for informationf +27 21 426 1324 e [email protected] general notes: 1) all pedestrian ramps to be...

12
Insitu Concrete footing to protrude 50mm above ground 10 mm chamfer edge Joint edge detail 1 SCALE 1:2 Lawn (Refer to landscape schedule) Galvanized steel legs to be filled with concrete 220 x 220 Insitu concrete base to Eng. detail with 10 mm chamfer edge 8 mm dia perforated galvanized steel sheet bin Bin concrete footing detail SCALE 1:25 220 330 220 400 110 110 Grass (Refer to landscape schedule) Centre line 220 8 mm diameter perforated galvanized steel sheet bin Cast-in plate 150 x 150 x 8 thick Insitu concrete base to Eng. detail Galvanized steel legs to be filled with concrete 220 50 50 560 760 200 200 960 500 400 DETAIL 1 20 mm diameter fixed attachment point centre line 220 110 110 Lawn (Refer to landscape schedule) Typical section SCALE 1:10 Litter bin detail 110 110 330 TOP OF PAVERS G A P P architects/urban designers johannesburg 97 second avenue melville 2092 t +27 11 482 1648 f +27 11 482 1216 e [email protected] CLIENT ARCHITECT No. DATE By DESCRIPTION Johannesburg Development Agency cape town 150 longmarket street cape town 8001 t +27 21 424 2390 f +27 21 426 1324 e [email protected] General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways to be flush for disabled access. 3) All road markings to be repainted. 4) All existing traffic signs and light poles to be repaired, painted or replaced where necessary. 5) Final Positions of kerb inlets and pedestrian ramps to be verified on site. If the contractor discovers conflicts between the architectural drawings and the engineers' drawings, he is to contact the architect A JN Issued for Information Bin Detail 07 May 2019 PROJECT DRAWING TITLE DATE JOB NO AUTHOR DRAWING NO. SCALE REVISION NUMBER. JN B HBRP 2211 C 501 2019.06.19 As shown Heritage Landscape and Public Environment Upgrade DESIGNED BY A. L CHECKED BY A. L FOR INFORMATION B JN Tender Issue 19 June 2019

Upload: others

Post on 28-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

Insitu Concrete footing

to protrude 50mm above

ground

10 mm chamfer edge

Joint edge detail 1 SCALE 1:2

Lawn (Refer to landscape

schedule)

Galvanized steel legs to

be filled with concrete

220 x 220 Insitu concrete base

to Eng. detail with 10 mm

chamfer edge

8 mm dia perforated

galvanized steel sheet bin

Bin concrete footing detail SCALE 1:25

220330220

400

110

110

Grass (Refer

to landscape

schedule)

Centre line

220

8 mm diameter perforated

galvanized steel sheet bin

Cast-in plate 150 x 150 x 8

thick

Insitu concrete base to

Eng. detail

Galvanized steel legs to

be filled with concrete

220

50 50

560

760

200

200

960

500

400

DETAIL 1

20 mm diameter fixed attachment

point

ce

ntre

lin

e

220

110 110

Lawn (Refer to landscape

schedule)

Typical section SCALE 1:10

L i t t e r b i n d e t a i l

110 110

330

TOP OF PAVERS

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

A JN Issued for Information

Bin Detail

07 May 2019

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

BHBRP 2211 C 501

2019.06.19 As shown

Heritage Landscape and Public

Environment Upgrade

DESIGNED BYA. L

CHECKED BYA. L

FOR INFORMATION

B JN Tender Issue19 June 2019

Page 2: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

200

1400100 100

Insitu concrete base

to eng. detail

450

Bench edges to be chamfered

at 45° right all around

1600

DETAIL 1

Finish: Smooth natural grey finish

6 B

rick W

idths (no cutting)

660

line of concrete bench slab above

line of concrete bench slab above

500

80

80

1210 (11 Brick widths) 330 ( 3 x brick widths)

13510095

110 (1x Brick Width)

220

Concrete bench leg

330 ( 3 x brick widths)

135 100 95

Insitu concrete base

with 10 mm chamfer

edge to eng. detail

centre line

Clay pavers (220x110x50)

Typical section SCALE 1:10

Plan SCALE 1:10

C o n c r e t e b e n c h d e t a i l

100

Reinforced concrete bench

135 100 95

1210 (11 Brick widths)330 ( 3 x brick widths) 331 ( 3 x brick widths)

Top of pavers

Clay pavers (220x110x50)

