filtomat m300 series - can-am · pdf filefiltomat ® m300 series amiad ... the m300 series...
TRANSCRIPT
FILTOMAT ® M300 SERIES
amiad filtration systems ENG
self-cleaning system
on the market
The most effective
Reliable supply of clean liquid
Wide choice of screen/meshsizes for variable dirt loads
Fully automated remoteoperation
Hydraulic operation; noexternal power source required
Permanent screen media
~
~~
~~
~
Compact lightweight design tomeet site infrastructure
Easy installation andmaintenance
Specially tailored filtersavailable
How do the M300 filters work ?
The M300 series removes dirtparticles as water flows throughthe coarse (1) and fine screens(2) to the outlet. The particlesaccumulate on the fine screeneventually increasing thepressure differential between itsinner and outer surfaces. At apreset value, the rinse controller(8) activates the hydraulic valves(5) and piston (6). This results inthe release a backflush streamthat flows out of the hydraulicmotor chamber (4) via thenozzles (3) to the drainage pipe.
This stream causes a pressuredrop in the motor chamber thatcreates the suction effect of thenozzles (5) for spot cleaning thefine screen’s inner surfacedirectly in front of the openingsof each nozzle. The helicalmovement of the dirt collectorassembly (9) ensures that thesuction nozzles sweep theentire inner surface of the finescreen as follows:
• The backflush water flowsthrough the dirt collectorpipe, via the hydraulic motor
(7) to the hydraulic valves (5).This causes the dirt collectorassembly (9) to spin. The firststroke begins when thepressure-drop in the motorchamber (4) and drainagefrom the piston drive thespinning dirt collectorassembly toward the piston.
• When the first stroke iscompleted, the dirt collector(9) moves toward the filtercover returning to its originalposition.
Outlet
Inlet
Drain
3
1
4
7
8
9
5
6
2
How the M400 bypass feature worksThe cost-effective built-in bypassfeature of the M400 filter ensuresthe constant supply of water to theend-user’s equipment or process.The bypass operation mode istriggered when the screen becomesblocked. In this mode, the M400releases unfiltered water essentialfor applications that require water -even if contaminated. Once thescreen is cleaned, the filteresumes normal operation.
The M400 bypass feature
Technical specifications FILTOMAT ® M300
I N - L I N E O N - L I N E B Y- PA S S
I N - L I N E O N - L I N E B Y- PA S S
M302LE
M303L
M303LE
M304L
M304LE
M306
M306E
M306L
M308
M310
M310L
M312
M314
160
160
205
100
100
125
450
450
900
4600
4600
9000
1532
1532
3065
40
40
80
M403LP
M404LPE
M404LP
140
155
153
80
95
93
450
450
450
4600
4600
4600
1532
1532
1532
25
40
40
M302LPE
M303LP
M303LPE
140
150
150
80
90
90
4600
4600
4600
1532
1532
1532
25
40
40
190
205
205
110
125
125
450
450
450
4600
4600
4600
1532
1532
1532
80
150
150
M404LPE
M406P
M406PE
180
152
188
100
92
108
900
450
450
9000
4600
4600
3065
1532
1532
80
80
150
M304LP
M304LPE
M306P
184
153
189
104
93
109
9000
4600
4600
3065
1532
1532
80
80
150
275
265
310
150
155
170
900
900
900
9000
13500
9000
3065
4598
3065
150
120
300
M406LP
M406XLP
M408P
198
250
252
108
127
142
450
900
900
4600
9000
13500
1532
3065
4698
150
150
120
M306PE
M306LP
M306XLP
200
253
292
110
130
152
4600
9000
9000
1532
3065
3065
150
150
300
370
630
660
190
390
405
900
1100
1100
13500
12300
18300
4598
4084
6127
300
400
400
M408LP
M410P
M410LP
284
340
500
144
160
260
900
900
1100
9000
13500
12300
3065
4598
4084
300
300
400
M308P
M308LP
