flexible seawater desalination with lms100 gas...

15
Imagination at work Flexible Seawater Desalination With LMS100 Gas Turbine Using MED and RO Combinations Bulent Mehmetli / Richard Watkins POWER-GEN Middle East, 13 October 2014

Upload: tranthu

Post on 21-Apr-2018

223 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

Imagination at work Imagination at work Imagination at work

Flexible Seawater Desalination With LMS100 Gas Turbine Using MED and RO Combinations Bulent Mehmetli / Richard Watkins POWER-GEN Middle East, 13 October 2014

Page 2: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

LMS100 presentation contents

• GE’s Aeroderivative Gas Turbines and LMS100 genealogy

• Intercooler and secondary heat rejection options

• How Multi Effect Distillation is applied

• Customer benefits

2

GE Proprietary Information – Class I

Page 3: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

Gas turbine product line LM2500/TM2500

18-34 MW @ 41% eff. • Legacy engine: 40+years • 99% reliability; 1M OPHs

Applications • Emergency/temp power • Verticals: Mining, oil and gas • Marine: defense, fast ferry

Wins • Japan: Emergency response • Ecuador/Oman: Temp power • Brazil: FPSO/Oil & Gas

LM6000

40-60 MW+ @ 42% eff. • Intro ’91 … 1,000th unit ’10 • Fast response flexible CC … 140 MW @ 55+% efficiency

• Cleaner heat and power • LNG/Mechanical drive • Dual fuel DLE

• China: Huadian CHP • US: Black Hills, Colorado • Brazil: Sugarcane ethanol

LMS100

100-116 MW @ 44.5% • New DLE 2.0 technology • Global acceptance

• Grid stability • Power generation • Mechanical drive

• Russia: ’14 Olympics in Venue, Sochi • US: 23 (+5) California units

3

Page 4: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

CF6-80C2 • Introduced in ’85 • 3,800 units • 173 million hours

Design experience and commonality LMS100

LM6000 • Introduced in ’91 • 991 units • 21 million hours • 99% reliability • 98% availability

6FA • Introduced in ’96 • 100 units • 2.5 million hours

* LMS100 is a registered trademark of the General Electric Company (USA)

LMS100* Genealogy Building on proven technology

4

Page 5: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

MS6001FA Low Pressure Compressor (LPC) Aeroderivative

Intermediate Pressure Turbine (IPT)

Frame derivative Exhaust diffuser

Aeroderivative Power Turbine (LPT)

Frame derivative Power turbine shaft

Intercooler System

CF6-80C2 High Pressure Compressor (HPC)

CF6-80E High Pressure Turbine (HPT)

Aeroderivative Single annular or DLE combustor

Proven technologies integrated in a 3-shaft 100+ MW gas turbine package

5

Page 6: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

73 feet 22.2 meters

113 feet 34.4 meters

Current package dimensions

6

Page 7: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

Intercooler is the key to LMS100 performance Enables high mass flow, pressure ratio, hot-day power

VBV silencer

VBV system

Cooling water skid

LMS100

Frame Frame

Aero

Power reduction over ambient T

392 deg F (200 deg C)

56 psi

(3.9 bar)

95 deg F (35 deg C)

55 psi

(3.8 bar)

Intercooler water flow: 22,711 lpm (6,000 gpm) for 2-pass 52C (125 F) to 28C (82 F) 8,706 lpm (2,300 gpm) for 6-pass 90C (195 F) to 28C (82 F)

Page 8: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

Ideal T-S Diagram for an intercooled gas turbine cycle (using LMS100 thermodynamic cycle station numbers)

Entropy

Tem

pera

ture

2

23

25

3

41

50

Qcomb

Qic

Qexh

A fundamentally more efficient cycle is enabled by modern control technology

Note: Not drawn to scale High Pressure Compressor

Low Pressure Compressor

Page 9: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

Exhaust ~ 90 MWth, ~ 39%

LMS100 Energy Balance at Baseload, hot & humid day

9

Fuel~ 234MWth, LHV

Interc ooler ~ 34 MWth, ~ 15%

Generator power ~ 103 MWe, ~ 44%

Generator losses

Other losses

Rough figures, details depend on ambient and model conditions !

Page 10: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

CHP (CC + Intercooler Heat)

Fin Fan Cooler 35 0C

50 0C

Water 121 0C 300 t/hr

Heat Exchanger Process:

~ 27 MWt 11.5% eff.pts.

Steam Turbine: ~ 20.5 MWe

8.5% eff.pts.

Gas Turbine: ~ 103 MWe

44 % eff.pts.

TOTAL CHP 124 MWe+27 MWt

64 %

Page 11: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

Load Following / Deep Turndown Capability

11

Page 12: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

Cengiz Energy Samsun, Turkey (2) LMS100s in CC (250 MW) Cooling system uses seawater (Black Sea)

12

GE Proprietary Information – Class I

Page 13: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

Multiple Effect Distillation

Distillate vapor

Sea water (Distillate)

Tubes or plates

Bulb enclosure Vessel

Heating fluid from intercooler

Heating fluid back to intercooler

MED Advantages

• Low energy consumption

• Low temp operation

• Simple

• Reliable

• Low opex

Distillate

Page 14: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

MED – RO Combination

• LMS100 can operate at either CC or SC mode

• If SC is chosen, all exhaust heat is available for MED (or MSF if feasible)

• If CC is chosen:

• CC efficiency>52% for full condensing configuration

• Use extraction to increase MED capacity

• Use MED for Intercooler heat

• Use all extra heat (from condenser, stack and IC) for RO heating

• Adjust MED/RO according to power and water needs

Page 15: Flexible Seawater Desalination With LMS100 Gas …st-events.gepower.com/.../Desalination_with_LMS100_Mehmetli_PGME14.pdfImagination at work Flexible Seawater Desalination With LMS100

GE Proprietary Information – Class I

1. Fast starts … zero to 100% in 10 minutes

2. High efficiency ... +44% in SC

3. Fast response … 50 MW per minute ramp-up

4. Power for frequency support … reserved power, under frequency support

5. High part load efficiency ... for flexible operation

6. Multiple daily starts … no maintenance penalties

7. Cycle type … ability to run SC or CC

8. Zero water capable with DLE

9. High availability and reliability … longer maintenance intervals

15

LMS100 in Desalination Configuration … set the benchmark for defining operational flexibility while sustaining medium size power and water needs