flf-22l (ex d) and flfe-22l (ex de) series lighting fixtures with led tubes · 2013. 10. 12. ·...

6
1 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures FLF-...22L (Ex d) and FLFE-...22L (Ex de) series lighting fixtures with LED tubes TECHNICAL DATA SHEET NEW PRODUCT Rev. 0 – 05/2013

Upload: others

Post on 01-Mar-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FLF-22L (Ex d) and FLFE-22L (Ex de) series lighting fixtures with LED tubes · 2013. 10. 12. · • Off-shore rig constructors • On-shore treatment and refining plants CORTEM GROUP

1 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures

FLF-...22L (Ex d) and FLFE-...22L (Ex de) series lighting fixtures with LED tubes

TECHNICAL DATA SHEET NEW PRODUCT Rev. 0 – 05/2013

Page 2: FLF-22L (Ex d) and FLFE-22L (Ex de) series lighting fixtures with LED tubes · 2013. 10. 12. · • Off-shore rig constructors • On-shore treatment and refining plants CORTEM GROUP

2 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures

1. The symbol CE means "Conformité Européenne" and it shows that the item is complying the essential requirements of the Directives on safety, public health, consumer protection, ecc

2. N° of the registered body (CESI) responsible for production monitoring in accordance with Directive 94/9/CE ATEX

3. Denotes the equipment with explosion protection 4. Group II (surface devices) 5. Category 2 (suitable for zone 1 and 2 for gas and zone 21 and 22 for dust) 6. Gas and Dust (this material can be installed both in presence of gas and dust) 7. Protection mode for gas (Ex de: Explosion-proof enclosure with increased safety cable entry, IIC: gas

group) 8. Class of temperature 9. Epl – Equipment protection level 10. Protection mode for dust (Ex tb: protection for dust, IIIC: dust group) 11. Maximum temperature that the equipment can reach during operation with its relevant ambient tempe-

rature 12. Epl – Equipment protection level 13. IP protection

MARKING

ZONE 1 - 21 - 2 - 22

IP PROTECTION IP66

ATEX CERTIFICATION CESI 09 ATEX 008

IECEX CERTIFICATION IECEx CES 11.0021

CONFORMITY TO STANDARDS

ATEX 94/9/CE standard

EN60079-0, EN60079-1, EN60079-7, EN60079-31

OTHER CERTIFICATIONS Will follow upon market demand

CERTIFICATION DATA AND CONFORMITY TO STANDARDS

Page 3: FLF-22L (Ex d) and FLFE-22L (Ex de) series lighting fixtures with LED tubes · 2013. 10. 12. · • Off-shore rig constructors • On-shore treatment and refining plants CORTEM GROUP

3 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures

PRODUCT DESCRIPTION

Lighting fixtures for LED tubes FLF-...22L (Ex d) and FLFE-...22L (Ex de) series have two low copper con-

tent aluminium heads with G13 lamp holder, a tempered borosilicate glass tube, that is resistant to chan-

ges in heat, and a white painted aluminium reflector. Both the series are available with one tube or with two

tubes. FLFE-...22L series, in ‘Ex de’ way of protection, features an “Ex e” terminal board housing that al-

lows entry to the fixtures with a cable gland with an “Ex” seal (normal), while FLF-...22L series, in ‘Ex d’

way of protection, as specified in the appropriate installation standard (EN/IEC 60079-14), the entry to the

fixture must be through an Ex “barrier” cable gland (sealed) or, in the case of a conduit system, with an

EYS, EZS series sealing fittings.

The use of LED tubes, which have the same dimentions of fluorescent ones, allows to obtain economy in

operating costs, due to their long life, high-efficiency lighting, thanks to directional light, and LED light qua-

lity with a color rendering index of 85 (CRI).

Furthermore, LEDs do not ionize the particles of air around the lamp and do not attract, then, the dust par-

ticles suspended in the air.

The round cross section of the lighting fixtures provides a better “Cx” coefficient with less resistance to the

wind and less accumulation of dust. FLFE series has been designed to facilitate and speed up maintenan-

ce operations. As the electrical components are housed on a frame with guides, re-lamping is quick and

efficient. Furthermore, the different types of mounting attacks and the absence of sealing fittings make the

armor particularly performant.