M310P
494
560
640
254
280
300
12300
18300
18300
4084
6127
6127
400
400
600
780
900
1040
440
470
590
1100
1270
1270
18300
20500
20500
6127
6888
6888
600
900
1100
M412P
M414P
M416P
548
631
745
885
268
291
315
435
1100
1100
1270
1270
18300
18300
20500
20500
6127
6127
6888
6888
400
600
900
1100
M310LP
M312P
M314P
M316P
865435205006888900
FullEmpty
Weight, (kg)
Flat Zig-Zag
Screen Area(cm2)Flow
(m3/h)ModelFullEmpty
Weight, (kg)I.L.*(mm) Flat Zig-Zag
Screen Area(cm2)Flow
(m3/h)ModelFullEmpty
Weight, (kg)I.L.*(mm) Flat Zig-Zag
Screen Area(cm2)Flow
(m3/h)ModelI.L.*(mm)
564
604
604
748
748
910
910
910
1176
1340
1340
1450
1532
4-layer
2259
2259
2259
4878
2259
2259
2259
4878
4878
6723
1085
1085
11794
2259
2259
2259
4878
2259
2259
2259
4878
7477
4878
7477
6723
1085
1085
11794
11794
4-layer 4-layer
2259
2259
4878
2259
2259
2259
4878
7477
4878
7477
6723
1085
1085
11794
11794
10.90.80.70.6
0.50.4
0.3
0.2
0.1
P (BAR)
0.05
0.04
0.03
0.02
0.0110 3020 50 70 9040 60 80 100 200 400 600300 500 1000
M30
2
M30
3
M30
4
M31
0
M31
6
2000m3/h
M30
6
M30
8
M31
2
M31
4
4-layer4-layerFullEmpty
Weight, (kg)
Flat Zig-Zag
Screen Area(cm2)Flow
(m3/h)Model
95
115
70
80
205
300
1230
2310
406
766
25
40
M403P
M404P
60
71
95
40
46
60
150
205
300
1230
1230
2310
406
406
766
25
40
80
60
71
95
1230
1230
2310
406
406
766
25
40
80
M302L**
M303
M304
FullEmpty
Weight, (kg)I.L.*(mm) Flat Zig-Zag
Screen Area(cm2)Flow
(m3/h) FullEmpty
Weight, (kg)I.L.**(mm) Flat Zig-Zag
Screen Area(cm2)Flow
(m3/h)ModelI.L.*(mm)
580
604
748
4-layer
528
528
950
M302LP**
M303P
M304P
Model
528
528
950
528
950
40
46
60
Pressure losses for various flow capacitiesSpecifications for all models:
Working pressure: 10 bar gauge max.(16 bar gauge max. option).
Pressure during rinse cycle: 2 bar gauge min.;3.5 bar gauge min. for E models
Working temperature: 65 C max.
Rinse cycle duration: Pistonless model 3 to 5 sec.Piston model 10 to 15 sec.
* I.L. - Installation length.
** M302L and M302LP are 2" BSP or 2" NPT threaded inlet/outlet.
Note: The pressure losses for the M400 series is identical to the dataprovided in the graph above.
Singapore: F.C.S. Pte. Ltd. • 111 North Bridge Road • #07-07 Peninsula Plaza • Singapore 179098 • Tel: +65-6-337-6698 • Fax: +65-6-337-8180
France: Amiad France S.A.R.L. • 31 Boulevard Lefebvre • 75015 Paris • France • Tel: +33(0)1 56.08.55.22 • Fax: +33(0)1 45.30.25.96
North America: Amiad Filtration Systems • 2220 Celsius, Unit B • Oxnard, CA. 93030 • USA • Tel: (805)988-3323 • Fax: (805)988-3313
amiad
Typical applications
www.amiad.com
Ref: 95-044-650-001/11.04
filtration systems
Germany: Amiad Filtration Solutions • Gerstäckerstr. 9 • D-20459 Hamburg • Germany • Tel:+49-40-3609-6770 • Fax:+49-40-3609-6765
South America: Amiad Sur • Agustín de Urtubey 1379 • 11300 Montevideo • Uruguay • Tel: +598-2-628-0927 • Fax: +598-2-622-6991
D.N. Gali l Elyon 1 • 12335 • Israel • Tel: +972-4-690-9500 • Fax: +972-4-690-9391 • E-Mail: [email protected] and Head Office: Amiad Filtration Systems (1997) Ltd.
EN ISO 9001041000435
AMIAD products undergo constantmonitoring for quality control.The manufacturer reserves the right toincorporate changes and improvementsin the product without prior notice.
The
Stan
dards Institution of Israel
Qu
al i t y A s s u r e d
Fi r
m
M406LP by-pass filter - Japan.
M304LP for thick juice sugar mill - Sweden.M314P St/St in-take water at paper mill - Finland.
M303L in-line side stream filtration for cooling tower atpetro chemical plant - Israel.