enhance your aged infrastructure without impacting operations
TRANSCRIPT
Enhance your aged infrastructure without impacting operations
December 16, 2015
Use this slide to write
impactful and call-to-
action types of
messaging
To insert a new slide with this template, go to the Home tab (up top),
Slide.
View the webcast replay
http://bit.ly/1JgHrvM
Our speakers for today’s webcast
Rabin Mahanty Sales director, H5 Data Centers Rabin is passionate about leading and driving sales
through quality long term business partnerships. Not
only are relationships with customers important, but
also vendors. Referrals and recommendations are
the lifeblood of the business.
Philip Fischer Global data center segment manager, Eaton Phil is guided by the principle that anything is possible;
and is passionate about ensuring increased efficiency
that does NOT sacrifice uptime in the data center.
Lifecycle of a data center
How do you…
• Optimize the data center
as a long term asset?
• Maintain a cutting edge
facility and ensure
trouble- free operation?
• Ensure compliance
with your proposed
timeline within
budgeted costs? Reliability Safety Efficiency
Who is H5 Data Centers?
• Privately-held wholesale data center
company, founded in 2011
• More than 1 million SF under
management
• 7 US markets, coast-to-coast
• Ashburn, Atlanta, Charlotte, Denver,
San Jose, San Luis Obispo,
Phoenix, Seattle
• Nimble and entrepreneurial team
headquartered in Los Angeles
• Target long-term ownership and
management of mission-critical assets
7 Data center markets, over 1 million square
feet
Wholesale Data Center Focus
Retail
Colocation
Wholesale
Data Center
(Turn-Key)
Powered
Shell Data
Centers
Cloud &
Managed
Services
Customers typically control mechanical & electrical equipment
Lower rental rates
Ability for customer to depreciate assets
Long-term leases
H5 manages mechanical & electrical equipment and environmentals
H5 responsible for maintenance and asset reliability
Higher rental rates
Medium to long-term term leases
Customers license smaller space – often small cages or cabinets
Data center providers manage mechanical & electrical equipment and environmentals
Short or long-term leases or licenses
Customers pay for compute, storage, communication and security services
Service provider owns and operates hardware and its customers may not physically see the data center site
Service provider may offer traditional retail colocation with a hybrid of managed services
H5 F
ocus
H5 Data Center background
H5 business challenges and requirements
• Maintain reputation of 100% uptime during renovation
• Simplified holistic project approach
• Single source supplier that can help maximize use of data center
• Balance between investment for infrastructure vs. customer revenue
• How to maximize the lifetime of existing equipment while integrating new technologies
H5 Denver data center
Location:
5350 S. Valentia Way in the Denver Tech Center
Description:
12-acre campus supporting nearly 300,000 SF of data center
and office space
Power:
17.5 MW of gross generator capacity
Network:
Access to nearly every major Denver metro fiber provider
Space for Lease:
More than 50,000 SF of raised floor available – with private
suites or customer cages
Other:
Purpose-built data center originally constructed by United
Airlines
Project Start – End:
June 2015 – Mar 2016
15-year average employee
tenure and 10+ years of zero
downtime
Major tenants include Fortune
500 companies such as
Wyndham Hotels and Realogy
Recently announced $10+
million in planned improvements
H5 data center project overview
West Building:
• Complete turnkey solution by Eaton
including engineering, procurement and
construction
• Replace existing 3MVA UPS system with
scalable Eaton 9395 parallel UPS solution
• Initial capacity 1.5MVA scalable to
3MVA
• Reduce initial build-out costs and give H5
flexibility to add capacity in the future
• Customized switchgear solution for UPS
paralleling/bypass board to work with
existing limited overhead clearance
Custom switchgear solution
H5 data center project overview
East Building:
• Complete turnkey solution by Eaton
• Design by Swanson Rink
• Replaced entire critical power system
including main switchgear, ATS’s,
UPS and critical power distribution
• Created custom busway solution to
transition from existing busway to
new Eaton busway
Use this slide to write
impactful and call-to-
action types of
messaging
Why a single source supplier?
