external air heater manual - nordsonemanuals.nordson.com/adhesives/english_manuals/107026.pdf ·...
TRANSCRIPT
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Nordson Corporation welcomes requests for information, comments and inquiries about its products.
Address all correspondence to
Nordson Corporation11475 Lakefield DriveDuluth, GA 30136
Notice
This is a Nordson Corporation publication which is protected by copyright. Original copyright date 1995. No partof this document may be photocopied, reproduced, or translated to another language without the prior writtenconsent of Nordson Corporation. The information contained in this publication is subject to change without
notice.
Trademarks
AquaGuard, Blue Box, Control Coat, Equi Bead, FloMelt, FoamMelt, FoamMix, Helix, Hot Shot, Hot Stitch,Meltex, MicroSet, MultiScan, Nordson, the Nordson logo, OmniScan, Porous Coat, Posi-Stop, RBX, Sure-Bond,
UniScan, UpTime, and Versa-Spray are registered trademarks of Nordson Corporation.
BetterBookSM, CF, Controlled Fiberization, Easy-Screen, Fibermelt, Flo-Tracker, PrintGuard, and Package ofValues are trademarks of Nordson Corporation.
Never Seez is a registered trademark of Bostik Corporation.
Table of Contents i
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Table of Contents
1. Safety Precautions 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. Description 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External Air Heater Operation 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3. Installation Procedures 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing a Single-Channel Air Heater for a 2000 Applicator 6. . . . .
Installing a Single-Channel Air Heater for a2300, 3000, or 6000 Applicator 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing a Dual-Channel Air Heater for a2300, 3000, or 6000 Applicator 10. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alternative Installations 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4. Operation Procedures 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting Up for a Single-Channel External Air Heater 14. . . . . . . . . .
Setting Up for a Dual-Channel External Air Heater 15. . . . . . . . . . . .
Shutting Down the External Air Heater 16. . . . . . . . . . . . . . . . . . . . . .
5. Troubleshooting 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6. Parts 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Parts List 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7. Illustrated Parts List 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 2000 Single-Channel Air Heater Parts List 25. . . . . . . . . . . . .
Models 2300, 3000, or 6000Single-Channel Air Heater Parts List 29. . . . . . . . . . . . . . . . . . . . . . .
Models 2300, 3000, or 6000 Dual-ChannelAir Heater Parts List 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 2000 Applicator 5-Wire Cordset 36. . . . . . . . . . . . . . . . . . . . . .
Models 2300, 3000, or 6000 Applicator Cordset 38. . . . . . . . . . . . . .
Model 3000 or 6000 Air Heater Cordset 40. . . . . . . . . . . . . . . . . . . . .
Supplementary Equipment 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External Air Heater Manual
Table of Contentsii
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
External Air Heater Manual 1
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
External Air Heater Manual
WARNING: Allow only qualified personnel to perform thefollowing tasks. Observe and follow the safety instructions inthis document and all other related documentation.
WARNING: Hot! Risk of burns. Hot melt material may bereleased under pressure. Wear heat-protective clothing, safetygoggles, and heat-protective gloves.
WARNING: Turn off the main circuit breaker (or maindisconnect switch) and disconnect and lock out input power tothe melter. Failure to disconnect external power to the melterpresents a serious shock hazard.
The Nordson CF 200 Controlled Fiberization gun applies a spiral patternof hot melt material onto a substrate when triggered by an electrically-controlled solenoid valve. Since this gun does not contain a heated airmanifold, the gun requires an external air heater (or heated hose) to heatthe air that forces the adhesive into the spiral pattern. This manualcovers the external air heater.
In guns with four or more CF 200 modules, spray air is delivered throughtubing connected to a separate single-channel or dual-channel air heater.The single-channel heater controls the temperature for one heated airsupply. A dual-channel heater controls the temperature for two heatedair supplies.
1. Safety Precautions
2. Description
Introduction
External Air Heater Operation
4204103
HEATER
RTD
HEATER
External Air Heater Manual2
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Fig. 1 2000 Single-Channel Air Heater Wiring Diagram
4204104
HEATER
RTD
HEATER
1234
5678
9101112
GND
Fig. 2 2300/6000 Single-Channel Air Heater Wiring Diagram
Specifications
External Air Heater Manual 3
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204105
CB120 AMPL1
L2
230VAC10 50/60 HZ3400 WATTS
1
2
MAINPOWER
3A
CHANNEL 1SWITCHTEMP
CHANNEL 1HEATERRELAY
CHANNEL 1HEATER
CHANNEL 1HEAT
LIMITER
LT
SOL1
33B 3C
SW1
75
6
1CR
CTR 1JUMPER
JUMPER
8 4 5
616 11 9
8 7
RTD 1
3D 3E
CHANNEL 1SOLENOID
9
10
11
12
OTC 1
1CR
HTR1
1CR
1 THS
SOL2
3F 3G
SW2
2214
15
2CR
CTR 2JUMPER
JUMPER
8 4 5
616 11 9
17 16
RTD 2
3H 3J
18
19
20
21
OTC 2
2CR
HTR2
2CR
2 THS
4A 4 4B 4C 4D 4E 4F 4G
SOL = SOLENOIDHTR = HEATEROTC = OVERTEMPERATURE CONTROLLERRTD = RESISTANCE TEMPERATURE DETECTORCTR = CONTROL
THS = THERMOSTATTHG = THERMOSTAT (GUN)CB = CIRCUIT BREAKERCR = CONTROL RELAYLT = LIGHT
Fig. 3 Dual-Channel Air Heater Schematic
Specifications (contd.)
