7 7 Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield and external jacket in polyethylene type moisture barrier. Construction Conductor Soft copper wires Insulation Foam skin or solid high density polyethylene. Twisted Pairs Insulated conductors are twisted into pairs Core Assembly Up to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs) Spare pairs One spare pair white-red colored at the interstices of each 100 pairs unit, to guarantee nominal numbers of pairs. Identification Pairs, groups and units that conform the core, are identified by color code (Attached) Core Wrap Non-hygroscopic dielectric tape. Offers dielectric strength between core and sheath Shield Corrugated Aluminum tape both sides covered with copolymer Jacket Black polyethylene, abrasion, weather, and penetration to water resistant Outside Telephone Cable Filled Core. Moisture Barrier.

Upload: others

Post on 27-Dec-2019

9 views

Category:

Documents


0 download

TRANSCRIPT

77

Description

Soft copper wires insulated with high density polyethylene, foam skin or solid.Filled core, conformed by groups of pairs or by unit of groups of pairs. Aluminumshield and external jacket in polyethylene type moisture barrier.

Construction

ConductorSoft copper wires

InsulationFoam skin or solid high density polyethylene.

Twisted PairsInsulated conductors are twisted into pairs

Core AssemblyUp to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs,from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groupsof 25 pairs)

Spare pairsOne spare pair white-red colored at the interstices of each 100 pairs unit, toguarantee nominal numbers of pairs.

IdentificationPairs, groups and units that conform the core, are identified by color code(Attached)

Core WrapNon-hygroscopic dielectric tape. Offers dielectric strength between core andsheath

ShieldCorrugated Aluminum tape both sides covered with copolymer

JacketBlack polyethylene, abrasion, weather, and penetration to water resistant

Outside Telephone CableFilled Core. Moisture Barrier.

8

Moisture BarrierFilled Core with elastomeric compound, aluminum tape both sidescovered with copolymer and polyethylene external jacket, firmly bondedto external side of aluminum tape

OptionsManufacturing according to REA and/or Bellcore specificationsShield in Flat Aluminum tape. Armor in corrugated and copolymercovered Steel tape for direct buried and for rodent protection. Galvanizedsteel wires armor for vertical installations. Other Core Assemblies areavailable upon request.

ApplicationsTrunk cable and distribution cable networks. Special for wet locations;the elastomeric compound filler prevents the entrance of moisture tothe core. Installation in ducts or raceways; for buried direct in locationswithout heavy traffic.

CENTELSA Outside Telephone Cable, are able for voice and datatransmission up to 6.3 MHz, optimizing the bandwidth of copper cables.

Standards and Specifications

CENTELSA Outside Telephone Cable, are manufactured under thefollowing standards:

ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefininsulated copper conductor.

ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefininsulated copper conductor.

NTC-2061 Telecommunications copper conductor multipair cables,polyolefin insulated and covered, filled and dry.

Certifications

CENTELSA Outside Telephone Cable, are certified by:ICONTEC (Colombia). Norma NTC 2061.

Note: Other configurations, sizes, colors and length not specifiedherein are available upon request.

9Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL

WEIGTH(kg/km)

OVERALLDIAMETER

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

94141187231275356479692886

127016682044241935654699583769419126

120188252316378498682996

12831876244630373606531270188684

1038613682

158257350442531724994

1452188027323605447553097848

10374128461537120280

0.180.180.180.180.180.180.180.180.180.180.180.180.180.180.180.180.180.180.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.260.260.260.260.260.260.260.260.260.260.260.260.260.260.260.260.260.26

0.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.60

1.401.401.401.401.401.401.401.601.601.601.801.801.802.002.202.402.402.401.401.401.401.401.401.401.401.601.601.801.802.002.002.202.402.402.602.601.401.401.401.401.401.601.601.801.801.802.002.202.202.402.602.602.802.80

9.7511.5612.9614.1315.1716.9619.3022.8725.4829.9134.0637.3540.3248.4855.3261.4366.7375.8810.6712.8614.5515.9717.2319.4022.2226.4629.6235.4039.9244.3947.9957.6466.0372.9279.5790.6312.0814.8617.0018.8020.3823.5527.1332.3836.3943.2549.3854.8059.3571.6781.9990.7299.02

113.03

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

------12234569

12151824

------12234569

12151824

------12234569

12151824

Outside Telephone Cable.Filled Core. Moisture Barrier.Foamed-Skin polyethylene insulation.

Standards: ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefininsulated copper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.

10

Outside Telephone Cable.Filled Core. Moisture Barrier.Solid polyethylene insulation.

Standards: ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefininsulated copper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

106160211262311405548792

101514761913237728124128544067148026

10547142224306384459620850

12321590230030333762445465618663

107131281316877

177294407514624849

11681710221532624292532463209325

12270152601818324082

0.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.230.300.300.300.300.300.300.300.300.300.300.300.300.300.300.300.300.300.300.350.350.350.350.350.350.350.350.350.350.350.350.350.350.350.350.350.35

0.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.60

1.401.401.401.401.401.401.401.601.601.801.802.002.002.202.402.402.602.601.401.401.401.401.401.601.601.801.801.802.002.202.202.402.602.602.802.801.401.401.401.401.401.601.601.801.802.002.202.402.402.602.602.802.803.00

10.3412.4013.9815.3216.4918.5321.1825.1828.1533.5937.8342.0545.4354.5162.2668.8875.1385.5211.8314.5116.5718.3019.8322.9026.3431.4235.2741.8847.8153.0457.4269.3179.2687.6795.68

109.1813.1316.3518.8220.9022.7426.3330.4736.4941.1149.4556.4462.8368.1082.1193.57

104.08113.20129.82

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

------12234569

12151824

------12234569

12151824

------12234569

12151824

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL

WEIGTH(kg/km)

OVERALLDIAMETER

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

11

Outside Telephone Cable

Description

Soft copper wires insulated with high density polyethylene, foam skin or solid.Core conformed by groups of pairs or by unit of groups of pairs. Filled coreAluminum shield and double Jacket (inner and outer) in polyethylene typemoisture barrier.

Construction

ConductorSoft copper wires

InsulationFoam skin or solid high density polyethylene.

Twisted PairsInsulated conductors are twisted into pairs

Core AssemblyUp to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs,from 400 pairs and more, units of 100 pairs (each unit is conformed by 4 groupsof 25 pairs)

Spare pairsOne spare pair white-red colored at the interstices of each 100 pairs unit, toguarantee nominal numbers of pairs.

