windows® 95/98/2000/ME/XP/NT 4.0 or higher

16MB RAM

10MB Disk space

Screen resolution 800/600 or higher

DaqPRO Solution24

Page 27: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

25

Page 28: Fourier systems products catalog

www.fouriersystems.com

Page 29: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

MicroLog SolutionGeneral data logger

• 8 year legacy of customer satisfaction, reliability and application experience

• Up to 3 parameters: Temp, RH and external sensors

• Accurate, portable 8-bit (MicroLog) and 10-bit (MicroLogPRO) data loggers

• All data viewing, export, and printing is done via two function keys

• View up to 30 days min/max history on LCD screen

• Water and dust proof (IP65/NEMA 4)

• Infrared communication to portable thermal printer

• Records months of data – up to 16,000 or 52,000 samples

• External sensors include: Temperature, pH, 4 to 20 mA, 0 to 10 V

• 4 to 20 mA and 0 to 10 V inputs allow for connection with any industry

standard sensors

• Sensor values are displayed in their own units on the LCD

• MicroLab analysis software enabling powerful monitoring and data

analysis capability

27

The MicroLog solution family offers two low-cost portable

data loggers:

Internal sensor models for:

• Temperature

• Temperature/RH

Plus selected range of external sensors

Microlog MicroLogPRO

Page 30: Fourier systems products catalog

www.fouriersystems.com

A compact 8-bit data logger capable of recording data for

months, even long-term shipping and storage. All data

viewing, data export, and printing is done via two function

keys.

• External input enables additional data collection from a

variety of external sensors

• View up to 30 days min/max history

• Built-in quality sensors for temperature and humidity

• Programmable sampling rate

• Records months of data - up to 16,000 samples

• Low and high alarm level programming

The 10-bit MicroLogPRO has all of the benefits of the 8-bit

MicroLog in addition to the following enhancements:

• Higher sampling resolution for more accurate readings

• Increased memory - 52,000 samples

• Enhanced 4 digit LCD

Compact 8-bit Data Logger-30 to 50 °C (-22 to 122 °F)

MicroLog Solution28

MicroLog Case Study

Company:Company: Exporter Greenwings and Wageningen Industry: Agro technologists - Cut flowers exporter Holland to Japan

Challenge:High temperature and humidity levels during worldwide export journeys of up to a week reduce quality and humidity, causing botrytis.

Requirements:Tracking and tracing system charting delivery from supplier to customer and determine where obstacles occur to enable proactive, preventative measures.

Solution:MicroLog humidity and temperature data logger monitor the journeys’ climate conditions and help structurally reduce

quality loss of the flowers by developing a quality progress report.

Method:MicroLog data loggers are attached to the flowers, measuring temperature and humidity every 30 minutes. Upon arrival in Japan, the data loggers are removed by the customer and mailed back to Greenwings in attached envelopes. The data on the data loggers is then uploaded via an Internet site to a central database.

LCD screen

Compact 10-bit Data Logger -40 to 80 °C (-40 to 176 °F)

Data history by day button

Data history by hour button

Infrared printing

Enhanced 4-digit LCD screen

Push to Run modefor manual start

Page 31: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

29

1. Record data

2. Recorded data is printed via infrared beam

3. Data printout displays Min, Max, Average and Duration

1. Record data

2. Connect to PC via RS232 cable

3. Display data graphically in MicroLab

MicroLog External Sensors

MicroLog Operating Method

MicroLog Temperature DT132 (2.5 m)MicroLog Temperature DT093 (10 m)Range: -50 to 100 °C (-58 °F to 212 °F)Resolution: <1 °C (33.8 °F)

MicroLogPRO Temperature DT132 (2.5 m)MicroLogPRO Temperature DT093 (10 m)Range: -50 to 110 °C (-58 °F to 230 °F)Resolution: <0.3 °C (37.4 °F)