Insitu Concrete footing

Bedding sand

10 mm chamfer edge

Pavers

Joint edge detail 1 SCALE 1:2

Cement grouting

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

Bench Detail

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

BHBRP 2211 C 502

2019.06.19 As shown

Heritage Landscape and Public

Environment Upgrade

DESIGNED BYA. L

CHECKED BYA. L

A JN Issued for Information07 May 2019

FOR INFORMATION

B JN Tender Issue19 June 2019

Page 3: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

220022002200

centre line of structure

450

1750 (16 x brick width)

450

450

450

eq

eq

centre line of structure

centre line of structure

centre line of structure

centre line of structure

Roof to fall 5°

7200

2500

ROOF SHEETING:

0.58 mm Galvanised Z200 valley gutter, colour to

match roof sheeting

Corrugated sheeting 0.58mm @ 5°ROOF SLOPE.

Chromadek finish: Dark Dolphin

900

1600

Roof to fall 5°

FALL 1:100FALL 1:100

Elevation 1, refer to drawing no. C509.1

Roof level SCALE 1:50

203 x 203 H-column

450 x 450 RC plinth to

eng's specs and details

A

A

Roof line above

Gutter box and 75 x 100 rectangular downpipe at both

ends, colour to match roof sheeting.

1750 (16 x brick width)

450

1750 (16 x brick width)

450

900

1600

2500

203 x 203 H-column 203 x 203 H-column 203 x 203 H-column

Roof line above

Seating level SCALE 1:50

Plinth level SCALE 1:50

8 mm thick shaped m/steel

seat side supports, bolted to

steel columns to Engineer's

specs and details

102mm Ø m/steel chs back

support to be welded or bolted

to steel columns.

3 x 60mm Ø m/steel chs for

seat to be welded to shaped

steel plate.

centre line of structure

300300

B100 mentis grating 'gripweld' or similar

with 25x4.5mm bearer bars, fixed to

50x50x2.5mm steel shs surround frame.

75x100 cut out into H-beam for rainwater goods

Roof line above

Roof line above

790

60

380

2032 2032 2032

Refer to drawing no. C504.1

Refer to drawing no. C504.1

Elevation 3, refer to drawing no. C504.2

Elevation 2, refer to

drawing no. C504.2

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

Bus Shelter

Details 1 of 3

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

C 503.0

As shown

DESIGNED BYA. L

CHECKED BYA. L

B

HBRP 2211

2019.06.19

Heritage Landscape and Public

Environment Upgrade

A JN Issued for Information07 May 2019

FOR INFORMATION

B JN Tender Issue19 June 2019

Page 4: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

Section A-A SCALE 1:25

203 x 203 m/steel H- column to

be used as roof support /

gutter. Sizes and details to

engineer's specs.

Clay pavers on bedding sand

and paving layerworks to

engineer's specs and detail

203 x 203 m/steel H-column

welded to base plate and bolted

to r.c footing to eng's. details and

specs

IPE 200 rafter cut to shape to

eng's specs and details

1600900

5° roof angle

COLOUR FINISH: ALL STEEL WORKS

TO BE PAINTED AND COLOUR : RAL

7011 (IRON GREY).

Cap plate welded to top of colum to

engineers specs and details

0.58 mm Galvanised Z200

valley gutter, colour to match

roof sheeting on

Elevation 1

75 x 50 x 20 C channel purlin and

spacing to eng's specs and details

Top of paver

2500

450

Conc footing to eng's specs and

details

2600

50

790

600

300

8 mm thick shaped m/steel side

supports, bolted to steel columns to

Engineer's specs and details

102mm Ø m/steel chs back support

to be welded or bolted to steel

columns.

3 x 60mm Ø m/steel chs for seat to

be welded to shaped steel plate.

244 343

125 125

B100 mentis grating 'gripweld' or

similar with 25x4.5mm bearer

bars, fixed to 50x50mm steel shs

surround frame.

50x50mm steel shs surround

frame.

8 mm thick shaped m/steel seat

side supports, bolted to steel

columns to Engineer's specs and

details

Corrugated sheeting 0.58mm @

5°ROOF SLOPE. Chromadek

finish: Dark Dolphin

203

Elev. 3

200

145

203 x 203 m/steel H- column to be used as roof support

/ gutter. Sizes and details to engineer's specs.

Clay pavers on bedding

sand and paving

layerworks to engineer's

specs and detail

203 x 203 M/steel

H-column welded to base

plate and bolted to r.c

footing to eng's. details

and specs

Conc footing to eng's

specs and details

Elevation 1 SCALE 1:50

Top of pavers ± 0,000

220022002200 300300

7200

A

A

2600

50

75 x 100 rectangular

downpipe at both ends ,

colour to match roof

sheeting.

