flexible tray cable - olflex.com.mxolflex.com.mx/estructura/archivos/pdf/cable_para_charola.pdf ·...

7
Flexible Tray Cable 69

Upload: vuongdang

Post on 09-Aug-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Flexible Tray Cable

69

Flexible Tray Cable

70 Visit our website for additional information and updates.

UNITRONIC® 300/ 300 CY UL/CSA/CE/NOM 71Multi-Conductor Low Voltage Control &Signal Cable for Industrial Applications

OLFLEX® TRAY II & TRAY II CY UL/CSA/CE/NOM 73Flexible and Oil Resistant Tray Cable with both UL & CSA TC Approval for Industrial Applications

OLFLEX® TRAY II NAC UL/CSA/CE/NOM 75Flexible and Oil Resistant Tray Cable Color Coded for Industrial ApplicationsBus Drop Cable

OLFLEX® AUTO I UL/CSA/CE/NOM 76Heavy Duty Flexible Control Cable

UNITRONIC® 300/ 300 CYMulti-Conductor Low Voltage Control &Signal Cable for Industrial Applications

71Visit our website for additional information and updates.

Technical Data:

UNITRONIC® 300 Construction:Finely stranded tinned copper conductors; PVC blended insulation; oil resistant gray PVC jacket.

UNITRONIC® 300 (UL) TYPE CMG or PLTC 105°C CSA CMG or AWM II A/B 300V pbf(+)

UNITRONIC® 300 CY (UL) TYPE CMG or PLTC 105°C CSA CMG or AWM II A/B 300V pbf(+)

Minimum bend radiusfor installation: 4 x cable diametershielded: 6 x cable diameter

Temperature Range: -25°C to +105°C

Nominal voltage: 300V

Test voltage: 2000V

UNITRONIC® 300 CY Construction:Finely stranded tinned copper conductors; PVC blended insulation; overall foil tape wrap; drainwire; tinned copperbraid (75% coverage); oil resistant gray PVC jacket.

pbf(+)= Meets RoHS Standard- (2002/95/EC) Restriction of Hazardous Substance Directives

PLTC

Color code: 24 - 22 AWG- Chart 4, Page 6731 Pair= White paired with Black20 - 16 AWG- Chart 5, Page 6731 Pair= Black paired with Red

Approvals: UL CMG, PLTC*, Open Wiring**, AWM 2464, Oil Res ICSA CMG/FT4, CSA AWM II A/BNOM SCFI-1994

* 24 AWG not PLTC** Open Wiring for 18 AWG & 16 AWG (22 & 20 AWG Available)Meets NEC Art. 725, 760, & 800. Also Class I Div. 2 (PLTC only)Conforms to CE Low Voltage Directive

RoHS Standard: Cables that meet RoHS do not contain Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls(PBB), Polybrominated Diphenyl Ethers (PBDE). RoHS is a European Directive to be met by July 1, 2006.

UNITRONIC® 300 (UL) TYPE CMG or PLTC 105°C CSA CMG or AWM II A/B 300V pbf(+)

Open Wiring, No Conduit Necessary16 & 18 AWG

Per NEC Article 725

Control Cable (20 AWG - 16 AWG)

Signal Cable (24 AWG* - 22 AWG)

OR-02

FR-03

FL-01

MP-03

Cable AttributesJacket is dual printed with AWG/mm2 equivalent.

UNITRONIC® 300 is a lead free, rugged multi-conductorlow voltage control and signal cable for internal and external wiring of OEM equipment for industrial applications. UNITRONIC® 300 has multiple approvalssuch as UL Type PLTC, UL CMG, UL Oil Res I, CSA CMG,and CE. PLTC with open wiring approval allows for use inoverhead trays eliminating the need for conduit.

With these multiple approvals, the cable can be used inprocess control equipment, electrical equipment, plantexpansion, and other machinery. UNITRONIC® 300 also isUV Resistant and is approved for direct burial and meetsClass 1 Div. 2 requirements.

UNITRONIC® 300 CY, a shielded version, is also available.

*Higher conductor sizes available upon request. May be subject to 5,000 ft. minimum order.

UNITRONIC® 300/ 300 CYMulti-Conductor Low Voltage Control &Signal Cable for Industrial Applications

72

(UL) PLTC

*Higher conductor sizes available upon request. May be subject to 5,000 ft. minimum order.