External Air Heater Manual4
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204106
LEADS
4G21
(933314)
1--CR (P/N 860307) 2--CR (P/N 860307)
3D 3H
3C 3G9 11 10 18 20 19 156
12GND
SOL--2(P/N 901132)
G1230 VOLTS 24,25
224E25
TB1
1123A3C3F3J4A4C4E
4G
3B3E3G
4B4D4F
12GND
SOL--1(P/N 901132)
234G24
11 20
OTC--2(271838)
OTC--1(271838)
4D12
CB13A34A4
1
2
LT
(P/N 939177)
34
RTD2
LEADS
RTD116
17
7
8
3J
3E
21
12
HEAT
BARRIER
2 THS (P/N 937281)
1 THS (P/N 937281)
RTD 2(P/N 939305)
RTD 1(P/N 939305)
HEATER 2 (P/N 245636)
HEATER 1 (P/N 245636)
1819
10 9
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
CTR--1(P/N 803789)
6 4C 54H
7 8
8A
3B 5,23SW--1
(P/N 860300)
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
CTR--2(P/N 803789)
16 17
17A
144J
4F15
SW--2
(P/N 860300)
3F 14,22
(P/N 272131)
(P/N 860301)
Fig. 4 Dual-Channel Air Heater Wiring Diagram
Specifications (contd.)
4204107
HEATER
RTD
4204108
HEATER
RTD
External Air Heater Manual 5
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Fig. 5 Wiring Detail: Cordset with RTD Attached without Wire Nuts
Fig. 6 Wiring Detail: Cordset with RTD Attached with Wire Nuts
Specifications (contd.)
External Air Heater Manual6
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
This section provides instructions for installing the external air heater.
WARNING: Allow only qualified personnel to perform thefollowing tasks. Observe and follow the safety instructions inthis document and all other related documentation.
WARNING: Hot! Risk of burns. Hot melt material may bereleased under pressure. Wear heat-protective clothing, safetygoggles, and heat-protective gloves.
CAUTION: Equipment damage may occur if the unit isconnected to any line voltage other than that stated on the IDplate.
Follow this procedure to install a single-channel air heater for a 2000Series applicator:
1. Use the mounting studs on the gun to secure it over the substrate andto reduce how much the gun moves during application.
NOTE: Mount the gun perpendicular to the substrate and in the samedirection as the travel of the substrate.
2. Complete the adhesive hose-to-gun hydraulic connection at the rearof the gun service block.
3. Use the installation kit to install the inline filter in the air manifold ofthe gun.
4. Secure the spray air hose to the inline filter at the rear side of the gunair manifold.
NOTE: Use only a new hot melt adhesive hose to supply spray air tothe gun. The spray air hose must be completely free of any hot meltmaterial.
5. Mount the single-channel air heater on a 1.3 cm (0.50 in.) diametermounting bar. Position the air heater so that the free end of the sprayair hose reaches the air heater. Then, tighten the lock-down screwsin the retainer clamps.
3. Installation Procedures
Installing a Single-Channel AirHeater for a 2000 Applicator
4204100
4--8 MODULE GUN
SINGLE CHANNELAIR HEATER
2000APPLICATOR
HEATED AIR ADHESIVE
SHOP AIR IN
ELECTRICAL LINE
HEATED HOSE
External Air Heater Manual 7
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
6. Secure the free end of the spray air hose to the single-channel airheater air outlet.
NOTE: Channels on the applicator control the temperature of thespray air hose and of the air heater.
Fig. 7 Single-Channel Air Heater Connection for a 2000 Applicator
Installing a Single-Channel AirHeater for a 2000 Applicator(contd.)
External Air Heater Manual8
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Follow this procedure to install a single-channel air heater for a 2300,3000, or 6000 Series applicator.
1. Use the mounting studs on the gun to secure it over the substrate andto reduce how much the gun moves during application.
NOTE: Mount the gun perpendicular to the substrate and in the samedirection as the travel of the substrate.
2. Complete the adhesive hose-to-gun hydraulic connection at the rearof the gun service block.
3. Use the installation kit to install the inline filter in the air manifold.
4. Secure the spray air hose to the inline filter at the rear or side of thegun air manifold.
NOTE: Use only a new hot melt adhesive hose to supply spray air tothe gun. The spray air hose must be completely free of any hot meltmaterial.
5. Mount the single-channel air heater on a 1.3 cm (0.50 in.) diametermounting bar. Position the air heater so that the free end of the sprayair hose reaches the air heater.
Installing a Single-Channel AirHeater for a 2300, 3000, or 6000Applicator
4204099
4--8 MODULE GUN
SINGLE CHANNELAIR HEATER
2300/6000APPLICATOR
HEATED AIR ADHESIVE
SHOP AIR IN
ELECTRICAL LINE
HEATED HOSE
External Air Heater Manual 9
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
6. Secure the free end of the spray air hose to the single- channel airheater air outlet.
NOTE: Channels on the applicator control the temperature of thespray air hose and of the air heater.