MicroLog DT168 pHAdapter & ElectrodeRange: 1 to 14 pHResolution: 0.116 pH

MicroLogPRO DT168 pHAdapter & ElectrodeRange: 1 to 14 pHResolution: 0.02 pH

MicroLog DT140 Voltage Adaptor Range: 0 to 10 VResolution: 0.05 V

MicroLogPRO DT140 Voltage AdaptorRange: 0 to 10 VResolution: 0.01 V

MicroLog/MicroLogPRO DT139Current AdapterRange: 4 to 20 mAResolution: ±0.1 mA

Page 32: Fourier systems products catalog

www.fouriersystems.com

• Downloads from MicroLog

• Graph & table displays

• Alarm levels per MicroLog displays

• Ability to configure MicroLog

• Sensor definition

• Comments for each data logger

• Automatic data saving

• Daily status reports in various formats

Data can be clearly identified

according to the ID number

of the logger it came from

and the threshold relevant to

that logger. MicroLab

automatically saves the data

and produces daily status

reports of your environment.

Data Management

Data records can be exported

to Excel or CSV file format

using the Export to Excel

feature

Data Analysis

Mean kinetic temperature,

an expression of cumulative

thermal stress in different

temperatures during storage,

transportation and

distribution.

Operating System: Windows 98/2000/ME/XP/Vista16 MB RAM10 MB Disk spaceScreen resolution800/600 or higher

MicroLab Softwarefor MicroLog & MicroLogPRO

MicroLog Solution30

Pasteurization provides analysis for the most common methods of pasteurization in Industry: High Temperature Short Time (HTST); Ultra Pasteurization (UP) and Ultra High Temperature (UHT) pasteurization.

Histogram provides a graphical view of historical results presented according to defined parameters of periods of time and percentage levels. This provides a level of analysis which can be tailored to specific environment needs for an immediate picture. For example, this can be used in a museum environment where the percentage of time the humidity reached certain levels can be viewed.

Annotation feature enables text marks to be placed on the graph at relevant points where certain information needs to be highlighted.

GMT RecordingSetting data recording to meet with GMT - Greenwich Mean Time for use in international environments, particularly export and import.

Page 33: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

31

MicroLog & MicroLogPRO Comparison Table

Page 34: Fourier systems products catalog

www.fouriersystems.com

Page 35: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

DatPassFDA Title 21 CFR Part 11 CompliantSupporting DataNet & MicroLab software

What is Title 21 CFR Part 11?

CFR is a Food and Drug Administration (FDA) issued

regulation Title 21 Code of Federal Regulations, Part 11. This

provides the criteria for acceptance by FDA, under certain

circumstances, of electronic-records, electronic-signatures,

and handwritten signatures which have been executed to

electronic records as equivalents to paper records and

handwritten signatures executed on paper. The intention of

these regulations, which apply to all FDA program areas, are

to permit the widest possible use of electronic technology,

compatible with FDA’s responsibility to promote and protect

public health.

Part 11 applies to any record governed by an existing FDA

predicate rule that is created, modified, maintained,

archived, retrieved, or transmitted using computers and/or

saved on durable storage media.

What is DatPass

DatPass is a user administration software which supports

the assignment of passwords and operating privileges for

Fourier industry application software. DatPass works with

MicroLab and DataNet software. DatPass defines the users

that can log onto the DatPass being used, their passwords

and digital signatures needed for electronic records.

33

Page 36: Fourier systems products catalog

www.fouriersystems.com

Page 37: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

DataNet Solution Ordering Information

35

Part Number DataNet System

DNL910 Internal Temperature RF logger + 4 external inputs • External Inputs: 0 to 1 V, 4 to 20 mA, Thermocouple (J, K, T), PT-100 (2-wire), Pulse Counter, Dry Contact, Frequency • 12 V power excitation • Includes AC power adapter

DNL920 Internal Temperature/Humidity RF logger + 4 external inputs • External Inputs: 0 to 1 V, 4 to 20 mA, Thermocouple (J, K, T), PT-100 (2-wire), Pulse Counter, Dry Contact, Frequency • 12 V power excitation • Includes AC power adapter

DNL810 Internal Temperature/Humidity RF logger • Temperature range: -20 to 50 °C (-4 to 122 °F) • Humidity range: 5 to 95 % • Internal 3.6 V battery • External antenna

DNL808 External NTC 10 KΩ RF logger • NTC 10 kΩ probe • Range: -50 to 150 °C (-58 to 300 °F) • Internal 3.6 V battery • External antenna • NTC probe length 240 cmDNR900 Receiver / Repeater * • Built-in amplifier • Includes AC power adapter * Every ZigBee DataNet wireless network requires one DNR900 Receiver.