UNITRONIC® 300 CY: Shielded Multi-Conductor Lead Free Control & Signal Cable

UNITRONIC® 300: Multi-Conductor Lead Free Control & Signal Cable

Visit our website for additional information and updates.

24 AWG (19/36) 0.25 mm2

302401TP302402302403302404302406302408302410302415302420302425

22 AWG (19/34) 0.34 mm2

302201TP302202302203302204302206302208302210302215302220302225

20 AWG (19/32) 0.75 mm2

302001TP302002302003302004302006

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

.154

.165

.172

.183

.209

.223

.253

.284

.321

.355

.165

.177

.185

.198

.227

.243

.277

.312

.353

.414

.205

.223

.235

.254

.296

3.94.24.44.75.35.76.47.28.29.0

4.24.54.75.05.86.27.07.99.0

10.5

5.25.76.06.57.5

13131518232834465870

15151922313745617895

3838405065

191922273442516986

104

2222283346556791

116142

5757607497

302008302010302015302020302025

18 AWG (19/30) 1.00 mm2

301801TP301802301803301804301806301808301810301815301820301825

16 AWG (26/30) 1.50 mm2

301601TP301602301603301604301606301608301610301615301620301625

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

810152025

1 (pr)2346810152025

1 (pr)2346810152025

.329

.379

.452

.497

.554

.221

.241

.254

.285

.333

.358

.437

.494

.544

.629

.240

.263

.288

.312

.366

.417

.481

.546

.603

.696

8.49.6

11.512.614.1

5.66.16.57.28.59.1

11.112.513.816.0

6.16.77.37.99.3

10.612.213.915.317.7

9096

120174238

414143536994

131166221275

56566074

110164180243331409

134143178259354

61616479

103140195247329409

838389

110164244268362475609

1 (pr)2346810152025

1 (pr)2346810152025

1 (pr)2346

24 AWG (19/36) 0.25 mm2

302401STP302402S302403S302404S302406S302408S302410S302415S302420S302425S

22 AWG (19/34) 0.34 mm2

302201STP302202S302203S302204S302206S302208S302210S302215S302220S302225S

20 AWG (19/32) 0.75 mm2

302001STP302002S302003S302004S302006S

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

.186

.190

.197

.208

.234

.248

.288

.319

.346

.380

.197

.202

.210

.223

.252

.278

.312

.347

.378

.445

.241

.248

.260

.289

.331

4.74.85.05.35.96.37.38.18.89.7

5.05.15.35.76.47.17.98.89.6

11.3

6.16.36.67.38.4

25252732374553668095

2929333846556684

103132

4040425980

3737404855677998

119142

43434957688298

125153197

60606388

119

302008S302010S302015S302020S302025S

18 AWG (19/30) 1.00 mm2

301801STP301802S301803S301804S301806S301808S301810S301815S301820S301825S

16 AWG (26/30) 1.50 mm2

301601STP301602S301603S301604S301606S301608S301610S301615S301620S301625S

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

810152025

1 (pr)2346810152025

1 (pr)2346810152025

.354

.426

.483

.528

.585

.258

.266

.289

.310

.358

.383

.468

.525

.575

.660

.289

.298

.313

.337

.391

.448

.512

.577

.654

.727

9.010.812.313.414.9

6.66.87.37.99.19.7

11.913.314.616.8

7.37.68.08.69.9

11.413.014.716.618.5

105107154194245

50505770

109120146212246301

686884

121141180210342402495

156159229289365

757585

104162179217315366448

101101125180210268313509598737

1 (pr)2346810152025

1 (pr)2346810152025

1 (pr)2346

OLFLEX® TRAY II/ II CYFlexible and Oil Resistant Tray Cable with both UL & CSA TC Approval for Industrial Applications

73Visit our website for additional information and updates.

Optional color code for the conductors and the jacket are available upon request. Minimums may apply.

(UL)

*UL Type TC-ER stands for “ exposed run” and is replacing the term “open wiring”. It is a change in terminology only.

OLFLEX® Tray II Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; specially formulated oil resistantblack PVC jacket.

