es series guide specifications - hydropump

29
Series ES Size Range ES025ES071 Size Available (Tons) 2, 3, 4, 5, 6 GLHP Efficiency EER 15.524.5 COP 3.64.0 GWHP Efficiency EER 19.030.0 COP 4.04.6 WLHP Efficiency EER 13.517.5 COP 4.45.4 Stages 2 Stage Configuration VT, HZ, CF Compressor Ultra Tech Blower ECM Auxiliary Heat Internal Hot Gas ReHeat Optional Hot Gas ByPass Optional Evaporator Coil Uncoated, Tinplated Desuperheater Optional Compressor Noise Reduction Standard Stainless Steel Drain Pan Standard Energy Star Qualified Closed Loop: ES025ES061 (VT, HZ, CF) Open Loop: ES025ES071 (VT, HZ, CF) ES Series Guide Specifications

Upload: others

Post on 30-Apr-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ES Series Guide Specifications - HydroPump

Series ES

Size Range ES025‐ES071

Size Available (Tons) 2, 3, 4, 5, 6

GLHP Efficiency EER 15.5‐24.5

COP 3.6‐4.0

GWHP Efficiency EER 19.0‐30.0

COP 4.0‐4.6

WLHP Efficiency EER 13.5‐17.5

COP 4.4‐5.4

Stages 2 Stage

Configuration VT, HZ, CF

Compressor Ultra Tech

Blower ECM

Auxiliary Heat Internal

Hot Gas Re‐Heat Optional

Hot Gas By‐Pass Optional

Evaporator Coil Uncoated, Tin‐plated

Desuperheater Optional

Compressor Noise Reduction Standard

Stainless Steel Drain Pan Standard

Energy Star Qualified Closed Loop: ES025‐ES061 (VT, HZ, CF)

Open Loop: ES025‐ES071 (VT, HZ, CF)

ES Series Guide Specifications

Page 2: ES Series Guide Specifications - HydroPump

AB

CD

EF

GH

JK

MN

PQ

Wid

thD

epth

Hei

ght

Dis

char

ge

Dep

thD

isch

arge

W

idth

Cab

inet

E

dge

to

Dis

char

ge

Left

Sid

e to

D

isch

arge

Wat

er In

Bot

tom

to

Con

dens

ate

Dra

inW

ater

Out

R/A

Duc

tW

idth

R/A

Duc

tFl

ange

Hei

ght

Filte

rR

ack

Hei

ght

Rig

ht S

ide

to

Dis

char

ge

ES

025

21.5

026

.00

47.2

513

.75

15.7

56.

135.

252.

508.

0013

.50

22.0

022

.00

24.0

04.

003/

4" F

PT

24 X

24

ES

035

21.5

026

.00

47.2

513

.75

15.7

56.

135.

252.

508.

0013

.50

22.0

022

.00

24.0

04.

003/

4" F

PT

24 X

24

ES

049

24.0

032

.75

47.2

515

.75

15.7

58.

385.

502.

508.

0014

.75

28.5

022

.00

24.0

04.

001"

FP

T24

X 3

0E

S06

126

.00

33.2

551

.25

17.7

517

.75

7.13

6.25

2.50

8.00

14.7

528

.50

22.0

024

.00

4.00

1" F

PT

24 X

30

ES

071

26.0

033

.25

58.2

517

.75

17.7

58.

007.

752.

508.

0014

.75

28.5

030

.00

32.0

01.

501"

FP

T16

X 3

0 (2

)

Mod

elC

onde

nser

Wat

erC

onne

ctio

ns

Rec

omm

ende

dR

epla

cem

ent

Nom

inal

Filte

r Siz

e - 1

" or

2" th

ick

Left

Han

d R

etur

n (F

LT)

R

ight

Han

d R

etur

n (F

RT)

NO

TES

: All

dim

ensi

ons

with

in +

/- 0.

125"

. A

ll co

nden

sate

dra

in c

onne

ctio

ns a

re 3

/4" F

PT.

All

Hea

t Rec

over

y K

it co

nnec

tions

are

1/2

" FP

T.

Inte

rnal

ele

ctric

hea

t ava

ilabl

e on

208

-230

/1/6

0 to

p di

scha

rge

units

onl

y In

tern

al H

eat R

ecov

ery

Kit

avai

labl

e on

208

-230

vol

t uni

ts o

nly.

S

peci

ficat

ions

sub

ject

to c

hang

e w

ithou

t not

ice.

ES Series Vertical Dimensions

ES

Ser

ies

Ver

tica

l Dim

ensi

ons

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 3: ES Series Guide Specifications - HydroPump

AB

CD

EF

GH

JK

MN

PQ

RT

Wid

thD

epth

Hei

ght

Cab

End

to

Filt

er

Rac

k

R/A

Duc

tW

idth

Cab

Fro

nt

to F

ilter

R

ack

Wat

er In

Wat

er O

utS

ide

to

Dis

char

geD

isch

arge

W

idth

Top

to

Dis

char

ge

(FLE

&

FRS

)

Dis

char

ge

Hei

ght

End

to

Dis

char

geTo

p to

D

isch

arge

Filte

rR

ack

Hei

ght

R/A

Duc

tFl

ange

Hei

ght

ES

025

26.0

054

.50

21.7

52.

0030

.00

22.5

02.

5013

.50

4.50

13.7

53.

0015

.75

4.50

3.00

20.0

018

.00

3/4"

FP

T20

X 3

0E

S03

526

.00

54.5

021

.75

2.00

30.0

022

.50

2.50

13.5

04.

5013

.75

3.00

15.7

54.

503.

0020

.00

18.0

03/

4" F

PT

20 X

30

ES

049

30.0

068

.00

21.7

52.

5033

.50

32.0

02.

5014

.50

5.81

15.7

53.

0015

.75

5.81

2.00

20.0

018

.00

1" F

PT

20 X

34.

5E

S06

130

.00

68.0

021

.75

2.50

33.5

032

.00

2.50

14.5

07.

6617

.75

2.00

17.7

57.

662.

0020

.00

18.0

01"

FP

T20

X 3

4.5

ES

071

30.0

078

.00

21.7

52.

5044

.00

31.5

02.

5014

.50

3.50

17.7

52.

7517

.75

7.66

1.00

20.0

018

.00

1" F

PT

20 X

24

(2)

Mod

elC

onde

nser

Wat

erC

onne

ctio

ns

Rec

omm

ende

dR

epla

cem

ent

Nom

inal

Filte

r Siz

e - 1

" or

2" th

ick

NO

TES

: A

ll di

men

sion

s w

ithin

+/-

0.12

5".

All

cond

ensa

te d

rain

con

nect

ions

are

3/4

" FP

T.

All

Hea

t Rec

over

y co

nnec

tions

are

1/2

" FP

T.

Inte

rnal

ele

ctric

hea

t ava

ilabl

e on

208

-230

vol

t u

nits

onl

y

Inte

rnal

Hea

t Rec

over

y K

it av

aila

ble

on 2

08-2

30

vol

t uni

ts o

nly.

Uni

ts c

an b

e fie

ld c

onve

rted

betw

een

end

blow

a

nd s

traig

ht th

roug

h su

pply

air

confi

gura

tions

.

Spe

cific

atio

ns s

ubje

ct to

cha

nge

with

out

not

ice.

Acc

ess

Pan

el

Ret

urn

Air

Op

enin

gR

etu

rn A

irO

pen

ing

Ret

urn

Air

Op

enin

gR

etu

rn A

irO

pen

ing

Acc

ess

Pan

el

Co

nd

ense

rW

ater

Ou

t

Co

nd

ensa

teD

rain

Co

nd

ensa

teD

rain

Co

nd

ensa

teD

rain

Co

nd

ensa

teD

rain

Co

nd

ense

rW

ater

In

Ele

ctri

cal

Kn

ock

-ou

ts

D

E

F

G

BH

AA

D

E

F

Q

QC

C

CC

P

PN

N

N

N

M

M

B

BB

AA

J

J

K

K K

K

Lef

t H

and

Ret

urn

En

d B

low

(F

LE

)L

eft

Han

d R

etu

rnS

trai

gh

t T

hro

ug

h (

FL

S)

Lef

t H

and

Ret

urn

Rig

ht

Han

d R

etu

rnE

nd

Blo

w (

FR

E)

Rig

ht

Han

d R

etu

rnS

trai

gh

t T

hro

ug

h (

FR

S)

Rig

ht

Han

d R

etu

rn

ES Series Horizontal DimensionsE

S S

erie

s H

oriz

onta

l Dim

ensi

ons

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 4: ES Series Guide Specifications - HydroPump

AB

CD

EF

GH

JK

MN

P

Wid

thD

epth

Hei

ght

Dis

char

ge

Dep

thD

isch

arge

W

idth

Cab

inet

E

dge

to

Dis

char

ge

Left

Sid

e to

D

isch

arge

Wat

er O

utW

ater

InR

ight

Sid

e to

D

isch

arge

R/A

Duc

tW

idth

R/A

Duc

tFl

ange

Hei

ght

Filte

rR

ack

Hei

ght

ES

025

21.5

026

.00

47.2

59.

2510

.25

6.00

5.50

8.50

19.5

09.

7522

.00

22.0

024

.00

3/4"

FP

T24

X 2

4E

S03

521

.50

26.0

047

.25

9.25

10.2

56.

005.

508.

5019

.50

9.75

22.0

022

.00

24.0

03/

4" F

PT

24 X

24

ES

049

24.0

032

.75

47.2

510

.75

11.5

011

.13

6.88

7.50

18.5

08.

7528

.00

22.0

024

.00

1" F

PT

24 X

30

ES

061

26.0

033

.25

51.2

512

.00

12.5

08.

385.

009.

7521

.75

10.5

028

.00

22.0

024

.00

1" F

PT

24 X

30

ES

071

26.0

033

.25

58.2

512

.75

13.5

09.

754.

507.

0020

.25

11.0

028

.00

30.0

032

.00

1" F

PT

16 X

30

(2)

Mod

elC

onde

nser

Wat

erC

onne

ctio

ns

Rec

omm

ende

dR

epla

cem

ent

Nom

inal

Filte

r Siz

e

Left

Han

d R

etur

n(F

LB)

Rig

ht H

and

Ret

urn

(FR

B)

NO

TES

: All

dim

ensi

ons

with

in +

/- 0.

125"

.

All

cond

ensa

te d

rain

con

nect

ions

are

3/4

" FP

T.

All

Hea

t Rec

over

y K

it co

nnec

tions

are

1/2

" FP

T.

Inte

rnal

ele

ctric

hea

t ava

ilabl

e on

208

-230

/1/6

0 bo

ttom

dis

char

ge u

nits

onl

y

Inte

rnal

Hea

t Rec

over

y K

it av

aila

ble

on 2

08-2

30 v

olt u

nits

onl

y.

Spe

cific

atio

ns s

ubje

ct to

cha

nge

with

out n

otic

e.

