fast, accurate environmental testing...gc columns fast, accurate environmental testing using zebron...

8
GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more….. www.phenomenex.com/environmental

Upload: others

Post on 09-Jul-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fast, Accurate Environmental Testing...GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles

GC Columns

Fast, Accurate Environmental Testing

Using Zebron GC ColumnsFeaturing

• Pesticides• Diesel Range Organics• Semivolatiles• Dioxane• And more…..

www.phenomenex.com/environmental

Page 2: Fast, Accurate Environmental Testing...GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 min

Column: Zebron™ ZB-SemiVolatiles

Dimensions: 30 meter x 0.25 mm x 0.25 µm

Part No.: 7HG-G027-11

Injection: Split 10:1 @ 280 °C, 1 µL

Recommended Liner: Zebron PLUS Single Taper with Wool, 4 mm ID

Liner Part No.: AG2-0A11-05 (for Agilent® Systems)

Septum: AG0-4697 (PhenoRed™-400)

Inlet Seal: AG0-8620 (Easy Seals™)

Carrier Gas: Helium @ 1.4 mL/min (constant flow)

Oven Program: 40 °C for 0.5 min to 260 °C @ 40 °C/min to 295 °C @ 6 °C/min to 325 °C @ 25 °C/min for 2 min

Detector: MSD @ 340 °C; 45 – 450 amu

Sample: Analytes are 25 ppm in dichloromethane

Ap

p ID

205

82

Column: Zebron ZB-SemiVolatiles

Dimensions: 30 meter x 0.25 mm x 0.25 µm

Part No.: 7HG-G027-11

Injection: Splitless @ 250 °C, 1 µL

Recommended Liner: Zebron PLUS Single Taper with Wool, 4 mm ID

Liner Part No.: AG2-0A11-05 (for Agilent Systems)

Septum: AG0-4697 (PhenoRed-400)

Inlet Seal: AG0-8620 (Easy Seals)

Carrier Gas: Helium @ 1.6 mL/min (constant flow)

Oven Program: 40 °C for 0.66 min to 260°C @ 30 °C/min to 295 °C @ 6 °C/min to 325 °C @ 25 °C/min for 2 min

Detector: MSD @ 300 °C; 40-500 amu

Waste Water Matrix Extraction

3 4 5 6 7 8 9 10 11 12 13 14 15 16 min

Standard Curve at 25 µg/mL

3 4 5 6 7 8 9 10 11 12 13 14 15 16 min

Rapid and accurate chromatography

137 Analytes in 16 mins

TN-2039

Ap

p ID

230

75A

pp

ID 2

3071

See entire analyte list and technical note at www.phenomenex.com/search

Phenomenex l WEB: www.phenomenex.com

Semi-Volatile Organic Compounds

Bases, Acids, and Neutrals by GC-MS

Page 3: Fast, Accurate Environmental Testing...GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles

A) Zebron™ ZB-CLPesticides-1

B) Zebron ZB-CLPesticides-2

12

3

4

5

6 7

8 9 1011 12 13 14 1516

17 18

19

2021 22

0 2 4 6 8 10 min

0 2 4 6 8 10 min

1 2

3

4

56

7 89

1011

1213

141516

1718 19

20

21

22

Column: As listed

Dimensions: A) 30 meter x 0.32 mm x 0.32 µmB) 30 meter x 0.32 mm x 0.25 µm

Part No.: A) 7HM-G028-51B) 7HM-G029-11

Injection: Splitless @ 250 °C, 1 µL

Recommended Liner: Zebron PLUS Single Taper with Wool, 4 mm ID

Liner Part No.: AG2-0A11-05 (for Agilent® Systems)

Septum: AG0-4697 (PhenoRed™-400)

Sample: Analytes are 100 ng/mL in hexane

1. 2,4,5,6-TCMX (Surr) 2. a-BHC 3. g-BHC 4. b-BHC 5. d-BHC 6. Heptachlor 7. Aldrin 8. Heptachlor epoxide 9. trans-Chlordane 10. cis-Chlordane 11. Endosulfan I

