eyefill – a caring decision - bausch.se · • storage 2–25°c • comfortable retention in the...
TRANSCRIPT
EYEFILL® – A CARING DECISION
EYEFILL® D.C.
D I S P E R S I V E C O H E S I V EEYEFILL® S.C.S U P R E M E C O H E S I V E
The new sTandard viscoelasTic
The viscoadapTive viscoelasTic
dispersive hpMc viscoelasTic
highly cohesiveviscoelasTic
includes Two syringes of viscoelasTics
EYEFILL® vISCOElAStICS wERE DEvElOpED tO mEEt thE DEmANDS Of All SuRGICAl EvENtuAlItIES
EYEFILL® S.C.S U P R E M E C O H E S I V E
• the optimal viscoelastic
for standard cataract
surgery
• favourable cell protection
combined with stabilizing
properties
• perfect stabilization
• Space creation
• Iris prolaps
• flat anterior chamber
EYEFILL® D.C.
D I S P E R S I V E C O H E S I V E
• for standard cataract
surgery when extra cell
protection is required
• Atraumatic movement of
tissue structures
• Guarantees excellent
cell protection
• Contact agent for vitreo-
surgical lenses, fundos-
copy and
gonioscopy
• Offers the choice between a
dispersive and
a cohesive viscoelastic
• for soft shell operating
technique
IndIcatIons:
• Storage 2–25°C• Comfortable retention in the anterior chamber
and capsular bag• Indicated in case of flat anterior chambers and • iris prolapse • Steam sterilized for inner and outer sterility• Biofermentative hyaluronic acid
• 2% biofermentative hyaluronic acid• viscosity (0.1 s-1): 400,000 mpa·s• volume: 0.9 ml
spEcIFIcatIon
Raw matERIaL and stERILItY
• Raw material: biofermentative hyaluronic acid• Sterility: steam sterilization • Inner and outer sterility guaranteed
(product ready to use in the operating theatre)
EYEfIll® S.C. can be classified as a highly-viscous, cohesive, viscoelastic liquid. hence, it stabilizes and pressurizes the anterior chamber and creates a lot of space for convenient surgical intervention.
stoRaGE tEmpERatURE: 2-25°c
• particular performance in standard cataract situations• Eminent maintenance of the anterior chamber and
capsular bag• Excellent cell-protective potential• Steam autoclaved for inner and outer sterility• Biofermentative hyaluronic acid
• 1.4 % biofermentative hyaluronic acid• viscosity (0.1 s-1): 120,000 mpa·s• filling volume: 1.0 ml
spEcIFIcatIon
Raw matERIaL and stERILItY• Raw material: biofermentative hyaluronic acid• Sterility: final steam sterilization guarantees
inner and outer sterility • product is ready to use in the operating theatre
EYEfIll® C. is the viscous, cohesive, viscoelas-tic liquid of choice for standard cataract surgical procedures. thanks to its novel state-of-the-art formulation, EYEfIll® C. combines constant stabilization of the anterior chamber and the capsular bag as well as securing of protection of the sensitive ophthalmic tissues.
stoRaGE tEmpERatURE: 2-8°c
stoRaGE tEmpERatURE: 2-8°c
Due to its particular viscoelastic properties EYEfIll® D.C. maintains a constant deep anterior chamber and protects the corneal endothelium throughout the whole cataract surgery.
• Comfortable retention in the anterior chamber and capsular bag
• Excellent protection of intraocular tissue• Biofermentative hyaluronic acid and
ultra-pure hpmC • Steam sterilized for inner and outer sterility
• 1.37% biofermentative hyaluronic acid + 0.57% hpmC• viscosity (0.1 s-1): 100,000 mpa·s• volume: 1 ml
spEcIFIcatIon
Raw matERIaL and stERILItY• Raw material: biofermentative hyaluronic acid
and ultra-pure hpmC• Sterility: Inner and outer sterility guaranteed
(product ready to use in the operating theatre)
stoRaGE tEmpERatURE: 2-8°c
• Excellent cell protection • perfect adjuvant for fundoscopy and gonioscopy• Steam sterilized for inner and outer sterility
• 2% hpmC • viscosity (5 s-1): 4,000 mpa·s • volume: 2.5 ml • Inner and outer sterility guaranteed
spEcIFIcatIon
Raw matERIaL and stERILItY• Raw material: hpmC • Inner and outer sterility guaranteed (product ready to use
in the operating theatre)
EYEfIll® h.D. can be used during cataract surgeries and as an adjuvant during fundo-scopy and gonioscopy. It may also be used as a coupling fluid for diagnostic and therapeutic contact lenses. Due to its low-viscous, disper-sive features EYEfIll® h.D. provides the most excellent cell protection and prevents endothelial cell damage during surgery.
stoRaGE tEmpERatURE: max. 25°c
stoRaGE tEmpERatURE: max. 25°c
EYEfIll® m.B. offers surgeons the choice between two viscoelastic fluids of different viscosities. EYEfIll® m.B. maintains constant stabilisation of the anterior chamber and capsular bag and assures notable protection of the sensitive corneal endothelium.
• Includes two viscoelastic fluids for all needs during cataract surgery
• mEGA I and BIO II are completely miscible and compatible
• Optimal maintenance of the anterior chamber and capsular bag
• Excellent cell protection potential• Steam autoclaved for inner and outer sterility• Biofermentative hyaluronic acid
spEcIFIcatIon mEGa 1
Raw matERIaL and stERILItY• Raw material: biofermentative
hyaluronic acid• Sterility: final steam sterilisation guarantees
inner an outer sterility (product is ready to use in the operating theatre)
stoRaGE tEmpERatURE: 2-8°c
• 1.8 % biofermentative hyaluronic acid• viscosity (0.1 s-1): 100,000 mpa.s• filling volume: 0.55 ml
• 1.4 % biofermentative hyaluronic acid• viscosity (0.1 s-1): 80,000 mpa.s• filling volume: 0.8 ml
spEcIFIcatIon BIo II
min.
up to
HPMC 2%
Just 1 drop provides corneal hydration for up to 20 min
with significantly greater optical clarity (mean grade 1.0 vs. 2.0; p=0.03) 1)
Corneal hydration that lets you stay focused on the surgery
1) Reference: Chen Y-A, Hirnschall N and Findl O. Corneal wetting with a viscous eye lubricant to maintain optical clarity during cataract surgery. J Cataract Refract Surg. In press
Bausch + Lomb nordic aB sweden: 08 616 95 70, norway: 800 104 40, denmark: 808 809 90, Finland 0800 118 011
EYf/ENG/1505/0008