82
Flare Tools
Deluxe Flare ToolFaceted, hard chrome finished cone rolls out and burnishes perfect 45O flare above the tube holding mechanism. Original wall thickness is maintained at the baseline of the flare. Large handle for good leverage and precision threads on feed screw make flaring effortless.1/8” thru 3/4” capacity.
945TH
Papco Flare ToolOne piece unit with swing away cone assembly facilitates quick easy flaring even in tight quarters.3/16” thru 5/8” capacity.
420
Rol-Air Flare ToolFlares roll out above the die bar by super smooth faceted cone. Automatically burnishes flare face. Slip-on yoke permits use in tight quarters. Heat treated dies grip tubing without scoring.3/16” thru 5/8” capacity.
Grabber Flare Tool
Large Size Flare Tool
Self adjusting tube holder permits flaring any size tubing within its range. Automatically burnishes flare face.3/16” thru 5/8” capacity.
Flares up to 1-1/8” O.D. tubing. Yoke fits over flare bar and locks into place. Long handle and precision threaded feed screw.3/4”, 7/8”, 1”, and 1-1/8” O.D. capacity.
500FC
525F
60290
Papco Cutting ToolEnclosed feed mechanism and wide rollers provide clean cuts on all grades of copper or aluminum tubing. Includes fold away reamer and spare cutting wheel.1/8” thru 1-1/8” capacity.
512
78
34
58
11 8
Tips for Flaring• An incorrect flare is one of the most common
sources of leaks. To help prevent leaks, cut tubing with a sharp wheel for a clean right angle cut. To avoid tube constriction, don’t feed the screw too fast.
• Since unremoved burrs can break off into the tubing or scratch the flared surface, remove burrs with a deburring tool.
• A flare tool with burnishing cone puts a high polish on the flare and rolls out a perfect 45° flare for a good seal. Over or under flaring prevents a good seal. Use a drop of oil on the flaring cone and feed screw for precise action.
83
Service Equipment
Sherlock Leak DetectorSherlock Low Temp leak detector is designed specifically for finding gas leaks at sub freezing temperatures. No mixing required.
BRUSH - TOP DISP
SHERLOCK LEAK DETECTOR
1 pt Bottle w/Brush Top Empty
1 gal Bulk Container
Teflon Tape
TT31202 1/2 X 520”TT31212 3/4 X 280”
Specially selected teflon tape is high density for excellent sealing on gas applications.
Pure Anhydrous MethanolPure anhydrous methanol is extremely effective in neutralizing moisture in propane storage containers. It has a high affinity for water and a boiling point lower than water.Available in 1 gal, 2-1/2 gal, 5 gal or 55 gal.
Pipe Joint Compound
PLS2 1/4 pt Gasoila 1/4 pt
Rectorseal #5 1/4 ptRectorseal #5 1/2 pt.
Rectorseal #100 1/4 ptRectorseal #100 1/2 pt.
Zoom Spout OilerHigh grade, light weight oil with retractable zoom spout to get into the tighest spots.
Gasoila is a blue/white, opaque, viscous, non-hardening, smooth paste with Teflon.
PLS2 is a gray, opaque, viscous, non-hardening, smooth paste with a high solids content.
Rectorseal #100 is a white, opaque, viscous, non-hardening, smooth paste with Teflon.
Rectorseal #5 is a slow dry, soft set, yellow paste for general piping service.
Gas Valve GreaseY70AA-1 Gas Valve Grease provides excellent lubricaton for gas valves from 32O to 175OF.2-1/2 oz tube
Y70AA-1
17-076
S HERLOC KLEAK
W I NTON PRODUC T S
DETECTOR
PLS 2
PIPETHREAD& GASKETSEALER
ONE QUARTER PINT
GASOILA
THREADSEALANTSOFT-SET
ONE QUARTER PINT
WITH TEFLON
"SERVING THE PROFESSIONAL SINCE 1937"
NET CONTENTS: 4 FL. OZ. (118 ML)
5SLOWDRY
CAUTION!COMBUSTIBLE AT 180OF SETA CC
SOFTSET
Pipe Thread Sealant
RECTORSEAL
100NON-
SEIZING
No.
Thread Sealing Paste with VIRGIN "TEFLON"
VIRGIN
NON-HARDENING
LOWFRICTION
Pipe Thread Sealant
RECTORSEAL
SPOUTZOOM
OILER
TF
E ThreadSeal Tape
Pure AnhydrousMethanol
341 GAS
VALVE
GREAS
E
84
Service Equipment
Safety Approved Flashlight
1259
HWC
Mine Safety and UL approved flashlight incorporates circuit breakers that separate a broken bulb from the battery source instantly. Eliminates the source of ignition from a glowing filament in a cracked or broken bulb.