12504 GSM Modem (for SMS alerts) • RS232 • Frequency Bands: GSM-850/EGSM-900/DCS-1800 PCS-1900 MHz Quad-Band

Part Number DataNet Accessories

12753 PT-100 sensor (2-wire) • Range: -70 to 400 °C (-94 to 752 °F) • 2.5 m (8.2 ft) Teflon cable length • Teflon cable range: -65 to 200 ˚C (-85 to 392 ˚F) 12752 PT-100 sensor (2-wire) • Range: -70 to 400 °C (-94 to 752 °F) • 4 m (13 ft) Teflon cable length • Teflon cable range: -65 to 200 °C (-85 to 392 °F)

Ordering Tips!

1. Every DataNet network purchased must be ordered with at least one DNR900 Receiver unit, in order to create and manage the network.2. Add more Repeaters to your network in order to cover potential RF blind spots.3. Stand alone DNL910 and DNL920 loggers run on the same software as the wireless DataNet loggers. No Receiver is needed to download the data to the PC.

Page 38: Fourier systems products catalog

www.fouriersystems.com

DataNet Solution Ordering Information

Part Number DataNet Accessories

12751 PT-100 sensor (2-wire) • Range: -70 to 400 ˚C (-94 to 752 ˚F) • 6 m (19 ft) Teflon cable length • Teflon cable range: -65 to 200 ˚C (-85 to 392 ˚F)

11304 Internal battery pack 4.8 V 800 mAh NiMH (2 batteries in series)

DN-PCSUITE PC Suite • DataNet software CD • Mini USB communication cable (for DNR900) • User guide * One DN-PCSUITE is needed in every ZigBee DataNet network

SFTMCL025A-2 DatPass for DataNet, meeting 21 CFR Part 11 compliance • DatPass software CD • USB security dongle • Validation manuals

12655 Mini USB communication cable For DNR900 • 5-pin Mini USB to Type A • 1 m cable length

DT246 110/12V AC/DC US adapter For DNR900, DNL910 and DNL920

DT245 220/12V AC/DC European adapter For DNR900, DNL910 and DNL920

DT282 220/12V AC/DC UK adapter For DNR900, DNL910 and DNL920

Ordering Information36

Page 39: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

DataNet Solution Ordering Information

Part Number Mini DataNet Accessories

13129 Mini DataNet external antenna 2.4 GHz SMA 5 DBI

12928 Mini DataNet internal battery 2/3 AA 3.6 V lithium

DT332 Temperature probe • NTC 10 kΩ • Range: -50 to 150 °C

DN-PCSUITE PC Suite • DataNet software CD • Mini USB communication cable (for DNR900) • User guide * One DN-PCSUITE is needed in every Mini DataNet network

SFTMCLO25A-2 DatPass for DataNet, meeting 21 CFR Part 11 compliance • DatPass software CD • USB security dongle • Validation manuals

12655 Mini USB communication cable For DNR900 • 5-pin Mini USB to Type A • 1 m cable length

37

Page 40: Fourier systems products catalog

www.fouriersystems.com

MicroLite Solution Ordering Information

Part Number MicroLite

LITE5008 MicroLite USB Temperature logger • Range: -40 to 80 °C (-40 to 176 °F) • 8,000 sample memory

LITE5016 MicroLite USB Temperature logger • Range: -40 to 80 °C (-40 to 176 °F) • 16,000 sample memory

Part Number MicroLite Accessories

11597 Replacement magnet key

13052 Replacement O-ring

10734 Replacement lithium battery • Range: -40 to 80 °C (-40 to 176 °F) • 3V CR2032

Ordering Information38

Ordering Tips!