Fig. 8 Single-Channel Air Heater Connection for a 2300, 3000, or 6000 Applicator
Installing a Single-Channel AirHeater for a 2300, 3000, or 6000Applicator (contd.)
External Air Heater Manual10
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Follow this procedure to install a dual-channel air heater.
1. Use the mounting studs on the gun to secure it over the substrate andto reduce how much the gun moves during application.
NOTE: Mount the gun perpendicular to the substrate and in the samedirection as the travel of the substrate.
2. Secure the pair of adhesive hoses hydraulically to the gun serviceblock.
3. Use the installation kit to install the inline filters in the air manifold.
4. Secure the pair of spray air hoses to the inline filters in the gunservice block.
NOTE: Use only new hot melt adhesive hoses to supply spray air tothe gun. The spray air hoses must be completely free of any hot meltmaterial.
5. Position the air heater so that the free end of the spray air hosereaches the air heater without placing undue stress on the hose orconnections.
Installing a Dual-Channel AirHeater for a 2300, 3000, or 6000Applicator
4204101
9--40 MODULE GUN
APPLICATORSHOP AIR IN
ELECTRICAL LINE
ADHESIVE ADHESIVE
HEATEDAIR
HEATEDAIR
DUAL CHANNELAIR HEATER
HEATED HOSE HEATED HOSE
HEATEDHOSE
HEATEDHOSE
(TO AIR HEATER)
External Air Heater Manual 11
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
6. Secure the free ends of the spray air hoses to the dual-channel airheater.
NOTE: Channels on the applicator control the temperature of thespray air hoses.
Fig. 9 Dual-Channel Air Heater Connection for a 2300, 3000, or 6000 Applicator
Installing a Dual-Channel AirHeater for a 2300, 3000, or 6000Applicator (contd.)
External Air Heater Manual12
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
In some cases, it may be necessary to include a stand-alone temperaturecontroller in your system setup. For example, if you wish to control thespray temperature from a single source you can do this with astand-alone, nine-channel temperature controller.
When installing a stand-alone temperature controller, remember thefollowing points:
S Refer to the instructions shipped with the temperature controller forspecific information about your unit.
S Refer to the installation instructions given earlier in this section and inyour gun manual for general setup information.
S Locate the temperature controller so that you do not place unduestress on the electrical cables between the component being heatedand the temperature controller.
S Connect components to the temperature controller electrically afteryou have set up the rest of the system.
S Connect input power to the temperature controller after all otherconnections are complete.
Alternative Installations
External Air Heater Manual 13
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204102
9--20 MODULE GUN
APPLICATORSHOP AIR IN
ELECTRICAL LINE
ADHESIVE
HEATEDAIR
HEATEDAIR
DUAL CHANNELAIR HEATER
HEATEDHOSE
HEATEDHOSE
(TO AIR HEATER)
HEATEDHOSE
HEATEDHOSE
ADHESIVE
9--20 MODULE GUN
ADHESIVE
HEATEDAIR
HEATEDAIR
DUAL CHANNELAIR HEATER
HEATEDHOSEHEATED
HOSE
HEATEDHOSE
HEATEDHOSE
ADHESIVE
STANDALONETEMPERATURECONTROLLER
SHOP AIR IN(TO AIR HEATER)
Fig. 10 Stand-alone Temperature Controller Setup
Alternative Installations (contd.)
External Air Heater Manual14
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
This section provides information for operating the external air heater.
WARNING: Allow only qualified personnel to perform thefollowing tasks. Observe and follow the safety instructions inthis document and all other related documentation.
WARNING: Hot! Risk of burns. Hot melt material may bereleased under pressure. Wear heat-protective clothing, safetygoggles, and heat-protective gloves.
WARNING: Turn off the main circuit breaker (or maindisconnect switch) and disconnect and lock out input power tothe melter. Failure to disconnect external power to the melterpresents a serious shock hazard.
CF 200 guns and hoses receive input electrical power from theapplicator. The guns will not function until the entire system reachesapplication temperature.
Follow this procedure to set up the system to use a single-channelexternal air heater.
1. Install the system according to the applicator manual and Section 3 ofthe gun manual.
2. Turn on the main switch on the external air heater.
3. (Systems with stand-alone temperature controller) Turn on thetemperature controller.
4. Adjust the air heater temperature to 193 _C (380 _F) at the applicator.
5. Set the spray air hose temperature to 193 _C (380 _F) at theapplicator.
6. (Systems with stand-alone temperature controller) Refer to theoperations manual for your controller for information on settingtemperature.
4. Operation Procedures
Setting Up for a Single-ChannelExternal Air Heater
External Air Heater Manual 15
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
7. Set the supply air pressure to the gun solenoid to 40 psi (273 kPa) atthe air heater.
8. Use the heater’s air regulator to adjust the spray air pressure untilyou get the pattern that you wish (1-60 psi, 7-400 kPa).
You may need to adjust the pressure more, depending upon theviscosity of the hot melt material and the gun response requirements.
The system is now ready for use.
