fire and life safety: notification and emergency communication systems
DESCRIPTION
Every facility has inherent and unique risks, which introduce emergency communication design challenges. Understanding emergency communication system design, installation, and maintenance criteria requires engineers to be familiar with the applicable codes and standards, primarily NFPA 72: National Fire Alarm and Signaling Code. Whether designing to provide emergency communication for fire or mass notification emergencies, NFPA 72 can be used as a tool to enhance the design, installation, and reliability of fire alarm systems used for emergency communications.TRANSCRIPT
![Page 1: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/1.jpg)
Fire and Life Safety: Notification and Emergency
Communication Systems
![Page 2: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/2.jpg)
1. The audience will understand applicable sections of the 2013 edition of NFPA 72: National Fire Alarm and Signaling Code.
2. Attendees will learn the design criteria for emergency communications systems (ECS).
3. Viewers will understand the factors required to be considered when designing mass notification systems (MNS), a subset of emergency notification.
4. Viewers will learn how to apply (and subsequently specify) available notification technologies in ECS and MNS applications.
Learning Objectives
![Page 3: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/3.jpg)
Ray Grill, PE, FSFPE, LEED AP, Arup, Washington, D.C.
Moderator: Jack Smith, Consulting-Specifying Engineer and CFE Media, LLC
Presenters:
![Page 4: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/4.jpg)
Sponsored by:
Fire and Life Safety: Notification and Emergency
Communication Systems
Ray Grill, PE, FSFPE, LEED APPrincipal
Arup
![Page 5: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/5.jpg)
Agenda
• ECS in the context of NFPA 72• Overview of NFPA 72 requirement for
designing ECS and risk analysis required• Key considerations for the analysis• Design features driven by the risk analysis• NFPA 72 requirements for notification
appliances
![Page 6: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/6.jpg)
Chapter 24 – Emergency Communications
![Page 7: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/7.jpg)
Systems Addressed
• 24.4 One-way ECS– 24.4.2 In-building Fire EVACS– 24.4.3 In-building MNS– 24.4.4 Wide-area MNS– 24.4.5 Distributed Recipient MNS
• 24.5 Two-way ECS– 24.5.1 Two-way in-building wired– 24.5.2 Two-way radio enhancement– 24.5.3 Area of refuge ECS– 24.5.4 Elevator ECS
![Page 8: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/8.jpg)
Why Risk Analysis in NFPA 72?
• Incorporated into the Scope for ECS TC• Recognizes that emergency
communications need to be designed to be:– Specific to the facilities and hazards– Coordinated with the emergency response plan
• Prescriptive requirements can not address all situations
![Page 9: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/9.jpg)
What is a risk analysis?
• In the context of NFPA 72:
– 3.3.246 Risk Analysis. A process to characterize the likelihood, vulnerability, and magnitude of incidents associated with natural, technological, and manmade disasters and other emergencies that address scenarios of concern, their probability, and their potential consequences.
![Page 10: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/10.jpg)
Risk Analysis vs. Emergency Response Plan
NFPA 72 Definition
• 3.3.93 Emergency Response Plan. A documented set of actions to address response to natural, technological, and man-made disasters and other emergencies prepared by the stakeholders from information obtained during the risk analysis.
![Page 11: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/11.jpg)
New to the 2013 Edition
![Page 12: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/12.jpg)
When is a Risk Analysis Required?
• When other signals need to take priority over fire
![Page 13: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/13.jpg)
When is a Risk Analysis Required?
• Determination of pathway survivability for ECS circuits when not specifically defined in NFPA 72– MNS circuits may have a different level of survivability
than circuits required for fire emergencies
24.3 ECS – General Requirements
![Page 14: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/14.jpg)
2016 Proposed Change to Survivability for Fire EVAC
• Two new exceptions– Level 1 survivability shall be permitted if
the building construction is less than 2 hour rated
– Circuits required to be survivable are Class X and the runs are separated by at least 1/3 the diagonal of the notification zone through which they are passing
![Page 15: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/15.jpg)
When is a Risk Analysis Required?
