explosion proof/ dust ignition proof vacuum cleaner · pdf filedust ignition proof vacuum...
TRANSCRIPT
Explosion Proof/Dust Ignition Proof
Vacuum Cleaner Systems
Safety has no Compromise
Electric & Pneumatic Systemsfor wet & dry recovery
About Tiger VacWith fourty years of experience, Tiger-Vac has successfully established itself in the international market as a manufacturer of high quality Explosion Proof, Industrial and Cleanroom Vacuum Cleaner Systems.
Tiger-Vac has accomplished this by listening to its clients and responding to their needs. Our many diverse clientele include the military, pharmaceutical industries, food processing plants as well as many other industries that have a need for specialized vacuum cleaner systems. Many of these industries require HEPA vacuums as well as vacuums for controlled or hazardous environments.
Our specialty lies in our ability to tailor our vacuum cleaners to meet your specialized needs. Our team of professionals are eager to help you, and as we are manufacturers, we are able to build a vacuum cleaner specifically to meet your needs.
Certified ISO 9001:2000 we strive to assure quality, not only in our products, but also in the materials that we receive from our suppliers. We also take pride in our customer service and sales department staff who are always on hand to serve you.
A Word From The PresidentTiger-Vac sold its first vacuum cleaner in 1969. Having been in business for over 40 years, we have come to know our industry very well. Our customers demand a commitment to manufacturing and delivering quality vacuum cleaners that suit their various needs. Being ISO 9001:2000, CSA, ATEX and IECEx certified we have not only met these demands but exceeded them. We continuously strive to improve upon our existing products as well as design new systems to serve ever changing industries.
Rocco Mariani CEO & Founder
g g
cco Mariani & Founder
Classes & GroupsClass I locations are areas in which flammable gases / vapors may be present in the air in quantities sufficient to produce explosive or ignitable mixtures:
Group A:• acetylene
Group B:• hydrogen or gases/vapors of equivalent
Group C: • ethyl ether vapors, ethylene or cyclopropane
Group D:• gasoline, hexane, naptha, benzine, butane, benzol, lacquer solvent vapors, natural gas
Class II deals specifically with combustible dusts. The dust may be suspended in the air, in a cloud or in a layer on electrical equipment. The ignition temperature of a dust layer is usually lower than for a dust cloud.
Group E:• metal dusts (aluminum, magnesium and their alloys) and other combustible dusts whose particle size, abrasiveness and conductivity present similar hazard
Group F:• carbonaceous dusts (carbon black, charcoal, coal or coke) that have more than 8% total entrapped volatiles or dusts sensitized by other materials so they present an explosion hazard
Group G:• combustible dusts not included in groups E & F, including Flour, Grain, Wood, Plastic & Chemicals
When it’s time to “pick-up” and choose your explosion proof vacuum cleaner system make sure that it has been certified by an independent testing laboratory (NRTL). Explosion proof vacuum cleaners must comply with NFPA Class I Group D and Class II Groups E (metal dust), F & G in North America and ATEX Category 2 Zone 1 (gas) & Zone 21(dust) in Europe and also other countries where IECEx is recognized. Choosing a certified explosion proof vacuum cleaner is the best choice to protect yourself and your employees.
Do you work in a hazardous location?
Hazardous locations are areas where fire or explosion hazards may exist due to the presence of flammable gases/vapors, flammable liquids, combustible dust or ignitable fibers. The type of hazard is defined as an “explosion hazard” in Class I and II locations, and a “fire hazard” in Class III locations.
Materials do not have to be in the gaseous state for an explosion. Combustible dusts and atomized liquids are other examples.