IdentificationPairs, groups and units that conform the core, are identified by color code(Attached)

Inner JacketBlack polyethylene, abrasion, weather, and penetration to water resistant

Filled Core. Double Jacket. Moisture Barrier.

12

Core WrapNon-hygroscopic dielectric tape. Offers dielectric strength betweencore and sheath

ShieldCorrugated Aluminum tape both sides covered with copolymer

Outer JacketBlack polyethylene, abrasion, weather, and penetration to waterresistant

Moisture BarrierFilled Core with elastomeric compound, inner polyethylene jacket,aluminum tape both sides covered with copolymer and outerpolyethylene external jacket, firmly bonded to external side of aluminumtape.

Options

Manufacturing according to REA and/or Bellcore specificationsShield in Flat Aluminum tape. Armor in corrugated and copolymercovered Steel tape for direct buried and for rodent protection. Galvanizedsteel wires armor for vertical installations. Other Core Assemblies areavailable upon request.

Applications

Trunk cable and distribution cable networks. Special for wet locations;the elastomeric compound filler prevents the entrance of moisture tothe core.

Trunk cable and distribution cable networks. Special for wet locations;the elastomeric compound filler prevents the entrance of moisture tothe core.

The inner jacket offers additional blocking to the entrance of humidityto the core, increases the dielectric strength pair-shield and improvescable resistance to penetration of sharp objects.

CENTELSA Outside Telephone Cable, are able for voice and datatransmission up to 6.3 MHz, optimizing the bandwidth of copper cables.

13

Standards and Specifications

CENTELSA Outside Telephone Cable, are manufactured under the followingstandards:

Standards:ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefin insulatedcopper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.

Certifications

CENTELSA Outside Telephone Cable, are certified by:ICONTEC (Colombia). Standard NTC 2061.

Note: Other configurations, sizes, colors and length not specified herein areavailable upon request.

14

Outside Telephone Cable.Filled Core. Moisture Barrier.Foamed-Skin polyethylene insulation.

Standards: ANSI/ICEA S-84-608 Telecommunications cable filled, polyolefininsulated copper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

116166215261307392519746947

134117592144252637124882605771739390

143216283350415539729

105913541971255231783751550272548938

1068614031

183285386481574780

10591539197728503754465655048104

10690131961577520748

0.180.180.180.180.180.180.180.180.180.180.180.180.180.180.180.180.180.180.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.260.260.260.260.260.260.260.260.260.260.260.260.260.260.260.260.260.26

0.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.60

1.401.401.401.401.401.401.401.601.601.601.801.801.802.002.202.402.402.401.401.401.401.401.401.401.401.601.601.801.802.002.002.202.402.402.602.601.401.401.401.401.401.601.601.801.801.802.002.202.202.402.602.602.802.80

11.1512.9614.3615.5316.5718.3620.7024.4727.0831.5135.8639.1542.1250.4857.5263.8369.1378.2812.0714.2615.9517.3718.6320.8023.6228.0631.2237.2041.7246.3949.9959.8468.4375.3282.1793.2313.4816.2618.4020.2021.7825.1528.7334.1838.1945.0551.3857.0061.5574.0784.5993.32

101.82115.83

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

------12234569

12151824

------12234569

12151824

------12234569

12151824

0.700.700.700.700.700.700.700.800.800.800.900.900.901.001.101.201.201.200.700.700.700.700.700.700.700.800.800.900.901.001.001.101.201.201.301.300.700.700.700.700.700.800.800.900.900.901.001.101.101.201.301.301.401.40

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL

WEIGTH(kg/km)

OVERALLDIAMETER

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

TOTALWEIGTH(kg/km)

15

Outside Telephone Cable

Description

Soft copper wires insulated with high density polyethylene, foam skin or solid. Aircore, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield andexternal jacket in polyethylene type moisture barrier.

Construction

ConductorSoft copper wires

InsulationFoam skin or solid high density polyethylene.

Twisted PairsInsulated conductors are twisted into pairs

Core AssemblyUp to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs)

Spare pairsOne spare pair white-red colored at the interstices of each 100 pairs unit, to guaranteenominal numbers of pairs.

IdentificationPairs, groups and units that conform the core, are identified by color code (Attached)

Core WrapNon-hygroscopic dielectric tape. Offers dielectric strength between core and sheath

ShieldCorrugated Aluminum tape both sides covered with copolymer

JacketBlack polyethylene, abrasion, weather, and penetration to water resistant

Air Core. Moisture Barrier.

16

Moisture BarrierFilled Core with elastomeric compound, aluminum tape both sides coveredwith copolymer and polyethylene external jacket, firmly bonded to externalside of aluminum tape

Options

Manufacturing according to REA and/or Bellcore specificationsShield in Flat Aluminum tape. Armor in corrugated and copolymer coveredSteel tape for direct buried and for rodent protection. Galvanized steel wiresarmor for vertical installations. Other Core Assemblies are available uponrequest.

Applications

Trunk cable and distribution cable networks. For use in pressurized networks.Installation in ducts or raceways

CENTELSA Outside Telephone Cable, are able for voice and data transmissionup to 6.3 MHz, optimizing the bandwidth of copper cables.

Standards and SpecificationsCENTELSA Outside Telephone Cable, are manufactured under the followingstandards:

ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulatedcopper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.

Certifications

CENTELSA Outside Telephone Cable, are certified by:ICONTEC (Colombia). Standard NTC 2061.

Note: Other configurations, sizes, colors and length not specified hereinare available upon request.

17

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

86125163200232300404579734

104713531678197729083800471655957438

108164217270318419566823

105415411998247829414323566270408372

11070133214288361433587801

11471478216528293515416461398113

100871200415884

0.150.150.150.150.150.150.150.150.150.150.150.150.150.150.150.150.150.150.170.170.170.170.170.170.170.170.170.170.170.170.170.170.170.170.170.170.210.210.210.210.210.210.210.210.210.210.210.210.210.210.210.210.210.21

0.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.60

1.401.401.401.401.401.401.401.601.601.601.601.801.802.002.002.202.202.601.401.401.401.401.401.401.401.601.601.801.802.002.002.202.202.402.402.601.401.401.401.401.401.601.601.601.601.801.802.002.002.202.402.602.602.80

9.4111.0912.3813.4614.4216.0818.2421.5723.9828.0831.5334.9837.7345.3151.2856.9261.6871.1010.2612.2813.8415.1516.3018.3120.9124.8627.7733.1337.3041.3944.7853.7160.9367.8573.6084.2211.4714.0015.9417.5819.0221.9425.1929.5933.2339.8245.0950.0954.2365.4474.8683.2190.39

103.54

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

------12234569

12151824

------12234569

12151824

------12234569

12151824

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL

WEIGTH(kg/km)

OVERALLDIAMETER

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

Outside Telephone Cable.Air Core. Moisture Barrier.Foamed-Skin polyethylene insulation.

Standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled anddry.

18

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Outside Telephone Cable.Air Core. Moisture Barrier.Solid polyethylene insulation.

Standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled anddry.

107160208254298385515738938

133417522138252036944858602471429417

137213284352418548742

107513782009260532283818560273839106

1088214297

172276374468560758

10341501193327873670454553807914

10442128951541420283

0.150.150.150.150.150.150.150.150.150.150.150.150.150.150.150.150.150.150.190.190.190.190.190.190.190.190.190.190.190.190.190.190.190.190.190.190.220.220.220.220.220.220.220.220.220.220.220.220.220.220.220.220.220.22

0.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.400.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.500.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.600.60

1.401.401.401.401.401.401.401.601.601.601.801.801.802.002.202.402.402.601.401.401.401.401.401.401.401.601.601.801.802.002.002.202.402.402.602.601.401.401.401.401.401.601.601.801.801.802.002.202.202.402.602.602.802.80

11.1513.5515.3916.9418.3020.6723.7528.3431.7937.6343.0547.3951.3262.0170.9278.8585.6598.1312.6615.6817.9919.9521.6724.6628.5434.2138.5646.4252.6358.5163.6176.7487.9197.39

106.37121.58

14.2117.8720.6823.0525.1429.1833.8940.6846.0254.9663.0670.0776.0791.95

105.41116.91127.71146.16

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

150015001500150015001500100010001000

750500500500350300250250250

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

102030405070

100150200300400500600900

1200150018002400

------12234569

12151824

------12234569

12151824

------12234569

12151824

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL

WEIGTH(kg/km)

OVERALLDIAMETER

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

19

Description

Soft copper wires insulated with high density polyethylene, foam skin or solid. Aircore, conformed by groups of pairs or by unit of groups of pairs. Aluminum shield,support messenger and external jacket in polyethylene type moisture barrier.

Construction

ConductorSoft copper wires

InsulationFoam skin or solid high density polyethylene.

Twisted PairsInsulated conductors are twisted into pairs

Core AssemblyUp to 70 pairs, groups of 10 pairs, from 100 to 300 pairs groups of 25 pairs, from 400pairs and more, units of 100 pairs (each unit is conformed by 4 groups of 25 pairs)

Spare pairsOne spare pair white-red colored at the interstices of each 100 pairs unit, to guaranteenominal numbers of pairs.

IdentificationPairs, groups and units that conform the core, are identified by color code (Attached)

Core WrapNon-hygroscopic dielectric tape. Offers dielectric strength between core and sheath

ShieldCorrugated Aluminum tape both sides covered with copolymer

Support Messenger7 Strand high strength galvanized steel wire.

JacketBlack polyethylene, abrasion, weather, and penetration to water resistant

Outside Telephone CableSelf-supportedFigure 8. Air Core. Moisture Barrier.

20

Moisture BarrierAir Core (for pressurerd systems) with elastomeric compound, aluminumflat tape both sides covered with copolymer and polyethylene external jacket,firmly bonded to external side of aluminum tape

Options

Manufacturing according to REA and/or Bellcore specificationsShield in corrugated Aluminum tape. Filled Core. Galvanized steel wiresfully flooded for corrosion protection. Other Core Assemblies are availableupon request.

Applications

For pressured systems overhead trunk cable and distribution cable networks.Aerial installation suspended from Messenger

CENTELSA Outside Telephone Cable, are able for voice and data transmissionup to 6.3 MHz, optimizing the bandwidth of copper cables.

Standards and Specifications

CENTELSA Outside Telephone Cable Figure 8, are manufactured under thefollowing standards:

ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulatedcopper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefininsulated and covered, filled and dry.

Certifications

CENTELSA Outside Telephone Cable, are certified by:ICONTEC (Colombia). Standard NTC 2061.

Note: Other configurations, sizes, colors and length not specified hereinare available upon request.

21

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Outside Telephone Cable.Figure 8. Air Core. Self Supported. Moisture Barrier.Foamed-Skin polyethylene insulation.

Standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled anddry.

221261298334368435536789946

1256242298352403453552780

103312661728

0.150.150.150.150.150.150.150.150.150.150.170.170.170.170.170.170.170.170.170.17

0.400.400.400.400.400.400.400.400.400.400.500.500.500.500.500.500.500.500.500.50

1.401.401.401.401.401.401.401.601.601.601.401.401.401.401.401.401.401.601.601.60

8.03 x 18.67 9.71 x 20.3511.00 x 21.6412.08 x 22.7213.04 x 23.6814.70 x 25.3416.86 x 27.5020.19 x 32.1522.61 x 34.5726.70 x 38.66 8.88 x 19.5210.90 x 21.5412.46 x 23.1013.77 x 24.4114.93 x 25.5716.93 x 27.5719.54 x 31.5023.48 x 35.4426.39 x 38.3531.34 x 43.30

150015001500150015001500100010001000

750150015001500150015001500100010001000

750

10 20 30 40 50 70100150200300 10 20 30 40 5070

100150200300

------1223------1223

1.571.571.571.571.571.571.572.032.032.031.571.571.571.571.571.572.032.032.032.03

77777777777777777777

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL

WEIGTH(kg/km)

EXTERNALDIMENSIONS

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

MESSENGER

STRANDSNo.

DIAMETER(mm)

22

Note: 1. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Outside Telephone Cable.Figure 8. Air Core. Self Supported. Moisture Barrier.Solid polyethylene insulation.

Standards: ANSI/ICEA S-85-625 Telecommunications cable aircore, polyolefin insulated copper conductor.NTC-2061 Telecommunications copper conductor multipair cables, polyolefin insulated and covered, filled anddry.

