firescan d131 - quick reference
TRANSCRIPT
-
8/11/2019 FireScan D131 - Quick Reference
1/23
-
8/11/2019 FireScan D131 - Quick Reference
2/23
-
8/11/2019 FireScan D131 - Quick Reference
3/23
After configuring the scanner, read one of the following codesto set desired aiming system timeout.
aiming system disabled
300 ms
500 ms
1 sec
-
8/11/2019 FireScan D131 - Quick Reference
4/23
CONNECTIONS
RS232
With the RS232 cable, this accessory device is intended to besupplied by a UL Listed Direct Plug-in Power Unit marked"Class 2", rated 5 V, minimum 200 mA.
USB
With the USB cable, this accessory device is intended to besupplied by a UL Listed Power Unit marked "Class 2", or anLPS power source which supplies power directly to the reader.
IBM USB POS
With the USB cable, this accessory device is intended to beconnected to a UL Listed computer which supplies powerdirectly to the reader.
(if required)
-
8/11/2019 FireScan D131 - Quick Reference
5/23
PEN
With the Pen Emulation cable, this accessory device isintended to be supplied by a UL Listed Power Unit marked"Class 2", or an LPS power source which supplies powerdirectly to the reader.
WEDGE
With the Wedge or PC Notebook cables, this accessory deviceis intended to be connected to either a UL Listed Computerwhich supplies power directly to the reader or a UL ListedDirect Plug-in Power Unit marked Class 2, rated 5 V,
minimum 200 mA.
-
8/11/2019 FireScan D131 - Quick Reference
6/23
DISCONNECTING THE CABLE
READING DIAGRAM
100 200 400
200
100
0
-100
-200
300 500 600
Reading Zones (10 skew angle)
700 800 mm
-300mm
300
1.00mm
0.12mm
0.19mm
0.25
mm
EAN0.33 mm
0.38
mm
0.50mm
-
8/11/2019 FireScan D131 - Quick Reference
7/23
-
8/11/2019 FireScan D131 - Quick Reference
8/23
-
8/11/2019 FireScan D131 - Quick Reference
9/23
Connect FireScanto Host
Does a dialogbox appear
warning that Buspower is notsufficient?
Select desired USBinterface code
(USB-KBD is default)
Disconnect readerat Host
Connect externalpower supply to
cable and power up
Reconnect readercable to Host andclose dialog box
NO
YES
Read test codes.Reader is READY
Load drivers(if requested)
Load drivers(if requested)
Green LED blinks
Green LED off - BEEP OK
BEEP OK
First Start-Up
Green LED off
Successive start-ups will automatically recognize the previouslyloaded drivers. If external power is used, verify that externalpower is already supplied.
NO
YES
Read test codes.Reader is READY
Green LED blinks
Green LED off - BEEP OK
BEEP OK
Connect FireScanto Host
Successive Start-Ups
Disconnect readerat Host
Connect externalpower supply to
cable and power up
Reconnect readercable to Host andclose dialog box
Does a dialog boxappear warning
that Bus power isnot sufficient?
-
8/11/2019 FireScan D131 - Quick Reference
10/23
USB INTERFACE SELECTION
USB-KBD
USB-COM*
USB-IBM-Table Top
USB-IBM-Hand Held
USB-KBD-ALT-MODE
USB-KBD-APPLE
* When configuring USB-COM, the relevant files and driversmust be installed from the USB Device Installation softwarewhich can be downloaded from the web pagehttp://www.datalogic.com/services/support/.
-
8/11/2019 FireScan D131 - Quick Reference
11/23
USB KEYBOARD NATIONALITY
USB-KBD users should select one of the following KEYBOARDNATIONALITY codes. The default value is restored through theInterface Selection code.
Belge
Deutsch
English
Espaol
Franais
Italiano
Svenskt
-
8/11/2019 FireScan D131 - Quick Reference
12/23
USB KEYBOARD NATIONALITY (Continued)
USA
Japanese
RS232 READER CONFIGURATION
Read the RESTORE DEFAULT code, then read the interfaceselection code for your application.
RESTORE DEFAULT
RS232
Standard
POS Systems
Nixdorf Mode A
Fujitsu
ICL Mode
-
8/11/2019 FireScan D131 - Quick Reference
13/23
WEDGE READER CONFIGURATION
Read the RESTORE DEFAULT code, then read the interfaceselection code for your application.