TAKE OUR ADVICE SAFETY HAS
NO COMPROMISE
EXPLOSION PROOF LINE OF VACUUMESElectrically OperatedEXP1-10 to 55 RE HEPA Series Page 4
EXP1-55 DMB RE HEPA & EXP1-35L RE HEPA Series Page 5
EXP1-20L (DT) RE HEPA & EXP1-40L (4W) RE HEPA Page 6
Electrically Operated Continuous DutyCD-1500 EX CR, CD-1501 EX CR & CD-2600 EX CR Series Page 7
CD-3 EX HEPA Series, CD-4/5/7 EX Series & Page 8CD-IT EX (CFE) HY-C
European ModelsEUR-HLMT-20L/35L/60L/100L EX DT (MFS) & Page 9EUR/HLMT-35L EX DT (MRP)
EUR EX Series Page 10
Pneumatically OpperatedSSAT-2L, SSAT-6L & SS-IT EX (HY-C) HEPA Page 11
SS-10/15/25/55 RE HEPA Series & SS-55 DMB RE HEPA Page 12
SS-35L RE HEPA Series & SS-63L RE HEPA Page 13
SS-20L (DT) RE HEPA & SS-40L (4W) RE HEPA Page 14
Recovery Units & Special Function UnitsIT-25/55 & INT-55 Page 15
AC-25 (4W) EX & Primary Cyclonic Transfer Adapter Page 16
Filter Cleaning SolutionsFilter Cleaning Option descriptions Page 17
Electrically Operated Series
4
EXP1-10 to 55 RE HEPA SeriesWet and dry recoveryLegally certified explosion proof/dust • ignition proof vacuum cleaner
Single phase motor•
All stainless steel AISI 304 construction • (except tilt cart)
HEPA standard / ULPA Filtration optional•
Middle Ring with Activated Carbon • (MRAC) available
Based either on a 4 wheel dolly or on • a 4 wheel tilting cart to allow for easy emptying of recovered materials
Models available for pharmaceutical • applications
44
y Operated Series
EXP1-15 (TC) RE
EXP1-55 (TC) RE
EXP1-10 (4W) RE
EXP1-10 EXP1-15 EXP1-25 EXP1-55
Operation 120/230 V50/60 Hz
120/230 V50/60 Hz
120/230 V50/60 Hz
120/230 V50/60 Hz
Recovery tank capacity
Wet7.5 gal
28l12.5 gal
47l17 gal64l
45 gal170l
Dry6 gal22l
10 gal38l
15 gal57l
40 gal151l
Tools & Accessories Included Included Included Included
HEPA Filter H14 Included Included Included Included
Number of Filters 3 3 3 3
MRAC Available Available - -
Polyliner & Clip Optional Optional Optional Optional
Electrically Operated Series
5
EXP1-55 DMB RE HEPAWet and dry recovery Legally certified explosion proof/dust ignition • proof vacuum cleaner
Single phase motor•
All stainless steel AISI 304 construction• (except cart)
HEPA standard / ULPA filtration optional•
Tilting cart equiped with dead man Brake • (DMB)
Equiped with grounding reel with 50’ stainless • steel cable
Model available for fuel recovery•
EXP1-35L RE HEPA SeriesDry recovery Legally certified explosion proof/dust ignition • proof vacuum cleaner
Single phase motor•
All stainless steel AISI 304 construction• (except cart)
HEPA standard / ULPA filtration optional•
Detachable recovery tank (DT)•
Available with manual filter shaker (MFS) or • manual reverse purge (MRP)
Electrically Operated Series
•
•
•
•
•
•
•
•
•
••
5 EXP1-35L RE MRP
EXP1-55 (DMB) RE
EXP1-55 DMB EXP1-35L MRP EXP1-35L MFS
Operation 120/230 V50/60 Hz
120/230 V50/60 Hz
120/230 V50/60 Hz
Recovery tank capacity
Wet45 gal170l - -
Dry40 gal151l
8.75 gal35l
8.75 gal35l
Tools & Accessories Included Included Included
HEPA Filter H14 Included Included Included
Number of Filters 3 1 2
Polyliner & Clip Optional Included Included
Electrically Operated Series
6
EXP1-20L (DT) RE HEPADry recovery Legally certified explosion proof/dust ignition • proof vacuum cleaner
Single phase motor•
All stainless steel AISI 304 construction • (except cart)
HEPA standard / ULPA filtration Optional•
Manual filter shaker (MFS)•
Detachable recovery tank (DT)•
EXP1-40L (4W) RE HEPADry recoveryLegally certified explosion proof/dust ignition • proof vacuum cleaner
Single phase motor•
