fluke bp120mh nimh battery pack for fluke 120 series ... (p… · pm8907 power adapter/charger. the...

95
Fluke BP120MH NiMH Battery Pack for Fluke 120 series, Fluke 43 and 43B Overview: Battery pack as replacement battery in the Fluke 120 series ScopeMeters and in the Fluke 43 and 43B Power Quality Analyzers. The BP120MH is a Nickel-Metal-Hydride Battery Pack, made specifically to support the ScopeMeters and Power Quality Analyzers mentioned. Features: The battery capacity is 3000 mAh, this is 50% more than that of the original BP120. As a result, the instrument-user will benefit from a much longer 'up time' than with the original NiCd battery, at the same volume and weight. The BP120MH is more environmental-friendly than the NiCd battery used before, as it contains no heavy metals. Just as before, the battery pack can be charged while installed in the instrument, using the PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage 4.8 V Capacity 3000 mAh Model Name Description Fluke BP120MH Fluke BP120MH NiMH Battery Pack for Fluke 120 series, Fluke 43 and 43B

Upload: others

Post on 28-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke BP120MH NiMH Battery Pack for Fluke 120 series, Fluke 43 and 43B

Overview:

Battery pack as replacement battery in the Fluke 120 series ScopeMeters and in the Fluke 43 and 43B Power Quality Analyzers. The BP120MH is a Nickel-Metal-Hydride Battery Pack, made specifically to support the ScopeMeters and Power Quality Analyzers mentioned.

Features: The battery capacity is 3000 mAh, this is 50% more than that of the original BP120. As a result, the instrument-user will benefit from a much longer 'up time' than with the original NiCd battery, at the same volume and weight. The BP120MH is more environmental-friendly than the NiCd battery used before, as it contains no heavy metals. Just as before, the battery pack can be charged while installed in the instrument, using the PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike.

Specs:

Nominal voltage 4.8 V

Capacity 3000 mAh

Model Name Description

Fluke BP120MH Fluke BP120MH NiMH Battery Pack for Fluke 120 series, Fluke 43 and 43B

Page 2: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 3: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

For more information and detailed specifications, go to www.fluke.com/accessories

Accessories

Fluke specialty accessories and software

Extend the utility of your multimeter

Fiber optics

PV350 Pressure Vacuum Module• Digitalpressureandvacuummeasure-

mentsinasinglemodule• MeasureshVac/r,hydraulicand

pneumaticpressuresto350psig/2413kpa(usableto500psig)

• Measuresto76cmhg(29.9inhg)vacuum(notintendedformeasuringmicronsofvacuum)

• compatiblewithmostpopulardigitalmultimeters

FOM Fiber Optic MetertheFlukeFiberOpticMeter(FOM)helpsyoutestandmaintainfiberopticcablewithouthavingtobuyawholenewmeter.plugtheFOMdirectlyintoanyDMMwithamVdcfuntionanda10mWinputimpedance,andquicklyandaccuratelyverifyfiberopticcablesystemloss.lightsourcesandpatchcordssoldseparately.

Logging software

FlukeView® FormsharnessthepowerofthedataloggingfunctiononyourFlukeDigitalMultimeter,thermometerorprocessMeter.loglivereadingswhileconnectedtoapc,orleaveyourFluke189,789or54-IIinplacetocaptureupto1,000readingsfordownloadtoapc.FlukeView®Formseasy-to-usewizardsallowyoutodownloadread-ingsfromyourFluketoolandstoreanddisplayindividualreadingsoraseriesofmeasurements.spottrendsanddocu-mentinterruptionsorspikes.UsestandardformsortheFlukeView®Designerfeaturetocustomizereportsusingyourspecificdataorcompanylogo.Freedemo-readerdownloadallowsco-workersorclientstoopenyourreportandinteractwithcap-tureddata.Choose the model that’s right for you:• FVF-sc1:Includessoftwareandcable

usedwith53-IIand54-IIthermometersand87IVand89IVDMMs

• FVF-sc2:Includessoftwareandcableusedwith180seriesDMMsand789processMeters

• FVF-sc3:Includessoftwareandcableusedwith45BenchMeters

Gotowww.fluke.com/flukeviewformstodownloadthedemo.

FlukeView® Forms BasicanabridgedversionofFlukeViewForms.analyzeandsharedatawiththeprovidedstandardforms.availableforusewith180seriesDMMsand789processMeters,only.UpgradetothefullFlukeViewFormswithFVF-UG.

Make extended logging easier

BP189 High Capacity Battery Pack for Fluke 180 Series Multimeters• Expandsbatterylifeupto450hours• acceptsfourcbatteries• allowsyoutouseyourFluke189to

continuallylogdataforuptotwoweeks

FOS 850 and FOS 850/1300 Fiber Optic Light SourcesavarietyoflEDlightsourcesallowyoutotestdifferentcables.

H900 Test Lead Holder• heavydutyconstructionwith

mountingholes• holderhas10slotsforwiresupto

8mmindiameter• Over-alldimensions:27.9cmlx

8.9cmWx3.2cmh• One-yearwarranty

Pressure and vacuum

SV225/10PAK• packof10strayvoltageadapters• adaptermakessuremeterhaslowinput

impedencethateliminatesstrayvoltage

Stray voltage

65

Page 4: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Home Applications Products Where To Buy What's New Support About Us

Product Search

Product Home

Manuals

Accessories > Batteries, Chargers & Adapters >

BP7217 Ni-Cd Battery PackDescription: 7.2V 1700 mA-hour rechargeable Ni-Cd battery pack. Application: Provides typical 8-hour battery life when used in 700 or 740 Calibrator. Included: One battery pack. Material: Six 1.2V dc Ni-Cd cells in custom-molded ABS/PC-blend case. Dimensions: 7.1" x 2.2" x .9" (150 mm x 56 mm x 22 mm) Weight: 11 oz/310g Warranty: One year

Model Name Description

BP7217 Ni-Cd Battery Pack

* Manufacturers suggested U.S. list price. Applies to U.S. purchases only.Contact your local Fluke representative for specific details, options, and prices.

BP7217 Ni-Cd Battery Pack

http://us.fluke.com/usen/products/AccessoryDetail.htm?cs_id=17920%28FlukeProducts%29&catalog_name=FlukeUnitedStates11/19/2005 3:59:56 PM

Page 5: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke BP7235 NiMH Battery Pack

Overview:

7.2 V 3500 mA-hour rechargeable Ni-MH battery pack. Provides typical 16-hour battery life when used in 700 or 740 Calibrator.

Features: Includes one battery pack.

Specs:

Material Six 1.2 V DC Ni-MH cells in custom-molded ABS/PC-blend case Application 7.1 x 2.2 x .9 in (150 x 56 x 22 mm) Dimensions 7.1 x 2.2 x .9 in (150 x 56 x 22 mm) Weight 11 oz / 310g Warranty One year This item replaces BP7217 Ni-Cd Battery Pack.

Model Name Description

Fluke BP7235 Fluke BP7235 NiMH Battery Pack

NiMH Battery Pack

Page 6: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 7: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Cases and Holsters

C75 Accessory Case Zippered carrying case

with 2 inside pockets

C90 Meter Case Zippered carrying case

with inside pocket andbelt loop

C125/C781 MeterCase Zippered carrying case

with detachable externalpouch

C195 Case Zippered carrying case

with storagecompartments

Allows hand orshoulder use

C789 Meter &Accessory Case Large fabric carrying

case with 3compartments,removable handle andshoulder strap

C550 Tool Bag Steel reinforced frame Rugged ballistic cloth with heavy duty

hardware Large zippered storage

compartment with25 pockets

Weather resistant Carry all your tools

to the job

C12A Meter Case Zippered carrying case

with inside pockets andbelt loop

C25 Meter Case Zippered carrying case

with padding and insidepocket

C50 Meter Case Zippered carrying case

with inside pocket beltloop and inside meterstrap

Soft Cases

Cases & Holsters Compatibility Chart

Soft Cases Size (HxWxD) C12A 172 x 128 x 38C25 218 x 128 x 64C50 192 x 90 x 38C75 179 x 103 x 26 For multiple test leads and accessoriesC90 205 x 90 x 72C125 192 x 141 x 58C195 231 x 513 x 231C781 269 x 141 x 90C789 308 x 256 x 77C550 333 x 513 x 231 For multiple meters, accessories or other toolsHard CasesC20 256 x 154 x 106C100 397 x 346 x 122C120 346 x 397 x 128C190 410 x 474 x 135C800 230 x 385 x 115Leather CasesC510 287 x 179 x 106C520A 256 x 154 x 106C530 205 x 333 x 26 For several accessories, with or without metersHolstersC10 154 x 77 x 45C70Y, C70G 186 x 90 x 45C81Y, C80G 204 x 102 x 51H110 154 x 96 x 45OtherH3 231 x 90 x 64H5 192 x 90 x 38SH100

110/

111/

112

175/

177/

179

183/

185

187/

189

83/8

5/87

III

73 I

II

77 I

II

12 16 867B

27 45 7-6

00

T3/T

5

321/

322

333/

334/

335/

336/

337

1520

41B

43B

123

190

Seri

es

705/

707

712

714

715

717

718

724

725

741B

/743

B/7

44

787

789

50S/

50D

51/5

2/53

/54

II

All accessories have a one year warranty

Page 8: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Cases and Holsters

10016-ENG Rev. 04

C10 Meter Holster Snap-on yellow holster

absorbs shocks and protectsmeter from rough handling

Includes built-in stand andhanger loop

C70Y, C70G, C81Y,C81G Meter Holsters Snap-on holster absorbs

shocks and protects meterfrom rough handling.

Y for yellow colour, G forGray colour

Flex Stand™ allows meterto hand, lean or stand forconvenience and best viewing

Built-in probe and lead storage

H110 Meter Holster Snap-on yellow holster absorbs

shocks and protects meter fromrough handling.

Built-in probe and leadstorage

Accepts ToolPak accessoryfor convenient hanging

H3 Clamp Meter Holster Fabric holster absorbs shocks and

protects meter from rough handling. Built-in pocket for lead storage Convenient belt-loop with snap

H5 Electrical Tester Holster Rugged fabric holster includes

flap for lead storage andbuilt-in belt loop

Fits Fluke T3 and T5 testers

SH100 Shoulder Strap Shoulder strap for Fluke 1520

C20 Meter Case Heavy duty case with

carrying handle andaccessories storagecompartment

Top cover snaps onto back to serve as tilt stand

C100 Meter andAccessory Case Tough polyprophylene case

C120 and C190 Cases Heavy duty cases with

accessory storagecompartments

C800 Meter andAccessory Case Tough polyprophylene case Accessories and manual

compartments Detachable lid

Hard Cases Holsters

Leather Cases

C520A Leather Tester Case Oiled genuine top grain cowhide Oil tanned for long life Rugged construction with

heavy duty stitching andreinforced rivets

Large tool belt loopand top flap to securetester

Holds Fluke Electrical Testers

C530 Leather Accessory Case Genuine top grain cowhide Heavy duty zipper with convenient pull Ideal for storing Fluke leads,

probes and otheraccessories

Large enough to hold ameter plus accessories

C510 Leather Meter Case Oiled genuine top grain cowhide Rugged construction with heavy duty

stitching and reinforcedrivets

Large tool belt loop andtop flap to securemeter

Holds most Fluke DMMs,Thermometers, and ProcessCalibrators

Page 9: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke C12A Meter Case

Features:

Zippered carrying case with inside pockets and belt loop 1 year warranty

Model Name Description

Fluke C12A Fluke C12A Meter Case

Page 10: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke C25 Large Soft Case for DMMs

Overview:

Give your Fluke tools the protection they deserve. You bought the best, why not protect them with Fluke cases. The C25 carrying case is a durable, zippered carrying case with padding and inside pocket, and high quality polyester exterior. It includes a convenient hand strap and carries most of Fluke’s popular digital multimeters. Our most popular case sold to date! Now available in standard and camouflage designs.