ES Series Counterflow DimensionsE

S S

erie

s C

ount

erfl

ow D

imen

sion

s

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 5: ES Series Guide Specifications - HydroPump

ASHRAE/AHRI/ISO 13256-1. English (I-P) Units

Capacity

BtuhEER

Capacity

BtuhCOP

Capacity

BtuhEER

Capacity

BtuhCOP

Capacity

BtuhEER

Capacity

BtuhCOP

ES025 26000 16.0 30000 5.0 29000 24.0 25000 4.6 27500 18.7 19000 3.8ES035 36000 14.6 43000 4.8 42000 21.6 36000 4.2 38000 17.2 28000 3.8ES049 48000 12.6 58000 4.8 54000 19.0 48000 4.2 49000 15.5 38000 3.6ES061 60000 14.0 72000 4.7 68000 19.7 61000 4.3 62000 15.7 49000 3.6ES071 72000 14.5 80000 4.5 77000 19.6 68000 4.2 74000 16.3 53000 3.5

ASHRAE/AHRI/ISO 13256-1. English (I-P) Units

Capacity

BtuhEER

Capacity

BtuhCOP

Capacity

BtuhEER

Capacity

BtuhCOP

Capacity

BtuhEER

Capacity

BtuhCOP

ES025 18800 17.5 20500 5.1 21000 30.0 18000 4.6 20000 24.5 15500 4.0ES035 24000 17.0 27000 5.3 27000 28.0 22500 4.5 27000 24.5 20500 4.0ES049 34000 16.0 39000 5.4 38000 24.0 32000 4.6 36000 21.8 28500 4.0ES061 42000 17.0 48000 5.4 48000 26.0 40000 4.6 45000 23.5 36500 4.0ES071 51000 15.8 55000 4.4 57000 25.2 47000 4.0 56000 21.8 42000 3.7

ES Series Certified Performance Data

Models

Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump

Cooling 86 deg.F Heating 68 deg.F Cooling 59 deg.F Heating 50 deg.F

Heating 50 deg.F Cooling 77 deg.F Heating 32 deg.F

Pa

rt L

oa

d

Cooling 77 deg.F Heating 32 deg.F

Fu

ll L

oa

d

Models

Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump

Cooling 86 deg.F Heating 68 deg.F Cooling 59 deg.F

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 6: ES Series Guide Specifications - HydroPump

Blower Performance Data - ECM Constant CFM Motor - EON

Adjust 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00Hi 600 + A 600 600 600 600 600 600 600 600 - -

Med 500 Normal A 500 500 500 500 500 500 500 500 - -Low 425 - A 425 425 425 425 425 425 425 425 - -Hi 900 + A 900 900 900 900 900 900 900 900 - -

Med 750 Normal A 750 750 750 750 750 750 750 750 - -Low 650 - A 650 650 650 650 650 650 650 650 - -Hi 1200 + A 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200

Med 1050 Normal A 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050Low 900 - A 900 900 900 900 900 900 900 900 900 900Hi 1400 + A 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400

Med 1225 Normal A 1225 1225 1225 1225 1225 1225 1225 1225 1225 1225Low 1050 - A 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050Hi 1100 + B 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100

Med 925 Normal B 925 925 925 925 925 925 925 925 925 925Low 800 - B 800 800 800 800 800 800 800 800 800 800Hi 1700 + B 1700 1700 1700 1700 1700 1700 1700 1700 1700 1700

Med 1500 Normal B 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500Low 1275 - B 1275 1275 1275 1275 1275 1275 1275 1275 1275 1275Hi 1725 + A 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725

Med 1500 Normal A 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500Low 1275 - A 1275 1275 1275 1275 1275 1275 1275 1275 1275 1275Hi 2300 + A 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300

Med 2000 Normal A 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000Low 1700 - A 1700 1700 1700 1700 1700 1700 1700 1700 1700 1700Hi 1850 + A 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850

Med 1600 Normal A 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600Low 1500 - A 1525 1525 1525 1525 1525 1525 1525 1525 1525 1525Hi 2300 + A 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300

Med 2200 Normal A 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250Low 1900 - A 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900

071- Part Load

071- Full Load

025- Part Load

025- Full Load

035- Part Load

035- Full Load

049- Part Load

ES Series Blower Performance - ECM

049- Full Load

061- Part Load

061- Full Load

Models Fan SpeedRated Airflow Tap

External Static Pressure (in of Water)

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 7: ES Series Guide Specifications - HydroPump

Physical Data025 035 049 061 071

Compressor Type (Qty 1) Scroll Scroll Scroll Scroll ScrollMax Water Working Pressure (PSIG/kPa) 450/3100 450/3100 450/3100 450/3100 450/3100

ECM Const AirFlow -Eon Fan Motor & Blower

Fan Motor Type/Speeds ECM Const Air Flow ECM Const Air Flow ECM Const Air Flow ECM Const Air Flow ECM Const Air Flow Fan Motor (HP) 0.33 0.50 0.75 1.00 1.00

Blower Wheel Size (Dia. x W) 9x7 9x7 10x8 11x9 11x9Water Connection Size

FPT 3/4" 3/4" 1" 1" 1"Coaxial Coil Volume (gal) 0.46 0.46 0.64 0.74 1.05

Vertical Cabinet

Refrigeration Charge (oz) 68 68 78 90 111Air Coil Dimensions (H x W) 24 X 21 24 X 21 24 X 27 24 X 27 32 X 27

Nominal size of Standard Filter - 1" (L x H) 24 X 24 24 X 24 24 X 30 24 X 30 16 X 30 (2)Weight - Operating (lbs) 290 290 318 390 450Weight - Shipping (lbs) 315 315 348 415 495

Horizontal Cabinet

Refrigeration Charge (oz) 68 68 78 90 111Air Coil Dimensions (H x W) 18 X 28 18 X 28 20 X 32.5 20 X 32.5 20 X 43

Nominal size of Standard Filter - 1" (L x H) 20 X 30 20 X 30 20 X 34.5 20 X 34.5 20 X 24 (2)Weight - Operating (lbs) 290 290 318 390 450Weight - Shipping (lbs) 315 315 348 415 495

ES Series Physical Data

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 8: ES Series Guide Specifications - HydroPump

Electrical Data Table - Constant CFM Motor

QTY RLA LRA FLAMin Circuit

Amps

Max Fuse/

HACR

1 208-230/60/1 197/253 1 10.3 52.0 2.8 15.7 252 265-277/60/1 - 1 9.0 67.0 2.6 13.9 201 208-230/60/1 197/253 1 16.7 82.0 4.3 25.2 403 208-230/60/3 197/253 1 11.2 58.0 4.3 18.3 254 460/60/3 - 1 4.5 29.0 4.1 9.7 151 208-230/60/1 197/253 1 21.2 96.0 6.8 33.3 503 208-230/60/3 197/253 1 13.5 88.0 6.8 23.7 354 460/60/3 - 1 6.4 41.0 5.5 13.5 151 208-230/60/1 197/253 1 25.6 118.0 6.8 38.8 603 208-230/60/3 197/253 1 17.6 123.0 6.8 28.8 454 460/60/3 - 1 9.0 62.0 5.5 16.8 251 208-230/60/1 197/253 1 27.2 150.0 6.8 40.8 603 208-230/60/3 197/253 1 19.7 123.0 6.8 31.4 504 460/60/3 - 1 9.9 62.0 6.9 19.3 25

Units with Factory Installed Electric Heat option will have two separate data plates for each electrical circuit

1st Data plate is for compressor power connection

QTY RLA LRA

Min

Circuit

Amps

Max Fuse/

HACR

ES025 1 208-230/60/1 197/253 1 11.7 58.3 14.6 25ES035 1 208-230/60/1 197/253 1 15.3 83.0 19.1 30ES049 1 208-230/60/1 197/253 1 21.2 104.0 26.5 45ES061 1 208-230/60/1 197/253 1 27.1 152.9 33.9 60ES071 1 208-230/60/1 197/253 1 29.7 179.2 37.1 60

For Units with Electric Heat Option

MODELEH RATED

kWSTAGE 240 208 240V 208V

Motor FLA (A) Fuses 240V 208V 240V 208V

ES025 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30ES035 4.8 1 4,800 3,600 20.0 17.3 4.3 - 30.4 27.0 35 35ES035 9.6 1 9,600 7,200 40.0 34.6 4.3 - 55.4 48.6 60 60ES049 4.8 1 4,800 3,600 20.0 17.3 6.8 - 33.5 30.1 35 35ES049 9.6 1 9,600 7,200 40.0 34.6 6.8 - 58.5 51.8 60 60

F1/F2 83.5F3/F4

ES061 4.8 1 4,800 3,600 20.0 17.3 9.1 - 36.4 33.0 40 35ES061 9.6 1 9,600 7,200 40.0 34.6 9.1 - 61.4 54.6 70 60

9.1 F1/F2 86.49.1 F3/F49.1 F1/F2 111.49.1 F3/F4

ES071 4.8 1 4,800 3,600 20.0 17.3 9.1 - 36.4 33.0 40 35ES071 9.6 1 9,600 7,200 40.0 34.6 9.1 - 61.4 54.6 70 60

F1/F2 86.4F3/F4F1/F2 111.4F3/F4

CompressorTotal Unit

w/ Constant CFM Motor

Models

ModelsVoltage

CodeRated Voltage

Voltage

Min/Max

ES025

ES035

ES049

ES061

ES071

73.4 90 80

Voltage

CodeRated Voltage

Voltage

Min/Max

Compressor Total Unit

14.4 2 14400 10800

76.3 90 80

ES061 19.2 2 19200 14000 80

ES061 14.4 2 14400 10800 60

97.9 125 100

ES071 14.4 2 14400 10800 60

97.9 125 100

51.9 9.1 76.3 90 80

ES Series Electrical Data

80 69.2 9.1ES071 19.2 2 19200 14000

69.2

51.9

60 51.9 6.8ES049

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 9: ES Series Guide Specifications - HydroPump

Model:

Size:

600

Unit

kWEER

0.78 27.90.78 29.50.79 31.30.73 30.00.74 32.00.75 33.90.69 32.30.70 34.60.70 36.90.90 23.00.91 24.30.92 25.80.86 24.50.86 26.00.87 27.70.82 26.20.82 27.90.82 29.91.03 19.01.04 20.21.05 21.30.99 20.10.99 21.51.00 22.70.95 21.30.95 22.80.95 24.41.17 15.71.18 16.71.19 17.71.13 16.61.14 17.61.14 18.81.09 17.51.09 18.71.10 20.01.25 14.31.26 15.21.27 16.11.21 15.01.21 16.01.22 17.11.17 15.81.17 17.01.17 18.11.33 13.01.34 13.81.35 14.71.29 13.61.29 14.61.30 15.61.25 14.31.25 15.41.25 16.41.50 10.71.51 11.41.52 12.21.46 11.31.46 12.01.47 12.81.42 11.71.42 12.61.42 13.51.69 8.81.69 9.51.70 10.11.65 9.21.65 9.91.65 10.61.61 9.61.61 10.31.61 11.1

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

ES Series Capacity Data

Pressure

Drop

(Psi)