All stainless steel AISI 304 construction•
HEPA standard / ULPA filtration Optional•
Based on a 4 wheel dolly•
Model available for pharmaceutical applications•
on
on
66666
EXP1-20 (DT) RE
EXP1-40L (4W) RE
EXP1-20L EXP1-40L
Operation 120/230 V50/60 Hz
120/230 V50/60 Hz
Recovery tank capacity
6.25 gal25l
13.5 gal40l
Tools & Accessories Included Included
HEPA Filter H14 Included Included
Number of Filters 2 2
Polyliner & Clip Included Included
Electrically Operated Continuous Duty
7
CD-1500 & CD-1501 EX CRDry recoveryLegally certified explosion proof/dust ignition • proof vacuum cleaner
Continuous duty single and three phase motor•
Components available in all Stainless Steel or • white powder coated
Optional HEPA or ULPA filtration available•
Cleanroom compatible•
Models available for pharmaceutical applications•
CD-2600 EX CR SeriesDry recoveryLegally certified explosion proof/dust ignition • proof vacuum cleaner
Continuous duty single and three phase motor•
Components available in all Stainless Steel or • white powder coated
Optional HEPA or ULPA filtration available•
Cleanroom compatible•
Available with Manual Filter Shaker (MFS), • Manual Reverse Purge (MRP) or Automatic Reverse Purge (ARP)
Model available for pharmaceutical applications•
y p
•
•
•
•
•
•
•
•
•
7
CD-1500 EX CR
CD-1501 EX CR
CD-2600 EX CR
CD-1500 CD-1501 CD-2600
Operation60Hz 120, 230,
460 & 575V120, 230,
460 & 575V120, 230,
460 & 575V
50Hz 400V 400V 400V
Recovery tank capacity 5 gal / 19l 7.5 gal / 28l 9.5 gal / 38l
Tools & Accessories Optional Optional Optional
HEPA Filter H14 Optional Optional Optional
Number of Filters 1 1 1
Polyliner & Clip Included - -
Electrically Operated Continuous Duty
8
CD-3 EX HEPA SeriesWet and dry recoveryLegally certified explosion proof/dust ignition proof vacuum cleaner• Continuous duty three phase motor• All Stainless Steel AISI 304 construction (AISI 316 electropolished available)• HEPA standard / ULPA Filtration optional• Cleanroom compatible• Available with Liquid bath immersion (for dry recovery only)• Model available for pharmaceutical applications•
CD-4/5/7 EX SeriesDry recoveryLegally certified explosion proof/dust ignition proof vacuum cleaner• Continuous duty three phase motor• All Stainless Steel AISI 304 construction (AISI 316 • electropolished available) HEPA or ULPA Filtration optional • Cleanroom compatible• For dry recovery (liquids can be recovered into a separate • tank)Detachable recovery tank (DT)• Models available for pharmaceutical applications•
CD-IT EX (CFE) HY-C Dry recoveryLegally certified explosion proof/dust ignition proof vacuum • cleaner Continuous duty single and three phase motor• All stainless steel AISI 304 construction (except cart) • For the recovery and neutralization of conductive• and explosive dust into a liquid bathHydraulic cart for easy emptying•
ted Continuous Duty
cleaner
8CD-IT EX (CFE) HY-C
CD-5 EX ARP
CD-3 EX
CD-3 EX CD-4/5/7 CD-IT
Operation60Hz 120, 230,
460 & 575V120, 230,
460 & 575V120, 230,
460 & 575V
50Hz 400V 400V 400V
Filter Cleaning Sysrem
Coalesing Filter element
MFS, MRP, AFS, ARP, RPS Immersion Bath
Recovery tank
capacity
Wet17 gal64l - -
Dry15 gal57l
15-40 gal57-151l
1-2.5 gal3.7-9l
Tools & Accessories Optional Optional Optional
HEPA Filter H14 Included Optional Optional
Electrically Operated Three Phase Series (Europe Only)
9
EUR-HLMT-20L/35L/60L/100L EX DT (MFS)Dry recoveryATEX 100a, 94/9/EC cat. 3 - ATEX Zones 2 (Gas) • and 22 (Dust) potentially explosive atmospheres
Continuous duty three phase motor•
