factory in arenys de mar (spain) technical features · cop - 3.41 3.21 3.41 3.21 3.01 3.35 3.21...

2
TECHNICAL FEATURES MODEL 1402.2 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 5002.4 6002.4 7002.4 Nominal cooling capacity kW 46.1 52.4 65.1 79.1 86.2 113.6 125.3 134.8 171 200 218.5 Absorbed power kW 16.4 20.1 21.6 28.1 33 39.5 44.4 49.9 53.9 69.1 77.8 EER - 2.81 2.61 3.01 2.81 2.61 2.88 2.82 2.70 3.17 2.90 2.81 Energy classification (2) - B C A B C B B C A B B Nominal heating capacity kW 46.8 53.9 65 80.4 89.1 119.1 132.7 143 169.8 205.7 226.7 Absorbed power kW 13.7 16.8 19.1 25 29.6 35.6 41.4 45.8 49.8 63.3 70.6 COP - 3.41 3.21 3.41 3.21 3.01 3.35 3.21 3.12 3.41 3.25 3.21 Energy classification (2) - A B A B C B B C A B B Power supply (50 Hz) V 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N Nominal supply air flow m 3 /h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000 28,500 34,000 37,000 Available static pressure Pa 100 100 125 125 125 150 150 150 175 175 175 Dimensions (length x width x height) mm 2.886 x 2.219 x 1.240 2.886 x 2.219 x 1.240 2.886 x 2.219 x 1.240 2.886 x 2.219 x 1.240 2.886 x 2.219 x 1.240 3.900 x 2.219 x 1.900 3.900 x 2.219 x 1.900 3.900 x 2.219 x 1.900 4.330 x 2.219 x 2.240 4.330 x 2.219 x 2.240 4.330 x 2.219 x 2.240 Net weight kg 944 975 1,023 1,043 1,072 1,594 1,704 1,721 2,454 2,624 2,628 MODEL 1402.2 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 5002.4 6002.4 7002.4 Nominal cooling capacity (1) kW 64.1 71.1 87.4 103.5 116.4 152 164.8 178.4 223.7 270.2 292.7 Recovery cooling capacity kW 17.7 18.2 20.8 21.4 25.3 34.8 35.4 38.4 46.3 58.7 66.9 Main circuits cooling capacity kW 46.4 529 66.9 82.1 91.1 117.3 129.5 140.1 177.5 211.5 225.8 Absorbed power kW 20.3 23.9 26.8 34.4 41.6 49.7 55.7 63.1 66 87 97.4 EER - 3.16 2.97 3.26 3.01 2.81 3.06 2.96 2.83 3.39 3.11 3.01 Energy classification (2) - A B A A B A B B A A A Nominal heating capacity (1) kW 67.4 76.8 89.2 106 120.8 163.8 177.6 193.5 223.9 278.9 311.8 Recovery heating capacity kW 17.8 18.4 20.7 21.6 25.3 41 41.4 46.1 45.6 58.5 78 Main circuits heating capacity kW 49.6 58.4 68.5 84.4 95.5 122.8 136.2 147.4 178.2 220.4 233.7 Absorbed power kW 17.1 19.9 22.7 28.2 34.4 42.4 48.6 54.8 56.1 73.6 84.1 COP - 3.94 3.85 3.92 3.76 3.51 3.86 3.66 3.53 3.99 3.79 3.71 Energy classification (2) - A A A A A A A A A A A Power supply (50 Hz) V 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N Nominal supply air flow m 3 /h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000 28,500 34,000 37,000 Available static pressure Pa 100 100 125 125 125 150 150 150 175 175 175 Dimensions (length x width x height) mm 3,968 x 2,219 x 1,240 3,968 x 2,219 x 1,240 3,968 x 2,219 x 1,240 3,968 x 2,219 x 1,240 3,968 x 2,219 x 1,240 5,845 x 2,219 x 1,900 5,845 x 2,219 x 1,900 5,845 x 2,219 x 1,900 6,300 x 2,219 x 2,240 6,300 x 2,219 x 2,240 6,300 x 2,219 x 2,240 Net weight kg 1,315 1,353 1,417 1,445 1,531 2,373 2,519 2,549 3,317 3,456 3,491 STD RCF (1) For an air renovation flow of 90%. (2) According to EUROVENT classification Note: KUBIC VRC equipment has the same capacity as STDs and the same dimensions as RCFs. For the GB modules, query configuration and available capacity. COMPACT, LIGHTWEIGHT AND MODULAR 2017 RANGE A DIFFERENT ROOFTOP ANDALUCÍA ARAGÓN ASTURIAS BALEARES CANTABRIA CASTILLA-LA MANCHA VALENCIA CASTILLA Y LEÓN CATALUÑA EXTREMADURA GALICIA LA RIOJA MADRID MURCIA NAVARRA PAÍS VASCO Vilanova i la Geltrú Arenys de Mar Factory in Vilanova i la Geltrú (Spain) Factory in Arenys de Mar (Spain) NEW NEW HIPLUS AIRE ACONDICIONADO S.L. Masia Torrents, 2 Tel. +34 938 934 912 Fax +34 938 939 615 08800 Vilanova i la Geltrú Barcelona, Spain www.hitecsa.com www.adisaheating.com

