for informationf +27 21 426 1324 e [email protected] general notes: 1) all pedestrian ramps to be...
TRANSCRIPT
Insitu Concrete footing
to protrude 50mm above
ground
10 mm chamfer edge
Joint edge detail 1 SCALE 1:2
Lawn (Refer to landscape
schedule)
Galvanized steel legs to
be filled with concrete
220 x 220 Insitu concrete base
to Eng. detail with 10 mm
chamfer edge
8 mm dia perforated
galvanized steel sheet bin
Bin concrete footing detail SCALE 1:25
220330220
400
110
110
Grass (Refer
to landscape
schedule)
Centre line
220
8 mm diameter perforated
galvanized steel sheet bin
Cast-in plate 150 x 150 x 8
thick
Insitu concrete base to
Eng. detail
Galvanized steel legs to
be filled with concrete
220
50 50
560
760
200
200
960
500
400
DETAIL 1
20 mm diameter fixed attachment
point
ce
ntre
lin
e
220
110 110
Lawn (Refer to landscape
schedule)
Typical section SCALE 1:10
L i t t e r b i n d e t a i l
110 110
330
TOP OF PAVERS
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
A JN Issued for Information
Bin Detail
07 May 2019
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
BHBRP 2211 C 501
2019.06.19 As shown
Heritage Landscape and Public
Environment Upgrade
DESIGNED BYA. L
CHECKED BYA. L
FOR INFORMATION
B JN Tender Issue19 June 2019
200
1400100 100
Insitu concrete base
to eng. detail
450
Bench edges to be chamfered
at 45° right all around
1600
DETAIL 1
Finish: Smooth natural grey finish
6 B
rick W
idths (no cutting)
660
line of concrete bench slab above
line of concrete bench slab above
500
80
80
1210 (11 Brick widths) 330 ( 3 x brick widths)
13510095
110 (1x Brick Width)
220
Concrete bench leg
330 ( 3 x brick widths)
135 100 95
Insitu concrete base
with 10 mm chamfer
edge to eng. detail
centre line
Clay pavers (220x110x50)
Typical section SCALE 1:10
Plan SCALE 1:10
C o n c r e t e b e n c h d e t a i l
100
Reinforced concrete bench
135 100 95
1210 (11 Brick widths)330 ( 3 x brick widths) 331 ( 3 x brick widths)
Top of pavers
Clay pavers (220x110x50)
Insitu Concrete footing
Bedding sand
10 mm chamfer edge
Pavers
Joint edge detail 1 SCALE 1:2
Cement grouting
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
Bench Detail
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
BHBRP 2211 C 502
2019.06.19 As shown
Heritage Landscape and Public
Environment Upgrade
DESIGNED BYA. L
CHECKED BYA. L
A JN Issued for Information07 May 2019
FOR INFORMATION
B JN Tender Issue19 June 2019
220022002200
centre line of structure
450
1750 (16 x brick width)
450
450
450
eq
eq
centre line of structure
centre line of structure
centre line of structure
centre line of structure
Roof to fall 5°
7200
2500
ROOF SHEETING:
0.58 mm Galvanised Z200 valley gutter, colour to
match roof sheeting
Corrugated sheeting 0.58mm @ 5°ROOF SLOPE.
Chromadek finish: Dark Dolphin
900
1600
Roof to fall 5°
FALL 1:100FALL 1:100
Elevation 1, refer to drawing no. C509.1
Roof level SCALE 1:50
203 x 203 H-column
450 x 450 RC plinth to
eng's specs and details
A
A
Roof line above
Gutter box and 75 x 100 rectangular downpipe at both
ends, colour to match roof sheeting.
1750 (16 x brick width)
450
1750 (16 x brick width)
450
900
1600
2500
203 x 203 H-column 203 x 203 H-column 203 x 203 H-column
Roof line above
Seating level SCALE 1:50
Plinth level SCALE 1:50
8 mm thick shaped m/steel
seat side supports, bolted to
steel columns to Engineer's
specs and details
102mm Ø m/steel chs back
support to be welded or bolted
to steel columns.