CF 200 guns and hoses receive input electrical power from theapplicator. The guns will not function until the entire system reachesapplication temperature.
Follow this procedure to set up the system to use a dual-channel externalair heater.
1. Install the system according to the applicator service manual andSection 3 of the gun manual.
2. Turn on the selector switch at the external air heater.
3. (Systems with stand-alone temperature controller) Turn on thetemperature controller.
4. Push in the temperature selector knob on the air heater and turn theknob until you reach the set point temperature of 193 _C (380 _F).
5. Set the spray air hose temperature to 193 _C (380 _F) at theapplicator.
6. (Systems with stand-alone temperature controller) Refer to theoperations manual for your controller for information on settingtemperature.
7. Set the supply air pressure to the gun solenoid to 40 psi (273 kPa) atthe air heater.
8. Use the air pressure control knob on the air heater front panel toadjust the spray air pressure until you get the pattern that you wish(1-60 psi, 7-414 kPa).
You may need to adjust the pressure more, depending upon theviscosity of the hot melt material and the gun response requirements.
The system is now ready for use.
Setting Up for aSingle-Channel External AirHeater (contd.)
Setting Up for a Dual-ChannelExternal Air Heater
External Air Heater Manual16
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Follow this procedure to shut down an external air heater.
1. Shut down the system according to the applicator manual.
2. Turn off the air heater (and stand-alone temperature controller, ifapplicable).
3. (Dual-Channel Heater Only) Turn off the circuit breaker for the airheater.
4. Reduce supply air pressure and spray air pressure to zero at theregulator on the air heater.
5. Trigger all guns to relieve any trapped hydraulic pressure.
Shutting Down the External AirHeater
External Air Heater Manual 17
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
This section describes problems that can occur during the operation ofthe external air heater, their probable cause, and the corrective action foreach possible cause.
WARNING: Allow only qualified personnel to perform thefollowing tasks. Observe and follow the safety instructions inthis document and all other related documentation.
Table 1 External Air Heater Troubleshooting Guide
Problem Possible Cause Corrective Action
Gun or Single-Channel AirHeater Fails to Heat
Short circuit or low resistance Check resistance between the groundlead and each of the black power leadson the hose. If you find a short circuit,rewire the air heater or replace thedefective component. Restore thesystem to normal operation.
Defective Heater Cartridge WARNING: Disconnect andlock out input electrical powerbefore attempting totroubleshoot the externalheater. The equipmentcontains electrical potentialsthat could be fatal.
Remove the air heater cover and checkcold resistance of the heater cartridgeby reading across heater leads. If youfind abnormal resistance, replace thedefective heater cartridge.
5. Troubleshooting
External Air Heater Manual18
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Problem Possible Cause Corrective Action
Gun or Single-Channel AirHeater Fails to Heat (contd.)
Defective RTD To check the RTD:
WARNING: Disconnect andlock out input electrical powerbefore attempting totroubleshoot the externalheater. The equipmentcontains electrical potentialsthat could be fatal.
CAUTION: Do not heat anycomponent with an openflame or torch. Damage mayresult.
1. Remove the air heater cover.2. Disconnect RTD leads from cordset
leads.leads.3. Connect an ohmmeter set to the
lowest resistance scale.4. Heat the air heater RTD with aneat t e a eate t a
electric flameless heat gun. Note theposition of the ohmmeter indicator asthe service block/RTD is heated.
A resistance reading outside the normalA resistance reading outside the normalrange indicates a defective RTD.Replace the defective RTD and restorethe system to normal operation.
Gun or Single-Channel AirHeater Overheats
Improper setting of temperatureselector
Reset as necessary. See applicatormanual.
Defective RTD Refer to the previous procedure forchecking the RTD.
External Air Heater Manual 19
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Problem Possible Cause Corrective Action
Actual Spray Air TemperatureBelow 193 _C (380 _F)Setpoint
Improper setting of air heatertemperature
Reset temperature as necessary. Seeapplicator manual.
Faulty over-temperature circuit To check air channel over-temperaturecircuit:
WARNING: This equipmentcontains energized potentialsthat could be fatal. Disconnectand lock out input electricalpower before you proceed.
1. Turn circuit breaker off anddisconnect power to the unit.
2. Remove the four pan-head screwsthat secure the access panel to theleft side panel, then remove theaccess panel.
3. Check the continuity across the OTCfuse elements (wires 11-4D and20-4G).
If there is no continuity across one orboth circuits, replace faulty circuits.
Faulty mercury relay To check the mercury relay:
WARNING: This equipmentcontains energized potentialsthat could be fatal. Disconnectand lock out input electricalpower before you proceed.
NOTE: Ensure that you have installedthe air heater in a horizontal position;otherwise, the mercury relay contactswill remain closed.1. Turn off the circuit breaker and
disconnect power to the unit.2. Remove the five pan-head screws
that secure the cover to the unit, thenlift the cover from the unit.
3. Reconnect power to the unit.4. Adjust the setpoint temperature to
approximately 10 _C (50 _F).5. Check for 240 V across the relay
coils.If 240 volts are not present, check thewiring back to the temperaturecontroller.If the wiring is okay, replace the relay.
External Air Heater Manual20
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Problem Corrective ActionPossible Cause
Actual Spray Air TemperatureBelow 193 _C (380 _F)Setpoint (cont.)