0.6

1.0

2.0

0.6

0.9

1.923.9

80/67 22.8 16.3 25.585/71 24.5 16.7 27.2

23.680/67 22.4 16.1 25.285/71

20.980/67 17.9 14.3 22.185/71 23.5

20.780/67 17.5 14.2 22.085/71

19.980/67 16.0 13.6 21.185/71 17.1 14.1 22.3

21.485/71 17.8 14.3 22.6

20.080/67 16.3 13.7 21.285/71 17.5 14.2 22.4

20.2

110

3 1.175/63 14.9 13.1

4 1.875/63 15.2 13.2

6 3.875/63 15.4 13.3

0.5

0.8

1.6 80/67 16.6 13.8

23.3

20.580/67 17.2 14.1 21.885/71 18.4 14.6 23.0

100

3 1.175/63 16.1 13.6

4 1.975/63 16.4 13.7

6 3.975/63 16.6 13.8

0.5

0.8

1.719.2 14.8

18.8 14.7

21.680/67 19.2 14.8 23.085/71 20.5 15.3 24.4

21.480/67 18.8 14.7 22.785/71 20.2 15.1 24.2

21.280/67 18.4 14.6 22.585/71 19.7 15.0 23.9

90

3 1.275/63 17.2 14.0

4 1.975/63 17.5 14.2

6 475/63 17.8 14.3

0.5

0.8

1.7

22.080/67 19.8 15.1 23.485/71 21.2 15.5 24.9

21.880/67 19.4 14.9 23.185/71 20.8 15.4 24.6

21.680/67 19.1 14.8 22.985/71 20.4 15.3 24.3

85

3 1.275/63 17.8 14.3

4 275/63 18.1 14.4

6 4.175/63 18.4 14.5

0.5

0.9

1.8

22.380/67 20.4 15.3 23.885/71 21.9 15.8 25.3

22.180/67 20.0 15.2 23.585/71 21.5 15.6 25.0

21.980/67 19.7 15.0 23.385/71 21.0 15.5 24.7

80

3 1.275/63 18.4 14.5

4 275/63 18.7 14.6

6 4.175/63 19.0 14.8

0.5

0.9

1.8

23.180/67 21.6 15.8 24.685/71 23.2 16.2 26.3

22.980/67 21.3 15.6 24.485/71 22.7 16.1 25.9

22.680/67 20.9 15.5 24.185/71 22.3 16.0 25.6

70

3 1.275/63 19.5 15.0

4 2.175/63 19.8 15.1

6 4.375/63 20.1 15.3

0.9

1.9

0.5

26.8

23.480/67 22.0 16.0 24.985/71 23.6 16.4 26.5

60

3 1.375/63 20.6 15.5

4 2.175/63 20.9 15.6

6 4.475/63 21.3 15.8

24.0 16.5

85/71 25.2 17.0 27.7

6 4.675/63 22.4 16.2 24.680/67 24.0 16.8 26.385/71 25.7 17.2 28.0

24.8 16.8 27.416.1 24.4

80/67 23.6 16.6 26.0

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

3 1.375/63 21.6 15.9

4 2.275/63 22.0

24.180/67 23.1 16.4 25.785/71

Cooling Performance Data Report

ES025

CAPACITY DATA All performance at CFM Unit Load: Partial Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 10: ES Series Guide Specifications - HydroPump

Model:

Size:

900

Unit

kWEER

1.49 18.91.51 19.81.54 20.71.44 19.91.46 21.11.47 22.11.39 21.01.40 22.31.41 23.71.63 16.51.65 17.31.68 18.11.57 17.51.59 18.41.61 19.41.51 18.51.53 19.61.54 20.71.78 14.31.81 15.01.85 15.71.72 15.21.74 15.91.77 16.71.66 16.01.68 16.91.70 17.81.96 12.42.00 12.92.04 13.51.89 13.11.92 13.71.95 14.41.83 13.71.85 14.61.88 15.32.06 11.42.10 12.02.13 12.61.99 12.12.02 12.72.05 13.31.93 12.71.95 13.41.98 14.22.16 10.62.20 11.12.24 11.72.09 11.22.13 11.72.16 12.42.03 11.72.05 12.42.08 13.12.38 9.02.42 9.52.46 10.02.32 9.52.34 10.02.38 10.62.25 9.92.27 10.52.30 11.12.63 7.72.66 8.12.70 8.52.56 8.02.59 8.52.62 9.02.50 8.32.52 8.92.55 9.4

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

ES Series Capacity Data

Cooling Performance Data Report

ES025

CAPACITY DATA All performance at CFM Unit Load: Full Load

Pressure

Drop

(Psi)

COOLING

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

3 1.375/63 28.1 21.9

4 2.275/63 28.6

0.6

1.0

2.06 4.675/63 29.2 22.4

85/71 33.3 23.8

32.980/67 29.9 22.6 34.885/71 31.8 23.2 36.8

33.7

22.2 33.380/67 30.6 22.9 35.3

80/67 31.2 23.1 35.837.9

85/71 32.5 23.5 37.4

60

3 1.375/63 26.8 21.4

4 2.175/63 27.4

0.6

0.9

1.9

31.980/67 28.5 22.1 33.885/71 30.4 22.7 35.8

6 4.475/63 27.9 21.8 32.7

21.6 32.480/67 29.2 22.3 34.3

80/67 29.8 22.6 34.785/71 31.8 23.2 36.8

85/71 31.1 22.9 36.3

70

3 1.275/63 25.5 20.9

4 2.175/63 26.0

0.5

0.9

1.9

31.180/67 27.2 21.5 32.985/71 28.9 22.2 34.8

6 4.375/63 26.5 21.3 31.8

21.1 31.480/67 27.7 21.8 33.3

80/67 28.3 22.0 33.785/71 30.2 22.7 35.7

85/71 29.5 22.4 35.2

80

3 1.275/63 24.2 20.3

4 275/63 24.7

0.5

0.9

1.8

30.380/67 25.8 21.0 32.185/71 27.4 21.7 33.8

6 4.175/63 25.1 20.7 30.9

20.5 30.680/67 26.3 21.2 32.4

80/67 26.9 21.4 32.785/71 28.6 22.1 34.6

85/71 28.0 21.9 34.2

85

3 1.275/63 23.5 20.0

4 275/63 24.0

0.5

0.9

1.86 4.175/63 24.4 20.4

85/71 27.9 21.8

29.980/67 25.1 20.7 31.685/71 26.7 21.4 33.4

30.4

20.2 30.280/67 25.6 20.9 32.0

80/67 26.1 21.1 32.334.1

85/71 27.3 21.6 33.8

90

3 1.275/63 22.8 19.2

4 1.975/63 23.3

0.5

0.8

1.7

29.580/67 24.4 20.5 31.285/71 26.0 21.1 33.0

6 475/63 23.7 20.1 30.0

19.9 29.880/67 24.9 20.7 31.5

80/67 25.4 20.9 31.885/71 27.1 21.6 33.6

85/71 26.6 21.3 33.4

100

3 1.175/63 21.5 18.7

4 1.975/63 21.9

0.5

0.8

1.7

28.880/67 23.0 19.4 30.585/71 24.5 20.7 32.2

6 3.975/63 22.3 19.0 29.2

18.9 29.080/67 23.4 20.1 30.7

80/67 23.9 20.3 31.085/71 25.5 21.0 32.7

85/71 25.1 20.8 32.5

110

3 1.175/63 20.1 18.1

4 1.875/63 20.5

0.5

0.8

1.6

28.280/67 21.5 18.7 29.885/71 23.0 19.6 31.4

6 3.875/63 20.8 18.3 28.5

18.2 28.380/67 22.0 18.9 30.0

80/67 22.3 19.2 30.285/71 24.0 20.4 31.9

85/71 23.5 19.7 31.7

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 11: ES Series Guide Specifications - HydroPump

Model:

Size:

1050

Unit

kWEER

1.22 23.11.25 24.41.28 25.41.18 24.41.20 25.71.23 26.91.13 25.81.15 27.21.18 28.61.38 19.51.40 20.71.43 21.71.33 20.51.35 21.71.38 22.91.29 21.61.31 22.91.33 24.11.54 16.61.56 17.51.59 18.51.49 17.31.52 18.41.54 19.41.45 18.11.47 19.31.49 20.41.72 13.91.74 14.81.77 15.71.67 14.61.69 15.51.71 16.41.63 15.21.64 16.21.66 17.31.82 12.81.84 13.61.87 14.41.77 13.31.79 14.21.81 15.11.73 13.91.74 14.91.76 15.91.93 11.71.95 12.51.97 13.31.88 12.11.90 13.01.91 13.91.83 12.71.85 13.61.86 14.52.17 9.72.18 10.42.20 11.22.11 10.12.13 10.92.14 11.62.06 10.52.07 11.32.08 12.22.44 8.02.45 8.72.46 9.32.38 8.42.39 9.02.40 9.72.33 8.72.33 9.42.34 10.1

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

27.180/67 21.2 20.5

ES Series Capacity Data

Pressure

Drop

(Psi)

1.2

2.0

4.1

1.1

1.9

3.931.9

80/67 29.9 24.4 34.185/71 32.1 25.3 36.4

31.680/67

27.280/67 21.6 20.6 29.085/71 23.3 22.3 30.8

27.380/67 21.9 20.7 29.185/71 23.6 22.4 30.9

28.885/71 22.9 21.6 30.6

110

4.5 2.275/63 19.6 19.4

6 3.775/63 19.9 19.6

9 7.875/63 20.2 19.7

1.0

1.6

3.4

28.080/67 23.5 22.0 29.985/71 25.3 23.0 31.9

27.980/67 23.1 21.9 29.785/71 24.9 22.9 31.6

27.780/67 22.8 21.8 29.585/71 24.6 22.7 31.4

100

4.5 2.375/63 21.1 20.1

6 3.875/63 21.4 20.3

9 875/63 21.7 20.4

1.0

1.6

3.5

28.980/67 25.1 22.6 30.985/71 27.0 23.5 32.9

28.780/67 24.7 22.5 30.685/71 26.6 23.4 32.6

28.580/67 24.3 22.4 30.485/71 26.2 23.3 32.4

90

4.5 2.475/63 22.5 21.4

6 475/63 22.8 21.5

9 8.275/63 23.2 21.6

1.0

1.7

3.6

29.480/67 25.9 22.9 31.485/71 27.9 23.8 33.5

29.180/67 25.5 22.7 31.185/71 27.4 23.7 33.2

28.980/67 25.1 22.6 30.985/71 27.0 23.5 32.9

85

4.5 2.475/63 23.3 21.7

6 475/63 23.6 21.8

9 8.475/63 24.0 21.9

1.0

1.7

3.6

29.880/67 26.7 23.2 31.985/71 28.8 24.1 34.1

29.680/67 26.3 23.1 31.685/71 28.2 24.0 33.7

29.480/67 25.9 22.9 31.485/71 27.8 23.8 33.4

80

4.5 2.475/63 24.0 21.9

6 4.175/63 24.4 22.1

9 8.575/63 24.7 22.3

1.0

1.8

3.7

30.980/67 28.3 23.8 33.085/71 30.4 24.7 35.2

30.680/67 27.9 23.7 32.785/71 29.9 24.6 34.9

30.480/67 27.4 23.5 32.485/71 29.4 24.4 34.5

70

4.5 2.575/63 25.5 22.5

6 4.275/63 25.9 22.7

9 8.875/63 26.3 22.9

3.8

1.1

1.8

36.0

31.380/67 29.0 24.0 33.585/71 31.0 24.9 35.7

29.4 24.2 33.885/71

60

4.5 2.675/63 26.9 23.1

6 4.475/63 27.3 23.3

9 9.175/63 27.8 23.5

31.5 25.1

85/71 33.1 25.6 37.2

9 9.475/63 29.2 24.1 32.980/67 31.4 25.0 35.285/71 33.7 25.8 37.6

32.6 25.4 36.823.9 32.6

80/67 30.9 24.8 34.9

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

4.5 2.775/63 28.3 23.7

6 4.575/63 28.8

32.380/67 30.5 24.6 34.585/71

Cooling Performance Data Report

ES035

CAPACITY DATA All performance at CFM Unit Load: Partial Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 12: ES Series Guide Specifications - HydroPump

Model:

Size:

