ess geos 5508 embed straingauge rt em

Upload: anthony-fu

Post on 03-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/12/2019 Ess Geos 5508 Embed Straingauge Rt Em

    1/2

    Long-term reliability

    High resolution and

    accuracy

    Adjustable 3000 mi-

    crostrain range

    Very high compliance

    Rugged construction

    Temperature reading Flanges fitted with

    mounting holes

    Frequency signal

    easy to process andtransmit over longdistances

    The EM Series of VibratingWire Strain Gauges are de-signed for concrete embed-ment in order to measurestrains caused by stressvariations. The stress canalso be evaluated when theconcrete's modulus of elas-ticity is known, followingcompensation for tempera-ture, creeping and concretereaction effects. The EM isembedded in structuressuch as:

    Dams

    Nuclear power plants

    Bridges and overpasses

    Tall buildings

    Tunnels

    Harbours

    Foundations, walls, lin-

    ings, footings, and piles

    The EM is composed of two endpieces joined by a tube that pro-tects a length of steel wire. Thewire is sealed in the tube by aset of O rings on each endpiece. Both end pieces have a

    flat circular flange to allow trans-fer of concrete deformation tothe wire. An electromagnet is fit-ting at the centre of the gauge.Strain developing in the con-crete modifies the tension in thewire and its resonant frequency,which is read by the electromag-net.

    The EM-5 is the standard modeland is used in different types ofstructures as mentioned above.

    The EM-l0 consists of a ruggedversion to be embedded in con-crete with coarse aggregates.

    The shorter EM-2 model is de-signed for laboratory use or forlimited spaces.

    Unless specified otherwise, thegauge tension is factory-adjusted at mid-range.

    The gauge is very compliant. Itdoes not induce stresses in the

    host media and can therefore be

    embedded in young curing con-crete as well as in hard, syn-thetic materials such as resins,fibreglass and urethane.

    A thermistor incorporated intothe EEM supplies informationon the effects of temperature

    on the materials.

    GEOSYSTEMS

    Geotechnical Instrumentation Design, Manufacture, Installation, Data Acquisition, On-Line Monitoring

    Embedded VW Strain GaugesModel 5508-RT-EM Series

    EmbeddedVWStrainGa

    ugesModel5508-RT

    -EM

    Series

    Description

    FEATURES

    Email: [email protected] Website: www.geosystems.com.au

    For Further Information Contact: Geosystems Australia Pty Ltd, 20 William Street East, LilydaleVICTORIA 3140, AUSTRALIA Tel: 61 3 9735 5255 Fax: 61 3 9735 5277

    APPLICATIONS

    environmental systems & services| 8 River Street, Richmond VIC 3121 Australia

    T + 61 3 8420 8999 | F + 61 3 8420 8900 | [email protected] | www.geosystems.com.au

    FOR FURTHER INFORMATION

  • 8/12/2019 Ess Geos 5508 Embed Straingauge Rt Em

    2/2

    EmbeddedVWStrainG

    augesModel5508-RT-EM

    Series

    For Further Information Contact: Geosystems Australia Pty Ltd, 20 William Street East, LilydaleVICTORIA 3140, AUSTRALIA Tel: 61 3 9735 5255 Fax: 61 3 9735 5277

    Email: [email protected] Website: www.geosystems.com.au

    There are several ways toinstall the gauge: Attaching it to a rebar with

    tie wire Inserting it directly into wet

    concrete or grout

    Pre-casting it in briquettewith the same mix for sub-sequent embedment

    A mounting rosette that al-lows gauges to be preciselyoriented is offered as an ac-cessory. Also offered is a"no-stress" strain gauge thatconsists of a compressiblecylinder filled with the con-crete mix from the mass be-ing poured.

    This unit, containing an EM,is placed adjacent to thegauge installation and isused as a reference to meas-ure any internal variation ofstrain in the concrete due toageing, temperature, humid-ity and factors independent ofexternal loads.

    Portable readout units

    (MB-6T(L), PAMETO VW)

    Data acquisition system

    (SENSLOG)

    Rosette mounting block

    "No-stress" strain gauge

    Terminal and junction

    boxes.

    Lightning protection box

    Splicing kit

    Type of thermistor and

    cable

    Installation

    Specifications

    Due to on-going design improvements and reviews, we reserve the right to amend product and specifications without prior notice

    Accessories

    Options

    Model: EM-2 EM-5 EM-10

    Strain Range: 3000

    Resolution: - Wire:- Temperature:

    0.4 1 (min.) 0.4

    Operating Temperature Range: -50C to +60C

    Thermistor: -Type:- Accuracy:

    3 kW (2 kW optional) 0.5% F.S.

    Electrical Cable: - IRC-41A (standard): 2 twisted shielded pairs 22AWG, 6.2 mm O.D., PVC jacket

    - IRC-41P (optional): identical to IRC-41A exceptthat jacket is polyethylene

    environmental systems & services| 8 River Street, Richmond VIC 3121 Australia

    T + 61 3 8420 8999 | F + 61 3 8420 8900 | [email protected] | www.geosystems.com.au