FLFE...L, FLF...L series Lighting fixtures with LED strips
Lighting fixtures for LED strips FLFE-...L (Ex de) and FLF-...L (Ex d) series have two low copper content aluminium heads, a tempered borosilicate glass tube that is resistant to changes in heat and a white painted aluminium reflector. The ‘Ex de’ lighting fixture features an “Ex e” terminal board housing that allows entry to the lamp with a cable gland with an “Ex” seal (normal) as specified in installation standard (EN/IEC 60079.14). The entry to the ‘Ex d’ lighting fixtures must be through an Ex “barrier” cable gland (sealed) or, in the case of a conduit system, with an EYS, EZS series sealing fittings. The round cross section of the lamp provides a better “Cx” coefficient with less resistance to the wind and less accumulation of dust. For this reason, these units are recommended for use in hazardous places where climatic and environmental conditions are severe and as they require less maintenance thanks to a very high ageing index. As the electrical components are housed on a frame with guides, any maintenance is quick and efficient. The fact that the fixture is fitted with a glass tube as opposed to a plastic material, makes it more effective and with a longer lifespan.
Application sectors:
CERTIFICATION DATA
Classification: Group II Category 2GD
Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust)
Marking: II 2GD Ex db op is IIC T6 Gb - Ex tb op is IIIC T71÷T80°C Db IP66 (FLF)
II 2GD Ex db eb op is IIC T6 Gb - Ex tb op is IIIC T71÷T80°C Db IP66 (FLFE)
Certification: ATEX CESI 09 ATEX 008
IECEx CES 11.0021 All IEC Ex certification data can be downloaded at www.cortemgroup.com
Standards:
CENELEC EN 60079-0: 2012, EN 60079-1: 2014, EN 60079-7: 2007, EN 60079-31: 2014 and EUROPEAN DIRECTIVE 2014/34/UEIEC 60079-0:2004, IEC 60079-1:2007, IEC 60079-7:2006, IEC 61241-0:2004, IEC 61241-1:2004European Directive 2006/95 Low voltageEuropean Directive 2004/108 Electromagnetic compatibilityEuropean Directive 2003/108 WEEE Waste electrical and electronic equipmentEuropean Directive 2011/64 RoHS
Class temperature: 80°C (T6)
Ambient temperature:Normal operation or emergency with
separate batteries
-20°C +55°C
Emergency with batteries installed inside
-20°C +50°C
Degree of protection: IP66
Chemicaland petro-chemicalplants
Oil andcombustibleliquid depots
Oilrefineries
100%Cortemproduct
Farmproduce
applications
Offshoreplants
Stairhandrails
Onshoreplants
101 ED.2019
FLFE...L, FLF...L series Lighting fixtures with LED strips
MECHANICAL FEATURES
ORIGINAL PRODUCT
Different rated voltagesInstallation mounting bracketsStainless steel or galvanized steel guard with external aluminium protectionExternal aluminium protection recommended for outdoor installationsCable gland: FGAB2NBK for armoured cable or FB2NBK for non-armoured cable (only for FLF...L)Lighting fixture with separate emergency battery pack for temperatures of -20°C +55°C only for FLFE...L (code FLFE-101LEF7E)Rated voltage: 110/230 Vac/dc (FLFE-.../S) 110/277 Vac/dc (FLF-.../277)Cable entry: 2 x ISO M20 holes. Lighting fixture with 1 model PLG1IB plugs and 1 model NAV20SIB cable glands for non-armoured cable (code FLFE-101LEF4/20)
ACCESSORIES AVAILABLE / SPECIAL REQUESTS
ELECTRICAL FEATURES
Rated voltage: 110/277 Vac (FLF/FLFE-102L, FLF/FLFE-201L) 220/240 Vac (FLF/FLFE-101L, FLF/FLFE-202L)Rated frequency: 50/60 HzConnection: Direct to the terminal board L, N, Pe section 4 mm2 with jumpers suitable for input/outputPower factor: >0,98Emergency unit: Electronic inverter 110V/240V, 50/60Hz. Batteries Ni/Cd, 4 Ah o 7 Ah, 6 VWiring: Silicone rubber cables with glass braid insulation for high temperaturesSafety: Internal safety switch installed for emergency lighting fixtures
Body: Low copper content aluminium alloy headsExternal tube: Shock and high temperature resistant borosilicate glassGaskets: Acid/hydrocarbon resistant NBR on coversInner frame: White painted aluminium that acts as reflectorBolts and screws: Stainless steelCap chain: Stainless steelMounting: 2 x M8 holesEntries: 2 x ISO M25 entries for FLFE, fixture kit with PLG2IB plug and NAV25IB cable gland 2 x 3/4” threaded NPT for FLF. Fixture set with 1 x PLG2NA plugCoating: Polyester coating Ral 7035 (Light grey)
: The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot/humid cycles) and EN60068-2-11 (salt mist tests)
NOTE: The technical and electrical specifications may be changed without notice due to continuous developments of LED technology.
