failing on fouling. why should you?

Download Failing on fouling. Why should you?

Post on 26-May-2015

276 views

Category:

Engineering

0 download

Embed Size (px)

DESCRIPTION

Why failing on fouling? You can do better with these heat exchangers. Have a look it is free :-)

TRANSCRIPT

  • 1. 13-1-2015R & D Klarex Non Foulin Heat

2. R & D Klarex non-fouling heat exchanger The Fouling Killer 13-1-2015R & D Klarex Non Foulin Heat 3. Klarex non-fouling heat exchanger The work horses under the heat exchangers are the Shell & Tube Heat Exchangers. They are extremely reliable, and because of extensive research, predictable in their behaviour. Often they are the solution to a rather specific problem. Many thermo mechanical engineers delight in designing the optimal Shell & Tube Heat Exchanger for such special cases. And there are a lot of special cases in the world of heat exchangers that need a special solution. 13-1-2015R & D Klarex Non Foulin Heat 4. Klarex non-fouling heat exchanger One of the problems that often needs a special solution is the fouling of the heat exchanger. It occurs in al heat exchangers, but in some cases the fouling is so severe that for example three heat exchangers are required to guarantee continued operation. Then there is one in operation, one opened to be cleaned and one on standby for when the first one becomes fouled again. It leads to enormous expense for maintenance and a lot of over design is needed to compensate for the reduced heat exchange. The patented Klarex heat exchanger is a special design of a Shell & Tube Heat Exchanger, but with an important difference. 13-1-2015R & D Klarex Non Foulin Heat 5. Klarex non-fouling heat exchanger . The Klarex heat exchanger prevents fouling. No matter how long it is in use, the inside of the tubes stay clean. The Klarex heat exchanger does not need maintenance, does not use more energy and does its work uninterrupted and reliable for many years to come. The secret of the Klarex heat exchanger are the addition of metal anti-fouling particles. In the vertical pipe shell heat exchanger, metallic anti-fouling particles are continuously circulating with the fouling fluid. These metal particles prevent fouling of the pipe walls from the start. Furthermore, they also serve as turbulators for improving the heat exchange. 13-1-2015R & D Klarex Non Foulin Heat 6. Klarex non-fouling heat exchanger The Klarex heat exchanger prevents fouling. No matter how long it is in use, the inside of the tubes stay clean. The Klarex heat exchanger does not need maintenance, does not use more energy and does its work uninterrupted and reliable for many years to come. The secret of the Klarex heat exchanger are the addition of metal anti-fouling particles. In the vertical pipe shell heat exchanger, metallic anti-fouling particles are continuously circulating with the fouling fluid. These metal particles prevent fouling of the pipe walls from the start. Furthermore, they also serve as turbulators for improving the heat exchange. 13-1-2015R & D Klarex Non Foulin Heat 7. Klarex non-fouling heat exchanger A multiple path distribution system provides a uniform distribution of the particles across the pipes. Besides that, the system creates homogeneous mixing. Also, the quantity of the anti-fouling particles is adjustable. The anti-fouling Klarex heat exchangers are equipped with an external fall pipe for the particles. This has several advantages: - partical circulation is done with a lower downward particle speed, resulting in less wear of the fall pipe bottom; - both the rate of distribution, as well as the concentration and the circulation of particles in the fall pipes is easier to inspected and monitor with an internal fall pipe; 13-1-2015R & D Klarex Non Foulin Heat 8. Klarex non-fouling heat exchanger - there is no risk of unequal distribution of the particleflow in between the various parallel internal fall pipes; - when the heat exchanger is taken out of service, it is easy to remove most of the particles. This is advanteous for startup of operations of the heat exchanger, as well as inspection. The Klarex heat exchangers are suitable for many different applications, for they already have been tested extensively. 13-1-2015R & D Klarex Non Foulin Heat 9. Can we improve your energy ROI? Ask our colleague nl.linkedin.com/pub/bram-marcus/11/24b/34b or contact our company. 13-1-2015R & D Klarex Non Foulin Heat 10. Like to know more about our company? 13-1-2015R & D Klarex Non Foulin Heat Have a chat with Bronswerk people via our website or Visit our website: http://www.bronswerk.com/en/ 11. Meet us on LinkedIn. https://www.linkedin.com/company/bronswerk-heat- transfer/products?trk=top_nav_products 13-1-2015R & D Klarex Non Foulin Heat Exchanger Join our community! 12. Join our community! Conversate with us on Facebook. http://www.facebook.com/Bronswerk. R & D Klarex Non Foulin Heat Exchanger 13-1-2015 13. Join our community! Follow us on Twitter. https://twitter.com/bronswerk 13-1-2015R & D Klarex Non Foulin Heat Exchanger 14. Share our content? http://www.slideshare.net/Bronswerk 13-1-2015R & D Klarex Non Foulin Heat Exchanger Join our community! 15. Thank you for your attention! 13-1-2015R & D Klarex Non Foulin Heat