1225

Unit

kWEER

2.08 18.92.10 19.92.14 21.02.00 20.02.02 21.22.04 22.31.92 21.21.93 22.51.95 23.92.27 16.52.30 17.42.33 18.42.19 17.42.21 18.52.24 19.52.11 18.42.13 19.62.15 20.72.48 14.42.50 15.22.53 16.12.40 15.12.42 16.12.44 17.02.32 15.92.34 16.92.35 18.12.70 12.42.73 13.22.76 14.02.62 13.12.64 13.92.66 14.82.55 13.72.56 14.72.57 15.62.82 11.62.85 12.32.88 13.02.74 12.12.76 13.02.78 13.82.67 12.72.68 13.62.70 14.52.95 10.82.98 11.43.01 12.12.87 11.32.89 12.02.91 12.82.79 11.82.81 12.62.82 13.53.22 9.33.25 9.93.29 10.53.14 9.73.16 10.33.19 11.03.07 10.13.08 10.83.10 11.63.52 7.93.56 8.43.60 9.03.44 8.33.47 8.83.49 9.43.37 8.63.38 9.23.41 9.8

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

39.180/67 30.0 25.7

ES Series Capacity Data

Pressure

Drop

(Psi)

1.2

2.0

4.1

1.1

1.9

3.945.7

80/67 41.7 30.9 48.685/71 44.6 31.8 51.7

45.280/67

39.480/67 30.7 25.8 41.785/71 32.9 26.8 44.1

39.680/67 31.2 26.1 41.985/71 33.5 27.0 44.4

41.385/71 32.3 26.5 43.7

110

4.5 2.275/63 28.0 24.5

6 3.775/63 28.5 24.7

9 7.875/63 29.0 24.9

1.0

1.6

3.4

40.780/67 33.3 27.0 43.185/71 35.8 28.8 45.7

40.480/67 32.7 26.8 42.785/71 35.1 27.8 45.2

40.180/67 32.1 26.5 42.485/71 34.4 27.4 44.9

100

4.5 2.375/63 29.9 25.3

6 3.875/63 30.5 25.6

9 875/63 31.0 25.7

1.0

1.6

3.5

41.880/67 35.5 27.7 44.585/71 38.1 29.5 47.2

41.480/67 34.8 28.2 44.085/71 37.3 29.3 46.7

41.180/67 34.1 27.2 43.685/71 36.5 29.0 46.1

90

4.5 2.475/63 31.8 26.2

6 475/63 32.4 26.6

9 8.275/63 32.9 26.8

1.0

1.7

3.6

42.580/67 36.5 29.0 45.185/71 39.2 29.9 47.9

42.080/67 35.8 28.1 44.685/71 38.4 29.7 47.3

41.780/67 35.1 28.4 44.285/71 37.5 29.4 46.8

85

4.5 2.475/63 32.7 26.7

6 475/63 33.3 27.0

9 8.475/63 34.0 27.1

1.0

1.7

3.6

43.180/67 37.6 29.3 45.985/71 40.3 30.4 48.6

42.680/67 36.8 29.1 45.385/71 39.4 30.1 48.0

42.280/67 36.2 28.7 44.985/71 38.7 29.7 47.5

80

4.5 2.475/63 33.6 27.1

6 4.175/63 34.3 27.4

9 8.575/63 35.0 27.5

1.0

1.8

3.7

44.480/67 39.6 30.2 47.285/71 42.5 31.2 50.1

44.080/67 38.9 29.9 46.785/71 41.6 30.8 49.5

43.580/67 38.1 29.6 46.285/71 40.7 30.5 48.9

70

4.5 2.575/63 35.6 27.8

6 4.275/63 36.3 28.1

9 8.875/63 37.0 28.4

3.8

1.1

1.8

51.0

44.780/67 40.1 30.3 47.585/71 42.8 31.1 50.4

40.9 30.6 48.185/71

60

4.5 2.675/63 37.4 29.3

6 4.475/63 38.1 29.6

9 9.175/63 38.9 29.9

43.7 31.5

85/71 45.7 32.3 52.4

9 9.475/63 40.7 30.7 46.980/67 43.6 31.7 50.085/71 46.6 32.7 53.1

44.8 31.9 51.830.4 46.4

80/67 42.8 31.3 49.4

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

4.5 2.775/63 39.2 30.1

6 4.575/63 39.9

45.980/67 41.9 31.0 48.885/71

Cooling Performance Data Report

ES035

CAPACITY DATA All performance at CFM Unit Load: Full Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 13: ES Series Guide Specifications - HydroPump

Model:

Size:

1100

Unit

kWEER

1.62 22.61.60 24.31.58 26.21.55 23.91.53 25.81.50 28.11.49 25.41.46 27.51.43 30.11.80 19.31.78 20.71.76 22.31.73 20.31.71 21.91.69 23.71.67 21.61.64 23.31.61 25.42.01 16.41.99 17.61.97 19.01.94 17.31.92 18.61.89 20.11.87 18.21.84 19.71.81 21.52.25 13.82.23 14.92.21 16.02.17 14.52.15 15.72.13 16.92.10 15.32.07 16.62.04 18.02.38 12.72.36 13.62.34 14.62.30 13.32.28 14.42.26 15.52.23 14.12.20 15.22.17 16.42.52 11.62.50 12.52.48 13.52.44 12.22.42 13.12.39 14.22.36 12.82.34 13.92.31 15.02.83 9.72.81 10.42.78 11.32.75 10.12.73 10.92.69 11.92.67 10.62.64 11.52.60 12.53.19 8.03.16 8.73.12 9.43.11 8.33.07 9.13.02 9.93.02 8.72.98 9.52.93 10.4

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

35.480/67 27.4 23.3

ES Series Capacity Data

Pressure

Drop

(Psi)

1.3

2.3

4.7

1.3

2.2

4.641.3

80/67 38.3 28.4 43.685/71 40.9 29.1 46.1

40.980/67

35.680/67 27.9 23.5 37.585/71 29.9 24.5 39.4

35.780/67 28.4 23.7 37.785/71 30.4 24.7 39.6

37.385/71 29.4 24.2 39.2

110

6 2.675/63 25.5 22.3

8 4.375/63 25.9 22.5

12 975/63 26.3 22.7

1.1

1.9

3.9

36.780/67 30.4 24.5 38.685/71 32.5 26.2 40.7

36.480/67 29.8 24.4 38.385/71 31.9 25.4 40.4

36.280/67 29.3 24.0 38.185/71 31.4 25.0 40.1

100

6 2.775/63 27.4 23.1

8 4.575/63 27.8 23.4

12 9.275/63 28.3 23.6

1.2

2.0

4.0

37.780/67 32.4 26.1 39.785/71 34.6 27.0 41.9

37.480/67 31.8 25.9 39.485/71 34.0 26.7 41.6

37.180/67 31.3 25.6 39.185/71 33.4 26.4 41.2

90

6 2.775/63 29.2 24.0

8 4.675/63 29.7 24.2

12 9.575/63 30.3 24.5

1.2

2.0

4.1

38.280/67 33.4 26.5 40.385/71 35.7 27.2 42.6

37.980/67 32.8 26.2 40.085/71 35.0 27.1 42.1

37.680/67 32.2 26.0 39.785/71 34.3 26.9 41.7

85

6 2.875/63 30.2 24.4

8 4.775/63 30.7 24.8

12 9.775/63 31.3 24.9

1.2

2.0

4.2

38.880/67 34.4 26.9 41.085/71 36.7 27.7 43.2

38.480/67 33.8 26.6 40.685/71 36.0 27.5 42.8

38.180/67 33.2 26.4 40.285/71 35.4 27.1 42.4

80

6 2.875/63 31.1 24.9

8 4.775/63 31.6 25.2

12 9.875/63 32.2 26.0

1.2

2.0

4.3

40.080/67 36.4 27.6 42.385/71 38.9 28.4 44.7

39.680/67 35.7 27.4 41.885/71 38.1 28.1 44.2

39.380/67 35.1 27.1 41.485/71 37.4 27.9 43.7

70

6 2.975/63 32.9 26.3

8 4.975/63 33.5 26.5

12 10.275/63 34.1 26.8

4.4

1.3

2.1

45.5

40.480/67 37.0 27.8 42.785/71 39.3 28.6 45.0

37.6 28.1 43.185/71

60

6 375/63 34.7 27.0

8 5.175/63 35.3 27.3

12 10.575/63 36.0 27.6

40.0 28.9

85/71 42.1 29.5 47.0

12 10.975/63 37.8 28.4 42.680/67 40.2 29.2 45.085/71 42.9 29.9 47.6

41.3 29.2 46.428.0 42.1

80/67 39.5 28.8 44.4

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

6 3.175/63 36.5 27.7

8 5.275/63 37.1

41.780/67 38.8 28.6 43.985/71

Cooling Performance Data Report

ES049

CAPACITY DATA All performance at CFM Unit Load: Partial Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 14: ES Series Guide Specifications - HydroPump

Model:

Size:

1700

Unit

kWEER

3.01 16.63.05 17.53.09 18.42.90 17.62.93 18.62.96 19.62.78 18.82.81 19.92.84 21.13.22 14.83.26 15.73.29 16.53.11 15.73.14 16.63.17 17.63.00 16.73.02 17.73.05 18.83.45 13.23.49 14.03.52 14.73.34 14.03.37 14.83.40 15.73.22 14.83.25 15.83.27 16.73.71 11.63.75 12.43.78 13.03.59 12.33.62 13.13.65 13.93.47 13.13.50 13.93.52 14.83.85 10.93.89 11.63.93 12.23.73 11.53.76 12.33.79 13.03.61 12.23.63 13.03.65 13.94.01 10.24.05 10.84.08 11.43.88 10.83.91 11.43.94 12.23.76 11.43.78 12.23.80 12.94.36 8.84.40 9.44.44 9.94.23 9.34.25 9.94.28 10.64.09 9.84.11 10.54.13 11.34.76 7.64.81 8.04.85 8.54.63 8.04.66 8.54.68 9.04.49 8.44.51 9.04.52 9.6

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

51.380/67 38.6 33.3

ES Series Capacity Data

Pressure

Drop

(Psi)

1.3

2.3

4.7

1.3

2.2

4.659.9

80/67 53.6 39.7 63.585/71 57.4 40.7 67.4

59.180/67

51.780/67 39.5 33.7 54.585/71 42.3 35.0 57.5

52.180/67 40.5 34.1 55.085/71 43.5 35.4 58.1

54.185/71 41.2 34.7 56.9

110

6 2.675/63 36.1 31.9

8 4.375/63 36.9 32.2

12 975/63 37.7 32.6

1.1

1.9

3.9

53.480/67 43.3 35.3 56.585/71 46.5 36.4 59.9

52.980/67 42.2 34.9 55.985/71 45.2 36.2 59.0

52.480/67 41.2 34.5 55.385/71 44.0 35.8 58.3

100

6 2.775/63 38.4 33.0

8 4.575/63 39.4 33.4

12 9.275/63 40.3 33.9

1.2

2.0

4.0

55.180/67 46.0 36.5 58.285/71 49.2 37.8 61.6

54.480/67 44.8 36.0 57.585/71 47.9 37.4 60.7

53.880/67 43.7 35.6 56.885/71 46.7 36.8 60.0

90

6 2.775/63 40.9 34.2

8 4.675/63 41.9 34.6

12 9.575/63 43.0 34.8

1.2

2.0

4.1

55.880/67 47.3 37.1 59.085/71 50.7 38.1 62.6

55.180/67 46.3 36.3 58.485/71 49.2 37.9 61.5

54.580/67 45.2 35.8 57.785/71 48.0 37.4 60.7

85

6 2.875/63 42.1 34.7

8 4.775/63 43.1 35.1

12 9.775/63 44.1 35.6

1.2

2.0

4.2

56.680/67 48.6 37.5 60.085/71 51.9 38.9 63.4

55.980/67 47.5 36.9 59.285/71 50.6 38.4 62.5

55.280/67 46.4 36.4 58.585/71 49.3 37.9 61.6

80

6 2.875/63 43.2 35.3

8 4.775/63 44.3 35.7

12 9.875/63 45.4 36.1

1.2

2.0

4.3

58.280/67 51.3 38.4 61.885/71 54.8 39.7 65.5

57.480/67 49.9 38.1 60.885/71 53.4 39.1 64.5

56.780/67 48.7 37.7 60.085/71 51.9 38.8 63.4

70

6 2.975/63 45.6 36.3

8 4.975/63 46.6 36.8

12 10.275/63 47.8 37.3

4.4

1.3

2.1

66.2

58.380/67 51.1 38.6 61.785/71 54.3 39.9 65.1

52.3 39.2 62.685/71

60

6 375/63 47.8 37.3

8 5.175/63 48.9 37.8

12 10.575/63 50.1 38.4

55.8 40.4

85/71 58.2 41.4 68.0

12 10.975/63 52.4 39.4 61.580/67 56.0 40.7 65.385/71 59.8 42.0 69.1

56.8 40.8 66.938.8 60.6

80/67 54.6 40.2 64.2

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

6 3.175/63 50.0 38.3

8 5.275/63 51.1

59.880/67 53.3 39.6 63.385/71

Cooling Performance Data Report

ES049

CAPACITY DATA All performance at CFM Unit Load: Full Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 15: ES Series Guide Specifications - HydroPump

