  • 7/24/2019 ETERNUS Configuration Guide

    1/42

    ETERNUS

    [Specification]

    (1) ETERNUS DX60 S2 1(2) ETERNUS DX80 S2 2

    (3) ETERNUS DX90 S2 3(4) Supported RAID 4

    [Outline]

    (1) View 5(2) Product Diagrams 7

    [System configuration tree diagram]

    (1) ETERNUS DX60 S2 (Dual-controller type) 9(2) ETERNUS DX60 S2 (Single-controller type) 11(3) ETERNUS DX80 S2 (Dual-controller type) 14(4) ETERNUS DX80 S2 (Single-controller type) 17(5) ETERNUS DX90 S2 (Dual-controller type) 20(6) ETERNUS DX90 S2 (Single-controller type) 23

    (7) Options 26(8) Cables 39(9) Rack 40

    (10) ETERNUS Multipath Driver 41

    Product ID/Descriptions Meaning of each circle ()Each product has "Product Description", "ProductID" => Only one selection can be madeand "Brief Remarks" as follows. =>Multiple selections are possible.

    (There may be some restriction)Ex) Product name

    Drive enclosure

    - Rackmount type 2U

    ETLDE2AU

    Product ID Brief Remarks

    Copyright 2013 FUJITSU LIMITED

    System Configuration Guide February 2013, 6th editionCONTENTS

    ETERNUS DX 60 S2, DX80 S2, DX90 S2 Disk Storage Systems

    Se

    lectonly

    Con

    current

    connections

    perm

    itted

  • 7/24/2019 ETERNUS Configuration Guide

    2/42

    SINGLE

    CONTROLLER

    DUAL

    CONTROLLER

    SINGLE

    CONTROLLER

    DUAL

    CONTROLLER

    Physical capacity *2

    Logical capacity *3

    1 2 1 2

    2 4 2 4

    1GB 2GB 1GB 2GB

    Capacity (rotation speed)

    Drive interface

    Capacity (rotation speed)

    Drive interface

    Capacity

    Drive interfaceCapacity (rotation speed)

    Drive interface

    Capacity (rotation speed)

    Drive interface

    Capacity

    Drive interface

    Controller Enclosure

    Drive Enclosure

    Controller Enclosure

    Drive Enclosure

    Voltage

    Phase

    Frequency

    Controller Enclosure

    Drive Enclosure

    Controller Enclosure

    Drive Enclosure

    Temperature

    Humidity

    *1: Storage capacity depends on which HDDs are mounted.

    *2: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.

    *3: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.

    User area capacity differs depending on the environment.

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    Number of controllers

    Host Interfaces

    Fibre Channel (Max. 4Gbit/s)

    iSCSI (Max. 1Gbit/s)

    SAS (Max. 3Gbit/s)

    Number of host interfaces

    Number of connectable hosts 32, 64 (2, 4 for SAS connection)

    (1) ETERNUS DX60 S2 Speci fic ation

    Product name ETERNUS DX60 S2

    2.5" MODEL 3.5" MODEL

    Supported RAID levels 0, 1, 1+0, 5, 5+0, 6

    Storage Capacity *1 Max. 24.0TB Max. 72.0TB

    Max. 17.8TB Max. 53.4TB

    Cache memory capacity

    Number of drives 2 - 24

    Disk Drives

    3.5"

    SAS disk drive

    3.5" nearline

    SAS disk drive

    3.5" SSD -

    -2.5"

    SAS disk drive

    2.5" SSD -

    -

    -

    -

    -

    -

    900GB, 600GB,450GB,300GB(10,000rpm)

    SAS (Max. 3Gbit/s)

    600GB, 450GB, 300GB (15,000rpm)

    SAS (Max. 3Gbit/s)

    3TB, 2TB, 1TB (7,200rpm)

    SAS (Max. 3Gbit/s)

    -

    35 kg

    Power

    AC 100 - 120 V / AC 200 - 240 V

    Single

    50 Hz / 60 Hz

    Dimensions (W x D x H)- 483 650 88 mm (2U)

    Maximum W eight

    (per one Enclosure) - 35 kg

    -

    Environmental Conditions 10 - 40 C (Operating), 0 - 50 C (Non-operating)

    20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)

    483 650 88 mm (2U) 483 650 88 mm (2U)

    35 kg

    440W (450VA) [1,590kJ/h]

    370W (380VA) [1,340kJ/h]

    430W (440VA) [1,550kJ/h]

    - 370W (380VA) [1,340kJ/h]

    2.5" nearline

    SAS disk drive

    -

    -

    1TB (7,200rpm)

    SAS (Max. 3Gbit/s)

    Maximum Power

    Consumption

    [Maximum Heat

    Generation]

    AC100-120V

    AC200-240V

    510W (520VA) [1,840kJ/h]

    -

    500W (510VA) [1,800kJ/h]

    1

  • 7/24/2019 ETERNUS Configuration Guide

    3/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    SINGLE

    CONTROLLER

    DUAL

    CONTROLLER

    SINGLE

    CONTROLLER

    DUAL

    CONTROLLER

    Physical capacity *3

    Logical capacity *4

    1 2 1 2

    2 / 4 4 / 8 2 / 4 4 / 8

    2GB 4GB 2GB 4GB

    Capacity (rotation speed)

    Drive interface

    Capacity (rotation speed)Drive interface

    Capacity

    Drive interface

    Capacity (rotation speed)

    Drive interface

    Capacity (rotation speed)

    Drive interface

    Capacity

    Drive interface

    Controller Enclosure

    Drive Enclosure

    Controller Enclosure

    Drive Enclosure

    Voltage

    Phase

    Frequency

    Controller Enclosure

    Drive Enclosure

    Maximum configuration

    Controller Enclosure

    Drive Enclosure

    Maximum configuration

    Temperature

    Humidity

    *1: 2.5" base unit items are based on configuration with 2.5" drive enclosures only.

    *2: Storage capacity depends on which HDDs are mounted.

    *3: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.*4: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.

    User area capacity differs depending on the environment.

    *5: Mixtures of 2.5" and 3.5" drives are supported by adding both 2.5" and 3.5" drive enclosures.

    800GB, 400GB, 200GB, 100GB

    Single

    50 Hz / 60 Hz

    AC 100 - 120 V / AC 200 - 240 V

    35 kg 35 kg

    Dimensions (W x D x H)

    10 40 C (Operating), 0 - 50 C (Non-operating)

    20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)

    2-120

    Environmental Conditions

    600GB, 450GB, 300GB (15,000rpm)

    Power

    2.5"

    SAS disk drive

    Disk Drives

    3.5" SSD

    3.5"

    SAS disk drive

    2.5" SSD

    SAS (Max. 6Gbit/s)

    Number of drives

    SAS (Max. 6Gbit/s)

    SAS (Max. 6Gbit/s)

    3.5" nearlineSAS disk drive

    482 645 88 mm (2U) 482 670 88 mm (2U)

    482 540 88 mm (2U) 482 555 88 mm (2U)

    Host Interfaces

    900GB, 600GB,450GB,300GB(10,000rpm)

    SAS (Max. 6Gbit/s)

    Number of host interfaces

    2.5" MODEL *1

    800GB, 400GB, 200GB, 100GB

    SAS (Max. 6Gbit/s)

    3TB, 2TB, 1TB (7,200rpm)

    3.5" MODEL

    Number of connectable hosts

    ETERNUS DX80 S2

    Supported RAID levels

    Maximum

    Power

    Consumption

    [Maximum

    Heat

    Generation]

    AC100 - 120V

    AC200 - 240V

    630W (640VA) [2,300kJ/h]

    570W (580VA) [2,100kJ/h]

    620W (630VA) [2,300kJ/h]

    550W (560VA) [2,000kJ/h]

    5,570W (5,670VA) [20,300kJ/h]

    630W (640VA) [2,300kJ/h] 610W (620VA) [2,200kJ/h]

    570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]

    5,560W (5,660VA) [20,200kJ/h]

    Maximum W eight

    (per one Enclosure) 35 kg 35 kg

    Storage Capacity *2

    iSCSI (Max. 1Gbit/s)

    Max. 1,024

    iSCSI (Max. 10Gbit/s)

