explosion-protected motors · explosion-protected design complying with equipment group ii,...

4
Explosion-protected motors Type of protection flameproof enclosure “d/de” Efficiency classes IE2 and IE3 www.vem-group.com

Upload: others

Post on 16-Oct-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Explosion-protected motors · Explosion-protected design complying with equipment group II, category 2 Ex d(e) EN 60079-0 General requirements EN 60079-1 flameproof enclosure “d”

Explosion-protected motors

Type of protection flameproof

enclosure “d/de”

Efficiency classes IE2 and IE3

www.vem-group.comwww.vem-group.com

Page 2: Explosion-protected motors · Explosion-protected design complying with equipment group II, category 2 Ex d(e) EN 60079-0 General requirements EN 60079-1 flameproof enclosure “d”

Safe drives in case of explosion hazards Situations in which explosive gas or vapour/air mixtures can be formed, or where combustible dusts can arise, call for special electric drives. VEM is able to supply drives to suit your particular needs, because› highly qualified specialists are at hand to advise our

customers› VEM has many decades of experience in high-

quality explosion-protected drives› production in our factories is governed by a quality

management system certified by IBExU Freiberg› machines are available for use in hazardous areas in

zones 1 and 2, equipment group II, categories 2 and 3› VEM drives of this type are already operating relia-

bly at renowned European and global chemical and power enterprises.

Quality tested and certifiedThe motors of the VEM type series are tested and cer-tified by › Physikalisch-Technische Bundesanstalt Braunschweig

(Notified Body no. 0102), and comply with the directive 94/9/EC – ATEX 95. The test certificates are recognised by all member states of the European Union, and are additionally accepted by those CENELEC members which do not belong to the EU. In the case of special versions influencing explosion protection (pole-changing motors, other fre-quencies, outputs or coolant temperatures, converter operation, etc.), supplementary or renewed approval is required. Production quality assurance measures are certified by IBExU Freiberg and are monitored in accordance with Art. 10 (1) of the directive 94/9/EC.

Exp

losi

on-p

rote

cted

mot

ors

flam

epro

of e

nclo

sure

“d/

de”

Explosion-protected motorsType of protection flameproof enclosure “d/de” Efficiency classes IE2 and IE3Drives for the chemical and petrochemical industries and for offshore applications

Page 3: Explosion-protected motors · Explosion-protected design complying with equipment group II, category 2 Ex d(e) EN 60079-0 General requirements EN 60079-1 flameproof enclosure “d”

Exp

losi

on-p

rote

cted

mot

ors

flam

epro

of e

nclo

sure

“d/

de”

Size 63 to 450Power range 0.06 – 630 kWVoltage to 1100 V, size 355 – 450: 11000 VEfficiency class IE2 and IE3 acc. to IEC/EN 60034-30-1 in the power range 0.75 …375 kW, 2-, 4- and 6-poleType of protection IP 55, IP 56, IP 65 acc. to IEC/EN 60034-5Type of construction IM B3, IM B35, IM B5, IM B14, IM B34 and derived types of construction acc. to IEC/EN 60034-7Explosion-protected design complying with equipment group II, category 2 Ex d(e) EN 60079-0 General requirements EN 60079-1 flameproof enclosure “d”Ambient temperature -55 °C up to +60 °CTemperature class T3 to T6Type of cooling IC 411 acc. to DIN IEC/EN 60034-6

Mounting dimensions and performances acc. to DIN 42673 sheet 3 and DIN 42677 sheet 3

Series K82R, B82R (-Y2, -Y3) (Y2 corresponds with IE2 design, Y3 corresponds with IE3 design)

Overview of approvals:

Design series and sizes Ex II 2G Ex d(e) IIC T3 – T6 Ex II 2G Ex d(e) IIB+H2 T3 – T6K82, 63 – 71 (-Y2. -Y3) PTB09ATEX1017 X PTB09ATEX1032 XK82, 80 – 160 (-Y2. -Y3) PTB09ATEX1018 X PTB09ATEX1033 XK82, 180 (-Y2. -Y3) PTB09ATEX1019 X PTB09ATEX1034 XK82, 200 (-Y2. -Y3) PTB09ATEX1020 X PTB09ATEX1035 XK82, 225 – 315 (-Y2. -Y3) PTB09ATEX1018 X PTB09ATEX1033 XK82, 355 (-Y2. -Y3) PTB09ATEX1021 X PTB09ATEX1036 XK82, 400 PTB09ATEX1022 X PTB09ATEX1037 XK82, 450 PTB09ATEX1023 X PTB09ATEX1038 XB82, 80 – 132 PTB09ATEX1039 X

Example of identification mark:Ex d IIC T4 Gb

Please refer to our catalogues for technical details. The catalogues are available in printed or in digital version on DVD. They are also available in the internet.

Explosion-protected motors with protection rating “d/de” (flameproof) play out their strengths as special electric drives for environments subject to explosive gas-air mixtures.

Page 4: Explosion-protected motors · Explosion-protected design complying with equipment group II, category 2 Ex d(e) EN 60079-0 General requirements EN 60079-1 flameproof enclosure “d”

www.vem-group.com

© 2015 KOMMUNIKATION SCHNELL GmbH

VEM/05-022 E/0315 Printed in Germany. Subject to change.

For detailed information please visit our website.

VEM Holding GmbH

Pirnaer Landstraße 176 D-01257 Dresden

Phone: +49 351 208-0 Fax: +49 351 208-1028

VEM Sales

Low voltage

Phone: +49 3943 68-0 E-Mail: [email protected]

High voltage

Phone: +49 351 208-0 E-Mail: [email protected]

Drive systems

Phone: +49 30 9861-2104 E-Mail: [email protected]