222263300336371439543799959

1277246305361414467570805

107113151800

0.150.150.150.150.150.150.150.150.150.150.190.190.190.190.190.190.190.190.190.19

0.400.400.400.400.400.400.400.400.400.400.500.500.500.500.500.500.500.500.500.50

1.401.401.401.401.401.401.401.601.601.601.401.401.401.401.401.401.401.601.601.60

8.03 x 18.67 9.71 x 20.3511.00 x 21.6412.08 x 22.7213.04 x 23.6814.70 x 25.3416.86 x 27.5020.19 x 32.1522.61 x 34.5726.70 x 38.66 9.10 x 19.7411.22 x 21.8612.85 x 23.4914.22 x 24.8615.43 x 26.0717.52 x 28.1620.25 x 32.2124.35 x 36.3127.40 x 39.3632.57 x 44.53

150015001500150015001500100010001000

750150015001500150015001500100010001000

750

102030405070

100150200300

102030405070

100150200300

------1223------1223

1.571.571.571.571.571.571.572.032.032.031.571.571.571.571.571.572.032.032.032.03

77777777777777777777

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL

WEIGTH(kg/km)

EXTERNALDIMENSIONS

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

MESSENGER

STRANDSNo.

DIAMETER(mm)

23

Description

Drop Wire Paralleled. Hard copper conductors or steel copper covered,polyethylene or PVC insulated.

Construction

ConductorHard copper or steel copper covered (CCS)

InsulationSingle layer Polyethylene for DWP-PE and insulation – jacket integral for DWP-2PE, weather resistant.Polyethylene Insulation and PVC jacket for DWP PE-PVC.Flame retardant PVC for DWP-PVC.Paralleled conductors with polarization ridge and conductor separator membrane.

Application

Self supporting one pair parallel conductor Drop Wire intended for aerial serviceconnection to the subscriber

Standards

CENTELSA telephone wires DWP are manufactured under the followingstandards:NTC 1300 Service Drop telephone wire, inside installations and jumper.

Certifications

CENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.

Package100 or 200 meters spools in corrugated carton boxes

Note: other configurations and sizes not specified in this catalogue are availableupon request.

Outside TelephoneWire DWPDrop Wire Paralell

24

Outside Telephone Wire (International System Unit)Drop Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

Outside Telephone Wire (International System Unit)Drop Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

0.800.80

0.80

0.800.801.50

MATERIALAISLAMIENTO

Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Hard cooper and 33.91 ohm-cmil/ft for steel copper covered.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Hard CopperHard Copper

CopperClad Steel

CopperClad Steel

Hard CopperHard CopperHard CopperHard CopperHard Copper

2 x 18

DWP PVC

APPROX.TOTAL

WEIGTH(kg/km)

INSULATIONMATERIAL

EXTERNALDIMENSIONS

(mm)

DCRESISTANCE

AT 20° C1

(ohm/km)

INSULATIONRESISTANCE

(Mohm-km)TYPE CONDUCTOR

CROSSSECTION

(mm2)

INSULATIONTHICKNESS

(mm)

ONECONDUCTOR

TENSILE STRENGTH(Nominal)

(MPa)

JACKETTHICKNESS

(mm)SIZE

No. x AWG

SEPARATOR(mm)

STRANDDIAMETER

(mm)

DWP PE CCS

DWP PVC CCS

2 x 182 x 20

2 x 18

2 x 182 x 20

DWP PE

2 x 182 x 182 x 20

DWP 2PE

DWP PE-PVC

2 x 18

2 x 182 x 20

2 x 18

2 x 182 x 202 x 182 x 182 x 20

1.02

1.020.81

1.02

1.020.811.021.020.81

0.82

0.820.52

0.82

0.820.520.820.820.52

PE

PVCPVC

PVC

PEPEPEPEPE

0.80

0.800.80

0.80

0.800.801.600.700.70

1.00

1.001.00

1.00

1.001.00

---

-

--

-

---

0.800.80

2.62 x 6.25

2.62 x6.252.41 x 5.83

2.62 x 6.25

2.62 x 6.252.41 x 5.834.22 x 7.174.02 x 8.053.81 x 7.63

23

2922

28

2418364940

72.6

22.235.2

72.6

22.235.222.222.235.2

6229

249288

249

622972027167

362409

875

460473

875

460473460460473

Notas: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Hard cooper and 58.62 ohm-mm2/km for steel copper covered.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Hard CopperHard Copper

CopperClad Steel

CopperClad Steel

Hard CopperHard CopperHard CopperHard CopperHard Copper

2 x 18

DWP PVC

APPROX.TOTAL

WEIGTH(pound/kft)

INSULATIONMATERIAL

EXTERNALDIMENSIONS

(mils)

DCRESISTANCE

AT 20° C1

(ohm/kft)

INSULATIONRESISTANCE

(Mohm/kft)TYPE CONDUCTOR

CROSSSECTION

(kcmil)

INSULATIONTHICKNESS

(mils)

ONECONDUCTOR

TENSILE STRENGTH(Nominal)

(ksi)

JACKETTHICKNESS

(mils)SIZE

No. x AWG

SEPARATOR(mils)

STRANDDIAMETER

(mils)

DWP PE CCS

DWP PVC CCS

2 x 182 x 20

2 x 18

2 x 182 x 20

DWP PE

2 x 182 x 182 x 20

DWP 2PE

DWP PE-PVC

2 x 18

2 x 182 x 20

2 x 18

2 x 182 x 202 x 182 x 182 x 20

40

4032

40

4032404032

1.63

1.631.02

1.63

1.631.021.631.631.02

PE

PVCPVC

PVC

PEPEPEPEPE

31

3131

31

3131632828

39

3939

39

3939---

-

--

-

---

3131

103 x 246

103 x 24695 x 229

103 x 246

103 x 24695 x 229

166 x 282158 x 317150 x 300

15

2015

19

1612253327

22.1

6.7710.7

22.1

6.7710.76.776.7710.7

6229

817944

817

204372362823514

11881342

875

6769

127

6769676769

25

Outside TelephoneWire DWTDrop Wire Twisted

Description

Drop Wire Twisted. Hard copper conductor, individually insulated with polyethyleneor PVC.

Construction

ConductorHard copper

InsulationBlack Polyethylene weather resistant or flame retardat PVC.

Application

Self supporting one pair twisted conductor Drop Wire intended for aerial serviceconnection to the subscriber

Standards

CENTELSA telephone wires DWT are manufactured under the following standards:NTC 1300 Service Drop telephone wire, inside installations and jumper.

Certifications

CENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.

Package100 or 200 meters spools in corrugated carton boxes

Note: other configurations and sizes not specified in this catalogue are availableupon request.