Features:

Zippered carrying case with padding and inside pocket. One year warranty

Specs:

Dimensions (H x W x D) 218 x 128 x 64 mm 8.6 x 5 x 2.52 in

Model Name Description

Fluke C25 Fluke C25 Large Soft Case for DMMs

Page 11: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

For more information, go to www.fluke.com/accessoriesAccessories5656

C35 soft Carrying Case• Made of durable polyester 600D• Dimensions (HxWxD): 220 x 140 x

65 mm (8.7 x 5.5 x 2.6 in)C23 soft Carrying Case• Made of vinyl• Dimensions (HxWxD): 225 x 95 x 58 mm

(8.9 x 3.75 x 2.3 in)C280 soft Case• Made of durable polyester 600D• Dimensions (HxWxD): 230 x 185 x

65 mm (9 x 7.3 x 2.6 in)C115 soft Carrying Case• Made of durable polyester 600D• Dimensions (HxWxD): 240 x 205 x

75 mm (9.5 x 8 x 3 in)C116 soft Carrying Case• Made of durable polyester 600D• Dimensions (HxWxD): 240 x 230 x

65 mm (9.5 x 9 x 2.6 in)C781 Meter Case• Made of durable polyester 600D• Dimensions (HxWxD): 269 x 141 x 90 mm

(10.6 x 5.6 x 3.5 in)C33 soft Carrying Case• Made of vinyl• Dimensions (HxWxD): 280 x 115 x 55 mm

(11 x 4.5 x 2.2 in)C789 Meter and accessory Case• Made of durable polyester 600D• Dimensions (HxWxD): 308 x 256 x

77 mm (12 x 10 x 3 in)

soft casesCaMo-C25 Camouflage Carrying Case• High quality 1000D fabric• Dimensions (HxWxD): 20.3 x 12.1 x

4.6 cm (8 x 4.8 x 1.8 in)CaMo-C37 Camouflage Carrying Case• High quality 1000D fabric• Dimensions (HxWxD): 26.5 x 9 x 3 cm

(10.5 x 3.5 x 1.2 in)C12a Meter Case• Made of vinyl• Dimensions (HxWxD): 172 x 128 x 38 mm

(6.8 x 5 x 1.5 in)C75 accessory Case• Made of vinyl• Dimensions (HxWxD): 179 x 103 x 26 mm

(7 x 4 x 1 in)C50 Meter Case• Made of vinyl• Dimensions (HxWxD): 192 x 90 x 38 mm

(7.56 x 3.5 x 1.5 in)C25 large soft Case for DMMs• Made of vinyl• Dimensions (HxWxD): 218 x 128 x 64 mm

(8.6 x 5 x 2.52 in)C90 soft Case for DMMs• Made of vinyl• Dimensions (HxWxD): 205 x 90 x 72 mm

(8 x 3.5 x 2.8 in)

Fluke cases and holstersA premium meter deserves a premium case

C550 CXT80 H5 C520aC35 CaMo-C25

Cases and Holsters Selection Guide 11

3/11

4/11

5/11

6/11

7

27 I

I/28

II

77-4

/175

/177

/179

83V/

87V

233

287/

289

8845

A/8

846A

/880

8A

120/

190/

22X

Seri

es

51-I

I/52

-II/

53-I

I B/5

4-I

I B

561/

566/

568

63/6

6/68

321/

322

355

365/

373/

902

374/

375/

376/

381

705/

707

712/

714/

715/

717/

72X

Seri

es

718/

719

753/

754

787/

789

T+/T

+PR

O

T5-6

00/T

5-10

00

1503

/150

7/15

77

C12A • •

C23 • • • • •

Camo-C25 • • • • • • • • • • • •

C25 • • • • • • • • • • • •

C33 • • • •

C35 • • • •

Camo-C37 • 365 • • •

C43 • • • • • • • • •

C50 • •

C75 The C75 is designed to hold test leads, probes, clips and other required accessoriesC90 • • • •

C100 • • • • • 71X 787C101 • • • • • • • • • • • • • • • • • •

C115/C116 • • • • • • • 365 • • • •

C125 • • 83V •

C280 • • • • • • • • • • • • •

C345 The perfect case for carrying a wide range of Fluke handheld test tools and accessoriesC510 • • • • 787C520A • •

C550/C1600 The C550 and C1600 are large enough to hold accessories and multiple test toolsC781 • • • • 72X • • 789 •

C789 • • • 365 • •

C799 •

C800 • • • • • • 71X 787CXT80 • • • 72X •

CXT170 • • • 71X • •

CXT280 • •

C43 soft Carrying Case• Made of durable polyester 600D• Dimensions (HxWxD): 318 x 230 x

90 mm (12.5 x 9.1 x 3.5 in)C550 Tool Bag• Made of ballistic cloth with heavy-duty

hardware• Dimensions (HxWxD): 333 x 513 x

231 mm (13 x 20.2 x 9.1 in)C345 soft Case• Made of durable polyester 600D• Dimensions (HxWxD): 360 x 200 x

240 mm (14 x 8 x 9.5 in)

Hard casesCXT series extreme Cases• Models CXT80, CXT170, and CXT280 for

various meter compatibility• Unbreakable, watertight, airtight, chemi-

cal resistant and corrosion proofC800 Meter and accessory Case• Dimensions (HxWxD): 230 x 385 x

115 mm (9 x 15 x 4.5 in)C101 Hard Case• Exterior dimensions (HxWxD): 305 x

360 x 105 mm (12 x 14.2 x 4.1 in) • Interior dimensions (HxWxD): 230 x

290 x 65 mm (9 x 11.5 x 2.5 in)C100 universal Carrying Case• Dimensions (HxWxD): 397 x 346 x

122 mm (15.7 x 13.6 x 4.8 in)C1600 gear Box• Includes five hook and loop straps to

wrap cords and test leads• Dimensions (HxWxD): 260 x 390 x

200 mm (10 x 15 x 7.8 in)

leather casesC520a leather Tester Case• Dimensions (HxWxD): 256 x 154 x

106 mm (10 x 6 x 4 in)C510 leather Meter Case• Dimensions (HxWxD): 287 x 179 x

106 mm (11 x 7 x 4 in)

HolstersH80M Protective Holster• Includes a hanging magnet, general pur-

pose hanger, and hook and loop straps • Dimensions (HxWxD): 190 x 95 x 43 mm

(7.5 x 3.7 x 1.7 in)H5 electrical Tester Holster• Dimensions (HxWxD): 192 x 90 x 38 mm

(7.5 x 3.5 x 1.5 in)H3 Clamp Meter Holster• Dimensions (HxWxD): 231 x 90 x 64 mm

(9 x 3.5 x 2.5 in)H6 IR Thermometer Holster• Dimensions (HxWxD): 302 x 178 x 57 mm

(11.9 x 7 x 2 in)

Page 12: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke C100 Universal Carrying Case

Overview:

Tough polyprophylene case 1 year warranty

Model Name Description

Fluke C100 Fluke C100 Universal Carrying Case

Page 13: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke C125 Meter Case

Features:

Zippered carrying case with detachable external pouch Accomodates Fluke 120 Series ScopeMeter Testtool or a handheld DMM, both main instrument

and test accessories Front pouch can be detached for optimal flexibility 1 year warranty

Model Name Description

Fluke C125 Fluke C125 Meter Case

Page 14: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

®

EI-162BN Split-Core Transformer

Users Manual

PN 2842250 June 2007 © 2007 Fluke Corporation, All rights reserved. Printed in the Netherlands. All product names are trademarks of their respective companies.

Page 15: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption.

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke re-serves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country.

Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a de-scription of the difficulty, postage and insurance prepaid (FOB Destination). Fluke as-sumes no risk for damage in transit. Following warranty repair, the product will be re-turned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the prod-uct’s specified rating, or normal wear and tear of mechanical components, Fluke will pro-vide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PAR-TICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and ex-clusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.

Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands

11/99

To register your product online, visit register.fluke.com

Page 16: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

i

Table of Contents

Title Page

Introduction .......................................................................................... 1 Unpacking............................................................................................. 1 Packing ................................................................................................. 1 Safety Regulations ................................................................................ 2 Symbols ................................................................................................ 3 Accessories ........................................................................................... 4 Features................................................................................................. 5 Using the Split-Core Transformer......................................................... 6

Installing Transformer around Pylon Footing ................................... 6 Determining Transformation Ratio Connections .............................. 8 Connecting Transformer to Earth Ground Tester.............................. 10

Maintenance.......................................................................................... 12 Cleaning............................................................................................ 12 Corrosion Prevention ........................................................................ 12

Specifications........................................................................................ 13 General.............................................................................................. 13 Technical Data for Selective Earth Resistance Measurements.......... 13

Service .................................................................................................. 14 Storage.................................................................................................. 14

Page 17: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

ii

Page 18: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

iii

List of Tables

Table Title Page

1. Features and Functions ......................................................................... 5 2. Transformation Ratios .......................................................................... 8

Page 19: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

iv

Page 20: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

v

List of Figures

Figure Title Page

1. Features................................................................................................. 5 2. Installing Transformer Around Pylon ................................................... 7 3. Transformation Ratio Connections ....................................................... 9 4. Test Measurement Setup....................................................................... 11

Page 21: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

vi

Page 22: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

1

EI-162BN Split-Core Transformer

Introduction The Fluke EI-162BN Split-Core Transformer (hereafter referred to as the “Transformer”) is used with an earth ground tester (hereafter referred to as the “Tester”) to make selective earth ground resistance measurements (RE) on transmission line pylons. The Transformer is designed to work with Fluke 1625 and 1623 GEO Earth Ground Testers.

This instrument is manufactured in compliance with quality assurance system DIN ISO 9001. Compliance with current applicable EMC regulations is documented by the attached P sign.

Unpacking Refer to “Accessories” while unpacking the Transformer and its accessories from the shipping carton. Keep the packing material for later transport.

Check for missing parts and inspect the unit carefully for damage, like cracks, dents or bent parts. If items are missing or any physical damage is apparent, call Fluke for assistance. Refer to “Service” for information on contacting Fluke.

Packing Use only the original packing material to ship the Transformer.

Page 23: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

2

Safety Regulations This device is only to be installed and operated by qualified personnel in compliance with the safety precautions and regulations that follow. Additionally, use of this device requires compliance with all legal and safety regulations pertaining to each specific application. Similar regulations apply to the use of accessories.

Qualified personnel are persons familiar with the setup, installation and operation of the device, are formally qualified to perform activities like training and instruction, and are authorized to switch on and off, isolate, ground, and label electric circuits and instruments/systems in accordance with safety engineering standards.

In this manual, a WWarning identifies hazardous conditions and actions that could cause bodily harm or death. A WCaution identifies conditions and actions that could damage the instrument or the equipment under test, cause permanent loss of data, or impair instrument performance. Disregarding warning and caution notices can lead to serious physical injury and material damage.

Fault-free and safe operation of this device requires suitable transport, storage, setting up, and assembly, as well as careful operation and maintenance.

If there is reason to believe that safe operation is no longer possible, the device must be put out of operation immediately and must be protected against accidental usage.

XW Warning

Operating electrical devices implies that parts of the device could carry dangerous voltages. To avoid electrical shock or damage to the device:

• If this product is used in a manner not specified by the product specifications, the protection provided may be impaired.

• While a measurement is in progress, do not touch the Transformer, transmission line pylon, earth ground electrode, auxiliary electrode, or probe.

Page 24: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Split-Core Transformer Symbols

3

• Assume that safe operation of the device is not possible if it shows visible damage.

• Assume that safe operation of the device is not possible if it has been exposed to unfavorable conditions (for example, storage beyond the permissible climatic limits without adaption to the ambient climate and dewing).

• Assume that safe operation of the device is not possible if it has been exposed to major strain during transport (for example, dropped from some height without visible external damage).

Symbols The following symbols are found on the Transformer or in this manual.

X Hazardous voltage. Voltage >30 V dc or ac peak might be present.

W Risk of danger. Important information. See Users Manual.

⊥ Common

P Conforms to relevant European Union directives

J Earth ground

Page 25: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

4

Accessories The following accessories are shipped with your Transformer:

• Two fasteners for holding Transformer halves together

• One cable bobbin with two 12-meter (40-foot) test leads for connecting the Transformer to the Tester’s jack. The female red and blue leads then plug onto the male red and blue banana plugs on the sensing cable adapter used with the Fluke 1623 and 1625 for selective resistance measurements. (Sensing cable adapter, Fluke part number 2539195).

• One contact clamp for establishing an earth ground electrode connection point on the transmission line pylon. The clamp features a fastener that secures the clamp to the pylon’s frame. The clamp also has a 4-mm bore hole that fits a standard banana plug, with a tightening screw for securing the plug.

• One carrying case

• Users manual

Page 26: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Split-Core Transformer Features

5

Features See Figure 1 and Table 1 for Transformer features and functions.

!200

5001000

NORMA

A 6805 06211

1

3

2

evx01.eps

Figure 1. Features

Table 1. Features and Functions

Item Description

A Transformer half (2)

Transformer end faces have bolts that pivot to aid in separating the Transformer halves One Transformer end face has a slotted bolt hole that allows the bolt to pivot out of the end face

B Transformation ratio connections: ⊥, 200, 500, and 1000

C Fastener (2)

Page 27: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

6

Using the Split-Core Transformer

Installing Transformer around Pylon Footing

To install the Transformer around a pylon footing:

1. Loosen (or if required, remove) the fasteners. See Figure 2. If extra leverage is needed to loosen a fastener, insert a lever (like a small screwdriver) into the 4 mm bore hole in the fastener.

2. On the end face with the slotted bolt hole, pivot the fastener/bolt out of the way, and then separate the two halves of the Transformer. See Figure 2.

3. Install the Transformer around the pylon footing. See Figure 2.

W Caution

• Damage to the Transformer end faces can greatly impair performance. Use care when joining the end faces together.

• Foreign substances on the end faces can distort measurement results. Before fastening together, ensure the end faces are clean. If required, see “Cleaning.”

• Airgaps between the end faces can distort measurement results. When fastening the end faces together, ensure the fasteners are tightened firmly.

4. Join the two halves of the Transformer so the end faces meet. On the end face with the slotted bolt hole, pivot the fastener/bolt into place. If fasteners were removed, install the fasteners. Tighten fasteners firmly. See Figure 2. If extra leverage is needed to tighten a fastener, insert a lever (like a small screwdriver) into the 4 mm bore hole in the fastener.

Page 28: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Split-Core Transformer Using the Split-Core Transformer

7

evx02.eps

Figure 2. Installing Transformer Around Pylon

Page 29: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

8

Determining Transformation Ratio Connections

Before you connect the Transformer to the Tester, you need to determine a suitable transformation ratio for the minimum measuring and maximum parasitic currents expected to flow through the transmission line pylon.

The Transformer has 1000 windings, with connections at winding ratios of 1000, 500, 200 and 0 (⊥). Depending on the combination of connections used, the Transformer can provide transformation ratios of 1:1000, 1:800, 1:500, 1:300, and 1:200.