1. MicroLite is defined as IP68. You can submerge the logger to a depth of half a meter for up to half an hour only.2.No need to purchase MicroLab Lite software since it is available for free download from www.fouriersystems.com.

Page 41: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

DaqPRO Solution Ordering Information

Part Number DaqPRO

DB5301 DaqPRO 8-channel data acquisition device Measuring 0-10 V, 4-20 mA, TC / J, K, T, PT-100 (2 and 3-wire), NTC 10 k and 100 k, Pulse Counter, Frequency

Bundle includes: DaqPRO data logger, DaqLab software, USB communication cable, user guide and carrying case

Part Number DaqPRO Accessories

DT332 DaqPRO compatible NTC Temperature probe • NTC 10 kΩ • Range: -25 to 150 °C (-13 to 302 °F)

12753 PT-100 sensor (2-wire) • Range: -70 to 400 °C (-94 to 752 °F) • 2.5 m (8.2 ft) Teflon cable length • Teflon cable range: -65 to 200 °C (-85 to 200 °F)

12752 PT-100 sensor (2-wire) • Range: -70 to 400 °C (-94 to 752 °F) • 4 m (13 ft) Teflon cable length • Teflon cable range: -65 to 200 °C (-85 to 200 °F)

12751 PT-100 sensor (2-wire) • Range: -70 to 400 °C (-94 to 752 °F) • 6 m (19 ft) Teflon cable length • Teflon cable range: -65 to 200 °C (-85 to 200 °F)

11460A Weather box IP67 standard compliant

AC040 10 W solar panel (DaqPRO must be modified)

11791 6A charging regulator

39

Ordering Tips! When ordering the DaqPRO, all necessary accessories (e.g. AC adapter, USB cable, etc.) are bundled together with the logger. There is no need to order them separately.

Page 42: Fourier systems products catalog

www.fouriersystems.com

DaqPRO Solution Ordering Information

Part Number DaqPRO Accessories

DT084 Rechargeable battery 12 V, 1.2 AH for solar panel (2 batteries required)

DT180 USB communication cable

DT246 110/12 V AC/DC US adapter For DaqPRO

DT245 220/12 V AC/DC European adapter For DaqPRO

DT282 220/12 V AC/DC UK adapter For DaqPRO

11599 Replacement rechargeable battery pack (GP1600MA 7.2 V battery pack)

Ordering Information40

Page 43: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

MicroLog Solution Ordering Information

Part Number MicroLog/MicroLogPRO

EC600A MicroLog Temperature logger • Range: -30 to 50 °C (-22 to 122 °F) • 8-bit resolution

EC650A MicroLog Temperature and Humidity logger • Range: Temperature -30 to 50 °C (-22 to 122 °F) Humidity 10 to 90 % rH • 8-bit resolution

EC700A MicroLogPRO Temperature logger • Range: -40 to 80 °C (-40 to 176 °F) • 10-bit resolution

EC750A MicroLogPRO Temperature and Humidity logger • Range: Temperature -40 to 80 °C (-40 to 176 °F) Humidity 5 to 95 % rH • 10-bit resolution

Part Number MicroLog/MicroLogPRO Accessories

BK041 User Guide For MicroLog/MicroLogPRO system

DT058 MicroLog/MicroLogPRO communication cable Connecting to Serial port only

41

Ordering Tips!

1. For the MicroLogPRO EC750 only, you can order the PC Kit which includes a mini USB cable instead of a Serial cable.2.MicroLog bundle includes the logger only. The software must be ordered separately.

