1 Antonio Valverde Pesticide Residue Research Group University of Almería, Spain Nuevas Guías Europeas de Control de Calidad SANCO Document 12495/2011 on Method Validation and Quality Control Procedures for Pesticide Residues Analysis in Food and Feed EU (D.G. SANCO) tools to assure the Quality of Pesticide Residues Analyses http:/ http:/ www.europa.eu.int www.europa.eu.int/ comm comm/ food food http:/ http:/ www.crl www.crl- pesticides.eu pesticides.eu Method Validation and Quality Control Procedures for Pesticide Residues Analysis in Food and Feed SANCO/12495/2011 (01/01/2012) EU Proficiency Tests for Pesticide Residues in Foods (EU-PTs)

Upload: vannhan

Post on 17-Jul-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

1

Antonio ValverdePesticide Residue Research Group

University of Almería, Spain

Nuevas Guías Europeas de Control de Calidad

SANCO Document 12495/2011 on MethodValidation and Quality Control Procedures forPesticide Residues Analysis in Food and Feed

EU (D.G. SANCO) tools to assure the Qualityof Pesticide Residues Analyses

http:/http:/www.europa.eu.intwww.europa.eu.int//commcomm//foodfoodhttp:/http:/www.crlwww.crl--pesticides.eupesticides.eu

Method Validation and Quality Control Proceduresfor Pesticide Residues Analysis in Food and Feed

SANCO/12495/2011 (01/01/2012)

EU Proficiency Tests for Pesticide Residuesin Foods (EU-PTs)

Page 2: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

2

Document SANCO/12495/2011

Revisions of the SANCO – AQC DocumentThe original document was elaborated by Alan Hill (UK)

1. Doc. 7826/VI/97 (1st EU AQC,1997, Portugal)

2. Doc. SANCO/3103/2000 (2nd EU AQC,1999, Greece)

3. Doc. SANCO/10476/2003 (3rd EU AQC, 2003, UK)

4. Doc. SANCO/10232/2006 (4th EU AQC, 2005, Sweden)

5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain)

6. Doc. SANCO/10684/2009 (6th EU AQC, 2009, Denmark)

7. Doc. SANCO/12495/2011 (7th EU AQC, 2011, France)

httphttp:/:/www.crlwww.crl--pesticides.eupesticides.eu

Page 3: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

3

Document N° SANCO/12495/2011

Key objectives

To harmonize a cost-effective quality assurance system in the EU

To ensure the quality and comparability of analytical results

To ensure that acceptable accuracy is achieved

To ensure that false positives or false negatives are avoided

To support compliance with, and specific implementation of,ISO/IEC 17025 (accreditation standard)

In EU Official Laboratories!

METHOD VALIDATION AND QUALITY CONTROL PROCEDURESFOR

PESTICIDE RESIDUES ANALYSIS IN FOOD AND FEED

Document N° SANCO/12495/20111/January/2012

Introduction (1-4)

Accreditation and legal background (5)

Sampling, transport, processing and storage of samples (6-14)

Pesticide standards, calibration solutions, etc. (15-23)

Extraction and concentration (24-27)

Contamination and interference (28-34)

Analytical calibration, representative analytes, matrix effectsand chromatographic integration (35-53)

Page 4: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

4

Analytical method validation and performance criteria (54-60)

Routine recovery determination (61-67)

Proficiency testing and analysis of reference materials (68-69)

Confirmation of results (70-81)

Reporting of results (82-93)

Annex 1 (Selection of matrices)

Appendix A (The validation procedure: outline and example approaches)

Appendix B (Examples of conversion factors)

Appendix C (Examples for estimation of measurement uncertainty)

Appendix D (Glossary)

Appendix E (Data elements of the Standard Sample Description)

Document N° SANCO/12495/2011

may = option

should = recommendation

must = obligation

Key for the interpretation of the documentSANCO/12495/2011

(Appendix D: Glossary)

Page 5: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

5

Representative matrices may be used.

As a minimun, one matrix from each Commodity Group.

Complementary validation during the routine analyses.

