ENVOL Gas Volume Converter SIS intoduces his new generation of T, PT or PTZ gas volume converter ENVOL. Compliant with MID directive, ENVOL was developed in close cooperation with the admin- istrators of gas networks to offer innovative functionalities in the gas volume conversion, thus minimizing to strict minimum the installa- tion and start-up phase. Its communication capabilities combined with large data logger functionalities make the ENVOL device a high performance gas volume converter.

Upload: hathuan

Post on 30-Jan-2018

286 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ENVOL - scatek.comscatek.com/wp-content/uploads/2017/03/ENVOL-GB.pdf · Certification • ATEX approved : LCIE 08 ATEX 6056 X – CE081 II 1 G Ex ia IIA ou IIB T4 • LNE type examination

E N V O LGas Volume Converter

SIS intoduces his new generation

of T, PT or PTZ gas volume converter ENVOL.

Compliant with MID directive, ENVOL was

developed in close cooperation with the admin-

istrators of gas networks to offer innovative

functionalities in the gas volume conversion,

thus minimizing to strict minimum the installa-

tion and start-up phase.

Its communication capabilities combined

with large data logger functionalities make

the ENVOL device a high performance gas

volume converter.

Page 2: ENVOL - scatek.comscatek.com/wp-content/uploads/2017/03/ENVOL-GB.pdf · Certification • ATEX approved : LCIE 08 ATEX 6056 X – CE081 II 1 G Ex ia IIA ou IIB T4 • LNE type examination

Certification • ATEX approved : LCIE 08 ATEX 6056 X – CE081 II 1 G Ex ia IIA ou IIB T4

• LNE type examination approved• EN12405-1/A1 compliant• MID 2004-22-CE compliant

Pressure • External pressure sensor• 3 meters cable length• 1/4" gas coupling • Conversion pressure ranges :

• 0,8 to 3 bar abs.• 1 to 7 bar abs.• 3 to 24 bar abs.• 18 to 90 bar abs.• Other ranges : on request

Temperature • PT1000 class A probe• 3 meters cable length• -40°C à +70°C range of measurement

Volume input • Low Frequency pulse metering input (20Hz max)• Optional : HF+LF pulse metering input (5 kHz maxi)

Output • 3 digital output on open collector

Communication • USB link for laptop• 2 serial links : Independently programmable,

RS232/RS485, 1200 to 38400 bauds rate

Power Supply • Internal battery (5 years autonomy)*Optional supplies :• External ATEX 230Vac power supply• External ATEX solar power supply

Hardware • IP65 polycarbonat enclosure dimensions H175 x W185x D70mm including wall mounting

• Optional : • Pipe fixing on flange• DIN rail fixing•Various integrations available (cabinets, grids)

Environment • Mechanical : M1.• Electromagnetic : E2• Operating : -25°C à +70°C• Storage : -40°C to +85°C• Humidity : 10 to 93% without condensation

TechnicalENVOL

Funct ional i t iesENVOL

ENVOL is a category 1 T, PT or PTZ gas volume converter in compliance with MID directive. ENVOL is a new generation of gasflow converter that integrates the latest electronic technologies(USB, Flash memory, microprocessor with low power consump-tion,...). Furthermore ENVOL offers advanced Datalogger function-alities and several communication ports (USB and RS232/485)allowing it to be used in any gas billing chain.

ENVOL allows conversion for combustible gasses 1st and 2nd family (according to EN437) and Nitrogen.

ENVOL is approved ATEX to be used in hazardous area (zone 0).

D e s c r i p t i o nENVOL

* Depending on operating conditions

Compressibility Methods : T, PT • AGA8-1, AGA8-2 and AGA8 (DC92)PTZ • AGANX19

• AGANX19BRKHOR 3H• SGERG• Nitrogen table

Volumes • Current hourly, daily, monthly unconvertedand converted volume

• Unconverted and converted indexes• Hourly volumes and indexes registered for

40 days• Daily volumes and indexes registered for

100 days• Monthly volumes and indexes registered

for 14 months• Thresholds on volume overrun

Measurements • Current pressure, temperature and flow values• Daily average pressure and temperature

registered for 80 days

Output • Digital outputs :• Unconverted volume pulse retrans-

mission• Converted volume pulse retransmission• Alarm retransmission (Conversion

stopped, threshold overrun)

