fingerprinting technologies

4
LIVE SCAN TouchPrint High Definition 3800 Boost your crime solving capabilities with… The TouchPrint High Definition 3800 Full Hand Scanner from Identix ® Choose the system that provides • Better data • Maximum reliability • Reduces variability operator-to-operator With high quality full hand images you get the data you need to ID subjects - faster! ®

Upload: stefan-pinto

Post on 02-Mar-2016

239 views

Category:

Documents


1 download

DESCRIPTION

Identix' TouchPrint 3800ED Biometric Capture Device

TRANSCRIPT

Page 1: Fingerprinting Technologies

LIVE SCANTouchPrint™ High Defi nition 3800

Boost your crime solving capabilities with…

The TouchPrint™ High Defi nition 3800 Full Hand Scanner from Identix®

Choose the system that provides

• Better data

• Maximum reliability

• Reduces variability operator-to-operator

With high quality full hand images you get the data you need to ID subjects - faster!

®

Page 2: Fingerprinting Technologies

Capture of Critical Data Leads to Credible ArrestsPiecing together evidence to solve a crime is tough enough and to miss something critical can compromise an investigation. Investing in a full hand system means you are committed to capturing all the critical hand data for more positive identifi cations and more credible arrests. The TouchPrint High Defi nition 3800 Full Hand Scanner from Identix consistently delivers the highest quality full hand images and performs in a busy, chaotic environment – to settle for anything less could compromise your ability to solve future crimes.

Maximum Reliabilityfor High-Traffi c EnvironmentsThe TouchPrint High Defi nition 3800 Full Hand Scanner utilizes a single stationary camera and features a non-coated platen surface. Our design with a fi xed optics system and fewer moving parts – such as fans or a revolving camera – greatly simplifi es maintenance and helps ensure maximum uptime. Also, with no consumables, like silicon pads or coatings, image quality remains consistent and ongoing operating costs are kept low.

1. Cylindrical platen helps to ensure contact with all contoured regions of the hand

2. Optics system is fi xed – no moving parts; no fans, no revolving camera

3. Patented optics capture maximum friction ridge detail even when hands sweaty

1

2 3

Reduces Variabilityand Increases Processing Effi ciencyIntuitive operation and the patented curved platen allow operators to easily capture full-hand images – from the carpal crease to the fi ngertips – in a quick single step. Our hand scanner adapts an imaging concept long used in traditional inked palmprinting and recommended by the FBI – rolling the hand over a curved surface. Other scanners require specifi c hand positioning and excessive pressure to capture a full hand image, and may still miss the inner region of the palm or the interdigital area between the palm and fi ngers.

Palm captured with traditional palm or other hand scanners miss critical center region

Palm captured with TouchPrint High Defi nition 3800Full Hand Scanner captures all parts of the hand including cup of the palm

Powerful, New Advantages!The TouchPrint High Defi nition 3800 Full Hand Scanner is a critical piece of our Law Enforcement ID Solution. It give you powerful, new advantages that can make all the difference in making identifi cations, solving crimes and increasing processing effi ciency in your agency.

• Goes beyond FBI Appendix F Certifi cation to deliver superior image clarity and 1000 ppi resolution needed for positive identifi cation

• Features patented optics in the full hand scanner that ‘see’ through moisture, highlighting important friction ridge detail and helping to prevent false artifacts

• Optimizes workfl ow by extracting the slap image from the full hand scan - eliminates the need to capture four-fi nger slaps

• Centralizes administrative functions - operator training and certifi cation, user management, reporting, inventory control, hardware management - for greater operational effi ciency

Page 3: Fingerprinting Technologies

All Full Hand Scanners are Not Created Equal.

Better Data for Better Crime Solving

3

5

6

4

2

7

Processing Effi ciency

Actual image of the cup and thenar scanned using the TouchPrint™ Enhanced Defi nition 3800 Full Hand Scanner captured at 1000 ppi.

