flyer cleanpid easy purification kit

2
Reduce the cost of…. Unconclusive results Inhibition of detection Complex matrices Microbiota Cleanpid® Provides you the purified sample that you need for better Legionella detection Legionellae DNA extraction is particularly problematic when different types of microorganisms may be present. Clean your sample and then work with Legionella alone. Cleanpid® Easy Purification kit is the simple method for the separation and purification of Legionella in water samples Biótica Bioquímica Analítica S.L. Scientific and Technological Park of University Jaume I Campus Riu Sec- Building Espaitec 2 Ground floor, laboratory 2 12071 - Castellón de la Plana (Spain) Phone: +34 964 108 131 Fax: +34 964 737 790 [email protected] www.biotica.es

Upload: biotica-bioquimica-analitica-sl

Post on 08-Aug-2015

58 views

Category:

Marketing


4 download

TRANSCRIPT

Reduce the cost of….Unconclusive resultsInhibition of detectionComplex matricesMicrobiota

Cleanpid® Provides you the purified sample that you need for better Legionella detection

Legionellae DNA extraction is particularly problematic when different types of microorganisms may be present. Clean your sample and then work with Legionella alone.

Cleanpid® Easy Purification kit is the simple method for the separation and purification of Legionella in water samples

Biótica Bioquímica Analítica S.L.Scientific and Technological Park of

University Jaume ICampus Riu Sec- Building Espaitec 2

Ground floor, laboratory 212071 - Castellón de la Plana (Spain)

Phone: +34 964 108 131 Fax: +34 964 737 790 [email protected]

bCleanpid® improves the sensitivity and reproducibility of qPCR.

Ct. number of amplification cycles

Number of test

Kit content

Funcionality

Processing time

Hands - on time

Highly robust performance

Specificinstrumentation

Storage

Reagents for 50 test (Ref. 611-10-00)

Capturing reagent, Working buffer

The purified organism is suitable for DNA extraction by simply freeze/thaw cycles (symply and cost-efficient lysis)

60 minutes for any number of samples, approximately

Quick and Easy-To-Use

Produces consistent and reproducible results

The kit only requires a magnetic rack

2 - 8ºC

technical features

Schrader C, Schielke A, Ellerbroek L and Johne R: PCR inhibitors – occurrence, properties and removal. 2012, Journal of Applied Microbiolo-gy, 113, 1014—1026.doi:10.1111/j.1365-2672.2012.05384.x

BEFORE AFTER

“Immunocapture methods are very efficient in removal of PCR inhibitors because the pathogen can be specifically separated from the sample matrix and the accordant inhibitors”

Add Legionella binding magnetic beads to the sample contained in the capture tube and mix by repeated pipetting. Incubate for 60 min with gently shaking.

Place the tube on the magnetic rack to separate magnetic beads and discard supernatant.

Resuspend the bead pellet in the working buffer by repeated gently pipetting. Retain again and discard supernatant (3X).

Legionella binding magnetic beads for capturing cells(immunomagnetic separation)

method

tube complexes magnetic beads-

Legionella

magnet

Resuspended magnetic beads

Freeze/Thaw cycles

Magnetic retention

Magnetic beads Supernatant (DNA)

Ready to PCR assay!

The PCR is prone to inhibitory substances which may be present in the environmental sample and which may affect the sensitivity of the assay or even lead to false negative results.

Moreover, to detect Legionella, the sample is usually concentrated to very small volumes and this often results in concurrent concentration of the different inhibitors and increased interference with PCR. The dilution of the sample or the extracted DNA result in a dilution of the inhibitors but also result in a decrease of the sensitivity.

The discarding of PCR inhibitors in one step by Cleanpid allows obtaining a larger amount of DNA from the water samples and avoiding dilution, therefore helping to reduce false negative rate.

Reduction of false positive rate for PCR

Reduction of false negative rate for PCR

The false positive is due to PCR quantifies total DNA of Legionella in a sample, which proceed not only from living cells but also from damaged or dead cells, and free DNA (exogenous).

The false positive could also be due to cross-reactivity in the PCR assay with other accompanying microorganisms in the sample

The selective separation of intact cells by Cleanpid allows detecting only the DNA of potentially viable cells of Legionella, providing a reduction of false positive rate.

enefits

40

35

30

25

20

15