600

300

ROOF SHEETING:

Corrugated sheeting 0.58mm @ 5°ROOF SLOPE.

Chromadek finish: Dark Dolphin

Seating Level + 0,600

102mm Ø m/steel chs

back support to be

welded or bolted to steel

columns.

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

C 503.1

As shown

DESIGNED BYA. L

CHECKED BYA. L

B

HBRP 2211

2019.06.19

Heritage Landscape and Public

Environment Upgrade

Bus Shelter

Details 2 of 3

A JN Issued for Information07 May 2019

FOR INFORMATION

B JN Tender Issue19 June 2019

Page 5: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

203 x 203 m/steel H- column to be used as roof support

/ gutter. Sizes and details to engineer's specs.

203 x 203 M/steel

H-column welded to base

plate and bolted to r.c

footing to eng's. details

and specs

Conc footing to eng's

specs and details

Elevation 3 SCALE 1:50

Top of pavers ± 0,000

220022002200 300300

7200

50

75 x 100 rectangular

downpipe at both ends ,

colour to match roof

sheeting.

2600

ROOF SHEETING:

Corrugated sheeting 0.58mm @ 5°ROOF SLOPE.

Chromadek finish: Dark Dolphin

1849

B100 mentis grating 'gripweld'

or similar with 25x4.5mm

bearer bars, fixed to

50x50x2.5mm steel shs

surround frame.

2032

50

Final paint finish: Bitiminous Aluminium

paint to Mentis grating only

Elevation 2 SCALE 1:25

5mm thk end cap m/s plate to

to both ends of H-Beam

Clay pavers on bedding sand

and paving layerworks to

engineer's specs and detail

203 x 203 m/steel H-column

welded to base plate and bolted

to r.c footing to eng's. details and

specs

IPE 200 rafter cut to shape to

eng's specs and details

1600900

5° roof angle

COLOUR FINISH: ALL STEEL WORKS

TO BE PAINTED AND COLOUR : RAL

7011 (IRON GREY).

Elevation 1

75 x 50 x 20 C channel purlin and

spacing to eng's specs and details

Top of paver

2500

2600

50

8 mm thick shaped m/steel side

supports, bolted to steel columns to

Engineer's specs and details

244 343

8 mm thick shaped m/steel seat

side supports, bolted to steel

columns to Engineer's specs and

details

Corrugated sheeting 0.58mm @

5°ROOF SLOPE. Chromadek

finish: Dark Dolphin

203

Elev. 3

200

145

300200

Bigger side panel: 330 x 1670 x

15 mm thk min clear perspex

fixed with flat steel patch fittings.

1670

Small side panel: 1670 x 200 Steel

sheet fixed with flat steel patch

fittings. Thickness to be a min of 16

mm.

75 x 100 rectangular

downpipe at both

ends , colour to match

roof sheeting.

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

C 503.2

As shown

DESIGNED BYA. L

CHECKED BYA. L

B

HBRP 2211

2019.06.19

Heritage Landscape and Public

Environment Upgrade

Bus Shelter

Details 3 of 3

A JN Issued for Information07 May 2019

FOR INFORMATION

B JN Tender Issue19 June 2019

Page 6: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

30

00

330 x 220 conc footing

detail by electrical engineer

eq

eq

PEDESTRIAN LIGHT

BEKA LEDSHINE : LED Version

MOUNTING : Post mounted.

Mounting height 3.5 metres max.

Colour Standard Grey (RAL 7045), Textured finish

CB

CC CB

CCC

500

330

220

eq

eq

220

440

2200

220

330 x 220 conc footing

CB

Corobrik Burgundy clay paving brick, size:220 x

110mm x 50mm. Colour type: RED.

CC

Corobrik Cederberg clay paving brick, size:220 x

110mm x 50mm. Colour type: RED. (Herringbone

pattern)

CCC

Standard Concrete / Clay Cobble 110 x110 x 50 mm

at 6.05 metres spacing

Colour type: Charcoal / Onyx

WALKWAY TYPE 1 -

PAVERS SPECIFICATIONS

SECTION A-A

scale 1:20 (Printed at A3)

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.As shown

DESIGNED BYA. L

CHECKED BYA. L

B

HBRP 2211

Heritage Landscape and Public

Environment Upgrade

Pedestrian Light

Detail

A JN Issued for Information07 May 2019

C 504

JN2019.06.19

PLAN

scale 1:20 (Printed at A3)

FOR INFORMATION

B JN Tender Issue19 June 2019

Page 7: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

2000

100

1792 100100 100

775

100

1000

100

Note :

The balustrade is designed upon a 2m

centre spacing.