    SAS (Max. 6Gbit/s)

    FCoE (Max. 10Gbit/s)

    2.5" nearline

    SAS disk drive

    1TB (7,200rpm)

    SAS (Max. 6Gbit/s)

    (2) ETERNUS DX80 S2 Speci fic ation

    0, 1, 1+0, 5, 5+0, 6

    Fibre Channel (Max. 16Gbit/s)

    Number of controllers

    Cache memory capacity

    Product name

    Max. 360.0TB

    Max. 267.0TB

    2

  • 7/24/2019 ETERNUS Configuration Guide

    4/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    SINGLE

    CONTROLLER

    DUAL

    CONTROLLER

    SINGLE

    CONTROLLER

    DUAL

    CONTROLLER

    Physical capacity *3

    Logical capacity *4 1 2 1 2

    2 / 4 4 / 8 2 / 4 4 / 8

    4GB 8GB 4GB 8GB

    Capacity (rotation speed)

    Drive interface

    Capacity (rotation speed)

    Drive interfaceCapacity

    Drive interface

    Capacity (rotation speed)

    Drive interface

    Capacity (rotation speed)

    Drive interface

    Capacity

    Drive interface

    Controller Enclosure

    Drive Enclosure

    Controller Enclosure

    Drive Enclosure

    VoltagePhase

    Frequency

    Controller Enclosure

    Drive Enclosure

    Maximum configuration

    Controller Enclosure

    Drive Enclosure

    Maximum configuration

    Temperature

    Humidity

    *1: 2.5" base unit items are based on configuration with 2.5" drive enclosures only.

    *2: Storage capacity depends on which HDDs are mounted.

    *3: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.

    *4: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.User area capacity differs depending on the environment.

    *5: Mixtures of 2.5" and 3.5" drives are supported by adding both 2.5" and 3.5" drive enclosures.

    50 Hz / 60 Hz

    SAS (Max. 6Gbit/s)

    900GB, 600GB,450GB,300GB(10,000rpm)

    SAS (Max. 6Gbit/s)

    482 555 88 mm(2U)

    2.5"

    SAS disk drive

    3.5" SSD

    Power

    Dimensions (W x D x H)

    2.5" SSDSAS (Max. 6Gbit/s)

    AC 100 - 120 V / AC 200 - 240 V

    Single

    35 kg

    35 kg 35 kg

    Maximum W eight

    (per one Enclosure)

    35 kg

    482 645 88 mm(2U)

    482 540 88 mm(2U)

    482 670 88 mm(2U)

    Disk Drives

    3.5"

    SAS disk drive

    2.5" nearline

    SAS disk drive

    600GB, 450GB, 300GB (15,000rpm)

    Cache memory capacity

    Number of connectable hosts

    SAS (Max. 6Gbit/s)

    2.5" MODEL *1 3.5" MODEL

    iSCSI (Max. 10Gbit/s)

    ETERNUS DX90 S2

    Max. 360.0TB

    Max. 267.0TB

    iSCSI (Max. 1Gbit/s)

    Number of controllers

    Fibre Channel (Max. 16Gbit/s)

    Number of host interfaces

    Host Interfaces

    Max. 1,024

    (3) ETERNUS DX90 S2 Speci fic ation

    SAS (Max. 6Gbit/s)

    FCoE (Max. 10Gbit/s)

    Storage Capacity *2

    0, 1, 1+0, 5, 5+0, 6Supported RAID levels

    Product name

    800GB, 400GB, 200GB, 100GB

    Environmental Conditions20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)

    2-240 2-120

    10 - 40 C (Operating), 0 - 50 C (Non-operating)

    Maximum

    Power

    Consumption

    [Maximum

    Heat

    Generation]

    AC100 - 120V

    630W (640VA) [2,300kJ/h] 620W (630VA) [2,300kJ/h]

    570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]

    5,760W (5,860VA) [21,200kJ/h]

    AC200 - 240V

    630W (640VA) [2,300kJ/h] 610W (620VA) [2,200kJ/h]

    570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]

    5,760W (5,860VA) [21,200kJ/h]

    3TB, 2TB, 1TB (7,200rpm)

    SAS (Max. 6Gbit/s)800GB, 400GB, 200GB, 100GB

    3.5" nearline

    SAS disk drive

    Number of drives

    1TB (7,200rpm)

    SAS (Max. 6Gbit/s)

    3

  • 7/24/2019 ETERNUS Configuration Guide

    5/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    The ETERNUS DX60 S2/DX80 S2/DX90 S2 support the following RAID levels.

    Use of RAID0 is not recommended because it is not redundant.For RAID0 configurations, data may be lost due to disk drive failure.

    Recommended number disk drives

    RAID0 2 - 16 2 - 16 *1

    RAID1 2 2 2 (1Data + 1Mirror)RAID1+0 4 - 24 4 - 32 4 (2Data + 2Mirror)

    6 (3Data + 3Mirror)8 (4Data + 4Mirror)

    10 (5Data + 5Mirror)RAID5 3 - 16 3 - 16 3 (2Data + 1Parity)

    4 (3Data + 1Parity)5 (4Data + 1Parity)6 (5Data + 1Parity)

    RAID5+0 (3 - 12) x 2 (3 - 16) x 2 3 (2Data + 1Parity) x 24 (3Data + 1Parity) x 25 (4Data + 1Parity) x 26 (5Data + 1Parity) x 2

    RAID6 5 - 16 5 - 16 5 (3Data + 2Parity)6 (4Data + 2Parity)7 (5Data + 2Parity)

    *1: Use of RAID0 is not recommended because it is not redundant.

    ETERNUS DX80 S2ETERNUS DX90 S2

    Supported number disk drives

    RAID level

    (4) Suppo rted RAID

    ETERNUS DX60 S2

    4

  • 7/24/2019 ETERNUS Configuration Guide

    6/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    (1) ETERNUS DX60 S2 View

    - Base unit

    Front Cover

    Controller (Standard)(Additional Controller (Option))

    Host Interface (Standard)

    AC power cable (200V)(Standard)

    LAN port

    Drive interface (OUT) portPower Supply Unit (Standard)

    Base unit rear view

    - Drive Enclosure

    Front Cover

    Drive interface (OUT) portDrive interface (IN) port

    AC power cable (200V)(Standard)

    Power Supply Unit (Standard)

    Drive Enclosure r ear view

    Drive Enclosure front view(3.5" type)

    ETERNUS DX60 S2 View

    Base unit front view Base unit front view(3.5" type) (2.5" type)

    5

  • 7/24/2019 ETERNUS Configuration Guide

    7/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    (2) ETERNUS DX80 S2, DX90 S2 View

    - Base unit (Controller Enclosure)

    3.5" disk 2.5" disk

    Controller (Standard)(Additional Controller (Option))

    Host Interface (Standard)

    AC power cable (200V)(Standard)

    LAN port

    Drive interface (OUT) portPower Supply Unit (Standard)

    Base unit rear view

    - Drive Enclosure

    3.5" disk 2.5" disk

    Drive interface (OUT) portDrive interface (IN) port

    AC power cable (200V)(Standard)

    Power Supply Unit (Standard)

    Drive Enclosure r ear view

    (3.5" type) (2.5" type)

    ETERNUS DX80 S2, DX90 S2 View

    Base unit front view Base unit front view(3.5" type) (2.5" type)

    Drive Enclosure front view Drive Enclosure front view

    6

  • 7/24/2019 ETERNUS Configuration Guide

    8/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    *1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.

    (Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)*2: The following table shows the type and number of drive enclosures that can be installed in DX60 S2.

    3.5" type

    2.5" type

    ETERNUS DX60 S2 Product Diagrams

    Base unit Drive Enclosure

    3.5" type 2.5" type

    ETERNUS DX60 S2 Max. 1 Not supported

    Not supported Not supported

    Server

    ETERNUS DX60 S2 base unit

    Disk Drive (Option) (Max, 12/24 drives can be installed *1)

    ......

    AC power cable 200V 4m x2

    Power distribution unit (AC200V) (Option)

    3.5" Drive Enclosure (Option) *2

    Disk Drive (Option) (Max, 12 drives can be installed)

    ......