Model:

Size:

1500

Unit

kWEER

2.02 24.52.01 26.42.01 28.21.92 26.11.91 28.11.90 30.21.90 26.61.90 28.61.76 33.02.30 20.72.29 22.32.27 23.92.21 21.82.19 23.52.18 25.32.11 23.12.08 25.12.15 25.92.60 17.42.58 18.82.56 20.32.51 18.32.49 19.72.47 21.42.47 18.72.45 20.22.43 21.92.93 14.72.90 15.92.88 17.22.89 15.12.80 16.72.78 18.02.79 15.82.76 17.22.73 18.63.12 13.53.09 14.63.05 15.83.02 14.13.04 15.03.01 16.22.97 14.52.93 15.82.89 17.13.31 12.33.28 13.43.24 14.53.22 12.83.22 13.83.13 15.23.15 13.33.11 14.43.07 15.73.77 10.23.71 11.23.67 12.13.69 10.63.64 11.53.59 12.63.56 11.13.51 12.13.46 13.24.28 8.54.25 9.24.18 10.04.15 8.94.11 9.74.06 10.54.03 9.33.98 10.13.92 11.0

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

49.980/67 39.1 33.3

ES Series Capacity Data

Pressure

Drop

(Psi)

1.4

2.4

5.0

1.4

2.3

4.855.6

80/67 52.2 38.6 59.085/71 55.7 38.8 62.9

55.280/67

50.180/67 39.7 33.7 52.885/71 42.5 35.1 55.5

50.280/67 40.3 33.9 53.085/71 43.3 35.2 55.8

52.685/71 41.9 34.9 55.3

110

7.5 2.775/63 36.3 32.3

10 4.675/63 36.9 32.4

15 9.575/63 37.4 32.7

1.2

2.0

4.1

51.080/67 42.6 34.9 53.885/71 45.8 36.0 56.9

50.780/67 41.9 34.6 53.585/71 45.2 35.4 56.7

50.780/67 41.5 34.5 53.385/71 44.5 35.7 56.2

100

7.5 2.875/63 38.7 33.0

10 4.775/63 39.0 33.3

15 9.875/63 39.6 33.6

1.2

2.0

4.3

51.980/67 44.9 35.8 54.985/71 48.2 37.0 58.1

51.680/67 44.4 35.3 54.785/71 47.6 36.8 57.7

51.480/67 44.0 35.3 54.585/71 47.0 36.6 57.5

90

7.5 2.975/63 40.9 34.1

10 4.975/63 41.4 34.3

15 10.175/63 41.9 34.4

1.3

2.1

4.4

52.580/67 46.2 36.1 55.685/71 49.4 37.5 58.8

52.180/67 45.6 35.6 55.385/71 48.9 36.6 58.6

51.980/67 45.1 35.7 55.085/71 48.3 37.1 58.1

85

7.5 2.975/63 42.0 34.6

10 4.975/63 42.5 34.8

15 10.275/63 43.0 34.9

1.3

2.1

4.4

53.080/67 47.4 36.5 56.385/71 50.7 37.9 59.5

52.980/67 46.8 36.5 55.885/71 50.2 37.7 59.2

52.580/67 46.3 36.3 55.685/71 49.6 37.4 58.9

80

7.5 375/63 43.1 35.0

10 575/63 43.6 34.7

15 10.475/63 44.1 35.3

1.3

2.2

4.5

54.280/67 49.6 37.5 57.585/71 53.1 38.5 61.1

54.080/67 49.2 37.4 57.385/71 52.8 38.5 60.8

53.780/67 48.5 37.2 56.985/71 52.0 38.2 60.4

70

7.5 3.175/63 45.4 35.8

10 5.275/63 45.9 36.2

15 10.775/63 46.2 36.3

4.6

1.3

2.3

62.3

54.980/67 50.9 37.9 58.385/71 54.3 39.2 61.7

51.6 38.3 58.785/71

60

7.5 3.275/63 47.5 36.8

10 5.375/63 48.1 37.1

15 11.175/63 48.7 37.4

55.1 39.5

85/71 57.5 40.4 63.8

15 11.575/63 50.6 37.5 56.980/67 54.2 38.7 60.585/71 58.3 40.7 64.1

56.6 40.0 63.238.0 56.5

80/67 53.8 39.2 60.1

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

7.5 3.375/63 49.5 37.7

10 5.575/63 50.2

56.180/67 53.0 38.9 59.685/71

Cooling Performance Data Report

ES061

CAPACITY DATA All performance at CFM Unit Load: Partial Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 16: ES Series Guide Specifications - HydroPump

Model:

Size:

2000

Unit

kWEER

3.71 17.33.78 18.23.85 19.13.56 18.53.61 19.53.66 20.53.40 19.73.43 20.83.46 22.14.06 15.24.12 16.04.18 16.83.91 16.13.95 17.14.00 18.03.86 16.53.79 18.13.80 19.34.43 13.44.49 14.14.55 14.84.28 14.14.31 14.94.37 15.84.10 14.94.10 15.94.15 16.94.83 11.64.89 12.34.94 13.04.68 12.24.72 13.04.77 13.84.49 12.94.51 13.84.56 14.65.05 10.95.10 11.55.17 12.14.91 11.44.94 12.14.99 12.84.71 12.04.73 12.84.89 13.35.27 10.15.32 10.75.39 11.35.12 10.65.17 11.35.21 11.95.03 10.95.07 11.65.02 12.65.78 8.75.83 9.35.88 9.85.64 9.15.66 9.75.70 10.35.50 9.45.54 10.15.58 10.76.33 7.56.39 7.96.46 8.46.21 7.76.24 8.36.28 8.86.03 8.16.07 8.76.12 9.2

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

67.880/67 50.6 42.1

ES Series Capacity Data

Pressure

Drop

(Psi)

1.4

2.4

5.0

1.4

2.3

4.876.6

80/67 68.6 49.2 81.285/71 73.3 51.0 86.0

75.980/67

68.280/67 51.5 42.5 71.985/71 55.2 44.1 75.8

68.480/67 52.6 42.5 72.585/71 56.1 44.5 76.1

71.585/71 54.3 43.6 75.4

110

7.5 2.775/63 47.2 40.4

10 4.675/63 47.9 40.6

15 9.575/63 48.8 41.1

1.2

2.0

4.1

69.780/67 55.6 44.1 73.785/71 59.8 45.3 78.1

69.580/67 54.8 43.9 73.385/71 58.7 45.6 77.4

69.280/67 54.0 43.0 73.085/71 57.5 45.2 76.7

100

7.5 2.875/63 50.4 41.3

10 4.775/63 51.1 41.8

15 9.875/63 51.8 42.5

1.2

2.0

4.3

71.280/67 58.9 45.0 75.685/71 63.3 47.4 79.8

70.980/67 58.2 44.8 75.185/71 62.2 46.4 79.4

70.580/67 57.0 44.6 74.585/71 61.1 45.6 78.8

90

7.5 2.975/63 53.3 42.9

10 4.975/63 54.2 43.4

15 10.175/63 54.7 43.7

1.3

2.1

4.4

71.980/67 60.6 47.2 76.185/71 65.0 46.6 81.1

71.980/67 59.8 45.4 76.085/71 64.0 46.7 80.4

71.380/67 58.7 44.8 75.485/71 62.7 46.2 79.7

85

7.5 2.975/63 54.8 43.3

10 4.975/63 55.8 43.6

15 10.275/63 56.5 45.2

1.3

2.1

4.4

72.880/67 62.2 48.0 77.085/71 66.8 48.8 81.8

72.680/67 61.3 46.1 76.985/71 65.7 47.3 81.4

72.180/67 60.2 45.5 76.285/71 64.2 47.1 80.5

80

7.5 375/63 56.2 43.9

10 575/63 57.3 44.3

15 10.475/63 58.0 45.9

1.3

2.2

4.5

74.580/67 65.3 49.2 78.885/71 70.0 50.4 83.8

74.380/67 64.3 47.4 78.685/71 68.8 48.6 83.3

73.680/67 63.2 46.6 78.085/71 67.4 48.1 82.4

70

7.5 3.175/63 59.1 45.1

10 5.275/63 60.2 45.5

15 10.775/63 61.0 47.0

4.6

1.3

2.3

85.2

75.280/67 66.0 47.8 79.785/71 70.3 49.4 84.2

67.4 48.3 80.585/71

60

7.5 3.275/63 61.8 46.3

10 5.375/63 63.0 46.8

15 11.175/63 63.8 46.1

71.8 50.0

85/71 74.9 50.8 87.2

15 11.575/63 66.8 48.9 78.180/67 71.5 50.4 83.085/71 76.3 52.2 87.9

73.3 50.2 86.248.0 77.5

80/67 70.2 49.5 82.3

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

7.5 3.375/63 64.3 47.8

10 5.575/63 65.7

76.680/67 68.8 48.9 81.485/71

Cooling Performance Data Report

ES061

CAPACITY DATA All performance at CFM Unit Load: Full Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 17: ES Series Guide Specifications - HydroPump

Model:

Size:

1600

Unit

kWEER

2.53 22.82.53 24.42.53 26.12.42 24.22.42 25.92.41 27.82.31 25.72.30 27.72.29 29.82.83 19.52.82 20.92.82 22.52.73 20.52.71 22.22.70 23.82.62 21.72.60 23.42.59 25.33.15 16.73.14 18.03.12 19.43.05 17.53.03 19.03.01 20.52.95 18.42.92 20.02.89 21.63.51 14.33.48 15.43.46 16.63.40 15.03.37 16.23.34 17.53.30 15.63.26 17.03.23 18.53.70 13.23.67 14.33.64 15.43.59 13.83.55 15.03.52 16.23.48 14.43.44 15.73.40 17.03.90 12.13.87 13.23.84 14.23.79 12.73.75 13.83.72 15.03.69 13.23.64 14.43.60 15.74.36 10.24.32 11.14.28 12.14.25 10.74.20 11.64.15 12.64.14 11.14.08 12.24.02 13.24.88 8.64.84 9.34.79 10.14.77 8.94.71 9.74.65 10.64.66 9.24.60 10.14.53 11.0

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

57.680/67 45.1 37.0

ES Series Capacity Data

Pressure

Drop

(Psi)