OLFLEX® Tray II CY Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; 100% shielding with foil tape andtinned copper braid; specially formulated oil resistant black PVC jacket

Minimum Bending Radiusfor installation: 5 x cable diameter

Temperature Range: -40oC to +90oC

Nominal Voltage: 600V - TC1000V- AWM

Conductor Stranding: Fine wire

Color Code: Black with white numbersplus green/yellow ground

Approvals: UL Type TC-ER (Exposed Run)* or DP-1

UL Type MTW or UL AWM, Oil Res IClass 1, Div. 2 per NEC Art. 336, 392, 501c(UL) Type TC and CIC FT4

CSA-AWM I/II A/B FT4

NOM SCFI-1994

Conforms to CE Low Voltage Directive

Technical Data:

OLFLEX® TRAY II CY-(UL)TYPE TC-ER OR DP-I 90OC 600V---c(UL) TC/CIC FT4--CSA AWM FT4 pbf(+)

OR-02

FR-03

FL-01

MP-03

Cable AttributesJacket is dual printed with AWG/mm2 equivalent.

OLFLEX® TRAY II -(UL)TYPE TC-ER OR DP-I 90OC 600V---c(UL) TC/CIC FT4--CSA AWM FT4 pbf(+)

OLFLEX® Tray II is a global multi-conductor, 1000 Volt, 90oC,UL Type TC-ER* and MTW, c(UL) Type TC/CIC, CE compliant, oil resistant and flexible control cable withexposed run approval. It is also UV resistant and approvedfor direct burial. Due to OLFLEX® Tray II’s higher stranding,precision extruded jacket, worldwide approvals, and Lapp’srenowned quality, OLFLEX® Tray II is a superior alternativeto stationary TC cables. These advantages make

installations much easier and quicker, and ensure the cable will hold up to your industrial requirements. OLFLEX®

Tray II control cables are designed for use in all electricalequipment in dry, damp, and wet conditions. OLFLEX® TrayII CY has an overall foil tape and tinned copper braid that is recommended whenever electrical interference distorts signal transmission, or when EMI emissions need to be suppressed.

OLFLEX® TRAY II/ II CYFlexible and Oil Resistant Tray Cable with both UL & CSA TC Approval for Industrial Applications

74

18 AWG (19/30) 1.00 mm2

221803221804221805221807221809221812221818221825221850

16 AWG (26/30) 1.32 mm2

221603221604221605221607221608221609221612221616221618221625221641221650221661

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

.296

.320

.346

.373

.429

.477

.587

.677

.939

.321

.347

.377

.406

.438

.467

.527

.617

.647

.748

.9561.0361.087

7.58.18.89.5

10.912.114.917.223.9

8.18.79.5

10.211.011.813.415.716.419.024.326.327.6

576677

100112171245322646

698398

127136171220271289397625760769

8598

115149167255365479961

103124146189203255328403431592931

11321148

14 AWG (41/30) 2.08 mm2

221403221404221405221407221409221412221418221425

12 AWG (65/30) 3.30 mm2

221204221205221207

10 AWG (105/30) 5.32 mm2

221004221005221007

8 AWG (168/30) 8.52 mm2

220804220805

6 AWG (266/30) 13.48 mm2

220604220605

4 AWG (413/30) 20.93 mm2

2204042 AWG (665/30) 33.70 mm2

220204

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

34579121825

457

457

45

45

4

4

.348

.378

.410

.445

.515

.610

.712

.826

.437

.475

.556

.573

.623

.677

.757

.874

.853

.982

1.098

1.272

8.89.6

10.411.313.115.518.121.0

11.112.114.1

14.615.817.2

19.222.2

21.724.9

27.9

32.3

87107128169225308439587

152187258

265317443

412518

580725

952

1394

130159191252335459654874

226279384

394472661

615771

8641080

1418

2077

OLFLEX® Tray II: Flexible and Oil Resistant Tray Cable

3457912182550

34578912161825415061

*UL Type TC-ER stands for “ exposed run” and is replacing the term “open wiring”. It is a change in terminology only.

