four tcr & four tcrh...19.5 2/2 635 tcr-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 tcr-108 16500...
TRANSCRIPT
![Page 1: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/1.jpg)
FOUR TCR & FOUR TCRHTropical Rooftop & Heat-Pump Rooftop
is a registered trademark ofDoğu İklimlendirme A.Ş.
![Page 2: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/2.jpg)
DOGU HVAC founded in 1999, and ever since has been manufacturing Energy-and Cost-Efficient products as Air Handling Units, Air Distribution & Management & Movement Systems [HVAC Components] and constantly enhancing to provide an integrated solution for well-being. DOGU HVAC's core business products which are subsumed under 4 major groups as Air Handling Units, Heat/Energy Recovery Units, Air Distribution & Management Products and Kitchen Ventilation Equipment are all produced under the compliance with EU standarts. Particularly AHU and HRU-ER units are entitled under the "FOUR SEASONS" brand name for domestic and foreign markets. DOGU HVAC's, headquarter in Izmir/Turkey, operates in a large-sized plant spread over 2 factories, in total area of 45,000 sqm. in which 25,000 sqm. indoor space that enables DOGU HVAC manufactures 140 various type of products. Additionally, DOGU HVAC has a powerful sales network with 3 sales offices located in Istanbul, Ankara and Antalya in Turkey as well as authorized dealers in many other countries for sales and after sales operations. DOGU HVAC has been exporting to more than 50 countries.
Thanks to our "Customer Satisfaction","Zero-Defect Policy" motto and reinforced by complete certified products, more than 250 employees. DOGU HVAC R&D center developed exclusive products, such as Double Skin Make-Up Kitchen Hood, Recirculated Laminar Airflow Unit, Single Piece Square Ceiling Diffuser and Ecology Units, for the first time have brought to the sector. DOGU HVAC R&D has the ability to make customized production which can meet the requirement of the customers by means of special software such as "ANSYS FLUENT". DOGU HVAC guaranteed its quality of management by having advantages of ISO 9001, ISO 14001, ISO 18001 certifications. Air Handling Units have EUROVENT, TUV Hygiene [in accordance with DIN1946-4, VDI 6022-1, DIN EN 13053 standarts], CE, TSEK, GOST-R certifications; Fire Dampers have EN 1366-2 and EN 13501-3 CE certifications; Smoke Control Dampers have EN 1366-10 and 12101-8 CE certifications; Kitchen Ventilation Products have TSE, CE and GOST-R quality certifications.
Venues Breathe with DOGU HVAC Systems!
![Page 3: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/3.jpg)
FOUR TCR & FOUR TCRH / Tropical Rooftop & Heat-Pump Rooftop
*DOĞU HVAC reserves the right to change specifications without notice. www.doguhvac.com 1
14 Different Models for FOUR-TCR & FOUR TCRHRooftop Packaged Air ConditionersOptional Only Cooling or Heat-Pump SystemsDifferent Range for Different Air Climates
Optimal Energy Efficiency, Air Quality and Comfort
Wide and Versatile Range
Energy Saving Solutions for All Commercial Buildings
These are roof type (ROOFTOP) package air conditioners that can work only cooling or reversible with the direct expansion refrigerant system, cool the place air with the Cooling / DX battery in the summer and heat it in the winter. It provides the conditioning of the air inside the place by ducts, which will meet the fresh air requirement it needs and can perform all heating, cooling and ventilation processes in a compact unit. FOUR TCR is designed for climates that need cooling only (Tropical), and FOUR TCRH series is designed for areas that need heating and cooling. It is offered with many capacity options according to the size of the environment to be air-conditioned.
It has high energy efficiency and is budget friendly with fast and easy installation, low operating and initial investment cost. Its main areas of usage are that large commercial buildings, business centers, airports, restaurants, large stores, cinema and theatre halls, conference halls, industrial buildings and centers of logistic.
Compactness with Well Qualified Air
High Energy Efficient Packaged Air Conditioners
Eco-Friendly R410A Refrigerant Gas
Advanced Microprocessor Control Options
Easy Maintenance and Installation
Air Conditioning Solutions
GENERAL SPECIFICATIONS
COMPONENTS
Supply Fan
Economizer
ExpansionValve
CondenserFan
ElectricalPanel
CondenserCoil
CompressorEvaporatorCoil
CondenserCoil
![Page 4: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/4.jpg)
www.doguhvac.com2 *DOĞU HVAC reserves the right to change specifications without notice.