26

Outside Telephone Wire (International System Unit)Drop Wire Twisted

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

0.820.520.820.52

2 x 182 x 202 x 182 x 20

DWT PVCDWT PVCDWT PEDWT PE

1.020.811.020.81

249288

62297202

22.735.922.735.9

28212317

460473460473

0.800.800.800.80

2.622.412.622.41

5.254.835.254.83

APPROX.TOTAL

WEIGTH(kg/km)

CROSSSECTION

(mm2)

EXTERNALDIAMETER

(mm)

DCRESISTANT

AT 20°C1

(ohm/km)

INSULATIONRESISTANCE

(Mohm-km)

TYPE SIZENo. x AWG

STRANDDIAMETER

(mm)

ONE CONDUCTORTENSILE STRENGTH

(Nominal)(MPa)

INSULATIONTHICKNESS

(mm)

DIAMETEROVER

INSULATION(mm)

Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Hard cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Outside Telephone WireDrop Wire Twisted

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

1.631.021.631.02

2 x 182 x 202 x 182 x 20

DWT PVCDWT PVCDWT PEDWT PE

40324032

817944

2043723628

6.9011.06.9011.0

19141611

67696769

31313131

10395

10395

207190207190

APPROX.TOTAL

WEIGTH(pound/kft)

CROSSSECTION

(kcmil)

EXTERNALDIAMETER

(mils)

DCRESISTANT

AT 20°C1

(ohm/kft)

INSULATIONRESISTANCE

(Mohm-kft)

TYPE SIZENo. x AWG

STRANDDIAMETER

(mils)

ONE CONDUCTORTENSILE STRENGTH

(Nominal)(ksi)

INSULATIONTHICKNESS

(mils)

SEPARATOR(mils)

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Hard cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

27

Description

Soft copper wires insulated with flame retardant PVC, paired, unshielded or shieldedwith aluminum foil and drain wire, external PVC jacket.

Construction

ConductorSoft copper

InsulationFlame retardant PVC

PairsTwo insulated conductor twisted together

CoreUp to 25 pairs one group of pairs, for 30 pairs and more, groups of 10 or 25 pairs.

Spare pairsOne pair color coded White-Red for 10 pairs or more.

IdentificationPairs, groups an units in the assembly core, are identified by color code (includedin this catalogue)

Core WrapNon hygroscopic polyester tape

ShieldUnshielded or shielded with aluminum foil and tinned copper drain wire

JacketFlame retardant PVC, gray colored.

Characteristics

Mutual capacitance120 nF/km.Capacitive Unbalance400 pF (referred to 500 m).

Inside Telephone Cables

28

DC Conductor Resistance97.8 ohm/km.

Maximum Operating Voltage60 V.

Insulation Resistance500 Mohm-km.

Dielectric Strength (60 seg)1000 V AC, 1500 V DC.

Applications

For inside residential commercial and industrial applications. Appropriatefor locations with electric interference produced by near power electric circuit.

Installation in dry locations in ducts trays and race ways.

Standards

CENTELSA Inside Cables are manufactured under the following standards:

NTC-983, IEC 189. Cables e hilos para bajas frecuencias con aislamientoy cubierta en PVC.

Notes: 1. Optionally with tinned copper conductor2. Other configurations and sizes not specified in this catalogue are available upon request.

29

Note: Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Unshielded Telephone Cable

Standards: Low Frecuency Cables and Wire with PVC Insulation and PVC Sheat.

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL WEIGTH

(kg/km)

OVERALLDIAMETER

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

15222834404979

139168200255310424584

0.200.200.200.200.200.200.200.200.200.200.200.200.200.20

0.500.500.500.500.500.500.500.500.500.500.500.500.500.50

0.600.600.600.600.600.700.700.800.800.900.900.901.001.00

3.183.934.504.985.406.007.269.46

10.3211.3212.7213.9516.3119.03

1001000100010001000100020002000200020001500100010001000

123456

10202530405070

100

------11111111

Note: Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Unshielded Telephone Cable

Standards: Low Frecuency Cables and Wire with PVC Insulation and PVC Sheat.

16233036425181

142171204259314429590

0.200.200.200.200.200.200.200.200.200.200.200.200.200.20

0.500.500.500.500.500.500.500.500.500.500.500.500.500.50

0.600.600.600.600.600.700.700.800.800.900.900.901.001.00

3.364.114.685.165.586.187.449.64

10.5011.5012.9014.1316.4919.21

1001000100010001000100020002000200020001500100010001000

123456

10202530405070

100

------11111111

NOMINALPAIRS

STANDARDLENGTHBY REEL

(m)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL WEIGTH

(kg/km)

OVERALLDIAMETER

(mm)

SPAREPAIRS

CONDUCTORDIAMETER

(mm)

JACKETTHICKNESS

(mm)

30

Description

Twisted pair for cross connections, for inside use. Soft tinned copper insulatedwith PVC or PVC and Nylon, assembly in pairs, triads or quads.

Construction

ConductorSoft tinned copper wire

InsulationFlame retardant PVC for JWT.Flame retardant PVC insulation; abrasion oil and gasoline resistant Nylonjacket for JWT PVC-NY.

Applications

JWT: twisted telephone wire for inside use, cross connections, telephonicderivations and radio and TV equipment wiring.

JWT PVC-NY: connection wire in distributors, mini-distributors and telephonicequipment. Nylon jacket provides abrasion resistance.

JWT NY: connection wire in distributors, mini-distributors and telephonicequipment.

Radio and TV equipment wiring, weld able without remove the insulation,Diameter reduced tightness and low friction advantages given by Nyloninsulation. Installation in dry locations, ducts or open installation.

Standards

CENTELSA telephone wires JWT are manufactured under the followingstandards:NTC 1300 Service Drop telephone wire, inside installations and jumper.

Inside TelephoneWire JWTJumper Wire Twisted

31

CertificationsCENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.

Package100 or 200 meters spools in corrugated carton boxes

Note: other configurations and sizes not specified in this catalogue are availableupon request.