Faulty heater cartridge To check the heater cartridge:
WARNING: This equipmentcontains energized potentialsthat could be fatal. Disconnectand lock out input electricalpower before you proceed.
1. Switch the circuit breaker off anddisconnect electrical power.
2. Pry circular plugs from the air heaterside panel.
3. Check heater cartridge resistance.If the heater cartridge resistance is notwithin the specifications, replace theheater cartridge.
Faulty RTD To check the RTD:
WARNING: This equipmentcontains energized potentialsthat could be fatal. Disconnectand lock out input electricalpower before you proceed.
1. Switch the circuit breaker off anddisconnect electrical power.
2. Pry circular plugs from the air heaterside panel.
3. Check RTD resistance.If the RTD resistance is not within thespecifications, the digital display willread EEE if the RTD fails open.Replace the RTD.For the proper RTD specifications, seeFigure 11.
External Air Heater Manual 21
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4106083
Fig. 11 RTD Resistance Versus Temperature
External Air Heater Manual22
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
This page intentionally left blank.
External Air Heater Manual 23
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
This section contains illustrated parts lists for all the various assembliesfor the external air heater.
The parts list contains information about the parts used in the external airheater documented by this publication. The following information isincluded in each parts list:
S The Item column indicates the number corresponding to theillustrated part in the drawing. A dash in this column means that theitem is included in the list for reference only and is not part of theassembly drawing.
S The Part column indicates the Nordson part number for the item. Adash in this column means that the item is not available for sale byNordson or that it is part of a subassembly that is available for sale.
S The Description column indicates the part’s name. The dimensionsand physical properties may also be included in the part description.
S The Quantity column indicates the total number of that part used inthe assembly. If the item is listed for reference only, Ref appears inthis column.
S The Note column contains letters that refer to notes at the bottom ofthe parts list. Notes provide kit part numbers and other keyinformation that you need to order parts.
6. Parts
Using the Parts List
External Air Heater Manual24
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
This page intentionally left blank.
External Air Heater Manual 25
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
- 860 428 Air Heater, Model 2000 Applicator Ref
1 270 604 S Nameplate, AD28 1
2 272 384 S Kit, Retainer, Gun 2
3 272 400 S Insulator, Mount, H200 2
4 273 905 S Cordset Assembly, 5 Wire 1
5 600 082 S Nameplate, Nordson Oval 1
6 815 154 S Spline, Heat Exchanger 2
7 860 302 S Feet, Support 4
8 860 421 S Body, Heat Exchanger 1
9 860 422 S Insulator, Air Heater 2
10 860 424 S Cover, Electrical, Painted 1
11 860 425 S Insulation-Input End 1
12 860 426 S Insulation-Output End 1
13 860 427 S Insulation-Lower 1
14 860 429 S Insulation-Upper 1
15 860 431 S Enclosure, Air Heater, Painted 1
16 860 433 S Base, Air Heater, Painted 1
17 860 434 S Nipple, Pipe Brass 1/4--18 x 2.5 1
18 860 446 S Insulation-Side 2
19 860 530 S Valve, Solenoid, 115 VAC/24 VDC 1
- 860 579 S Test Spec, 2000 Series, Air Heater Ref
21 860 651 S Heater, 120 V 300 W 2
22 900 344 S Lubricant, Never Seez, 8oz Can -
23 901 251 S Gauge, Air, 1/8 Npt, 60 psi/400 kPa 1
24 901 442 S Regulator, 1/4 Nptf, 1-60 psi/7-400 kPa 1
- 933 056 S R Connector, Wire, Porcelain 5
- 939 523 S Sensor, Temp, Gun 1
Continued on next page
7. Illustrated Parts List
Model 2000 Single-Channel AirHeater Parts List
External Air Heater Manual26
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
27 972 624 S Connector, Female, 37, 9/16--18 x 1/4, Brass 1
28 973 026 S Nipple, Extra Heavy, 1/4 x .87 1
29 973 032 S Nipple, Steel, Schedule 40,1/4, 2.50 1
30 973 391 S Bushing, Red, 3/4 x 3/8, Stl, Zinc 2
31 973 403 S Plug, Pipe, Socket, Flush, 1/16, Zinc 2
32 973 411 S Plug, Pipe, Socket, Flush, 1/4, Zinc 1
33 981 000 S Screw, Fillister-head, 5--40 x .250, Sl, Zinc 1
34 981 064 S Screw, Pan, 8--32 x 0.375, Steel, Zinc 8
35 981 315 S Screw, Hex, 5/16--18 x 1.000, Cap, Zinc 2
36 981 316 S Screw, Hex, 5/16--18 x 1.500, Cap, Zinc 2
Model 2000 Single-Channel AirHeater Parts List (contd.)
External Air Heater Manual 27
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204109
36 35 2
3
1
31
22
21 30 9 31 13
22 22 22
16 34 711 32
22
17 10 12 14 33 8 5156 29
23
24
27
22
18 22
19
22
28
22
4
OUTLET
Fig. 12 2000 Single-Channel Air Heater
External Air Heater Manual28
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
This page intentionally left blank.