Pressure and • Conversion stop thresholds (thresholdtemperarture overrun) parametrables with alarm

management

Conversion alarm • A conversion stop alarm is generatedwhen the converter is overunning thework limits (P, T or calculation method).The following informations are regis-tered :• Conversion stop duration• Hourly converted volume during

alarm• Daily converted volume during alarm• Unconverted index during alarm

• Parametrable standby values are thenused for conversion

Event log • 400 last events recorded (including alarms)

Modbus link • Slave mode• PSTN, GSM/GPRS modem• PLC or RTU linkAdresses table (contact us)

• Master mode• chromatograph with gas parameters

reading for conversion / calculation

Integration example

Page 3: ENVOL - scatek.comscatek.com/wp-content/uploads/2017/03/ENVOL-GB.pdf · Certification • ATEX approved : LCIE 08 ATEX 6056 X – CE081 II 1 G Ex ia IIA ou IIB T4 • LNE type examination

• DisplayENVOL has a graphic display and a two multi-function button keypad. This display allows not only the exploitation of the recordeddatas but also the configuration of the main parameters.

• SoftwareENVOL can be configured and operated via a laptop with the SESAME software, locally or remotely thanks to its intuitive anduser-friendly interface. (Refer to SESAME software brochure).

Display : D Sésame : S

Configuration D SGas parameters(pulse weight, P, CO2, H2, PCS, …) Converted alarms thresholds Unconverted and converted indexes System informations Digital outputs (Vb, Vm, conversion stop transmission…) Communication links (Modem, RTU, Chromatograph, …) Communication protocol (Modbus RTU, Modbus TCP, …) Firmware updates log

Consultation D SInstantaneous indexes values (Vm, Vb, conversion stop, …)

Instantaneous metrological meauserements (P, T, C, Zb,…)

Gas parameters (pulse weight, P, CO2, H2, PCS, …)

Conversion alarm thresholds

Power level (internal battery autonomy, …)

Alarm index (Vma, Vba, C,…)

Hourly/daily/monthly Instantaneous volumes

End of month volumes indexes recorded over 14 months

Hourly volumes over 40 days

Hourly average measurements (P,T) over 40 days

Daily volumes over 100 jours

Daily average measurements (P,T) over 100 days

Monthly volumes over 14 months

Metrological alarms log

Not metrological alarms log (events)

System informations

Maintenance D SCalibration mode Indexes values modification Battery level update Temperature calibration Pressure offset modification (pressure) Exceed pressures on sensors log

Conf igurat ion, operat ing and maintenanceENVOL

Man / Machine Inter faceENVOL

For a full solution, SIS offers a wide range of services to satisfy the requirements of the market : installation, put into service incompliance with the statutory legal metrology obligations, service contract for a total number of equipments.

Ser v icesENVOL

Page 4: ENVOL - scatek.comscatek.com/wp-content/uploads/2017/03/ENVOL-GB.pdf · Certification • ATEX approved : LCIE 08 ATEX 6056 X – CE081 II 1 G Ex ia IIA ou IIB T4 • LNE type examination

CHROMATOGRAPH

Laptop + SESAME

RTU GSM - GPRS RTU - GSM - GPRS PLC

S C A D A

SENTINELLEUNI 1000 OTHER

SYSTEMS

01 1001 100

USB

01 1001 100

01 1001 100 - (MODBUS)RS232/485

Z.I . LES PALUDS AVENUE DE LA FLEURIDE13685 AUBAGNE CEDE XFRANCE

Tel . +33 (0) 4 42 82 90 05 Fax +33 (0) 4 42 70 26 87 Emai l : commerc ia [email protected] : www.sevme.com

P TLFHF

RTU

MODBUSRS232/485

ATEX power supply(option)

Prin

ted

in F

ranc

e 09

/10

– Sp

ecifi

cati

ons

subj

ect

to c

hang

e w

itho

ut n

otic

e –

All R

ight

s Re

serv

ed –

ww

w.in

apol

egra

phiq

ue.c

om