1

With the TouchPrint High Defi nition 3800Full Hand Scanner, the entire hand, from the fi ngertip to the carpal crease is captured in a single pass at 1000 ppi resolution, providing the superior image quality that only Identix can offer.

1 Fingerprints Fingerprints2 Interdigital Interdigital3 Cup Cup4 Thenar Thenar5 Hypothenar Hypothenar6 Carpal Crease Carpal Crease7 Writer’s PalmWriter’s Palm

Page 4: Fingerprinting Technologies

High Defi nition Takes Fingerprint Image Quality to a New Dimension• 1000 ppi resolution

• Greater ability to read features and ridge detail in fi ne ridge structures

• Increased accuracy of minutiae and ridge detail location

• Enhanced image sharpness and clarity

• Virtually no distortion

• No smudging and smearing

• No degradation in image quality over time

Advantages that mean even more when integrated in a broader solutionThe TouchPrint High Defi nition 3800 Law Enforcement ID Solution not only meets but exceeds your needs by providing:

• More data, better data

• Maximum reliability

• Greater operational effi ciency

All from the leader in the industry with a proven track record.

5600 Rowland RoadMinnetonka, MN 55343 USAPhone: +1 952-932-0888Fax: +1 952-932-7181

3975 Fair Ridge DriveFairfax, VA 22033 USAPhone: +1 703-259-5000Fax: +1 703-259-5001

®

www.identix.com • [email protected]

TOUCHPRINT™ HIGH DEFINITION 3800 LIVE SCAN WITH INTEGRATED FULL HAND SCANNER PRODUCT SPECIFICATIONS

TP-3800XC-HD TouchPrint High Defi nition 3800 Live Scan Booking Station (without integrated full hand scanner) has a built-in monitor and keyboard and fully featured application software on Windows XP for tenprint capture, storage and transmission

TP-3800XCH-HD TouchPrint High Defi nition 3800 Live Scan Booking Station with Integrated Full Hand Scanner has a built-in monitor and keyboard and fully featured application software on Windows XP for tenprint capture, storage and transmission

Image Quality Meets FBI IQS IAFIS Image Quality Specifi cation Appendix F

Optical Scanner Interface FireWire™ IEEE 1394, OHCI compliant

Optical Scanner Dimensions Deck W: 12.5in (32cm); H: 6.25in (16cm); D: 14in (35.5cm)

Package Weight 350lbs (158.8kg)Package Weight 350lbs (158.8kg)Package Weight

Voltage/Power Requirements 110-120/220-240 VAC, 50/60 Hz / 220W nominal, 350W maximum

Operating Environment Ambient temp: 40° – 104° F (5° – 40° C) Rel. Humidity: 20% – 80% non-condensing

Housing Dimensions W: 31.5in (80cm); H: 44.5in (113cm); D: 27in (68.5cm)

Data Content Demographics (customizable), fi ngerprints and photo image transmission in compliance with FBI’s Data Content Demographics (customizable), fi ngerprints and photo image transmission in compliance with FBI’s Data ContentEFTS in ANSI/NIST-CSL 1-1993 specifi ed format

Data Protocols SMTP / FTP / NFS / TCP/ IP sockets / VPN

Data Communication V.42 external modem, 56kbps synchronous communication, T-1 high-speed digital communications, Ethernet LAN communications, TCP/IP/NFS/FTP protocols; interfaces for Sagem Morpho; NEC®; Printrak, a Motorola Company® and Cogent Systems, Inc., Dermalog and AFIX Tracker AFIS protocols

Workstation Computer PentiumWorkstation Computer PentiumWorkstation Computer ® P4 1.7GHz with 256MB RAM (minimum)

Monitor 17" LCD fl at panel displayMonitor 17" LCD fl at panel displayMonitor

FINGERPRINT SCANNER

FBI Certifi cation TP- 5700 deck is FBI IQS Appendix F certifi ed and is incorporated into the TouchPrint High Defi nition 3800 Live Scan