12. 4,4’-DDE13. Dieldrin14. Endrin15. 4,4’-DDD16. Endosulfan II17. 4,4’-DDT18. Endrin aldehyde19. Methoxychlor20. Endosulfan sulfate21. Endrin ketone22. Decachlorobiphenyl (Surr)

Ap

p ID

241

25

Tap Water Extracted Ion Chromatogram at 25 ng/mL

Column: Zebron ZB-624

Dimensions: 30 meter x 0.25 mm x 1.4 µm

Part No.: 7HG-G005-27

Guard Column: 5 m Z-Guard™ (7AG-G000-00-GZ0)

Injection: Splitless @ 200 °C (hold 0.5 min), 2.0 µL

Ap

p ID

233

73A

pp

ID 2

3374

Ap

p ID

241

25

Recommended Liner: Zebron PLUS Single Taper Z-Liner™, 4 mm ID

Liner Part No.: AG2-0A13-05 (for Agilent Systems)

Septum: AG0-4697 (PhenoRed-400)

Inlet Seal: AG0-8620 (Easy Seals)

Carrier Gas: Helium @ 1.5 mL/min (constant flow)

Oven Program: 30 °C for 1 min to 90 °C @ 20 °C/min to 250 °C @ 50 °C/min

Detector: MSD @ 250 °C

Sample: 1. THF-d82. 1,4-dioxane-d83. 1,4-dioxane

Inlet Seal: AG0-8620 (Easy Seals™)

Carrier Gas: Hydrogen @ 3.5 mL/min (constant flow)

Oven Program: 85 °C for 0.5 min to 195 °C @ 45 °C/min for 3 min to 330 °C @ 30 °C/min

Detector: ECD @ 330 °C

1

2

3

4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8 6.0 6.2 6.4 6.6 6.8 7.0

4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8 6.0 6.2 6.4 6.6 6.8 7.0

4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8 6.0 6.2 6.4 6.6 6.8 7.0

Phenomenex l WEB: www.phenomenex.com

Chlorinated Pesticides using Hydrogen

1,4-Dioxane by GC-MS

Page 4: Fast, Accurate Environmental Testing...GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles

Diesel Fuel Hydrocarbons

Diesel Range Organics (DROs) by GC

0 2

12

4 6 8 10 12 min 0 2 4 6 8 10 12 14 min

1

2

Column: Zebron ZB-5HT Inferno™ ZB-1HT InfernoDimensions: 15 meter x 0.32 mm x 0.10 μm 15 meter x 0.32 mm x 0.25 μm

Part No.: 7EM-G015-02 7EM-G014-11

Injection: On-Column @ 63 °C, 0.1 μL Splitless @ 300 °C, 20 μL

Carrier Gas: Helium @ 2.7 mL/min (constant flow) Helium @ 2 mL/min (constant flow)

Oven Program : 60 °C to 375 °C at 25 °C/min 50 °C for 2 min to 320 °C @ 30 °C/min for 5 min

Detector: FID @ 400 °C FID @ 330 °C

Sample: Diesel Fuel was 200 ppm in Dichloromethane with Internal Standards at 50 ppm

1. Decane2. Tetracontane

Ap

p ID

161

47

Ap

p ID

181

53

Multi-Residue Pesticides by GC-MS

Ap

p ID

161

84

Column: Zebron™ ZB-MultiResidue™-1

Dimensions: 30 meter x 0.25 mm x 0.25 µm

Part No.: 7HG-G016-11

Injection: Splitless @ 260 °C, 1 µL

Recommended Liner: Zebron PLUS Single Taper with Wool, 4 mm ID

Liner Part No.: AG2-0A11-05 (for Agilent® Systems)

Septum: AG0-4697 (PhenoRed™-400)

Inlet Seal: AG0-8620 (Easy Seals™)