3 x 60mm Ø m/steel chs for
seat to be welded to shaped
steel plate.
centre line of structure
300300
B100 mentis grating 'gripweld' or similar
with 25x4.5mm bearer bars, fixed to
50x50x2.5mm steel shs surround frame.
75x100 cut out into H-beam for rainwater goods
Roof line above
Roof line above
790
60
380
2032 2032 2032
Refer to drawing no. C504.1
Refer to drawing no. C504.1
Elevation 3, refer to drawing no. C504.2
Elevation 2, refer to
drawing no. C504.2
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
Bus Shelter
Details 1 of 3
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
C 503.0
As shown
DESIGNED BYA. L
CHECKED BYA. L
B
HBRP 2211
2019.06.19
Heritage Landscape and Public
Environment Upgrade
A JN Issued for Information07 May 2019
FOR INFORMATION
B JN Tender Issue19 June 2019
Section A-A SCALE 1:25
203 x 203 m/steel H- column to
be used as roof support /
gutter. Sizes and details to
engineer's specs.
Clay pavers on bedding sand
and paving layerworks to
engineer's specs and detail
203 x 203 m/steel H-column
welded to base plate and bolted
to r.c footing to eng's. details and
specs
IPE 200 rafter cut to shape to
eng's specs and details
1600900
5° roof angle
COLOUR FINISH: ALL STEEL WORKS
TO BE PAINTED AND COLOUR : RAL
7011 (IRON GREY).
Cap plate welded to top of colum to
engineers specs and details
0.58 mm Galvanised Z200
valley gutter, colour to match
roof sheeting on
Elevation 1
75 x 50 x 20 C channel purlin and
spacing to eng's specs and details
Top of paver
2500
450
Conc footing to eng's specs and
details
2600
50
790
600
300
8 mm thick shaped m/steel side
supports, bolted to steel columns to
Engineer's specs and details
102mm Ø m/steel chs back support
to be welded or bolted to steel
columns.
3 x 60mm Ø m/steel chs for seat to
be welded to shaped steel plate.
244 343
125 125
B100 mentis grating 'gripweld' or
similar with 25x4.5mm bearer
bars, fixed to 50x50mm steel shs
surround frame.
50x50mm steel shs surround
frame.
8 mm thick shaped m/steel seat
side supports, bolted to steel
columns to Engineer's specs and
details
Corrugated sheeting 0.58mm @
5°ROOF SLOPE. Chromadek
finish: Dark Dolphin
203
Elev. 3
200
145
203 x 203 m/steel H- column to be used as roof support
/ gutter. Sizes and details to engineer's specs.
Clay pavers on bedding
sand and paving
layerworks to engineer's
specs and detail
203 x 203 M/steel
H-column welded to base
plate and bolted to r.c
footing to eng's. details
and specs
Conc footing to eng's
specs and details
Elevation 1 SCALE 1:50
Top of pavers ± 0,000
220022002200 300300
7200
A
A
2600
50
75 x 100 rectangular
downpipe at both ends ,
colour to match roof
sheeting.
600
300
ROOF SHEETING:
Corrugated sheeting 0.58mm @ 5°ROOF SLOPE.
Chromadek finish: Dark Dolphin
Seating Level + 0,600
102mm Ø m/steel chs
back support to be
welded or bolted to steel
columns.
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
C 503.1
As shown
DESIGNED BYA. L
CHECKED BYA. L
B
HBRP 2211
2019.06.19
Heritage Landscape and Public
Environment Upgrade
Bus Shelter
Details 2 of 3
A JN Issued for Information07 May 2019
FOR INFORMATION
B JN Tender Issue19 June 2019
203 x 203 m/steel H- column to be used as roof support
/ gutter. Sizes and details to engineer's specs.