See Table 2 to determine a suitable transformation ratio for the expected minimum measuring and maximum parasitic currents, and then see Figure 3 for the Transformer connections that will provide that ratio. These connections will be used for connecting the Transformer to the Tester’s Ajack.

Note

Be sure to adjust your earth ground tester to the selected transformation ratio.

Table 2. Transformation Ratios

Ratio Current

1:1000 [1] 1:800 1:500 1:300 1:200

Min. Measuring Current [2]

0.50 mA 0.40 mA 0.25 mA 0.15 mA 0.10 mA

Max. Parasitic Current [3]

3.0 A 2.4 A 1.5 A 0.9 A 0.6 A

[1] For nearly all selective earth ground resistance measurements, a ratio of 1:1000 is recommended

[2] At 94, 105, 111, and 128 Hz

[3] At 50, 60 and 16-2/3 Hz

Page 30: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Split-Core Transformer Using the Split-Core Transformer

9

200

500

1000

200

5001000

200

5001000

200

5001000

200

5001000

200

5001000

1 : 200

1 : 300

1 : 500

1 : 800

1 : 1000

evx03.eps

Figure 3. Transformation Ratio Connections

Page 31: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

10

Connecting Transformer to Earth Ground Tester

W Caution

Corrosion and paint on a pylon can impede the connection between the contact clamp and the pylon’s frame. When installing the contact clamp, ensure the tip of the clamp fastener penetrates all layers of paint and corrosion.

1. Install the contact clamp to the pylon and tighten the clamp fastener. The contact clamp can now be used as the connection point for the Tester’s earth ground electrode test lead. See Figure 4.

2. Install a test lead from the Tester’s earth ground electrode jack to the contact clamp. Plug the test lead into the bore hole in the clamp and tighten the tightening screw. See Figure 4. For Fluke 1625 / 1623 GEO Earth/Ground Testers, the earth ground electrode jack is labeled C1 or E.

3. Install the 12-m (40-ft) test leads from the Tester’s Ajack to the Transformer’s transformation ratio connections. To determine which transformation ratio connections to use, see “Determining Transformation Ratio Connections.”

4. In accordance with the Tester’s users manual, install test leads from Tester to the probe and auxiliary earth electrode, and then perform your earth ground resistance measurement (RE).

Page 32: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Split-Core Transformer Using the Split-Core Transformer

11

ParasiticCurrent

MeasuringCurrent

Red

Probe Aux. Earth Electrode

sulp

V 05 xam

FLUKE

FLUKE 1623 Earth/Ground Tester

evx04.eps

Figure 4. Test Measurement Setup

Page 33: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

12

Maintenance Only trained and qualified staff should perform maintenance on this instrument.

In all repair and reconditioning work, ensure the Transformer’s design parameters are not modified to the detriment of safety, that only authorized parts are used, and that parts are reassembled to their factory-issued configuration.

Cleaning

W Caution

To prevent damage to the Transformer when cleaning:

• Do not use strong cleaning detergents or solvents (like trichloroethylene).

• Do not allow liquid to get inside the instrument.

• Do not use sharp tools to clean the end faces.

If your Transformer requires cleaning, wipe it with a cloth lightly dampened with a mild rinsing agent.

Corrosion Prevention

To help prevent corrosion to the Transformer end faces, the cleavage planes should be lightly oiled.

Page 34: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Split-Core Transformer Specifications

13

Specifications

Note

Fluke reserves the right to modify specifications without notice for the purpose of product improvement.

General Temperature Range

Working Temperature ......................................... -10 °C to +50 °C (+14 °F to +122 °F) Storage Temperature ......................................... -30 °C to +60 °C (-22 °F to +140 °F)

Dimensions Outer diameter.................................................... 377 mm (15 in) Inner diameter..................................................... 310 mm (12 in) Depth ................................................................. 30 mm (1.25 in)

Weight Split-core transformer ......................................... 4.9 kg (11 lb) Total (with accessories and packaging).............. 7.7 kg (17 lb)

Transformation Ratios ......................................... 1 : 1000 1 : 800 1 : 500 1 : 300 1 : 200

Technical Data for Selective Earth Resistance Measurements Insulation voltage ................................................. 2 kV (core against secondary winding) Max. current through split-core transformer ..... 3 A (primary current, transformation

ratio 1:1000) Additional Error for Selective Earth Resistance Measurements

Primary current >2.5 mA..................................... ±2 % (transformation ratio 1:1000) Primary current <2.5 mA..................................... ±5 % (transformation ratio 1:1000)

Page 35: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

EI-162BN Users Manual

14

Service If your Transformer is operated and handled properly, it should not require servicing. However, if you suspect that the Transformer has failed, review this manual to ensure you are operating it correctly. If it still fails to operate properly, pack securely using the original packing material (if available) and forward, postage paid, to the nearest Fluke Service Center. Include a brief description of the problem. Fluke assumes no responsibility for damage in transit.

To locate an authorized service center, call Fluke using the phone numbers listed below:

USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31-402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500

You may visit us on the World Wide Web at http://www.fluke.com.

To register your product, visit http://register.fluke.com.

Storage When your Transformer is not going to be used, store it in the carrying case provided.

Page 36: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke Food Pro Plus

Fluke Food Pro Plus Food Safety Thermometers

Fluke brings their test and measurement equipment expertise to the foodservice industry through contact and non-contact temperature mea-surement solutions. Foodservice professionals understand the need for complete, accurate and fast temperature monitoring from point of receiv-ing through holding and serving, and the Fluke FoodPro Series provides the temperature measurement tools required to properly screen those temperatures.

All FoodPro thermometers are hand-washable, NSF certified and feature the unique HACCP check lights which immediately indicates safe or risky holding temperatures through green or red lights. Fluke FoodPro Food Safety Thermometer

• Non-contact temperature scans for safe, easy and fast surface temperature readings without risk of cross-contamination

• HACCP check lights for instant recognition of safe/unsafe temperatures

• LED target illumination highlights the entire measurement spot foraccurate targeting

• NSF certified and hand washable (non-submersible)

Fluke FoodPro Plus Food Safety Thermometer includes FoodPro fea-tures and the following:

• Contact temperature measurements with field-replaceable probe forinternal readings

• Countdown timer with audible alarm for line check audit reminders• Backlit display for clear readings in poorly lit areas• MAX temperature displayed for quick reference

Shop for Fluke products online at: 1.877.766.5412www.MyFlukeStore.ca

Page 37: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Infrared Specifications (both)

Temperature Fluke FoodPro -30 ºC to 200 ºCFluke FoodPro Plus -35 ºC to 275 ºC

Accuracy (Assumes ambient operating temperature of 23 ºC ±2 º)Between 0 ºC and 65 ºC: ±1 ºCBelow 0 ºC : ±1 º ±0.1 degree/degreeAbove 65 ºC): ±1.5 % of reading

Response time <500 ms after initial reading

Spectral Response 8-14 microns

Emissivity Pre-set for foodservice applications

Distance to spot size/Optical Resolution (D:S)

2.5:1 @ 90 % energy, typical

Typical working range (target illumination)

≈25 mm to 250 mm

Minimum target size 12 mm ø

Illumination to IR channel offset

13 mm

Probe Specifications (FoodPro Plus)

Temperature FoodPro Plus -40 ºC to 200 ºC

Accuracy (Assumes ambient operating temperature of 23 ºC ±2º)FoodPro Plus Between –5 ºC and 65 ºC : ±0.5 ºC

Below –5 ºC : ±1 ºCAbove 65 ºC: ±1 % of reading

Response time FoodPro Plus 7-8 secons (3 time constants)

Probe dimensions FoodPro Plus Diameter: 3.0 mmLength: 90 mm

Sensor type FoodPro Plus Thin-film platinum, class A, ResistanceThermal device (RTD)

Operational Specifications (both)

Repeatability Within accuracy specifications of the unit

Ambient operating range 0 ºC to 50 ºC

Relative Humidity 90 % (+/- 5 %) RH non condensing @ 30 ºC

Storage Temperature -20 ºC to 60 ºC

Weight FoodPro 100 g (with battery)FoodPro Plus 150 g (with battery)

Dimensions FoodPro 150 mm x 30 mm x50 mmFoodPro Plus 165 mm x 32 mm x 50 mm

Power, battery life FoodPro 1 AA alkalineFoodPro Plus 9 V alkaline

Battery Life alkaline 10 hours minimum @ 23 ºC

Target illumination High Brightness LED

FoodPro and FoodPro Plus Food Safety Thermometers

Shop for Fluke products online at: 1.877.766.5412www.MyFlukeStore.ca

Page 38: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

FoodPro and FoodPro Plus Food Safety ThermometersInfrared Specifications (both)

Temperature Fluke FoodPro -30 ºC to 200 ºCFluke FoodPro Plus -35 ºC to 275 ºC

Accuracy (Assumes ambient operating temperature of 23 ºC ±2 º)Between 0 ºC and 65 ºC: ±1 ºCBelow 0 ºC : ±1 º ±0.1 degree/degreeAbove 65 ºC): ±1.5 % of reading

Response time <500 ms after initial reading

Spectral Response 8-14 microns

Emissivity Pre-set for foodservice applications

Distance to spot size/Optical Resolution(D:S)

2.5:1 @ 90 % energy, typical

Typical working range(target illumination)

≈25 mm to 250 mm

Minimum target size 12 mm ø

Illumination to IR channel offset

13 mm

Probe Specifications (FoodPro Plus)

Temperature FoodPro Plus -40 ºC to 200 ºC

Accuracy (Assumes ambient operating temperature of 23 ºC ±2º)FoodPro Plus Between –5 ºC and 65 ºC : ±0.5 ºC

Below –5 ºC : ±1 ºCAbove 65 ºC: ±1 % of reading

Response time FoodPro Plus 7-8 secons (3 time constants)

Probe dimensions FoodPro Plus Diameter: 3.0 mmLength: 90 mm

Sensor type FoodPro Plus Thin-film platinum, class A, ResistanceThermal device (RTD)

Operational Specifications (both)

Repeatability Within accuracy specifications of the unit

Ambient operating range 0 ºC to 50 ºC

Relative Humidity 90 % (+/- 5 %) RH non condensing @ 30 ºC

Storage Temperature -20 ºC to 60 ºC

Weight FoodPro 100 g (with battery)FoodPro Plus 150 g (with battery)

Dimensions FoodPro 150 mm x 30 mm x50 mmFoodPro Plus 165 mm x 32 mm x 50 mm

Power, battery life FoodPro 1 AA alkalineFoodPro Plus 9 V alkaline

Battery Life alkaline 10 hours minimum @ 23 ºC

Target illumination High Brightness LED

ValueTronics International, Inc. - www.valuetronics.com - 1.800.552.8258 or 1.847.468.8258888-610-7664910-442-2164 (local)

At calibration geometry of 279 mm with a 140 mm diameter, 0/97 emissivity blackbody.

Specifications subject to change without notice.

Display Resolution FoodPro 4 digits, 0.2 ºCFoodPro Plus 4 digits, 0.1 ºC

Displayhold (7seconds) FoodPro yesFoodPro Plus yes

LCD backlit display FoodPro noFoodPro Plus yes

Temperature display FoodPro 4 digits, 0.2 ºC resolutionFoodPro Plus 4 digits, 0.1 ºC resolution

Maximum temperature displayed

FoodPro noFoodPro Plus yes

Timer FoodPro noFoodPro Plus yes

Environmental Data IP54 sealing (hand-washable, non-submersible)

Other Specifications (both)

Calibration Certificate

FoodPro Plus Calibration accuracy with NIST and DKD traceability

Standards Conforms to EN 61236-1 Electromagnetic Emissions and Susceptibility, EN 6101-1 General Safety, Sealing IP54 (hand washable, non-submersible)

Certifications CE NSF

Warranty 2 years

Options/Accessories FoodPro Plus Replacement probe

Shop for Fluke products online at: 1.877.766.5412www.MyFlukeStore.ca

Page 39: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

FoodPro and FoodPro Plus Food Safety ThermometersFluke FoodPro Food Safety Thermometer

The easy-to-use and highly accurate Fluke FoodPro non-contact thermometer instantly measures surface temperature, allowing users to make rapid and frequent non-contact temperature measurements without risk of cross contamination.

Fluke FoodPro Plus Food Safety Thermometer

The Fluke FoodPro Plus combines an infrared non-contact thermometer for surface scaprobe thermometer for internal temperature readings. An integrated countdown timer wimonitors line checks as well as cooking and cooling intervals.

Includes all of the FoodPro features, plus the following:

Infrared temperature range from -35 to 275 ºCHACCP check lights for instant recognition of safe/unsafe temperaturesLED target illumination highlights the entire measurement spot for accurate targeHand washable (IP54 sealed)

Built-in fold-out probe for measuring internal food temperaturesProbe temperature range -40 to 200 ºCCountdown timer to monitor cooking, cooling and HACCP exposure timesBacklit display for clear readings in poorly lit areasMAX temperature displayed for quick reference

Shop for Fluke products online at: 1.877.766.5412www.MyFlukeStore.ca

Page 40: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 41: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 42: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 43: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

P

T

W

15

10.5 32

102

TactileBarrier

23.518.5

12.8

LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.

Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.

Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands

11/99

®

1A/10A Current Clamp Set

Instruction Sheet

Introduction The 1A/10A Current Clamp Sets (the Clamp) have been designed for applications with Fluke 1735 and 1740 series products for accurate non-intrusive measurement of ac currents. Using latest technologies (integrated memory for calibration data) provides current ranges from 0.025 A up to 10 A in a frequency range of 40 Hz to 5 kHz.