Carrier Gas: Helium @ 0.9 mL/min (constant flow)

Oven Program: 80 °C for 0.5 min to 150 °C @ 10 °C/min to 240 °C @ 4 °C/min to 320 °C @ 15 °C/min for 3 min

Detector: MSD @ 320 °C; 45-400 amu

Sample: Analytes are 1 ppm in dichloromethane

Recommended Liner: Zebron PLUS Single Taper, 4 mm ID

Liner Part No.: AG2-0A10-05

Septum: AG0-4696 (PhenoRed-400)

Inlet Seal: AG0-8620 (Easy Seals)

8 10 12 14 16 18 20 22 24 26 28 30 32 34

4

13-15

12

6-78

10

9 11

53

21

17

min

16

57

55

88

89

96

9798

99100101

102103

104105

108

107

106 109 112110,11190

91

92,93

94,95

5654

53

14 16 18 min 22 24 min

44-45

84

46-47

36,37 41-43 61 80-81

64-66

63

6059 62 67

68 7058

69 75 7985

71-74

77,7876 82

86 87

83

39

5052

49

51

48

20

21 24 25

26

273031

32

33

34

35

40

38

29

28

22

19

18

23

Zebron ZB-5HT Inferno Zebron ZB-1HT Inferno

TN-2021See entire analyte list and technical note at www.phenomenex.com/search

Phenomenex l WEB: www.phenomenex.com

Page 5: Fast, Accurate Environmental Testing...GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles

More GC columns, kits, and accessories available at

www.phenomenex.com/GC

Essentials Inferno™ Plus Unlimited

Please contact your Phenomenex representative for additional products and assistance.

BR

4977

0217

_W

Phenomenex l WEB: www.phenomenex.com

Drinking WaterTrihalomethanes by GC/MS with Selected Ion Monitoring (SIM) •Volatile Halogenated Organics by Purge & Trap GC/PID/ELCD •Volatile Aromatics and Unsaturated Organics by Purge & Trap GC •1,2-Dibromoethane (EDB), 1,2-Dibromo-3-chloropropane (DBCP), and 1,2,3-Trichloropropane (123TCP) by GC •Organohalide Pesticides & Aroclors by GC/ECD • •Nitrogen & Phosphorus Containing Pesticides by GC/NPD •Chlorinated Pesticides by GC/ECD •Ethylene Thiourea (ETU) by GC/NPD •2, 3, 7, 8-Tetrachlorodibenzo-p-dioxin by GC/HRMS •Chlorinated Acids by Liquid-Liquid Extraction, Derivatization and GC/ECD •Nitrosamines by Solid Phase Extraction (SPE) and GC/MS/MS with Large Volume injection •1,4-Dioxane by Solid Phase Extraction (SPE) and GC/MS with Selected Ion Monitoring (SIM) •Triazine Pesticides and their Degradates by GC/MS •Purgeable Organic Compounds by GC/MS •Semi-volatile Organic Chemicals by Solid Phase Extraction (SPE) and GC/MS •Phenols by Solid Phase Extraction (SPE) and GC/MS •Explosives and Related Compounds by Solid Phase Extraction (SPE) and GC/MS •Endothall by Aqueous Derivatization, Liquid-Solid Extraction, and GC/ECD •Chlorinated Solvents & Disinfection Byproducts by Liquid-Liquid Extraction and GC/ECD • •Haloacetic Acids and Dalapon by Liquid-Liquid Extraction, Derivatization, and GC/ECD •Carbonyl Compounds by Pentafluorobenzylhydroxylamine Derivatization and GC/ECD •