Active Imaging Dimensions Roll Platen 1.6in x 1.5in (41mm x 38mm)

Rolled Print Size Image compliant with FBI standard at 1.6in X 1.5in (41mm x 38mm)

Slap Image Size The sequence slap of 4 fi ngers is captured off the hand scan of the whole subject’s hand

Optical Resolution True 1000 ppi image capture, with square pixels

Calibration Requirement Factory calibrated and sealed; automatic light-balance recalibration over time

Dynamic Range Greater than 8 bit, yielding over 256 gray scale depth

Dual Beam Illumination™ Delivers uniform illumination across entire platen, improving geo-accuracy

Clear Trace Imaging™ Reduces latent images between prints

Clean Image View™ Provides 70% or greater signal-to-noise ratio than Appendix F requirements, resulting in better ability to read features and detail in fi ne ridge structures

Precise Image Distribution™ Results in 200% less geometric distortion than what is required to meet Appendix F minimum requirements, resulting in enhanced accuracy of minutiae and ridge detail location

Fine Feature Contrast™ Provides 275% higher CTF/MTF performance than Appendix F requirements, resulting in enhanced image sharpness and clarity

AntiSmear™ Technology Prevents smudging and smearing during fi nger rolls

PerfectScan™ High resolution live video display of platen surface during roll and slap capture; real-time image quality assurance evaluates images and provides instant feedback

AccuCapture™ Slap-to-roll comparison software to helps to ensure correct sequencing

FINGERPRINT SCANNER OPTIONS

Demographic Data Import Open File Communication System (OFCS)

Image Compression FBI-accredited Wavelet Scalar Quantization (WSQ) processing and JPEG 2000

Photo Capture Optional NIST best practices photo capture S/W and H/W

Peripherals Wide array of peripheral devices available to further enhance performance

FULL HAND SCANNER

FBI Certifi cation TouchPrint-2700HD/2670HD Livescan Palm/Hand Scanner Device is FBI IQS Appendix F certifi ed at 1000 ppi and is incorporated into the TouchPrint High Defi nition 3800 Live Scan Full Hand Scanner

Active Imaging Dimensions Platen 8.5in x 5.12n (215mm x 130mm)

Optical Resolution 1000 dpi image capture, with square pixels

Calibration Requirement Automatic calibration

AccuCapture Plus Slap-to-roll and slap-to-hand comparison software to help ensure correct sequencing

Moisture Discriminating Optics™ Patented optics ignore moisture on the fi ngerprint, hand or on the platen

PerfectScan High resolution live video display of platen surface during roll and slap capture; real-time image quality assurance evaluates images and provides instant feedback

WARRANTY AND MAINTENANCE SUPPORT

Warranty One year limited warranty

Maintenance and Support Range of support packages available to partners and end-users

All the Benefi ts of the TouchPrintAll the Benefi ts of the TouchPrint™ High Defi nition Systems…

The Full Hand Scanner comes as a built-in component to the TouchPrint High Defi nition 3800 Booking Station offering a higher dimension in fi ngerprint image quality. With 1000 ppi resolution and new anti-smearing and anti-smudging technologies in the fi ngerprint optics deck, the TouchPrint High Defi nition 3800 Live Scan Booking Station provides the image quality that is so critical to better AFIS performance.

Identix, the Identix logo, Empowering Identifi cation, AccuCapture, AntiSmear, Clear Trace Imaging, Clean Image View, Dual Beam Illumination, Fine Feature Contrast, Moisture Discriminating Optics, PerfectScan, Precise Image Distribution and TouchPrint are registered trademarks or trademarks of Identix Incorporated. All other company and product names may be registered trademarks or trademarks of their respective owners. Copyright 2005

Identix Incorporated. All rights reserved. Printed in the USA. REV 02/05