Upload: others

Post on 02-Feb-2021

9 views

Category:

Documents


0 download

TRANSCRIPT

  • TECHNICAL FEATURES

    MODEL 1402.2 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 5002.4 6002.4 7002.4

    Nominal cooling capacity kW 46.1 52.4 65.1 79.1 86.2 113.6 125.3 134.8 171 200 218.5

    Absorbed power kW 16.4 20.1 21.6 28.1 33 39.5 44.4 49.9 53.9 69.1 77.8

    EER - 2.81 2.61 3.01 2.81 2.61 2.88 2.82 2.70 3.17 2.90 2.81

    Energy classification (2) - B C A B C B B C A B B

    Nominal heating capacity kW 46.8 53.9 65 80.4 89.1 119.1 132.7 143 169.8 205.7 226.7

    Absorbed power kW 13.7 16.8 19.1 25 29.6 35.6 41.4 45.8 49.8 63.3 70.6

    COP - 3.41 3.21 3.41 3.21 3.01 3.35 3.21 3.12 3.41 3.25 3.21

    Energy classification (2) - A B A B C B B C A B B

    Power supply (50 Hz) V 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N

    Nominal supply air flow m3/h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000 28,500 34,000 37,000

    Available static pressure Pa 100 100 125 125 125 150 150 150 175 175 175

    Dimensions(length x width x height) mm

    2.886 x 2.219 x 1.240

    2.886 x 2.219 x 1.240

    2.886 x 2.219 x 1.240

    2.886 x 2.219 x 1.240

    2.886 x 2.219 x 1.240

    3.900 x 2.219 x 1.900

    3.900 x 2.219 x 1.900

    3.900 x 2.219 x 1.900

    4.330 x 2.219 x 2.240

    4.330 x 2.219 x 2.240

    4.330 x 2.219 x 2.240

    Net weight kg 944 975 1,023 1,043 1,072 1,594 1,704 1,721 2,454 2,624 2,628

    MODEL 1402.2 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 5002.4 6002.4 7002.4

    Nominal cooling capacity (1) kW 64.1 71.1 87.4 103.5 116.4 152 164.8 178.4 223.7 270.2 292.7

    Recovery cooling capacity kW 17.7 18.2 20.8 21.4 25.3 34.8 35.4 38.4 46.3 58.7 66.9

    Main circuits cooling capacity kW 46.4 529 66.9 82.1 91.1 117.3 129.5 140.1 177.5 211.5 225.8

    Absorbed power kW 20.3 23.9 26.8 34.4 41.6 49.7 55.7 63.1 66 87 97.4

    EER - 3.16 2.97 3.26 3.01 2.81 3.06 2.96 2.83 3.39 3.11 3.01

    Energy classification (2) - A B A A B A B B A A A

    Nominalheating capacity (1) kW 67.4 76.8 89.2 106 120.8 163.8 177.6 193.5 223.9 278.9 311.8

    Recovery heating capacity kW 17.8 18.4 20.7 21.6 25.3 41 41.4 46.1 45.6 58.5 78

    Main circuits heating capacity kW 49.6 58.4 68.5 84.4 95.5 122.8 136.2 147.4 178.2 220.4 233.7

    Absorbed power kW 17.1 19.9 22.7 28.2 34.4 42.4 48.6 54.8 56.1 73.6 84.1

    COP - 3.94 3.85 3.92 3.76 3.51 3.86 3.66 3.53 3.99 3.79 3.71

    Energy classification (2) - A A A A A A A A A A A

    Power supply (50 Hz) V 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N 400.3 + N

    Nominal supply air flow m3/h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000 28,500 34,000 37,000

    Available static pressure Pa 100 100 125 125 125 150 150 150 175 175 175

    Dimensions (length x width x height) mm

    3,968 x 2,219 x 1,240

    3,968 x 2,219 x 1,240

    3,968 x 2,219 x 1,240

    3,968 x 2,219 x 1,240

    3,968 x 2,219 x 1,240

    5,845 x 2,219 x 1,900

    5,845 x 2,219 x 1,900

    5,845 x 2,219 x 1,900

    6,300 x 2,219 x 2,240

    6,300 x 2,219 x 2,240

    6,300 x 2,219 x 2,240

    Net weight kg 1,315 1,353 1,417 1,445 1,531 2,373 2,519 2,549 3,317 3,456 3,491

    STD

    RCF

    (1) For an air renovation flow of 90%.(2) According to EUROVENT classification

    Note: KUBIC VRC equipment has the same capacity as STDs and the same dimensions as RCFs. For the GB modules, query configuration and available capacity.