102ED.2019
FLFE...L, FLF...L series Lighting fixtures with LED strips
DIMENSIONAL DRAWING
DIMENSIONAL DRAWING
Code Dimensions mm Strips
n°Power supply Watt
Weightkg
mmA A1 B C
FLFE-101L 725 640 142 197 1 220/240 Vac 21 5,0 240x230x800
FLFE-201L 725 640 142 197 2 110/277 Vac 34 5,1 240x230x800
FLFE-102L 1325 1240 142 197 1 110/277 Vac 34 7,8 240x230x1410
FLFE-202L 1325 1240 142 197 2 220/240 Vac 61 7,9 240x230x1410
Code Dimensions mm Strips
n°Power supply Watt
Weightkg
mmA A1 B C
FLF-101L 725 640 142 145 1 220/240 Vac 21 4,5 240x230x800
FLF-201L 725 640 142 145 2 110/277 Vac 34 4,6 240x230x800
FLF-102L 1325 1240 142 145 1 110/277 Vac 34 7,3 240x230x1410
FLF-202L 1325 1240 142 145 2 220/240 Vac 61 7,4 240x230x1410
Ex de lighting fixtures
Ex d lighting fixtures
103 ED.2019
FLFE...L, FLF...L series Lighting fixtures with LED strips
DIMENSIONAL DRAWINGSDimensions in mm
CodeDimension mm
Operatingtype
N° ofstrips
Powersupply
Lumen*(in
emergency)Watt
Dischargetime
in minutes
Weightkg
mmA A1 B C
FLFE-101LEF4 725 640 142 197 normal+emergency 1 220/240 Vac 1847 lm 21 180’ 5,5 240x230x800
FLFE-201LEF4 725 640 142 197 normal+emergency 2 110/277 Vac 1847 lm 34 180’ 5,6 240x230x800
FLFE-102LEF4 1325 1240 142 197 normal+emergency 1 110/277 Vac 3688 lm 34 180’ 8,3 240x230x1410
FLFE-202LEF4 1325 1240 142 197 normal+emergency 2 220/240 Vac 3688 lm 61 180’ 8,4 240x230x1410
FLFE-101LEF7 725 640 142 197 normal+emergency 1 220/240 Vac 1847 lm 21 240’ 5,5 240x230x800
FLFE-201LEF7 725 640 142 197 normal+emergency 2 110/277 Vac 1847 lm 34 240’ 5,6 240x230x800
FLFE-102LEF7 1325 1240 142 197 normal+emergency 1 110/277 Vac 3688 lm 34 240' 8,4 240x230x1410
FLFE-202LEF7 1325 1240 142 197 normal+emergency 2 220/240 Vac 3688 lm 61 240’ 8,4 240x230x1410
FLFE-101LEE4 725 640 142 197 only emergency 1 220/240 Vac 1847 lm 21 180’ 5,5 240x230x800
FLFE-102LEE4 1325 1240 142 197 only emergency 1 110/277 Vac 3688 lm 34 180’ 8,3 240x230x1410
FLFE-101LEE7 725 640 142 197 only emergency 1 220/240 Vac 1847 lm 21 240’ 5,5 240x230x800
FLFE-102LEE7 1325 1240 142 197 only emergency 1 110/277 Vac 3688 lm 34 240' 8,4 240x230x1410
104ED.2019
FLFE...L, FLF...L series Lighting fixtures with LED strips
Codice Dimension mm
Operatingtype
N° ofstrips
Powersupply
Lumen*(in
emergency)Watt
Dischargetime
in minutes
Weightkg
mmA A1 B C
FLF-101LEF4 725 640 142 197 normal+emergency 1 220/240 Vac 1847 lm 21 180’ 5,0 240x230x800
