Page 1: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

1

MWEA Collection System Seminar September 11, 2014

FLOW METER OPERATION & MAINTENANCE

1

Page 2: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

2

Operations & Maintenance

• Permanent Meters

• Billing meters

• Meters used for Temporary Studies

2

Page 3: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

3

Area - Velocity Flow Meter

• Continuity Equation Q = A x V

• Q = the volumetric flow rate

• A = the cross sectional area of the flow

• V = the mean velocity

3

Page 4: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Area Velocity Flow Meters

Page 5: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Area Velocity (Continuous Wave Doppler)

Flow Meters

Advantages

• Easy installation & maintenance.

• Can measure flows down to 1 inch of level.

• No enclosure required.

• Relatively low cost.

Disadvantages

• Accuracy of +5% in normal field conditions.

• Maintenance required (Sensor subject to fouling and grease).

Page 6: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

6

Doppler - Area Velocity Meter Probe

Page 7: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

7

7

Page 8: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

8

Pressure - Depth sensor

8

Page 9: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

9

Doppler - Area Velocity Meter Probe

Page 10: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

10

Atmospheric Pressure

10

Page 11: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

11

Pressure Sensors

• Atmospheric vent tube

11

Page 12: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

12

DESICCANT - ATMOSPHERIC REFERENCE

• Blue is good!!

12

Page 13: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

13

DESICCANT

13

Page 14: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

14

It’s time to replace the desiccant

14

Page 15: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

15

Pressure Sensors are expensive

15

Page 16: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

16

Pressure - Depth sensor

16

Page 17: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

17

Communicate with Maintenance staff

17

Page 18: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

18

Site Selection - ?

18

Page 19: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

19

Range Gated Doppler Flow Meter

19

Page 20: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

20

ADFM

• Ultrasonic level sensor

20

Page 21: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

21

ADFM Velocity Profile

21

Page 22: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

22

Full Pipe Flow Meter (ADFM)

22

Page 23: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

23

ADFM Flow Meter

• AC or DC powered

23

Page 24: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

24

Radar Flow Meter

24

Page 25: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

25

Radar Flow Meter

25

Page 26: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

26

Radar Flow Meter

26

Page 27: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

27

Radar Flow Meter

27

Page 28: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Radar Flow Meters

Advantages • Non-contact level and

velocity sensors.

• Will work in large & small pipes.

• Easy installation & maintenance.

• No enclosure required.

• Relatively low cost.

Disadvantages • Accuracy of +5-% in

normal field conditions.

• Surface velocity only.

• Requires trained technician for repair and calibration.

Page 29: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

29

LASER - FLOW METER

29

Page 30: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

30

LASER FLOW METER

• No contact with the flow

30

Page 31: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

31

LASER FLOW METER

• Multiple velocity reads

31

Page 32: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

32

LASER FLOW METER

• No contact with the flow

32

Page 33: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Laser Flow Meters

Advantages • Non-contact level and

velocity sensors.

• Multipoint profile, (15 -measurements 5 horizontal and 3 vertical

• Depth measurements (5%, 8% and 11% of depth)

• No enclosure required.

• Relatively low cost.

Disadvantages • Accuracy of +5-% in

normal field conditions.

• Maximum depth penetration is 6”

• Therefore the meter is seeing peak velocity and is unable to see the full profile of the flow

• Requires trained technician for repair and calibration.

Page 34: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

34

Magnetic Flow Meter

34

Page 35: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

35

Magnetic Field

35

Page 36: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

36

Magnetic Flow Meter Probe

36

Page 37: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

37

Magnetic Flow Meter Probe

37

Page 38: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

38

Battery Powered Meters

• You get what you pay for

38

Page 39: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

39

TRANSIT-TIME FLOW METER

• Multi-Path Meter

39

Page 40: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

40

Transit-Time Flow Meter

40

Page 41: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

41

Transit-Time Flow Meter

41

Page 42: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Transit Time Flow Meters

Page 43: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Transit-Time Flow Meters

Advantages • High degree of accuracy

(+2 to 5%) – Open Channel. (+0.5%) Full pipe application.

• Good for large pipes.

• Wide flow range.

• Ability to handle poor hydraulics.

Disadvantages • Relatively high cost.

• Air entrainment can cause issues.

• Requires a skilled technician and specialized equipment.

• Above ground enclosure required.

Page 44: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Transit Time Flow Meters

Page 45: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

45

45

Page 46: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

46

• Cable Repair

– Don’t step on the cables. You can nick the cable jacket and this may allow moisture to cause short circuits.

– Most cables can not be repaired.

– If the cable or probe are damaged, it is very costly to replace.

46

Page 47: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

47

Magnetic (MAG) Flow Meter

47

Page 48: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Magnetic Flow Meters

Page 49: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Magnetic Flow Meters

Advantages • High degree of accuracy

(+0.5%) and consistent over full flow range when calibrated properly.

• No obstructions to flow.

• No moving parts.

• Wide flow range.

• Fixed area measurement

Disadvantages • Requires a FULL pipe

• Relatively high construction cost.

• Power supply is required.

• Repairs require skilled technician and specialized equipment.

• Electronic components vulnerable to lightning damage.

Page 50: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

50

Verify Your Information

50

Page 51: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

51

Pull out the maintenance file and check the settings

51

Page 52: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

52

Check all of the settings

52

Page 53: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

53

Parshall Flumes

53

Page 54: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

54

54

Page 55: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

55

Ultrasonic Down Looker

55

Page 56: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Parshall Flumes

Advantages • High degree of accuracy

(+2%) and consistent over full flow range when calibrated properly.

• No moving parts.

• Wide flow range.

• Sediment control.

Disadvantages • Relatively high

construction cost.

• Level measurement required.

• Possible construction flaws.

Page 57: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Parshall Flumes

Page 58: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Parshall Flume with Foam

Page 59: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Parshall Flume with Solids

Page 60: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

60

The Data Looks Good ???

60

Page 61: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

61

61

Page 62: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

62

Verify the As-Built Information

62

Page 63: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

63

Velocity Profiling

• .

63

Page 64: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

64

Portable Velocity Meter

• Send it back to the factory once per year to be re-certified

64

Page 65: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

65

Velocity Profile

65

Page 66: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

66

66

Page 67: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

Why isn't there any velocity reads?

Page 68: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

68

Flow Lab Verification

68

Page 69: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

69

Flow Lab Verification

69

Page 70: FLOW METER OPERATION & MAINTENANCE - … - Flow Meter.pdf3 Area - Velocity Flow Meter •Continuity Equation Q = A x V •Q = the volumetric flow rate •A = the cross sectional area

John MacDonald Martin Control Services [email protected]

800 300 1966

Any Questions?