High efficient and low noise centrifugal fans
Compact design
Full integrated control system
Plug&Play
FOUR TCR & FOUR TCRH
Economizer
Bag filter chamber
Electric heater
Heating coil
Cooling coil
Coil coating
Electronic expansion valve
Dirty filter sensor
CO sensor
Enthalpy control
Condenser fan speed control
Smoke detector
OPTIONS
AIR CONFIGURATION
High efficiency
Quite operation, low sound levels
Fewer moving parts
Compact and light design
Crank case heater
COMPRESSOR
Copper pipe-aluminum fin exchanger
High temperature and humidity efficiency
HEAT EXCHANGER COIL
Large filtering area for energy efficiency and long service period
High efficiency ISO Course filters
FILTER
Galvanized sheet with electrostatic powder paint
Insulated with 19 mm rubber
Easy maintainability and serviceability
CASE
OPERATING LIMITS
SupplyAir
ReturnAir
COOLING
Minimum
Average
Maximum
15
35
52
7
24
27
18
27
36
14
19
24
Outdoor Air TemperatureDry Bulb
°C °C °C °C
Wet Bulb Dry Bulb Wet BulbIndoor Air Temperature
HEATING
Minimum
Average
Maximum
-5
7
24
3
6
22
18
27
36
14
19
24
Outdoor Air TemperatureDry Bulb
°C °C °C °C
Wet Bulb Dry Bulb Wet BulbIndoor Air Temperature
FOUR TCR & FOUR TCRH / Tropical Rooftop & Heat-Pump Rooftop
²
![Page 5: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/5.jpg)
www.doguhvac.com 3*DOĞU HVAC reserves the right to change specifications without notice.
FOUR TCR Series Technical Data
NOTES:(1) Capacities as per of EN 14511 @ 27/19 °C coil inlet and 35 °C ambient temperature.(2) Capacities @ 27/19 °C Coil inlet and 46 °C ambient temperature.(2) Maximum ESP at nominal airflow rate for high pressure class units.
Airflow Rate
(1)Total Cooling Capacity
(1)Sensible Cooling Capacity
(2)Total Cooling Capacity
(2)Sensible Cooling Capacity
Total Absorbed Power (High)
Fan Motor Absorbed Power
Total Compressor Absorbed Power
Compressor / Circuit Number
(3)Max. External Static Pressure
Energy
Refrigerant
m³/h
kW
pcs.
Pa
TCR-18
2850
19
14
17
13
7.1
0.8
4.8
1/1
524
TCR-23
3600
24
18
22
17
8.6
1.1
5.9
1/1
538
TCR-32
4800
33
24
29
23
12.8
1.5
7.7
1/1
621
TCR-37
5650
38
28
34
26
14.1
1.5
9.5
2/2
504
TCR-47
7250
48
36
44
34
16.7
2.2
11.6
2/2
594
TCR-64
9400
65
48
58
45
24.6
3
15,4
2/2
596
TCR-72
10750
73
54
67
51
26.3
3
17.5
2/2
486
018 - 072
380-400 V / 3 ph. / 50 Hz.
R410A
Airflow Rate
(1)Total Cooling Capacity
(1)Sensible Cooling Capacity
(2)Total Cooling Capacity
(2)Sensible Cooling Capacity
Total Absorbed Power (High)
Fan Motor Absorbed Power
Total Compressor Absorbed Power
Compressor / Circuit Number
(3)Max. External Static Pressure
Energy
Refrigerant
m³/h
kW
pcs.
Pa
TCR-80
12200
81
60
75
60
29.9
4
19.5
2/2
635
TCR-94
14100
95
70
86
66
33.6
5.5
22.7
2/2
710
TCR-108
16500
109
82
99
77
40.6
5.5
26.5
2/2
625
TCR-122
18750
123
92
113
87
47.5
5.5
30.2
2/2
554
TCR-138
21150
139
104
129
98
54.7
7.5
34.7
2/2
771
TCR-154
23750
155
116
142
109
58.8
7.5
39.1
2/2
554
TCR-176
27100
177
133
159
125
69
11
44.4
2/2
623
080 - 176
380-400 V / 3 ph. / 50 Hz.
R410A
L W
H
FOUR TCR & FOUR TCRH / Tropical Rooftop & Heat-Pump Rooftop
![Page 6: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/6.jpg)
www.doguhvac.com4 *DOĞU HVAC reserves the right to change specifications without notice.
FOUR TCRH Series Technical Data
NOTES:(1) Capacities @ 27/19 °C coil inlet and 35 °C ambient temperature.(2) Capacities @ 21/15,5 °C coil inlet and 7 °C ambient temperature.(3) Capacities @ 27/19 °C coil inlet and 46 °C ambient temperature.(4) Capacities @ 21/15,5 °C coil inlet and -5 °C ambient temperature.(5) Maximum ESP at nominal airflow rate for high pressure class units.