Solid WasteHalogenated Volatile Organics by GC/ELCD •Nonhalogenated Organics by GC •Aromatic Volatile Organics by GC/PID •Aromatic and Halogenated Volatiles by GC/PID or GC/ELCD •Acrolein and Acrylonitrile by GC/FID •Acrylamide by GC/ECD •Phenols by GC/ECD or GC/FID •Phthalate Esters by GC/ECD •Organochlorine Pesticides by GC/ECD • •Polychlorinated Biphenyls (PCBs) by GC/ECD • •Nitroaromatics and Cyclic Ketones by GC/ECD or GC/NPD •Explosives by GC/ECD •Polynuclear Aromatic Hydrocarbons by GC/FID •Chlorinated Hydrocarbons by GC/ECD •Aniline and Selected Derivatives by GC/NPD •Organophosphorus Pesticides by GC/FPD or GC/NPD •Chlorinated Herbicides by GC/ECD •Volatile Organic Compounds by GC/MS •Semi-volatile Organic Compounds by GC/MS •Polynuclear Aromatic Hydrocarbons (PAHs ) by SPME and GC/MS with Selected Ion Monitoring (SIM) •Polychlorinated Dibenzo-P-Dioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs) By HRGC/LRMS •Polychlorinated Dibenzo-P-Dioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs) By HRGC/LRMS •Semi-Volatile Organic Compounds by GC/FT-IR •Bis(2-chloroethyl) Ether and Hydrolysis Products by Direct Aqueous Injection GC/FT-IR •

Waste WaterPurgeable Halocarbons by Purge & Trap GC •Purgeable Aromatics by Purge & Trap GC •Acrolein & Acrylonitrile Purge & Trap GC •Phenols by GC/ECD •Phthalate Esters by GC/ECD •Nitrosamines by GC/NPD •Organochlorine Pesticides and PCBs by GC/ECD •Nitroaromatics & Isophorone by GC/FID and GC/ECD •Polynuclear Aromatic Hydrocarbons by GC/FID •Haloethers by GC/ECD •2,3,7,8-Tetrachlorodibenzo-p-dioxin by GC/MS •Chlorinated Herbicides by GC/ECD •Triazine Herbicides by GC/MS •Organophosphorus Pesticides by GC/MS •Purgeable Volatiles by Purge & Trap GC/MS •Base/Neutral and Acids by GC/MS •Tetra- through Octa-Chlorinated Dioxins and Furans by Isotope Dilution HRGC/HRMS •Polybrominated Diphenyl Esters (PBDEs) by HRGC/HRMS •Organohalide Pesticides, Organophosphorus Pesticides, and Phenoxy-Acid Herbicides by GC •Volatile Organic Compounds by Isotope Dilution GC/MS •Semi-volatile Organic Compounds by Isotope Dilution GC/MS •Organophosphorous Pesticides by GC/FPD •Phenoxy-Acid Herbicides by GC/ECD •Dazomet by GC/NPD •Pharmaceutical Volatile Organic Compounds by Purge & Trap GC or Isotope Dilution GC/MS • •Polychlorinated Biphenyl (PCB) Congeners by HRGC/HRMS •Pharmaceutical Manufacturing Volatile Organic Compounds by GC/FID •

ZB-6

24

ZB-5

0

ZB-W

AX

ZB-C

LPes

ticid

es -1

& 2

ZB-M

ultiR

esid

ue™- 1

& 2

ZB-S

emiV

olat

iles

ZB-1

plus

ZB-5

plus

ZB-W

AXpl

us™

ZB-5

HT

Select the GC Column for your Environmental Methods

Page 6: Fast, Accurate Environmental Testing...GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles

Ordering InformationZebron™ ZB-SemiVolatiles GC ColumnsZB-SemiVolatiles GC ColumnsLength (m) ID (mm) df (µm) Temp. Limits (°C) Part No.