Truck Wheel Chock Blocks
Railcar Chock Blocks Rail Sign Post
Heavy duty ribbed aluminum construction. Sold in pairs with 3 ft. connecting chain.LWC Light Wheel Chock for pickups and small service trucks.HWC Heavy Wheel Chock for bobtails and large service trucks.
Cast Steel blocks with heat treated spurs which bite into track to keep chocks from slipping. 25 lbs. shipping weight. Sold in pairs with 3 ft. chain.
Easy on, easy off sign post holds safety sign during railcar unloading.Sign not included.
23-173
Style “B” Chocks for Exposed Rail Underside View
Spurs
Model Description Width Length Height Weight
LWC Light Weight Chock 6” 7” 6” 10 lbs
HWC Heavy Weight Chock 7” 10-3/4” 8” 16 lbs
Edmont Seamless Monkey Grip GlovesRaised Finish Winter Monkey Grip gloves have a textured surface that provides an excellent grip for easier, safer handling of wet and dry materials. Tough, flexible vinyl coating provides a seamless surface to resist liquid penetration and abrasion. A soft, comfortable non-woven inner lining insulates against the cold.
23-171 Knitwrist fully coated large.23-173 Safety Cuff fully coated large.
23-171
Winter Tuf-Duk gloves are vinyl impregnated in two-tone brown and gold. The material repels liquid but the gloves are not liquid proof because of the seams. Provide excellent grip and long wear.
31-791 Driver’s Style large. 31-791
Edmont Tuf-Duk Gloves
STOPT A N K C A RCONNECTED
85
MasterKote Paint
Silicone Alkyd Enamel
Paint Cost
Highest Quality. The best choice for large storage tanks.You can’t beat silicone for resistance to weathering, especially ultra-violet light. It gives the pigments far better protection. Superior durability for large storage tanks. Outperforms standard enamels.
The cost of the paint is only about 25% of doing the paint job. With this in mind, it doesn’t make much sense to buy anything but a top quality paint. The price per gallon is not a reliable indicator of the total cost of painting. You should also consider the solids per gallon. (See the “What About Paint Coverage” inset).
QUALITY COATINGS SINCE 1955
PolyurethaneIndustrial Enamel
Master Products CompanyGoldsboro, N.C.
HIGH GLOSS
INDUSTRIALUSE ONLY
9001
R
Excellent durability. The best choice for domestic tanks.The toughness of the polyurethane film gives outstanding exterior durability and chemical resistance plus better gloss and fade resistance than standard enamels.
Polyurethane Enamel
Good durability. Good choice for domestic tanks.Formulated with durable alkyd resins and exterior grade pigments. The alkyd enamel provides high gloss that resists wear and weather with good one coat hiding.
Alkyd Enamel
High quality primer for all steel products.Heavy on the rust inhibitive additives makes this primer an exceptional first coat for all steel surfaces. Provides both barrier and great adhesion for the final paint coat.
Primer
Phenolic protection you can count on.Ringmaster phenolic is a must for cylinder bottom protection. It penetrates rust and coats the cylinder bottom and all the crevices around the footring for a hard, long lasting protective finish.
Ringmaster
QUALITY COATINGS SINCE 1955
Equipment andTank Enamel
Master Products CompanyGoldsboro, N.C.
ALUMINUM
INDUSTRIALUSE ONLY
351
R
QUALITY COATINGS SINCE 1955
SILICONE ALKYDGLOSS ENAMEL
Outstanding Gloss
Interior/ExteriorChecks Rust
Master Products CompanyGoldsboro, N.C.
and Color Retention
HEAVY DUTY
9010
R
9010 White
9001White9003 Aluminum9006 Trinity Gray4503 Yellow4703 Red
351 Aluminum
Ringmaster
7780 Primer
R
QUALITY COATINGS SINCE 1955
QUALITY COATINGS SINCE 1955
Black PhenolicPaint
Master Products Company
(Contains No Tar Or Asphalt)
Goldsboro, N.C.
RINGMASTER
INDUSTRIALUSE ONLY
R
RUST-OLEUMPREMIUM
OIL BASED ENAMEL
HIGH PERFORMANCE
INDUSTRIAL STRENGTH
PROFESSIONAL
Tough, rust preventitive finishfor industrial applications.
7780-402 PRIMER
WHEN YOUR COMPANY'S IMAGE MATTERSUSE MASTERKOTE
86
Painting Tools
BUCKETBONNET
MC-5 5 Gal Steel PailMG-5 Metal Bucket GridPCB-3 Bonnet (3 pk)
The 5 gallon bucket with a metal grid and bucket bonnet is a real easy system for daily tank painting.