Validation

Document N° SANCO/12495/2011

- High water content

- High oil content

- High starch and/or protein content (low water & fat content)

- High acid content (and high water content)

- High sugar content (and low water content)

- Difficult or unique commodities

VEGETABLES, FRUITS, and CEREALS (6 Groups)

Validation10 Commodity Groups for Representative Matrices

(Annex 1)

Document N° SANCO/12495/2011

Page 6: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

6

- Meat and Seafood

- Milk and milk products

- Eggs

- Fat from food of animal origin

FOOD OF ANIMAL ORIGIN (4 Groups)

Validation10 Commodity Groups for Representative Matrices

(Annex 1)

Document N° SANCO/12495/2011

Document N° SANCO/12495/2011: Annex 1 (Based on the OECD criteria)

Page 7: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

7

Document N° SANCO/12495/2011: Annex 1

Document N° SANCO/12495/2011: Annex 1

Page 8: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

8

Validation Parameters and Criteria(Quantitative Methods)

Appendix A: Outline and Example

Document N° SANCO/12495/2011

2 Fortification Levels for each Representative Matrix:

- Reporting Limit (n = 5)

- Another higher level / MRL (n = 5)

Minimun Validation Criteria(Quantitative Methods)

For each Fortification Level/Representative Matrix*:

- Mean Recovery = 70-120 %

- RDSwr & RSDwR ≤ 20 %

* In certain justified cases different values may be accepted

Document N° SANCO/12495/2011

Page 9: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

9

Ejemplo Estudio Validación Forchlorfenuron(QuEChERS/LC-TOF-MS)

MATRICES REPRESENTATIVASSandía

CalabacínTomate

Forchlorfenuron TOF-MS

Page 10: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

10

Patrón Forclorfenuron 0.01 mg/kg en extracto de calabacínLC-TOF-MS (XIC: 248.0 – 248.2 amu)

Patrón Forclorfenuron 0.01 mg/kg en extracto de calabacínTOF-MS a 20.89 min.

Page 11: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

11

Estudio Validación Forchlorfenuron(QuEChERS/LC-TOF-MS)

LinealidadEfecto Matriz

Recuperación

Secuencia cromatográficarecuperaciones 10 ng/g

1) Matrix blank2) 10 ng/g STD3) Spike Sample #14) Spike Sample #25) Spike Sample #36) Spike Sample #47) Spike Sample #58) 10 ng/g STD9) 50 ng/g STD10) 100 ng/g STD11) 200 ng/g STD12) 500 ng/g STD13) Solvent

1

5

6

10

11

15

16

10 ng/g

200 ng/g

50 ng/g

Page 12: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

12

Resultados Ensayos de Recuperación

Nº Total Recuperaciones = 45Intervalo Recuperaciones Individuales = 60% - 95%Recuperación Media = 72%; RSD = 12%U (expandida) = 24%

Relación S/N: Sandía = 350 – 600Calabacín = 110 – 130Tomate = 70 – 110

Recuperaciones Medias 10 ng/g > 71%

RSD Recuperaciones 10 ng/g < 10%

Error Masa Exacta < 0.5 ppm

LOQ Validado = 10 ng/g

LOD (cualitativo) diana a validar = 0.5 ng/g

Resumen Resultados Estándares (matriz) y Recuperaciones 10 ng/g

Concentración estimada para dar una S/N 3-5 en la matriz menos favorable (tomate)

Page 13: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

13

ValidationQualitative Screening Methods

(MS-based detection)

Validation of qualitative MRMs is focused on detectability

The Screening Detection Limit (SDL) is the lowest concentration forwhich the analyte can be detected in at least 95% of the samples

A basic validation should involve analysis of at least 20 samplesspiked at the anticipated SDL (for each commodity group)

Negative results must be reported as < SDL mg/kg

Positive results can only be reported after quantitative analysis

Document N° SANCO/12495/2011

On-going performance VerifactionQualitative Screening Methods

(MS-based detection)

At least 10 indicator analytes should be checkedwith each analytical batch

Document N° SANCO/12495/2011

Page 14: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

14

Analytical Calibration

Routine Recovery Determination(On-going Performance Verification/Validation)

Confirmation of Results

Key Activities for Quality ControlSANCO/12495/2011

- Standards in matrix, if appropriate

- Alternative use of “analyte protectants” in GC

- Alternative (recommended) use of “standard addition”

- Calibration in each batch of analysis

- Bracketing calibration (< 20% - 30% drift)

- Residues below LCL* should be reported as < LCL

- LCL Signal/Noise ≥ 6:1

*LCL = Lowest Calibrated Level

Analytical Calibration

Document N° SANCO/12495/2011

Page 15: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

15

Interpolation between 2 Calibration Levels- Difference between levels not greater than a factor of 4- Higher RF/Lower RF < 120% (110% if MRL is exceeded)

