fall protection
DESCRIPTION
PPT for Safety ManagementTRANSCRIPT
![Page 1: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/1.jpg)
FALL PROTECTION
OSHA 29 CFR 1926 Subpart M (1926.500-503)
OSHA 29 CFR 1910 Subparts D, F, I(1910.23, 66, 67, 132)
1
)
![Page 2: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/2.jpg)
IMPORTANCE OF FALL PROTECTION
Each year, approximately 14 percent of fatal workplace injuries are caused by falls (Source: U.S. Dept. of Labor).
In construction, approximately 150-200 workers are killed annually due to falls (Source: OSHA).
2
![Page 3: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/3.jpg)
PPT-012-02
3
FALL PROTECTION REQUIREMENTS
General Industry (OSHA 1910) – must have in place if working at or above four (4) feet
Maritime (OSHA 1915) – must have in place if working at or above five (5) feet
Construction (OSHA 1926) – must have in place if working at or above six (6) feet
![Page 4: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/4.jpg)
DETERMINATION Employer should determine if
walking/working surfaces have structural strength and integrity to support employees safely.
Employer should verify employees are allowed to work only on surfaces having strength and integrity.
4
Is this safe?Definitely not!
![Page 5: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/5.jpg)
COMPETENT PERSON
One who is capable of identifying existing and predictable hazards in the surroundings or working conditions, which are unsanitary, hazardous or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.
5
![Page 6: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/6.jpg)
QUALIFIED PERSON
One who, by possession of a recognized degree, certificate or professional standing, or who by extensive knowledge, training and experience, has successfully demonstrated ability to solve or resolve problems relating to the subject matter, the work or the project.
6
PPT-012-02
![Page 7: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/7.jpg)
FACTORS AFFECTING TOTAL FALL DISTANCE Length of connecting means (i.e., lanyard length, use
of carabineers, snap hooks, etc.) Position and height of anchorage relative to work
platform/area (always keep above head whenever possible)
Position of attachment and “D-ring” slide on full body harness
Deployment of shock absorber (max. 42”) Movement in lifeline Initial position of worker before free fall occurs
7
![Page 8: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/8.jpg)
TYPES OF FALL PROTECTION SYSTEMS
Articulating manlifts provided with restraint systems and full body harness to anchor point below waist
Guardrails with toeboards Personal fall arrest systems: Anchor points (rated at 5,000 lbs.) Connectors (self-locking snap hooks) Retractable lanyard Full body harness Restraint line-lanyard Shock absorbing lanyard Rope grabs
8
![Page 9: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/9.jpg)
TYPES OF FALL PROTECTION SYSTEMS
Engineered life lines Warning lines
Safety nets Safety monitor systems
9
![Page 10: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/10.jpg)
RECOMMENDED LOCATIONS FOR FALL PROTECTION
All flat and low sloped roof locations when within 6’ of roof edge or for repair/maintenance
All exterior and interior platforms, catwalks, towers/antennas, etc.
All exterior and interior ladders above 20 feet
All mezzanine and balcony edges10
![Page 11: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/11.jpg)
RECOMMENDED LOCATIONS FOR FALL PROTECTION
All open excavations/pits
All tasks requiring use of manlifts
Scaffolding erection 10’ in height or greater
Tuck-pointing/chimney repair
Gymnasium (catwalks)
11
![Page 12: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/12.jpg)
PERSONAL FALL ARREST SYSTEMS
Full body harness used Should be inspected before each use by
employee, looking for: ▪ Deteriorated areas ▪ Excessive wear ▪ Bent hooks/rings ▪ Evidence of impact/damage
12
![Page 13: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/13.jpg)
PERSONAL FALL ARREST SYSTEMS
Connectors should be inspected to ensure they are drop-forged, pressed, formed steel or equivalent material.
Connectors should have corrosion-resistant finish, and surfaces/edges should be smooth.
D-rings and snap hooks should have minimum tensile strength of 5,000 lbs. and should be proof tested to 3,600 lbs.
Only shock absorbing or retractable lanyards should be used (keeps impact forces to the body at a minimum).
13
![Page 14: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/14.jpg)
PERSONAL FALL ARREST SYSTEMS
Nylon rope or nylon straps with locking snap hooks used for restraints.
Ensure unintentional disengagement of snap hooks cannot happen by either: Checking to see if snap hooks are correct size for
place they are to be connected, or Snap hooks are of the locking type.
