fire extinguisher redesign
DESCRIPTION
Fire Extinguisher Redesign. Maddie Burke Design Project Management Student Initiated Projects: R12900 Spring 2011-2012. Functional Timeline. INDICATORS SHOW ‘READY TO USE’. INDICATORS CHANGE TO ‘USED’. RELEASES WATER. REFILL CYLINDER WITH WATER. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/1.jpg)
Fire Extinguisher RedesignMaddie Burke
Design Project ManagementStudent Initiated Projects: R12900
Spring 2011-2012
![Page 2: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/2.jpg)
Functional Timeline
FIRE REMOVE EXTINGUISHER
REMOVES SAFETY PIN
ALARM ON BOX GOES OFF
PRESS TRIGGER
ACTUATES VALVE
RELEASES WATER
REMOVE CYLINDER
REFILL CYLINDER WITH WATER
RELOAD EXTINGUISHER
BOX AUTOMATICALLY PRESSURIZES
CYLINDER OF H20
INDICATORS SHOW ‘READY TO USE’
RELOAD EXTINGUISHER INTO
BOX
INDICATORS CHANGE TO ‘USED’
![Page 3: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/3.jpg)
Functional Flow DecompositionEXTINGUISH
RELOAD
TRIGGER SPRAY FORCE
EXTINGUISHER INTO BOX
REMOVE FROM BOX
REMOVES SAFETY
CHANGES INDICATORS
CONVERT FORCE TO OPEN VALVE
SPRAYS OUT WATER
RESET INDICATORS
EMPTY H2O CYLINDER
REPRESSURIZE WATER
RELOAD SAFETY
RELOADED EXTINGUISHER
WATER INTO CYLINDER
CYLINDER INTO EXTINGUISHER
![Page 4: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/4.jpg)
Fire Extinguishers• Materials• Spray time• Size• Weight• Price• Rating• Water amount• Spray range
Benchmarks: Fire Extinguishers
Constraints• Under 15 lbs• 2.5 gallons of
water• Rechargeable • Cost to design
![Page 5: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/5.jpg)
Benchmarks: Intentionally Intuitive Devices
![Page 6: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/6.jpg)
Metrics and Specifications
![Page 7: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/7.jpg)
Difficulty of Metrics and Specifications
![Page 8: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/8.jpg)
House of Quality Cross Linking• every customer need
is met by some engineering specification
• Some x-ed off as “related” if not directly dependent on one another
![Page 9: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/9.jpg)
Suggested Staffing Requirements
![Page 10: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/10.jpg)
Project Scope Feedback• Staffing: industrial design student would bring a
unique set of skills to the design• Safety: there will have to be some sort of testing box
in case of explosion of the pressurized vessel during tests
• Specifications: intuitive design aspects will be hard to quantify, a wide range of user testing will be needed
• Scope: project would include extinguisher design and box design, could be split into different jobs (as shown in the staffing slide) so multiple things can be worked on at once
![Page 11: Fire Extinguisher Redesign](https://reader035.vdocuments.mx/reader035/viewer/2022062218/56816739550346895ddbeb1b/html5/thumbnails/11.jpg)
QUESTIONS?