2.0

3.5

7.2

2.0

3.3

6.965.4

80/67 61.0 43.3 69.685/71 65.4 44.5 74.0

64.980/67

57.980/67 45.8 37.3 60.985/71 49.2 38.7 64.2

58.180/67 46.5 37.4 61.385/71 49.9 38.9 64.5

60.785/71 48.4 38.4 63.9

110

9 3.975/63 42.0 35.7

12 6.675/63 42.6 35.8

18 13.775/63 43.1 36.0

1.7

2.9

5.9

59.280/67 49.6 38.6 62.785/71 53.2 40.1 66.2

58.980/67 48.8 38.3 62.485/71 52.3 39.8 65.8

58.680/67 48.1 38.0 62.085/71 51.6 39.3 65.4

100

9 475/63 44.6 36.7

12 6.875/63 45.3 37.0

18 14.175/63 45.9 37.3

1.7

3.0

6.1

60.680/67 52.6 39.7 64.485/71 56.4 41.2 68.1

60.380/67 51.8 39.4 63.985/71 55.6 40.8 67.6

59.980/67 50.9 39.2 63.485/71 54.6 40.4 67.1

90

9 4.275/63 47.3 37.9

12 775/63 48.1 38.2

18 14.575/63 48.8 38.4

1.8

3.0

6.3

61.480/67 54.0 40.4 65.285/71 57.9 41.8 69.1

61.080/67 53.2 40.0 64.885/71 57.0 41.4 68.5

60.680/67 52.4 39.7 64.385/71 56.0 41.1 67.9

85

9 4.275/63 48.7 38.4

12 7.175/63 49.4 38.7

18 14.775/63 50.2 39.0

1.8

3.1

6.4

62.380/67 55.4 41.0 66.185/71 59.6 42.2 70.1

61.980/67 54.6 40.7 65.585/71 58.5 42.0 69.4

61.480/67 53.7 40.3 65.085/71 57.5 41.6 68.8

80

9 4.375/63 50.0 39.0

12 7.275/63 50.9 39.2

18 1575/63 51.6 39.5

1.9

3.1

6.5

63.880/67 58.3 42.1 67.985/71 62.6 43.3 72.1

63.380/67 57.4 41.7 67.385/71 61.5 43.0 71.4

62.980/67 56.5 41.3 66.885/71 60.4 42.7 70.7

70

9 4.475/63 52.7 40.0

12 7.475/63 53.4 40.4

18 15.475/63 54.2 40.8

6.7

1.9

3.2

73.2

64.480/67 59.1 42.5 68.485/71 63.3 43.6 72.6

60.1 42.9 69.085/71

60

9 4.675/63 55.1 41.2

12 7.775/63 56.0 41.6

18 1675/63 56.8 42.0

64.3 44.1

85/71 67.1 45.0 75.2

18 16.575/63 59.3 43.0 67.080/67 63.7 44.3 71.485/71 68.2 45.6 75.9

66.0 44.6 74.442.6 66.5

80/67 62.7 43.9 70.8

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

9 4.775/63 57.6 42.2

12 875/63 58.5

66.080/67 61.7 43.5 70.185/71

Cooling Performance Data Report

ES071

CAPACITY DATA All performance at CFM Unit Load: Partial Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 18: ES Series Guide Specifications - HydroPump

Model:

Size:

2200

Unit

kWEER

4.21 18.14.27 19.14.34 20.04.05 19.24.10 20.24.16 21.23.87 20.43.92 21.63.97 22.74.54 16.24.60 17.04.67 17.84.38 17.04.43 18.04.49 18.94.22 18.04.26 19.14.31 20.14.90 14.34.96 15.15.02 15.94.74 15.14.79 16.04.85 16.84.62 15.84.64 16.84.68 17.85.29 12.75.35 13.45.41 14.15.13 13.35.18 14.15.23 14.94.99 13.95.03 14.85.07 15.75.50 11.95.56 12.65.62 13.35.35 12.55.39 13.25.44 14.05.20 13.05.24 13.95.27 14.75.72 11.25.78 11.85.85 12.55.56 11.75.61 12.45.66 13.15.51 11.95.46 12.95.51 13.76.20 9.76.26 10.36.33 10.96.05 10.16.09 10.86.13 11.45.97 10.45.90 11.35.98 12.06.75 8.46.81 8.96.88 9.46.60 8.86.64 9.36.68 9.96.50 9.06.47 9.76.58 10.2

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

78.880/67 60.9 49.8

ES Series Capacity Data

Pressure

Drop

(Psi)

2.0

3.5

7.2

2.0

3.3

6.989.9

80/67 81.3 58.0 95.485/71 86.7 59.5 101.1

89.180/67

79.380/67 62.0 50.2 83.785/71 66.2 52.1 88.1

79.580/67 62.8 50.7 84.085/71 67.4 51.6 89.0

83.185/71 65.0 51.5 87.5

110

9 3.975/63 56.9 48.0

12 6.675/63 57.8 48.5

18 13.775/63 58.4 48.8

1.7

2.9

5.9

81.780/67 66.8 52.2 86.185/71 71.5 54.0 91.1

81.280/67 65.7 51.8 85.685/71 70.2 53.5 90.3

80.680/67 64.6 51.2 85.185/71 69.0 52.8 89.7

100

9 475/63 60.4 49.4

12 6.875/63 61.4 49.8

18 14.175/63 62.2 49.7

1.7

3.0

6.1

83.980/67 70.7 53.6 88.685/71 75.7 55.0 93.8

83.080/67 69.4 53.2 87.885/71 74.1 54.9 92.7

82.580/67 68.1 52.7 87.085/71 72.8 54.2 92.0

90

9 4.275/63 63.8 50.9

12 775/63 64.8 51.5

18 14.575/63 65.8 50.5

1.8

3.0

6.3

84.780/67 72.6 54.4 89.885/71 77.5 56.1 94.9

84.280/67 71.3 53.8 89.085/71 76.2 55.4 94.1

83.380/67 70.0 53.2 88.285/71 74.5 55.0 93.0

85

9 4.275/63 65.4 51.7

12 7.175/63 66.7 52.0

18 14.775/63 67.6 52.6

1.8

3.1

6.4

85.780/67 74.3 55.1 90.985/71 79.5 56.6 96.3

85.180/67 73.0 54.6 90.085/71 77.9 56.2 95.1

84.480/67 71.7 53.9 89.285/71 76.4 55.5 94.2

80

9 4.375/63 67.1 52.2

12 7.275/63 68.3 52.8

18 1575/63 69.4 53.3

1.9

3.1

6.5

88.080/67 77.9 56.4 93.285/71 83.1 58.1 98.7

87.180/67 76.5 55.8 92.385/71 81.6 57.4 97.6

86.380/67 75.0 55.2 91.485/71 79.9 56.8 96.5

70

9 4.475/63 70.2 53.7

12 7.475/63 71.5 54.3

18 15.475/63 72.8 54.6

6.7

1.9

3.2

99.9

88.280/67 78.2 56.6 93.485/71 83.3 58.1 98.8

79.7 57.3 94.485/71

60

9 4.675/63 73.3 55.1

12 7.775/63 74.6 55.7

18 1675/63 76.0 56.3

85.0 58.8

85/71 88.3 60.0 102.2

18 16.575/63 79.1 57.6 91.980/67 84.5 59.3 97.585/71 90.1 60.7 103.3

86.6 59.3 101.057.0 91.1

80/67 82.9 58.6 96.5

Entering

Water

F

Water

flow

GPM

Pressure

Drop

Ft. Water

Cooling

Ent. Air

db/wb,F

Total

Btu/hr.

Sensible

Btu/hr.

Ht. Rej.

Btu/hr.

50

9 4.775/63 76.3 56.3

12 875/63 77.6

90.280/67 81.4 57.9 95.585/71

Cooling Performance Data Report

ES071

CAPACITY DATA All performance at CFM Unit Load: Full Load

COOLING

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 19: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

0.9

1.9

0.7

1.1

2.2

0.6

1.0

2.1

0.6

1.0

ES Series Capacity Data

Pressure

Drop

(Psi)

0.6

1.0

2.0

0.6

0.9

1.9

17.3 1.44 4.5

6

24.5 20.8 1.15

20.0 1.49 4.9

6

27.5 24.3 1.21 6.626.5 22.4 1.36 5.725.2 20.3 1.50

0.5

4.9

80

3

25.7 22.8 1.18 6.425.0 21.0 1.33 5.524.1 19.8 1.48 4.8

4

26.8 23.4 1.19 6.625.6 21.8 1.34 5.624.7

6.223.7 19.7 1.30 5.322.9 18.0 1.45 4.6

70

3

23.1 20.2 1.13 6.022.4 18.3 1.27 5.120.5 17.4 1.39 4.3

4

23.8 20.4 1.14 6.122.9 18.9 1.29 5.222.0

15.2 1.39 4.1

6

21.7 18.4 1.10 5.821.1 16.9 1.25 5.020.3 15.6 1.40 4.2

60

3

20.4 16.2 1.08 5.618.8 16.1 1.19 4.619.3 14.8 1.38 4.1

4

20.9 17.6 1.09 5.620.5 16.3 1.24 4.919.6

12.9 1.35 3.8

6

19.0 15.8 1.06 5.318.4 14.6 1.20 4.517.9 13.6 1.36 3.9

2.0

50

3

17.8 14.5 1.04 5.017.4 13.8 1.18 4.317.1 12.7 1.34 3.7

4

18.3 15.0 1.05 5.117.9 14.1 1.19 4.417.3

11.0 1.31 3.4

6

16.5 13.2 1.02 4.716.0 12.2 1.16 4.015.6 11.2 1.31 3.5

40

3

15.5 12.4 1.00 4.515.2 11.5 1.15 3.914.7 10.5 1.30 3.3

4

15.9 12.7 1.01 4.615.5 11.8 1.15 3.915.1

6

14.2 11.0 0.99 4.213.7 10.3 1.12 3.613.4 9.4 1.28 3.1

0.98 4.113.4 9.9 1.12 3.513.2 9.0 1.27 3.0

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

30

3

13.5 10.3 0.98 4.013.0 9.8 1.12 3.412.8 8.7 1.27 3.0

4

13.7 10.6

Heating Performance Data Report

ES025

CAPACITY DATA All performance at 600 Unit Load: Partial Load

HEATING

Pressure

Drop

Ft. Water

1.3

2.1

4.4

1.2

2.1

4.3

1.4

2.3

4.7

1.3

2.2

4.6

1.5

2.5

5.1

1.4

2.4

4.9

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 20: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

0.5

0.9

1.9

Pressure

Drop

(Psi)