The metal grid allows you to maintain an even paint load on the roller and keeps the drips in the bucket.
At the end of the day, simply hang the roller on the grid and cover the bucket with the bonnet.
PROAM-20 2” Brush
900-576 Roller Handle86M-9 Roller Cover
114-S Wire Brush w/Scraper
We are looking for at least 2 1/2 mils coverage for good steel protection.
What About Paint Coverage?
Keep it easy
1 GAL
.50 GAL
642 sq ft
1 1/4 mil thick231 cu in115.5 cu in
TOTALVOLUME
SOLIDSIN GALLON
COVERAGEPER COAT
= =
MASTERKOTE PAINT CONTAINS APPROXIMATELY 50% SOLIDS BY VOLUME
Use ONE gallon to apply two coats on a 1000 gal tank to get 2 1/2 mil protection.
Here's what happens when we roll the paint out.The 50% vehicle in thegallon evaporates.The 50% solids in the gallonspread out to a 1 1/4 milfilm covering 642 sq.ft.A second coat providesan additional 1 1/4 mils.Total coverage 2 1/2 mils.
TANK SIZEGALLONS
30,00018,00012,0001,000500325250120
2,0001,2001,000200100786238
8651
2 tanks2 tanks4 tanks7 tanks
APPROXSQ. FT.
GALLONSREQUIRED
The chart assumes that we are tryingto protect the tank with 2 1/2 mils ofthe finished coat. The numbers are based on Masterkote paint whichaverages 500 sq. ft. per gallon andrequires two coats for proper finish.Lesser quality paints will require morepaint to attain the same protection.
ASK ABOUT THE SOLIDS IN THE CAN!
87
Electrical Test Meters
DM383B
Full Function Digital MultimeterRead volts, amps, continuity with this high accuracy large display ruggedized meter.Includes digital multimeter with boot, 9v battery, 10A and 5A fuses, and rubberized test lead set.5 YR warranty.
Combustible Gas Leak Detectors
Electronic ManometerA digital, time saving alternative to U-tube pressure measurement.
Use to measure gas or draft pressures in light commercial and residential systems.
EM151
+LO BAT
In-Wg
Scale(Hold for OFF)
ZERO
EM151
DM383B DIGITAL MULTIMETER
MAX HOLD
!
A C A
A A VC O Mm A
D C A
D C VO H M S
D A T AM
H O L D
ACV
400m
400m40M4M
400K40K
4K
400
400m40m
4m
4
400
400
10A MAXFUSED 500mA
FUSED
CAT II 1000VCAT III 600V
10A10A 4A4A
4m
40m
400m
40
400
750
1000
40040
40
4
R
CombustibleGas Leak Detector
OFF
T I C A D J U S T
ON ALM
ALARM SET
READY
ALARM
CD200
R
SPECIFICATION CD100A CD200
Size 8” X 4” X 1-1/2” 8-3/4” X 3-1/4” X 2-1/2”
Flexible Probe 18” 18”
Sensitivity 50 ppm 50 ppm
Lighted Tip Yes Yes
Tic Adjustment Thumbwheel Thumbwheel
Tic Indicator Single Flashing LED Six graduated LEDs
Adjustable Alarm No Yes
Ear Phone Option Included
Carrying Case Option Included
Battery 9 volt 4 - AA
SPECIFICATION EM151
Range -20” to +20” W.C.
Accuracy +/- 1.0% FS
Battery Life 50 hours
Auto Power Off Yes
Warranty 1 Year
ON / OFF
TIC ADJ
TIC
LOW BAT PWR OFF
COMBUSIBLE GASLEAK DETECTORCD100
CD100A CD200
Pinpoints gas leaks fast and easy. LED and alarm indicators.
CONTROLBODY
10-038ADAPTER
TO MILLIVOLTMETER
Safety Magnet Test
Thermocouple TestingUse the DC Volts 400m range which provides a best resolution of 0.1 millivolt.Powerpile TestingUse the DC Volts 4v range which provides a best resolution of 1 millivolt.