Airflow Rate
(1)Total Cooling Capacity
(1)Sensible Cooling Capacity
(2)Total Heating Capacity
(2)Sensible HeatingCooling Capacity
(3)Total Cooling Capacity
(3)Sensible Cooling Capacity
(4)Total Heating Capacity(4)Sensible Heating Capacity
Total Absorbed Power (High)
Fan Motor Absorbed Power
Total Compressor Absorbed Power
Compressor / Circuit Number(5)Max. External Static Pressure
Energy
Refrigerant
m³/h
kW
pcs.
Pa
TCRH-18
2850
19
15
20
15
17
14
15
11
7
0.8
4.8
1/1524
TCRH-23
3600
24
19
25
19
22
17
19
14
8.5
1.1
5.9
1/1538
TCRH-32
4800
33
25
33
25
29
23
25
19
12.7
1.5
7.7
1/1621
TCRH-37
5650
38
30
39
30
35
27
30
22
14.2
1.5
9.5
2/2504
TCRH-47
7250
49
38
50
38
44
34
37
28
16.6
2.2
11.6
2/2594
TCRH-64
9400
65
51
66
50
58
46
49
37
24.7
3
15.4
2/2596
TCRH-72
10750
75
59
77
58
67
53
57
43
26.4
3
17.5
2/2486
018 - 072
380-400 V / 3 ph. / 50 Hz. R410A
Airflow Rate
(1)Total Cooling Capacity
(1)Sensible Cooling Capacity
(2)Total Heating Capacity
(2)Sensible HeatingCooling Capacity
(3)Total Cooling Capacity
(3)Sensible Cooling Capacity
(4)Total Heating Capacity(4)Sensible Heating Capacity
Total Absorbed Power (High)
Fan Motor Absorbed Power
Total Compressor Absorbed Power
Compressor / Circuit Number(5)Max. External Static Pressure
Energy
Refrigerant
m³/h
kW
pcs.
Pa
TCRH-80
12200
83
65
85
64
74
58
63
48
29.8
4
19.5
2/2635
TCRH-94
14100
96
75
99
75
87
68
74
55
33.8
5.5
22.7
2/2710
TCRH-108
16500
114
89
117
88
103
80
87
65
40.5
5.5
26.5
2/2625
TCRH-122
18750
128
100
131
98
115
89
98
73
47.3
5.5
30.2
2/2
554
TCRH-138
21150
141
110
144
108
126
99
107
80
54.6
7.5
34.7
2/2
771
TCRH-154
23750
157
123
161
121
141
110
120
90
58.6
7.5
39.1
2/2
554
TCRH-176
27100
178
138
182
137
160
124
135
101
69.1
11
44.4
2/2
623
080 - 176
380-400 V / 3 ph. / 50 Hz. R410A
FOUR TCR & FOUR TCRH / Tropical Rooftop & Heat-Pump Rooftop
![Page 7: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/7.jpg)
www.doguhvac.com 5*DOĞU HVAC reserves the right to change specifications without notice.
NOTE:*All dimensions are in mm.
**All dimensions are approximative.
DIMENSIONS
L W
H
PRODUCT CODE
FOUR TCR / TCRH-018
FOUR TCR / TCRH-023
FOUR TCR / TCRH-032
FOUR TCR / TCRH-037
FOUR TCR / TCRH-047
FOUR TCR / TCRH-064
FOUR TCR / TCRH-072
FOUR TCR / TCRH-080
FOUR TCR / TCRH-094
FOUR TCR / TCRH-108
FOUR TCR / TCRH-122
FOUR TCR / TCRH-138
FOUR TCR / TCRH-154
FOUR TCR / TCRH-176
L
1846
1846
1926
2210
2360
2360
2700
2700
2950
3210
3350
3500
3500
3900
W
1130
1130
1130
1300
1490
1860
1860
2020
2160
2160
2160
2170
2280
2280
H
1442
1592
1708
1780
1820
1860
1960
1980
2070
2154
2364
2400
2400
2500
PRODUCT NAME
Tropical Rooftop/ Heat-Pump Rooftop-018
Tropical Rooftop / Heat-Pump Rooftop-023
Tropical Rooftop / Heat-Pump Rooftop-032
Tropical Rooftop / Heat-Pump Rooftop-037
Tropical Rooftop / Heat-Pump Rooftop-047
Tropical Rooftop / Heat-Pump Rooftop-064
Tropical Rooftop / Heat-Pump Rooftop-072
Tropical Rooftop / Heat-Pump Rooftop-080
Tropical Rooftop / Heat-Pump Rooftop-094
Tropical Rooftop / Heat-Pump Rooftop-108
Tropical Rooftop / Heat-Pump Rooftop-122
Tropical Rooftop / Heat-Pump Rooftop-138
Tropical Rooftop / Heat-Pump Rooftop-154
Tropical Rooftop / Heat-Pump Rooftop-176
FOUR TCR & FOUR TCRH / Tropical Rooftop & Heat-Pump Rooftop
![Page 8: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/8.jpg)
www.doguhvac.com6 *DOĞU HVAC reserves the right to change specifications without notice.