External Air Heater Manual 29
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
- 860 436 Single-Channel Air Heater 2300/3000/6000Applicators
Ref
1 270 604 S Nameplate, AD 28 1
2 272 384 S Kit, Retainer, Gun 2
3 272 400 S Insulator, Mount, H200 2
- 274 650 S Gasket, Connector, Cordset 1
- 274 651 S Gasket, Connector 1
6 274 652 S Connector, Socket, 12 Pin 1
7 600 082 S Nameplate, Nordson Oval 1
8 815 154 S Spline, Heat Exchanger 2
9 860 302 S Feet, Support 4
10 860 421 S Body, Heat Exchanger 1
11 860 422 S Insulator, Air Heater 2
12 860 425 S Insulation-Input End 1
13 860 426 S Insulation-Output End 1
14 860 427 S Insulation-Lower 1
15 860 429 S Insulation-Upper 1
16 860 431 S Enclosure, Air Heater, Painted 1
17 860 433 S Base, Air Heater, Painted 1
18 860 446 S Insulation-Side 2
19 860 529 S Cover, Electrical, Air Heater, Ptd 1
20 860 530 S Valve, Solenoid, 115 VAC/24 VDC 1
21 860 535 S Cordset Assy, Air Heater, 6000 1
- 860 580 S Test Spec, 2300/6000 Air Heater Ref
23 860 651 S Heater, 120 V 300 W 2
24 900 344 S Lubricant, Never Seez, 8 oz Can -
25 901 251 S Gauge, Air, 1/8 Npt, 60 psi/400 kpa 1
26 901 442 S Regulator, 1/4 Nptf, 1-60 psi/7-40 kPa 1
- 933 056 S Connector, Wire, Porcelain 4
28 972 624 S Connector, Female, 37, 9/16--18 x 1/4, Brass 1
29 973 026 S Nipple, Extra Heavy, 1/4 x 0.87, St 1
Continued on next page
Models 2300, 3000, or 6000Single-Channel Air Heater PartsList
External Air Heater Manual30
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
30 973 032 S Nipple, Steel, Schedule 40, 1/4, 2.50 1
31 973036 S Nipple, Brass, Schedule 40, 1/4, 3.00 1
32 973 391 S Bushing, Red, 3/4 x 3/8, Steel, Zinc 2
33 973 403 S Plug, Pipe, Skt, Flush, 1/16, Zinc 2
34 973 411 S Plug, Pipe, Skt, Flush, 1/4, Zinc 1
35 981 000 S Screw, Fillister-head, 5--40 x .250, Sl, Zinc 1
36 981 064 S Screw, Pan, 8--32 x 0.375, Sl, Zinc 8
37 981 315 S Screw, Hex, 5/16--18 x 1.000, Cap, Zinc 2
38 981 316 S Screw, Hex, 5/16--18 x 1.500, Cap, Zinc 2
39 981 771 S Screw, Socket, 10--32 x 1.375, Zinc 2
40 983 010 S Washer, Flat, E, 0.188 x 0.375 x 0.040, Zinc 8
41 983 051 S Washer, Flat, E, 0.344 x 0.688 x 0.065, Zinc 4
42 983 120 S Washer, Split Lock, E, #10, Stl, Ni 2
43 983 509 S Washer, Lock, E, Ext, 1/2, Stl, Zinc 1
44 984 140 S Nut, Hex, Reg, 5/16--18, Stl, Zinc 4
45 984 216 S Nut, Mounting, Panel 1
46 985 111 S Rivet, Blind, 3/32 x 0.125, Black, Alum 4
47 985 113 S Rivet, Pop, 1/8 x 0.312, Black, Alum 4
48 986 316 S Retaining Ring, Ext, 12, Pshn, Cs 2
Models 2300, 3000, or 6000Single-Channel Air HeaterParts List (contd.)