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWT PVC(International System Units)Jumper Wire Twisted PVC

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

0.320.320.320.210.210.210.280.280.280.200.200.20

2 x 223 x 224 x 222 x 243 x 244 x 242 x 0.63 x 0.64 x 0.62 x 0.53 x 0.54 x 0.5

0.640.640.640.510.510.510.600.600.600.500.500.50

174174174180180180183183183183183183

57.457.457.491.091.091.066.066.066.095.095.095.0

8.412.616.8

5.48.1

10.97.6

11.315.1

5.27.9

10.5

0.300.300.300.250.250.250.300.300.300.250.250.25

1.241.241.241.011.011.011.201.201.201.001.001.00

2.492.683.002.022.182.442.402.592.902.002.162.41

SIZEAWG or mm

DCRESISTANCE

AT 20° C¹(ohm/km)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL WEIGTH

(kg/km)

OVERALLDIAMETER

(mm)

STRANDDIAMETER

(mm)

CROSSSECTION

(mm²)

EXTERNALDIAMETER

(mm)

INSULATIONRESISTANCE

(Mohm/km)

32

Inside Telephone Wire JWT PVC-NYJumper Wire Twisted PVC-Nylon

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

0.250.400.64

2 x 262 x 242 x 22

15.920.125.3

126108

91

44.427.717.5

2.63.75.3

4.34.34.3

38.042.247.4

75.984.394.7

6.76.76.7

29.333.538.7

Inside Telephone Wire JWT PVC-NY(International System Units)Jumper Wire Twisted PVC-Nylon

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

APPROX.TOTAL

WEIGTH(kg/km)

CROSSSECTION

(mm2)

EXTERNALDIAMETER

(mm)

DCRESISTANCE

AT 20°C1

(ohm/km)

INSULATIONRESISTANCE

(Mohm-km)

SIZEAWG or mm

STRANDDIAMETER

(mm)

JACKETTHICKNESS

(mm)

DIAMETEROVER JACKET

(mm)

NSULATIONTHICKNESS

(mm)

DIAMETEROVER

INSULATION(mm)

0.130.210.320.130.200.28

2 x 262 x 242 x 222 x 0.42 x 0.52 x 0.6

0.400.510.640.400.500.60

393328393329

14691.057.414895.066.0

3.85.57.93.85.37.1

0.110.110.110.110.110.11

0.961.071.200.961.061.16

1.932.142.411.922.122.32

0.170.170.170.170.170.17

0.740.850.980.740.840.94

Inside Telephone Wire JWT PVCJumper Wire Twisted PVC

Standards: NTC 1300 Service Drop telephone wire, inside installations andjumper.

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

0.640.640.640.400.400.40

2 x 223 x 224 x 222 x 243 x 244 x 24

252525202020

572572572592592592

17.517.517.527.727.727.7

5.78.5

11.33.65.57.3

11.811.811.89.89.89.8

48.948.948.939.839.839.8

97.9105.5118.179.685.896.1

SIZEAWG or mm

DCRESISTANCE

AT 20° C¹(ohm/kft)

INSULATIONTHICKNESS

(mils)

APPROX.TOTAL WEIGTH

(pound/kft)

OVERALLDIAMETER

(mils)

STRANDDIAMETER

(mils)

CROSSSECTION(sq inches)

EXTERNALDIAMETER

(mils)

INSULATIONRESISTANCE

(Mohm/kft)

APPROX.TOTAL

WEIGTH(kg/km)

CROSSSECTION(sq inches)

EXTERNALDIAMETER

(mils)

DCRESISTANCE

AT 20°C1

(ohm/km)

INSULATIONRESISTANCE

(Mohm-km)

SIZEAWG or mm

STRANDDIAMETER

(mils)

JACKETTHICKNESS

(mils)

DIAMETEROVER JACKET

(mils)

NSULATIONTHICKNESS

(mils)

DIAMETEROVER

INSULATION(mils)

33

Notes: 1. DC resistance calculated based on a 17.93 ohm-mm2/km resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWT NY(International System Units)Jumper Wire Twisted PVC-Nylon

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

0.130.210.320.130.200.28

2 x 262 x 242 x 222 x 0.42 x 0.52 x 0.6

0.400.510.640.400.500.60

101010101010

14691.057.414895.066.0

3.04.56.83.04.36.0

0.170.170.170.170.170.17

0.740.850.980.740.840.94

1.491.832.371.481.812.27

Inside Telephone Wire JWT NYJumper Wire Twisted PVC-Nylon

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

Notes: 1. DC resistance calculated based on a 10.785 ohm-cmil/ft resistivity for Tinned cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

0.250.400.64

2 x 262 x 242 x 22

15.920.125.3

333333

44.427.717.5

2.03.04.6

6.76.76.7

29.333.538.7

58.672.293.4

SIZEAWG or mm

DCRESISTANCE

AT 20° C¹(ohm/km)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL WEIGTH

(kg/km)

DIAMETEROVER

INSULATION(mm)

STRANDDIAMETER

(mm)

CROSSSECTION

(mm²)

EXTERNALDIAMETER

(mm)

INSULATIONRESISTANCE

(Mohm/km)

SIZEAWG or mm

DCRESISTANCE

AT 20° C¹(ohm/kft)

INSULATIONTHICKNESS

(mils)

APPROX.TOTAL WEIGTH

(pound/kft)

DIAMETEROVER

INSULATION(mils)

STRANDDIAMETER

(mils)

CROSSSECTION(sq inches)

EXTERNALDIAMETER

(mils)

INSULATIONRESISTANCE

(Mohm/kft)

34

Description

Inside drop wire paralleled. Soft copper insulated with PVC.

Construction

ConductorSoft copper wire

InsulationFlame retardant white PVC, paralleled conductors with polarization ridge.

Applications

Paralleled telephone wire for inside use from the interior box to exterior box;telephonic derivations.

Installation in dry locations, ducts or open installation.

Standards

CENTELSA telephone wires JWP are manufactured under the followingstandards:NTC 1300 Service Drop telephone wire, inside installations and jumper.

Certifications

CENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.

Package100 or 200 meters spools in corrugated carton boxes

Note: other configurations and sizes not specified in this catalogue areavailable upon request.

Inside TelephoneWire JWPJumper Wire Parallel

35

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for Soft cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWP(International System Units)Jumper Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

0.520.32

2 x 202 x 22

0.810.64

240279

33.954.2

18.113.5

0.600.60

2.01 x 4.031.84 x 3.69

Notes: 1. DC resistance calculated based on a 10.371 ohm-cmil/ft resistivity for Soft cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

1.020.64

2 x 202 x 22

32.025.3

787914

10.316.5

12.29.1

23.623.6

79.3 x 158.572.6 x 145.1

Inside Telephone Wire JWPJumper Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZEAWG or mm

DCRESISTANCE

AT 20° C¹(ohm/km)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL WEIGTH

(kg/km)

STRANDDIAMETER

(mm)

CROSSSECTION

(mm²)

EXTERNALDIAMETER

(mm)

INSULATIONRESISTANCE

(Mohm/km)

SIZEAWG or mm

DCRESISTANCE

AT 20° C¹(ohm/kft)

INSULATIONTHICKNESS

(mils)

APPROX.TOTAL WEIGTH

(pound/kft)

STRANDDIAMETER

(mm)

CROSSSECTION

(kcmil)

EXTERNALDIAMETER

(mils)

INSULATIONRESISTANCE

(Mohm/kft)

34

Description

Inside drop wire paralleled. Soft copper insulated with PVC.