Contacting Fluke To contact Fluke, call one of the following telephone numbers:

USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 USA Service: 1-888-99-FLUKE (1-888-993-5853)

Or, visit Fluke's Web site at www.fluke.com. To register your product, visit http://register.fluke.com

Safety Instructions Please read this section carefully. It will familiarize you with the most important safety instructions for handling the Probe. In this instruction sheet, a Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and actions that may damage the calibrator or the test instruments.

WX Warning The Clamp may only be used and handled by qualified personnel. To avoid personal injury, follow these precautions: • To avoid electric shock, use caution during

installation; high voltages and currents may be present in circuit under test.

• Do not use the Clamp if damaged. Always connect to display device before it is installed around the conductor.

• Use the Clamp only as specified in the operating instructions; otherwise the safety features may not protect you.

• Adhere to local and national safety codes. Individual protective equipment must be used to prevent the shock and arc blast injury where hazardous live conductors are exposed.

• Before each use, inspect the Clamp. Look for cracks or missing portions of the housing or output cable insulation. Also look for loose or weakened components.

PN 3373012 November 2008 ©2008 Fluke Corporation, All rights reserved. Printed in The Netherlands. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

Page 44: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

• Use caution when working with voltages

above 60 V dc, 30 V ac rms or 42 V ac peak. Such voltages pose a shock hazard.

• This Clamp is considered to be used in 600 CAT III environments. CAT III equipment is designed to be used in distribution panels, feeders and short branch circuit, and the lighting system in large buildings.

• Do not use the Clamp in damp or wet environments or in locations that hazardous gases exist.

• Do not hold the Current Clamp anywhere beyond the tactile barrier.

• De-energize circuit during installation and removal of Probe.

Operating Instructions 1. Connect the Clamp to the current input jack of the

product. Verify that the product has recognized that a current Clamp is connected.

2. In case of uninsulated conductors, de-energize the circuit before placing the Clamp. Re-energize the circuit.

3. Observe and take measurements as required. Positive output indicates that the current flow is in the direction shown by the arrow on the Clamp.

4. In case of uninsulated conductors, de-energize before removal of the Clamp.

Cleaning Clean the Probe periodically by wiping it with a damp cloth and detergent. Do not use abrasive cleaners or solvents. Do not immerse the Probe in liquids.

Symbols

~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information.

W Risk of Danger. Important Information. See manual.

X Hazardous Voltage. Risk of electric shock.

T Double insulation.

- Do not apply around or remove from HAZARDOUS LIVE conductors.

) Conforms to relevant Canadian Standards Association directives.

P Conforms to relevant European Union directives.

Electrical Characteristics Nominal current In: 1 / 10 A ac rms Overload: up to 13 A rms. Max. Non-destructive current: 100 A ac rms Conductor position influence: <0.5 % of range at 50/60 Hz Error due to adjacent conductor: ≤15 mA / A at 50 Hz Phase shift at 2 kHz at 10 A: < ±1 degree Frequency range: 40 Hz to 5 kHz (-3 dB) Temperature coefficient: 0.015 % of range / °C Working voltage (see section safety): 600 V ac rms or dc Order reference:

3-phase 3024413: I1A/10A CLAMP PQ3 3-phase+N 3024424: I1A/10A CLAMP PQ4

Specifications General Specifications Maximum Conductor Size: 15 mm (0.59 in) diameter bus bar 15 x 17 mm (0.59 x 0.66 in) Cable length: 2 m (6.56 ft) Length of measuring head: 122 cm (4 ft) Operating temperature range: -10 °C to +55 °C (14 °F to 131 °F) Storage temperature range: -20 °C to +70 °C (-4 °F to 158 °F) Operating humidity (non-condensing): 15 % to 85 % rh Weight: PQ4 730 g (1.6 lb); PQ3 560 g (1.25 lb) Reference Conditions Environment temperature range: +18 °C to +26 °C (64.4 °F to 78.8 °F) Humidity: 20 to 75 % rh Altitude: max. 2000 m (1.24 mi) Current: sinusoidal waveform, 48 Hz to 65 Hz, distortion factor: <1 %, no dc component Load impedance for voltage output: ≥1 MΩ, <100 pF Safety Standards IEC/EN61010-1: 2001 IEC/EN61010-2-032:2002 IEC/EN61010-031:2002 Safety Specifications Category Rating: 600 V CAT III, pollution degree 2 EMC Standards: IEC/EN 61326-1:2006

Measurement Considerations Observe the following guidelines when making measurements: • Center the conductor inside the Clamp jaw. • Make sure the Clamp is perpendicular to the conductor. • For optimal reading, make sure the conductor is positioned

between the alignment marks on the jaws of the Clamp. • Avoid taking measurements close to other current-carrying

conductors.

Accuracy (at 50 Hz) Primary current

0.025 A to 0.5 A 0.5 A to 2.5 A 2.5 A to 5 A 5 A to 10 A

Operating error in % of reading

±2.5 % ±1.5 % ±0.5 % ±0.5 %

Phase shift Not specified <2 ° <0.5 ° <1 °

Page 45: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

i5sPQ3, 5 A ac Current Clamps, 3-pack

Specifications

Nominal current range 5 A

Continuous current range 10 mA to 6 A

Maximum Non-DestructiveCurrent

70 A

Lowest measurablecurrent

10 mA

Basic Accuracy 48 Hz to 65 Hz10 mA to 1 A 1% + 5 mA1 A to 5 A 1%

Useable frequency 40 Hz to 5 kHz

Output level(s) 400 mV/A

Input Load Impedance > 1 M in parallel with up to 47 pF

Crest Factor 3, add 0.7% to accuracy

Safety Specifications

Safety CAT III 600 V per IEC/EN61010-1, Pollution Degree 2

Maximum voltage 600 V ac

Mechanical & General Specifications

Warranty 1 year

Maximum conductordiameter

15 mm

Output cable length 2.5 m

BNC Adapter Yes

BNC to banana adapterincluded

No

A pack of 3 pieces of the i5s current clamps, specially congured to provide low current accuracy while taking measurements on secondary current transformers. This cost-saving 3-pack is perfect for use with 3-phase tools such as the Fluke 434 or Fluke 435.

Low level current clamp measures up to 5 A acCompact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches)Take accurate readings without breakings the circuitCAT III 600 V (For insulated conductors only)

Page 46: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke. Keeping your worldup and running.

Small sized, convenient to use current clamps

The i200 is a single range 200A clamp-on AC Current Clamp with current out-put via safety shrouded banana plugs.The i200 is compatible with any Flukemultimeter or any other current measure-ment device, which has banana inputs.

The i200s is a dual range 20A and 200Aclamp-on AC Current Clamp with voltageoutput via a safety insulated BNC con-nector. A dual banana to BNC adapter issupplied to allow the i200s to be con-nected to multimeters with banana input.

i200

• Measuring 0.5 to 240A

• The output signal is 1 mA/A

• Safety shrouded banana plugs forusage with DMMs or any other currentmeasuring device which has bananainputs

i200s

• Measuring range 0.1 to 24A and 0.5to 240A

• The output signal is 100 mV/A in the20A range and 10 mV/A in the 200Arange

• Includes BNC connector making itsuitable for use with any oscilloscope,power analyzer or ScopeMeter® testtool having a compatible BNC inputconnector

• Dual banana to BNC adapter isincluded for use with DMMs

i200 and i200s

• Maximum current 240A AC

• 40 Hz to 10 kHz frequency response

• Jaw opening 21 mm

• Maximum conductor size ø 20 mm orbusbar 20 x 5 mm

• EN61010, CAT III 600V

• One year warranty

i200/i200s AC Current Clamps

®

!!

!!

Ordering Informationi200 AC Current Clampi200s AC Current Clamp

Need Technical Assistance? Call:Fluke CorporationP.O. Box 9090, Everett, WA USA 98206

Fluke Europe B.V.P.O. Box 11865602 BD, EindhovenThe Netherlands

For more information call:In the U.S.A. (800) 443-5853 orFax (425) 356-5116In Europe/M-East +31 (0)40 2 678 200 orFax +31 (0)40 2 678 222In Canada (905) 890-7600 orFax (905) 890-6866From other countries +1 (425) 356-5500 orFax +1 (425) 356-5116E-mail: [email protected] access: http://www.fluke.com/nettools

© Copyright 1998 Fluke Corporation. All rightsreserved. Printed in the Netherlands 12/98.C0209 EEN Rev A.

Page 47: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke

i410/i1010

AC/DC Current Clamp

Instruction Sheet

Shown with Fluke 83 Series III DMM

Purchased in 2001 for ME/ES 308 – Instrumentation & Measurements Course.

Page 48: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 49: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 50: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 51: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage
Page 52: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 1

®

i410/i1010 AC/DC Current Clamp

Instruction Sheet

Safety Information XW Read First: Safety Information

To ensure safe operation and service of the current clamp, follow these instructions:

• Read all operating instructions before use and follow all safety instructions.

• Use the Current Clamp only as specified in the operating instructions, otherwise the clamp’s safety features may not protect you.

• Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock and arc blast injury where hazardous live conductors are exposed.

• Do not hold the Current Clamp anywhere beyond the tactile barrier. See Features and Connections.

• Before each use, inspect the Current Clamp. Look for cracks or missing portions of the clamp housing or output cable insulation. Also look for loose or weakened components. Pay particular attention to the insulation surrounding the jaws.

• Never use the clamp on a circuit with voltages higher than 600 V (CAT. III) or a frequency higher than 400 Hz (i410) or 2 kHz (i1010). • CAT III equipment is designed to protect against

transients in equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings.

• Use extreme caution when working around bare conductors or bus bars. Contact with the conductor could result in electric shock.

• Use caution when working with voltages above 60 V dc, 30 V ac rms or 42 V ac peak. Such voltages pose a shock hazard.

PN 617677 September 1996, Rev.2, 6/05 1996-2005 Fluke Corporation. All rights reserved. Printed in Thailand.

Page 53: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 2

Features and Connections

CLAMP METERi410

ZEROA

CAT 600V 600A

600V

V

76 TRUE RMS MULTIMETER

8

ar001i.eps

A Jaw Lever

B Jaw Centering Marks

C ON Indicator

D ON/OFF Switch

E Zero Adjust

F Battery Access

G Output Cable

H Tactile Barrier

Minimum voltmeter requirements:

• Accepts safety-shrouded banana plugs.

• Can display 1 mV (0.1 mV preferred)

• Accuracy ≥ 0.75 %

• Input impedance ≥ 1 MΩ, ≤100 pF.

Page 54: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 3

Measuring DC Current Maximum: 400 A dc (i410) or 1000 A dc (i1010)

CLAMP METERi410

ZEROA

600V

CAT 600V 600A

CLAMP METERi410

ZEROA

CAT 600V 600A

600V

mV

76 TRUE RMS MULTIMETER

ar002i.eps

A Connect to voltmeter.

B Select mV dc.

C Set ON.

D Adjust ZERO (jaws empty.)

ZEROA ar006i.eps

E Clamp and center around conductor.

F Read voltmeter (1 mV = 1 A.)

Page 55: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 4

Measuring AC Current Maximum: 400 A ac rms (i410) or 600 A ac rms (i1010)

01

32

4 5 678

910

Speed

CLA

MP

ME

TER

i410

ZE

RO

A

600V

CA

T

600V

60

0A

CLA

MP

ME

TER

i410

ZE

RO

A

600V

CA

T

600V

60

0A

V

76 TRUE RMS MULTIMETER

ar003i.eps

A Connect to voltmeter.

B Select mV ac (or V ac, but resolution may be limited to 1 A.)

C Set ON.

D Clamp and center around conductor.

E Read voltmeter (1 mV = 1 A.)

Page 56: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 5

Testing the Battery

CLAMP METERi410

ZEROA

CAT 600V 600A

600V

V

76 TRUE RMS MULTIMETER

ar004i.eps

A Set OFF.

B Select V dc.

C ≤ 7.0 V dc = replace battery.

(Voltmeter input impedance ≥ 1 MΩ)

Replacing the Battery For specified battery life, use an alkaline battery.

1.

2.

3.

ar005i.eps

Page 57: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 6

If the Current Clamp Does Not Work Check Correct

Battery = OK? Refer to “Testing the Battery.” Voltmeter connections? Red to + or V

Black to C Voltmeter function/range? mV dc

mV ac (or V ac)

Storage During longer periods of non-use (> 60 days), remove and store the battery separately.

Cleaning Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.

Service and Parts The Current Clamp should be serviced only by a qualified service technician. For service information, contact your nearest Fluke dealer or service center.

Symbols , May be used on HAZARDOUS LIVE conductors.

T Equipment protected by double or reinforced insulation.

W Risk of Danger. Important information. See Instruction Sheet.

X Risk of Electric Shock.

) Complies with U.S. and Canadian standards: UL61010-1; CAN/CSA C22.2 No. 61010-1 (2004) & No. 61010-2-032 (2004)

s

Inspected and licensed by TÜV Product Services.

;

N10140 Conforms to relevant Australian standards.