14
![Page 15: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/15.jpg)
PERSONAL FALL ARREST SYSTEMS
Snap hooks should not be engaged as follows: ▫ Directly to webbing, rope, wire rope ▫ To each other ▫ To D-ring that has another snap hook attached ▫ To a horizontal lifeline• Maximum free-fall distance not to exceed 6 feet.• Consideration should be given to total fall
distance.
15
![Page 16: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/16.jpg)
CALCULATING TOTAL FALL DISTANCE
Total length of shock absorbing lanyard Height of person Location distance of D-ring from work surface
or platform
Always allow minimum of 6 feet clearance above ground, equipment, etc., at end of fall from fall-arrest point!
16
![Page 17: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/17.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Inspect body harness before each use: Closely examine all nylon webbing for burn
marks, tears, wear points, etc. Ensure no torn, frayed, broken fibers, pulled
stitches, frayed edges anywhere on harness. Examine D-ring to ensure no pits,
deterioration, cracks, excessive wear. Ensure buckles are not deformed/cracked and
operate correctly.
17
![Page 18: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/18.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Body harness before each use: Ensure all grommets (if present) are secure and
not deformed from fall/abuse. Ensure harness has no additional punched
holes. Ensure all rivets are tight and not deformed. Check tongue straps for excessive wear from
repeated buckling.
18
![Page 19: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/19.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Body harness: Annual inspection of harnesses should be
completed by competent person. Annual inspection should be documented. Harnesses should be stored hanging in
enclosed cabinet to protect from damage. Harnesses involved in fall should be destroyed.
19
![Page 20: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/20.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Lanyards/shock absorbing lanyards, before each use:
Check lanyard material for burns, cuts, rips, abrasions, kinks, knots, broken stitches, excessive wear.
Ensure snaphooks are not distorted. Check carabineer for excessive wear, distortion,
lock operation. Ensure all locking mechanisms seat & lock
properly. 20
![Page 21: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/21.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Lanyards/shock absorbing lanyards, before each use: Once locked, locking mechanism should prevent
hook from opening. Visually inspect shock absorber for signs of damage. Ensure points where lanyard attaches to snaphooks
are free of defects.
21
![Page 22: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/22.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Lanyards/shock absorbing lanyards: Should be inspected annually by competent
person. Annual inspection should be documented. Store lanyards/shock absorbing lanyards
hanging in enclosed cabinet to prevent damage.
Destroy all lanyards/shock absorbing lanyards involved in a fall.
22
![Page 23: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/23.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Snaphooks, before each use: Look for hook and eye distortions. Verify that there are no cracks, eye distortions,
pitted surfaces. Ensure keeper latch is not bent, distorted,
obstructed. Ensure keeper latch “seats” into “nose” without
binding. Ensure keeper spring securely closes keeper latch. Test locking mechanism to verify it’s working
properly.23
![Page 24: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/24.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Self-retracting lanyards, before each use: Visually inspect body to ensure no damage. Make sure all back nuts or rivets are tight. Make sure entire length of nylon strap is free
from cuts, abrasions, burns, kinks, knots, etc. Test unit by pulling sharply on lanyard to verify
locking mechanism is working properly. Return to manufacturer for annual inspection,
if required by manufacturer.24
![Page 25: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/25.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Self-retracting lanyards:
Monthly inspection should be conducted by competent person.
Service per manufacturer’s recommendations.
Inspect for proper function after every fall.
25
![Page 26: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/26.jpg)
INSPECTION OF FALL PROTECTION SYSTEMS
Tie-off adapters/anchorages: Inspect for integrity and attachment to solid
surface.
Annual inspection should be done by competent person and documented.
Destroy and replace after fall.
26
![Page 27: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/27.jpg)
Horizontal lifelines:
Before each use, check for structural integrity of line and anchors.
Annual inspection should be completed by competent person and documented.
27
INSPECTION OF FALL PROTECTION SYSTEMS
![Page 28: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/28.jpg)
Guardrails: Temporary systems =
Daily visual inspection by competent person. Complete structural by competent person.
Permanent systems = Annual inspection by competent person. Frequency of future inspections based
on conditions/controls present.
28
INSPECTION OF FALL PROTECTION SYSTEMS
![Page 29: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/29.jpg)
STORAGE & MAINTENANCE OF FALL PROTECTION EQUIPMENT
Never store in bottom of tool box, on ground or outside where exposed to elements.
Hang equipment in cool, dry place in a way so it retains its shape.
Always follow manufacturer’s recommendation for inspection.
