eod portable x-ray enhancements using dual energy imaging

64
EOD Portable X-ray Enhancements using Dual Energy Imaging

Upload: others

Post on 04-Jan-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EOD Portable X-ray Enhancements using Dual Energy Imaging

EOD Portable X-ray Enhancements using Dual Energy Imaging

Page 2: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 2

What are we using now?

Page 3: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 3

Grey Scale Imaging

Limited to no x-ray

energy

effected by the material

High amount of x-ray

energy

effected by the material

Grey scale color ranges will vary based on

amount of x-ray energy used. More energy =

lighter color

Lower density or lower

thickness of the

material

Higher density or

higher thickness of the

material

Page 4: EOD Portable X-ray Enhancements using Dual Energy Imaging

• Standard EOD method of

viewing images

• Provides visual SHAPE

recognition capability

• Single energy x-ray

measurement

• Darker the item the more

dense the item

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 4

Grey Scale Imaging

Page 5: EOD Portable X-ray Enhancements using Dual Energy Imaging

The ONLY information that grey scale imaging provides to the bomb

technician is the ability to identify shapes

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 5

Grey Scale Imaging

Page 6: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 6

What are the drawbacks of single energy imaging for EOD?

Page 7: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 7

Drawbacks (Inaccurate Examples)

Page 8: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 8

Hypothetical Scenario: Airport security screening bags at a

checkpoint think they have found a bomb. Who do they call?

Page 9: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 9

Real x-ray interpretation problem

Page 10: EOD Portable X-ray Enhancements using Dual Energy Imaging

• Where is the IED?

• Where is each IED

component?

• How would I render this

safe?

• Where is the explosive and

detonator?

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 10

Can you solve this problem?

Page 11: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 11

Can you solve this problem?

Grey Scale works great Grey Scale not so great

Page 12: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 12

So why is EOD still just using single energy imaging?

Page 13: EOD Portable X-ray Enhancements using Dual Energy Imaging

Do they know

something that EOD

does not know?

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 13

Why are airports not using grey scale?

Page 14: EOD Portable X-ray Enhancements using Dual Energy Imaging

Aviation Security has done study after study after study on an X-ray operators ability to identify threats with greyscale vs dual energy imaging.

What could EOD find out if they would do the same?

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 14

Why are airports not using grey scale?

Page 15: EOD Portable X-ray Enhancements using Dual Energy Imaging

Conclusion

From the survey results, color has been shown superior to grey scale for effectiveinformation processing time and for memory performance. The ability to detect and identify details from the image is inherently increased by using color.

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 15

Why are airports not using grey scale?

https://pdfs.semanticscholar.org/e778/b621e2175398d84726cc72884abbb7944722.pdf

Page 16: EOD Portable X-ray Enhancements using Dual Energy Imaging

IED detection performance was best whenimages were displayed without imageenhancements. Performance decreasedwhen images were presented in grey scale.

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 16

Why are airports not using grey scale?

https://www.researchgate.net/publication/238393928_X-ray_Imagery_Enhancing_the_Value_of_the_Pixels

Page 17: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 17

But we have always done it this way …

Page 18: EOD Portable X-ray Enhancements using Dual Energy Imaging

Many EOD and portable X-ray manufacturers still think thatdual energy imaging is a gimmick and don‘t understandhow it can be an enhancementover grey scale.

It is also not easy to do withpulsed generators and somemanufacturers cannot do it.

No studies, no understanding, no drive for change.

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 18

I live in a bubble …

Page 19: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 19

Dual Energy Imaging with EOD Portable Systems

Page 20: EOD Portable X-ray Enhancements using Dual Energy Imaging

EOD x-ray systems with the required penetration capability (pulsed generators) requirea dual energy (DE) module on the x-ray generator to create dual energy images

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 20

Dual Energy Imaging

Dual Energy

Module

Provides a measurement of the

average effective atomic number of

the material x-rayed

A dual energy

measurement is

known as

“Material Discrimination”

Page 21: EOD Portable X-ray Enhancements using Dual Energy Imaging

EOD x-ray systems with the required penetration capability (pulsed generators) requirea dual energy (DE) module on the x-ray generator to create dual energy images

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 21

Dual Energy Imaging

0 -10= Orange11-15= Green15-30= Blue

Page 22: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 22

What are the advantages of Dual Energy Imaging?

Page 23: EOD Portable X-ray Enhancements using Dual Energy Imaging

In the absence of a

recognizable shape material

discrimination tells what the

item is made out of based on

its average atomic number

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 23

Material Discrimination

Page 24: EOD Portable X-ray Enhancements using Dual Energy Imaging

In the absence of a recognizable shape material discrimination tells what the items is made out of based on its average atomic number

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 24

Material Discrimination

Page 25: EOD Portable X-ray Enhancements using Dual Energy Imaging

In grey scale just because something is dark does not verify it is a metal nor can grey scale verify organic materials

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 25

Material Discrimination

Most explosives are organic and MUST be located before doing a disruption on the package

Page 26: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 26

No bleed out from high pulses

Page 27: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 27

Material Discrimination no bleed out

Bleed out occurs when you are using higher pulses on low density or thin materials. Dual energy imaging negates this problem

Page 28: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 28

Material Discrimination no bleed out

This is extremely important when you consider that explosives would bleed out at higher pulses.