15 0.25 0.25 -60 to 325/350 7EG-G027-1115 0.25 0.50 -60 to 325/350 7EG-G027-1720 0.18 0.18 -60 to 325/350 7FD-G027-0820 0.18 0.36 -60 to 325/350 7FD-G027-5330 0.25 0.25 -60 to 325/350 7HG-G027-1130 0.25 0.50 -60 to 325/350 7HG-G027-1760 0.25 0.25 -60 to 325/350 7KG-G027-11

Zebron ZB-1HT Inferno™ GC Columns

Length (m) ID (mm) df (µm) Temp. Limits (°C) Part No.5 0.53 0.10 -60 to 400/430 7AK-G014-0210 0.32 0.25 -60 to 400/430 7CM-G014-1115 0.25 0.10 -60 to 400/430 7EG-G014-0215 0.25 0.25 -60 to 400/430 7EG-G014-1115 0.32 0.10 -60 to 400/430 7EM-G014-0215 0.32 0.25 -60 to 400/430 7EM-G014-1115 0.53 0.15 -60 to 400 7EK-G014-0520 0.18 0.18 -60 to 400/430 7FD-G014-0830 0.25 0.10 -60 to 400/430 7HG-G014-0230 0.25 0.25 -60 to 400/430 7HG-G014-1130 0.32 0.10 -60 to 400/430 7HM-G014-0230 0.32 0.25 -60 to 400/430 7HM-G014-1130 0.53 0.15 -60 to 400 7HK-G014-05

Zebron ZB-5HT Inferno GC Columns

Length (m) ID (mm) df (µm) Temp. Limits (°C) Part No.15 0.25 0.10 -60 to 400/430 7EG-G015-0215 0.25 0.25 -60 to 400/430 7EG-G015-1115 0.32 0.10 -60 to 400/430 7EM-G015-0215 0.32 0.25 -60 to 400/430 7EM-G015-1115 0.53 0.15 -60 to 400 7EK-G015-0520 0.18 0.18 -60 to 400/430 7FD-G015-0830 0.25 0.10 -60 to 400/430 7HG-G015-0230 0.25 0.25 -60 to 400/430 7HG-G015-1130 0.32 0.10 -60 to 400/430 7HM-G015-0230 0.32 0.25 -60 to 400/430 7HM-G015-1130 0.53 0.15 -60 to 400 7HK-G015-0560 0.25 0.25 -60 to 400/430 7KG-G015-11

Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG-G015-11-B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages.

Page 7: Fast, Accurate Environmental Testing...GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles

Ordering Information

More GC columns, kits, and accessories available at

www.phenomenex.com/GC

If Zebron columns do not provide you with equivalent or better separations as compared to any other GC col-umn of the same phase and comparable dimensions, return the column with comparative data within 45 days for a FULL REFUND!

Zebron™ ZB-CLPesticides GC Columns ZB-CLPesticides-1 GC ColumnsLength (m) ID (mm) df (µm) Temp. Limits (°C) Part No.

30 0.25 0.25 40 to 320/340 7HG-G028-1130 0.32 0.32 40 to 320/340 7HM-G028-5130 0.32 0.50 40 to 320/340 7HM-G028-1730 0.53 0.50 40 to 320/340 7HK-G028-17

ZB-CLPesticides-2 GC ColumnsLength (m) ID (mm) df (µm) Temp. Limits (°C) Part No.

30 0.25 0.20 40 to 320/340 7HG-G029-1030 0.32 0.25 40 to 320/340 7HM-G029-1130 0.32 0.50 40 to 320/340 7HM-G029-1730 0.53 0.42 40 to 320/340 7HK-G029-16

Zebron ZB-MultiResidue™ GC ColumnsZB-MultiResidue-1 GC ColumnsLength (m) ID (mm) df (µm) Temp. Limits (°C) Part No.

20 0.18 0.18 -60 to 320/340 7FD-G016-08

30 0.25 0.25 -60 to 320/340 7HG-G016-11

30 0.32 0.25 -60 to 320/340 7HM-G016-11

30 0.32 0.50 -60 to 320/340 7HM-G016-17

30 0.53 0.50 -60 to 320/340 7HK-G016-17

ZB-MultiResidue-2 GC ColumnsLength (m) ID (mm) df (µm) Temp. Limits (°C) Part No.