• Overcome misconceptions of
manufacturers
• Benefits of project management
• Risk management
• Quick response for project
fluctuations
© 2015 Eaton. All Rights Reserved.
•
•
•
Being vintage is not always a good thing
• Aging equipment
• Low efficiency and power cooling
• Inability to scale or adapt to new technologies
• Regulatory compliance
And that’s not all…what about disaster recovery,
security, speed to deploy, etc…
© 2015 Eaton. All Rights Reserved.
• Optimal reliability and availability
• Lower TCO through improved efficiency
• Improved safety
• Enhanced flexibility and functionality
• Improved serviceability
• Greater scalability
• Enhanced user perception
Benefits of upgrades
© 2015 Eaton. All Rights Reserved.
Replace old UPS hardware
• Low risk and relatively low cost
• Better efficiency can often fund upgrades
• Improved reliability
• Increased monitoring capability
100%
95%
90%
85%
80% 0% 10% 20% 30%
Syst
em
Eff
icie
ncy
40%
9395 ESS Percent Load
9395 Double conversion 9395 VMMS
© 2015 Eaton. All Rights Reserved.
Energy efficient UPSs can help grow revenue
Implement containment and economizer technologies
• Hot or cold aisle containment is possible
depending on application
• Increases overall efficiency of data center
• Higher inlet temperatures
• More time spent in economizer modes
• Extends capacity of existing cooling plant
• Allows for higher density deployments
Update power distribution systems
• Eliminate or upgrade
transformers
• Update components in
distribution systems
• Improve rack power distribution
• Conduct power system, harmonic
and coordination studies
• Match redundancy of electrical
architecture to application need
Consider robust monitoring & operations
• Convergence of monitoring and management to drive energy efficiency, asset
management and enhanced IT workflows
• Energy can’t be managed if it’s not measured
• Various metering solutions can do simple energy management through transient
detection
• Imbed in distribution equipment or stand alone
Enhance electrical safety and regulatory compliance
Technology
• OSHA – Arc Flash and Safety
• IEC – Harmonics to grid
• EU Code of Conduct – UPS Efficiency
Environmental
• Carbon Tax
• Energy Star – UPS and data centers
• LEED
• OSHPD
In many countries, violation is penalized and
compliance rewards are financial
Food for thought…
• Best practices can be applied across all data
centers
• An older infrastructure can be improved - new
white papers explain how:
1. Top reasons to upgrade vintage data
centers
2. Best practices for modernizing vintage data
centers
• Utilities offer rebates and awards
Use this slide to write
impactful and call-to-
action types of
messaging
Performance translates to money with
utility rebates
• Why do utilities offer rebates?
• Regulatory requirements
• New generation avoidance
• Peak demand generation costs
• Green image
• Find out your state incentives
• Eaton energy efficiency programs
Explore Eaton capabilities at the Power Tour
View success in action
• Best practice customer data centers
• Manufacturer experience centers and factory
tours
Considerations for the future
Good “Bones”
Atmospheric Conditions
Energy Sustainability
Network Access & Latency
Geopolitical Risk Factors
Long-term operability and sustainability
Energy cost
Use this slide to write
impactful and call-to-
action types of
messaging
To insert a new slide with this template, go to the Home tab (up top),
Slide.
For more information:
• H5 Data Centers Selects Eaton to Help Increase Efficiency and Maintain
High Availability in Denver Colocation Facility
• Read more about H5 Data Centers
• Learn more about Eaton capabilities with data center solutions
www.eaton.com/datacenters
Use this slide to write
impactful and call-to-
action types of
messaging
To insert a new slide with this template, go to the Home tab (up top),
Impactful Slide.
Questions and answers
Philip Fischer
Global Data Center Segment Manager
508.259.5100
https://twitter.com/fischerphilip
Rabin Mahanty
Sales Director, H5 Data Centers
303.714.7803
linkedin.com/in/rabinmahanty
Use this slide to write
impactful and call-to-
action types of
messaging
To insert a new slide with this template, go to the Home tab (up top),
Impactful Slide.
Thank you!