Multilevel Calibration Function- Individual residuals must not deviate more than ±20% (10%)

Single-Level Calibration- May provide more accurate results- Sample response should be within ±50% of the cal. (20%)

Analytical CalibrationDocument N° SANCO/12495/2011

Minimun frequencies for calibration

A minimun number of Representative Analytes per detectionsystem MUST BE used for calibration in each batch

Representative Analytes ≥ 15 + 25% Tested Analytes

Document N° SANCO/12495/2011

Page 16: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

16

Example on the minimun number of RepresentativeAnalytes for Calibration

Analytical Scope with 140 pesticides(40 by LC + 100 by GC)

Document N° SANCO/12495/2011

Representative Analytes in LC = 15 + 10 25

Representative Analytes in GC = 15 + 25 40

Routine Recovery Determination(On-going performance verification / validation)

Document N° SANCO/12495/2011

- Ensure the validity of the results during routine analysis

- Determine within-laboratory reproducibility (RSDwR)

- Determine acceptable limits for individual recoveries

- Demonstrate applicability to other commodities / levels

- Demostrate robustness

- Collect information for uncertainty estimation

Page 17: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

17

Frequencies for Routine Recovery(On-going performance verification)

Recoveries must be checked in each analytical batchfor, at least, 10% of the Representative Analytes

with a minimun of 5 analytes per detection system

Document N° SANCO/12495/2011

Example on the minimun number Analytesfor Routine Recovery

Analytical Scope with 140 pesticides(40 by LC + 100 by GC)

RepresentativeRepresentativeRepresentative AnalytesAnalytesAnalytes in LCin LCin LC = 15 + 10 = 25= 15 + 10 = 25= 15 + 10 = 25RepresentativeRepresentativeRepresentative AnalytesAnalytesAnalytes in GCin GCin GC = 15 + 25 = 40= 15 + 25 = 40= 15 + 25 = 40

Document N° SANCO/12495/2011

Routine Recovery Analytes in LC = 2.5 5

Routine Recovery Analytes in GC = 4 5

Page 18: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

18

Mean Recovery ± 2 x RSD(calculated from results of different matrices for each commodity group)

but

a generalized range of 60-140 % may be used

Acceptable Limits for Routine Recovery

Document N° SANCO/12495/2011

Acceptable Limits for Routine Recovery(mean recovery ± 2xRSD)

72 - 16866 - 15460 - 14054 - 12648 - 11242 - 9820%84 - 15677 - 14370 - 13063 - 11756 - 10449 - 9115%96 - 14488 - 13280 - 12072 - 10864 - 9656 - 8410%

108 - 13299 - 12190 - 11081 - 9972 - 8863 - 775%Acceptable recovery range for individual recoveries (%)RSD*

120%110%100%90%80%70%Mean recovery*

* From on-going validation of year before (if not available: from initial validation)

This Table was not included in the final version of the Document!

Page 19: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

19

75. ... the relative retention time of the analyte should correspond tothat of the calibration solution witha tolerance of ±0.5% for GC and±2.5% for LC.

Confirmation of resultsRequirements for Chromatography

Document N° SANCO/12495/2011

Confirmation of resultsRequirements for Mass Spectrometry (MS)

Document N° SANCO/12495/2011

Page 20: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

20

Confirmation of resultsRequirements for Mass Spectrometry (MS)

Document N° SANCO/12495/2011

Using matrix-matched calibration standards at comparable concentrations

91.Considering the results obtained to date from EU proficiency tests, a default expanded uncertaintyfigure of 50% (corresponding to a 95% confidencelevel and a coverage factor of 2), in general covers the inter-laboratory variability between theEuropean laboratories and is recommended to be used by regulatory authorities in cases of enforcement decisions (MRL-exceedances).

Reporting of resultsInterpretation of results for enforcement purposes

Document N° SANCO/12495/2011

Page 21: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

21

“European Proficiency Tests” EUPTs (FV9 – FV11)

93. If required, the result should be reported together with theexpanded uncertainty (U), as follows: Result = x ± U (units), with x representing the measured value. In case of official food control by regulatory authorities, compliance with the MRL has to be checked by assuming that the MRL is exceeded if themeasured value exceed the MRL by more than the expanded uncertainty (x – U > MRL).

Reporting of resultsInterpretation of results for enforcement purposes

Document N° SANCO/12495/2011

93. … With this decision rule, the value of the measurand is abovethe MRL with at least 97.5% confidence.