Function Range
DC Volts
AC Volts
400mV, 4V, 40V, 400V, 1000V
400mV, 4V, 40V, 400V
50-500 Hz 750V
DC Current
400uA, 4mA, 40mA, 400mA
4A
10A
AC Current50-500 Hz
400uA, 4mA, 40mA, 400mA
4A
10A
Resistance
400 Ohm, 4K Ohm, 40K Ohm400K Ohm, 4M Ohm
40M Ohm
88
Signs
WE STOP AT ALL RR CROSSINGS
17042D 2” X 36” Vinyl
Filling Information SignsCYLINDER FILLINGCAPACITY CHART
2.39 4.78 7.17 9.5611.914.316.719.121.523.926.228.631.033.4
1 2 3 4 5 6 7 8 91011121314
35.8 38.2 40.6 43.0 45.4 47.8 59.7 71.7 78.8 83.6 95.6105.1119.5239
15 16 17 18 19 20 25 30 33 35 40 44 50100
WC WCLBS. PROPANE LBS. PROPANE
NOTICEFOR YOUR SAFETYWE ARE PROHIBITED FROM FILLING
CYLINDERS THAT ARE:
NOT APPROVED FOR LP-GAS.
OVER 12 YRS. OLD WITHOUT RE-CERTIFICATION &VISUAL RE-CERTIFICATION FOR EACH ADDITIONAL 5YEARS OF SERVICE.
DAMAGED, BURNED, OR BY VISUAL INSPECTION,APPEAR UNSAFE.NOT EQUIPPED WITH A COLLAR OR CAP TO PROTECTTHE VALVE WHILE IN TRANSIT.
FEDERAL & STATE REGULATIONS REQUIRE HAULINGPROPANE CYLINDERS SECURED IN A VERTICAL POSITION
NO SMOKING - NO OPEN FLAME
1.
2.
3.
4.
CAUTION!OPERATOR SHALL BE IN AT TENDANCE DURING ENTIRE FILLING OPERATION
RECOMMENDED PROCEDURE FOR FILLING MOTOR FUEL AND MOTOR HOME TANKS
1. Stop engine -- set parking brake -- chock wheels.2. Attach static ground to vehicle being filled.3. If motor home -- Turn off pilots -- close tank outlet valves.4. Connect fill hose to tank.5. Open storage tank valves.6. Open liquid level gauge -- (80% bleeder).7. Slowly open valve at end of hose.8. Start pump.9. Close hose end valve when liquid appears (white cloud) at liquid level gauge (80% bleeder).9b. If tank is equipped with 80% stop fill, propane will stop entering tank at this point.10. Stop pump.11. Close liquid level gauge (80% bleeder).12. Disconnect hose from tank after pressure between valve and tank is reduced to 0 pressure.13. Replace all protective caps.14. Close storage tank valves and lock system.
CAUTION!OPERATOR SHALL BE IN ATTENDANCE DURING ENTIRE FILLING OPERATION
RECOMMENDED FILLING PROCEDURE FOR PORTABLE CYLINDERS
1. Before starting filling procedure, check Tare Weight (T.W.) of cylinder empty and the Water Capacity (W.C.) of cylinder. Both are stamped on the cylinder collar.2. Determine the propane capacity from chart or multiply water capacity (W.C.) X .42.3. Add Tare Weight and propane capacity together to determine TOTAL FILLED WEIGHT of cylinder.4. Set scale to indicate Total Filled Weight, plus weight of hose and hose end valve.5. Open storage tank valves.6. Open valve on cylinder.7. Open valve on hose.8. Start pump.9. Close hose end valve as soon as scale beam raises or indicator tips.10. Stop pump.11. Close cylinder valve.12. Disconnect hose from cylinder.13. Check weight of filled cylinder after filling connector has been dis- connected. If overfilled, remove to a stand pipe or evacuation system and remove excess propane. NEVER LEAVE CYLINDER OVERFILLED14. Install POL PLUG and WARNING LABELS.15. Close storage tank valves.
P-101Cylinder Filling Chart
12” X 12” Poly
P-102Cylinder Conditions
12” X 12” Poly
P-108Motor Fuel Procedure
12” X 12” Poly
P-109Cylinder Procedure
12” X 12” Poly
S1279 Refilling Info DecalCovers in depth the procedures for filling cylinders and permanently mounted vehicle tanks. 11” X 17” Vinyl
C A U T I O N- CYLINDER -
MUST BE HAULEDIN UPRIGHT POSITION
Cyl 20 GACylinder Must Be Hauled
10” X 14” Steel
17042 5-1/2” X 20” Steel
CAUTIONTHIS VEHICLE MAKES FULL STOPSAT ALL RAILROAD CROSSINGS
1075D 11” x 11” Vinyl1075G 11” x 11” Magnetic1075P 11” x 11” Poly
10752
10752
CG-126 Flip Type Placard1075 - 1005
13.5” X 13.5” Aluminum
QT NQTV-66 3” X 6.5” VinylV-65 3” X 4.5” Vinyl
11223344K55667788T99000VPILV - External Visual Insp. I - Internal Visual Insp. P - Pressure Test
L - Lining Test K - Leakage Test T - Thickness Test
TYPE OF TEST PERFORMED AS ABOVE DATE
ANNUALINSP.