NOTES:(1) Capacities @ 27/19 °C coil inlet and 35 °C ambient temperature.(2) Capacities @ 21/15,5 °C coil inlet and 7 °C ambient temperature.(3) Capacities @ 27/19 °C coil inlet and 46 °C ambient temperature.(4) Capacities @ 21/15,5 °C coil inlet and -5 °C ambient temperature.(5) Maximum ESP at nominal airflow rate for high pressure class units.
Coils are Eurovent certified.
Coils are made of copper pipes and aluminum fins.
The cassette material is galvanized or stainless steel.
The coils were tested at a pressure of at least 20 bar. On request, 30 bars can be tested under pressure.
The collectors used in the coils are copper pipes.
In hot and cold water coils, the water inlet is from the bottom and the water outlet is at the top.
Air and water flows are counter-flowing to increase the heat transfer between them.
Under the cooling coil, a condensate pan with a double slope is placed and the accumulated water is discharged through the drain pipe. In the case of a Drip Holder, a high-performance drill holder made of PVC material that can with stand up to 90° C is used.
HEATING COIL
ELECTRIC HEATER
Rectangular electric heaters have two thermostats as standard.
The first thermostat is set to 70° C, the air in the electric heater cuts off the electric current when it reaches 70° C, allowing the device to restart automatically when the temperature drops.
The second thermostat used for safety purposes is activated at 110° C and cuts off the electric current.
The thermostat must be reset manually from the red button in order for the appliance to operate again.
MODELS
FOUR TCR/TCRH-18FOUR TCR/TCRH-23FOUR TCR/TCRH-32FOUR TCR/TCRH-37FOUR TCR/TCRH-47FOUR TCR/TCRH-64FOUR TCR/TCRH-72FOUR TCR/TCRH-80FOUR TCR/TCRH-94
FOUR TCR/TCRH-108FOUR TCR/TCRH-122FOUR TCR/TCRH-138FOUR TCR/TCRH-154FOUR TCR/TCRH-176
DIMENSIONS
800*572800*572800*762970*762
1160*7621520*8261520*8891680*889
1680*10161730*11431730*13341870*13971980*13971980*1651
T=5
kW6689
12151820252733364248
T=10
kW9
12162024333642485763728193
AIR FLOW(m³/h)
280036004750560072009300
1080012100140001660018800212002370027000
FOUR TCR & FOUR TCRH / Tropical Rooftop & Heat-Pump Rooftop
![Page 9: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/9.jpg)
www.doguhvac.com7 *DOĞU HVAC reserves the right to change specifications without notice.
NOTES
FOUR TCR & FOUR TCRH / Tropical Rooftop & Heat-Pump Rooftop
![Page 10: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/10.jpg)
www.doguhvac.com 8*DOĞU HVAC reserves the right to change specifications without notice.
NOTES
FOUR TCR & FOUR TCRH / Tropical Rooftop & Heat-Pump Rooftop
![Page 11: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/11.jpg)
![Page 12: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/12.jpg)
We make the difference with140 different types of products.
![Page 13: FOUR TCR & FOUR TCRH...19.5 2/2 635 TCR-94 14100 95 70 86 66 33.6 5.5 22.7 2/2 710 TCR-108 16500 109 82 99 77 40.6 5.5 26.5 2/2 625 TCR-122 18750 123 92 113 87 47.5 5.5 30.2 2/2 554](https://reader033.vdocuments.mx/reader033/viewer/2022060904/609fbc5e1683ce54c4384253/html5/thumbnails/13.jpg)
0304
2020
[email protected] | www.doguhvac.com
HeadquarterITOB Organize Sanayi Bölgesi 10010 Sk.No: 4 35477 Tekeli, Menderes, İzmir/TURKEY Теl.: +90 232 799 02 40 | Fax: +90 232 799 02 44
Istanbul Sales OfficeBarbaros Mah. Ciğdem Sk. No: 1 Ağaoğlu My OfficeKat: 4/18 Ataşehir, Istanbul/TURKEYТеl.:+90 216 250 55 45 | Fax:+90 216 250 55 56