    AC power cable 200V 4m x2

    Power distribution unit (AC200V)(Option) (Share with base unit)

    SAS cable (0.75m) x2(Attached to Drive Enclosure)

    LAN cable (category 5e) 5m x 2(Setup node/Management LAN

    Connection)(Option)

    Host Interface cable (Option)FC cable (5m) x 2

    LAN cable (category 5e)(5m) x2SAS cable (1.5m) x2

    Host interface(Standard/Option)

    HBA (Host Bus Adaptor):FC / SAS / LAN card

    Extension cable (Option)SAS cable (3m or 6m) x2(Order when standard cable is too short)

    Controller Enclosure(Standard)

    Controller Enclosure(Standard/Option)

    Host interface(Standard)

    7

  • 7/24/2019 ETERNUS Configuration Guide

    9/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    Host Interface Option(At least one set of Host interfaces is mandatory forsingle-controller model. And two of the same hostinterface sets are mandatory for dual-controller.)- Fibre Channel- SAS

    - iSCSI (1Gbit/s)- iSCSI (10Gbit/s)

    - FCoE

    *1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)

    *2: Mixture of 3.5" type drive enclosures and 2.5" type drive enclosures enablesmixture of 3.5" drives and 2.5" drives in the same machine.Up to 120 drives can be installed in a single ETERNUS DX80 S2.

    Up to 240 drives can be installed in a single ETERNUS DX90 S2.The following table shows the type and number of drive enclosures that can be installed in DX80 S2/DX90 S2.

    3.5" type2.5" type3.5" type

    2.5" type

    ETERNUS DX80 S2, DX90 S2 Product Diagrams

    ETERNUS DX90 S2 Max. 9 Max. 9

    Max. 9 Max. 9

    ETERNUS DX80 S2

    Base unit

    Drive Enclosure

    Server

    2.5" type3.5" type

    Max. 9Max. 9

    Max. 4Max. 4

    ETERNUS DX80 S2, DX90 S2 base unit

    Disk Drive (Option) (Max, 12/24 drives can be installed *1)

    ......

    Controller Enclosure(One option must be chosen)

    AC power cable 200V 4m x2

    IEC cable x2 (Option)

    Power distribution unit (AC200V)

    (Option)

    Drive Enclosure (Option)Total four/nine DE (2.5"/3.5") can be installed. *2

    Disk Drive (Option) (Max, 12/24 drives can be installed *1)

    ...... Power distribution unit (AC200V)(Option) (Share with base unit)

    SAS cable (0.75m) x2(Attached to Drive Enclosure)

    LAN cable (category 5e) 5m x 2(Setup node/Management LAN

    Connection)(Option)(Remote monitoring function requires additional LAN

    HBA (Host Bus Adaptor):FC / SAS / LAN / FCoE card

    Extension cable (Option)SAS cable (3m or 6m) x2(Order when standard cable is too short)

    Thin Provisioning Feature (Option)(Max. one license can be installed)

    AC power cable 200V 4m x2

    IEC cable x2 (Option)

    Controller Enclosure(One option must bechosen)

    8

  • 7/24/2019 ETERNUS Configuration Guide

    10/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    i) ETERNUS DX60 S2 base unit (Dual controller type, Fibre Channel connection)

    Rackmount type (2U), AC200V model

    Enclosure x1- Controller (FC4Gbit/s x 2ports) x2- Cache memory (1G) x2- Power Supply Unit x2

    At least two disk drives are mandatory. Up to 24 drives can be added.Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.

    2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.

    - Contents of Package

    Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)

    Rack mount kit 1 set

    Safety Precautions 1User Guide 1 CDRead me first 1

    ii) ETERNUS DX60 S2 base unit (Dual controller type, SAS connection)

    Rackmount type (2U), AC200V modelEnclosure x1

    - Controller (SAS x 2ports) x2- Cache memory (1G) x2- Power Supply Unit x2

    At least two disk drives are mandatory. Up to 24 drives can be added.

    Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.

    - Contents of Package

    Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1

    (1) ETERNUS DX60 S2 (dual-controller type)

    Components

    ETERNUS DX60 S2

    (2.5inch, 4Gbps, FC, dual-controller)ET062DCFU

    ETERNUS DX60 S2

    (3.5inch, 4Gbps, FC, dual-controller)ET062DDFU

    Product name

    Product ID

    Configuration

    Notes

    Components

    ETERNUS DX60 S2

    (2.5inch, 3Gbps, SAS, dual-controller)

    ETERNUS DX60 S2

    (3.5inch, 3Gbps, SAS, dual-controller)ET062DCSU ET062DDSU

    Product name

    Product ID

    Configuration

    Notes

    9

  • 7/24/2019 ETERNUS Configuration Guide

    11/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(1) ETERNUS DX60 S2 (dual-controller type)

    iii) ETERNUS DX60 S2 Base Unit (Dual controller type, iSCSI connection)

    Rackmount type (2U), AC200V modelEnclosure x1

    - Controller (iSCSI x 2ports) x2- Cache memory (1G) x2- Power Supply Unit x2

    At least two disk drives are mandatory. Up to 24 drives can be added.

    Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.

    - Contents of Package

    Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)

    Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1

    Components

    ETERNUS DX60 S2

    (2.5inch, 1Gbps, iSCSI, dual-ET062DCLUProduct ID

    Configuration

    Notes

    ETERNUS DX60 S2

    (3.5inch, 1Gbps, iSCSI, dual-ET062DDLU

    Product name

    10

  • 7/24/2019 ETERNUS Configuration Guide

    12/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    i) ETERNUS DX60 S2 base unit (Single controller type, Fibre Channel connection)

    Rackmount type (2U), AC200V model

    Enclosure x1- Controller (FC4Gbit/s x 2ports) x1- Cache memory (1G) x1- Power Supply Unit x2

    At least two disk drives are mandatory. Up to 24 drives can be added.Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.

    2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.

    - Contents of Package

    Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)

    Rack mount kit 1 set

    Safety Precautions 1User Guide 1 CDRead me first 1

    - Additional Controller module (ETERNUS DX60 S2 Fibre Channel connection)

    Additional controller module for DX60 S2 (2.5inch, 4Gbps, FC)[Field] ETEEC6CF-L- Controller x1 (with FC 4Gbps 2port)- Cache memory (1GB x1)

    Additional controller module for DX60 S2 (3.5inch, 4Gbps, FC)[Field] ETEEC6DF-L- Controller x1 (with FC 4Gbps 2port)- Cache memory (1GB x1)

    (2) ETERNUS DX60 S2 (singl e-cont rol ler type)

    Product name ETERNUS DX60 S2

    (2.5inch, 4Gbps, FC, Single-controller)

    ETERNUS DX60 S2

    (3.5inch, 4Gbps, FC, Single-controller)Product ID ET062SCFU ET062SDFU

    Configuration

    Notes

    Components

    ETERNUS DX60 S2 (2.5")

    ETERNUS DX60 S2 (3.5")

    11

  • 7/24/2019 ETERNUS Configuration Guide

    13/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(2) ETERNUS DX60 S2 (singl e-cont rol ler type)

    ii) ETERNUS DX60 S2 base unit (Single controller type, SAS connection)

    Rackmount type (2U), AC200V modelEnclosure x1

    - Controller (SAS x 2ports) x1- Cache memory (1G) x1- Power Supply Unit x2

    At least two disk drives are mandatory. Up to 24 drives can be added.Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.

    - Contents of Package

    Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)

    Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1

    - Additional Controller module (ETERNUS DX60 S2 SAS connection)

    Additional controller module for DX60 S2 (2.5inch, 3Gbps, SAS)[Field] ETEEC6CS-L- Controller x1 (with SAS 3Gbps 2port)

    - Cache memory (1GB x1)

    Additional controller module for DX60 S2 (3.5inch, 3Gbps, SAS)

    [Field] ETEEC6DS-L- Controller x1 (with SAS 3Gbps 2port)- Cache memory (1GB x1)

    Notes

    Product name ETERNUS DX60 S2

    (2.5inch, 3Gbps, SAS, Single-

    ETERNUS DX60 S2

    (3.5inch, 3Gbps, SAS, Single-Product ID ET062SCSU ET062SDSU

    Configuration

    Components

    ETERNUS DX60 S2 (2.5")

    ETERNUS DX60 S2 (3.5")

    12

  • 7/24/2019 ETERNUS Configuration Guide

    14/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(2) ETERNUS DX60 S2 (singl e-cont rol ler type)

    iii) ETERNUS DX60 S2 Base Unit (Single controller type, iSCSI connection)

    Rackmount type (2U), AC200V model

    Enclosure x1- Controller (iSCSI x 2ports) x1- Cache memory (1G) x1- Power Supply Unit x2

    At least two disk drives are mandatory. Up to 24 drives can be added.Up to 24 drives can be installed in 2.5" type base unit.Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.