The end balustrade dimension on

each section may vary and is subject

to confirmation by Contractor.

Paving Level

100

60

6mm Thick x 60mm galvanised steel

flat frame surround

8mm Thick x 100mm Wide galvanised

steel flat frame vertical post cast into

R.C.

New galvanised steel balustrade to

specialist manufacture and installation

20mmØ Galvanised steel circular

hollow sections

spaced @ 120mm centres & welded to

frame

6mm Thick x 60mm galvanised steel

flat for horizontal stability

120 120 120 120 120 120 120 120 120 120 120 120 120 110

Centre line

6mm Thick x 60mm galvanised steel

flat frame surround

8mm Thick x 100mm Wide galvanised

steel flat frame vertical post cast into

concrete footing

3.5mm Thick 50mmØ galvanised steel

hollow section handrail

20mmØ Galvanised steel circular

hollow sections spaced @ 120mm

centres & welded to frame

6mm Thick x 60mm galvanised steel

flat for horizontal stability

100 10099

6

688

6

100

6

66

Centre line

6886

66

100

100

100

100

AA

6886

66

100

100

1106

66

100

100

100

Handrail typical

detail elevation

SCALE 1:10

Conc footing as per Structural

Engineer's details & specification

Handrail typical detail plan a-a

SCALE 1:10

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

A JN Issued for Information

Balustrade Detail

- Plan & Elevation

07 May 2019

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

BHBRP 2211 C 505.0

2019.06.19 As shown

Heritage Landscape and Public

Environment Upgrade

DESIGNED BYA. L

CHECKED BYA. L

FOR INFORMATION

B JN Tender Issue19 June 2019

AutoCAD SHX Text
AutoCAD SHX Text
Page 8: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

Dry stacked stone retaining wall to be

made good with all foreign plants

removed

100

50

100

775

100

1000

6mm Thick x 60mm galvanised steel

flat frame surround

8mm Thick x 100mm Wide galvanised

steel flat frame vertical post cast into

concrete footing.

3.5mm Thick 50mmØ galvanised steel

hollow section handrail

20mmØ Galvanised steel circular

hollow sections spaced @ 120mm

centres & welded to frame

6

Centre line

6

50

Conc footing as per Structural

Engineer's details & specification

500

500mm min deep extended

balustrade verticals to be cast into

conc footing

Handrail typical detail section thru

existing retaining wall

SCALE 1:10

50 100 50

6mm galvanised steel side plate to be

securely fixed to existing parapet wall

and new vertical.

8mm Thick x 100mm Wide galvanised

steel flat frame vertical post

Existing parapet wall

6mm Thick x 60mm galvanised steel

flat for horizontal stability

100

125

Handrail vertical post connection

detail 1-1

SCALE 1:10

175

Ground cover.

Refer to landscaping specification

Ground cover.

Refer to landscaping

specification

300 x 600 precast concrete paver

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

A JN Issued for Information

Balustrade Detail

- Section

07 May 2019

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

BHBRP 2211 C 505.1

2019.06.19 As shown

Heritage Landscape and Public

Environment Upgrade

DESIGNED BYA. L

CHECKED BYA. L

FOR INFORMATION

B JN Tender Issue19 June 2019

Page 9: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

123456789

10

11

12

13

14

15

16

17

18

300

170

1530

1530

1800

1800 2400

24001800

STEEL STAIRCASE PLAN

SCALE 1:50

(9

x 1

70

rise

r)

300

STEEL STAIRCASE SECTION B-B

SCALE 1:50

STEEL STAIRCASE SECTION A-A

SCALE 1:50

A

A

B B

200 x 90 PFC

stringer beam

170

1530

1530

(9

x 1

70

rise

r)

200 x 90 PFC

stringer beam

200 x 90 PFC

stringer beam

200 x 90 PFC

column

PROPOSED

Top of Square Landing1753.761

PROPOSED

Top of Square Landing

1753.761

PROPOSED

Top of Square Landing

1753.761

PROPOSED

Top of Landing

1756.821

PROPOSED

Top of Landing

1756.821

200 x 90 PFC

column

(8 x 300 tread)