P Conforms to IEC 61010-1 2nd Edition & IEC 61010-02-032

J Earth ground

B AC (Alternating Current)

F DC (Direct Current)

Page 58: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 7

Specifications Operating Temperature -10 °C to +50 °C (14 °F to 122 °F) Storage Temperature -20 °C to +60 °C (-4 °F to +140 °F) Relative Humidity 0 % to 95 % (0 °C to 30 °C)

0 % to 75 % (30 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C)

Altitude Operating Non-operating

0 m – 2000 m 0 m – 12000 m

Battery Type 9 V (alkaline) NEDA 1604 IEC 6F22 Battery Life 60 hrs typical (continuous with alkaline) Safety s Double Insulation, 600 V rms, CAT. III Current x Hz Product ≤ 240,000 Output Signal 1 mV per amp dc or ac Working Voltage 600 V rms, CAT. III maximum at input Maximum Conductor Size 1 ea. 30 mm (1.18 in.) diameter

2 ea. 25 mm (0.98 in.) diameter Load Impedance ≥1 MΩ, ≤100 pF Temperature Coefficient +/-(0.05 x accuracy per °C (0 °C – 18 °C,

28 °C – 50 °C) Size 209 mm x 78 mm x 48 mm

(3.09 in. x 8.21 in. x 1.87 in.) Weight 0.5 kg (17.6 oz.)

i410 i1010

Specified Current Range:

1 A – 400 A ac rms * 1 A – 400 A dc

1 A – 600 A ac rms * 1 A – 1000 A dc

Usable Current Range:

0.5 A – 400 A 0.5 A – 1000 A

DC Accuracy (zero adjusted, conductor centered)

3.5 % + 0.5 A (0 A – 400 A)

2.0 % + 0.5 A (0 A – 1000 A)

AC Accuracy

3.5 % + 0.5 A, 45 Hz – 400 Hz, Crest Factor ≤ 3. (0 A – 400 A)

2.0 % + 0.5 A, 45 Hz – 400 Hz, Crest Factor ≤ 3. 3.0 % + 0.5 A, 400 Hz - 2 kHz sine wave. (0 A – 600 A)

Bandwidth 3 kHz 10 kHz

* With a true-rms voltmeter, the minimum ac current is limited to the low end of the specified mV ac range.

Page 59: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 8

LIMITED WARRANTY & LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption.

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country.

Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.

Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands

11/99

Page 60: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

I410/i1010 English Panel 9

Page 61: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Technical Data

Fluke i2000 FlexAC Current Clamp

Electrical specificationsCurrent ranges: 20 A, 200 A, 2000 A ACRMSOutput sensitivity (ac-coupled): 100 mV, 10 mV, 1 mV per ALoad impedance: 100 kW minimumAccuracy (at +25 °C): ± 1 % of range (45 Hz to 65 Hz)Linearity (10 % to 100 % of range): ± 0.2 % of readingNoise: 8 mV ac rms (30 A), 2 mV ac rms (300 A, 3000 A)Frequency range: 10 Hz to 20 kHz (-3 dB)Phase error: < ± 1 º (45 Hz to 65 Hz), : ± 10 º (at 20 kHz)Position sensitivity (with cable > 25 mm from the coupling): ± 2 % of rangeExternal field (with cable > 200 mm from the head): ± 1 % of range

The i2000 is an ac current probe Utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Power supply: 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicatorTemperature coefficient: ± 0.08 % of reading per °CWorking voltage (see Safety standards section): 600 V ac rms or dc

General specificationsHead cable length (double insulated): 610 mm (24 in)Head cable diameter: 14.3 mm (0.56 in)Head bend radius: 38.1 mm (1.5 in)Cable length (head to electronics): 2 m (6.56 ft)Output connection: BNC with BNC to Banana adapter includedOperating temperature range: 0 °C to +70 °C (32 °F to 158 °F) (head and electronics)

Page 62: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Storage temperature range: -40 °C to +105 °C (-40 °F to 221 °F) (head), -20 °C to +85 °C (-4 °F to 185 °F) (electronics)Operating humidity: 15 % to 85 % (non-condensing)Weight: 180 g (6.34 oz) (head), 190 g (6.70 oz) (electronics)

Safety standardsEN 61010-1: 2001EN 61010-2-032: 2002EN 61010-031: 2002

600 Vrms, Category III, Pollution Degree 2Use of the probe on uninsulated conductors is limited to 600 V acrms or dc and frequencies below 1 kHz.

EMC StandardsEN 61326: 1998 +A1, A2, & A3

Fluke Corporation PO Box 9090, Everett, WA USA 98206

Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands

For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2 675 200 or Fax +31 (0) 40 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com

©2006 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 12/2006 2688061 D-EN-N Rev D

Fluke.Keeping your world up and running.™

Ordering informationi2000 Flex AC Current Clamp

i2000 Flex connected to a Fluke 87V Digital Multimeter.

Page 63: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Technical Data

Fluke i3000s FlexAC Current Clamp

Electrical specificationsCurrent ranges: 30 A, 300 A, 3000 A ac rms Output sensitivity (ac-coupled): 100 mV, 10 mV, 1 mV per ALoad impedance: 100 kW minimumAccuracy (at +25 °C): ± 1 % of range (45 Hz to 65 Hz)Linearity (10 % to 100 % of range): ± 0.2 % of reading Noise: 8 mV ac rms (30 A), 2 mV ac rms (300 A, 3000 A)Frequency range: 10 Hz to 50 kHz (-3 dB)Phase error: < ± 1º (45 Hz to 65 Hz), ± 10º (at 20 kHz)Position sensitivity (with cable > 25 mm from the coupling): ± 2 % of rangeExternal field (with cable > 200 mm from the head): ± 1 % of range

The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Power supply: 2 x AA MN 1500 LR6 alkaline, 400 hours, low battery indicatorTemperature coefficient: ± 0.08 % of reading per °CWorking voltage (see Safety Standards section): 600 V ac rms or dc

General specificationsHead cable length (double insulated): 610 mm (24 in) i3000s Flex-24915 mm (36 in) i3000s Flex-36Head cable diameter: 14.3 mmHead bend radius: 38.1 mmCable length (head to electronics): 2 metersOutput connection: 0.5 m cable terminated with safety BNC connector. Supplied with BNC to Banana safety plug adapter.

Page 64: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Operating temperature range: -20 °C to +90 °C (-4 °F to 190 °F) (head), -20 °C to +85 °C (-4 °F to 185 °F) (electronics)Storage temperature range: -40 °C to +105 °C (-40 °F to 221 °F) (head), -20 °C to +85 °C (-4 °F to 185 °F) (electronics)Operating humidity: 15 % to 85 % (non-condensing)Weight: 180 g (0.396 lb) (head), 190 g (0.419 lb) (electronics)

Safety standardsBS EN 61010-1: 2001BS EN 61010-2-032: 2002BS EN 61010-031: 2002

600 Vrms, Category III, Pollution Degree 2Use of the probe on uninsulated conductors is limited to 600 V acrms or dc and frequencies below 1 kHz.

EMC StandardsEN 61326: 1998 +A1, A2, & A3

Fluke Corporation PO Box 9090, Everett, WA USA 98206

Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands

For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com

©2006 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 12/2006 2747103 D-EN-N Rev C

Fluke.Keeping your world up and running.™

Ordering information

i3000s FLEX-24 AC Current Probe, 24-inch circumference

i3000s FLEX-36 AC Current Probe, 36-inch circumference

i3000 FLEX-4PK, AC Current Probe, 4-pack of i3000s FLEX-24

Optional Accessories

FLEX PSU-EU Power supply unit for Europe

FLEX PSU-UK Power supply unit for the United Kingdom

Note: Power supply units only available for Europe and the United Kingdom.

i3000s Flex connected to a Fluke 434 Power Quality Analyzer (The i430 FLEX-4PK can be used with the Fluke 434 and 435, without the need for the control box).

i3000s Flex connected to a Fluke 199C ScopeMeter.

Page 65: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke L207 High Intensity Light with Collector's Cap

Overview: Powerful, lightweight, mini-Xenon worklight shines right where you're working. Comes with limited edition Fluke collector's cap.

Features:

o Cap adjusts for all-day comfort o Light attaches to bill of baseball cap o Rugged light withstands 6' drops to concrete o Waterproof light case won't crack or chip o Electrically and thermally nonconductive

Model Name Description

Fluke L207 Fluke L207 High Intensity Light with Collector's Cap

Page 66: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Accessories > Lights >

LVD2 Volt LightNon-contact AC voltage detector and LED flashlight combined into one easy to use pen-style design. The LVD2 is a CAT IV 600 V rated non-contact detector that is suitable for commercial and industrial applications. The LVD2 includes dual sensitivity turning blue 1” to 5” (2.54 cm to 12.7 cm) from the source and red when at the source.

Dual Sensitivity LED light with 100,000 hour life Detects from 90 to 600 V AC Rated to CAT IV 600 V Dual Levels of Detection Blue indicates proximity to AC Voltage

source Red indicates you’re at the source Operating temperature 0 deg C to 50

deg C Ultra-Bright White LED 100,000 hr bulb AAA battery included

Model Name Description LVD2 Volt Light

Page 67: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Technical Data

Overview

AirCheck integrates all Wi-Fi technologies

plus interference detection, channel scan-

ning, and connectivity tests. Quickly trouble-

shoot the most common Wi-Fi pain points,

including:

Coverage problems •

Overloaded networks or channels •

Interference •

Connectivity problems •

Failed access points•

Rogue access points •

Security settings •

Client problems •

In addition to generating instant reports and

documentation, AirCheck Manager software

allows you to set up multiple profiles and

manage network and security settings for

a single unit, or an entire fleet of AirCheck

testers.

AirCheck Features

Supports 802.11a/b/g/n – All in one

handheld tool.

Instant-on operation – Powers up in less

than three seconds and automatically starts

discovering networks, access points (APs),

and channel activity.

Get answers fast – Intuitive user interface

quickly gives you the answers you need in

one or two button presses and displays the

information on a bright color display.

Identifies security settings for each

Network and Access Point: Open, WEP, WPA,

WPA2, and/or 802.1x.

Pinpoints Wi-Fi traffic and interference –

Shows how much of each channel’s bandwidth

is consumed by 802.11 traffic and interfer-

ence, and the APs using each channel.

Finds rogue APs – Flags unauthorized APs.

Helps you hunt them down with the LOCATE

function or find them even faster with the

optional directional antenna.

Wi-Fi Troubleshooting Made Simple

A i r C h e c k ™ W i - F i Te s t e r

Wi-Fi is a complex technology,

but testing it doesn’t have to be.

The AirCheck Wi-Fi tester allows

network professionals to quickly

verify and troubleshoot

802.11 a/b/g/n networks.

Designed specifically for dispatched

troubleshooting, AirCheck simplifies

wireless testing by providing:

Just a few clicks to the answers •you need with streamlined, guided troubleshooting

An instant view to required •test results including network availability, connectivity, utilization, security settings, rogue hunting, and interfer-ence detection

A rugged, purpose-built wi-fi •tester that’s easy to use and easy to carry

Its intuitive design makes it

simple for anyone to quickly master

AirCheck. Instant power-up and

streamlined tests give answers in sec-

onds so you can close trouble tickets

faster – making technicians and users

alike more productive. Easily manage

test results and documentation using

AirCheck Manager software. From

start to finish, AirCheck helps take

the guesswork out of everyday

wireless troubleshooting.

Page 68: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Connection tests – Connects to networks

or specific APs using WEP, WPA, WPA2,

and/or 802.1x. Acquires an IP address and

pings the router, gateway, and user-defined

addresses to verify connectivity and network

access inside and outside the firewall.

Verifies connection quality.

Designed for the field – Five-hour battery

life. One-handed operation. Rugged design.

Documents results – Saves complete

results of the current troubleshooting

session for download to your PC with the

push of a button.

Easy upgrades – The mini-USB port allows

software upgrades in the field in just

minutes. And with Gold support, you’ll

automatically receive upgrades at no

additional charge.

AirCheck FunctionsList NetworksFind security issues, rogue APs and coverage problems and view a list of all wireless networks heard by AirCheck. Instantly see the following for each network:

Signal level•Security / encryption•Number of APs in network•SSID name•Type of network •

AirCheck displays networks that it can no longer “hear” in a gray font.

List Access PointsFind configuration and coverage problems as well as rogue APs. View a list of all physical APs heard by AirCheck including the following information:

Channel•Signal level•AP name or MAC address•SSID name (or count of SSIDs for virtual •APs)Security / encryption•Type of network •

Channel UsageQuickly determine if channels are overloaded due to Wi-Fi traffic (displayed in blue) or interference (displayed in gray). Verify channel-usage pattern or overlap and flag illegal use of channels.

With AirCheck, you can also detect the presence of interference. Devices that can cause interfer-ence include microwave ovens, cordless phones and headsets, BlueTooth® devices, and analog video cameras.

Channel Usage DetailsFind overloaded channels and interference. Drill in further to see the level of Wi-Fi traffic and interference over the last 60 seconds on a selected channel, as well as the access points using this channel.

Access Control SettingsQuickly determine which access points are known and which are not by setting the authorization status for each AP seen by AirCheck. You may also define access control settings in AirCheck Manager and download them in a profile.

Page 69: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Locate Access PointsTrack down rogue and other APs by graphing the signal strength over time, or by using an audible indication which can be muted.

Access Point DetailsQuickly identify AP configuration problems. View the following information for each physical AP:

Signal / noise/ signal-to-noise ratio •(current and max)SSID and BSSID•ACL status•Security / encryption•

ConnectVerify network availability and access by connecting to a network (SSID) or specified AP using three simple steps:

Associate with AP•Request IP address from DHCP server •PING gateway, DHCP server and •user-defined addresses

View the process steps on the display and store them in a log for troubleshooting. Quickly test performance and quality of the connection by using the continuous ping response, loss-rate, and connection-range features.

List Probing ClientsFind misconfigured or failed client devices and view a list of all probing devices by MAC address and sig-nal strength. Does not display associated clients.

AirCheck Manager SoftwareThis software is included with AirCheck and provides two capabilities: the ability to manage AirCheck profiles and manage sessions recorded with AirCheck.