Page 44: Fourier systems products catalog

www.fouriersystems.com

MicroLog Solution Ordering Information

Part Number MicroLog/MicroLogPRO Accessories

DT239 Mini USB communication cable For MicroLogPRO EC750A only

DT132A External Temperature sensor • MicroLog range: -50 to 100 °C (-58 °F to 212 °F) • MicroLogPRO range: -50 to 110 ° C (-58 °F to 230 °F) • 2.5 m (8.2 ft) cable length

DT093A External Temperature sensor • MicroLog range: -50 to 100 °C (-58 °F to 212 °F) • MicroLogPRO range: -50 to 110 °C (-58 °F to 230 °F) • 10 m (32.8 ft) cable length

DT132N External Temperature needle sensor • MicroLog range: -50 to 100 °C (-58 °F to 212 °F) • MicroLogPRO range: -50 to 110 °C (-58 °F to 230 °F) • 2.5 m (8.2 ft) cable length

DT139A External 4-20 mA adapter

DT140A External 0-10 V adapter

DT168A External pH adapter 1-14 pH (electrode not included)

DT018 pH electrode

DT086 3.6 V Lithium battery

Ordering Information42

Page 45: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

MicroLog Solution Ordering Information

Part Number MicroLog/MicroLogPRO Accessories

AC004 Infrared printer for data print-out

11199 Calibration certificate Available through advance order Price is per channel

PC-KIT PC Kit • MicroLab software CD • MicroLog communication cable

PC-KIT-750-USB PC Kit for EC750 • MicroLab software CD • Mini USB communication cable for EC750

SFTMCL025A DatPass for MicroLab, meeting 21 CFR Part 11 compliance • DatPass software CD • USB security dongle

43

Page 46: Fourier systems products catalog

www.fouriersystems.com

Page 47: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

DataNet Solution Specifications

45

INPUTS

• 4 channel inputs• Selectable type for each input: 4 to 20 mA, 0 to 50 mV, 0 to 1 V, PT-100,Thermocouple, Dry Contact, Pulse Counter (Input 4 only), Frequency (Input 4 only) and user defined sensors

INPUT TYPES

4 to 20 mA• Range: 4 to 20 mA• Resolution: 4.76 µA• Accuracy: ±0.5 %• Loop impedance: 21 Ω• Maximum load: 30 mA, 5.2 V

0 to 50 mV• Range: 0 to 50 mV• Resolution: 3 µV• Accuracy: ±0.5 %• Input impedance: 25 MΩ• Maximum voltage: 5.2 V

0 to 1 V• Range: 0 to 1 V• Resolution: 200 µV• Accuracy: ±0.5 %• Input impedance: 25 MΩ• Maximum voltage: 5.2 V

Temperature PT-100 (2-wires)• Range: -200 to 400 ˚C• Resolution: 0.1 ˚C• Accuracy: -200 to -60 ˚C ±0.5 % 60 to 400 ˚C ±0.5 % -60 to 60 ˚C ±0.3 ˚C

Temperature Thermocouple J• Range: -200 to 1,000 ˚C • Resolution: 0.1 ˚C• Accuracy: -200 to -60 ˚C ±0.5 % 60 to 1,000 ˚C ±0.5 % -60 to 60 ˚C ±0.5 ºC• Cold junction compensation error: ±0.3 ºC

Temperature Thermocouple K• Range: -200 to 1,000 ºC• Resolution: 0.1 ˚C• Accuracy: -200 to -60 ˚C ±0.5 % 60 to 1,000 ˚C ±0.5 % -60 to 60 ˚C ±0.5 ˚C• Cold junction compensation error: ±0.3 ˚C

Temperature Thermocouple T• Range: -200 to 400 ˚C• Resolution: 0.1 ˚C• Accuracy: -200 to -60 ˚C ±0.5 % 60 to 400 ˚C ±0.5 % -60 to 60 ˚C ±0.5 ˚C• Cold junction compensation error: ±0.3 ˚C

Dry Contact• Range: Open/Closed

Pulse Counter (input 4 only)• Zero crossing detector• Range: 1 to 65,536 counts• Resolution: 1 count• Frequency range: 0 to 4,000 Hz

• Input signal: 0 to 5 V• Input impedance: 470 Ω

Frequency (input 4 only)• Zero crossing detector• Range: 20 Hz to 4 KHz• Input signal: 0 to 4,000 Hz• Input impedance: 470 Ω Internal Temperature• Type: DNL 910: PT-100 DNL 920: Digital• Range: -20 to 50 ˚C (-5 to 50 ˚C while using the batteries w/o AC)• Resolution: 0.1 ˚C• Accuracy: DNL 910: ±0.3 ˚C DNL 920: ±0.5 ˚C