RESTORE DEFAULT
WEDGE
IBM AT or PS/2 PCs
IBM XT
PC Notebook
IBM SURE1
IBM Terminal 3153
-
8/11/2019 FireScan D131 - Quick Reference
14/23
WEDGE (continued)
IBM Terminals 31xx, 32xx, 34xx, 37xx:
To select the interface for these IBM Terminals, read thecorrect KEY TRANSMISSION code. Select theKEYBOARD TYPE if necessary (default = advanced
keyboard).KEY TRANSMISSION MODE
make-only keyboard
make-break keyboard
KEYBOARD TYPE
advanced keyboard
typewriter keyboard
The following interface selection allows barcodes sent tothe PC to be interpreted correctly independently from theKeyboard Nationality used. You do not need to make aKeyboard Nationality selection.
(default = Num Lock Unchanged)Make sure the Num Lock key on your keyboard is ON.
IBM AT - ALT mode
PC Notebook - ALT mode
-
8/11/2019 FireScan D131 - Quick Reference
15/23
WEDGE (continued)
Wyse Terminals
ANSI Keyboard
PC Keyboard
ASCII Keyboard
VT220 style Keyboard
Digital Terminals
VT2xx/VT3xx/VT4xx
APPLE
APPLE ADB Bus
-
8/11/2019 FireScan D131 - Quick Reference
16/23
WEDGE KEYBOARD NATIONALITY
Wedge users should select one of the following WEDGEKEYBOARD NATIONALITY codes. The default value isrestored through the Interface Selection code.
Belge
Deutsch
English
Espaol
Franais
Italiano
Svenskt
USA
The following Keyboard Nationality selection is only valid forIBM AT compatible PCs:
Japanese
-
8/11/2019 FireScan D131 - Quick Reference
17/23
-
8/11/2019 FireScan D131 - Quick Reference
18/23
-
8/11/2019 FireScan D131 - Quick Reference
19/23
CODE SELECTION
enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ONcheck digit transmitted, no conversions
Interleaved 2/5check digit control and transmission, variable length
code; 4-99 characters
Standard Code 39no check digit control, variable length code; 1-99characters
Code 128variable length code; 1-99 characters
disabled codes:
EAN 128, ISBT128, Code 93, Codabar, pharmaceuticalcodes, MSI, Plessey, Telepen, Delta IBM, Code 11,Code 16K, Code 49, RSS Codes
ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined
-
8/11/2019 FireScan D131 - Quick Reference
20/23
OPERATING TEST
Read the TEST codes below.
EAN-8
1 2 3 4 5 6 7 0
EAN-13
1 2 3 4 5 6 7 0 0 0 9 9 2
Code 39 (Normal)
1 7 1 6 2
Code 128
t e s t
Interleaved 2 of 5
0 1 2 3 4 5 6 7 8 4
YOUR READER IS NOW READY TO READ BARCODES.To change the defaults see the HHD II Software ConfigurationManual, part number 90ACC1877.
-
8/11/2019 FireScan D131 - Quick Reference
21/23
WARRANTY
Datalogic warranties this product against defects inworkmanship and materials, for a period of 24 months from thedate of shipment, provided that the product is operated undernormal and proper conditions.
Datalogic has the faculty to repair or replace the product, theseprovisions do not prolong the original warranty term.
The warranty does not apply to any product that has beensubject to misuse, accidental damage, unauthorized repair ortampering.
SERVICES AND SUPPORT
Datalogic provides several services as well as technical supportthrough its website. Log on to www.datalogic.com/servicesand click on the links indicated for further information including:
Datalogic Services Warranty Extensions andMaintenance Agreements
Downloads Software Downloads, Manuals andCatalogues
Contact Us Listing of Datalogic Subsidiaries andQuality Partners
Authorised Repair Centres
Products >Hand-Held Readers >Software Tools DL Sm@rtSet
DL Sm@rtSet is a Windows-based utility program whichallows device configuration using a PC. It provides RS232
interface configuration as well as configuration barcodeprinting.
FCC COMPLIANCE
-
8/11/2019 FireScan D131 - Quick Reference
22/23
FCC COMPLIANCE
This device complies with PART 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference whichmay cause undesired operation.
This equipment has been tested and found to comply with thelimits for a Class A digital device, pursuant to part 15 of theFCC Rules. These limits are designed to provide reasonableprotection against harmful interference when the equipment isoperated in a commercial environment. This equipmentgenerates, uses, and can radiate radio frequency energy and, ifnot installed and used in accordance with the instruction
manual, may cause harmful interference to radiocommunications. Operation of this equipment in a residentialarea is likely to cause harmful interference in which case theuser will be required to correct the interference at his ownexpense.
-
8/11/2019 FireScan D131 - Quick Reference
23/23