Profiles Easily configure, manage, and control the use of your AirCheck – or an entire fleet of them - with the Profiles feature, which includes the following settings:

Network configuration settings, including •IP addressing and security / encryptionConnectivity test settings, including target •test devicesPassword protection for all settings•

Name and transfer multiple profiles into AirCheck, as needed for different facilities. You can also transfer profiles from AirCheck to AirCheck Manager software.

Profiles are password protected, both in AirCheck and in AirCheck Manager, eliminating worry about unauthorized access to your network if your AirCheck is lost or stolen.

Record SessionDocument what AirCheck is seeing to share or archive. Create summary or detailed reports allowing you to quickly close a trouble ticket or provide documentation for problem escalation. Press one key to record all collected details for:

AirCheck configuration•Access points•Probing clients•Channel usage•Connection details•

Transfer sessions to a PC and easily view/store them using AirCheck Manager software.

AirCheck Manager Software

Page 70: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

N E T W O R K S U P E R V I S I O N

Fluke NetworksP.O. Box 777, Everett, WA USA 98206-0777

Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact.

©2009 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2010 3594200A D-ENG-N

Wi-Fi® is a registered trademark of the WiFi Alliance.

AirCheck Manager Software

Supported operating systems Windows Vista; Windows XP; Windows 7

Processor 400 MHz Pentium processor or equivalent (minimum); 1 GHz Pentium processor or equivalent (recommended)

RAM 96 MB (minimum); 256 MB (recommended)

Hard disk Up to 500 MB of available space may be required

Display 1024 x 768 high color, 32-bit (recommended)

Hardware USB Port

Technical Specifications

Environmental

Operating temperature and relative humidity

32ºF to 113ºF (0ºC to +45ºC)Note: The battery will not charge if the internal temperature of the tester is above 104ºF (35ºC)

Operating relative humidity (% RH without condensation)

90% (50ºF to 95ºF; 10ºC to 35ºC)75% (95ºF to 113ºF; 35ºC to 45ºC)

Storage temperature -4ºF to 140ºF (-20ºC to +60ºC)

Shock and vibration Random, 2 g, 5 Hz-500 Hz (Class 2) 1 m drop test

Safety EN 61010-1 2nd edition

Altitude 4,000 m; Storage: 12,000 m

EMC FCC Part 15 Class A, EN 61326-1

Certifications and compliance

P Conforms to relevant European Union directives

; Conforms to relevant Australian standards

$ Listed by the Canadian Standards Association

Conforms to FCC Rules, Parts 15.107, 15.109

Wireless

Specification compliance

IEEE 802.11a, 11b, 11g, 11n

Operating frequencies

EEE 802.11a ISM Band USA (FCC): 5.15 GHz to 5.25 GHz; 5.725 GHz to 5.850 GHz Europe (ETSI): 5.15 GHz to 5.25 GHz Japan (TELEC): 5.15 GHz to 5.35 GHz; 5.47 GHz to 5.725 GHz

IEEE 802.11b/g ISM Band USA (FCC): 2.412 GHz to 2.462 GHz (channel 1 to channel 11) Europe (ETSI): 2.412 GHz to 2.472 GHz (channel 1 to channel 13) Japan (TELEC): 2.412 GHz to 2.472 GHz (channel 1 to channel 13)

IEEE 802.11gn 40 MHz Band USA (FCC): 2.422 GHz to 2.452 GHz Europe (ETSI): 2.422 GHz to 2.462 GHz Japan (TELEC): 2.422 GHz to 2.462 GHz

IEEE 802.11an 40 MHz Band USA (FCC): 5.15 GHz to 5.25 GHz; 5.725 GHz to 5.850 GHz Europe (ETSI): 5.15 GHz to 5.25 GHz Japan (TELEC): 5.15 GHz to 5.35 GHz; 5.47 GHz to 5.725 GHz

Regulatory domain

World Mode, 802.11d compliant

External uni-directional antenna

Frequency range: 2.4 GHz to 2.5 GHz and 4.9 GHz to 5.9 GHz; Minimum gain: 5.0 dBi in the 2.4 GHz band and 7.0 dBi in the 5 GHz bandConnector: Reverse-polarity SMA plug

General

Dimensions 3.5 in x 7.8 in x 1.9 in (8.9 cm x 19.8 cm x 4.8 cm)

Weight 14 oz (0.4 kg)

Battery Removable, rechargeable lithium-ion battery pack (18.5 Watt-hrs)

Battery life Typical operating life is 5.5 hours; Typical charge time is 3 hours

External AC adapter/charger

AC input 90 to 264 Vac 48 to 62 Hz input power DC output 15 Vdc at 1.2 amps

Display 2.8 in color LCD (320 x 240 pixels)

Keypad 12-key elastomeric

LEDs 2 LEDs (transmit and link Indicators)

Host interface USB 5-pin mini-B

Wireless antenna Internal

External antenna port

Input only; Reverse-polarity SMA connector

Ordering Information

Model Description

AirCheck

AirCheck Wi-Fi Tester includes: AirCheck tester, USB cable, soft case, Getting Started Guide, and CD with AirCheck Manager software and User Manual

ACK-LRPRO

AirCheck Frontline Troubleshooting Kit with LRPRO includes: AirCheck tester, External uni-directional antenna, USB cable, carry-ing case, Getting Started Guide, and CD with AirCheck Manager software and User Manual, LinkRunner Pro Standard Kit, and PoE detector.

EXTANT-RPSMA External uni-directional antenna, RSMA connector

WBP-LION AirCheck Lithium Ion replacement battery

POE-Detector Power over Ethernet detector

MS-Auto-Ch Auto charger

DTX-ACUN AC charger, universal

GLD-ACK AirCheck Gold support services, 1 yr

Page 71: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Technical Data

LinkRunner™ Network Multimeter

Quickly verify and troubleshoot network drops with this essential, personal tool.

Frontline PC and network technicians

are the first line of defense against

problems at the physical and link lay-

ers of the network. Typical problems

the technician checks for include

determining whether the drop is active,

whether they can “ping” other network

resources, finding any cable problems

and tracing the cable path.

Designed for the frontline technician,

LinkRunner improves troubleshooting

and escalation accuracy by helping to

quickly identify if a problem is in the

network or the PC NIC. LinkRunner

performs essential tests for trouble-

shooting and solving problems in the

physical and link layers, the source of

80% of network problems.

Instant vision into the network drop.

That’s Network SuperVision.™ That’s

Fluke Networks’ promise to you.

LinkRunner helps you answer questions like:

• IsthisanactiveEthernetport?

• Whatspeed/duplexisthehub/switch/PCNICconfiguredfor?

• AmIseeingtrafficfromthisconnection?

• IsthePCNICokay?

• Wheredoesthecablego?

• AmIconnectedtotheInternet?

Perform the following tests quicklyLink–determinewhetherthedropisactive,identifyitsspeed,duplexcapabilities,servicetype(e.g.,Ethernet,Tokenring,Telco),andlocationonaswitch(supportsCiscoandExtremeDiscoveryProtocols).UserscanthenreconfigurethesesettingsonthehuborNICasneeded.NowdetectsuptoGigabitEthernet.

Length–determinewhetherthecablelengthiswithinspecifications,whattypeitis(straightorcrossover),andwhetherithasanyfaults.Thesetests,whichworkforbothstructuredandpatchcables,eliminatetheneedforaseparatecabletester.

Ping–verifyconnectivitytokeynetworkresourcesanddeterminewhetheraPCNICisresponding.

Actual size.

Drop Switch

See device capabilities, actual

link speed, and utilization levels.

Precisely locate switch ports

with Cisco Discovery Protocol.

Ping DNS server or key devices,

and observe response time.

Page 72: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Ordering Information

Model Name Description

LINKRUNNER LinkRunnerNetworkMultimeter

LINKRUNNER-KIT LinkRunnerextendedtest(includesLinkRunnerandallaccessorieslistedbelowincludingcustomcarryingcase)

CIQ-SVC CableIQServiceKit(includesCableIQQualificationTesterwithcableIDnumbers1-7,LinkRunnerNetworkMultimeter,andIntelliTone200Probe)

CABLEIDKIT CableIDKit(numbers1-8)

LRUN-WM WiremapAdapter

RJ-45COUPLER RJ-45Coupler

MT-8200-53A IntelliTone100Probe

CLIPSET Clipadaptertotestunterminatedcables

BATT-AA-NIMH NiMHBatteryPack

NT-BATT-CHG NiMHBatteryCharger

LR-CASE CustomCarryingCaseforLinkRunnerExtendedTestKit

PC-INSP PCInspector

Fluke NetworksP.O.Box777,Everett,WAUSA98206-0777

Fluke Networks operatesinmorethan50countriesworldwide.Tofindyourlocalofficecontactdetails,gotowww.flukenetworks.com/contact.

©2005FlukeCorporation.Allrightsreserved.PrintedinU.S.A.4/20061995782D-ENG-NRevF

N E T W O R K S U P E R V I S I O N

Visit www.flukenetworks.com/linkrunner

and www.flukenetworks.com/keydevice

for more information.

LinkRunner Extended Test Kit Includes:

Allavailable

accessoriesandthe

customcarryingcase

FREE belt clip holster when you register your LinkRunner

Specifications

Mediaaccess 10BASE-Tand100BASE-TX

Identifies 10BASE-T,100BASE-TX(fullorhalf-duplex),GigabitEthernet,TokenRing,

Telco,CableID,un-poweredPCorhub,Auto-MDIXportsandAuto-Negotiation

orstrappedport

Cabletests Length,open,short,splits,wiremap,crossed,straightthrough

Ports RJ-45LAN,RJ-45Wiremap

Interface Pushbuttonnavigationoficon/menudrivenview

Power 2AAbatteriesstandard.OptionalNiMHbatteriesandbatterychargeravailable.

Approximately20hourscontinuoususewith4hoursofpinging.

Dimensions 2.75”wx3.75”hx1.25”d(6.98cmx9.52cmx3.17cm)

Weight 4.5oz/128gramswithbatteriesinstalled

Warranty Oneyear

CableIQ Service Kit Includes:

Allessentialcablequalificationandnetworkverificationtools.

Page 73: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

TM

i

MICROMAPPER™

LAN Wiremap Checker

Users Manual

(English)November 2001, Rev. 2, 9/03© 2001-2003 Fluke Corporation. All rights reserved.All product names are trademarks of their respective companies.

Page 74: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

LIMITED WARRANTY AND LIMITATION OF LIABILITYEach Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service. The warrantyperiod is one year and begins on the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days. This war-ranty extends only to the original buyer or end-user customer of a Fluke Networks authorized reseller, and does not apply to disposablebatteries, cable connector tabs, cable insulation-displacement connectors, or to any product which, in Fluke Networks’ opinion, has beenmisused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke Networks war-rants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly re-corded on non-defective media. Fluke Networks does not warrant that software will be error free or operate without interruption.Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user customers only but have noauthority to extend a greater or different warranty on behalf of Fluke Networks. Warranty support is available only if product is purchasedthrough a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price. Fluke Networks reserves the right toinvoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in anothercountry.Fluke Networks’ warranty obligation is limited, at Fluke Networks’ option, to refund of the purchase price, free of charge repair, or replace-ment of a defective product which is returned to a Fluke Networks authorized service center within the warranty period.To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, thensend the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke Net-works assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOBDestination). If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormalcondition of operation or handling, or normal wear and tear of mechanical components, Fluke Networks will provide an estimate of repaircosts and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportationprepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDINGBUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALLNOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISINGFROM ANY CAUSE OR THEORY.Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or conse-quential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is heldinvalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforce-ability of any other provision.

6/01 Fluke NetworksPO Box 777Everett, WA 98206-0777USA

Page 75: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

i

Table of Contents

Title Page

Introduction .................................................................................................................... 1Features .......................................................................................................................... 2MICROMAPPER Kit Content ................................................................................................ 2Registration..................................................................................................................... 2Safety Information........................................................................................................... 3Contacting Fluke Networks.............................................................................................. 3MICROMAPPER Controls and LEDs ...................................................................................... 4Battery ............................................................................................................................ 5MICROMAPPER’s Toner Operation....................................................................................... 5MicroMapper Tests.......................................................................................................... 6Fault Status ..................................................................................................................... 7Technical Specifications ................................................................................................... 9

Page 76: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapperUsers Manual

ii

Page 77: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

1

MICROMAPPER™

Introduction

Congratulations on your purchase of theMICROMAPPER network cable tester!

The MICROMAPPER is a hand-held cable tester thatenables network professionals to quickly and easilyverify the integrity of Ethernet twisted pair cables. Inone step, the MICROMAPPER will test twisted paircabling for opens, shorts, reversed, crossed, and splitpairs. Simply slide the switch to the Cable position,press the (TEST) button and the MICROMAPPER willautomatically scan for any existing faults in your cable.The specially designed remote unit is provided forone-person testing of installed cabling. The tonegenerator function can be used with the MicroProbecable tracer to trace cables and locate cables hidden inceilings, walls, floors, and bundles.

Page 78: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapperUser’s Manual

2

Features

• Tests for wiring faults and detects opens, shorts,crossed, reversed, and split pairs. (Split pair faultdetection requires a minimum cable length of15.75" (40cm))

• Verifies shield integrity

• MICROMAPPER’s Remote Identifier enables oneperson to test installed cabling

• Easy to read fault display and high speed testing

• Generation of two tones for tracing cables andlocating hidden cables

• Debug-mode for detailed fault identificationresults

• Auto-sleep mode to decrease power consumption

MICROMAPPER Kit Content

Your MICROMAPPER kit contains the following:

• 1 MICROMAPPER network cable tester

• 1 MICROMAPPER remote

• Patch cord

• Quick Reference Guide

• Product Manuals CD

Registration

Registering your product with Fluke Networks givesyou access to valuable information on product updates,troubleshooting tips, and other support services.