Internal Humidity• Range: 5 to 95 %• Resolution: 0.5 %• Accuracy: ±3 % at 10 to 90 % ±5 % at 5 to 10 % and 90 to 95 %

EXTERNAL SENSORS

PT-100 Sensor• Range: -70 to 400 ˚C • Cable length: 2.5m/4m/6m• Teflon cable range: -65 to 200 ˚C• Probe: Diameter 6 mm, Length 81 mm

CONNECTIVITY

External Power Excitation (transducers usage)• 12 VDC @ 2 A

Alarm Output (output 1)• Open collector• Close position resistance: 50 Ω• Max. Load: 50 mA, 3 V DC• Overload protection• 50 mA reset fuse

PC Communication• USB 2.0 compliance

Type of USB Cable• Mini USB type B

RF Network Communication • Frequency: 2.4 GHz• Network units: 65,000• Data rate: 250 Kbps• Full mesh network architecture supported• 128-bit network security encryption• Worldwide license-free• RF Transmission range boost mode 80 m (line of sight)• RF Transmission range power amplifier 800 m (line of sight)

Sampling Features• Memory capacity: 59,000 samples• Sampling rate: 1 per sec to 1 per every 2 hours (For PT-100 or Thermocouple sensors: Max Sampling rate with more than two sensors connected 1 sample per 2 secs)• Sampling resolution: 16 bit• Channel separation: 80 dB

Man Machine Interface• Full keyboard operation

Display• 2 row LCD• 16 character display

Power Supply• Internal rechargeable 4.8 V NiMH battery• Built-in battery charger• External 12 V DC input

Operating Temperature Range• -20 to 50 ˚C

Casing• Plastic ABS box• Dimensions: 97 x 93 x 27 mm • Weight: 200 gr

Standards Compliance• CE, FCC• Internal battery specs: 4.8 V 800 mAh NiMH battery (2 batteries in series)• External voltage specs: DC 12 V @ 300 mA 3.6 VA

GSM MODEM EZ-10

Frequency Bands• GSM-850/EGSM-900/DCS-1800 PCS-1900 MHz Quad-Band

GPRS• Class 10

RJ11 AUX Connector• GPIO

Interface Configurations• RS232: Serial Interface • Power: 12V DC

Dimensions• 83 x 107 x 64 x 33 mm

Temperature Range• Normal: -10 to +55 ˚C• Extreme: -20 to +70 ˚C• Storage: -30 to +85 ˚C

DATANET SOFTWARE

Main Features• Windows® based software • Data displayed in numeric or graphical display of all inputs• On-line retrieval and display of the collected data in real-time• Definition of new sensors • Ability to read the defined sensor’s units on the logger’s display• Full calibration of the loggers via the software • Documentation and filing • Alarm levels on graphs • Export to spreadsheets • Analytical functions, for professional analysis of the collected data• Manual backup of calibration settings • Over-the-air firmware update

Length and Temperature specifications are provided in Metric and Celsius units

Page 48: Fourier systems products catalog

www.fouriersystems.com

MicroLite SolutionSpecifications

Mini DataNet SolutionSpecifications

Internal Sensor Temperature: -40 to 80 ºC Thermal conductor enabling fast response time

Outputs USB 2.0 communication

SamplingResolution: A/D resolution: 16-bit, 0.1 °CCapacity: Memory capacity: 8 KB,16 KB Sampling rate: 1 per second to 1 per 2 hoursAccuracy: 0.3 °C

Power SupplyBattery life: 2 years at 1 sample per minute Replaceable 3 V lithium battery CR2032

DesignDimensions: 11 x 3.9 x 2.6 cm Strap-on capabilities

Weight 45.5 gr

Display LCD with decimal point Visual Alert - Alarm icon when crossing predefined thresholds Low battery indication

Operation Data scroll on the LCD Reed switch to start measuring

Software MicroLab Lite for Windows 2000/XP/Vista Also available – DatPass 21 CFR Part 11 Standards Compliance Software