MO.
Test DateHM-183SECT. 180-415SECT. 108-417 11223344K
55667788T99000VPILV - External Visual Insp. I - Internal Visual Insp. P - Pressure Test
L - Lining Test K - Leakage Test T - Thickness Test
TYPE OF TEST PERFORMED AS ABOVE DATE
5 YEARINSP.
MO.
Retest DateHM-183SECT. 180-415SECT. 108-417
V-31 Annual 6” x 15.5” Vinyl V-32 Five Year 6” x 15.5” Vinyl
EMERGENCYSHUTOFF
V-134 2.5” X 6” Vinyl
10752
MPH69 Slide-inPlacard Holder
(Placard sold separately)
Vehicle Signs and Decals
89
Signs
FLAMMABLEGAS
2
LIQUIFIEDPETROLEUM
GASUN 1075
Goggles GlovesHZ 116
PROPANE
1
4
0
NFPA HAZARD RATING
HEALTHHAZARD
FIREHAZARD
REACTIVITY
CONSULT CORRESPONDING MSDS FOR
FURTHER INFORMATION AND INSTRUCTIONS.
4 --- Severe3 --- Serious2 --- Moderate
1 --- Slight0 --- Minimal
AFFIX TO ALL PORTABLE CONTAINERS USED BY COMMERCIAL CUSTOMERS
-- Extremely Flammable Gas-- Heavier than Air-- Simple Asphyxiant-- Odorized to warn of its presence-- Contact with Liquid will cause Freezing of Tissue-- P.E.L. 1000 PPM-- Store container outside and keep cool (under 1300F)-- Turn off container valve when not in use
PERSONAL PROTECTION
DANGER --FLAMMABLE GAS UNDER PRESSURE LEAKING LP-GAS CAN CAUSE A FIRE OR EXPLOSION IF IGNITED CONTACT
DO NOT USE OR STORE CYLINDER IN A BUILDING, GARAGE OR ENCLOSED AREA.LP-GAS SUPPLIERS FOR REPAIRS OR DISPOSAL OF THIS CYLINDER OR UNUSED LP-GAS FOR OUTDOOR USE ONLY*
Customer Warning: When Connecting for Use: Know the odor of LP-gas. Under certain circumstances, youmay not be able to smell the odorant. If you hear or smell leakingLP-gas, immediately get everyone away from the cylinder andcall the �re department.
Use only in compliance with applicable codes. Read and follow appliance manufacturer's instructions. If regulator has an internal threaded coupling nut and thecylinder valve has large outside threads, tighten the couplingnut by turning clockwise (TYPE 1-Figure 1).If regulator has a plug-in connection, pull valve sleeve back,insert male plug fully and release valve sleeve(TYPE 2-Figure 2). If the regulator has an external threadedcoupling nut, it has left-hand threads and must be tightenedby turning counter clockwise (POL TYPE-Figure 3).
Turn o� all valves on appliance. Do not check for gas leaks with a match or open �ame. Apply soapy water at areas marked "X" after openingcylinder valve. If bubbles appear, close valve and have anLP-gas service person make neede repairs. Also checkappliance valves and connections for leakage before lightingappliance. Light appliance(s) following manufacturer's instructions. When appliance(s) is not in use, keep cylinder valve closed.
DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL
EXCEPT AS AUTHORIZED BY NFPA 58 OR B 149.2 ((in Canada)
Caution your LP-gas supplier to:
LP-gas is heavier than air and can settle in low places whiledissipating. Contact with the liquid contents of the cylinder will cause freezeburns to the skin.
When the cylinder is not connected for use, keep the valveturned o�. If your cylinder valve looks like thePOL TYPE (Figure 3) and is of 45 lb. LP-Gas capacity or less,the outlet must also be plugged. Do not use, store or transport cylinder where it could be ex-posed to high temperatures. Relief valve can open allowing alarge amount of �ammable gas to escape. When transporting, keep cylinder secured in an upright positionwith cylinder valve turned o�. If the cylinder is of 45 lb. LP-Gascapacity or less and looks like the POL TYPE (Figure 3), theoutlet must also be plugged. Self-contained outdoor cooking appliances must be limited toone cylinder of 20 lbs LP-Gas capacity or less.