Clean with mild, non-abrasive soap and hang to dry.
Never “force dry;” allow to air dry. Never use strong detergents for cleaning.
29
![Page 30: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/30.jpg)
STORAGE & MAINTENANCE OF FALL PROTECTION EQUIPMENT
Never store near excessive heat, chemicals, moisture or sunlight.
Never store in an area where exposure to fumes or corrosive elements may exist.
Avoid dirt and build-up on equipment. Never use equipment for any other purpose
other than personal fall arrest. Once exposed to fall, remove equipment from
service immediately.30
![Page 31: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/31.jpg)
ENGINEERED LIFELINE Lifeline systems must be designed and approved
by an engineer or qualified person. Lifeline systems must be engineered to have:
Appropriate anchorages Strength of line to hold X number of
people Line strength to aid in arrest of fall Durability to hold fallen worker until
rescused
31
![Page 32: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/32.jpg)
WARNING LINE SYSTEM
Should be erected no less than 6 feet from edge of roof.
Use stationary posts made of wood or metal. Should have wire or nylon rope and “caution
flags” strung from post to post; must withstand 16 pounds of force.
Entire perimeter of roof where work being performed must be guarded by warning line.
32
![Page 33: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/33.jpg)
FLOOR & WALL OPENINGS & HOLES(OSHA 29CFR1910.23)
Stairway Opening: Must be guarded by standard railing containing
top rail, mid-rail, posts. Height: 42” from upper surface of top rail to
floor/platform, etc. Top rail should be smooth-surfaced. Mid-rail should be halfway between top and
floor/platform, etc. Railing on all exposed sides, except entrance
to stairway.33
![Page 34: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/34.jpg)
FLOOR OPENINGS & HOLES
Ladder-way opening or platform:
Must be guarded with standard railing and toeboard.
Guarded on all exposed sides, except entrance to opening.
Entrance to have swinging gate or an offset to prevent direct access.
34
![Page 35: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/35.jpg)
FLOOR OPENINGS & HOLES
Hatchway & chute opening guarded by one of the following:
Hinged floor opening cover of standard strength with standard railings.
Cover must be closed when not in use or exposed side guarded with removable railings.
Removable railing and toeboard on not more than two sides of opening.
Fixed standard railings with toeboards on all other exposed sides.
35
![Page 36: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/36.jpg)
FLOOR OPENINGS & HOLES
Skylight opening/hole: Must be guarded by standard skylight screen or
fixed standard railing on all exposed sides.Pit and trapdoor opening (if infrequently used): Must be guarded by standard strength and
construction floor opening cover. When cover not in place, must be constantly
attended or protected on all exposed sides by removable standard railings.
36
![Page 37: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/37.jpg)
FLOOR OPENINGS & HOLES
Manhole opening: Must be guarded by standard manhole cover. Cover does not need to be hinged in place. When cover not in place, manhole must be
constantly attended or must be protected by removable standard railings.
Temporary floor opening: Must be guarded by standard railings or
constantly attended.
37
![Page 38: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/38.jpg)
WALL OPENINGS & HOLES
Wall opening with drop of more than 4 feet must be guarded by one of the following:
Rail Roller Picket fence Half door Equivalent barrier If exposure below to falling materials, must
have removable toeboard or equivalent. Grab handle must be provided on each side of
opening. 38
![Page 39: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/39.jpg)
WALL OPENINGS & HOLES
Chute openings with drop of 4 feet or more must be guarded by one of the following:
Rail Roller Picket fence Half door Equivalent barrier
39
![Page 40: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/40.jpg)
POWERED PLATFORMS, MANLIFTS, VEHICLE-MOUNTED WORK PLATFORMS
Employees on working platforms shall be protected by a personal fall arrest system.
System must meet requirements of OSHA 29 CFR 19 10.66, Appendix C, Section l.
40
![Page 41: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/41.jpg)
VEHICLE MOUNTED ELEVATING & ROTATING WORK PLATFORMS
41
Body harness should be worn and lanyard attached to boom or basket when working from an aerial lift.
![Page 42: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/42.jpg)
RAMPS, RUNWAYS, OTHER WALKWAYS
Employees must be protected from falling by guardrail systems.
42
![Page 43: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/43.jpg)
LEADING EDGE/ROOF
Employees who are constructing leading edges, working nearby or working on a roof must be protected against falls.