All stainless steel AISI 304 construction(except cart)•
Optional HEPA filter for hazardous locations• (Type H)
Detachable recovery tank (DT)•
EUR/HLMT-35L EX DT (MRP)Dry recoveryATEX 100a, 94/9/EC, cat. 2 - ATEX Zone 1 (Gas) • and Zone 21 (Dust)
Continuous duty three phase motor•
All stainless steel AISI 304 construction(except cart)•
Optional HEPA filter for hazardous locations • (Type H)
Detachable recovery tank (DT)•
y p
9
EUR-HLMT-20L EX DT
EUR-HLMT-35L EX DT
EURHLMT
20L
EURHLMT
35L
EURHLMT
60L
EURHLMT100L
EUR HLMT
35L
Operation @ 50Hz 400V 400V 400V 400V 400V
Filter cleaning system MFS MFS MFS MFS MRP
Recovery tank capacity 25l 35l 60l 100l 35l
Tools & Accessories Optional Optional Optional Optional Optional
HEPA Filter H14 Optional Optional Optional Optional Optional
Number of Filters 2 2 2 2 1
Polyliner & Clip Optional Optional Optional Optional Optional
Electrically Operated Three Phase Series (Europe Only)
10
EUR EX SeriesDry recoveryATEX 100a, 94/9/EC, cat. 2 - ATEX Zone • 1 (Gas) and Zone 21 (Dust). Also available for ATEX Zone 21 (dust) and ATEX Zone 22 (dust)
Continuous duty three phase motor•
All stainless steel AISI 304 construction • (AISI 316L electropolished available)
ULPA filter (Type U) for hazardous • locations
Detachable recovery tank (DT)•
Manual Reverse Purge (MRP) system, • Automatic Reverse Purge (ARP) available
Models available for pharmaceutical • applications
y p
one able one
n
blee
10
EUR-25 EX
EUR-50 EX
EUR-25 EX EUR-50 EX
Operation @ 50Hz 400V 400V
Recovery tank capacitY 25l 51l
Tools & Accessories Optional Optional
ULPA Filter U15 Included Included
Number of Filters 1 1
Polyliner Kit Optional Optional
Pneumatically (Air) Operated Series
11
SSAT-2L & SSAT-6L Dry recovery Legally certified explosion proof/dust ignition • proof vacuum cleaner
Models available in backpack or hand held • configuration
All stainless steel AISI 304 construction•
HEPA standard / ULPA Filtration optional•
Models available for pharmaceutical applications•
SS-IT EX (HY-C) HEPADry recoveryLegally certified explosion proof/dust ignition • proof vacuum cleaner
Meets the requirements for:• Class I – Groups C and DClass II – Groups E, F and G
All stainless steel AISI 304 construction • (except cart)
HEPA standard / ULPA Filtration optional•
For the recovery and neutralization of • conductive and explosive dust into a liquid bath
Hydraulic cart for easy emptying•
Equiped with a coalesing filter element (CFE)•
11
•
•
•
•
•
SSAT-6L BP
SSAT-2L HH
SS-IT EX (HY-C)
SSAT-2L SSAT-6L SS-IT EX
Filter cleaning system - -
Immersion Bath
System
Recovery tank capacity
0.5 gal2l
1.5 gal6l
1-2.5 gal3.7-9l
Tools & Accessories Included Included Included
HEPA Filter H14 Included Included Included
Number of Filters 1 1 1
Pneumatically (Air) Operated Series
12
SS-10/15/25/55 RE HEPA SeriesWet & Dry recoveryLegally certified explosion proof/dust ignition proof • vacuum cleaner
Meets the requirements for:• Class I – Groups C and DClass II – Groups E, F and G.
All stainless steel AISI 304 construction (except • tilt cart).
HEPA standard / ULPA Filtration optional•
Middle Ring with Activated Carbon (MRAC) • available
Based either on a 4 wheel dolly or on a 4 • wheel tilting cart to allow for easy emptying of recovered materials.
Models available for pharmaceutical applications•
SS-55 DMB RE HEPAWet and dry recovery Legally certified explosion proof/dust ignition • proof vacuum cleaner
Meets the requirements for:• Class I – Groups C and DClass II – Groups E, F and G.
