Flexible TPN and general infusion pumps for inpatient and homecare use
You gain maximum flexibility from the BodyGuard 323TM Ambulatory Infusion Pump and the BodyGuard 2CHTM Twin Channel Infusion Pump
Both pumps are suitable for TPN and general infusion in hospital, at home or on the move
Modes of operation• TPN–withoptionalrampup/downpattern
• Continuous–rateovervolumeorvolumeovertime
• Multi-Step–upto25stepsatdifferentrates
• Intermittent(TwinChannelonly)–fordoseprotocolsatsetintervals
• Dose(TwinChannelonly)–forweight-baseddosing
Applications• Totalparenteralnutrition
• Criticalcare
• Patienttransport
• Emergencymedicine
• Fluidreplacement
• Lipids
• Enzymereplacement
Intended use• Parenteral
• Intravenous
• Subcutaneous
• Percutaneous
• Intra-arterial
When you need a system which is accurate and reliable in all applications• TheBodyGuardpumpingmechanismensuresunparalleled accuracy
and linearity of infusion, even at the lowest rates, to meet thestandardsofyourmostdemandingspecialities
• Adjustable air-in-line detectionandocclusion pressure settingshelptopreventnuisancealarms
• The Post-Occlusion Bolus Reduction System will safely releasepressurefromtheline,followinganocclusion,withoutadministeringapotentialpost-occlusionbolus
• Adelayed-start infusionoptionmeansnoreminderandnoadditionalclinical intervention is neededonce thepumphasbeen set up forgeneralinfusion
When you need a system which is quick and easy to use, allowing you more time for your patient• Configurable modes of operationthatcanbesettopatientspeciality
areavailable,limitingset-uptimeandpossibleerrors
• Intuitive designmeansbothpumpsarequickandeasytoprogramme
When you need a safety-enhanced system which puts you in complete control•Thebuilt-in event logautomaticallyrecordsaccurateandreliable
dataonpumpuse
•Thelockable keypadpreventsmostinadvertentkeypresses
•Arange of alerts and alarmswilldrawimmediateattentiontoanypumpstatusrequiringintervention
When you need a pump which allows your patients to be treated at home• The intuitive, user-friendly design enables patients to confidently
andsafelyoperatethepumpthemselves
• The integral rechargeable battery gives them full mobility andfreedom
• Theyhaveachoice of rucksack colours and sizestosafely,easilyanddiscreetlycarrytheirdeviceinstyle
And to feel as comfortable as possible in hospital• Theaccurateandreliabledeliverysystemgivespatientsthepeace of
mindtoconcentrateontheirrehabilitation
• Theyhavethefreedom to ambulatewithorwithoutadripstand
PumpsProduct code Description
SBOM323A BodyGuard 323TM Ambulatory Infusion PumpIncludespump,internalstandard-lifeLi-polymerbattery(1800mAh),chargerbase(noLEDdisplay),usermanual,ACmainsleadandDCchargingcable
100-510PXSDC BodyGuard323TMAmbulatoryInfusionPump(only)SBOM121D BodyGuard 2CHTM Twin Channel Infusion Pump
Includespump,internalstandard-lifeLi-polymerbattery,pole-mountableLEDchargerunit,usermanualandACmainslead100-901PTM BodyGuard2CHTMTwinChannelInfusionPump(only)
BodyGuard 323TM AccessoriesProduct code Description
150-000X Carrypouch(reusable/washable)–100ml
150-001X Carrypouch(reusable/washable)–250ml
160-002XB 2litrerucksack-black
160-002XG 2litrerucksack-grey
160-002XP 2litrerucksack-pink
160-001X 3-litrerucksack–navyblue
130-050X2 Batteryadapter(2x9V)
196-000X DCchargingcable
150-331X Desktopcharger
150-314X Chargerbase(LEDdisplay)&DCchargingcable
150-314XM Chargerbase(noLEDdisplay)
130-050XA Standard-lifeLi-polymerbattery(1800mAh)
130-051X Extended-lifeLi-polymerbattery(3600mAh)
100-072XA ACmainslead
SBOMBODYCA BodyCommkitforBodyGuardAllcarrypouchesaccommodatepump,lockboxandfluidbag
BodyGuard 2CHTM AccessoriesProduct code Description
160-002XB 2litrerucksack-black
160-002XG 2litrerucksack-grey
160-002XP 2litrerucksack-pink
160-001X 3-litrerucksack–navyblue
150-313T Chargerbase(LEDdisplay)
100-072XA ACmainslead
Administration setsProduct code Colour Patient
connectionBag spike Length/
Priming vol.Free flow protection
Additional features
120-112XSFV Clear Luerlock Straight 280cm/10ml Anti-siphonvalve&clamp
1.2-micronfilter&primingvalve
120-160XSFM Clear Luerlock Straight 270cm/10ml Anti-siphonvalve&clamp
0.2-micronfilter
120-160XSV Clear Luerlock Straight 280cm/7ml Anti-siphonvalve&clamp
Primingvalve
100-160XSM Clear Luerlock Straight 180cm/5ml Anti-siphonvalve&clamp
120-000XBS Clear Luerlock Straight 240cm/16ml Anti-siphonvalve&clamp
150mlburette(15-micronfilterindripchamber),rollerclamp,Y-site
Allsetsarelatex-freewithanti-kinktubing.Lengthandprimingvolumeareapproximate
Technical specificationBodyGuard 323TM Ambulatory Infusion Pump BodyGuard 2CHTM Twin Channel Infusion Pump
Description Pistonmechanism,ambulatoryinfusionpumpwithasinglechannel
Pistonmechanism,ambulatoryinfusionpumpwithtwoindependentchannels.