203 x 203 M/steel
H-column welded to base
plate and bolted to r.c
footing to eng's. details
and specs
Conc footing to eng's
specs and details
Elevation 3 SCALE 1:50
Top of pavers ± 0,000
220022002200 300300
7200
50
75 x 100 rectangular
downpipe at both ends ,
colour to match roof
sheeting.
2600
ROOF SHEETING:
Corrugated sheeting 0.58mm @ 5°ROOF SLOPE.
Chromadek finish: Dark Dolphin
1849
B100 mentis grating 'gripweld'
or similar with 25x4.5mm
bearer bars, fixed to
50x50x2.5mm steel shs
surround frame.
2032
50
Final paint finish: Bitiminous Aluminium
paint to Mentis grating only
Elevation 2 SCALE 1:25
5mm thk end cap m/s plate to
to both ends of H-Beam
Clay pavers on bedding sand
and paving layerworks to
engineer's specs and detail
203 x 203 m/steel H-column
welded to base plate and bolted
to r.c footing to eng's. details and
specs
IPE 200 rafter cut to shape to
eng's specs and details
1600900
5° roof angle
COLOUR FINISH: ALL STEEL WORKS
TO BE PAINTED AND COLOUR : RAL
7011 (IRON GREY).
Elevation 1
75 x 50 x 20 C channel purlin and
spacing to eng's specs and details
Top of paver
2500
2600
50
8 mm thick shaped m/steel side
supports, bolted to steel columns to
Engineer's specs and details
244 343
8 mm thick shaped m/steel seat
side supports, bolted to steel
columns to Engineer's specs and
details
Corrugated sheeting 0.58mm @
5°ROOF SLOPE. Chromadek
finish: Dark Dolphin
203
Elev. 3
200
145
300200
Bigger side panel: 330 x 1670 x
15 mm thk min clear perspex
fixed with flat steel patch fittings.
1670
Small side panel: 1670 x 200 Steel
sheet fixed with flat steel patch
fittings. Thickness to be a min of 16
mm.
75 x 100 rectangular
downpipe at both
ends , colour to match
roof sheeting.
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
C 503.2
As shown
DESIGNED BYA. L
CHECKED BYA. L
B
HBRP 2211
2019.06.19
Heritage Landscape and Public
Environment Upgrade
Bus Shelter
Details 3 of 3
A JN Issued for Information07 May 2019
FOR INFORMATION
B JN Tender Issue19 June 2019
30
00
330 x 220 conc footing
detail by electrical engineer
eq
eq
PEDESTRIAN LIGHT
BEKA LEDSHINE : LED Version
MOUNTING : Post mounted.
Mounting height 3.5 metres max.
Colour Standard Grey (RAL 7045), Textured finish
CB
CC CB
CCC
500
330
220
eq
eq
220
440
2200
220
330 x 220 conc footing
CB
Corobrik Burgundy clay paving brick, size:220 x
110mm x 50mm. Colour type: RED.
CC
Corobrik Cederberg clay paving brick, size:220 x
110mm x 50mm. Colour type: RED. (Herringbone
pattern)
CCC
Standard Concrete / Clay Cobble 110 x110 x 50 mm
at 6.05 metres spacing
Colour type: Charcoal / Onyx
WALKWAY TYPE 1 -
PAVERS SPECIFICATIONS
SECTION A-A
scale 1:20 (Printed at A3)
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.As shown
DESIGNED BYA. L
CHECKED BYA. L
B
HBRP 2211
Heritage Landscape and Public
Environment Upgrade
Pedestrian Light
Detail
A JN Issued for Information07 May 2019
C 504
JN2019.06.19
PLAN
scale 1:20 (Printed at A3)
FOR INFORMATION
B JN Tender Issue19 June 2019
2000
100
1792 100100 100
775
100
1000
100
Note :
The balustrade is designed upon a 2m
centre spacing.
The end balustrade dimension on
each section may vary and is subject
to confirmation by Contractor.