All stainless steel AISI 304 construction• (except cart)
HEPA standard / ULPA Filtration optional•
Equiped with dead man brake (DMB)•
Equiped with grounding reel with 50’ stainless • steel cable
12
of
ns
lly (Air) Operated Series
SS-15 (TC) RE
SS-10 (4W) RE
SS-55 (DMB) RE
SS-10 SS-15 SS-25 SS-55
Recovery tank capacity
Wet7.5 gal
28l12.5 gal
47l17 gal64l
45 gal170l
Dry6 gal23l
10 gal38l
15 gal57l
40 gal151l
Tools & Accessories Included Included Included Included
HEPA Filter H14 Included Included Included Included
Number of Filters 3 3 3 3
Pneumatically (Air) Operated Series
13
SS-35L RE HEPA SeriesDry recoveryLegally certified explosion proof/dust ignition • proof vacuum cleaner
Meets the requirements for:• Class I – Groups C and DClass II – Groups E, F and G
All stainless steel AISI 304 construction• (except cart)
HEPA standard / ULPA Filtration optional•
Detachable recovery tank (DT)•
SS-63L RE HEPADry recoveryLegally certified explosion proof/dust ignition • proof vacuum cleaner
Meets the requirements for:• Class I – Groups C and DClass II – Groups E, F and G
Available with single or twin venturi•
All stainless steel AISI 304 construction• (except cart)
HEPA standard / ULPA Filtration optional•
Detachable recovery tank (DT)•
SS-DryLegal• proooff
MMeeet• CClassClass
All sta• (exce
HEPPAA•
DDetac•
SS-DryLeeggal• pproof
Meets•• Class Class
13SS-63L RE MRP
SS-35L RE MRP
SS-35L SS-63L
Filter cleaning system MFS, MRP MFS, MRP
Recovery tank capacity
8.75 gal35l
15.8 gal63l
Tools & Accessories Included Included
HEPA Filter H14 Included Included
Number of Filters 2(MFS) - 1(MRP) 2(MFS) - 1(MRP)
Polyliner & Clip Included Included
Pneumatically (Air) Operated Series
14
SS-20L (DT) RE HEPADry recoveryLegally certified explosion proof/dust ignition • proof vacuum cleaner
Meets the requirements for:• Class I – Groups C and DClass II – Groups E, F and G
All stainless steel AISI 304 construction• (except tilt cart)
HEPA standard / ULPA Filtration optional•
Detachable recovery tank (DT)•
SS-40L (4W) RE HEPADry recoveryLegally certified explosion proof/dust ignition • proof vacuum cleaner
Meets the requirements for:• Class I – Groups C and DClass II – Groups E, F and G
Stainless steel AISI 304 construction•
HEPA standard / ULPA Filtration optional •
Based on a 4 wheel dolly•
Model available for pharmaceutical applications•
Pneumatically (Air) Operated Series
ttiion
tion
4114
SS-20L (DT) RE MFS
SS-40L (4W) RE
SS-20L SS-40L
Filter cleaning system MFS -
Recovery tank capacity
6.25 gal25l
13.5 gal40l
Tools & Accessories Included Included
HEPA Filter H14 Included Included
Number of Filters 2 2
Polyliner & Clip Included Included
Recovery Units
15
IT-25/55Liquid immersion bath to neutralize fine dusts•
All stainless steel AISI 304 construction•
Static dissipating connection hose•
Drain valve for easy disposal of neutralized • recovered material
INT-55All stainless steel AISI 304 construction•
Middle Ring with Activated Carbon (MRAC) • available
Static dissipating connection hose•
Drain valve for easy disposal of recovered • material
Model available for pharmaceutical applications• Model available foorr pharmmaceutical applicatioo••
IT-25
INT-55
Primary Cyclonic Transfer Adaptor
16
AC-25 (4W) EXActivated Carbon system: 25 kg (55lb) of • activated carbon pellets for the adsorption of contaminated fumes and vapours from solvents, fuels and other toxins
All stainless steel AISI 304 construction•
Static dissipating connection hose•
Primary Cyclonic Transfer AdapterA cyclonic adapter ring for 55 gallon drums • allowing for cyclonic separation of particulates through vortex separation
For dry recovery only•
Model available for pharmaceutical applications•
For controlled environments and potentially • explosive atmospheres such as:
Pharmaceutical plants, cleanrooms, * food processing industries, packaging facilitiesIndustries using aluminum, magnesium, and * other commercial alloys in the fabrication of metal products such as powder, ingot, plate, sheet, strip, ribbon, foil, rod, and tubingIndustries involved in the * handling of carbon black, coal, and coke dust
Primary Cyclonic Transfer Adaptor
h ass ppowder, ingot, plate,ffooiill, rod, and tubingnn theblack,
16
AC-25 (4W) EX
PRIMARY CYCLONICTRANSFER ADAPTER
MOUNTED ON 55 GALLON DRUM
Reverse Purge allows for the cleaning of caked-on powder off of the filter cartridge, thus maximizing performance. The filter cleaning is achieved by having the air intake reversed through the filter thus purging the clogged filter. Tiger-Vac offers both manual and automatic reverse purge systems to fit your needs.Our manual system (MRP) operates by closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running and quickly opening the Purge Valve, air will flow backwards through to the filter via the valve removing any caked on dust particles. Our automatic system (ARP) is ideal when the vacuum cleaner will be attached to a processing system and the operator does not have the time to continually perform a manual purge. The cleaning effect occurs from within the filter cartridge, like a cannon blast, for half a second. During that split second, all of the airflow that is located inside of the cartridge is pushed back towards the exterior of the filter cartridge, de-caking the fine dust from off of the cartridge. This effect is called “Cannon Blast Cleaning”.