    2.5" Drive Enclosure cannot be added.One 3.5" Drive Enclosures can be added.

    - Contents of Package

    Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)

    Rack mount kit 1 set

    Safety Precautions 1User Guide 1 CDRead me first 1

    - Additional Controller module (ETERNUS DX60 S2 iSCSI connection)

    Additional controller module for DX60 S2 (2.5inch, 1Gbps, iSCSI)[Field] ETEEC6CL-L- Controller x1 (with iSCSI 1Gbps 2port)- Cache memory (1GB x1)

    Additional controller module for DX60 S2 (3.5inch, 1Gbps, iSCSI)[Field] ETEEC6DL-L- Controller x1 (with iSCSI 1Gbps 2port)- Cache memory (1GB x1)

    Components

    Product name ETERNUS DX60 S2

    (2.5inch, 1Gbps, iSCSI, Single-

    ETERNUS DX60 S2

    (3.5inch, 1Gbps, iSCSI, Single-Product ID ET062SCLU ET062SDLU

    Configuration

    Notes

    ETERNUS DX60 S2 (2.5")

    ETERNUS DX60 S2 (3.5")

    13

  • 7/24/2019 ETERNUS Configuration Guide

    15/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - ETERNUS DX80 S2 base unit (dual-controller type)

    Rackmount type (2U), AC200V modelEnclosure x1

    - Controller x2- Cache memory (2G) x2- Power Supply Unit x2

    - Two sets of Host Interfaces are mandatory.- Up to 24 drives can be installed in 2.5" type.

    Up to 12 drives can be installed in 3.5" type.- At least two disk drives are mandatory. Up to 120 drives can be added.- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

    - Contents of Package

    Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)Rack mount kit 1 setSafety Precautions 1User Guide 1 CD

    Read me first 1

    ET082DDUET082DCU

    (3) ETERNUS DX80 S2 (dual-controller type)

    ETERNUS DX80 S2

    (2.5inch, dual-controller type)

    ETERNUS DX80 S2

    (3.5inch, dual-controller type)

    Components

    Product ID

    Product name

    Notes

    Configuration

    14

  • 7/24/2019 ETERNUS Configuration Guide

    16/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(3) ETERNUS DX80 S2 (dual-controller type)

    - Host interface (ETERNUS DX80 S2)

    Two host interface options are mandatory. (Four host ports are mandatory.)Up to four options can be installed. (Up to eight ports can be installed.)Either two or four options should be same type. (Either four or eight ports should be same type.)

    Mixing different interfaces is supported.

    Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)

    [Factory] ETEHH12- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)[Field] ETEHH12-L

    - Host interface module (FC 16G) x1

    - SFP+ (16Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)

    [Factory] ETEHF12- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)

    [Field] ETEHF12-L- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Factory] ETEHS12- Host interface module (SAS) x1

    Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Field] ETEHS12-L

    - Host interface module (SAS) x1

    Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Factory] ETEHL12

    - Host interface module (iSCSI 1G) x1

    Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Field] ETEHL12-L

    - Host interface module (iSCSI 1G) x1

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Factory] ETEHY12- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Field] ETEHY12-L

    - Host interface module (iSCSI 10G) x1

    - SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Factory] ETEHY1N- Host interface module (iSCSI 10G) x1

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Field] ETEHY1N-L

    - Host interface module (iSCSI 10G) x1

    ETERNUS DX80 S2

    15

  • 7/24/2019 ETERNUS Configuration Guide

    17/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(3) ETERNUS DX80 S2 (dual-controller type)

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)

    [Factory] ETEHC12- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)[Field] ETEHC12-L

    - Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)[Factory] ETEHC1N- Host interface module (FCoE) x1

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)

    [Field] ETEHC1N-L- Host interface module (FCoE) x1

    [Factory]: Factory mount option

    [Field]: Field upgrade option

    16

  • 7/24/2019 ETERNUS Configuration Guide

    18/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - ETERNUS DX80 S2 base unit (single-controller type)

    Rackmount type (2U), AC200V modelEnclosure x1

    - Controller x1- Cache memory (2G) x1- Power Supply Unit x2

    - One Host Interface set is mandatory.No additional controller can be installed in the base unit of the single controllermodel at the time of shipment.

    - Up to 24 drives can be installed in 2.5" type.Up to 12 drives can be installed in 3.5" type.

    - At least two disk drives are mandatory. Up to 120 drives can be added.- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

    - Contents of Package Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)

    Rack mount kit 1 set

    Safety Precautions 1User Guide 1 CDRead me first 1

    '- Additional Controller module (ETERNUS DX80 S2)

    One Controller module can be added on single-controller type.

    Additional controller module for DX80 S2[Field] ETEAC8A-L

    - Controller x1- Cache memory (2GB x1)

    Notes

    Components

    Configuration

    (4) ETERNUS DX80 S2 (Single-controller type)

    Product name ETERNUS DX80 S2

    (2.5inch, single-controller type)

    ETERNUS DX80 S2

    (3.5inch, single-controller type)Product ID ET082SCU ET082SDU

    ETERNUS DX80 S2

    17

  • 7/24/2019 ETERNUS Configuration Guide

    19/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(4) ETERNUS DX80 S2 (Single-controller type)

    - Host interface (ETERNUS DX80 S2)

    One host interface option is mandatory. (Two host ports are mandatory.)Up to two options can be installed for single CM model. (Up to four ports can be installed.)Mixing different interfaces is supported for single CM model.

    Up to four options can be installed for dual CM model. (Up to eight ports can be installed.)Either two or four options should be same type for dual CM model.(Either four or eight ports should be same type for dual CM model.)

    Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)[Factory] ETEHH12- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)

    [Field] ETEHH12-L- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)[Factory] ETEHF12- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)[Field] ETEHF12-L

    - Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (SAS, 2port)

    [Factory] ETEHS12

    - Host interface module (SAS) x1

    Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Field] ETEHS12-L

    - Host interface module (SAS) x1

    Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Factory] ETEHL12- Host interface module (iSCSI 1G) x1

    Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Field] ETEHL12-L

    - Host interface module (iSCSI 1G) x1

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Factory] ETEHY12- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)

    [Field] ETEHY12-L- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)

    [Factory] ETEHY1N- Host interface module (iSCSI 10G) x1

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Field] ETEHY1N-L

    - Host interface module (iSCSI 10G) x1

    ETERNUS DX80 S2

    18

  • 7/24/2019 ETERNUS Configuration Guide

    20/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(4) ETERNUS DX80 S2 (Single-controller type)

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)

    [Factory] ETEHC12- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)[Field] ETEHC12-L

    - Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)[Factory] ETEHC1N- Host interface module (FCoE) x1

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)

    [Field] ETEHC1N-L- Host interface module (FCoE) x1

    [Factory]: Factory mount option

    [Field]: Field upgrade option

    19

  • 7/24/2019 ETERNUS Configuration Guide

    21/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - ETERNUS DX90 S2 base unit (dual-controller type)

    Rackmount type (2U), AC200VEnclosure x1

    - Controller x2

    - Cache memory (4GB) x2- Power Supply Unit x2

    - Two sets of the same Host Interface are mandatory.Up to 24 drives can be installed in 2.5" type.

    Up to 12 drives can be installed in 3.5" type.- At least two disk drives are mandatory. Up to 240 2.5" drives can be added.

    Up to 120 3.5" drives can be added.- Up to nine Drive Enclosures(2.5"/3.5") can be added.