Page 29: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 29

Metal Detection

Page 30: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 30

Identification of „Metals“

Just because it is dark in grey scale does not mean it is a metal

Page 31: EOD Portable X-ray Enhancements using Dual Energy Imaging

The majority of IED

components are made from

metal so being able to

highlight metals is a huge

benefit over grey scale

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 31

„Metals“ IED Power Sources

Page 32: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 32

Identification of „Metals“ IED switches

This allows you the ability to locate IED circuits in a cluttered image more accurately and or verify a item that is at a difficult angle as being made from metal

Page 33: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 33

Identification of „Metals“ IED switches

Page 34: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 34

Detonators and Initiators

Page 35: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 35

Identification of IED Dets (Grey Scale)

Page 36: EOD Portable X-ray Enhancements using Dual Energy Imaging

What information does

grey scale provide vs dual

energy when you look at

detonators and initiators?

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 36

Identification of IED Dets

Page 37: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 37

Identification of „Metals“ IED Dets

Page 38: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 38

Pipe Bombs

Page 39: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 39

Identification of Pipe Bombs

What kind of pipe?

Is it filled or empty?

What kind of explosive?

Low pulse Image without

enhancementEnhanced

image

Page 40: EOD Portable X-ray Enhancements using Dual Energy Imaging

Dual Energy tells me:

• One pipe is metal

• One pipe is PVC (Green outside)

• The PVC pipe is filled with a

Smokeless powder (orange color

inside of the pipe)

• Grey scale CANNOT provide this

information

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 40

Identification of Pipe Bombs

Page 41: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 41

Identification of Pipe Bombs

Page 42: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 42

Identification of Pipe Bombs (Peeling)

Page 43: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 43

Explosives

Page 44: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 44

Identification of Explosives

Page 45: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 45

Identification of Explosives

Comp B

7.2 Z eff

1.71

g/cc

TNT

Flake

7.1 Z eff

1.51 g/cc

Emulsio

n

9.2 Z eff

1.37 g/cc

Emulsio

n

8.3 Z eff

1.32 g/cc

CAST

TNT

7.1 Z eff

1.51 g/cc

Tritanol

9.1 Z eff

1.65

g/cc

Emulsio

n

9.8 Z eff

1.44 g/cc

C-4

7.1 Z eff

1.58

g/cc

SEMTE

X

7.2 Z eff

1.47

g/cc

COMP B

7.2 Z eff

1.71

g/cc

Page 46: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 46

Identification of Explosives

Comp B

7.2 Z eff

1.71

g/cc

TNT

Flake

7.1 Z eff

1.51 g/cc

Emulsio

n

9.2 Z eff

1.37 g/cc

Emulsio

n

8.3 Z eff

1.32 g/cc

CAST

TNT

7.1 Z eff

1.51 g/cc

Tritanol

9.1 Z eff

1.65

g/cc

Emulsio

n

9.8 Z eff

1.44 g/cc

C-4

7.1 Z eff

1.58

g/cc

SEMTE

X

7.2 Z eff

1.47

g/cc

COMP B

7.2 Z eff

1.71

g/cc

Page 47: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 47

Identification of Explosives

Black

Powder

Black

Powder

Replacement

14.2 Z eff

1.2 to 1.2

g/cc

Potassium

Perchlorate

14 Z eff

2.34 g/cc

Smokeless

Powder

7.4 to 7.8 Z

eff

.5 to 1.0 g/cc

Page 48: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 48

Organics, how do you tell the difference

Page 49: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 49

Organics, how do you tell the difference

Page 50: EOD Portable X-ray Enhancements using Dual Energy Imaging

With a dual energy measurement you can DIFFERENTIATE between potential explosives, flammable, and other organic materials

You CANNOT do this with grey scale

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 50

Organics, how do you tell the difference

Page 51: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 51

Organics, how do you tell the difference

Page 52: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 52

Dual Energy provides more information

Page 53: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 VCsecurity 53

Render Safe Grey Scale vs Dual Energy

Page 54: EOD Portable X-ray Enhancements using Dual Energy Imaging

When the

IED looks like

this the render

safe procedure is

easy and grey

scale works great

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 54

Render Safe

Page 55: EOD Portable X-ray Enhancements using Dual Energy Imaging

This is a component basedconstructed IED meaning each part

is all laid out nice and neat. They are not made like this.

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 55

Render Safe

This is a holistic based constructed IED meaning everything is combined

Where is the explosive?

Page 56: EOD Portable X-ray Enhancements using Dual Energy Imaging

You cannot develop an educated RSP with grey scale on a holistic constructed IED

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 56

Render Safe

Page 57: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 57

Reality

Page 58: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 58

Not Reality

Page 59: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 59

Reality

Page 60: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 60

Not Reality

Page 61: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 61

Reality

Page 62: EOD Portable X-ray Enhancements using Dual Energy Imaging

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 62

Not Reality

Page 63: EOD Portable X-ray Enhancements using Dual Energy Imaging

IED’s are complex 3D problems that a 2D grey scale images provide very little ability to solve

Dual energy provides more information that allows you to apply more information to the problem

The goal is a successful RSP and grey scale on real IED’s is a poor tool for the job

09.03.2020 EOD Portable X-ray Enhancements using Dual Energy Imaging 63

Reality

Page 64: EOD Portable X-ray Enhancements using Dual Energy Imaging

Contact

Liron Noar, Security Division Manager: +34 600 796 152

John Howell, Security EOD/IED Specialist: +1 828 564 3456