Construction

ConductorSoft copper wire

InsulationFlame retardant white PVC, paralleled conductors with polarization ridge.

Applications

Paralleled telephone wire for inside use from the interior box to exterior box;telephonic derivations.

Installation in dry locations, ducts or open installation.

Standards

CENTELSA telephone wires JWP are manufactured under the followingstandards:NTC 1300 Service Drop telephone wire, inside installations and jumper.

Certifications

CENTELSA Outside Telephone Wire, are certified by:CIDET (Colombia). Standard NTC 1300.

Package100 or 200 meters spools in corrugated carton boxes

Note: other configurations and sizes not specified in this catalogue areavailable upon request.

Inside TelephoneWire JWPJumper Wire Parallel

35

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for Soft cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Inside Telephone Wire JWP(International System Units)Jumper Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

0.520.32

2 x 202 x 22

0.810.64

240279

33.954.2

18.113.5

0.600.60

2.01 x 4.031.84 x 3.69

Notes: 1. DC resistance calculated based on a 10.371 ohm-cmil/ft resistivity for Soft cooper.2. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

1.020.64

2 x 202 x 22

32.025.3

787914

10.316.5

12.29.1

23.623.6

79.3 x 158.572.6 x 145.1

Inside Telephone Wire JWPJumper Wire Parallel

Standards: NTC 1300 Service Drop telephone wire, inside installations and jumper.

SIZEAWG or mm

DCRESISTANCE

AT 20° C¹(ohm/km)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL WEIGTH

(kg/km)

STRANDDIAMETER

(mm)

CROSSSECTION

(mm²)

EXTERNALDIAMETER

(mm)

INSULATIONRESISTANCE

(Mohm/km)

SIZEAWG or mm

DCRESISTANCE

AT 20° C¹(ohm/kft)

INSULATIONTHICKNESS

(mils)

APPROX.TOTAL WEIGTH

(pound/kft)

STRANDDIAMETER

(mm)

CROSSSECTION

(kcmil)

EXTERNALDIAMETER

(mils)

INSULATIONRESISTANCE

(Mohm/kft)

36

Electrical CharacteristicsOutside Telephone Cables

MUTUAL CAPACITANCE(nF/km)

SIZE (mm)

Nominal1Maximum averageMaximum individual

0.4525564

0.5525564

0.6525564

Conductor DC Resistance(ohm/km)

SIZE (mm)

Maximum averageMaximum individual

0.4144.0150.0

0.592.195.9

0.663.966.6

RESISTIVE UNBALANCE1

(%)SIZE (mm)

Maximum averageMaximum individual

0.42.05.0

0.51.55.0

0.61.54.0

1500 5000

INSULATION RESISTANCE(Mohm-km)

Filled Core Air Core

Conductor A vs Conductor B

Conductor vs Shield

2000V, 3s1000V, 60s

6000V, 3s3000V, 60s

1000V, 3s500V, 60s2000V, 3s

1000V, 60s

DIELECTRIC STRENGTH(Volts)

SOLIDPOLYETHYLENE

FOAM SKINPOLYETHYLENE

MAXIMUM AVERAGEATENUATION1

(db/km)

SIZE (mm)

A 1000 HzA 150 kHzA 772 kHz

0.41.8812.123.0

0.51.518.9018.4

0.61.266.9015.5

Notes: 1. Test or value not indicated in Standard NTC 2061.2. Data herein indicated are subject to normal tolerances.

Pair to pair (pF refered to 500m)Pair to shield1 (pF/km)

2502625

150-

CAPACITIVE UNBALANCE(pF refered to 500m)

INDIVIDUALVALUE

95%OF VALUES

CROSSTALK Power Sum dB/305m

ELFEXT

150772

160031506300

0.4 mm6147413529

0.5 mm6349423731

0.6 mm6349433731

0.4, 0.5 and 0.6 mm5743373125

Average AverageFrequencykHz

0.4, 0.5 and 0.6 mm5847433834

0.4, 0.5 and 0.6 mm5342383329

ELNEXTWorst Pair Worst Pair

37

Pairs Codes in 25 Pairs GroupsInside¹ and Outside Telephone Cables

123456789

10

WHITEWHITEWHITEWHITEWHITEREDREDREDREDRED

BLUEORANGEGREENBROWNGREYBLUE

NARANJAGREENBROWNGREY

PAIR No.INSULATION COLOR

CONDUCTOR A CONDUCTOR B

10 PAIRS GROUP COLOR CODE

123456789

10111213141516171819202122232425

WHITEWHITEWHITEWHITEWHITEREDREDREDREDRED

BLACKBLACKBLACKBLACKBLACK

YELLOWYELLOWYELLOWYELLOWYELLOWPURPLEPURPLEPURPLEPURPLEPURPLE

BLUEORANGEGREENBROWNGREYBLUE

ORANGEGREENBROWNGREYBLUE

ORANGEGREENBROWNGREYBLUE

ORANGEGREENBROWNGREYBLUE

ORANGEGREENBROWNGREY

PAIR No.INSULATION COLOR

CONDUCTOR A CONDUCTOR B

PAIRS CODES IN 25 PAIRS GROUPS

CONSTRUCTION GROUP No. PAIRS

GROUP IDENTIFICATION

BINDER COLOR

10 PAIRGROUPS

25 PAIRGROUPS

1234567123456789

101112

1 to 1011 to 2021 to 3031 to 4041 to 5051 to 6061 to 70

1 to 2526 to 5051 to 75

76 to 100101 to 125126 to 150151 to 175176 to 200201 to 225226 to 250251 to 275276 to 300

WHITE - BLUEWHITE - ORANGEWHITE - GREENWHITE - BROWNWHITE- GREYRED - BLUERED - ORANGEWHITE - BLUEWHITE - ORANGEWHITE - GREENWHITE - BROWNWHITE- GREYRED - BLUERED - ORANGERED - GREENRED - BROWNRED - GREYBLACK - BLUEBLACK - ORANGE

Note: 1. Specifications for inside telephone cables up to 100 pairs.