Protection can be provided by: guardrail systems safety net systems safety monitors personal fall arrest system
43
![Page 44: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/44.jpg)
FLAT ROOF
Flat roofs greater than 50 feet wide with work performed 6 feet or greater from edge: warning line & safety monitor system can be used.
If roof flat and less than 50 feet wide: competent person safety monitor may be used.
44
![Page 45: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/45.jpg)
LOW SLOPED ROOF
Employees engaged in roofing activities on low sloped roof (i.e., slight pitch) with unprotected sides must be protected from falling.
Can be protected by any of the following: Guardrail systems, safety net systems, personal fall
arrest system Combination warning line & guardrail system Combination warning line & safety net system Combination warning line & personal fall arrest Combination warning line & safety monitor Safety monitor alone (roofs 50’ in width only).
45
![Page 46: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/46.jpg)
STEEP ROOF
Employees working on a steep roof must be protected from falling.
Can be protected by: Guardrail systems with toeboards, Safety net systems, or Personal fall arrest systems.
46
![Page 47: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/47.jpg)
CONTROLLED ACCESS ZONES - CONSTRUCTION
Work area designated and clearly marked in which certain types of work (e.g., overhand bricklaying) may take place without the use of conventional fall protection systems.
Used to keep out workers other than those authorized to enter work areas from which guardrails have been removed.
Where there are no guardrails, masons are the only workers allowed in controlled access zones. 47
![Page 48: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/48.jpg)
Controlled access zones, when created to limit entrance to areas where leading edge work and other operations are taking place, must be defined by a control line or any other means that restrict access.
Control lines shall consist of ropes, wires, tapes or equivalent materials and supporting stanchions, and each must be: Flagged or otherwise clearly marked at not more
than 6-foot intervals with high-visibility material
48
CONTROLLED ACCESS ZONES - CONSTRUCTION
![Page 49: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/49.jpg)
Control lines must also:
Be rigged and supported so that the lowest point (including sag) is not less than 39” from the walking/working surface, and
Highest point is not more than 45” from walking/working surface (or more than 50” when overhand bricklaying operations are being performed)
49
CONTROLLED ACCESS ZONES - CONSTRUCTION
![Page 50: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/50.jpg)
Control lines must also: Be strong enough to sustain stress of not less than
200 pounds. Extend along the entire length of the unprotected
or leading edge. Shall be approximately parallel to the unprotected
or leading edge. Be connected on each side to a guardrail system
or wall.
50
CONTROLLED ACCESS ZONES - CONSTRUCTION
![Page 51: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/51.jpg)
When control lines are used, they shall be erected not less than 6’ or more than 25’ from the unprotected or leading edge (except when precast concrete members are being erected).
In the latter case, the control line is to be
erected not less than 6’ or more than 60’ (or half the length of the member being erected, whichever is less) from the leading edge.
51
CONTROLLED ACCESS ZONES - CONSTRUCTION
![Page 52: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/52.jpg)
EXCAVATIONS
Employees should be protected from falling by: Guardrail systems Fences Barricades
52
CAUTIONThis excavation may be unprotected!
![Page 53: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/53.jpg)
TRAINING
Employer must provide training to all affected employees.
Suggested topics: ▪ Overview of related OSHA regulations. ▪ Nature of fall hazards in workplace. ▪ Correct procedures for assembling, maintaining, disassembling and inspecting fall protection equipment to be used. ▪ Use and operation of guardrail, personal fall arrest, safety net, warning line and safety monitor systems, as well as other protection used.
53
![Page 54: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/54.jpg)
Suggested topics: ▪ Role of each employee in safety monitor system, when used. ▪ Limitations on use of mechanical equipment during roof work on low sloped roofs. ▪ Correct procedures for handling and storing materials and erection of overhead protection. ▪ Role of employees in fall protection plans. ▪ Understanding and following all components of the fall protection program. 54
TRAINING
![Page 55: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/55.jpg)
TRAINING RECORD
Employers should maintain written certification training records for affected employees.
Record should contain at least: Topic of training provided. Name or other identity of employee trained. Date(s) of training. Name (and signature recommended) of instructor who provided training.
55
![Page 56: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/56.jpg)
THE BOTTOM LINE
Provide fall protection when employees are working above 4’ in general industry, 5’ in maritime or 6’ in construction.
Fall protection should be a priority: safe actions save lives!
56
![Page 57: Fall Protection](https://reader033.vdocuments.mx/reader033/viewer/2022061608/5695d2291a28ab9b029958a8/html5/thumbnails/57.jpg)
QUESTIONS
57
PPT-012-02