External Air Heater Manual 31
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204114
OUTLET
1
15
6
24
34
45
43
21
31
28
24
19 35 10 8 16
18
24
38 372
41 3 40
30
24
42
26
24
20
24
25
24
2933 23 32
11
33 14 7 123617
24 24
41
48 40
46
9 44
13
39
Fig. 13 2300, 3000, or 6000 Single-Channel Air Heater
External Air Heater Manual32
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
- 860 352 Dual-Channel Air Heater -
1 860 326 S Weldment, Air Heater, Painted 1
2 860 327 S Barrier, Heat, Painted 1
3 981 161 S Screw, Pan, 10-32 x .375 18
4 983 120 S Washer, Lock, E, Spt, #10 13
5 860 314 S Channel, U-shaped x 10.00 long 2
6 981 264 S Screw, Flat, 1/4--20 x 0.750 4
7 984 130 S Nut, Hex, Heavy, 1/4--20 4
8 983 140 S Washer, Split Lock, E, Spt, 1/4 4
9 860 313 S Nut, Clamping 2
10 860 318 S Rod, Threaded, 1/2--13 x 5.5 lg 2
11 860 490 S Clamp, Holddown, Air manifold 2
12 984 170 S Nut, Hex, Reg, 1/2--13, Stl, Zn 2
13 983 180 S Washer, Lock, E, Spt, 1/2, Stl, Ni 2
14 861 048 S Heater, Cartridge, 1700 W, 240 V 2
15 939 305 S Sensor, Temp., Rtd, 1/4 diameter 2
16 860 330 S Reservoir, Air heating 2
17 933 056 S Connector, Wire, Porcelain 12
18 937 281 S Thermostat, Close-on-rise, 278 _C (500 _F) 2
19 981 000 S Screw, Fillister-head, 5--40 x 0.250, Sl, Zn 6
20 273 730 S Insulator, Thermostat, Electric 2
21 860 312 S Support, Porcelain Saddle 4
22 860 308 S Insulation, End, Left 1
23 860 500 S Insulation, End, Right 1
24 860 309 S Insulation, Side 2
25 860 310 S Insulation, Lower 1
26 860 311 S Insulation, Upper 1
27 860 486 S Fitting, Bulkhead, 3/8 O.D. Tube 2
28 275 062 S Nameplate, Hose, No. 1 1
29 275 063 S Nameplate, Hose, No. 2 1
Continued on next page
Models 2300, 3000, or 6000Dual-Channel Air Heater PartsList
External Air Heater Manual 33
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
30 985 113 4
31 861 049 2
32 860 487 2
33 900 236 -
34 860 615 2
35 973 117 2
36 973 032 1
37 860 614 2
38 860 617 8
39 860 302 4
40 984 140 4
41 803 789 4
42 860 341 1
43 860 945 2
44 860 613 2
45 860 612 6
46 861 047 2
47 860 611 2
48 860 610 2
49 901 132 2
50 860 618 2
- 860 322 1
52 860 300 2
53 939 177 1
54 973 402 2
55 933 314 1
56 860 342 1
57 984 509 2
58 933 128 8
59 860 307
S Rivet, Pop, 1/8 x 0.312, Blk, Alum
S Tube, Ss, 0.375 o.d. x 2.56 long
S Fitting, Elbow, 9/16--18 straight head
S Sealant, Paste
S Adapter, 9/16--18 x 1/4 Nptf
S Nipple, Steel, Schedule 40, 1/4, 1.50
S Nipple, Steel, Schedule 40, 1/4, 2.50
S Fitting, Female Elbow, 1/4 Npt x 3/8 O.D.
S Tubing, Copper, 50 ft, 0.375 O.D. ft
S Feet, Support
S Nut, Hex, Reg, 5/16--18, Stl, Zn
S Control, Temp, Pump, Deg. F
S Plate, Front, Air Heater
S Gauge, Panel Mtg., 60 psi/400 kPa
S Fitting, Female, Conn., 1/8 Npt x 3/8 O.D.
S Fitting, Compression, Elbow, 1/4 Npt x 3/8
S Regulator, Air, 0-60 psig, 1/4 Npt
S Fitting, Compression, Elbow, 1/8 Npt x 3/8
S Fitting, Compression, Male, 1/4 Npt x 3/8
S Valve, Solenoid, 2-way, 218 V, 1/4 Npt
S Bracket, Solenoid, Painted
S Cover, Air heater, Painted
S Switch, Rockers P.s.t.
S Lamp, Indicator, Rectangle, Red, 250 V
S Plug, Pipe, Socket, Flush, 1/8, Zn
S Block, Terminal, 10-station
S Wire Group, Air Heater
S Nut, Round
S Jumper, Terminal, Block, Low Pf
S Relay, Dpst Mercury, 240 V 2
Continued on next page
Models 2300, 3000, or 6000Dual-Channel Air Heater PartsList (contd.)
External Air Heater Manual34
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
60 981 060 S Screw, Pan, 8-32 x 0.500 4
61 984 111 S Nut, Hex, Mach, #8-32 4
62 983 111 S Washer, Lock, E, Spt, #8, Stl, Zn 4
63 806 058 S Adapter, Disconnect, 0.250 Tab 4
64 270 604 S Nameplate, Ad28 1
65 933 005 S Connector, Cord 1
66 939 475 S Locknut, Conduit, 1/2 1
67 973 968 S Adapter, Bulkhead, 1/4 Npt 1
68 860 616 S Fitting, Tee, Comp., 1/4 Npt x 3/8 O.D. 1
- 272 131 S Stud, Ground, w/ accessories 1
70 271 838 S Heat Limiter 2
71 271 837 S Block, Terminal, 4-station, One Row 2
72 981 035 S Screw, Pan, 6-32 x 0.625 4
73 984 101 S Nut, Hex, Mach, #6-32 4
74 983 102 S Washer, Lock, E, Spt, #6 4
75 981 511 S Screw, Pan, 6-32 x 0.500 4
76 860 320 S Cover Plate, Access, Painted 1
77 981 039 S Screw, Pan, 6--32 x 0.312 4
78 860 301 S Circuit Breaker, 20 Amp 1
79 860 645 S Plug, Hole, 1.750 Diameter 2
- 860 344 S Wiring Diagram, Air Heater 1
- 860 343 S Schematic, Air Heater -
82 981 079 S Screw, Pan, 8-32 x 0.625 2
83 860 648 S Cover, Terminal Block, 10-station 1
84 981 083 S Screw, Pan, 8--32 x 0.250 long 2
85 242 867 S Tag, Warning 1
- 271 880 S Tag, Warning, Disconnect Power 1
87 985 111 S Rivet, Blind, 3/32 x 0.125 6
88 245 575 S Spacer, Cartridge 2
Models 2300, 3000, or 6000Dual-Channel Air Heater PartsList (contd.)