    - Contents of Package

    Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1

    (5) ETERNUS DX90 S2 (dual-controller type)

    ETERNUS DX90 S2

    (2.5inch, dual-controller type)

    ETERNUS DX90 S2

    (3.5inch, dual-controller type)ET092DCU ET092DDU

    Components

    Product name

    Product ID

    Configuration

    Notes

    20

  • 7/24/2019 ETERNUS Configuration Guide

    22/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(5) ETERNUS DX90 S2 (dual-controller type)

    - Host interface (ETERNUS DX90 S2)

    Two host ports are mandatory. (Four ports host interface are mandatory.)Up to four options can be installed. (Up to eight ports can be installed.)Either two or four options should be same type. (Either four or eight ports should be same type.)

    Mixing different interfaces is supported.

    Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)

    [Factory] ETEHH12- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)[Field] ETEHH12-L

    - Host interface module (FC 16G) x1

    - SFP+ (16Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)

    [Factory] ETEHF12- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)

    [Field] ETEHF12-L- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Factory] ETEHS12- Host interface module (SAS) x1

    Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Field] ETEHS12-L

    - Host interface module (SAS) x1

    Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Factory] ETEHL12

    - Host interface module (iSCSI 1G) x1

    Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Field] ETEHL12-L

    - Host interface module (iSCSI 1G) x1

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Factory] ETEHY12- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Field] ETEHY12-L

    - Host interface module (iSCSI 10G) x1

    - SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Factory] ETEHY1N- Host interface module (iSCSI 10G) x1

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Field] ETEHY1N-L

    - Host interface module (iSCSI 10G) x1

    ETERNUS DX90 S2

    21

  • 7/24/2019 ETERNUS Configuration Guide

    23/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(5) ETERNUS DX90 S2 (dual-controller type)

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)

    [Factory] ETEHC12- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)[Field] ETEHC12-L

    - Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)[Factory] ETEHC1N- Host interface module (FCoE) x1

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)

    [Field] ETEHC1N-L- Host interface module (FCoE) x1

    [Factory]: Factory mount option

    [Field]: Field upgrade option

    22

  • 7/24/2019 ETERNUS Configuration Guide

    24/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - ETERNUS DX90 S2 base unit (single-controller type)

    Rackmount type (2U), AC200VEnclosure x1

    - Controller x1

    - Cache memory (4GB) x1- Power Supply Unit x2

    - One set of the same Host Interfaces are mandatory.No additional controller can be installed in the base unit of the single controller

    model at the time of shipment.- Up to 24 drives can be installed in 2.5" type.

    Up to 12 drives can be installed in 3.5" type.- At least two disk drives are mandatory. Up to 240 2.5" drives can be added.

    Up to 120 3.5" drives can be added.- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

    - Contents of Package Quantity Note

    AC200V power cord 2 4m (NEMA L6-15P)

    Rack mount kit 1 setSafety Precautions 1User Guide 1 CDRead me first 1

    - Additional Controller module (ETERNUS DX90 S2)

    One Controller module can be added on single-controller type.

    Additional controller module for DX90 S2[Field] ETEAC9A-L

    - Controller x1

    - Cache memory (4GB x1)

    (6) ETERNUS DX90 S2 (si ngle-cont rol ler type)

    Product name ETERNUS DX90 S2

    (2.5inch, single-controller type)

    ETERNUS DX90 S2

    (3.5inch, single-controller type)Product ID ET092SCU ET092SDU

    Configuration

    Notes

    Components

    ETERNUS DX90 S2

    23

  • 7/24/2019 ETERNUS Configuration Guide

    25/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(6) ETERNUS DX90 S2 (si ngle-cont rol ler type)

    - Host interface (ETERNUS DX90 S2)

    One host interface option is mandatory. (Two host ports are mandatory.)Up to two options can be installed for single CM model. (Up to four ports can be installed.)Mixing different interfaces is supported for single CM model.

    Up to four options can be installed for dual CM model. (Up to eight ports can be installed.)Either two or four options should be same type for dual CM model.(Either four or eight ports should be same type for dual CM model.)

    Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)[Factory] ETEHH12- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)

    [Field] ETEHH12-L- Host interface module (FC 16G) x1- SFP+ (16Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)[Factory] ETEHF12- Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)[Field] ETEHF12-L

    - Host interface module (FC 8G) x1- SFP+ (8Gbit/s) module x2

    Host interface for DX80 S2/DX90 S2 (SAS, 2port)

    [Factory] ETEHS12

    - Host interface module (SAS) x1

    Host interface for DX80 S2/DX90 S2 (SAS, 2port)[Field] ETEHS12-L

    - Host interface module (SAS) x1

    Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Factory] ETEHL12- Host interface module (iSCSI 1G) x1

    Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)[Field] ETEHL12-L

    - Host interface module (iSCSI 1G) x1

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)[Factory] ETEHY12- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)

    [Field] ETEHY12-L- Host interface module (iSCSI 10G) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)

    [Factory] ETEHY1N- Host interface module (iSCSI 10G) x1

    Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)[Field] ETEHY1N-L

    - Host interface module (iSCSI 10G) x1

    ETERNUS DX90 S2

    24

  • 7/24/2019 ETERNUS Configuration Guide

    26/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(6) ETERNUS DX90 S2 (si ngle-cont rol ler type)

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)

    [Factory] ETEHC12- Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)[Field] ETEHC12-L

    - Host interface module (FCoE) x1- SFP+ (10Gbit/s) x2

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)[Factory] ETEHC1N- Host interface module (FCoE) x1

    Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)

    [Field] ETEHC1N-L- Host interface module (FCoE) x1

    [Factory]: Factory mount option

    [Field]: Field upgrade option

    25

  • 7/24/2019 ETERNUS Configuration Guide

    27/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - Disk drive option (2.5inch disk drive)* 2.5inch drives are installed in the 2.5inch type controller enclosure

    Disk drive

    * Mandatory option

    * Up to 24 drives can be installed in a 2.5inch base unit.2.5inch 10krpm SAS disk drive

    Factory mount options

    Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX60 S2 ETED3MBDisk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX60 S2 ETED3PBDisk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX60 S2 ETED3DBDisk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX60 S2 ETED3SB

    Disk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2 ETED3HB

    Disk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX60 S2 ETED4MBDisk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX60 S2 ETED4PBDisk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX60 S2 ETED4DBDisk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX60 S2 ETED4SBDisk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2 ETED4HBDisk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX60 S2 ETED6MB

    Disk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX60 S2 ETED6PBDisk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX60 S2 ETED6DBDisk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX60 S2 ETED6SBDisk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2 ETED6HBDisk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX60 S2 ETED9MBDisk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX60 S2 ETED9PBDisk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX60 S2 ETED9DB

    Disk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX60 S2 ETED9SBDisk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2 ETED9HBField upgrade optionsDisk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2 ETED3HB-LDisk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2 ETED4HB-LDisk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2 ETED6HB-LDisk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2 ETED9HB-L

    2.5inch 7.2krpm SAS disk drive

    Factory mount options

    Disk Drive(2.5inch) 1TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN1MB

    Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN1PBDisk Drive(2.5inch) 1TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN1DB

    Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN1SBDisk Drive(2.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HBField upgrade optionsDisk Drive(2.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HB-L

    #1 Two or more disk drives are mandatory for one base unit.#2 Install hot spare disks for stable operation.#3 A mixture of different size disk drives is supported.

    The capacity of the hot spare disk should match the capacity of the largest disk drive.Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,

    600GB/10krpm SAS disk x6 (RAID5) x1

    => 600GB disk drive x1 is the hot spare.#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives

    (same capacity, rotation speed and interface speed) are required.

    (7) Options

    2.5inch disk drive

    Product name

    Product name

    Product ID

    Product ID

    ETERNUS DX60 S2

    26

  • 7/24/2019 ETERNUS Configuration Guide

    28/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    - Disk drive option (3.5inch disk drive)

    Disk drive

    * Mandatory option* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.

