UP
DN
FIRE PROTECTION NOTES:1) All work to comply with Act 103 of 1977 and SANS 10400 Part T-2011.2) Occupancy Classification: __A1____ as per SANS 10400-A clause 20.3) 1 x 4,5 kg Extinguisher per 200m² or part thereof, to be installed in accordance with SANS 10105 and clause 4.384) Existing fire services to be extended to comply with SANS 10400 - 2011 Part W.5) Portable fire extinguishers (FE) to be hung on purpose made boards as indicated on plan.6) Heat Detectors - point detectors, to be installed as indicated on plan and to comply with SANS 50054/EN 54-5 Fire detection and fire alarm systems Part 57) Smoke Detectors - point detectors using transmitted light, to be installed as indicated on plan, and to comply with SANS 50054/EN 54-7 Fire detection and fire alarm systems Part 78) New or Existing Automatic Sprinkler systems to be installed or maintained to comply with SANS 10400-T and SANS 10287 for fire fighting purposes9) Doors in escape routes may only be fitted with approved locking devices and shall not be lockable as per clause 4.18.10) Doors in feeder routes shall be double swing type and shall not be locakble as per clause 4.18.11) Exit doors may only be fitted with panic bars complying witn EN1125 as per clause 4.16.10 (All 'A' occupancy population > 60)12) Floor coverings to be as per clause 4.14.13) Wall coverings to be as per clause 4.15.14) Emergency lighting to be installed and designed in accordance with SANS 10400 - Part -T and SANS 10114-2.15) A manually activated audible and visual alarm in accordance with SANS10139 to be installed as per clause 4.31.16) Fire detection and emergency evacuation communication system, complying with SANS 10139 to be installed as per clause 4.31.17) Illumination symbolic safety signs to be installed above all exist doors, as per clause 4.29.18) Photoluminescent escape signs to be provided and to comply with SANS 1186 Part 1 and 5, as per clause 4.29.19) Photoluminescent symbolic signs indicating fire equipment to be provided and to comply with SANS 1186 Part 1 and 5, as per clause 4.32.20) Suspended ceilings and supporting members shall be of non-combustible material.21) Fire walls will extend to the underside of the roof covering and no combustible roof elements will penetrate such.22) No dangerous goods will be stored in excess of the exempt qualities as per SANS10263 - 0 Annex 'A'.23) All Dry Walls and Partitions to comply with SANS 08224) Ventilation to comply with SANS 10400 - Section 4.42
1800 2355 1800 1800 1780 1800 1800 1784 1821 900 1771
2400
1829
1875
1340
1340
1332
1995 2310
1822
1822
20682067
22332160 1800
1898
1471
1822
1800
1826
18243109
45930
500
9398
55828
22054 115 5119
27288
30725
13635 4440 12280
Client
Project Title
Drawing Title
Plot
Job No.
Designed
Scale
Drawing No.
CheckedDrawn
Date Client approval
* All building work to comply with SABS 0400* No dimensions to be scaled or scanned from drawing* All dimensions to be checked on site* Where applicable the contractor is to check on site size of components to be manufactured prior to manufacture* Contractor is responsible for correct setting out of the buildings, all external and internal walls with particular reference to boundaries, building lines, etc.* Contractor to verify all levels, heights and dimensions on site and to check the same against the drawings before putting any work in hand* Contractor is to locate and identify existing services on the site and to protect these from damage throughout the duration of the works* Any errors, discrepancies or omissions to be reported immediately.* Contractor is to build in approved 4 ply D.P.C. weather or not these are shown on drawings, to all walls at each floor, beam or parapet level and to all windows, doors, grilles or other openings in external walls.* Any queries arising from all the above must be reported and clarified before any works are put in hand.* This drawing is not to be scaled, figured dimensions are to used at all times.
* All plumbing and drainage work and installation of sanitary fittings to comply with the relevant local authority by-laws, regulations and requirements.* Provide I.E.'s to all bends and junctions with suitable markers at ground level and to be fully accessible at all times.* Minimum 1:60 fall to all drain pipes.* Provide approved reseal traps to all waste fittings* Provide A.E.'s to foot of all soil stacks.* All soil pipes passing under buildings or footings to be protected against loads.
BRAND DNA cc is the proprietor of all rights including copyrights in thismaterial.No reproductions are permitted without written consent.The client accepts the responsibility of materials, content and statement.The elements shown on this drawing are prototypical design only, Theymay not be utilized or altered, the specification changed or implemented inpart or whole in any structure without notification and written approvalfrom BRAND DNA cc.
GENERAL NOTES:
PLUMBING NOTES:
COPYRIGHT:
REVISIONS:
No. Date Description Int.
Unit 35, Frost Street Lofts, Frost Avenue,
Braamfontein Werf, 2092,
Johannesburg, South Africa.
Tel: +27(0)87 702 9550
Registration number: PAT 20585
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
As indicated
CRAZY PLASTICS
FIRE SAFETY PLAN
CRAZY PLASTICS SOMERSET WEST
12/04/2019 Approver
A.MORIARTY BZBRAND DNA
CRA-PLA-SSW CPS-206F
FIRE SCHEDULE
SYMBOL DESCRIPTION QTY
FIRE ESCAPE ROUTE 156
SIGN TO WALL - DIRECTIONTO ESCAPE ROUTE
3
SIGN TO WALL (GREEN)ESCAPE ROUTE ARROW
3
SIGN TO WALL - LOCATIONOF FIRE EXTINGUISHER
7
SIGN TO WALL (RED) -LOCATION OF FIRE FIGHTINGEQUIPMENT ARROW
7
FIRE EXIT KEEP CLEARPhotoluminance sign (glow inthe dark)
3
NEW FIRE HOSE REEL 3
1 : 125
FIRE SAFETY PLAN
06/03/2018 SKETCH PLAN ISSUED
F 12/04/2019 REVISED WORKING DRAWINGS ISSUED