floor standing 75 -200 - daikindaikinapplied.co.id/.../uploads/2018/01/floor-standing-75-200.pdf ·...
TRANSCRIPT
MFS-15
Easy and Flexible Installa�onThe easy is highly compact and therefore it is very easy to selecta loca�on to install the unit such that only small space isrequired.
Maximum Allowable Piping Length & Eleva�on Difference
Easy MaintenanceThe simple design concept hasmaintenance and servicing in mind.Access to the internal parts of the unitcan be from front or back of the unit byremoving a few screws
Filter RackThe fan coil unit has a filter rack to holdthe air filter. This ensure the air flow isclean and the filter is easily accessiblefor maintenance and cleaning
CasingThe unit is made of 0.8 to 2.3 mm galvanized steel body withpolyester powder coat. It is insulated with 10 mm polyethylenefoam. A perforated sheet cover protects the filter from damage.
Electric ControllerElectric Controller can display cool, dry and fan mode with auto, high, medium and low fan speed. The temperature se�ngs range from 16 OC and 30 OC. There is a sleep func�on for coolmode and programmable on / off �mer 1 hour interval. The controller is built with 3 minutes restart delay �mer for compressor protec�on.
Netware 3SLM 3
Another Quality Product bywww.daikinapplied.co.id
Head Office:
Surabaya. Jl. Kayoon 42-44, Surabaya 60271, Indonesia | P. +62-31-547 8787, 532 5365 | F. +62-31-532 0049Bali. Pertokoan Gunung Soputan Blok B, Jl. Gunung Soputan No. 11, Denpasar 80117, Indonesia
P. +62-361-485 854, 746 9449 | F. +62-361-485 854
Balikpapan. Sentra Eropa II AB - 5 No. 1 Balikpapan Baru, Kalimantan Timur, Indonesia
P. +62-542-720 4205, 721 2085 | F. +62-542-721 2087
Timika. Jl. Cendrawasih Jalur SP 2, Timika, Papua 99910, Indonesia | P. +62-901-323 817 | F. +62-901-323 817 Jakarta. Jl. Pancoran Barat VII, Duren Tiga, Jakarta 12760, Indonesia | P. +62-21-7919 2468 | F. +62-21-7919 2473
Medan. Jl. Pinang Baris No. 28, Komp. Imperium, Kel. Sunggal, Medan 20128, Sumatera Utara, Indonesia
P. +62-61-8002 5528, 8002 5828 | F. +62-61-8002 5628
Branch Office:Jakarta. Wisma Keiai Building 19th Floor, Jl. Jenderal Sudirman Kavling 3 Jakarta 10220 – Indonesia P : +62 21 572 3322 (hunting) | F: +62 21 572 3323
M F S 75
A
Genera�on
Capacity 75, 100, 125, 150
Standing Fan Coil
Floor
Mc Quay
NOMENCLATURE
24 HOUR
Feature & Excellence R407C• Designed to substitute R22
• Physical and thermodynamic properties comparable to R22
• Zeotropic refrigerant blend containing R32, R125 & R134a (23/25/52% by weight)
• Temperature glide approximately 7K ( zeotropicbehavior)
23 % R32 25 % R125
( R407C )
52 % R134A
• Miscible with polyoester oils (POE)
• Environmentally acceptable (ODP = 0)
• Able to retrofit existing R22 units
• Non-flammable and safe to use
• Commercially available
( optional )
R407C
FREE BLOW SPLIT AIR CONDITIONER
75-200
INDOOR UNIT MFS 75A MFS 100A MFS 125A MFS 150A MFS 200 A2 MODEL
OUTDOOR UNIT M4MC 75B M4MC 100B M4MC 125B M4MC 150C M4MC 100 B x 2
NOMINAL COOLING CAPACITY Btu/h 75,000 100,000 125,000 150,000 200,000