Page 22: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

22

mg

kg-1

Results with Uncertainty (50%)(k = 2; 95%)

1.0

1.8

1.4

2.2

2.4Results without Uncertainty

MRL = 1.00 mg/kg

No violativeViolative

1.65 mg/kg

2.01 mg/kg

1.65 mg/kg

2.01 mg/kg

With this SANCO/12495/2011 “Decision Rule”,a result (X) will be violative when X > 2 MRL

(assuming an expanded uncertainty of 50%)

Page 23: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

23

We need additional informationto take a DESISION

Confidence in a CORRECT DECISION!

Page 24: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

24

““QualityQuality”” of (of (““ConfidenceConfidence”” on) the Resulton) the Result

0.85 ± 0.30 mg/kg (95%)

0.85 ± 0.10 mg/kg (¿50%?)

0.85 mg/kg (¿10%?) Value

with precision

with uncertainty K=2

Standard Uncertainty (uucc)

(U = (U = kk x x uucc))

0.845 - 0.854

0.75 - 0.95

1.15 - 0.55

Reported ResultConfidenceLevel

“DESISION RULES”

“PROBABILITY OF CORRECT DECISION”

Page 25: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

25

“Decision Limit” for “Rejection”

- Non-Compliant if X - U > MRL

DECISION FOR CORRECT REJECTION (97.5%)

93. … the MRL is exceeded if the measured valueexceed the MRL by more than the expandeduncertainty (x – U > MRL). With this DECISION

RULE, the Probabiltity ofcorrect REJECTION is:

> 97.5%

SANCO/12495/2011 DECISION RULE for REJECTION

If U = 50% “Decision Limit” = 2 x MRL

97.5%

2.5%

Compliant with an upper limit ifthe measured value plus theexpanded uncertainty (k = 2, 95%) is bellow the limit.

With this DECISION RULE, the Probabiltity of correctACCEPTANCE is > 97.5%

A similar (95% confidence) DECISION RULE forcorrect ACCEPTANCE (by producers?)

“Decision Limit” for “Acceptance”

- Compliant if X + U < MRL

DECISION FOR CORRECT ACCEPTANCE (97.5%)

97.5%

2.5%

Page 26: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

26

(MRL)

U (K = 2; 95%)

High confidence ofcorrect REJECTION (>97.5%)

High confidence ofcorrect ACCEPTANCE (>97.5%)

REJECTION by Official Control Authorities

ACEPTANCE by Producers

MRL COMPLIANCE

Authorities and/or Producers must fix the confidence degreeof their DECISION before establishing the “DECISION RULE”

U (K = 2; 95%)

Appendix C:Examples for the estimation of mesurement uncertainty

Document N° SANCO/12495/2011

CAC/GL 59CAC/GL 59--20062006GuidelinesGuidelines onon EstimationEstimation ofof UncertaintyUncertainty ofof ResultsResults

GuidelinesGuidelines -- Codex Codex AlimentariusAlimentarius

Amendment 2011

Introduction of an ANNEX with some examples on practical aproaches for theestimation of uncertainty of results in pesticide residue tests (CX/PR 11/43/10)

CCPR 43rd Session (Beijing, P.R. China, 4-9 April 2011)

Page 27: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

27

CAC/GL 59-2006 – Amendment 2011 (Annex)

Concentration-Dependent Formula (HORWITZ)

Default-Fixed Value (50% / EU)1

2

u´ = (u´Rw2 + + u´bias

2)1/2

(u´bias)PT

(u´bias)QCNo-correction

(u´bias)QCMean Rec. Correction

Intra-Laboratory Validation/QC/PTs Data3

Relative intra-laboratoryreproducibility SD (QC)

u´(Cref)PTRoot Mean Squareof relative PTs bias

Root Mean Squareof relative QC bias u´(Cref)QC

a

b

c u´(Cref)QC

&

&

&u´(Mean Rec.)QC

u´Rw / n1/2

(∑(bias)2/n)1/2

CAC/GL 59-2006 – Amendment 2011 (Annex)

Page 28: EU (D.G. SANCO) tools to assure the Quality of Pesticide ... · SANCO/10232/2006 (4th EU AQC, 2005, Sweden) 5. Doc. SANCO/2007/3131 (5th EU AQC, 2007, Spain) 6. Doc. SANCO/10684/2009

28

Many thanks for your attention