    Factory mount options

    Disk Drive(3.5inch) 300GB 15krpm x1 for DX60 S2 ETED3HADisk Drive(3.5inch) 300GB 15krpm x6 (RAID5) for DX60 S2 ETED3PADisk Drive(3.5inch) 300GB 15krpm x6 (RAID6) for DX60 S2 ETED3DADisk Drive(3.5inch) 300GB 15krpm x6 (RAID1+0) for DX60 S2 ETED3SA

    Disk Drive(3.5inch) 300GB 15krpm x2 (RAID1) for DX60 S2 ETED3MADisk Drive(3.5inch) 450GB 15krpm x2 (RAID1) for DX60 S2 ETED4MADisk Drive(3.5inch) 450GB 15krpm x6 (RAID5)for DX60 S2 ETED4PA

    Disk Drive(3.5inch) 450GB 15krpm x6 (RAID6) for DX60 S2 ETED4DADisk Drive(3.5inch) 450GB 15krpm x6 (RAID1+0) for DX60 S2 ETED4SADisk Drive(3.5inch) 450GB 15krpm x1 for DX60 S2 ETED4HADisk Drive(3.5inch) 600GB 15krpm x2 (RAID1) for DX60 S2 ETED6MADisk Drive(3.5inch) 600GB 15krpm x6 (RAID5) for DX60 S2 ETED6PA

    Disk Drive(3.5inch) 600GB 15krpm x6 (RAID6) for DX60 S2 ETED6DADisk Drive(3.5inch) 600GB 15krpm x6 (RAID1+0) for DX60 S2 ETED6SADisk Drive(3.5inch) 600GB 15krpm x1 for DX60 S2 ETED6HADisk Drive(3.5inch) 1TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN1MADisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN1PADisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN1DADisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN1SA

    Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HA

    Disk Drive(3.5inch) 2TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN2MADisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN2PADisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN2DADisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN2SADisk Drive(3.5inch) 2TB 7.2krpm x1 for DX60 S2 ETEN2HADisk Drive(3.5inch) 3TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN3MA

    Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN3PADisk Drive(3.5inch) 3TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN3DADisk Drive(3.5inch) 3TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN3SADisk Drive(3.5inch) 3TB 7.2krpm x1 for DX60 S2 ETEN3HAField upgrade optionsDisk Drive(3.5inch) 300GB 15krpm x1 for DX60 S2 ETED3HA-L

    Disk Drive(3.5inch) 450GB 15krpm x1 for DX60 S2 ETED4HA-LDisk Drive(3.5inch) 600GB 15krpm x1 for DX60 S2 ETED6HA-LDisk Drive(3.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HA-LDisk Drive(3.5inch) 2TB 7.2krpm x1 for DX60 S2 ETEN2HA-LDisk Drive(3.5inch) 3TB 7.2krpm x1 for DX60 S2 ETEN3HA-L

    #1 Two or more disk drives are mandatory for one base unit.#2 Install hot spare disks for stable operation.

    #3 A mixture of different capacity disk drives is supported.When installing different capacity disk drives in one base unit,the capacity of the hot spare disk should match the capacity of the largest disk drive.

    Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1=> 600GB disk drive x1 is the hot spare.

    #4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.When installing different type disk drives in one base unit,it is recommended that at least one hot spare disk of each type be installed.

    #5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives(same capacity, rotation speed and interface speed) are required.

    3.5inch disk drive

    Product name Product ID

    ETERNUS DX60 S2

    27

  • 7/24/2019 ETERNUS Configuration Guide

    29/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    - Drive enclosure (3.5inch)

    Dual-IOM type supports dual controller model only.

    Drive enclosure for DX60 S2 (3.5inch, dual-expander type)[Factory] ETEED2DU

    [Field] ETEED2DU-L- Rack mount type (2U)- Enclosure [Expander (SAS 1port) x2, PSU x2] x1- Up to 12 disk drives can be installed in one drive enclosure.- Attachment list

    Qty

    Rackmount kit 1 set

    AC200V power cable 2 4m (NEMA L6-15P)

    SAS cable 2 75cm: Bace unit Drive enclosure connection

    Disk driveRefer "Disk drive option (3.5inch)"* Up to 12 disk drives can be installed.

    Drive enclosure for DX60 S2 (3.5inch, single-expander type)[Factory] ETEED1DU

    [Field] ETEED1DU-L- Rack mount type (2U)- Enclosure [Expander (SAS 1port) x1, PSU x2] x1

    - Up to 12 disk drives can be installed in one drive enclosure.- Attachment list

    Qty

    Rackmount kit 1 set

    AC200V power cable 2 4m (NEMA L6-15P)SAS cable 1 75cm: Bace unit

    Drive enclosure connection

    Additional expander for DX60 S2 (3.5inch)[Field] ETEEXD-L

    - Attachment list

    Qty

    IOM 1

    SAS cable 1 75cm: Bace unit Drive enclosure connection

    Disk driveRefer "Disk drive option (3.5inch)"* Up to 12 disk drives can be installed.

    - Extension cable

    - The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)supplied with the drive enclosures are too short to connect.

    Extension cable between enclosures for DX60 S2 (3m)[Field] ETEC1M3-L

    - 1x mini SAS cable 3m

    Attachment Notes

    Attachment Notes

    Attachment Notes

    ETERNUS DX60 S2

    ETERNUS DX60 S2

    28

  • 7/24/2019 ETERNUS Configuration Guide

    30/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    - Disk drive option (2.5inch disk drive)* 2.5inch drives are installed in the 2.5inch type controller enclosure and drive enclosures.

    Disk drive

    * Mandatory option

    * Up to 24 drives can be installed in a 2.5inch base unit or a 2.5inch drive enclosure.

    2.5inch 10krpm SAS disk drive

    Factory mount options

    Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MCDisk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PCDisk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DC

    Disk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SC

    Disk Drive(2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HCDisk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4MCDisk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PCDisk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DCDisk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SCDisk Drive(2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HC

    Disk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6MCDisk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PCDisk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DCDisk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SCDisk Drive(2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HCDisk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED9MCDisk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED9PC

    Disk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED9DCDisk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED9SCDisk Drive(2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HCField upgrade optionsDisk Drive(2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HC-LDisk Drive(2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HC-LDisk Drive(2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HC-L

    Disk Drive(2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HC-L

    2.5inch 15krpm SAS disk drive

    Factory mount options

    Disk Drive (2.5inch) 300GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MGDisk Drive (2.5inch) 300GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PG

    Disk Drive (2.5inch) 300GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DGDisk Drive (2.5inch) 300GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SGDisk Drive (2.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HGField upgrade optionsDisk Drive (2.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HG-L

    2.5inch 7.2krpm SAS disk drive

    Factory mount options

    Disk Drive (2.5inch) 1TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN1MCDisk Drive (2.5inch) 1TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN1PC

    Disk Drive (2.5inch) 1TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN1DCDisk Drive (2.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN1SCDisk Drive (2.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HCField upgrade options

    Disk Drive (2.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HC-L

    2.5inch disk drive

    Product name Product ID

    Product IDProduct name

    Product name Product ID

    ETERNUS DX80 S2, DX90

    29

  • 7/24/2019 ETERNUS Configuration Guide

    31/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    Self Encrypting Disk Drive, 2.5inch 10krpm SAS disk drive

    Factory mount options

    Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MESelf Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PESelf Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DESelf Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SE

    Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4MESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SESelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HESelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6MESelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PE

    Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DESelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SESelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HESelf Encrypting Disk Drive (2.5inch) 900GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED9ME

    Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED9PESelf Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED9DESelf Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED9SE

    Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HEField upgrade optionsSelf Encrypting Disk Drive (2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HE-LSelf Encrypting Disk Drive (2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HE-LSelf Encrypting Disk Drive (2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HE-LSelf Encrypting Disk Drive (2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HE-L

    #1 Two or more disk drives are mandatory for one base unit.

    #2 Install hot spare disks for stable operation.#3 A mixture of different size disk drives is supported.

    The capacity of the hot spare disk should match the capacity of the largest disk drive.Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,

    600GB/10krpm SAS disk x6 (RAID5) x1=> 600GB disk drive x1 is the hot spare.

    #4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives(same capacity, rotation speed and interface speed) are required.

    Product IDProduct name

    30

  • 7/24/2019 ETERNUS Configuration Guide

    32/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    '- Disk drive option (3.5inch disk drive)

    Disk drive

    * Mandatory option* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.