38

Unit Color Code IdentificationOutside Telephone Cables

25 PAIRS

1234

WHITE - BLUEWHITE - ORANGEWHITE - GREENWHITE - BROWN

CONSTRUCTION GROUP No. BINDER COLOR

IDENTIFICATION FOR 4 GROUPS IN 100 PAIRS UNITS

CONSTRUCTION UNIT No. BINDER COLOR

UNITS IDENTIFICATION

PAIRS

100 PAIRS UNIT(4 GROUPSOF 25 PAIRS

EACH)

123456789

101112131415161718192021222324

WHITE - BLUEWHITE - ORANGEWHITE - GREENWHITE - BROWNWHITE - GREYRED - BLUERED - ORANGERED - GREENRED - BROWNRED - GREYBLACK - BLUEBLACK - ORANGEBLACK - GREENBLACK - BROWNBLACK - GREYYELLOW - BLUEYELLOW - ORANGEYELLOW - GREENYELLOW - BROWNYELLOW - GREYPURPLE - BLUEPURPLE - ORANGEPURPLE - GREENPURPLE - BROWN

1 to 100101 to 200201 to 300301 to 400401 to 500501 to 600601 to 700701 to 800801 to 900

901 to 10001001 to 11001101 to 12001201 to 13001301 to 14001401 to 15001501 to 16001601 to 17001701 to 18001801 to 19001901 to 20002001 to 21002101 to 22002201 to 23002301 to 2400

39

PAIRS ASSEMBLY GROUPS BY UNIT

CORE ASSEMBLY IN GROUPS OR UNITS

PAIRS BY GROUP

102030405070

100150200300400500600900

12001500180021002400

(0+1)(0+2)(0+3)(0+4)(0+5)(1+6)(0+4)(1+5)(2+6)(3+9)(0+4)(0+5)(1+5)(2+7)(3+9)

(1+5+9)(2+6+10)(2+8+11)(2+8+14)

10101010101025252525252525252525252525

GROUPSGROUPSGROUPSGROUPSGROUPSGROUPSGROUPSGROUPSGROUPSGROUPS

UNITSUNITSUNITSUNITSUNITSUNITSUNITSUNITSUNITS

----------444444444

Unit Color Code IdentificationOutside Telephone Cables

40

Assembly and Identificationfor Multipair Telephone Cable CoreInside¹ and Outside Telephone Cables

20 Pairs Assembly (0+2)

20 to 70 pairs

10 PAIRS GROUP CABLES

WhiteOrange

WhiteBlue

50 Pairs Assembly (0+5)

WhiteGrey White

Blue

WhiteGreen

WhiteOrange

WhiteBrown

40 Pairs Assembly (0+4)

WhiteBrown

WhiteBlue

WhiteGreen

WhiteOrange

30 Pairs Assembly (0+3)

WhiteGreen

WhiteBlue

WhiteOrange

70 Pairs Assembly (1+6)

RedBlue

WhiteOrange

WhiteGrey

BlancoVerde

RedOrange

WhiteBrown

WhiteBlue

100 Pairs Assembly (0+4)

100 to 300 pairs

25 PAIRS GROUP CABLES

WhiteBrown

WhiteBlue

WhiteGreen

WhiteOrange

200 Pairs Assembly (2+6)

RedOrange

White Green

RedBlue

WhiteBrown

RedGreen

WhiteGrey

WhiteOrange

WhiteBlue

300 Pairs Assembly (3+9)

RedGrey White

Brown

RedGreen

WhiteGrey

BlackBlue

RedBlue

White Green

WhiteBlue

WhiteOrange

BlackOrange

RedOrange

RedBrown

150 Pairs Assembly (1+5)

WhiteOrangeWhite

Grey WhiteGreen

RedBlue

WhiteBrown

WhiteBlue

Note:: 1.Specifications for telephone cables up to 100 pairs.

41

1500 Pairs Assembly (1+5+9)400 Pairs Assembly (0+4)

400 to 2400 pairs

100 PAIRS UNIT CABLES(EACH UNIT 4 GROUPS OF 25 PAIRS)

WhiteBlue

WhiteOrange

WhiteGreen

WhiteBrown

2100 Pairs Assembly (2+8+11)

2400 Pairs Assembly (2+8+14)

1800 Pairs Assembly (2+6+10)

1200 Pairs Assembly (3+9)

RojoGris White

Brown

RedGreen

WhiteGrey

BlackBlue

RedBlue

WhiteGreen

WhiteBlue

WhiteOrange

BlackOrange

RedOrange

RedBrown

900 Pairs Assembly (2+7)

RedGreen White

Green

WhiteBrown

RedBlue White

Grey

WhiteOrange

WhiteBlue

RedBrown

RedOrange

600 Pairs Assembly (1+5)

WhiteGrey

WhiteOrange

WhiteGreen

RedBlue

WhiteBrown

WhiteBlue

500 Pairs Assembly (0+5)

WhiteGrey White

Blue

WhiteGreen

WhiteOrange

WhiteBrown

WhiteGrey

WhiteOrange

WhiteGreen

RedBlue

WhiteBrown

WhiteBlue

Black Grey

RedOrng

RedGreen

RedBrownRed

Grey

Black Blue

BlackOrng

BlackGreen

Black Brown

Yellow Green

Red Brown

RedGrey

Black Blue

BlackOrange

Black Green

BlackGrey

YellowBlue

YellowOrange

RedOrange

White Green

RedBlue

WhiteBrown

RedGreen

WhiteGrey

WhiteOrange

WhiteBlue

BlackBrown

Purple Blue

Black Blue

BlackOrange

BlackGreen

BlackBrown

Black Grey

YellowGreen

YellowBrown

YellowGrey

RedGreen

WhiteGreen

RedOrange

WhiteBrown

RedBrown

RedBlue

WhiteOrange

WhiteBlue

Yellow Blue White

Grey

RedGrey

YellowOrange

Purple Brown

Black Blue

BlackOrange

OrangeGreen

BlackGrey

Yellow Blue

YellowGrey

PurpleBlue

PurpleOrange

RedGreen

WhiteGreen

RedOrange

WhiteBrown

RedBrown

RedBlue

WhiteOrange

WhiteBlue

Yellow Green

WhiteGrey

RedGrey

YellowBrown

YellowOrange

BlackBrown

Purple Green

Assembly and Identificationfor Multipair Telephone Cable CoreInside¹ and Outside Telephone Cables