FLF-201LEF4 725 640 142 197 normal+emergency 2 110/277 Vac 1847 lm 34 180’ 5,1 240x230x800
FLF-102LEF4 1325 1240 142 197 normal+emergency 1 110/277 Vac 3688 lm 34 180’ 7,8 240x230x1410
FLF-202LEF4 1325 1240 142 197 normal+emergency 2 220/240 Vac 3688 lm 61 180’ 7,9 240x230x1410
FLF-101LEF7 725 640 142 197 normal+emergency 1 220/240 Vac 1847 lm 21 240’ 5,0 240x230x800
FLF-201LEF7 725 640 142 197 normal+emergency 2 110/277 Vac 1847 lm 34 240’ 5,1 240x230x800
FLF-102LEF7 1325 1240 142 197 normal+emergency 1 110/277 Vac 3688 lm 34 240' 7,9 240x230x1410
FLF-202LEF7 1325 1240 142 197 normal+emergency 2 220/240 Vac 3688 lm 61 240’ 7,9 240x230x1410
FLF-101LEE4 725 640 142 197 only emergency 1 220/240 Vac 1847 lm 21 180’ 5,0 240x230x800
FLF-102LEE4 1325 1240 142 197 only emergency 1 110/277 Vac 3688 lm 34 180’ 7,8 240x230x1410
FLF-101LEE7 725 640 142 197 only emergency 1 220/240 Vac 1847 lm 21 240’ 5,0 240x230x800
FLF-102LEE7 1325 1240 142 197 only emergency 1 110/277 Vac 3688 lm 34 240' 7,9 240x230x1410
DIMENSIONAL DRAWINGSDimensions in mm
105 ED.2019
FLFE...L, FLF...L series Lighting fixtures with LED strips
DON’T FORGET TO ORDER THE ACCESSORIES
Example: Type of lighting fixture FLF-201L
other ...see key+ +Type P bracket
G-0480SPARE PART
ACCESSORY
Electrical features FLF/FLFE...101L FLF/FLFE...201L FLF/FLFE...102L FLF/FLFE...202L
Power supply: 220-240 Vac 110-277 Vac 110-277 Vac 220-240 Vac
Rated frequency: 50-60 Hz 50-60 Hz 50-60 Hz 50-60 HzN° of LED strips:
1 2 1 2
Power consumption: 21 W* 34 W* 34 W* 61 W*
Connection: Direct connection to terminal board L, N, Pe.Section 4mm2, suitable for loop-in/loop-out
Power factor: >0,94 * >0,93 * >0,93 * >0,98 *
Rated current: 81 mA* 146 mA* 146 mA* 265 mA*
EMC (electromagnetic compatibility):
EN 55015, EN 61547, IEC 61000-3-2, IEC 61000-3-3
THD (total harmonic distortion): <4% 230 Vac, 50 Hz
Over-voltage protection: 4 kV 4 kV 4 kV 4 kV
Driver performances: Over-Voltage protection, Over-Current protection, Short-Circuit protection
Photometric features
LED: LED strips
Viewing angle: 120° 120° 120° 120°
Colour temperature: 5000 K 5000 K 5000 K 5000 K
CRI: 80 80 80 80
Instant Restrike: Yes Yes Yes Yes
Lumen: 1900 lm 3934 lm 3700 lm 7828 lm
Maximum light intensity: 678 cd 1330 cd 1311 cd 2659 cd
Overall efficiency: 91 lm/W 116 lm/W 110 lm/W 128 lm/W
ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY
Tige Longitud:250 mm
Material:stainless steel