Further advantages are as follows:

1) LED operation does not need heating times typical of discharge lamps. It has an instant lighting at star-

ting or restarting called instant restrike;

2) light diffusion is only in the visible spectrum avoiding, therefore, the emissions of UV rays (dangerous to

humans) or infrared radiation (they attract insects and do not facilitate cleaning operation);

3) the absence of heavy metals or toxic substances and their relevant disposal problems and environmen-

tal impact;

4) low class temperature T6;

5) LED tubes are supplied along with the lighting fixture.

MODELS AVAILABLE

Codes of models with one-tube Codes of models with two tubes

FLF (Ex d) series FLF-122L FLF-222L

FLFE (Ex de) series FLFE-122L FLFE-222L

Page 4: FLF-22L (Ex d) and FLFE-22L (Ex de) series lighting fixtures with LED tubes · 2013. 10. 12. · • Off-shore rig constructors • On-shore treatment and refining plants CORTEM GROUP

4 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures

CONSTRUCTIVE FEATURES

MACHANICAL FEATURES 1. Heads in aluminium alloy with low copper content, RAL7035 epoxy coated as a standard 2. Borosilicate glass tube, resistant to shocks and high temperatures 3. Internal mounting plate in aluminium, white painted, performing as a reflector too (standard) 4. Silicone resin between glass tube and aluminium heads 5. External protection in white painted aluminium and stainless steel protection guard (upon request) 6. PLG2IB plug and FL2IBK cable gland nickel plated brass (“Ex de” version), PLG2N plug(“Ex d” ver-

sion). 7. Neoprene sealing gaskets, resistant to acids and hydrocarbons 8. Stainless steel screws

ELECTRICAL FEATURES

• Rated Voltage: 100-240V

• Power: 1 or 2 tubes x 22 W

• Direct connection to terminal sboard L, N, Pe section 4mm2

• Bi-pin lamp-holder, type G13

• Internal wiring in silicone rubber cables, high temperature resistant

• Possibility to loop-in / loop-out connection betwe-en multiple installed fixtures

Page 5: FLF-22L (Ex d) and FLFE-22L (Ex de) series lighting fixtures with LED tubes · 2013. 10. 12. · • Off-shore rig constructors • On-shore treatment and refining plants CORTEM GROUP

5 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures

TEMPERATURE CLASS, MAXIMUM SURFACE TEMPERATURE, AMBIENT TEMPERATURE

Ambient Temperature Temperature Class Maximum surface temperature

-20°C +55°C T6 67°C

DIMENTIONAL DRAWINGS

FLFE SERIES

FLF SERIES

Page 6: FLF-22L (Ex d) and FLFE-22L (Ex de) series lighting fixtures with LED tubes · 2013. 10. 12. · • Off-shore rig constructors • On-shore treatment and refining plants CORTEM GROUP

6 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures

APPLICATION

• Manufacturing plants and process facilities: chemi-cal, petrochemical, refineries, pharmaceutical, Gas treatment and transport

• Areas with risk of explosion and fire due to abnor-mal, unusual or accidental presence of ignitible concentration of gases/vapours and dusts, even simultaneously

• On-shore, off-shore, naval and harbor installations

• Waste and or sewage treatment facilities

• Thermal plants

• Area with presence of combustible dusts such as joineries, sugarhouses, food industries with treat-ment and storage of wheat and derivatives

• Painting Systems

MARKET

• Industry

∗ Mechanical and electrical engineering

∗ Agribusiness

∗ Distillery

∗ Oil & Gas industries

∗ Pharmaceutical industries

∗ Energy

• Engineering and Contractors

∗ Project Design companies

∗ Electrical contractors

∗ Construction companies

• Electrical equipment distributors

• Shipyards / harbours

• Off-shore rig constructors

• On-shore treatment and refining plants

CORTEM GROUP

HEADQUARTERS AND FACTORY

Via Aquileia 10, 34070 Villesse (GO) ITALY

Tel +39 0481 964911

Fax +39 0481 964999

[email protected]

SALES

P.le Dateo 2, 20129 Milano ITALY

Tel +39 02 76110501

Fax +39 02 70005471

[email protected]

www.cortemgroup.com

PHOTOMETRIC DIAGRAM OF FLF-222L AND FLFE-222L SERIES