Paving Level
100
60
6mm Thick x 60mm galvanised steel
flat frame surround
8mm Thick x 100mm Wide galvanised
steel flat frame vertical post cast into
R.C.
New galvanised steel balustrade to
specialist manufacture and installation
20mmØ Galvanised steel circular
hollow sections
spaced @ 120mm centres & welded to
frame
6mm Thick x 60mm galvanised steel
flat for horizontal stability
120 120 120 120 120 120 120 120 120 120 120 120 120 110
Centre line
6mm Thick x 60mm galvanised steel
flat frame surround
8mm Thick x 100mm Wide galvanised
steel flat frame vertical post cast into
concrete footing
3.5mm Thick 50mmØ galvanised steel
hollow section handrail
20mmØ Galvanised steel circular
hollow sections spaced @ 120mm
centres & welded to frame
6mm Thick x 60mm galvanised steel
flat for horizontal stability
100 10099
6
688
6
100
6
66
Centre line
6886
66
100
100
100
100
AA
6886
66
100
100
1106
66
100
100
100
Handrail typical
detail elevation
SCALE 1:10
Conc footing as per Structural
Engineer's details & specification
Handrail typical detail plan a-a
SCALE 1:10
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
A JN Issued for Information
Balustrade Detail
- Plan & Elevation
07 May 2019
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
BHBRP 2211 C 505.0
2019.06.19 As shown
Heritage Landscape and Public
Environment Upgrade
DESIGNED BYA. L
CHECKED BYA. L
FOR INFORMATION
B JN Tender Issue19 June 2019
Dry stacked stone retaining wall to be
made good with all foreign plants
removed
100
50
℄
100
775
100
1000
6mm Thick x 60mm galvanised steel
flat frame surround
8mm Thick x 100mm Wide galvanised
steel flat frame vertical post cast into
concrete footing.
3.5mm Thick 50mmØ galvanised steel
hollow section handrail
20mmØ Galvanised steel circular
hollow sections spaced @ 120mm
centres & welded to frame
6
Centre line
6
50
Conc footing as per Structural
Engineer's details & specification
500
500mm min deep extended
balustrade verticals to be cast into
conc footing
Handrail typical detail section thru
existing retaining wall
SCALE 1:10
50 100 50
6mm galvanised steel side plate to be
securely fixed to existing parapet wall
and new vertical.
8mm Thick x 100mm Wide galvanised
steel flat frame vertical post
Existing parapet wall
6mm Thick x 60mm galvanised steel
flat for horizontal stability
100
125
Handrail vertical post connection
detail 1-1
SCALE 1:10
175
Ground cover.
Refer to landscaping specification
Ground cover.
Refer to landscaping
specification
300 x 600 precast concrete paver
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
A JN Issued for Information
Balustrade Detail
- Section
07 May 2019
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
BHBRP 2211 C 505.1
2019.06.19 As shown
Heritage Landscape and Public
Environment Upgrade
DESIGNED BYA. L
CHECKED BYA. L
FOR INFORMATION
B JN Tender Issue19 June 2019
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
123456789
10
11
12
13
14
15
16
17
18
300
170
1530
1530
1800
1800 2400
24001800
STEEL STAIRCASE PLAN
SCALE 1:50
(9
x 1
70
rise
r)
300
STEEL STAIRCASE SECTION B-B
SCALE 1:50
STEEL STAIRCASE SECTION A-A
SCALE 1:50
A
A
B B
200 x 90 PFC
stringer beam
170
1530
1530
(9
x 1
70
rise
r)
200 x 90 PFC
stringer beam
200 x 90 PFC
stringer beam
200 x 90 PFC
column
PROPOSED
Top of Square Landing1753.761