• When providing a mass notification system (MNS)
![Page 16: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/16.jpg)
![Page 17: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/17.jpg)
![Page 18: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/18.jpg)
2016 Proposed Changes
• 24.3.11.2 The detail and complexity of the risk analysis shall be commensurate with the complexity of the facility for which the mass notification system is designed.
• 24.3.11.3 The risk analysis shall be permitted to be limited in scope to address the communication requirements of an existing emergency response plan.
![Page 19: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/19.jpg)
When is a Risk Analysis Required?
• 24.4.3 In-Building Mass Notification Systems
![Page 20: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/20.jpg)
When is a Risk Analysis Required?
![Page 21: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/21.jpg)
When is a Risk Analysis Required?
• 24.4.4 Wide-Area Mass Notification
![Page 22: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/22.jpg)
When is a Risk Analysis Required?
• 24.6 Information, Command and Control
![Page 23: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/23.jpg)
![Page 24: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/24.jpg)
![Page 25: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/25.jpg)
![Page 26: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/26.jpg)
![Page 27: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/27.jpg)
Tools for the Risk Analysis
• A.24.3.11.1
![Page 28: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/28.jpg)
![Page 29: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/29.jpg)
Emergency Response Plan
• Emergency response team structure• Emergency response procedures
– Related to building system emergencies,– Personnel/occupant emergencies– Terrorism– Events of nature
• Emergency response equipment• Notification/communication
– Message content – Authority to communicate– Initiation procedure
• Emergency response training and drills
![Page 30: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/30.jpg)
Design Considerations
• Management/staff capabilities
• Extent of notification
• Coordination with the emergency response plan
![Page 31: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/31.jpg)
MNS Design Features driven by Risk Analysis
• Capability for remote operation• Definition of notification zones• Survivability of speaker circuits• Priority of signals and messages
(MNS versus fire)
![Page 32: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/32.jpg)
MNS Design Features driven by Risk Analysis
• Inclusion of devices to automatically activate MNS notification (i.e. CBRN)
• Type, location and security of control and interface equipment
• Control of other building systems (i.e., elevators, HVAC, security, process, etc.)
• Need for wide area MNS
![Page 33: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/33.jpg)
MNS Design Features driven by Risk Analysis
![Page 34: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/34.jpg)
Framework for Risk Analysis
I. Project description
II. Goals and purpose of MNS (user driven)
III. Expected characteristics of the occupants and management
IV. Occupancy/use characteristics
V. Anticipated events presenting a risk
VI. Design features required to address events presenting a risk
![Page 35: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/35.jpg)
Chapter 18 – Notification Appliances
• 18.4.1.4.1 – Designer required to identify rooms and spaces requiring audible notification
• 18.4.1.4.2 – Only requires audible devices in occupiable areas
• 18.4.1.4.3 – Requires the designer to document the sound pressure levels required to be produced
• 18.5.2 – Requires documentation of visual appliances
![Page 36: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/36.jpg)
Chapter 18 – Notification Appliances
• Designing for Intelligibility
![Page 37: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/37.jpg)
• Designing for Intelligibility
![Page 38: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/38.jpg)
Chapter 18 – Notification Appliances
• 18.4.10.2.1 – Specifically states that intelligibility is not required in every ADS (Acoustically Distinguishable Space)
• 2010 Edition of 72 incorporated the requirement that the designer identify ADSs
![Page 39: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/39.jpg)
ADS Example
![Page 40: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/40.jpg)
Chapter 18 – Notification Appliances
• Table 18.5.5.4.1 (a) – Revised to delete the column for installations using two lights per room on opposite walls
![Page 41: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/41.jpg)
Sponsored by:
Thank you!
Ray Grill, PE, FSFPE, LEED APPrincipal
Arup1120 Connecticut Avenue, N.W., Suite 200
Washington, DC [email protected]
![Page 42: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/42.jpg)
Ray Grill, PE, FSFPE, LEED AP, Arup, Washington, D.C.
Moderator: Jack Smith, Consulting-Specifying Engineer and CFE Media, LLC
Presenters:
![Page 43: Fire and Life Safety: Notification and Emergency Communication Systems](https://reader033.vdocuments.mx/reader033/viewer/2022061201/5479ac89b4af9fc9158b48be/html5/thumbnails/43.jpg)
Fire and Life Safety: Notification and Emergency
Communication Systems