Do not allow children to tamper or play with the cylinder.
purge the cylinder of trapped air prior to �rst �llingcheck the cylinder requali�cation datebe certain not to over�ll the cylinder
TYPE 1(Figure 1)
PRESSURE RELIEF VALVEHANDWHEEL
HOSE
PLASTICCOUPLING
REGULATOR
PROPANE CYLINDER
X
X
X
X
X
X
X
VENTLIQUID LEVEL
INDICATOR(OPTIONAL)
ACMETHREADS
TYPE 2(Figure 2)
PRESSURE RELIEF VALVEHANDWHEEL
SPRING-LOADEDSLEEVE
HOSE
REGULATOR
PROPANE CYLINDER
X
X
X
X
XX
X
VENTLIQUID LEVEL
INDICATOR(OPTIONAL)
POL TYPE(Figure 3)
PRESSURE RELIEF VALVEHANDWHEEL
HOSE
REGULATOR
PROPANE CYLINDER
X
X
X
X
XX
X
VENTLIQUID LEVELINDICATOR
(OPTIONAL)*
SDOTDOT Compliance
1.25” x 3.75” Vinyl
CYL 2 in 1DOT & Duty to Warn
3” x 7” Vinyl
SP-53RDuty to Warn3” x 7” Vinyl
HZ-116OSHA Compliance
2.2” x 5” Vinyl
DANGER-FLAMMABLE GAS UNDER PRESSURE LEAKING LP-GAS CAN CAUSE A FIRE OR EXPLOSION
IF IGNITE
D CONTAC
TLP-GAS SUPPLIERS FORREPAIRS OR DISPOSAL OFTHIS CYLINDEROR UNUSED LP-GASFOROUTD
OORUSE
ONLY*
DONOTUSE ORSTORE CYLINDER IN A BUILDING, GARAGE OR ENCLOSED AREA.
CustomerWarning:
CustomerWarning:
FLAMMABLE
GAS
2
TYPE 1(Figure 1)
TYPE 2(Figure 2)
POLTYPE(Figure 3)
*
Cylinder Stickers
DANGER --FLAMMABLE GAS UNDER PRESSURE LEAKING LP-GAS CAN CAUSE A FIRE OR EXPLOSION IF IGNITED CONTACT
DO NOT USE OR STORE CYLINDER IN A BUILDING, GARAGE OR ENCLOSED AREA.LP-GAS SUPPLIERS FOR REPAIRS OR DISPOSAL OF THIS CYLINDER OR UNUSED LP-GAS FOR OUTDOOR USE ONLY*
Customer Warning: When Connecting for Use: Know the odor of LP-gas. Under certain circumstances, youmay not be able to smell the odorant. If you hear or smell leakingLP-gas, immediately get everyone away from the cylinder andcall the �re department.
Use only in compliance with applicable codes. Read and follow appliance manufacturer's instructions. If regulator has an internal threaded coupling nut and thecylinder valve has large outside threads, tighten the couplingnut by turning clockwise (TYPE 1-Figure 1).If regulator has a plug-in connection, pull valve sleeve back,insert male plug fully and release valve sleeve(TYPE 2-Figure 2). If the regulator has an external threadedcoupling nut, it has left-hand threads and must be tightenedby turning counter clockwise (POL TYPE-Figure 3).
Turn o� all valves on appliance. Do not check for gas leaks with a match or open �ame. Apply soapy water at areas marked "X" after openingcylinder valve. If bubbles appear, close valve and have anLP-gas service person make neede repairs. Also checkappliance valves and connections for leakage before lightingappliance.
Light appliance(s) following manufacturer's instructions. When appliance(s) is not in use, keep cylinder valve closed.
DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABELEXCEPT AS AUTHORIZED BY NFPA 58 OR B 149.2 ((in Canada)
Caution your LP-gas supplier to:
LP-gas is heavier than air and can settle in low places whiledissipating. Contact with the liquid contents of the cylinder will cause freezeburns to the skin.
When the cylinder is not connected for use, keep the valveturned o�. If your cylinder valve looks like thePOL TYPE (Figure 3) and is of 45 lb. LP-Gas capacity or less,the outlet must also be plugged. Do not use, store or transport cylinder where it could be ex-posed to high temperatures. Relief valve can open allowing alarge amount of �ammable gas to escape. When transporting, keep cylinder secured in an upright positionwith cylinder valve turned o�. If the cylinder is of 45 lb. LP-Gascapacity or less and looks like the POL TYPE (Figure 3), theoutlet must also be plugged. Self-contained outdoor cooking appliances must be limited toone cylinder of 20 lbs LP-Gas capacity or less.