To register, fill out the online registration form on theFluke Networks website atwww.flukenetworks.com/registration. If you do nothave Internet access, print the registration form fromthe CD included with the product. Fill out the form,then mail or fax it to the appropriate address for yourcountry.

Page 79: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapper™Safety Information

3

Safety Information

WarningsDo not connect MICROMAPPER to a livecircuit as it may damage the unit.

Do not open the unit or attempt to repairin case of malfunction. Please send itback to your distributor for repair orreplacement.

CautionStrong radio frequency fields may causeinaccurate readings.

Do not drop or get the unit wet. Do notexpose MICROMAPPER to extreme humidityor direct sunlight.

Contacting Fluke Networkswww.flukenetworks.com

[email protected]

+1-425-446-4519

• Australia: 61 (2) 8850-3333 or 61 3 9329 0244

• Beijing: 86 (10) 6512-3435

• Brazil: 11 3044 1277

• Canada: 1-800-363-5853

• Europe: +44 1923 281 300

• Hong Kong: 852 2721-3228

• Japan: +81-3-3434-0181

• Korea: 82 2 539-6311

• Singapore: +65-6738-5655

• Taiwan: (886) 2-227-83199

• USA: 1-800-283-5853

Visit our website at www.flukenetworks.com for acomplete list of phone numbers.

Page 80: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapperUser’s Manual

4

MICROMAPPER Controls and LEDs

1-2 3-6 4-5 7-8 SHIELD

SHORTTONER

TEST REVERSED

MISWIRE

SPLIT PAIRS

LOW BATTERY

REMOTE

MICROMAPPER

atx02f.eps

Figure 1. MICROMAPPER Network Cable Tester

Table 1. MICROMAPPER Controls and LEDs

ItemNumber

Description

Pair and Shield Indicator LEDs

Toner LED

TEST button

REMOTE Adapter with RJ45 Jack

RJ45 Jack

Off/Cable/Toner Switch

Fault LEDs

Low Battery LED

Page 81: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapper™Battery

5

Battery

MICROMAPPER requires four 1.5 AAA batteries. IEC :LR03. Others : AAA, E92, 4003; JIS : AM 4 ; ANSI : 24A;1.5 Volt (nominal).

atx03s.bmp

The Battery LED will light up when MICROMAPPER

detects a low battery condition. Using MICROMAPPER

with a low battery may affect the test accuracy. IfMICROMAPPER is stored for more than a month, thebattery should be removed.

MICROMAPPER’s Toner Operation

1. Slide the switch on the right side of MICROMAPPER

to the Toner position.

2. Connect the cable to the MICROMAPPER’s RJ45 jack.(To send a tone into a patch panel, connect oneend of the included patch cord to theMICROMAPPER’s RJ45 jack and the other end to ajack on the panel.)

3. To generate tone 1, press and quickly release the

(TEST) button.

4. To generate tone 2, press and hold the (TEST)button for two seconds.

5. Use the MICROPROBE to trace the connected cable.The signal reception is strongest near the cableunder test.

6. Slide the switch on the right side to the Offposition to discontinue the tone. (Always powerthe unit off to prevent battery drain.)

Page 82: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapperUser’s Manual

6

MICROMAPPER Tests

1. Slide the switch on the right side to the Cableposition to turn MICROMAPPER on.

2. Connect one end of the cable to be tested to theMICROMAPPER’s RJ45 jack.

3. Connect the other end of the cable to theMICROMAPPEr Remote’s RJ45 jack.

4. Press (TEST) to view the results.

5. The horizontal LEDs indicate the cable’s integritystatus.

• Green: Pair or Shield is good

• Green flashing: Pair or Shield is faulty

• No light: Pair is open or cable is not shielded

The vertical LEDs indicate the wiring faults and alow battery status. Wiring faults are: SHORT,REVERSED, MISWIRE, SPLIT PAIRS.

6. To find out a fault on a specific pair, useMICROMAPPER’s diagnostic feature.

7. Press and hold (TEST) for more than 2 seconds.

MICROMAPPER will scan each pair and the shieldpausing and flashing each green LED separately. Ifa faulty pair is detected, the corresponding faultstatus will blink in red.

Note

Push the Remote Terminator onto theMicroMapper until it snaps into position. Thisconfiguration allows you to conveniently testpatch cables.

Page 83: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapper™Fault Status

7

Fault Status

SHORT

TEST

TONERSHORT

REVERSED

MISWIRE

SPLIT PAIRS

LOW BATTERY

1-2 3-6 4-5 7-8 SHIELD

12364578

12364578

S S

OPEN

12364578

12364578

S S

1-2 3-6 4-5 7-8 SHIELD

TEST

TONERSHORT

REVERSED

MISWIRE

SPLIT PAIRS

LOW BATTERY

Page 84: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapperUser’s Manual

8

REVERSED

12364578S

12364578S

TEST

TONERSHORT

REVERSED

MISWIRE

SPLIT PAIRS

LOW BATTERY

1-2 3-6 4-5 7-8 SHIELD

MIS-WIRE

TEST

TONERSHORT

REVERSED

MISWIRE

SPLIT PAIRS

LOW BATTERY

1-2 3-6 4-5 7-8 SHIELD

12364578S

12364578S

SPLIT PAIR

TEST

TONERSHORT

REVERSED

MISWIRE

SPLIT PAIRS

LOW BATTERY

1-2 3-6 4-5 7-8 SHIELD

12364578S

12364578S

Page 85: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapper™

9

Technical Specifications

Connectors

MICROMAPPER main unit: RJ45 jack

Remote Identifier: RJ 45 jack

Pairs tested

1-2, 3-6, 4-5, 7-8, and shield

LED Display

Horizontal: 5 green LEDs for pairs and shielddisplay(1 - 2, 3 - 6, 4 - 5, 7 - 8, and SHIELD)

Vertical: 6 red LEDs (TONER, SHORT, REVERSED,MISWIRE, SPLIT PAIRS, and LOW BATTERY)

Cables test limit

Minimum: 15.75" (40cm); Maximum: 656’ (200 m)

Power

IEC 86-1 (1996-07) --- Primary Batteries - General

IEC 60086-2 (1997-07) --- Primary Batteries -Specification Sheets

MICROMAPPER: requires four 1.5 AAA batteries. IEC :LR03; Others : AAA, E92, 4003; JIS : AM 4 ; ANSI :24A; 1.5 Volt (nominal)

Remote Identifier: No battery required

Dimensions

MICROMAPPER: 4.92" x 2.05" x 1.54" 1125 mm x 52 mm x 39 mm

Remote Identifier: 1.87" x 1.12" x 0.87"47mm x 28mm x 22mm

Weight

MICROMAPPER with Remote Identifier: 125 g

Page 86: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

10

MicroMapperUsers Manual

Page 87: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroScanner™ ProThe essential cable verification tester

The MicroScanner™ Pro is a powerful verification tool designed to confirm basic

installation quality of multiple cable types. It automates the testing of cable conductor

continuity and configuration, and provides necessary information to rapidly solve prob-

lems including the location of cable faults. MicroScanner Pro tests coaxial cable (RG6,

RG59, etc., for CATV/CCTV), twisted pair cable (UTP/STP/SSTP), and other wiring for

audio, control, security or basic telephone service. The MicroScanner Pro speeds basic

live network testing with powerful network tap service and speed identification.

Quickly identify problemsUse the MicroScanner Pro for verification to ensure basic continuity and correct

terminations. The wiremap test checks end-to-end continuity on all UTP cable

four-wire pairs to quickly verify if the cable under

test has the correct wiring scheme (either 568A

or 568B) and identifies any cabling problems.

MicroScanner Pro quickly identifies a fault (see

Figure 1), allowing you to see opens, shorts,

crossed pairs, split pairs or any miswires.

Verify theQuality of YourInstallationVerification is the minimum indicator

of installation quality for many cabling

types, and plays an important role in

the success of any Voice, Datacom, or

Video (VDV) cabling installation.

Whether you’re performing new cabling

installations or working with existing

cabling infrastructure for moves,

additions, or configuration changes,

you can quickly verify your work with

an affordable test tool and have

confidence in a quality installation.

What is verification testing?

Verification testing confirms that a

cable meets established national or

international standards of conductor

configuration and passes basic

continuity testing. Verification may

be performed on two conductors or

multi-conductor twisted pair cabling.

Look to Fluke Networks’ MicroScanner

Pro and MicroMapper to perform

basic verification testing, as well as

troubleshoot and solve wiring mistakes

before they become real problems.

Both award-winning products are

backed by the superior support you’ve

come to expect from Fluke Networks,

the leader in network testing.

See how to ensure cable configuration quality with Fluke Networks verification tools

Figure 1. Pairs 1-2 are shorted.

Fluke Networks Microscanner Pro SpecsProvided by www.AAATesters.com

Page 88: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

to attach to the far end of the link (at the

workstation/office) and the MicroScanner

Pro will display the office number on the

display (see Figure 5).

Troubleshooting tools save you timeWhat happens when a fault is detected?

You waste valuable time with visual

inspection or troubleshooting by process

of elimination. With the push of a button,

MicroScanner Pro’s length function uses

Time Domain Reflectometry (TDR). TDR

acts like “cable radar” to measure the

distance to an open or short in each

conductor pair, or the overall length of

the cable. TDR provides the critical infor-

mation necessary to determine whether

to repair punched down conductors at the

block, replace a port or connector, or pull

a new cable. Overall cable length meas-

urement is useful for tracking cable usage

for billing and inventory purposes.

TDR even identifies the distance to active

network taps such as hubs or nic cards.

Identify active network connectionsMicroScanner Pro’s active network identifi-

cation mode flashes hub ports and shows

you if a network tap is operating at 10

Mbps or 10/100 Mbps and whether it is

full or half duplex capable. It also identi-

fies workstation network interface cards.

Tracing and locating cablesMicroScanner Pro’s toner function allows

you to generate a 1000 Hz tone detectable

by standard analog probes to trace and

locate hidden cabling in walls, ceilings or

distribution boxes. Four unique selectable

tones help identify different users toning

at the same time.

Identify cabling links from thewiring closetMicroScanner Pro Office/Room Identifier

allows you to identify cabling drops for an

office or room during adds, moves and

changes, and it helps determine routing at

the patch panel and documents twisted

pair and coaxial cabling installations. Use

the Office Identifier Plugs (shown below)

Coax Adapter (MT-8203-15)

Wiremap Adapter (MT-8203-14)

Office Identifier Plugs(MT-8203-17)

Bare-wire Adapter (MT-8203-16)

Figure 4. 10 Base-T signal detected, wired to PC.

Figure 5. Office/Room #4 termination ID.

MicroScanner Pro Accessories

Carrying Case (MT-8202-04)

Figure 3. Active network hub detected at 90 ft.

Figure 2. Showing 1-2 pair length.

MicroScanner Pro features• Tests all common copper cable types:

bare wire, coaxial cabling, UTP and STP

cabling

• Checks wire configuration (wiremap) to

ANSI/TIA/EIA 568A, 568B standards

• Speeds identification and troubleshooting

of common miswires such as opens,

shorts, crossed and split pairs

• Uses patented TDR technology to ensure

accurate pair length measurements

• Flashes hub light to help identify pairs

• Generates four unique tones for locating

cables hidden in walls, ceilings, or wiring

closets

• Identifies active networking 10 Base-T/

100Base-T hubs

• Identifies half or full duplex capability

• Matches (UTP or coaxial) cables to offices

during adds, moves and changes

• Enables patch cable testing without

couplers or external adapters

• Comes with one-year warranty

Page 89: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

MicroMapper™

The fast, comprehensive LAN wiremap checker

The MicroMapper is a small, handheld cable tester that enables network professionals

to verify the integrity of Ethernet twisted-pair cabling in one quick step. The

MicroMapper quickly and easily tests twisted-pair cabling, allowing you to see opens,

shorts, crossed, reversed and split pairs. Simply push the TEST button, and the

MicroMapper will automatically scan all wire pairs for any existing faults in your cable.

The MicroMapper also includes a remote unit to easily enable one-person testing of

installed cabling or patch cords. The MicroMapper includes a built-in tone generator

that allows you to trace cable through walls, floors, and ceilings when used with

IntelliTone Probe, or any other analog probe.

Features• Verifies UTP/STP network cable to

ANSI/TIA/EIA 568A and 568B

• Tests twisted-pair cables for open

circuits, shorts, crossed pairs,

reversed pairs and split pairs

• Easy-to-read LED fault display

• Tone generator works with IntelliTone

Probe or any other analog probes

• Conducts shield integrity testing

• Features self-storing remote unit to

allow one-person testing of installed

cables

• Includes extended battery life with

automatic sleep mode

• Low-battery LED

• Comes with one-year warranty

Page 90: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke Networks delivers Network SuperVisionFluke Networks offers the most compre-

hensive line of premises network testing

tools for the inspection, verification,

certification, and documentation of

copper and fiber optic cabling systems.

Network owners, installers and maintain-

ers alike choose our products because

they provide superior vision into their

networks. From products that stay ahead

of your technology needs, to responsive

service to keep you up and running, Fluke

Networks has everything you need to keep

pace in today’s fast moving networked

world.