PROPOSED
Top of Square Landing
1753.761
PROPOSED
Top of Square Landing
1753.761
PROPOSED
Top of Landing
1756.821
PROPOSED
Top of Landing
1756.821
200 x 90 PFC
column
(8 x 300 tread)
50mm diameter Steel
hollow section handrail
Line of paving
Lin
e o
f brid
ge a
bove
Lin
e o
f brid
ge a
bove
Line of paving
Balustrade to later detail
(Refer to dwg C505.0
and C505.1)
PROPOSED
Top
of
Square
Landing
1753.761
PROPOSED
Top of Landing
1756.821
Note: All steelwork to be
painted to a later specification
Steel staircase to
connect to existing
concrete bridge
50mm diameter Steel
hollow section handrail
Steel tread
Steel tread
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
B JN Tender Issue
Steel Staircase
Detail
19 June 2019
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
BHBRP 2211 C 506
2019.06.19 As shown
Heritage Landscape and Public
Environment Upgrade
DESIGNED BYA. L
CHECKED BYA. L
FOR INFORMATION
Retaining Wall Detail Section
SCALE 1:10
Coping
600 x 30 x 60 concrete jap slab
DPC
50 x 50 x 400mm (long) dry pack wall
Type of Stone: Slate Rich Autumn
to be laid on
32 x 1.2mm hoop irons
Spaced @ 800mm c/c horizontally and
425mm c/c vertically.
To be bolted (M6 raw bolts) to brick wall
+1200
600
100 280 100
1:50 fall
Mortar infill
+0
Landscaping
50mm diameter PVC weep hole
@ 1500mm c/c
Concrete mass footing
Concrete footing to Engineer's
specification and details
Clay pavers
Sidewalk
Concrete
mass footing
Waterproofing
membrane
Hoop Iron fixing detail
SCALE nts
Concrete footing to Engineer's
specification and details
Concrete footing to Engineer's
specification and details
32 x 1.2mm hoop irons spaced @
800mm c/c horizontally and 425mm c/c
vertically and to be bolted to brick wall
Continuous 32 x 1.2mm hoop iron
running horizontally and to be riveted,
supporting dry stacked stone
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
Retaining Wall
Detail
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
BHBRP 2211 C 507
2019.06.19 As shown
Heritage Landscape and Public
Environment Upgrade
DESIGNED BYA. L
CHECKED BYA. L
FOR INFORMATION
B JN Tender Issue19 June 2019
25x25x4mm galv. m/steel angle brackets
all round, fixed to 70x50mm holsec uprights
70x50mm holsec upright with base plate
concreted in
Vertical gal. mild steel signage
plate fixed to post 70mm wide
100
1400
HE
RIT
AG
E B
US
black enamel paint finish
'HERITAGE BUS'
letters to be
cut out
black enamel paint finish
Vertical galv. mild steel
signage plate 100mm wide on
bothsides, fixed to posts
6,4mm Safety glass signage panel
side fixing only to vertical supports
70x50mm holsec upright with
base plate concreted in.
F.P.L
1800
F.P.L
Concret base for vertical supports
to Str. Eng. details
600
1800
1400
400
paving to spec.
400
1400
black enamel paint finish
Vertical galv. mild steel
signage plate 70mm wide on
bothsides, fixed to posts
50
1350
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aliquam dignissim ex vitaemagna elementum ultricies. In non tempor metus. Nunc tristique magna vestibulum,dignissim sem viverra, tristique leo. Mauris quis diam non dolor accumsan elementum utquis diam. Cras pellentesque gravida purus vel interdum. Cras tincidunt risus vel enimtempor placerat. Donec lacinia ultrices diam, a venenatis eros lacinia eu. Quisque acgravida tortor.