BRF8MIN/250 SPARE PART
ACCESSORY
Type O eyebolt Material:galvanised steel
GOF-8 SPARE PART
ACCESSORY
Type U bracketcomplete with screws
Material:bracket: galvanised steel
screws: stainless steelG-0609 SPARE PART
ACCESSORY
Type V bracketcomplete with screws
Material:bracket: galvanised steel
screws: stainless steelG-0610 SPARE PART
ACCESSORY
* Test at 230Vac
106ED.2019
FLFE...L, FLF...L series Lighting fixtures with LED strips
ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY
Type D bracketcomplete with screws
Material:bracket: galvanised steel
screws: stainless steelG-0611 SPARE PART
ACCESSORY
Type P bracket Material:galvanised steel
G-0480 SPARE PART
ACCESSORY
Guard withLight blue/white
painted10/10 aluminium
external protection
FLF/FLFE.....1LStainless steel guard
G18-0529
SPARE PART
ACCESSORY
FLF/FLFE.....2L G36-0529
FLF/FLFE.....1LGalvanised steel guard
G18-0529G
FLF/FLFE.....2L G36-0529G
External protection
FLF/FLFE.....1L Light blue/white painted10/10 aluminium
external protection
G18-568
SPARE PART
ACCESSORY
FLF/FLFE.....2L G36-568
FLF/FLFE.....1L 10/10 stainless steelAISI 304
external protection
G18-568IN
FLF/FLFE.....2L G36-568IN
Cable gland FLF...LFor models and codes,
visitwww.cortemgroup.com
FB2NBKFGAB2NBK
SPARE PART
ACCESSORY
FLF/FLFE...101L220/240 Vac
50/60Hz220/240 Vdc
LEDDEXEL115L
RICAMBIO
ACCESSORIO
FLF/FLFE...201LFLF/FLFE...102L
110/277 Vac50/60 Hz
110/277 VdcLEDDEXEL215L
FLF/FLFE...202L220/240 Vac
50/60 Hz220/240 Vdc
LEDDEXEL230L
Inverter 110/230 V50/60 Hz
INVERTER/LED/1 SPARE PART
ACCESSORY
Battery pack
4Ah 6V NiCd BATT4AH/D
RICAMBIO
ACCESSORIO
7Ah 6V NiCd BATT7AH/D
Re-lamping bracketwith clip system for
use on in-line lightingfixtures
Material:galvanised steel
G-0318+
G-0318/1
SPARE PART
ACCESSORY
107 ED.2019
45° angle mountingTYPE “D”
Pendant mounting witheyebolt TYPE “O”
Mounting using 1.1/2”metal clamps TYPE “P”
Low ceiling mounting withclamp TYPE “U”
High ceiling mounting withclamp TYPE “V”
Pole mounting for FLF...Lwith barrier cable gland
Tube ø1 1/2”
Type P clamp
Installation and mounting methods and photometric diagrams
FLF/FLFE...101L
FLF/FLFE...102L
FLF/FLFE...201L
FLF/FLFE...202L
108ED.2019
Installation and mounting methods and photometric diagrams
On Cortem Group web site you can download .LDT and .IES lighting data files for the design and simulation of lighting levels in 2D and 3D, rendering and ray tracing.
= plane 90270= plane 0180