OLFLEX® Tray II CY: Shielded Flexible and Oil Resistant Tray Cable

18 AWG (19/30) 1.00 mm2

221803S221804S221805S221807S221812S 221818S 221825S

16 AWG (26/30) 1.32 mm2

221603S221604S 221605S 221607S 221612S221618S221625S

14 AWG (41/30) 2.08 mm2

221403S 221404S 221405S 221407S 221412S 221418S221425S

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

.322

.346

.371

.398

.518

.628

.718

.346

.372

.400

.431

.597

.683

.794

.374

.410

.442

.476

.651

.748

.873

8.28.89.4

10.113.216.018.2

8.89.4

10.210.915.217.320.2

9.510.411.212.116.519.022.2

8092

100130222294386

97116127165286346476

121150180220400527704

119137149193330438574

144173189246426515708

180223268327595784

1048

12 AWG (65/30) 3.30 mm2

221204S 221205S 221207S

10 AWG (105/30) 5.32 mm2

221004S 221005S221007S

8 AWG (168/30) 8.52 mm2

220804S 6 AWG (266/30) 13.48 mm2

220604S4 AWG (413/30) 20.93 mm2

220404S2 AWG (665/30) 33.70 mm2

220204S

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

457

457

4

4

4

4

.468

.506

.587

.604

.654

.708

.801

.929

1.127

1.309

11.912.814.9

15.316.618.0

20.3

23.6

28.6

33.2

212261335

371412575

576

812

1332

1951

315388499

552613856

857

1208

1982

2903

3457121825

3457121825

3457121825

Visit our website for additional information and updates.

(UL)

OLFLEX® Auto-IHeavy Duty Flexible Control Cable

76 Visit our website for additional information and updates.

Optional color code for the conductors and the jacket are available upon request.

Jacket is dual printed with AWG/ mm2 equivalent.

Minimums may apply.

OLFLEX® Auto-I Construction:Finely stranded bare copper conductors; specially formulated PVC/nylon insulation; specially formulated gray PVC jacket.

Minimum Bending Radiusfor installation: 5 x cable diameter

Temperature Range: -25oC to +90oC

Nominal Voltage: 600V

Conforms to CE Low Voltage Directive

Color Code: Red (R) or Blue (B) with black numbers,plus green/yellow groundFor blue: No. 2 cond. is white with blue stripeFor red: No. 2 cond. is white3 cond: 2 base color plus green/yellow ground

Approvals: UL Type TC-ER (Exposed Run)*UL Type MTWOil Res. IClass 1 Div. 2 per NEC Art. 336, 392, 501CSA-AWM I/II A/B FT4NOM SCFI-1994

Technical Data:

18 AWG (19/30) 1.00 mm2 (BLUE)251803IB251805IB251807IB251811IB251812IB251819IB251825IB251833IB251842IB251849IB251865IB

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

.297

.346

.373

.463

.477

.583

.677

.736

.818

.9081.011

7.58.79.4

11.812.114.817.218.720.723.025.6

5777

100157171254322397510620726

85115149234255378479590758917

1024

16 AWG (26/30) 1.32 mm2 (BLUE)251603IB251607IB251611IB251612IB251617IB251619IB251625IB251633IB251642IB251649IB251665IB

PartNumber

Number ofConductors

includes ground

Nominal OuterDiameter

inches mm

Approx.Weight

lbs/mft kg/km

37111217192533424965

.323

.409

.541

.557

.638

.643

.737

.816

.9501.0051.123

8.210.413.714.116.116.318.720.724.125.528.5

65125202220259285397510625760890

97186301325379424590758936

11321326

3571112192533424965

OLFLEX® AUTO-I (UL) TC-ER OR MTW 90OC 600V --- CSA AWM FT4 pbf(+)

OR-02

FR-03

FL-01

MP-03

Cable Attributes

Replace the B at the end of the P/N with R for red conductors or Y for yellow conductors or BK for black conductors

OLFLEX® Auto-I is a flexible UL Type TC approved multi-conductor cable suitable for use in dry, damp and wet conditions, as well as direct burial applications. It canwithstand temperatures of up to 90OC, and has worldwideapprovals including UL Type TC-ER*, UL Type MTW, CSAAWM, and CE. The finer stranding, specially formulated

PVC jacket, and worldwide approvals make this cable aneconomic alternative for TC approved control cables.These advantages, plus the renowned quality of Lapp,ensures that the cable will withstand your industrialrequirements.

*UL Type TC-ER stands for “ exposed run” and is replacing the term “open wiring”. It is a change in terminology only.