Dimensions 114mm(height)x90mm(width)x40mm(depth) 89mm(height)x149mm(width)x41mm(depth)Mains and battery power supply
ACmainspower:110-240VAC,50/60Hz0.3Amax ACmainspower:110-240VAC,50/60Hz0.3Amax
Battery:rechargeableLi-polymer,7.4V,1800mAh(typical) Battery:rechargeableLi-polymer,7.4V,1800mAh(typical)Battery life 11.3h(average)infusing@350ml/h 7.5hinfusing@125ml/h
(bothchannelsinfusingsimultaneously)Modes of operation Totalparenteralnutrition(TPN),continuous,multi-step Totalparenteralnutrition(TPN),
continuous,25-step,intermittent,doseFlow rate 0.1ml/hto100ml/hin0.1ml/hincrementsand100ml/hto
1,200ml/hin1ml/hincrements.0.1ml/hto100ml/hin0.1ml/hincrementsand100ml/hto1,200ml/hin1ml/hincrements
Alerts LowBattery LowBatteryProgramNearlyComplete ProgramNearlyComplete
Alarms Air/UpstreamOcclusion Air/UpstreamOcclusionDownOcclusion DownOcclusionDoorOpen DoorOpenPumpPausedTooLong(unattended) PumpPausedTooLong(unattended)EndProgram EndProgramEndBattery EndBatteryMissingKey MissingKeyRestartPump RestartPumpSystem/TechnicalProblem System/TechnicalProblemWrongTPNData WrongTPNDataLockMode LockModeFatalError FatalError
CME Support – by your side throughoutTechnical supportYourtechnicalsupportneedsareourpriority.AsanISO13485certifiedsupport facility, we can offer you high-quality technical support andtraining,withservicesdevelopedbyourcustomersforourcustomers.
Youandyourteamwillbenefitfrommarket-leadingtechnicaltrainingandsupportservices.Wewillworkwithyoutoensureyoureceivethebestpossibleservicepackageforyourneeds.
TRAININGYourroleasbiomedicalengineer insupportingandmaintainingthesesophisticateddevices isa very importantone.That iswhyweofferarange of technical training courses andmaterialswhich are designedtogiveyoutheknowledgeandskills toexpertly supportyourchosendevices.
EQUIPMENTREPAIRANDSERVICINGOur team of highly skilled engineers will support you by ensuringcompetitive turnaround times. Prompt spare parts order fulfilment isguaranteedbyoursignificantstock-holdingcapability.
SERVICECONTRACTSWhenenteringintoaservicecontractwithCMEMedical,apartnership
isformedtoensureyourrequirementsareidentifiedandaddressedfromtheoutset.
Clinical supportYou and your team need the confidenceto competently and safely operate yourchosen infusion devices. That is whywehave developed a range of educationprogrammeswhich are basedon currentandwell-establishedprinciplesoflearningand training strategies andwhich follownational standards for medical devicetraining.
Your competency-based training canbe delivered either face to face or viae-learning.Wecanofferbothatthepointofpurchaseandperiodicallyasrequired.
YourdedicatedClinicalSupportSpecialistwillworkwithyoutodevelopatrainingplanwhichistailoredtoyourlocalneeds,fitforpurposeandwhichwillhelpyoutoachieveyourtrainingobjectives.Emphasiswillbeplacedon intensive training for youradvancedusers, allowingyou totakecontrolofyourowncascadetrainingasyourorganisationmovesforward.
BodyCommBodyCommisaneasy-to-useconfigurationsoftwareprogrammewhichenablesefficientandflexiblemanagementofallinfusionprotocolsstoredinyourBodyGuard323TMAmbulatoryInfusionPump.
Use BodyComm to:• Download,saveandprintarecordofthelast512sequentialstored
events,includingalarms,fromyourpumpeventlogfordisplayintextandgraphicformat
Data captured for each event:• Date&time
•Flowrate
• Volumeinfused
•Volumetobeinfused
• Protocoldata
•BatteryorACpower
• Stateofoperation(pumpoperating,alarmingetc.)
• Eventnumber
• Pumpserialnumber
Head OfficeKincraig Business ParkKincraig RoadBlackpool FY2 0PJFax: 01253 896648
Southern OfficeMilton Park Innovation Centre99 Milton ParkAbingdon OX14 4RYFax: 08704416093
Central Switchboard: email: [email protected] 01253 894646 www.cmemedical.co.uk
Our complete range of specialist infusion devices
For more information, please contact us using the details below
MKG
3232CH