    Factory mount options

    Disk Drive(3.5inch) 300GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MDDisk Drive(3.5inch) 300GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PDDisk Drive(3.5inch) 300GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DDDisk Drive(3.5inch) 300GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SD

    Disk Drive(3.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HDDisk Drive(3.5inch) 450GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4MDDisk Drive(3.5inch) 450GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PD

    Disk Drive(3.5inch) 450GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DDDisk Drive(3.5inch) 450GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SDDisk Drive(3.5inch) 450GB 15krpm x1 for DX80 S2/DX90 S2 ETED4HDDisk Drive(3.5inch) 600GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6MDDisk Drive(3.5inch) 600GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PD

    Disk Drive(3.5inch) 600GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DDDisk Drive(3.5inch) 600GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SDDisk Drive(3.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HDDisk Drive(3.5inch) 1TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN1MDDisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN1PDDisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN1DDDisk Drive(3.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN1SD

    Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HD

    Disk Drive(3.5inch) 2TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN2MDDisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN2PDDisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN2DDDisk Drive(3.5inch) 2TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN2SDDisk Drive(3.5inch) 2TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN2HDDisk Drive(3.5inch) 3TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN3MD

    Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN3PDDisk Drive(3.5inch) 3TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN3DDDisk Drive(3.5inch) 3TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN3SDDisk Drive(3.5inch) 3TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN3HDField upgrade optionsDisk Drive(3.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HD-L

    Disk Drive(3.5inch) 450GB 15krpm x1 for DX80 S2/DX90 S2 ETED4HD-LDisk Drive(3.5inch) 600GB 15krpm x1 for DX80 S2/DX90 S2 ETED6HD-LDisk Drive(3.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HD-LDisk Drive(3.5inch) 2TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN2HD-LDisk Drive(3.5inch) 3TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN3HD-L

    #1 Two or more disk drives are mandatory for one base unit.#2 Install hot spare disks for stable operation.

    #3 A mixture of different capacity disk drives is supported.When installing different capacity disk drives in one base unit,the capacity of the hot spare disk should match the capacity of the largest disk drive.

    Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1=> 600GB disk drive x1 is the hot spare.

    #4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.When installing different type disk drives in one base unit,it is recommended that at least one hot spare disk of each type be installed.

    #5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives(same capacity, rotation speed and interface speed) are required.

    Product name Product ID

    3.5inch disk drive

    ETERNUS DX80 S2, DX90

    31

  • 7/24/2019 ETERNUS Configuration Guide

    33/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    - SSD

    SSD2.5inch disk drives

    Factory mount options

    SSD(2.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2 ETES1MC

    SSD(2.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2 ETES1PCSSD(2.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES1SC

    SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HC

    SSD(2.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2 ETES2MCSSD(2.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2 ETES2PCSSD(2.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES2SCSSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HCSSD(2.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2 ETES4MC

    SSD(2.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2 ETES4PCSSD(2.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES4SC

    SSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HCSSD(2.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2 ETES8MCSSD(2.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2 ETES8PCSSD(2.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES8SCSSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HC

    Field upgrade options

    SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HC-L

    SSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HC-LSSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HC-LSSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HC-L

    SSD3.5inch disk drives

    Factory mount optionsSSD(3.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2 ETES1MDSSD(3.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2 ETES1PDSSD(3.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES1SDSSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HDSSD(3.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2 ETES2MDSSD(3.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2 ETES2PD

    SSD(3.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES2SDSSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HDSSD(3.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2 ETES4MDSSD(3.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2 ETES4PDSSD(3.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES4SD

    SSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HDSSD(3.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2 ETES8MD

    SSD(3.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2 ETES8PDSSD(3.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES8SDSSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HDField upgrade optionsSSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HD-LSSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HD-LSSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HD-LSSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HD-L

    * SSD supports RAID1, RAID1+0 and RAID5 only.

    Product IDProduct name

    ETERNUS DX80 S2, DX90

    32

  • 7/24/2019 ETERNUS Configuration Guide

    34/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    - Drive enclosure (2.5inch)

    Dual-IOM type supports dual controller model only.

    Drive enclosure for DX80 S2/DX90 S2 (2.5inch, dual-IOM type)

    [Factory] ETEAD2CU[Field] ETEAD2CU-L

    - Rack mount type (2U)- Enclosure [IOM (SAS 1port) x2, PSU x2] x1- Up to 24 disk drives can be installed in one drive enclosure.- Attachment list

    Qty

    Rackmount kit 1 set

    AC200V power cable 2 4m (NEMA L6-15P)SAS cable 2 75cm: Bace unit

    Drive enclosure connectionDisk driveRefer "Disk drive option (2.5inch)"* Up to 24 disk drives can be installed.

    Drive enclosure for DX80 S2/DX90 S2 (2.5inch, single-IOM type)

    [Factory] ETEAD1CU[Field] ETEAD1CU-L

    - Rack mount type (2U)- Enclosure [IOM (SAS 1port) x1, PSU x2] x1- Up to 24 disk drives can be installed in one drive enclosure.- Attachment list

    Qty

    Rackmount kit 1 set

    AC200V power cable 2 4m (NEMA L6-15P)SAS cable 1 75cm: Bace unit

    Drive enclosure connection

    Additional IOM for DX80 S2/DX90 S2

    [Field] ETEAMA-L- Attachment list

    Qty

    IOM 1

    SAS cable 1 75cm: Bace unit Drive enclosure connection

    Disk drive

    Refer "Disk drive option (2.5inch)"* Up to 24 disk drives can be installed.

    NotesAttachment

    Attachment Notes

    Attachment Notes

    ETERNUS DX80 S2, DX90 S2

    33

  • 7/24/2019 ETERNUS Configuration Guide

    35/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    - Drive enclosure (3.5inch)

    Dual-IOM type supports dual controller model only.

    Drive enclosure for DX80 S2/DX90 S2 (3.5inch, dual-IOM type)[Factory] ETEAD2DU

    [Field] ETEAD2DU-L- Rack mount type (2U)- Enclosure [IOM (SAS 1port) x2, PSU x2] x1- Up to 12 disk drives can be installed in one drive enclosure.- Attachment list

    Qty

    Rackmount kit 1 set

    AC200V power cable 2 4m (NEMA L6-15P)

    SAS cable 2 75cm: Bace unit Drive enclosure connectionDisk drive

    Refer "Disk drive option (3.5inch)"* Up to 12 disk drives can be installed.

    Drive enclosure for DX80 S2/DX90 S2 (3.5inch, single-IOM type)[Factory] ETEAD1DU

    [Field] ETEAD1DU-L- Rack mount type (2U)- Enclosure [IOM (SAS 1port) x1, PSU x2] x1- Up to 12 disk drives can be installed in one drive enclosure.

    - Attachment list

    Qty

    Rackmount kit 1 set

    AC200V power cable 2 4m (NEMA L6-15P)SAS cable 2 75cm: Bace unit Drive enclosure connection

    Additional IOM for DX80 S2/DX90 S2[Field] ETEAMA-L

    - Attachment list

    Qty

    Rackmount kit 1 set

    SAS cable 2 75cm: Bace unit Drive enclosure connection

    Disk driveRefer "Disk drive option (3.5inch)"* Up to 12 disk drives can be installed.

    - Extension cable

    - The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)supplied with the drive enclosures are too short to connect.

    Extension cable between enclosures for DX80 S2/DX90 S2 (3m)[Field] ETEC1Q3-L- QSFP cable (3m) x1

    Extension cable between enclosures for DX80 S2/DX90 S2 (6m)[Field] ETEC1Q6-L

    - QSFP cable (6m) x1

    Notes

    Attachment

    Attachment

    Notes

    Attachment Notes

    ETERNUS DX80 S2, DX90 S2

    ETERNUS DX80 S2, DX90 S2

    34

  • 7/24/2019 ETERNUS Configuration Guide

    36/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - Thin Provisioni ng Feature

    Single controller model does not support Thin Provisioning Feature.

    Thin Provisioning Feature License for DX80 S2[Factory] ETEL8T[Field] ETEL8T-L

    - License label x1- To use Thin provisioning Feature, one license is required per one unit.