Do not allow children to tamper or play with the cylinder.
purge the cylinder of trapped air prior to �rst �llingcheck the cylinder requali�cation datebe certain not to over�ll the cylinder
TYPE 1(Figure 1)
PRESSURE RELIEF VALVEHANDWHEEL
HOSE
PLASTICCOUPLING
REGULATOR
PROPANE CYLINDER
X
X
X
X
X
X
X
VENTLIQUID LEVEL
INDICATOR(OPTIONAL)
ACMETHREADS
TYPE 2(Figure 2)
PRESSURE RELIEF VALVEHANDWHEEL
SPRING-LOADEDSLEEVE
HOSE
REGULATOR
PROPANE CYLINDER
X
X
X
X
XX
X
VENTLIQUID LEVEL
INDICATOR(OPTIONAL)
POL TYPE(Figure 3)
PRESSURE RELIEF VALVEHANDWHEEL
HOSE
REGULATOR
PROPANE CYLINDER
X
X
X
X
XX
X
VENTLIQUID LEVELINDICATOR
(OPTIONAL)
*
Goggles Gloves
PROPANE
1
4
0
NFPA HAZARD RATING
HEALTHHAZARD
FIREHAZARD
REACTIVITY
CONSULT CORRESPONDING MSDS FORFURTHER INFORMATION AND INSTRUCTIONS.
4 --- Severe3 --- Serious2 --- Moderate
1 --- Slight0 --- Minimal
AFFIX TO ALL PORTABLE CONTAINERS USED BY COMMERCIAL CUSTOMERS
THIS LP TANK IS EQUIPPEDWITH A SAFETY RELIEF VALVE.
DO NOT PLACE INSIDE ANYENCLOSED OR HEATED AREA
-- Extremely Flammable Gas-- Heavier than Air-- Simple Asphyxiant-- Odorized to warn of its presence-- Contact with Liquid will cause Freezing of Tissue-- P.E.L. 1000 PPM-- Store container outside and keep cool (under 1300F)-- Turn o� container valve when not in use
PERSONAL PROTECTION
LIQUIFIEDPETROLEUM
GASUN 1075
FLAMMABLEGAS
2
CYL 3 in 1DOT
Duty to WarnOSHA
4.75” x 6.5” Vinyl
010203
010203
010203
010203
010203
010203
010203
010203
QTR. 1
5-V88-1
040506
040506
040506
040506
040506
040506
040506
040506
QTR. 2
5-V88-2
070809
070809
070809
070809
070809
070809
070809
070809
QTR. 3
5-V88-3
101112
101112
101112
101112
101112
101112
101112
101112
QTR. 4
5-V88-4
5-V88-1
5-V88-3
5-V88-2
5-V88-4
CAUTION
This container is NOTequipped with an OPD(over�lling prevention device)
V-128NO OPD Sticker
Use for cylinders thatcannot be upgrade tothe new OPD valve
4.75” x 4” Vinyl
This tank has beenvisually reinspected in accordance
with 49 CFR 180.209(g)
Visual Requali�erIdenti�cation Number
Date/TypeVisual Inspection/04 E
5-C86
Your RINpreprinted here
Peel & stickmonth here
C-583” x 1.875” Vinyl
Cylinder Requalification Stickers
90
N O T I C EAUTHORIZED PERSONNEL
ONLY
S1317VAuthorized Personnel
10” X 14” Steel
Plant Signs
CAUTIONBURIEDGASLINE
EMERGENCYSHUTOFF VALVEPULL TO CLOSE
LIQUIDLIQUIDLIQUIDLIQUIDLIQUID
VAPORVAPORVAPORVAPORVAPOR
P-81 10” x 12” Poly
P-148 12” x 12” Poly P-149 12” x 12” Poly
LP-1 4” x 5”Yellow Flag21” Wire StaffMarks Existing Lines
LP-5 4” x 5”White Flag21” Wire StaffMarks Proposed Lines
V-90-5 Five Ea1” x 4” Vinyl
V-91-5 Five Ea1” x 4” Vinyl
140
HZ-704-1 7.5” X 7.5” VinylHZ-704-3 15” X 15” Vinyl
FLAMMABLEV-24BB 4” X 22” Vinyl
LIQUEFIED PETROLEUM GAS
V-302BB 4” X 36” Vinyl
NO SMOKING916D 2” Letters Vinyl (3” X 14”)916D-3 3” Letters Vinyl 4” X 22”)
PROPANE155-71D 2” Letters Vinyl (3” X 12”)155-714D 4” Letters Vinyl (5” X 18”)155-716D 6” Letters Vinyl (6.75” X 27”)
DANGERN O S M O K I N GM AT C H E S O RO P E N L I G H T S
NO TRESPASSING
157 10” X 14” Steel157D 10” X 14” Vinyl201 14” X 20” Steel
949 4” X 24” Steel
EMERGENCYSHUTOFF VALVEPUSH TO CLOSE
P-82 10” x 12” Poly
C A U T I O N- SHUT OFF -
ENGINE BEFOREREFUELING
2929-9 20GAShut Off Engine14” X 20” Steel
PROPANE-CONTAINERLIQUID VALVE
EMERGENCY SHUTOFFPULL TO CLOSE
PROPANE-CONTAINERLIQUID VALVE
EMERGENCY SHUTOFFPUSH TO CLOSE
STOPT A N K C A RCONNECTED
945BTank Car Sign
11” X 17” Steel(Shown with
accessory rail sign post)
91
Reels
Hannay Hose ReelsHannay LP-Gas hose reels are of heavy duty construction and are de-signed for operating pressures of 1,000 PSI. Complete units are built to order from individual components matched to the hose capacity, piping size, mounting arrangement and rewind direction required.Many different configurations are available to suit individual needs. The most common arrangement with top right rewind, 12v DC explosion proof motor, manual rewind and 1-1/2” connections is shown.