A full immersion system for hazardous locations, Automatic Purge (APS) consists of a round header tank with fully integrated diaphragm valves, is built inside of the filter chamber. The system operates with filtered, oil-free compressed air. The diaphragm valves are opened in sequence by a solenoid valve controlled by pneumatic (air) operated timers located outside of the filter chamber.A short pulse of compressed air is injected into the top of the static dissipating and conductive PTFE laminated filter cartridges creating a stronger airflow downward moving pressure wave. This wave breaks up the accumulated dust that is caked onto the cartridges. The pneumatically (air) operated controls, located outside of the filter chamber, allow only one cartridge to be cleaned at any given time, thus ensuring that the vacuum cleaner operates continuously.
A reverse pulse filter cleaning system (RPS) for hazardous locations using compressed air and jets operating directly inside the filter cartridge. Located inside of the stainless steel filter chamber, the system is operated by filtered, oil-free compressed air. The frequency of the pulsing air is controlled by pneumatic (air) operated timers located outside of the filter chamber. Short bursts of air are streamed on to the filter freeing the accumulated caked on dust from the static dissipating and conductive PTFE laminated spun bond polyester filter cartridge and allowing them to flow out, thus ensuring continuous duty and minimizing friction loss filter performance. The static dissipating and conductive PTFE laminated spun bond polyester filter cartridge can be easily removed from the filter chamber and safely disposed.
Automatic Filter Shaker system (AFS) for hazardous locations consisting of a double acting air cylinder operating directly onto the stainless steel filter cage located inside of the filter chamber. The system is operated by filtered, oil-free compressed air. The frequency of the shaking cycle is controlled by pneumatic (air) operated timers located outside of the filter chamber. The manual filter shaker system (MFS) consists of a spring action mechanism operating directly onto the fi lter cage located inside of the fi lter chamber. The system is operated by pressing on the ergonomic handle located on the top the filter chamber.Short strokes are applied to the filter cage freeing the accumulated caked on dust from the static dissipating and conductive polyester flourocarbon treated filter and allowing them to flow out, thus ensuring continuous duty and minimizing friction loss filter performance. Included a static dissipating pre-filter for fine dusts. The pre-filter is installed first. It sits on the lip of the tank and is held in place by an elastic. Made of polyester, it is static dissipating and conductive. The Pre-Filter is washable and reusable.The static dissipating and conductive polyester flourocarbon treated filter, along with the stainless steel filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.
Filter Cleaning Solutions
Filter Cleaning by Automatic Purge:
Filter Cleaning by Filter Shaker:
Filter Cleaning by Reverse Pulse:
Filter Cleaning by Reverse Purge:
Available Certification For All European Models
Available Certification For North-American Models
notes
For more information on Tiger-Vac’ products and services,please visit our Web sites:
North America: www.tiger-vac.comEurope: www.tiger-vac.eu
Vacuum Cleaner Systems for Contamination Controlled Environments & Hazardous Locations:
Explosion Proof Vacuum Cleaners
Cleanroom Vacuum Cleaners
Industrial Vacuum Cleaners
Vacuums with Activated Carbon for the adsorption of vapors and odors
Mercury Recovery Vacuum Cleaners
Dustless Vacuum Sanding Solutions
Biohazard, Hospital Grade & Nuclear Grade Vacuum Systems
HEPA & ULPA Filtration
Tiger-Vac Inc. (USA)73 S.W. 12 Ave.
Bldg.1, Unit 7Dania, FL 33004
USATel.: (954) 925-3625Fax: (954) 925-3626
E-mail: [email protected]
Tiger-Vac International Inc.2020 Dagenais Blvd. West
Laval, QuebecCanada H7L 5W2
Tel.: (450) 622-0100Fax: (450) 625-3388
E-mail: [email protected]
Tiger-Vac Europa SrlVia Marie Curie 17
Zona Industriale Ponte Rizzoli40064 Ozzano Emilia BO
ITALIATel.: 39 051 795352
Fax: 39 051 4695077E-mail: [email protected]
Toll free telephone: 1 800 668-4437 (Fax: 1 800 668-4439)http://www.tiger-vac.com
http://www.tiger-vac.eu
exproof booklet/Ver. 1/March. 2009 PrinPrinted ted in Cin Canadanadaa.
ATEX