eximprod grup - erasmus pulse · es200 (eximprod) specific clients rtu (proprietary protocols)...

25
Feb, 2013 EXIMPROD GRUP Business Unit SCADA

Upload: others

Post on 10-May-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Feb, 2013

EXIMPROD GRUP Business Unit SCADA

Page 2: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Summary

SCADA Business Unit Overview

Applications and Case Studies

Software Development

Main Clients and Partners

Page 3: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

SCADA Business Unit Overview

Business Unit established in 2005

Turnover in 2012: 3 mil Euro

Market Share: aprox. 30% of the

Romanian market (Distribution Operators)

Locations:

Main Offices: Bucharest

Other Offices: Buzau, Iasi , Bacau

Page 4: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

SCADA Business Unit within EPG Group

Page 5: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Our Team

18 dedicated engineers

Expertise area: RTU and protection relays,

communications and software

Average age: 29 years

Education: 100% university graduates

(software, energy, automation)

Page 6: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Summary

SCADA Business Unit Overview

Applications and Case Studies

Software Development

Main Clients and Partners

Page 7: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Applications and Case Studies

Pole-Mounted Switches and Reclosers

MV/LV Substations Automation

HV/MV Substations Automation

SCADA DMS/EMS Dispatch Control Centers

Other (wind farm metering, cogeneration

plants, maintenance system, etc)

Applications and Case Studies

Page 8: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Over 1200 in operation in EPG-

installed dispatches

1.000 in operation in third-party

dispatches

Pole-Mounted Switches and Reclosers

Applications and Case Studies

Page 9: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

MV/LV Substation Automation

over 150 Secondary Distribution

Substations (MV/LV) in operation

+ 40 to be commissioned in 2013

Applications and Case Studies

Page 10: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

HV/MV Substations Automation

Over 50 Remote-controlled HV/MV Substations in

operation

Other 50 HV/MV Substations Integrated (general

signaling only)

Local communication protocol diversity

IEC 61850 used mostly since 2009

Applications and Case Studies

Page 11: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

13 Local Dispatcher Control Centers in Operation

Over 1400 Equipment Integrated

Advanced EMS/ DMS Functions in Operation

SCADA DMS/EMS Dispatch Control Centers

Applications and Case Studies

Page 12: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Cogeneration Plant Dispatch

First Dispatch Commissioned in 2010

Integrates the functions from

MV/MV Substation Automation

Local Energy Distribution Operator

Integration

GE Generator

Local DCS System

Water Treatment

Security/Lighting System

Applications and Case Studies

Page 13: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Wind Farm Monitoring and Yield Prognosis

Tower 1, 30 m

0

5

10

15

20

25

01.01.1900 01.03.1900 01.05.1900 01.07.1900 01.09.1900 01.11.1900 01.01.1901 01.03.1901 01.05.1901 01.07.1901 01.09.1901

m/s

Observed GMS MicroCast GMS MICROCOUPLING

Tower 1, 30 m

-5

0

5

10

15

20

25

m/s

GMS MICROCOUPLING Observed

• First Wind Generator Monitoring System

commissioned in 2007

• Yield Prognosis Using Neural Networks

Pilot System set-up in February 2011

Applications and Case Studies

Page 14: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

GIS for SCADA Systems

First Geographical System/SCADA DMS in

operation since 2009

Includes Monitoring Maintenance Teams

Location and Alarm Management

Applications and Case Studies

Page 15: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Technical Expertise Protection relays integrated by EPG:

Distribution Automation Sys. SCADA Sys.

Remote Terminal Units integrated by EPG : Distribution Automation Sys. SCADA Sys.

PolarR (Whipp and

Bourne)

VisionR *(Whipp and

Bourne)

SEL351 * (SEL)

ADVC Controller Nulec *

(Schneider)

Tavrida *

*RTU inclus

REF 541, 542+, 543, 545

(ABB)

REL 511, 670 (ABB)

RET 543, 670 (ABB)

P139, P141 (Areva)

SIPROTEC (Siemens)

M line (Microelecttrica)

D050 (Efacec)

TPU (Efacec)

VAMP (Vamp)

SEPAM (Schneider)

ERBS, DSLPP

(Telecomm)

Power Quality Monitoring

Units

ControlWave (Emerson)

microURR (Efacec)

Arctic Control (Viola

Systems)

Arctic GW 104 I/O (Viola

Systems)

Arctic GW 104 I/O

ES100 (EPG – Viola)

CLP500 (Efacec)

BCU 500 (Efacec)

UAC 420 (Efacec)

Saitel (Telvent)

D400 (GE)

ZIV (Ziv)

Sicam (Siemens)

Talus (Schneider)

ES200 (Eximprod)

Specific clients RTU

(proprietary protocols)

Communication Protocols : Distribution Automation Sys. SCADA Sys.

IEC 60870-5-104

DNP3

Modbus TCP/serial

IEC 60870-5-101/103/104

DNP3

Modbus TCP/serial

IEC 61850 (main protocol since 2009)

Proprietary protocols

Applications and Case Studies

Page 16: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Summary

SCADA Business Unit Overview

Applications and Case Studies

Software Development

Main Clients and Partners

New Developments in 2011

Page 17: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Software Development

ES 100 Modbus/IEC 870-5-104 GPRS Gateway with Linux OS

Pole Mounted Switches automation

Reclosers automation

Small Transformers Substation automation

Optional I/O module

Developed in collaboration with Viola Systems Finland

Software Development

Page 18: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Software Development

ES 200

General RTU Platform

Applications: automation of HV/MV and MV/LV Substations

IEC 870-5-104, DNP 3.0, Modbus

Optional I/O module

HW independent

Windows Embedded OS

KEMA Pretested

Software Development

Page 19: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Summary

SCADA Business Unit Overview

Applications and Case Studies

Software Development

Main Clients and Partners

New Developments in 2011

Page 20: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Romanian Distribution Grid (0,4–

110kV)

Main Clients and Partners

Page 21: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Electrica Romania

- 6 Automation of Distribution Dispatches (aprox. 750 remote-controlled equipment)

- Integrated SCADA DMS System (5 dispatches, 21 substations, integration of 6

Overhead Automation Distribution Systems)

- 1.000 remote-controlled equipment (in third parties dispatches)

E.ON Romania

- Automation of Distribution (400 remote-controlled equipment)

- E.on training Centrer

- SCADA EMS/DMS pilot project (6 Dispatches, Disaster Recovery, 25 substations,

integration of existing systems, SDH telecomunication infrastructure)

Main Clients

Main Clients and Partners

Page 22: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

CEZ Romania

- Automation of 15 secondary distribution substations

- 70 remote controlled overhead switches

ENEL Romania - Automation of Distribution Dispatch (Bucharest Area)

- 70 equipment integrated

Main Clients and Partners

Main Clients (continued)

Page 23: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Main Partners

Efacec Engenharia Portugal

Siemens AG Austria

Viola Systems Finland

General Electric

Al-Pro Gmbh Germany

BU SCADA – Portfolio Overview

Page 24: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Summary

SCADA Business Unit Overview

Applications and Case Studies

Software Development

Main Clients and Partners

Page 25: EXIMPROD GRUP - ERASMUS Pulse · ES200 (Eximprod) Specific clients RTU (proprietary protocols) Communication Protocols : Distribution Automation Sys. SCADA Sys. IEC 60870-5-104 DNP3

Q & A