54 UVRaman-100 DSR 100 GaiaField GaiaSorter Chameleon Spectrographs SGM 100 Light Source Detector E-MAIL: [email protected] TEL: +86 10 56370168 http://www.zolix.com.cn Sample Chambers SAC is a three-port sample champer, which can be easily configured for transmittance, reflectance, absorbance, fluorescence or Raman measurements. All quartz lenses for excellent transmission in the spectral range 185 nm to 2.5 μm. Each quartz lens unit can be individually adjusted to provide either a collimated or focused beam depending upon the sample and application requirements. The sample holder comprises of an XY and rotation stage which allows critical alignment and rotation of the sample to be performed in order to optimise the recorded signal. XY translation of 10 mm in both axes and rotation of 360°is possible. The SAC is compatible with the range of Omni-λ monochromators and spectrographs. SPECIFICATIONS SAC UNIT Wavelength Range 185-2500 Amount Of The Light Exit 3 Amount Of Lens 3 Adjusting Range of the Height 213-243 Length 330 Width 280 Weigh 10 SAC

Upload: others

Post on 06-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FLG series Fiber Bundle SAC FLG series Fiber Bundle · 5:1 B B 5:1 A B X 3 13 83 1 0-0. 0 8-. 5 0 1 9 + 0. 0 9 X A B Fibers order of Fiber bundle port A Fibers order of Fiber bundle

54

UVRaman-100 DSR 100 GaiaField GaiaSorter Chameleon Spectrographs SGM 100 Light Source Detector

E-MAIL: [email protected] TEL: +86 10 56370168 http://www.zolix.com.cn

Sample Chambers

SAC is a three-port sample champer, which can be easily configured for transmittance, reflectance, absorbance, fluorescence or Raman measurements.

All quartz lenses for excellent transmission in the spectral range 185 nm to 2.5 μm.Each quartz lens unit can be individually adjusted to provide either a collimated or focused beam depending upon the sample and application requirements.

The sample holder comprises of an XY and rotation stage which allows critical alignment and rotation of the sample to be performed in order to optimise the recorded signal. XY translation of 10 mm in both axes and rotation of 360°is possible.

The SAC is compatible with the range of Omni-λ monochromators and spectrographs.

SPECIFICATIONS

SAC UNIT

Wavelength Range 185-2500

Amount Of The Light Exit 3

Amount Of Lens 3

Adjusting Range of the Height 213-243

Length 330

Width 280

Weigh 10

SAC FLG series Fiber Bundle

Tel 010 60535165 http www zolix com cn: ://- . . .

FLG series fiber bundle using with BFC Series fiber bundle connector which can work well

with ZOLIX Omni monochromators light souce sample chamber and so on

- , , .λ

ModelSpectral range

(nm)

Core Diameter

(μm)

Number of

FibersMaterial A port B port

FLG-106-x 380-800 600 1 Glass SMA905 SMA905

FLG-401-x 200-1100 200 19 Silica Φ13mm Cylinder SMA905

FLG-402-x 400-2400 200 19 Silica Φ13mm Cylinder SMA905

FLG-403-x 400-1800 200 19 Silica Φ13mm Cylinder SMA905

FLG-404-x 200-1100 200 19 Silica SMA905 SMA905

FLG-405-x 400-2400 200 19 Silica SMA905 SMA905

FLG-406-x 400-1800 200 19 Silica SMA905 SMA905

FLG-407-x 200-1100 200 19 Silica Φ10mm Cylinder SMA905

FLG-408-x 400-2400 200 19 Silica Φ10mm Cylinder SMA905

FLG-409-x 400-1800 200 19 Silica Φ10mm Cylinder SMA905

A

A

5 : 1

B B

5 : 1

BA

X

3

13

83

10

-0.0

8-0

.15

30+

0 .19

+0 .09

X

BA

Fibers order of Fiber bundle port A Fibers order of Fiber bundle port B

B

13

X 5

17

A

FLG-106/404/405/406-x Outline

FLG-401/402/403-x Outline

FLG-407/408/409-x Outline

106

SAC Sample ChambersSpectroscopy Components

SAC is a three-port sample chamber, which can be easily conÞgured for transmittance, reßectance, absorbance, ßuorescence or Raman measurements.

All quartz lenses for excellent transmission in the spectral range 185 nm to 2.5 μm

Each quartz lens unit can be individually adjusted to provide either a collimated or focused beam depending upon the sample and application requirements.

The sample holder comprises of an XY and rotation stage which allows critical alignment and rotation of the sample to be performed in order to optimise the recorded signal. XY translation of 10 mm in both axes and rotation of 360¼ is possible.

The SAC is compatible with the range of Omni-λ monochromators and spectrographs.

Each sample chamber has the far -UV silicon lens

SPECIFICATIONSSPECIFICATIONSSPECIFICATIONS

SAC UNIT

Wavelength Range 185 - 2500 nm

Amount Of The Light Exit 3 -

Amount Of Lens 3 -

Adjusting Range Of The Height 213 - 243 mm

Length 330 mm

Width 280 mm

Weigh 10 kg

Size 330 × 280 × 213 - 243 (W × D × H, H-adjustable) mm

www.gildenphotonics.com [email protected] T: +44-(0)141-952-9475

FLG series Fiber Bundle

Tel 010 60535165 http www zolix com cn: ://- . . .

FLG series fiber bundle using with BFC Series fiber bundle connector which can work well

with ZOLIX Omni monochromators light souce sample chamber and so on

- , , .λ

ModelSpectral range

(nm)

Core Diameter

(μm)

Number of

FibersMaterial A port B port

FLG-106-x 380-800 600 1 Glass SMA905 SMA905

FLG-401-x 200-1100 200 19 Silica Φ13mm Cylinder SMA905

FLG-402-x 400-2400 200 19 Silica Φ13mm Cylinder SMA905

FLG-403-x 400-1800 200 19 Silica Φ13mm Cylinder SMA905

FLG-404-x 200-1100 200 19 Silica SMA905 SMA905

FLG-405-x 400-2400 200 19 Silica SMA905 SMA905

FLG-406-x 400-1800 200 19 Silica SMA905 SMA905

FLG-407-x 200-1100 200 19 Silica Φ10mm Cylinder SMA905

FLG-408-x 400-2400 200 19 Silica Φ10mm Cylinder SMA905

FLG-409-x 400-1800 200 19 Silica Φ10mm Cylinder SMA905