ep series ups
TRANSCRIPT
![Page 1: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/1.jpg)
GE Power Quality
EP Series UPS
![Page 2: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/2.jpg)
GE C&I PWQ AsiaSep., 2006 2
1. Market intelligence
2. Power Model
3. Features
4. Cabinet views
5. Technical description
6. Battery management
7. Communication
Content
![Page 3: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/3.jpg)
GE C&I PWQ AsiaSep., 2006 3
Pluggable market
kVA CAGR< 1 4.8%1 - 5 8.4%
5.1 - 20 9.6%21 - 100 9.9%101 - 250 8.5%251 - 1000 6.3%
> 1000 3.7%
2006: $5.1B
<5kVA = 52% of global market
Total <20kVA equals 68% of global market
< 1kVA18%
>200 kVA13%
1-5 kVA34%
5.1-20 kVA16%
21-50 kVA9%
50-200 kVA10%
15%
33%18%
16%
10% 6% 2% <1kVA
1 - 5kVA
5 - 20kVA
20 - 100kVA
100 - 250kVA
250 - 1000kVA
>1000kVA
China
•Dominated by China made
•APC – made in Suzhou
•Local brands – Santak, Delta, Powercom etc
•Clones – illegal copies
Rest of Asia
•International brands – China or Taiwan sourced
•APC – own manufacturing
•MGE, Liebert, Powerware – OEM or ODM with Santak, Delta or Powercom
AsiaGlobal
2006: $1.4B
![Page 4: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/4.jpg)
GE C&I PWQ AsiaSep., 2006 4
EP series family
Tower ModelStandard Model
• Range: 700VA, 1000VA, 2000VA, 3000VA, 6000VA
• With internal battery providing 5~7 mins back time
Long runtime model
• Range: 700VA, 1000VA, 2000VA, 3000VA, 6000VA
• Without internal battery
• With high capacity internal battery chargerRack Model
Standard Model (Only)
• Range: 700VA, 1000VA, 2000VA, 3000VA, 6000VA
• With internal battery providing 5~7 mins back time
• Battery is in additional cabinet for 2000/3000/6000VA
![Page 5: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/5.jpg)
GE C&I PWQ AsiaSep., 2006 5
Feature
General
• Double conversion, on line (VFI)
• LED display – overload, on-line & battery status
• Full digital microprocessor controlled
• Programmable computer shutdown
• Lightning and transient surge protection
• Automatic bypass switch
• Battery Start (cold start)
Performance
• Input Power Factor: 0.97/0.98
• Wide input voltage window (115~300Vac/0.7~3K, 176~276Vac/6KVA)
• Frequency (50/60HZ), Voltage (220/230/240), auto sensing
Battery
• Programmable automatic test
• Protection against deep discharge
• Extended runtime available and auto-recognition
Communication
• RS232, USB
• SNMP
![Page 6: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/6.jpg)
GE C&I PWQ AsiaSep., 2006 6
Cabinet view
700/1000VA
Front Panel
2000/3000VA
6000VA
700/1000VA (2U)
2000/3000VA (2U)
6000VA (3U)
![Page 7: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/7.jpg)
GE C&I PWQ AsiaSep., 2006 7
Cabinet view Rear Panel (Tower)
![Page 8: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/8.jpg)
GE C&I PWQ AsiaSep., 2006 8
Cabinet view Rear Panel (Tower)
![Page 9: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/9.jpg)
GE C&I PWQ AsiaSep., 2006 9
Cabinet view Rear Panel (Rack)
![Page 10: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/10.jpg)
GE C&I PWQ AsiaSep., 2006 10
Block Diagram
700/1000VA
2000/3000VA
6000VA
![Page 11: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/11.jpg)
GE C&I PWQ AsiaSep., 2006 11
Battery
Model EP 700 T/R EP 1000 T/R EP 2000 T/R EP 3000 T/R EP 6000 T/R
Num. & Model
3x12V
7.2Ah
3x12V
7.2Ah
3x12V
7.2Ah
3x12V
7.2Ah
3x12V
7.2Ah
Model 100% Load
50% Load
EP 700 T/R 5 mins 10 mins
EP 1000 T/R
5 mins 10 mins
EP 2000 T/R
5 mins 10 mins
EP 3000 T/R
5 mins 10 mins
EP 6000 T/R
7 mins 14 mins
Standard Model
Tower & Rack
Long Runtime Tower Model
Model EP 700 LRT EP 1000 LRT
EP 2000 LRT
EP 3000 LRT
EP 6000 LRT
Charging Current (max)
7A 8A 9.6A 9.6A 4.3A
![Page 12: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/12.jpg)
GE C&I PWQ AsiaSep., 2006 12
Communication
Connection
• RS232, USB
• LAN (SNMP)
• Internet
![Page 13: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/13.jpg)
GE C&I PWQ AsiaSep., 2006 13
Communication
![Page 14: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/14.jpg)
GE C&I PWQ AsiaSep., 2006 14
Package
• Olympics• Product pictures• Key features• Back panel labeling
Listing all connectivity and electrical connections
• Internal CD packaging for software connectivity.
Box Labeling
![Page 15: EP Series UPS](https://reader033.vdocuments.mx/reader033/viewer/2022061107/544ccdcbb1af9f310b8b4a3f/html5/thumbnails/15.jpg)
GE C&I PWQ AsiaSep., 2006 15
Q&A