for your independence

2
NU-RC300 | 300 W For your independence Take advantage of solar panels + battery solutions for maximum independence 55 years of solar expertise Guaranteed positive power tolerance (0/+5 %) Made in Germany Top PV brand award Proven Quality VDE (IEC/EN 61215, IEC/EN61730) Safety Class II / CE MCS accredited product ISO 9001 / ISO 14001 Monocrystalline silicon photovoltaic modules Product guarantee Linear power output guarantee 18.3 % module efficiency Robust product design (PID resistance) The high performer (RC) 300 W Mono

Upload: others

Post on 17-Jun-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: For your independence

NU-RC300 | 300 W

For your independenceTake advantage of solar panels + battery

solutions for maximum independence

55 years of solar expertise

Guaranteed positive power tolerance (0/+5 %)

Made in Germany

Top PV brand award

Proven Quality VDE (IEC/EN 61215, IEC/EN61730) Safety Class II / CE MCS accredited product ISO 9001 / ISO 14001

Monocrystalline silicon photovoltaic modules

Product guarantee

Linear power output guarantee

18.3 % module efficiency

Robust product design (PID resistance)

The high performer (RC)

300 WMono

Page 2: For your independence

Not

e: T

echn

ical

dat

a is

sub

ject

to

chan

ge w

ithou

t pr

ior

notic

e. B

efor

e us

ing

Shar

p pr

oduc

ts,

plea

se r

eque

st t

he la

test

dat

a sh

eets

fro

m S

harp

. Sh

arp

acce

pts

no r

espo

nsib

ility

for

dam

age

to d

evic

es w

hich

hav

e be

en e

quip

ped

with

Sha

rp p

rodu

cts

on t

he b

asis

of

unve

rifie

d in

form

atio

n.

The

spec

ifica

tions

may

dev

iate

slig

htly

and

are

not

gua

rant

eed.

Inst

alla

tion

and

oper

atin

g in

stru

ctio

ns a

re to

be

foun

d in

the

corr

espo

ndin

g ha

ndbo

oks,

or c

an b

e do

wnl

oade

d fr

om w

ww

.sha

rp.e

u/so

lar.

Thi

s m

odul

e sh

ould

not

be

dire

ctly

con

nect

ed to

a lo

ad.

NUR

C30_

07/1

6EN

www.sharp.eu

Empower yourself Contact Sharp SHARP ENERGY SOLUTIONS EUROPEA DIVISION OF SHARP ELECTRONICS (EUROPE) LTD.SONNINSTR.320097 HAMBURGGERMANYT: +49(0)40/2376-2436F: +49(0)40/2376-2193

Contact Installer

NU-RC300

Maximum power Pmax 300 Wp

Open-circuit voltage Voc 39.4 V

Short-circuit current Isc 9.97 A

Voltage at point of maximum power Vmpp 31.2 V

Current at point of maximum power Impp 9.63 A

Module efficiency m 18.3 %

STC = Standard Test Conditions: irradiance 1,000 W/m², AM 1.5, cell temperature 25 °C. Rated electrical characteristics are within ±10 % of the indicated values of Isc, Voc and 0 to +5 % of Pmax (power measurement tolerance ±3 %). Reduction of efficiency from an irradiance of 1,000 W/m² to 200 W/m² (Tmodule = 25 °C) is less than 2 %.

NU-RC300

Maximum power Pmax 220 Wp

Open-circuit voltage Voc 36.3 V

Short-circuit current Isc 8.07 A

Voltage at point of maximum power Vmpp 28.5 V

Current at point of maximum power Impp 7.72 A

Module efficiency m 16.7 %

Electrical values measured under nominal operating conditions of cells : 800 W/m² irradiance, air temperature of 20 °C, wind speed of 1 m/s. NOCT : 48 °C (nominal operating cell temperature).

Electrical data (NOCT)

Electrical data (STC)

Cells monocrystalline, 156 mm × 156 mm, 60 cells in series

Front glass low iron tempered glass, 3.2 mm

Frame anodized aluminium alloy, silver

Connection box PPE/PPO resin, IP67 Rating, 148 x 123 x 27 mm, 3 bypass diodes

Cable CE cable, length 1,200 mm (+), 800 mm (-)

Connector MC4

Modules per pallet 22 pcs

Pallet size (L × W × H) 1.2 m × 1.0 m × 1.85 m

Pallet weight approx. 477 kg

Modules packed in one carton 22 pcs

Packaging dataGeneral data

Length 1,660 mm

Width 990 mm

Depth 50 mm

Weight 20 kg

Pmax -0.40 %/°C

Voc -0.29 %/°C

Isc 0.05 %/°C

Mechanical data

Temperature coefficient

Dimensions (mm)

*Please refer to Sharp’s installation manual for details.

Maximum system voltage 1,000 V

Over-current protection 20 A

Temperature range -40 bis 85° C

Max. mechanical load (snow / wind) 2,400 Pa

Tested snow load (IEC61215 test pass*) 5,400 Pa

Limit values

95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990 95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990 95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990 95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990 95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990 95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990

95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

99095050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

99095050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990 95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990 95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990

95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990 95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990

95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990

95050

1660

100

100

1460

430

430

800

800 (-)

1200 (+)

990

Local responsibility: Benelux [email protected], France [email protected], Germany [email protected], Poland [email protected] & Portugal [email protected], United Kingdom [email protected], Other countries [email protected]