REFRIGERANT R407C
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 380-415 / 3 / 50
TYPE CENTRIFUGAL / DIRECT DRIVEN BELT DRIVE
QUANTITY 1 2 2 2 1 ( Twin Blower)
NOMINAL AIR FLOW CFM 2,000 3,000 3,500 4,000 5,800
OUTLET VELOCITY m/s 9.41 8.60 10.00 11.40 9.4
MOTOR OUTPUT W 500 375 x 2 500 x 2 500 x 2 1,500
CAPACITOR SIZE Mf 16 7.5 16 16
RATED RUNNING CURRENT (EACH) A 3.7 1.7 3.25 3.7 3.4
FAN MOTOR POLES 4 6 4 4 4
BLO
WER
&M
OT
OR
EXTERNAL STATIC PRESSURE inWG 0.4 0.4 0.4 0.4 0.6
MATERIAL COPPER
DIAMETER mm 9.52
TU
BE
THICKNESS mm 0.3
MATERIAL ALUMINIUM
THICKNESS mm/in 0.11
ROWS 4 3 3 4 FIN
FIN PER INCH 12 12 12 12
FACE AREA ft2 5 9 9.5 9.5 12.95
AIR VELOCITY FPM 380 317 360 399
CO
IL
AIR PRESSURE DROP inWG 0.35 0.2 0.25 0.38
MATERIAL ELECTRO GALVANISHED MILD STEEL CASING
FINISH EPOXY POLYSTER POWDER COATING
HEIGHT mm 1,800 1,900 1,900 1,900 1,920
WIDTH mm 530 530 530 530 1,420 DIMENSION
DEPTH mm 700 1,050 1,050 1,050 700
WEIGHT kg 110 160 165 170
CONTROL ROOM TEMPERATURE THERMOSTAT ELECTRONIC CONTROL
THERMAL EXPANSION VALVE
GAS in 1 1-1/8 1-3/8 1-3/8 1-1/8 PIPING CONNECTION LIQUID in 1/2 5/8 5/8 5/8 5/8
CONDENSATE DRAIN SIZE STEEL PIPE 1"
STEEL PIPE 1 ( MALE THREADED )
TYPE 70% EFICIENCY WASHABLE FILTER SARANET
SIZE WIDTH x HEIGHT mm 545 x 908 450 x 963 587 x 716
THICKNESS mm 12 6 FILT
ER
QUANTITY 1 2
HEIGHT mm/in 2,000 2,050 2,060
WIDTH mm/in 680 680 1,666
IND
OO
R
PACKING DIMENSION
DEPTH mm/in 955 1,305 850
TYPE SCROLL
POWER SOURCE V/Ph/Hz 415 / 3 /50 380-415 / 3 / 50
RATED RUNNING CURRENT A 13.6 16.9 17.9 23.5 15.9
LOCKED ROTOR AMPS A 95 125 110 198
RATED INPUT POWER W 6,810 9,040 10,200 13,300 8,540
PROTECTION DEVICE OVERLOAD PROTECTION AND AUTO RESET HIGH/LOW PRESSURE SWITCH
CO
MP
LUBRICANT EMKARATE RL 32-3MAF
FAN TYPE / DRIVE PROPELLER / DIRECT
BLADE MATERIAL ALUMINIUM
DIAMETER mm/in 660.4 / 26.0 762.0 / 30.0 660.4 / 26.0
POWER SOURCE V/Ph/Hz 415 /3 /50 415 / 3 / 50 380-415/3/50
RATED RUNNING CURRENT A 1.40 1.50 1.43 4.35 1.5
FAN
RATED INPUT POWER W 680 660 640 3,200 466
MATERIAL COPPER
DIAMETER mm/in 9.52 (3/8)
TU
BE
THICKNESS mm 0.3
MATERIAL ALUMINIUM
THICKNESS mm 0.11
NUMBER x ROWS 2 x 1 12 2 x 2 2 x 2 FIN
FIN PER INCH 14 19 16 14 12
CO
IL
FACE AREA ft2 19.00 13.38 19.00
HEIGHT mm 946 1,041 946
WIDTH mm 1,116 DIMENSION
DEPTH mm 939
WEIGHT kg 162 193 224 193
MATERIAL ELECTRO-GALVANISED MILD STEEL CASING
FINISH EPOXY POLYSTER POWDER COATING
SOUND PRESSURE LEVEL dBA 70 72 75 77 72
REFRIGERANT Type R407C
GAS in 1 1-1/8 1-3/8 1-3/8 1-1/8
OU
TD
OO
R
PIPING CONNECTION LIQUID in 1/2 5/8
Cooling Only, R407C
OUTDOOR UNIT MODEL: MMC 75B, 100/125B (STANDARD VERTICAL AIR DISCHARGE)
MODEL: MMC 150C (STANDARD VERTICAL AIR DISCHARGE – NON CONVERTIBLE)
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).
5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION
6
INDOOR UNIT MODEL: MFS 75A
MODEL: MFS 100A/125A/150A
MODEL DIMENSION
Liquid Suc?on
100 5/8 " 1-1/8 "
125 5/8 " 1 - 3/8 "
150 5/8 " 1- 3/8 "
SIDE VIEW FRONT VIEW SIDE VIEW BACK VIEW
TOP VIEW
R
SIDE VIEW FRONT VIEW SIDE VIEW BACK VIEW
TOP VIEW
R