    COMPACT, LIGHTWEIGHT AND MODULAR

    2017 RANGE

    A DIFFERENTROOFTOP

    ANDALUCÍA

    ARAGÓN

    ASTURIAS

    BALEARES

    CANTABRIA

    CASTILLA-LA MANCHAVALENCIA

    CASTILLA Y LEÓNCATALUÑA

    EXTREMADURA

    GALICIA

    LA RIOJA

    MADRID

    MURCIA

    NAVARRA

    PAÍS VASCO

    Vilanova i la Geltrú

    Arenys de Mar

    Factory in Vilanovai la Geltrú (Spain)

    Factory in Arenys de Mar (Spain)

    NEW

    NEW

    HIPLUS AIRE ACONDICIONADO S.L.

    Masia Torrents, 2Tel. +34 938 934 912Fax +34 938 939 615

    08800 Vilanova i la GeltrúBarcelona, Spain

    www.hitecsa.comwww.adisaheating.com

  • ROOFTOP TYPE UNITSWITH AXIAL FANS

    Basic equipment (return air only)with standard TH TUNE thermostat(optional PGD and MINI PGD)

    KUBIC STDStandard Unit

    Available modules

    The thermodynamic heat recovery module includes an additional refrigerating circuit which operates at high cooling efficiency. This circuit takes advantage of extract air flow air to recover part of the wasted heat. Through heat recovery it can increase both the capacity and the nominal and seasonal efficiencies of the unit.

    KUBIC RCF Thermodynamic heatrecovery module

    Free-cooling thermal or enthalpy control EC supply air plug fan G4 gravimetric filter F6 to F9 class opacimetric filters

    (in addition to G4 or Fx+Fy) Air quality sensor Dirty filters detector Motor protection Motors for overpressure Back-up heating coils Auxiliary heating coils Ambient temperature or wall-mounted sensor Scheduling function and connection

    * Inquire for all available options.

    With MANY OPTIONAL FEATURESWith MULTIPLE CONFIGURATIONSMaximum adaptability to existing projects

    G4, F6 to F9 combinable filters

    ThermostatMINI PGD

    * When compared to an equivalent model from other manufacturers. Ref. model 3002.2 with 87 kW

    LESS WEIGHT

    LESS HEIGHT

    LESS VOLUME

    -12% WEIGHT

    -37% HEIGHT

    -34% VOLUME

    COMPACT, LIGHTWEIGHT, MODULARAND HIGHLY ENERGY EFFICIENT

    A DIFFERENTROOFTOP

    The units of the KUBIC series are autonomous rooftop units that are specially designed for installation on rooftops, roof terraces or in any other outdoor location. There are different models with the option of cooling only or heat pump.

    Its Extra-compact modular design gives a high versatility for both installation and operation, whatever the project is. Units will be delivered completely finished and tested, with the appropriate load of R-410A refrigerant for their correct operation.

    Scroll type compressors

    PGD Thermostat

    The VRC module allows to manage different discharge air flow renovation percentages. The assembly of three dampers also allowsfreecooling with either thermal, enthalpy or thermo- enthalpy management.

    KUBIC VRC Module with centrifugalreturn fan

    PLUGFAN FANS Greater energy efficiency Lower consumption Quieter High pressures available Low maintenance cost

    CONFIGURATION EXAMPLES

    SUPPLY / RETURN SUPPLY/ NEW AIR

    Any combination of supply and return is valid, taking into account that there can only be one supply and one return.

    Any combination of supply and return is valid, taking into account that there can only be one supply and one return and one fresh air damper.

    SUPPLY / FREECOOLING

    Any combination of supply and freecooling configuration is valid, taking into account that there can only be one supply and two dampers.

    Recommended optional features

    Environmentally friendly refrigerant

    The module with gas burneris specially designed for the climate control of large areas in the industrial and commercial sectors,as well as for areas with extremely low temperatures.

    KUBIC GB Module with gas burner

    (Standard for RCF, VRC and GB modules)

    ThermostatTH TUNE

    F: fresh air damper / R: return air damper. *For specific configurations, consult us.

    Valid configurations for models up to 4502. Other configurations, please inquire.

    SUPPLY CONFIGURATIONS

    Lower Upper Side

    Lower Upper Left side Upper frontRight side Lower front

    Lower Upper Right side Upper frontLeft side Lower front

    RETURN CONFIGURATIONS

    FRESH AIR DAMPER CONFIGURATIONS

    FREE-COOLING CONFIGURATIONS

    R

    R R

    R RF

    FF

    F

    F

    Lower + upper front Upper + lower front Upper + lower Front Side

    NEWMODELS

    5002.4 x 6002.4 x 7002.4

    COMPETITIVE ADVANTAGES• Triple return filtering.• Double circuit with tandem compressors in order to

    improve the efficiency of the equipment for partial loads

    • Option for high pressure EC plug fan

    • The same configuration options as the other circuits of the range: Freecooling double dampers, VRC Module, RCF Module and GB Module

    BIG