Standards Compliance CE, FCC compliance IP68/NEMA6 30 minutes for 0.5 m depth

DNL808 External Temperature Sensor • Range: -50 to 150 °C• Resolution: 0.06 °C• Accuracy: -50 to 60 ˚C ±0.3 ˚C 60 to 150 ˚C ±0.5 %

DNL810 Internal RH/Temperature Sensors • Temp range: -20 to 50 °C• Temp resolution: 0.04 °C• Temp accuracy: ±0.4 °C• Humidity range: 5 to 95 %• Humidity resolution: 0.5 %• Humidity accuracy: ±3 %

Specifications46

INPUTS (DAQPRO 5300)

Selectable type for each input: 0-24 mA, 0-50 mV, 0-10 V, NTC, PT-100, Thermocouple, Pulse and Frequency (Input 1 only)

0 to 24 mA Range: 0 to 24 mAResolution: 4.76 µAAccuracy: ±0.5 %Loop impedance: 21 Ω

0 to 50 mV Range: 0 to 50 mVResolution: 3 µVAccuracy: ±0.5 %

0 to 10 VRange: 0 to 10 VResolution: 200 µV Accuracy: ±0.5 %Input impedance: 125 KΩ

Temperature NTC NTC: 10/100 KΩ resistorRange: -25 to 150 ºCResolution: 0.05 ºCAccuracy: ±0.5 %

Temperature PT-100 Range: -200 to 400 ºCResolution: 0.1 ºC (7 mΩ)Accuracy: -200 to -50 ±0.5 % 50 to 400 ±0.5 % -50 to 50 ±0.5 ºCThe DaqPRO offers up to 8 PT-100 2 wire channels or 4 PT-100 3 wire channels

Temperature Thermocouple JRange: -200 to 1200 ºCResolution: 0.1 ºC (1 µV)Accuracy: -200 to -50 ±0.5 % 50 to 1,200 ±0.5 % -50 to 50 ±0.5 ºCCold junction compensation error: ±0.3 ºC

Temperature Thermocouple KRange: -250 to 1,200 ºCResolution: 0.1 ºC (1 µV)Accuracy: -250 to -50 ±0.5 % 50 to 1,200 ±0.5 % -50 to 50 ±0.5 ºCCold junction compensation error: ±0.3 ºC

Temperature Thermocouple TRange: -200 to 400 ºCResolution: 0.1 ºC (1 µV)Accuracy: -200 to -50 ±0.5 % 50 to 400 ±0.5 % -50 to 50 ±0.5 ºCCold junction compensation error: ±0.3 ºC

Internal TemperatureRange: -25 to 70 ºCResolution: 0.1 ºC (1 µV)Accuracy: ±0.3 ºC

Pulse Counter (Input 1 only)Optocoupler inputRange: 0 to 65,000Input signal: 0 to 5 VInput impedance: 470 ΩBandwidth: 0 to 25 Hz

Frequency Meter (Input 1 only)Optocoupler inputRange: 20 to 4,000 HzInput signal: 0 to 5 VInput impedance: 470 Ω

General A to D SpecificationsNoise: 30 µV rmsInternal linearity error: ±0.08 % of FSROffset error: 0.1 %

Open Collector Output (Output 8)Maximum current sink: 50 mA (fuse protected)Maximum input voltage: 5 VInput impedance: 50 Ω

CommunicationUSB 1.1 compliant

SamplingCapacity: 512 KBAnalog sampling rate: Variable, 1 sample/hour to 4,000 samples/sec, 1 channelAnalog sampling resolution:16-bitChannel separation: 80 dB

Man Machine Interface• Full keyboard operation - enables manual programming of the logger• Graphic LCD 64 x 128 pixels

Power Supply• Internal rechargeable 7.2 V NiMH battery • Built-in battery charger• External 9 to 12 V DC input• Battery life: 25 hours between charges

Operating TemperatureRange: 0 to 50 ºC

CasingPlastic ABS boxDimensions: 182 x 100 x 28 mmWeight: 450 gr Standards ComplianceCE, FCC