Specifications

Ordering Information

Product Specs

MicroScanner Pro Dimensions: 5.5” x 3.25” x 1” (139.7 x 82.5 x 25.4 mm)Battery: 9-volt alkaline battery; low battery indicationDisplay: custom LCD, 1.75” x .85” (44.45 x 21.59 mm)Applications: shielded (STP) and UTP cable; 75 or 50 Ohm Coaxial cable; 10 Base-T or 10/100 Base-T networksMain tester interface: modular 8 connector for length, 10/100 link identification, wire map, office identifier, toner; loopback interface: module 8 connector used for patch cable wiremapLength measurement: measures length on all 4 pairs and displays in feetor meters; ±4% or ±2 ft whichever is greater, max length 1500 ft (457 m)Length calibration: user selectable NVP, NVP calculation based on knowncable length (min. length 50 ft (15 m) and max. length 1500 ft (457 m)Wiremap and Office/Identifier: faults detected: opens, shorts, reversedpairs, swapped pairs, and split pairs, distance maximum length: 656 ft(200M)Office Identifier: 6 passive test plugs attached to far end (identified as #1-3 and #5-7); distance maximum length 656 ft (200 mm)Toner frequency: user may select 1 of 4 predefined tone sequencesToner Interface: main Mod8 port for tone generation on all 4 pairs. Ground jack provided for grounding MicroScanner Pro during trace operations.High voltage input/protection: the test interface withstands input hazardconditions that arise from normal telephone interfaces (48 VDC at less than 80 mA) or 24 VAC power used to power many telephone keysets.

Wiremap Adapter Dimensions: 2.25” x .5” x .625” (57.15 x 12.7 x 15.875 mm)Coax Adapter Dimensions: 3” x .63” x .58” (76.2 x 16 x 14.7 mm)MicroMapper Dimensions: 4.93” x 2.05” x 1.18” (125 x 52 x 30 mm)

Weight: 0.28 lbs (130 g)Minimum length for split pair detection: 2 ft (0.6 m)Maximum Testing length for twisted pair cables: 656 ft (200 m)Battery: (4) 1.5-volt AAA alkaline batteries; low battery indication by LED

Model Number Items Included

MT-8200-32A MicroScanner Pro Includes: MicroScanner Pro, Wiremap Adapter (Office ID 4), Coax Adapter (CATV type, F-connector), 9-volt Alkaline battery, Quick Reference Guide, andUser CD

MT-8200-24A MicroScanner Pro VDV KitIncludes: MicroScanner Pro, IntelliTone Probe, wiremap adapter, coax adapter(CATV type, F-connector), office/room ID kit, 9-volt alkaline battery, QuickReference Guide, and User CDMicroScanner Pro Accessories

MT-8202-04 MicroScanner Pro Carrying CaseMT-8203-15 Coax Adapter Replacement Part (RJ45 to F Connector)MT-8203-17 Office/Room ID Kit (IDs 1 – 3, 5 – 7)MT-8203-14 Wiremap Adapter Replacement Part (Office ID 4)MT-8203-16 Bare Wire Adapter (with alligator clips)

MT-8200-49A MicroMapperIncludes: MicroMapper and MicroMapper Remote, RJ45 patch cable, (4) 1.5 Volt AAA alkaline batteries, Quick Reference Guide, and User CD

Fluke NetworksP.O. Box 777, Everett, WA USA 98206-0777

Fluke Networks operates in more than 50 countriesworldwide. To find your local office contact details, goto www.flukenetworks.com/contact.

©2004 Fluke Corporation. All rights reserved. Printed in U.S.A. 1/2004 2113135 D-ENG-N Rev A

N E T W O R K S U P E R V I S I O N

Page 91: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Datasheet: IntelliTone™ Pro 200 LAN Toner and Probe SeriesDatasheet: IntelliTone™ Pro 200 LAN Toner and Probe Series

Breakthrough digital and analog toning in oneIntelliTone Pro is the first toner and probe to offer digital and analog toning all in onetool. That means it’s equipped with the most powerful cable location and verificationtechnologies for any work environment – even active networks.

Eliminates confusion over cable location; decisively rejects noise and falsesignalsLocates the correct cable bundleIsolates a cable within the bundle, despite cable bleedVerifies twisted-pair installation with visual end-to-end continuity test (opens,shorts and reversed pairs)Identifies individual wire pairs with new SmartTone™ analog toningSimplifies signal interpretation in noisy environments with multiple LED indicators

Locate cables quickly and easilyFluke Networks has applied decades of cable test engineering expertise to thescience of locating copper cables. The result is what we call IntelliTone technology –a digital signal-toning and signal-interpreting process that rapidly zeroes in on cables.

IntelliTone technology energizes cable conductors with a smart, sychronized digitalsignal. Multiple tone types occur in the signal that help you to:

LOCATE the correct cable bundle using maximum radiation.ISOLATE a cable within the bundle using a signal with minimum radiation.VERIFY cable conductor continuity with an automated signal that steps througheach conductor.

Every day, cabling installers andnetwork technicians deal with theshortcomings of cable location toolsbased on 40-year-old technology.Until now.

The IntelliTone™ Pro 200 LANToner and Probe Series from FlukeNetworks gives you cutting-edgedigital and analog cable locatingtechnologies that are as advancedas the systems you work with.IntelliTone is a breakthroughsolution – and the only solution –that locates and isolates the mostelusive, hidden or bundled voice,data and video cables and wire pairsquickly and reliably – even on activenetworks.

1 of 5

Page 92: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Locate hidden cablesOne of the toughest, most time-consuming parts of locating a cable has been intracing its path amidst multiple cables and bundles in wiring closets. The IntelliTonedigital signal features a LOCATE tone that provides maximum radiation, allowing youto quickly locate hidden and hard-to-find cabling.

Isolate the right cable or pair – fastCabling installations have become increasingly complex, which has made cablingincreasingly difficult to locate with traditional technologies.

When cables are run together for even short lengths, a signal from one can bleedover to another. One cable might carry the original signal; other cables might carry thesignal as a result of bleed. Isolating cables with traditional tools requires guesswork,training, time for repeated testing – and even the best efforts often result in mistakes.

IntelliTone Pro provides two cutting-edge technologies to isolate cables or wire pairs.Digital mode can be used to isolate twisted-pair cables on a switch or within a bundle.SmartTone™ analog mode can be used to isolate wire pairs at an unterminatedoutlet.

Overcome noise – and save hours of timeFluorescent lights, machinery, computer monitors and electrical wiring all producenoise that slows down cable location. Together, the IntelliTone Pro Toner’ssynchronized digital signal and the IntelliTone Pro Probe’s microprocessor controlledsignal identification technology reject noise and false signals to clearly identify cablelocation. This can save you hours every week on cable location projects.

Tone on live networks safely and effectivelyModern network devices use common mode termination for cables connected to their ports. This reduces noise and crosstalk in thecable; but, it can also absorb a traditional toner signal. Unlike traditional signals, the IntelliTone digital signal stays strong despitecommon mode termination. And the IntelliTone Pro 200 LAN Toner automates toning individual cable conductors, making it quick,efficient and safe to locate cables on active networks

Tone on live networks safely and effectivelyModern network devices use common mode termination for cables connected to their ports. This reduces noise and crosstalk in thecable; but, it can also absorb a traditional toner signal. Unlike traditional signals, the IntelliTone digital signal stays strong despitecommon mode termination. And the IntelliTone Pro 200 LAN Toner automates toning individual cable conductors, making it quick,efficient and safe to locate cables on active networks.

Verify conductor continuity with cablemapEliminate callbacks during cabling moves, adds and changes with the powerful diagnostic capabilities of IntelliTone™ Pro 200 LAN.The IntelliTone Pro 200 Probe features a Cablemap capability that identifies common cable miswires in twisted pair cabling.IntelliTone technology automates the testing of each conductor for end-to-end continuity; LED lights and tones clearly indicatemiswires.

2 of 5

Page 93: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Identify and troubleshoot cable servicesService – Is the RJ45 jack a datacom jack, or a dead jack? IntelliTone Pro 200 LAN Toner LEDs clearly identify common datacomservices found on today's networks including 10/100/Gigabit Ethernet links.

Continuity – Once you’ve located a cable, the next step is to verify cable conductor continuity. IntelliTone Pro 200 LAN Tonersmake it easy – eliminating the need for a separate diagnostic tool.

200 LAN Toner

1. IntelliTone provides robust toning into active network equipment whileeliminating cable misidentification due to bleed

2. Banana jacks allow you to use only the leads you need and facilitates easyreplacement

3. Test cable continuity, eliminating need for separate diagnostic tool4. Test cable continuity, eliminating need for separate diagnostic tool5. Precisely isolate wire pairs with built-in SmartTone analog toning6. Tone active networks safely and effectively with IntelliTone digital mode7. Identify resistance and if digital tone or analog tone function is operational8. Identify and diagnose Ethernet link connectivity with NIC/hub indication9. Cable termination indicator identifies if cable is connected or not

10. Knob provides simple, task oriented operation

200 Probe

1. Multiple-level LEDs simplify signal interpretation in noisy environments. Visually steps through wiremap tests2. SYNC indicates detection of IntellTone signal and shows battery status at power-up

Choose between two digital detection modes:

3. Digital detection mode: lets you locate cables at a distance4. Digital detection mode: lets you isolate cables in bundles or at patch panels5. Analog mode used to isolate individual wire pairs with SmartTone6. Test cable continuity – eliminating need for separate diagnostic tool7. Time-saving thumbwheel lets you select desired toning mode on the probe rather than toner8. Plug works with CableMap function – eliminating the need for a separate wiremap tool

3 of 5

Page 94: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Toner and Probe shared features:IntelliTone digital technology with advanced signal processing provides high-resolution measurement

Auto-Off feature: The toner turns off automatically after 2.5 hours of inactivity. Probe turns off after 1 hour of inactivity

SmartTone™ analog technology: IntelliTone Pro Toners generate four different analog songs which alternate every time the pairunder test is shorted; IntelliTone Pro Probes detect this tone or any other analog signal from other testers

Battery status: 3-level battery status indicator LEDs on the toner and probe light for one second at power on

Specifications

General

Operating temperature 32° F to 104° F (0° C to 40° C)

Storage temperature -4° F to +140° F (-20° C to +60° C)

Operating relative humidity(% RH without condensation)

95% (50° F to 95° F; 10° C to 35° C)75% (95° F to 104° F; 35° C to 40° C)Uncontrolled < 50° F (< 10° C)

Vibration Random, 2 g, 5 Hz – 500 Hz

Shock 1 m drop test with and without module

Safety IEC 61010 Category: None

Altitude 3000 m

EMC EN 61326-1

Battery type and life 9 V alkaline (NEDA 1604A or IEC 6LR61); 20 hours typical

Applications Copper cabling media, including shielded (STP) and UTP cable; 75 or 50 Ohm coaxial cable; two conductorcontrol, security, generic cabling. 10 Base-T or 10/100/1000 Base-T datacom networks.

Toner

Dimensions 5.54 in x 2.94 in x 1.25 in (14.1 cm x 7.5 cm x 3.2 cm)

Display LED

Control Thumbwheel switch

Toner interface Main Mod8 port for tone generation on all 4 pairs of UTP / STP cabling, F connector for coaxial cabling, Banana jack plugs(2) – two conductor wiring

Toner frequency IntelliTone signal: encoded digital signal Analog SmartTone signal: 500-1200Hz, 4 Songs

Output power 5 V p-p

Auto power down Turns off automatically after 2.5 hours of inactivity

4 of 5

Page 95: Fluke BP120MH NiMH Battery Pack for Fluke 120 series ... (p… · PM8907 power adapter/charger. The BP120MH replaces the earlier models BP120 and BP130 alike. Specs: Nominal voltage

Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact.

© 2017 Fluke Corporation. Rev: 04/03/2017 1:35 am (Literature Id: 2113101B)

Probe

Dimensions 8.73 in x 1.88 in x 1.26 in (22.2 cm x 4.8 cm x 3.2 cm)

Display (8) LED indicators, Synch LED indicator

Audio IntelliTone: Microprocessor controlled audio files, Analog: Detected toner signal

Control Thumbwheel switch, volume control wheel

Tone detection Detects IntelliTone digital signal for Locate, Isolate and CableMap Detects Analog SmartTone Signal (500-1200Hz) andother analog toners.

Toner interface Main Mod8 port for cablemap on all four pairs of UTP / STP cabling

Auto power down Main Mod8 port for cablemap on all four pairs of UTP / STP cabling

Ordering Information

Model Number Items Included

MT-8200-60-KITIntelliTone Pro 200 LAN KitIncludes IntelliTone Pro 200 LAN Toner and 200 Probe, coax F connector adapter, two RJ11 and two RJ45 patch cables,test leads with alligatorclips, lanyards, quick start guide, and two 9 volt batteries

MT-8200-61-TNR IntelliTone Pro 200 LAN Toner

MT-8200-63A IntelliTone Pro 200 Probe

IntelliTone Pro Toner and Probe Accessories

MT-8202-05 IntelliTone Pro Case

MT-8203-20 Test Leads with Bed of Nails

MT-8203-22 Test Leads with Alligator Clips

IntelliTone Pro 200 LAN Kit

Finds the cables the others can'tIntelliTone digital signal processing rejects noise and false signalsSmartTone analog signal precisely isolates individual wire pairsTones safely and clearly on active networksTests for continuityIdentifies and diagnoses 10/100/1 Gb Ethernet link connectivity with NIC/hub indicationVerifies twisted-pair installation with CableMap capability which identifies common cable miswire

5 of 5