0.7

1.1

2.2

0.6

1.0

2.1

0.6

6

35.0 28.7 1.90 5.434.0

ES Series Capacity Data

0.6

1.0

2.0

0.6

0.9

1.9

2.36 4.4

6

38.6 31.9 1.98 5.737.8 30.9 2.19 5.137.1 29.0 2.42 4.5

80

3

35.7 29.7 1.92 5.534.6 27.6 2.10 4.833.8 26.1 2.32 4.3

4

37.3 30.7 1.95 5.636.4 28.9 2.14 5.035.3

2.09 4.833.3 25.6 2.30 4.2

70

3

32.3 25.9 1.84 5.129.2 22.5 1.97 4.330.5 23.1 2.23 4.0

4

33.3 27.2

2.27

1.86 5.232.1 25.7 2.05 4.631.8

2.17 3.9

4.1

6

31.2 25.2 1.82 5.030.4 23.9 2.00 4.429.8 22.4 2.21 4.0

60

3

28.5 22.6 1.76 4.728.0 21.5 1.94 4.227.5 20.4 2.14 3.8

4

29.8 23.8 1.79 4.929.1 22.7 1.97 4.328.6

2.09 3.6

6

27.6 22.0 1.74 4.627.0 20.7 1.92 4.126.5 19.4 2.11 3.7

2.0

1.050

3

25.4 19.8 1.70 4.425.1 18.8 1.87 3.924.6 17.7 2.06 3.5

4

26.4 20.8 1.72 4.525.9 19.7 1.89 4.025.5

2.02 3.2

6

24.3 18.9 1.68 4.223.8 17.7 1.84 3.823.2 16.6 2.04 3.3

40

3

22.4 17.2 1.64 4.022.0 16.1 1.81 3.621.7 15.2 2.00 3.2

4

23.4 18.0 1.66 4.123.0 16.9 1.82 3.722.4

6

21.3 16.0 1.61 3.920.8 14.9 1.78 3.420.4 13.9 1.97 3.0

5.1

3.02.5

1.58 3.719.5 13.7 1.75 3.319.3 12.8 1.95 2.9

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

3

19.8 14.7

4

20.5 15.3 1.60 3.820.1 14.3 1.77 3.319.8 13.3 1.96

Heating Performance Data Report

ES025

CAPACITY DATA All performance at 900 Unit Load: Full Load

HEATING

1.5

15.8

18.5

21.3

24.3

27.4

1.3

2.1

4.4

1.2

2.1

4.3

1.4

2.3

4.7

1.3

2.2

4.6

1.4

2.4

4.9

27.5

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 21: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

9

36.1 30.4 1.75 6.0

ES Series Capacity Data

1.2

2.0

4.1

1.1

1.9

3.9

Pressure

Drop

(Psi)

1.3

2.2

4.5

1.3

2.1

4.4

2.26 4.8

9

40.9 35.2 1.84 6.539.8 33.1 2.05 5.738.8 31.1 2.29 5.0

1.8

3.8

80

4.5

37.7 31.9 1.78 6.236.9 30.2 1.99 5.436.1 28.5 2.24 4.7

6

39.3 33.4 1.81 6.438.3 31.6 2.02 5.637.4

1.97 5.234.2 26.9 2.21 4.5

70

4.5

33.5 27.9 1.71 5.732.6 26.3 1.92 5.032.0 24.8 2.15 4.4

6

34.7

2.18 4.4

1.73 5.933.8 27.4 1.95 5.133.0

2.08 4.1

9

31.5 26.0 1.67 5.530.7 24.5 1.87 4.829.9 23.0 2.10 4.2

60

4.5

29.3 24.0 1.63 5.328.6 22.6 1.83 4.628.1 21.3 2.06 4.0

6

30.3 25.0 1.65 5.429.6 23.5 1.85 4.729.0

1.98 3.7

9

27.2 22.0 1.58 5.026.5 20.6 1.78 4.425.9 19.3 2.00 3.8

4.2

2.050

4.5

25.4 20.3 1.55 4.824.8 19.1 1.75 4.224.4 17.8 1.97 3.6

6

26.2 21.1 1.57 4.925.6 19.8 1.76 4.325.1

1.90 3.3

9

23.1 18.2 1.51 4.522.5 17.0 1.70 3.922.0 15.7 1.92 3.4

40

4.5

21.7 16.9 1.49 4.321.2 15.8 1.68 3.720.8 14.7 1.89 3.2

6

22.4 17.5 1.50 4.421.9 16.3 1.69 3.821.4

9

19.4 14.7 1.45 3.918.9 13.6 1.64 3.418.4 12.5 1.85 2.9

10.4

2.95

1.44 3.717.9 12.7 1.62 3.217.6 11.7 1.83 2.8

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

4.5

18.3 13.7

6

18.8 14.2 1.44 3.818.4 13.1 1.63 3.318.0 12.0 1.84

Heating Performance Data Report

ES035

CAPACITY DATA All performance at 1050 Unit Load: Partial Load

HEATING

8.8

2.8

4.7

9.7

2.7

4.5

9.4

2.9

4.9

10.1

3

15.2

18.5

22.1

25.8

29.8

2.6

4.4

9.1

2.5

4.2

29.0

35.2 28.6

1.2

1.1

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 22: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

9

48.5 39.8 2.66 5.4

ES Series Capacity Data

1.2

2.0

4.1

1.1

1.9

3.9

Pressure

Drop

(Psi)

1.3

2.2

4.5

1.3

2.1

4.4

3.24 4.5

9

54.3 45.2 2.78 5.752.9 43.0 3.03 5.151.6 40.8 3.30 4.6

1.8

3.8

80

4.5

49.5 40.8 2.68 5.448.5 38.9 2.92 4.947.6 37.0 3.19 4.4

6

51.7 42.8 2.73 5.650.6 40.8 2.97 5.049.5

2.89 4.846.2 35.8 3.16 4.3

70

4.5

44.4 36.0 2.57 5.143.4 34.4 2.81 4.542.7 32.5 3.08 4.1

6

46.3

3.12 4.2

2.61 5.245.3 36.0 2.85 4.744.4

3.02 3.8

9

42.9 34.7 2.55 4.942.0 32.8 2.78 4.441.0 30.9 3.05 3.9

60

4.5

39.6 31.4 2.48 4.738.8 29.8 2.72 4.238.1 28.2 2.99 3.7

6

41.1 33.0 2.51 4.840.3 31.3 2.75 4.339.5

2.90 3.5

9

37.7 29.7 2.45 4.536.9 28.1 2.69 4.036.0 26.4 2.94 3.6

4.2

2.050

4.5

35.0 27.1 2.40 4.334.3 25.7 2.63 3.833.6 24.3 2.87 3.4

6

36.3 28.4 2.42 4.435.5 26.8 2.65 3.934.7

2.79 3.2

9

32.9 25.3 2.35 4.132.2 23.8 2.58 3.731.5 22.3 2.82 3.3

40

4.5

30.7 23.2 2.31 3.930.2 21.9 2.53 3.529.7 20.6 2.77 3.1

6

31.8 24.2 2.33 4.031.1 22.8 2.55 3.630.6

9

28.5 21.2 2.27 3.727.9 19.8 2.48 3.327.3 18.5 2.71 3.0

10.4

2.95

2.24 3.526.3 18.4 2.45 3.125.7 17.1 2.68 2.8

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

4.5

26.7 19.6

6

27.6 20.3 2.25 3.627.0 19.1 2.47 3.226.4 17.8 2.70

Heating Performance Data Report

ES035

CAPACITY DATA All performance at 1225 Unit Load: Full Load

HEATING

8.8

2.8

4.7

9.7

2.7

4.5

9.4

2.9

4.9

10.1

3

21.4

25.3

29.5

34.1

38.8

2.6

4.4

9.1

2.5

4.2

37.8

47.3 37.9

1.2

1.1

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 23: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

12

44.7 37.5 2.17 6.0

ES Series Capacity Data

1.3

2.3

4.7

1.3

2.2

4.6

Pressure

Drop

(Psi)

1.5

2.5

5.3

1.5

2.4

5.1

2.71 4.9

12

49.4 42.3 2.14 6.848.0 40.0 2.41 5.846.7 37.7 2.70 5.1

2.1

4.4

80

6

46.0 38.9 2.17 6.244.9 36.9 2.43 5.443.9 35.0 2.72 4.7

8

47.6 40.5 2.16 6.546.4 38.4 2.42 5.645.4

2.43 5.242.4 33.3 2.72 4.6

70

6

41.7 34.5 2.18 5.640.8 32.7 2.43 4.940.0 30.7 2.72 4.3

8

43.1

2.72 4.4

2.18 5.842.1 34.0 2.43 5.141.1

2.71 4.0

12

40.1 32.9 2.18 5.439.0 30.9 2.43 4.737.9 29.0 2.71 4.1

60

6

37.5 30.3 2.17 5.136.7 28.6 2.42 4.436.0 26.8 2.71 3.9

8

38.7 31.5 2.17 5.237.8 29.7 2.42 4.637.0

2.68 3.6

12

35.6 28.5 2.16 4.834.6 26.7 2.41 4.233.8 24.8 2.70 3.7

4.9

2.350

6

33.5 26.4 2.14 4.632.7 24.8 2.39 4.032.1 23.0 2.67 3.5

8

34.5 27.4 2.15 4.733.6 25.6 2.40 4.132.9

2.62 3.3

12

31.5 24.5 2.12 4.430.5 22.9 2.36 3.829.7 21.1 2.63 3.3

40

6

29.8 22.8 2.10 4.229.0 21.3 2.34 3.628.4 19.7 2.61 3.2

8

30.6 23.6 2.11 4.229.8 22.0 2.35 3.729.1

12

27.7 21.0 2.08 3.926.8 19.3 2.31 3.426.1 17.5 2.57 3.0

12.1

2.95.8

2.06 3.825.7 18.1 2.29 3.325.1 16.5 2.55 2.9

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

6

26.4 19.6

8

27.1 20.2 2.07 3.826.1 18.7 2.30 3.325.7 17.0 2.56

Heating Performance Data Report

ES049

CAPACITY DATA All performance at 1100 Unit Load: Partial Load

HEATING

10.2

3.2

5.4

11.3

3.1

5.2

10.9

3.4

5.6

11.7

3.5

20.4

23.9

27.8

32.0

36.3

3

5.1

10.5

2.9

4.9

35.9

43.5 35.4

1.4

1.3

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 24: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

12

60.9 49.6 3.52 5.1

ES Series Capacity Data

1.3

2.3

4.7

1.3

2.2

4.6

Pressure

Drop

(Psi)

1.5

2.5

5.3

1.5

2.4

5.1

4.17 4.3

12

67.7 56.0 3.65 5.466.2 53.5 3.92 4.964.8 50.9 4.24 4.5

2.1

4.4

80

6

60.8 49.4 3.52 5.159.5 46.8 3.79 4.658.6 45.2 4.10 4.2

8

64.0 51.8 3.58 5.262.6 50.2 3.86 4.861.5

3.79 4.658.8 44.7 4.10 4.2

70

6

54.6 43.4 3.41 4.754.1 41.7 3.67 4.353.2 40.1 3.98 3.9

8

57.6

4.03 4.0

3.46 4.956.6 44.4 3.73 4.455.7

3.90 3.8

12

54.4 43.4 3.40 4.753.6 41.0 3.66 4.352.4 38.8 3.96 3.9

60

6

49.2 38.5 3.29 4.448.5 36.8 3.56 4.047.9 35.2 3.85 3.6

8

51.6 40.8 3.34 4.550.9 39.0 3.61 4.150.0

3.77 3.5

12

48.3 37.6 3.28 4.347.7 35.7 3.53 4.046.6 34.0 3.82 3.6

4.9

2.350

6

44.1 33.4 3.18 4.143.3 32.0 3.44 3.742.8 30.5 3.73 3.4

8

45.9 35.3 3.23 4.245.2 33.7 3.48 3.844.6

3.65 3.2

12

42.6 32.0 3.15 4.041.8 30.6 3.41 3.641.3 29.0 3.69 3.3

40

6

39.0 28.9 3.07 3.738.6 27.5 3.33 3.438.1 26.1 3.62 3.1

8

40.7 30.2 3.11 3.840.1 28.7 3.37 3.539.6

12

37.3 27.3 3.03 3.636.8 26.0 3.29 3.336.3 24.5 3.57 3.0

12.1

2.95.8

2.96 3.434.1 23.4 3.22 3.133.8 22.1 3.50 2.8

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

6

34.5 24.7

8

35.8 26.0 2.99 3.535.4 24.5 3.25 3.235.0 23.2 3.53

Heating Performance Data Report

ES049

CAPACITY DATA All performance at 1700 Unit Load: Full Load

HEATING

10.2

3.2

5.4

11.3

3.1

5.2

10.9

3.4

5.6

11.7

3.5

27.2

31.9

37.1

42.1

47.8

3

5.1

10.5

2.9

4.9

46.5

59.7 47.2

1.4

1.3

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 25: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