50mm diameter Steel

hollow section handrail

Line of paving

Lin

e o

f brid

ge a

bove

Lin

e o

f brid

ge a

bove

Line of paving

Balustrade to later detail

(Refer to dwg C505.0

and C505.1)

PROPOSED

Top

of

Square

Landing

1753.761

PROPOSED

Top of Landing

1756.821

Note: All steelwork to be

painted to a later specification

Steel staircase to

connect to existing

concrete bridge

50mm diameter Steel

hollow section handrail

Steel tread

Steel tread

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

B JN Tender Issue

Steel Staircase

Detail

19 June 2019

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

BHBRP 2211 C 506

2019.06.19 As shown

Heritage Landscape and Public

Environment Upgrade

DESIGNED BYA. L

CHECKED BYA. L

FOR INFORMATION

Page 10: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

Retaining Wall Detail Section

SCALE 1:10

Coping

600 x 30 x 60 concrete jap slab

DPC

50 x 50 x 400mm (long) dry pack wall

Type of Stone: Slate Rich Autumn

to be laid on

32 x 1.2mm hoop irons

Spaced @ 800mm c/c horizontally and

425mm c/c vertically.

To be bolted (M6 raw bolts) to brick wall

+1200

600

100 280 100

1:50 fall

Mortar infill

+0

Landscaping

50mm diameter PVC weep hole

@ 1500mm c/c

Concrete mass footing

Concrete footing to Engineer's

specification and details

Clay pavers

Sidewalk

Concrete

mass footing

Waterproofing

membrane

Hoop Iron fixing detail

SCALE nts

Concrete footing to Engineer's

specification and details

Concrete footing to Engineer's

specification and details

32 x 1.2mm hoop irons spaced @

800mm c/c horizontally and 425mm c/c

vertically and to be bolted to brick wall

Continuous 32 x 1.2mm hoop iron

running horizontally and to be riveted,

supporting dry stacked stone

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

Retaining Wall

Detail

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

BHBRP 2211 C 507

2019.06.19 As shown

Heritage Landscape and Public

Environment Upgrade

DESIGNED BYA. L

CHECKED BYA. L

FOR INFORMATION

B JN Tender Issue19 June 2019

Page 11: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

25x25x4mm galv. m/steel angle brackets

all round, fixed to 70x50mm holsec uprights

70x50mm holsec upright with base plate

concreted in

Vertical gal. mild steel signage

plate fixed to post 70mm wide

100

1400

HE

RIT

AG

E B

US

black enamel paint finish

'HERITAGE BUS'

letters to be

cut out

black enamel paint finish

Vertical galv. mild steel

signage plate 100mm wide on

bothsides, fixed to posts

6,4mm Safety glass signage panel

side fixing only to vertical supports

70x50mm holsec upright with

base plate concreted in.

F.P.L

1800

F.P.L

Concret base for vertical supports

to Str. Eng. details

600

1800

1400

400

paving to spec.

400

1400

black enamel paint finish

Vertical galv. mild steel

signage plate 70mm wide on

bothsides, fixed to posts

50

1350

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aliquam dignissim ex vitaemagna elementum ultricies. In non tempor metus. Nunc tristique magna vestibulum,dignissim sem viverra, tristique leo. Mauris quis diam non dolor accumsan elementum utquis diam. Cras pellentesque gravida purus vel interdum. Cras tincidunt risus vel enimtempor placerat. Donec lacinia ultrices diam, a venenatis eros lacinia eu. Quisque acgravida tortor.

Sed cursus gravida molestie. Aenean id sagittis libero. Cras vel lobortis elit. Suspendisselectus turpis, blandit vitae molestie eget, laoreet ac velit. Praesent ac mauris a nuncvulputate sodales. Ut viverra nibh purus, sed hendrerit elit efficitur sit amet. Morbi metusmauris, ullamcorper vitae consectetur id, sodales id risus. Fusce posuere ut metus abibendum. Maecenas feugiat ligula non tellus condimentum scelerisque. Maecenasluctus, diam et aliquet posuere, justo leo suscipit nisl, ac hendrerit lectus sem id mauris.Integer massa dolor, volutpat interdum faucibus ac, pulvinar nec sem.

black background with white text

Vertical galv. mild

steel signage plate

70mm wide on both

sides, fixed to posts

25x25x4mm galv. m/steel angle

brackets all round, fixed to

70x50mm holsec uprights

6,4mm Safety glass signage panel

side fixing only to vertical supports

70x50mm holsec top rail.

70x50mm holsec bottom rail.

