TRANSCRIPT
Housekeeping Items3 PDH’s (By ACEC)ACEC & Tollway FTP Site
(Access Presentations)RestroomsSmokersSilence Cell PhonesQuestions
2
3
Publication Presenter
Introductions Mr. Matt Lehan
Opening Remarks Mr. Paul Kovacs
Tollway Standard Drawings Ms. Bridget Malinowski
Web Based Management System Mr. Dave Morris
Design Section Engineers Manual Mr. Jason Martin
Construction Managers Manual Mr. Nabil Fahoum
Structure Design Manual Mr. Art Nowak
Drainage Design Manual Mr. Edward Yousif
Break
4
Publication Presenter
Guidelines for Roadway Illumination Mr. John Farsatis
Roadway Design Criteria Mr. Tracy Borchardt
Traffic Barrier Guidelines Mr. Tracy BorchardtErosion and Sediment Control, Landscape Design Criteria Mr. Brian Smith
Signage and Markings Guidelines Ms. Bridget MalinowskiRoadway Traffic Control and Communications Manual Ms. Bridget Malinowski
C1- Galvanized Steel Plate Beam Guardrail
17
Modified Aggregate Shoulders Special Type C from 3” to 6” Depth.
Traffic Barrier TerminalsC6-Traffic Barrier Terminal Type T1 (Special)C7-Traffic Barrier Terminal Type T2C8-Traffic Barrier Terminal Type T5C9-Traffic Barrier Terminal Type T6C10-Traffic Barrier Terminal Type T6-BC12-Traffic Barrier Terminal Type T1-A
Modified Aggregate Shoulder Special Type C Depth from 3" to 6"
18
C6 Traffic Barrier Terminal Type T1(Special)
Traffic Barrier Terminal Type T1 (Special)
All steel post system
22
C12 Traffic Barrier Terminal Type T1-A (Special)
All steel post system
Traffic Barrier Terminal Type T1-A (Special)
23
C13- Concrete Median Barrier Transition at Bridge Piers
24
Increased Crash Wall HeightFrom 4’-6” to 5’-0”.
Extended Transition Taper Length From 28' to 30'.
D8-Raised Pavement Markers
RPM Detail C Revised for Placement with6” Dotted Line, 3’ Line 9’ GapOne-Way Crystal Marker1 each at 48’ Centers
32
E4- MOT Reverse Curve
36
Data shown for this reverse curve is based on a 45 MPH design and work zone speed limit.
Overhead Sign Structure, Span Type-Aluminum
Span Type- Redesigned For a 15’ Deep Sign Panel Over 75% of Span Length.
39
Overhead Sign Structure, Cantilever Type-Steel
Cantilever Type- Redesigned For 18’ Deep Sign Panel Over 75% of the Arm Length.
Maximum Panel Width Increased to 24’.
40
Overhead Sign Structure, Cantilever Type- Circular Foundation
Minimum Post outside diameter increased from 16” to 18”.Drilled shaft depth for all foundation types was increased.
41
H3-Wingwall Conduit Details
47
Revised cast iron junction box to stainless steel.Minimum size changed from 18” x 12” x 8” to 20” x 12” x 7”
M 19-22 Roadway Typical Sections-Groups
M19-Group A Mainline Roadways
M20-Group BRamp Roadways
M21-Group CDirectional
Ramp Roadways
M22-Group DGutter
Aggregate shoulder(With & without guardrail)
55
M 23-25 Roadway Typical Sections-Groups
M23-Group EMainline & Ramp
Fill & Cut Sections
M24-Group FGutter with
Single Slope Barrier
M25-Group GGutter with Noisewalls
56
Roadway Typical Sections-Groups
M 19-Group A Mainline Roadways
M 22-Group DGutter with
Guardrail
M 23-Group EMainline
Fill Sections
57