30 0.25 0.20 -60 to 320/340 7HG-G017-1030 0.32 0.25 -60 to 320/340 7HM-G017-1130 0.53 0.50 -60 to 320/340 7HK-G017-17

Zebron ZB-624 GC Columns

Length (m) ID (mm) df (µm) Temp. Limits (°C) Part No.20 0.18 1.00 -20 to 260 7FD-G005-22

30 0.25 1.40 -20 to 260 7HG-G005-27

30 0.32 1.80 -20 to 260 7HM-G005-31

30 0.53 3.00 -20 to 260 7HK-G005-36

60 0.25 1.40 -20 to 260 7KG-G005-27

60 0.32 1.80 -20 to 260 7KM-G005-31

60 0.53 3.00 -20 to 260 7KK-G005-36

75 0.53 3.00 -20 to 260 7LK-G005-36

105 0.53 3.00 -20 to 260 7NK-G005-36Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG-G005-27-B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages.

Page 8: Fast, Accurate Environmental Testing...GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles

Fast, Accurate Environmental TestingUsing Zebron GC Columns

www.phenomenex.com/environmental

GC Columns

BR

4977

0217

_W

Terms and Conditions Subject to Phenomenex standard terms & conditions, which may be viewed at www.phenomenex.com/TermsandConditions. Trademarks Inferno, MultiResidue, Z-Liner, EasySeals, PhenoRed, 1plus, 5plus, WAXplus, Z-Guard, and Zebron are trademarks of Phenomenex. Agilent is a registered trademark of Agilent Technologies, Inc.© 2017 Phenomenex, Inc. All rights reserved.

www.phenomenex.comPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at [email protected]

Australiat: +61 (0)2-9428-6444 f: +61 (0)2-9428-6445

[email protected]

Austriat: +43 (0)1-319-1301f: +43 (0)1-319-1300

[email protected]

Belgiumt: +32 (0)2 503 4015 (French)t: +32 (0)2 511 8666 (Dutch)f: +31 (0)30-2383749

[email protected]

Canadat: +1 (800) 543-3681f: +1 (310) 328-7768

[email protected]

Chinat: +86 400-606-8099f: +86 (0)22 2532-1033

[email protected]

Denmarkt: +45 4824 8048f: +45 4810 6265

[email protected]

Finlandt: +358 (0)9 4789 0063f: +45 4810 6265

[email protected]

Francet: +33 (0)1 30 09 21 10 f: +33 (0)1 30 09 21 11

[email protected]

Germanyt: +49 (0)6021-58830-0f: +49 (0)6021-58830-11

[email protected]

Indiat: +91 (0)40-3012 2400f: +91 (0)40-3012 2411

[email protected]

Irelandt: +353 (0)1 247 5405f: +44 1625-501796

[email protected]

Italyt: +39 051 6327511f: +39 051 6327555

[email protected]

Luxembourgt: +31 (0)30-2418700 f: +31 (0)30-2383749

[email protected]

Mexicot: 01-800-844-5226f: 001-310-328-7768

[email protected]

The Netherlandst: +31 (0)30-2418700 f: +31 (0)30-2383749

[email protected]

New Zealandt: +64 (0)9-4780951f: +64 (0)9-4780952

[email protected]

Norwayt: +47 810 02 005f: +45 4810 6265

[email protected]

Puerto Ricot: +1 (800) 541-HPLCf: +1 (310) 328-7768

[email protected]

Spaint: +34 91-413-8613f: +34 91-413-2290

esp [email protected]

Swedent: +46 (0)8 611 6950f: +45 4810 6265

[email protected]

United Kingdomt: +44 (0)1625-501367f: +44 (0)1625-501796

[email protected]

USAt: +1 (310) 212-0555f: +1 (310) 328-7768

[email protected]

All other countries Corporate Office USA

t: +1 (310) 212-0555f: +1 (310) 328-7768

[email protected]