DaqLab Analysis Software• Windows based software: 2000 SP3/2003/XP SP2/Vista Internet Explorer 5.01 or higher• Data displayed in numeric or graphical display forms• Graphical analysis tools such as Zoom and Cursors• Storage of selected data on disk files• Hard copy printing of the collected data• Direct data export to EXCEL• On-line retrieval and display of data in real-time• Incorporating data processing functions• Setting up and alibrating the DaqPRO• Defining new sensors

Accessories• Carrying case• Solar cell and battery for field data logging• Weather box complying with the IP-67 standard for protecting the DaqPRO while working in field applications

DaqPRO SolutionSpecifications

Length and Temperature specifications are provided in Metric and Celsius units

Page 49: Fourier systems products catalog

www.fouriersystems.com

Committedto Qual i ty

MicroLog Solution Specifications

47

MICROLOG SOLUTION MODELS

MicroLog EC600 Temperature plus external sensor MicroLog EC650 Temperature, relative humidity plus external sensorMicroLogPRO EC700 Temperature plus external sensorMicroLogPRO EC750 Temperature and relative humidity plus external sensor

BUILT-IN SENSORS

MicroLog TemperatureRange: -30 to 50 ˚CResolution: 0.5 ˚CAccuracy: ±0.6 ˚C

MicroLog HumidityRange: 10 to 90 %Resolution: 0.5 %Accuracy: ±3 %

MicroLogPRO Temperature Range: -40 to 80 ˚CResolution: 0.2 ˚C (-40 to -20 ˚C) 0.1 ˚C (-21 to 50 ˚C) 0.2 ˚C (51 to 80 ˚C) Accuracy (all ranges): ±0.2 ˚CSoftware calibration is possible

MicroLogPRO Humidity Range: 5 to 95 %Resolution: 0.1 %Accuracy: ±2 %Software calibration is possible

OUTPUT

MicroLog Display: 2 digit 7-segment LCDMicroLogPRO Display: 4 digit 7-segment LCD with decimal point

Communication • MicroLog IR - interface to portable HP printer • RS232 communication to the PC with 19,200 kbps with MicroLog and MicroLogPRO• USB 1.1 (MicroLogPRO)

Memory MicroLog: 16,000 samplesMicroLogPRO: 1 sensor - 52,000 samples 2 sensors - 26,000 samples 3 sensors - 16,000 samplesPower SupplyInternal lithium battery: 3.6V TL5902Battery life: Approximately 2 years (depending on sampling rate)

Sampling RateUser defined: From 1 every 10 seconds to 1 every two hours

Dimensions Width: 22.9 mmDiameter: 72 mmWeight: 55 gr

Standards• Water and dust proof IP65 standard compliance, for EC600 and EC700 models• CE and FCC standard compliance• FDA Title 21 CFR Part 11 Compliance

MICROLAB SOFTWARE

• Runs on Windows® 95/98/2000/XP/Vista• Fast data download from the MicroLog• Graphic visualization of the MicroLog data• Data displayed in graphs and tables• Data Export to EXCEL• Graphic analysis tools such as Markers, Zoom• Data Map allowing the users to easily see many MicroLog data loggers in one screen• MicroLog SETUP windows, for setting up the MicroLog sample rate, sensors and alarm level• MicroLog sensor calibration • Display of MicroLog battery level• Showing daily reports of a fleet of data loggers• Visual alarm levels on the graph and table

Minimum PC requirements

• Windows® 95 or later• Pentium 300 MHz or higher• 32 MB RAM• 6 MB available disk space• Available communication port

Length and Temperature specifications are provided in Metric and Celsius units

Page 50: Fourier systems products catalog

www.fouriersystems.com

Notes

Specifications48

Page 51: Fourier systems products catalog

© 2009 Fourier Systems Ltd. All rights reserved. Fourier Systems Ltd. logos and all other Fourier product or service names are registered trademarks ortrademarks of Fourier Systems. All other registered trademarks belong to their respective companies. P/N 11611, Rev. 2/09.

Committed to Qual i ty

Page 52: Fourier systems products catalog

www.fouriersystems.com

Committed to Qual i ty