70x50mm holsec top rail.

70x50mm holsec bottom rail.

SIGNAGE BOARD FRONT ELEVATION

SCALE 1:50

SECTION A-A

SCALE 1:50

1000

1350

50

SIGNAGE PLATE

SCALE 1:50

1000

70x50mm galv m/steel holsec

uprights concreted in

Vertical galv. mild steel signage plate

70mm wide on bothsides,

fixed to posts

'DIAGONAL STREET' letters to be

cut out

70

black enamel paint finish

25x25x4mm galv. m/steel angle brackets all round,

fixed to 70x50mm holsec uprights

6,4mm Safety glass signage panel

side fixing only to vertical supports

SIGNAGE BOARD PLAN

SCALE 1:50

FIXING DETAIL PLAN

SCALE 1:25

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

Signage Board

Detail

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

BHBRP 2211 C 508

2019.06.19 As shown

Heritage Landscape and Public

Environment Upgrade

DESIGNED BYA. L

CHECKED BYA. L

FOR INFORMATION

B JN Tender Issue19 June 2019

AutoCAD SHX Text
A
AutoCAD SHX Text
A
Page 12: FOR INFORMATIONf +27 21 426 1324 e office@ctn.gapp.nett General Notes: 1) All pedestrian ramps to be installed parallel to property boundaries. 2) Levels from sidewalks across driveways

PLAN

SCALE 1:100

CB

Corobrik Burgundy clay paving brick, size:220 x

110mm x 50mm. Colour type: RED.

CC

Corobrik Cederberg clay paving brick, size:220 x

110mm x 50mm. Colour type: YELLOW.

(Herringbone pattern)

CCC

Standard Concrete / Clay Cobble 110 x110 x 50 mm

at 6.05 metres spacing

Colour type: Charcoal / Onyx

WALKWAY TYPE 1 - PAVERS

SPECIFICATIONS

CC

C

CB

CC

CC

C

220

22

00

220

550

2800

550

existing stone retaining

wall to be made good

and removed all existing

foreign plants

existing stone pillars to

be made good and

removed all existing

foreign plants.

525

New brick steps

to architect's detail

Top of Pavers

1746.500

= + 3.000m

(20x150

risers)

Stone clad retaining wall

to architect's detail

Top of Landing

1748.000

Top of Pavers

1749.658

Clay pavers on bedding sand

and paving layerworks to engineer's

specs and details

Pavers to fall @ 2%

90

SECTION

SCALE 1:50

existing stone pillars to be made

good and removed all existing

foreign plants.

50 x 50 x 400mm (long) dry pack wall

Type of Stone: Slate Rich Autumn

PROPOSED

Top of Landing

1756.821

PROPOSED

Top of Landing

1748.000

Potential position of

heritage blue plaque

to architect's detail

330mm treads

Corobrik Cederburg clay pavers

(220 x 110 x 50)

Hardcore compact filling

to engineer's details and

specifications

Concrete footing to

engineer's details and

specifications

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

150

330

330

330

330

330

330

330

330

330

1320

150

330

330

330

330

330

330

330

330

330

330

3300 1300 3300

Risers at 150mm

Corobrik Cederburg clay

pavers

1200

Dimensions to be

confirmed on site prior to

construction of steps

G A P Parchitects/urban designers

johannesburg97 second avenue

melville 2092t +27 11 482 1648f +27 11 482 1216

e [email protected]

CLIENTARCHITECT

No. DATE By DESCRIPTION

Johannesburg Development

Agency

cape town150 longmarket street

cape town 8001t +27 21 424 2390f +27 21 426 1324

e [email protected]

General Notes:

1) All pedestrian ramps to be installed parallel to property boundaries.

2) Levels from sidewalks across driveways to be flush for disabled access.

3) All road markings to be repainted.

4) All existing traffic signs and light poles to be repaired, painted or replaced

where necessary.

5) Final Positions of kerb inlets and pedestrian

ramps to be verified on site.

If the contractor discovers conflicts between

the architectural drawings and the engineers'

drawings, he is to contact the architect

Heritage Gateway

Stairs Detail

PROJECT DRAWING TITLE

DATE

JOB NO

AUTHOR

DRAWING NO.

SCALE

REVISION NUMBER.JN

BHBRP 2211 C 509

2019.06.19 As shown

Heritage Landscape and Public

Environment Upgrade

DESIGNED BYA. L

CHECKED BYA. L

FOR INFORMATION

B JN Tender Issue19 June 2019