External Air Heater Manual 35
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204110
59
52
60
61
62
63
33
34
36
37
2
3
4
5
6
7
8
9
10
11
12
13
21
22
23
24
25
26
14
15
16
17
18
19
20
88
3
4
33
48
49
50
68
6933
35
48
67
1
79
32
27
28
33
30
38
6430
6665
55565758
82838485
77
78
53 41 3333
45
46
47
54
43
44
75
71
72
73
747670
86 51 3
42
39
87
40 63
3
4
33 50
49
45
31
29 30
Fig. 14 Dual-Channel Air Heater (2300, 3000, or 6000 Applicator)
External Air Heater Manual36
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
– 273 905 Cordset Assembly, 5 Wire Ref
1 – S Wire Group, 5 Wire 1
2 272 749 S Plug, Connector 1
3 272 748 S Hood, Top Entry 1
4 273 938 S Eyelet, w/ dimple 1
5 273 901 S Cordset, Wire, Gun 1
6 986 317 S Retaining Ring, Ext, 40, Basic 1
Model 2000 Applicator 5-WireCordset
External Air Heater Manual 37
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204111
������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
1
2 3
5 6
4
6
1
3
2
3
4
5
6
7
931195
931121
931121
931194
931194
PINS
RTD WIRES
Fig. 15 2000 Applicator 5-Wire Cordset
External Air Heater Manual38
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
- 274 685 Cordset Assembly, 2300, 3000 or 6000 Ref
1 274 731 S Sensor, Temperature, Gun 1
2 933 006 S Terminal, Ringtong, Non insulated 1
3 981 759 S Screw, Pan, 4--40 x 0.312 1
4 – S Connector, Pin Holder 1
5 981 754 S Screw, Flat, Self-Tapping, 4--40 x 0.312 2
6 274 619 S Shell, Hose 1
7 – S Wire Group, Model 2300 1
8 981 001 S Screw, Pan, 4--40 x 0.187 1
9 983 101 S Washer, Lock, E, Int, #4 1
10 – S Conduit, Electrical Cordset 1
11 945 041 S O Ring, 0.394 x 0.039 1
12 – S Connector, Pin, 20--24 awg 2
13 940 202 S O ring, 0.752 x 0.063 1
Models 2300, 3000, or 6000Applicator Cordset
External Air Heater Manual 39
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204112
1
2
3
5
4
1
2
RTD
RTD
GND
2
11
3 4
65 13
1 7
10
9
8
12
5
4
2
3
1
Fig. 16 2300, 3000, or 6000 Applicator Cordset
External Air Heater Manual40
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
– 860 535 Cordset Assembly, Air Heater, 3000, 6000 Ref
1 939 218 S Connector, Pin, 16--18 awg, Gold 6
2 933 056 S Connector, Wire, Porcelain 1
3 – S Wire Group, Air Heater 1
4 860 533 S Conduit, Electrical Cordset, 1
5 – S Connector, Split Strain Relief 1
6 981 754 S Screw, Flat, Self Tap, 4--40 x 0.312 2
7 100 307 S Shell, Convertible Connector 1
8 – S Pin, Connector, Holder 1
9 – S Connector, Pin, 20--24 awg, Gold 2
10 940 202 S O ring, 0.752 x 0.063 1
Model 3000 or 6000 Air HeaterCordset
External Air Heater Manual 41
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
4204113
1
2
3
4
5
6
8
9
10
11
12
1
2
3
4
5A
6
8
3 4 5 6 7 10 8
2
1
9
RTD
RTD DETAIL
WIRE NUMBERS35
A
A
VIEW A--A
WIRE NUMBERSGND4681
3,5
25A
RTD
GND
Fig. 17 6000 Air Heater Cordset
External Air Heater Manual42
E 1995 Nordson CorporationAll rights reserved
42--CF200--IS--06 (formerly 46-248)Issued 4/95
P/N 107 026A
Item Part Description Quantity Note
- - Air Heaters -
1 274 796 S Hose, Hot Melt, 2300 or 6000 16 ft 230 VAC -
2 901 513 S Filter/Regulator 1/4 Npt -
3 901 254 S Air Gauge, 1/8 Npt, psi-kPa-kg/cm -
- - S Temperature Control -
5 860 662 S Adapter Cable (a hose spitter that converts afive-channel temperature controller hose and gunchannel to a two-gun channel)
-
6 860 663 S Adapter Cable (a gun spitter that converts afive-channel temperature controller hose and gunchannel to a two-gun channel)
-
- - S Miscellaneous -
8 809 549 S Extension Cord, Electrical Hose, 12 ft -
9 274 287 S Inline Filter, Adhesive Hose, O-ring seal, 90degree, 0.011 in. (0.28 mm), 200 mesh
-
10 273 413 S Inline Filter, Air Hose, 1/4 Npt, 90 degree, 0.003 in.(0.08 mm), 200 mesh
-
11 901 081 S Solenoid Valve, 120 VAC/24 DC -
Supplementary Equipment