15

62.1 52.2 2.99 6.1

ES Series Capacity Data

1.4

2.4

5.0

1.4

2.3

4.8

Pressure

Drop

(Psi)

1.6

2.7

5.6

1.5

2.6

5.3

3.81 4.9

15

69.4 59.2 3.05 6.767.8 56.3 3.41 5.866.5 53.4 3.83 5.1

2.3

4.6

80

7.5

64.0 54.1 3.00 6.262.9 51.7 3.37 5.562.0 49.3 3.80 4.8

10

66.5 56.5 3.02 6.465.2 54.0 3.39 5.664.1

3.36 5.359.7 47.1 3.78 4.6

70

7.5

57.5 47.8 2.96 5.756.6 45.6 3.33 5.055.9 43.4 3.75 4.4

10

59.6

3.77 4.5

2.97 5.958.6 47.5 3.34 5.157.7

3.73 4.1

15

55.3 45.4 2.94 5.554.3 43.1 3.32 4.853.3 40.9 3.74 4.2

60

7.5

51.3 41.7 2.92 5.150.6 39.7 3.30 4.550.1 37.8 3.72 3.9

10

53.1 43.5 2.93 5.352.3 41.4 3.31 4.651.7

3.71 3.6

15

48.8 39.1 2.91 4.948.0 37.0 3.28 4.347.3 35.0 3.71 3.7

5.2

2.550

7.5

45.5 36.0 2.89 4.645.0 34.2 3.27 4.044.6 32.4 3.71 3.5

10

47.0 37.4 2.90 4.846.4 35.6 3.28 4.246.0

3.72 3.2

15

42.8 33.2 2.88 4.442.2 31.3 3.27 3.841.7 29.4 3.72 3.3

40

7.5

40.1 30.7 2.87 4.139.8 29.0 3.27 3.639.6 27.4 3.71 3.1

10

41.3 31.9 2.88 4.240.9 30.1 3.27 3.740.6

15

37.2 27.9 2.86 3.836.9 26.2 3.25 3.336.7 24.5 3.69 2.9

12.8

2.86.2

2.85 3.635.1 24.5 3.24 3.235.0 22.9 3.69 2.8

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

7.5

35.3 26.0

10

36.2 26.9 2.85 3.735.9 25.3 3.25 3.235.8 23.7 3.69

Heating Performance Data Report

ES061

CAPACITY DATA All performance at 1500 Unit Load: Partial Load

HEATING

10.7

3.4

5.7

11.9

3.3

5.5

11.5

3.5

5.9

12.3

3.7

28.3

33.6

39.3

45.2

51.4

3.2

5.3

11.1

3.1

5.2

49.9

60.8 49.7

1.5

1.3

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 26: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

15

85.3 68.3 5.00 5.0

ES Series Capacity Data

1.4

2.4

5.0

1.4

2.3

4.8

Pressure

Drop

(Psi)

1.6

2.7

5.6

1.5

2.6

5.3

6.11 4.2

15

95.3 77.4 5.27 5.393.4 73.7 5.73 4.891.7 70.0 6.24 4.3

2.3

4.6

80

7.5

86.2 69.4 5.03 5.084.9 66.6 5.49 4.583.6 63.5 5.99 4.1

10

90.5 73.4 5.14 5.288.9 70.3 5.60 4.687.4

5.45 4.582.2 61.8 5.94 4.1

70

7.5

77.3 61.3 4.81 4.776.4 58.9 5.25 4.375.4 56.3 5.74 3.8

10

81.1

5.84 3.9

4.90 4.879.8 62.1 5.35 4.478.6

5.58 3.7

15

75.8 59.6 4.77 4.774.4 56.7 5.20 4.273.0 54.0 5.67 3.8

60

7.5

69.2 53.8 4.61 4.468.3 51.5 5.04 4.067.5 49.1 5.51 3.6

10

72.2 56.6 4.68 4.571.0 54.0 5.11 4.170.0

5.36 3.4

15

66.9 51.4 4.56 4.365.7 48.9 4.98 3.964.5 46.4 5.43 3.5

5.2

2.550

7.5

61.2 46.5 4.43 4.060.5 44.3 4.85 3.759.8 42.1 5.30 3.3

10

63.9 48.9 4.49 4.262.9 46.5 4.91 3.862.0

5.16 3.1

15

58.7 43.8 4.37 3.957.7 41.4 4.77 3.556.8 39.1 5.21 3.2

40

7.5

54.3 39.9 4.27 3.753.6 37.9 4.68 3.452.8 35.9 5.11 3.0

10

56.3 41.8 4.32 3.855.5 39.6 4.72 3.454.8

15

51.3 37.0 4.20 3.650.5 34.9 4.60 3.249.4 32.8 5.03 2.9

12.8

2.86.2

4.13 3.447.3 32.1 4.52 3.146.5 30.1 4.97 2.7

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

7.5

47.6 34.0

10

49.4 35.4 4.16 3.548.8 33.4 4.56 3.147.9 31.4 5.00

Heating Performance Data Report

ES061

CAPACITY DATA All performance at 2000 Unit Load: Full Load

HEATING

10.7

3.4

5.7

11.9

3.3

5.5

11.5

3.5

5.9

12.3

3.7

37.4

44.1

51.3

59.2

67.2

3.2

5.3

11.1

3.1

5.2

64.7

83.7 65.0

1.5

1.3

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 27: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

18

69.8 57.4 3.75 5.5

ES Series Capacity Data

2.0

3.5

7.2

2.0

3.3

6.9

Pressure

Drop

(Psi)

2.3

3.9

8.0

2.2

3.7

7.7

4.65 4.5

18

77.8 65.1 3.82 6.075.9 61.9 4.22 5.374.2 58.6 4.67 4.7

3.2

6.7

80

9

72.4 59.9 3.77 5.670.7 57.3 4.18 5.069.8 54.3 4.63 4.4

12

74.9 62.4 3.79 5.873.3 59.4 4.20 5.171.9

4.15 4.866.8 51.4 4.61 4.2

70

9

65.1 52.9 3.71 5.164.0 50.3 4.12 4.663.1 47.8 4.58 4.0

12

67.3

4.59 4.1

3.73 5.366.0 52.3 4.14 4.764.9

4.54 3.8

18

62.1 49.9 3.69 4.960.9 47.2 4.09 4.459.8 44.6 4.55 3.8

60

9

58.2 46.1 3.66 4.757.3 43.8 4.07 4.156.7 41.4 4.54 3.7

12

60.0 47.9 3.67 4.859.0 45.4 4.08 4.258.2

4.53 3.4

18

54.9 42.8 3.63 4.453.9 40.4 4.05 3.953.2 38.0 4.53 3.4

7.4

3.650

9

51.6 39.6 3.61 4.251.0 37.5 4.04 3.750.4 35.4 4.52 3.3

12

53.1 41.1 3.62 4.352.4 38.9 4.04 3.851.8

4.47 3.0

18

48.1 36.3 3.58 3.947.4 34.1 4.01 3.546.8 31.9 4.48 3.1

40

9

45.5 33.7 3.55 3.845.2 31.8 3.99 3.344.8 29.9 4.46 2.9

12

46.7 35.0 3.57 3.846.1 33.0 4.00 3.445.6

18

42.0 30.4 3.52 3.541.5 28.4 3.95 3.141.3 26.5 4.43 2.7

18.4

2.78.9

3.51 3.339.7 26.7 3.94 3.039.7 24.9 4.41 2.6

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

9

39.9 28.5

12

40.9 29.4 3.51 3.440.5 27.6 3.94 3.040.6 25.6 4.42

Heating Performance Data Report

ES071

CAPACITY DATA All performance at 1600 Unit Load: Partial Load

HEATING

15.4

4.9

8.3

17.1

4.7

8

16.5

5.1

8.5

17.7

5.3

31.0

36.6

43.0

49.6

56.4

4.6

7.7

16

4.4

7.4

55.0

68.2 54.4

2.1

1.9

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014

Page 28: ES Series Guide Specifications - HydroPump

Model:

Size:

CFM

Ent. Air

F

607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080607080

Due to variations in installation, actual performance may vary from the tabulated data. Performance contained herin are as a result of extensive testing and are not express warranties between the parties and may be changed at any time.

18

91.0 72.8 5.37 5.0

ES Series Capacity Data

2.0

3.5

7.2

2.0

3.3

6.9

Pressure

Drop

(Psi)

2.3

3.9

8.0

2.2

3.7

7.7

6.40 4.3

18

101.3 82.3 5.62 5.398.9 78.2 6.04 4.897.0 74.5 6.51 4.4

3.2

6.7

80

9

92.8 74.9 5.41 5.091.1 71.6 5.84 4.689.4 68.3 6.30 4.2

12

97.0 78.9 5.51 5.294.9 75.4 5.94 4.793.0

5.79 4.587.3 65.9 6.24 4.1

70

9

83.8 66.6 5.21 4.782.3 63.7 5.63 4.380.8 60.5 6.07 3.9

12

86.7

6.14 4.0

5.28 4.884.9 66.2 5.70 4.483.2

5.92 3.7

18

81.2 63.7 5.15 4.679.4 60.6 5.56 4.277.8 57.8 6.00 3.8

60

9

75.2 58.2 5.02 4.474.0 55.4 5.42 4.072.9 52.6 5.86 3.6

12

78.0 61.4 5.08 4.576.5 58.6 5.49 4.175.3

5.72 3.4

18

71.9 55.2 4.95 4.370.5 52.7 5.35 3.969.2 49.8 5.77 3.5

7.4

3.650

9

66.9 50.9 4.84 4.065.8 48.5 5.24 3.764.8 45.8 5.66 3.4

12

69.3 53.3 4.90 4.168.2 50.2 5.29 3.867.1

5.52 3.1

18

63.5 47.2 4.77 3.962.3 44.6 5.16 3.561.1 42.3 5.57 3.2

40

9

59.2 43.7 4.68 3.758.6 41.4 5.07 3.457.7 39.3 5.48 3.1

12

61.2 45.4 4.72 3.860.1 43.1 5.11 3.459.3

18

55.8 40.1 4.60 3.654.7 37.9 4.98 3.253.8 35.7 5.40 2.9

18.4

2.98.9

4.52 3.451.8 35.4 4.91 3.151.2 33.3 5.33 2.8

Heating

Entering

Water, F

Water

flow, GPM

Total

Btu/hr.

Ht. Abs.

Btu/hr.

Unit

kWCOP

Pressure

Drop

Ft. Water

30

9

52.5 37.5

12

54.0 38.8 4.56 3.553.2 36.7 4.95 3.252.5 34.4 5.36

Heating Performance Data Report

ES071

CAPACITY DATA All performance at 2200 Unit Load: Full Load

HEATING

15.4

4.9

8.3

17.1

4.7

8

16.5

5.1

8.5

17.7

5.3

40.8

47.6

55.0

62.9

71.9

4.6

7.7

16

4.4

7.4

69.3

89.0 69.2

2.1

1.9

As a result of continuing research and development, specifications are subject to change without notice.

GeoMaster, LLC 3512 Cavalier Dr.

Fort Wayne, IN 46808 Phone: 877-443-6411

http://www.GeoExcel.com 03/2014