    Thin Provisioning Feature License for DX90 S2[Factory] ETEL9T

    [Field] ETEL9T-L- License label x1- To use Thin provisioning Feature, one license is required per one unit.

    [Factory]: Factory mount option[Field]: Field upgrade option

    (7) Options

    ETERNUS DX80 S2

    ETERNUS DX90 S2

    35

  • 7/24/2019 ETERNUS Configuration Guide

    37/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - Outlet box

    - Power distribution unit

    Power distribution unit for DX60 S2/DX80 S2/DX90 S2(AC200-240V, 1U Max 2 enclosures connection)ETEP4BU-LRack mount type (1U), AC200VThere are up to two options for connecting a base unit anddrive enclosure.

    (PDU for Base unit x2 or PDU for Drive enclosure x2 orPDU for Base unit x1 + PDU for Drive enclosure x1)

    - Power distribution unit (AC200V)1- Input AC cable (NEMA L6-15P, 3m) x2

    - Output AC cable (3m) x4, Rack mount kit x1

    NEMA L6-15 outlet

    Power distribution unit for DX60 S2/DX80 S2/DX90 S2(AC200-240V, 2U, Max 6 enclosures connection)

    ETEP12U-LRack mount type (1U), AC200VUp to six base units or drive enclosures can be connected.

    (Base unit x6,Base unit x2 + Drive enclosure x4Base unit x1 + Drive enclosure x5, etc.)

    - Power distribution unit (AC200V)1

    - Input AC cable (NEMA L6-20P, 4m) x2

    - Output AC cable (3m) x12, Rackmount kit x1

    NEMA L6-20 outlet

    Power distribution unit for DX60 S2/DX80 S2/DX90 S2(AC200-240V, 2U, Max 8 enclosures connection)

    ETEP16U-LRack mount type (1U), AC200VUp to eight base units or drive enclosures can be connected.

    (Base unit x8,

    Base unit x2 + Drive enclosure x6Base unit x1 + Drive enclosure x7, etc.)- Power distribution unit (AC200V)1- Input AC cable (NEMA L6-30P, 4m) x2- Output AC cable (3m) x16, Rackmount kit x1

    NEMA L6-30 outlet

    (7) Options

    ETERNUS DX60 S2, DX80 S2, DX90

    36

  • 7/24/2019 ETERNUS Configuration Guide

    38/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2(7) Options

    - IEC Power cableAC cable (IEC60320 C13 - IEC60320 C14)

    ST-PWG13- To connect IEC 320-C14 components,

    one option is required per one base unit or drive enclosure.- AC200V cable (IEC320 C14, 3m) x2

    200V (Standard) IEC320

    NEMA L6-15 outlet IEC320 outlet

    ETERNUS DX60 S2, DX80 S2, DX90

    37

  • 7/24/2019 ETERNUS Configuration Guide

    39/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    Power Synchronized UnitST-PSM20U

    - Power Synchronized Unit x1- RS232C cable x2- Parts kit for 19-inch rack

    AC Sensor Unit (AC200V)ST-PSL20SU- AC Sensor Unit x1- RCI cable (4m) x1

    - RCI brunch connector x1- Parts kit for 19-inch rack

    Note that power cords (for AC power input) for power synchronized units and power cords (for AC sensor) to connect

    server UPS units to power synchronized units or AC sensor units are not supplied with power synchronized units.

    The IEC 60320-C14 port type is used for the AC IN ports and the SENSOR ports of the power synchronized units.

    This port type is also used for the AC IN ports of the AC sensor units.Check the specifications of the power sockets and server UPS unit outlets that are to be used for the powersynchronized units and AC sensor units. Prepare the required number of appropriate power cords.

    Power cord (for AC power input)- Each Power Synchronized Unit requires one Power cord.- The voltage for the AC IN port is 10A 250V or less.

    Power cord (for AC sensor)

    - Each server UPS Unit that is to be connected to The Power Synchronized Unit requires one Power cord.- Each AC sensor Unit requires one Power cord.

    Be sure that the power cords have the approval of the appropriate safety agencies of the country where the equipmentwill be used.

    (7) Options

    ETERNUS DX60 S2, DX80 S2, DX90

    38

  • 7/24/2019 ETERNUS Configuration Guide

    40/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - Fibre channel cable (Fibre channel, 10Gbits/s iSCSI, FCoE connection)

    Fibre channel cableLength

    CBL-MLLC05 5m LC-LC

    CBL-MLLC10 10mCBL-MLLC20 20mCBL-MLLC30 30mCBL-MLLC40 40mCBL-MLLC50 50mCBL-MLLD1A 100mCBL-MLLB02 * 2mCBL-MLLB05 * 5m

    - m

    * For connection between same rack.Fibre channel card, Fibre channel switch

    - SAS cable (SAS connection)

    SAS cable

    LengthCBL-SASB1U 1.5m - SAS connectionCBL-SASB3U 3m

    CBL-SASB6U 6m

    SAS card

    - Twinax Cable (10 Gbit/s iSCSI withtout SFP+, FCoE without SFP+ connection)

    Twinax cable

    TypeEBRTWX11 1m Brocade/10G-SFPP-TWX-0101EBRTWX31 3m Brocade/10G-SFPP-TWX-0301EBRTWX51 5m Brocade/10G-SFPP-TWX-0501S26361-F4571-L10 7m Cisco/SFP-H10GB-ACU7M

    S26361-F4571-L11 10m Cisco/SFP-H10GB-ACU10M

    S26361-F3989-L10 5m Fujitsu/T26139-Y4006-M5

    FCoE, iSCSI card

    Product ID Notes

    Notes

    (8) Cables

    Product ID

    Product ID Notes

    With cover

    Without cover

    ETERNUS DX60 S2ETERNUS DX80 S2ETERNUS DX90 S2

    ETERNUS DX60 S2ETERNUS DX80 S2ETERNUS DX90 S2

    ETERNUS DX80 S2

    ETERNUS DX90 S2

    39

  • 7/24/2019 ETERNUS Configuration Guide

    41/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    - Rack for ETERNUS DX60 S2, DX80 S2, DX90 S2

    ETERNUS DX80 S2, DX90 S2 can be installed in the following racks.

    Base Rack Expansion Rack19-inch Rack Model 2742 Standard 42U 19R-274A2 19R-274B219-inch Rack Model 2737 Standard 37U 19R-273A2 19R-273B2

    19-inch Rack Model 2724 Standard 24U 19R-272A2 -19-inch Rack Model 2642 Slim 42U 19R-264A2 19R-264B219-inch Rack Model 2624 Slim 24U 19R-262A2 -19-inch Rack Model 2616 Slim 16U 19R-261A2 -19-inch rack without stabilizers 40U ETNRKC2U ETNRKD2U19-inch rack with stabilizers 40U ETNRKC1U ETNRKD1U

    - Notes

    - Height and rack installation order are as follows.

    ETEAD2CU, ETEAD2CU-LETEAD2DU, ETEAD2DU-L

    ETERNUS DX80 S2 base unit ET082DCU, ET082DDUETERNUS DX90 S2 base unit ET092DCU, ET092DDU

    ETEP4BU-L 1UETEP12U-L

    ETEP16U-L

    2

    HeightProduct name Install order for the

    rack

    1

    Drive enclosure 3

    Power distribution unit (AC200V)2U

    2U

    (9) Rack

    Product ID

    Product name Height Product ID

    40

  • 7/24/2019 ETERNUS Configuration Guide

    42/42

    ETERNUS DX60 S2, DX80 S2, DX90 S2

    B025C1020H

    B025C1120H

    B025C1220H

    B011103H0H

    B0214G2H0HB013162H0HAIX

    ETERNUS Multipath Driver V2 (Linux 32bit/64bit)

    AIX ETERNUS Multipath Driver 2

    Product ID Product name

    Windows ETERNUS Multipath Driver for Entry Model V2.x

    Windows ETERNUS Multipath Driver for Standard Model V2.x

    Windows ETERNUS Multipath Driver for Enterprise Model V2.x

    Solaris ETERNUS Multipath Driver 3.x

    (10) ETERNUS Multipath Driver

    OS

    Windows

    Solaris

    Linux