Add convenience and ease of hose handling with the FH3 roller and spool assembly. Especially helpful for odd angle hose reeling.
For the ultimate ease in hose handling, use the Guide-master hose guide.
Typical EPBHose Reel
Common Models and Dimensions
FH3 Roller & Spool Assembly Guidemaster
FH3Shown with top wind brackets
GuidematerShown with bottom wind brackets
A D
F
F
ReelModelNumber
1” I.D. HoseCapacity
(Feet)
Reel Dimensions (inches)
A B C D E F G Ship Wt. (lbs.)
EPB24-23-24 125 21 15.5 10.5 20.5 22.75 29.25 23.5 144
EPB30-23-24 150 27.5 22 10.5 20.5 22.75 33.75 23.5 157
EPB24-25-26 150 21 21 10.5 25.5 24.75 29.25 27.88 152
B E
C
92
Reels
Common Replacement Parts
12v DC XP Motors
Brake/RewindAssembly
Motor Sprockets
Chain
9915.0003 1/2 HP 650 RPM9915.0009 2/3 HP 500 RPM
9914.0200
9910.1117 #35 chain 11 tooth 1-11/16” long9910.0917 #40 chain 9 tooth 1-5/16” long
9912.0001 #35 chain 10 ft. long9912.0002 #40 chain 10 ft. long
Front Bearing 1-1/2”
Back Bearing 1”
Bevel Gears9914.0372 Ring Gear9914..0394 Pinion Gear
H-150G Riser Gasket
Chain Pitch Size
ChainPitch
A Roller Width
B Link Spacing
#35 27.5 22
#40 21 21
AB
XP SwitchEPS-1
Rectangular SwitchEXPB-2A
Junction BoxJBC
12v Solenoid9917.0025
Circuit Breaker9917.0021 50 Amp9917.0027 70 AmpSwitch Bracket
ESH-2A
93
Chiksan Swivel Joints
ChiksanPackingFor Swivel Joints
Chiksan swivel joints are high performance malleable iron units for 1,000 PSI service. All swivels are equipped with -175OF “AD” stainless steel, spring loaded teflon packing.Unsurpassed for long, leak-free service under the extreme temperature conditions experienced in liquid propane service.Stock Sizes:3/4” thru 2” FNPT
#7 Grease14-1/2 oz tube-50 - 212 OF
“AD” Packing Sets3178521 3/4” - 1”3178528 1-1/4” - 1-1/2”3178535 2”
Ball Bearing Sets1/4-40 3/4” - 1”1/4-54 1-1/4” - 1-1/2”3/8-48 2”
“AD” Packing Set
NO. 7LUBRICANT
CHIKSAN
FH-3Roller and Spool Assembly
FH-3 Roller Length Indetification
FH-3 Roller Part Numbers
Roller NumberRoller Length
w/bushingsA (inches)
Mounting BoltsC to C
B (inches)
9940-010(specify length)
16 18.75
18 20.75
20.5 23.25
22.5 25.25
24.5 27.25
26.5 29.25
Key # Part Number Description
1 9940.0010 Roller Tubing (specify length)
2 9940.0009 Roller Rod (specify length)
3 9940.0008 Trunion Bearing
4 9940.0002 Black Cap (replaces obs. chrome cap)
5 9940.0012 Plastic-coated Step Bolt w/washers & Nut
6 9940.0005 Chrome Spool
7 9940.0006 Chrome Block
“A”“B”
FH3 Roller Identification
FH3 Roller Parts
1
2
3
4
5
6
7
Reels