Sed cursus gravida molestie. Aenean id sagittis libero. Cras vel lobortis elit. Suspendisselectus turpis, blandit vitae molestie eget, laoreet ac velit. Praesent ac mauris a nuncvulputate sodales. Ut viverra nibh purus, sed hendrerit elit efficitur sit amet. Morbi metusmauris, ullamcorper vitae consectetur id, sodales id risus. Fusce posuere ut metus abibendum. Maecenas feugiat ligula non tellus condimentum scelerisque. Maecenasluctus, diam et aliquet posuere, justo leo suscipit nisl, ac hendrerit lectus sem id mauris.Integer massa dolor, volutpat interdum faucibus ac, pulvinar nec sem.
black background with white text
Vertical galv. mild
steel signage plate
70mm wide on both
sides, fixed to posts
25x25x4mm galv. m/steel angle
brackets all round, fixed to
70x50mm holsec uprights
6,4mm Safety glass signage panel
side fixing only to vertical supports
70x50mm holsec top rail.
70x50mm holsec bottom rail.
70x50mm holsec top rail.
70x50mm holsec bottom rail.
SIGNAGE BOARD FRONT ELEVATION
SCALE 1:50
SECTION A-A
SCALE 1:50
1000
1350
50
SIGNAGE PLATE
SCALE 1:50
1000
70x50mm galv m/steel holsec
uprights concreted in
Vertical galv. mild steel signage plate
70mm wide on bothsides,
fixed to posts
'DIAGONAL STREET' letters to be
cut out
70
black enamel paint finish
25x25x4mm galv. m/steel angle brackets all round,
fixed to 70x50mm holsec uprights
6,4mm Safety glass signage panel
side fixing only to vertical supports
SIGNAGE BOARD PLAN
SCALE 1:50
FIXING DETAIL PLAN
SCALE 1:25
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
Signage Board
Detail
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
BHBRP 2211 C 508
2019.06.19 As shown
Heritage Landscape and Public
Environment Upgrade
DESIGNED BYA. L
CHECKED BYA. L
FOR INFORMATION
B JN Tender Issue19 June 2019
PLAN
SCALE 1:100
CB
Corobrik Burgundy clay paving brick, size:220 x
110mm x 50mm. Colour type: RED.
CC
Corobrik Cederberg clay paving brick, size:220 x
110mm x 50mm. Colour type: YELLOW.
(Herringbone pattern)
CCC
Standard Concrete / Clay Cobble 110 x110 x 50 mm
at 6.05 metres spacing
Colour type: Charcoal / Onyx
WALKWAY TYPE 1 - PAVERS
SPECIFICATIONS
CC
C
CB
CC
CC
C
220
22
00
220
550
2800
550
existing stone retaining
wall to be made good
and removed all existing
foreign plants
existing stone pillars to
be made good and
removed all existing
foreign plants.
525
New brick steps
to architect's detail
Top of Pavers
1746.500
= + 3.000m
(20x150
risers)
Stone clad retaining wall
to architect's detail
Top of Landing
1748.000
Top of Pavers
1749.658
Clay pavers on bedding sand
and paving layerworks to engineer's
specs and details
Pavers to fall @ 2%
90
SECTION
SCALE 1:50
existing stone pillars to be made
good and removed all existing
foreign plants.
50 x 50 x 400mm (long) dry pack wall
Type of Stone: Slate Rich Autumn
PROPOSED
Top of Landing
1756.821
PROPOSED
Top of Landing
1748.000
Potential position of
heritage blue plaque
to architect's detail
330mm treads
Corobrik Cederburg clay pavers
(220 x 110 x 50)
Hardcore compact filling
to engineer's details and
specifications
Concrete footing to
engineer's details and
specifications
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
150
330
330
330
330
330
330
330
330
330
1320
150
330
330
330
330
330
330
330
330
330
330
3300 1300 3300
Risers at 150mm
Corobrik Cederburg clay
pavers
1200
Dimensions to be
confirmed on site prior to
construction of steps
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
CLIENTARCHITECT
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect
Heritage Gateway
Stairs Detail
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REVISION NUMBER.JN
BHBRP 2211 C 509
2019.06.19 As shown
Heritage Landscape and Public
Environment Upgrade
DESIGNED BYA. L
CHECKED BYA. L
FOR INFORMATION
B JN Tender Issue19 June 2019