engineers architects roof replacement...deck. replace damaged or deteriorated roof deck on a unit...
TRANSCRIPT
Titlesheet
A-0.0
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
1. Contractor to verify all conditions and dimensions in the field. Notify Architect/Engineer(A/E) of any variation from Drawings. Do not scale Drawings.
2. Contractor shall secure and pay for Permits, Government Fees and Licenses asrequired by the Village of Hoffman Estates for proper execution and completion of thework.
3. All exits are to remain open and operable as a means of egress from the building at alltimes. Provide adequate protection for all building occupants and pedestriansthroughout the duration of the repair work.
4. Contractor to provide close-up/hands-on scaffolding access for A/E to observe allrepairs during the course of the repairs.
5. Contractor shall coordinate any storage of materials at the building with the Owner.
6. Contractor shall repair any damage to the building (walls, roof, etc.), landscaping, andadjacent properties caused by the Contractor to the satisfaction of the Owner.
7. A certificate of insurance meeting the requirements as outlined by the Owner must beprovided and approved prior to materials being stored on site and commencement ofwork.
8. Parapet Hooks will not be acceptable for swing stage rigging.
9. Do not overload roof with construction materials and/or equipment. Coordinate locationfor storage in parking lot with building.
A-0.0 TitlesheetA-1.0 Roof PlanA-2.0 Metal Roof DetailsA-2.1 Metal Roof DetailsA-2.2 Metal Roof DetailsA-3.0 Alternate 1: PVC Roof DetailsA-3.1 Alternate 1: PVC Roof Details
INDEX OF DRAWINGS
LOCATION MAP:
GENERAL NOTES
Triphahn CenterRoof Replacement1685 West Higgins RoadHoffman Estates, Illinoisfor: Hoffman Estates Park District
1685 West Higgins RoadHoffman Estates, Illinois
by: 330 Pfingsten RoadWiss, Janney, Elstner Associates, Inc.WJE ENGINEERS
ARCHITECTSMATERIAL SCIENTISTS Northbrook, IL 60062
847.272.7400 tel | 847.480.9534 fax
A-4.0 Alternate 2: PVC Roof DetailsA-5.0 Translucent Panel DetailsA-5.1 Translucent Panel Details
SUMMARY OF WORK
Base Bid:In general, the scope of work includes the following:
1. Remove metal roofing panels and underlayment to existing insulation layer.
2. Over existing insulation, install plywood/polyisocyanurate composite board.
3. Remove metal wall panels to existing substrate.
4. Install felt underlayment and waterproof underlayment over plywood surface and install battenseam metal roof system.
5. Install flush seam metal wall panel system with continuous insulation behind.
6. Remove and replace translucent skylight and wall panel system.
Alternate No. 1: (Provide single-ply membrane in lieu of metal panels)1. Remove all existing roofing, flashings and underlayment down to the existing insulation.
2. Replace damaged or deteriorated insulation on a unit price basis.
3. Mechanically fasten 3" polyisocyanurate insulation and 12" DensDeck Prime gypsum roof boardthrough the existing insulation into the steel deck at the rate of one fastener per 2 square feet.
4. Fully adhere a 60 mil fleece-back PVC membrane to the gypsum board substrate.
5. Heat weld simulated standing seam extrusions to the membrane.
TRIPHAHN CENTER
Alternate No. 2:1. Remove all existing roofing, flashings, and insulation down to the existing metal deck.
2. Replace damaged or deteriorated roof deck on a unit price basis.
3. Mechanically fasten 5 12" polyisocyanurate insulation and 12" gypsum board into the steel deckat the rate of one fastener per 2 square feet.
4. Install a 60 mil fully adhered PVC roofing membrane and associated flashings.
Roof Plan
A-1.0
As Shown
Roof PlanScale: 1/16" = 1'-0"1
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
N
METAL ROOF
METAL ROOF
TRANSLUCENT SKYLIGHT PANELS
TRANSLUCENT SKYLIGHT PANELS
SINGLE-PLY MEMBRANEROOF
CONDENSERUNIT
RELIEFVENT
CONDENSERUNIT
EXHAUST FAN
EXHAUSTFAN
EXHAUST FAN
132'-1"
132'
-0"
71'-10" 64'-6"
29'-0
"8'
-2"
136'-4"
8'-1"
CHIMNEY STACK
1
ROOF REPLACEMENT NOTE LEGENDMARK
2
A-5.1
6
24'-0
"
1 4
2
2
2
2
5
1
4
F
BASE BID (METAL ROOFING) - REMOVE ALL EXISTING ROOFING, FLASHINGS, ANDUNDERLAYMENT DOWN TO THE EXISTING INSULATION. REPLACE DAMAGED ORDETERIORATED INSULATION ON A UNIT PRICE BASIS. MECHANICALLY FASTEN APLYWOOD/ POLYISOCYANURATE COMPOSITE BOARD CONSISTING OF 3 INCHPOLYISOCYANURATE INSULATION AND 3/4 INCH CDX PLYWOOD THROUGH THEEXISTING INSULATION INTO THE STEEL DECK AT THE RATE OF ONE FASTENERPER SQUARE FOOT. INSTALL A #30 FELT UNDERLAMENT OVER THE SUBSTRATESURFACE AND A SELF-ADHERED WATERPROOFING UNDERLAYMENT AT EAVES,SADDLES, WALLS, AND EQUIPMENT PENETRATIONS. MECHANICALLY FASTEN A26 GAUGE BATTEN SEAM METAL ROOF SYSTEM AND FLASHINGS. SEE DETAIL1/A-2.0 FOR NEW ROOF ASSEMBLY.
BASE BID (TRANSLUCENT SKYLIGHT PANELS) - REMOVE AND REPLACE EXISTING
234" DEEP TRANSLUCENT SKYLIGHT SYSTEM AND ASSOCIATED BLOCKING AND
FLASHINGS. INSTALL NEW INTERIOR TRIM TO CONCEAL BLOCKING.
3BASE BID (TRANSLUCENT WALL PANELS) - REMOVE AND REPLACE EXISTINGTRANSLUCENT WALL PANEL SYSTEM. THIS IS TO INCLUDE THE REPLACEMENTOF SOFFIT PANELS AT BASE OF WALL PANELS.
4ALTERNATE 1 (SINGLE-PLY ROOFING) - REMOVE ALL EXISTINGROOFING, FLASHINGS, AND UNDERLAYMENT DOWN TO THE EXISTINGINSULATION. REPLACE DAMAGED OR DETERIORATED INSULATION ON A UNITPRICE BASIS. MECHANICALLY FASTEN 3” POLYISOCYANURATE BOARDAND 1/2” DENSDECK PRIME GYPSUM ROOF BOARD THROUGH THE EXISTINGINSULATION INTO THE STEEL DECK AT THE RATE OF ONE FASTENER PER 2SQUARE FEET. FULLY ADHERE A 60 MIL FLEECE BACK PVC MEMBRANE TO THEGYPSUM BOARD SUBSTRATE AND HEAT WELD SIMULATED STANDING SEAMEXTRUSIONS TO THE MEMBRANE. SEE DETAIL 1/A-3.0 FOR NEW ROOFASSEMBLY.
5ALTERNATE 2 (LOW-SLOPE ROOFING) - REMOVE ALL EXISTINGROOFING, FLASHINGS, AND INSULATION DOWN TO THE EXISTING METALDECK. REPLACE DAMAGED OR DETERIORATED ROOF DECK ON A UNIT PRICEBASIS. MECHANICALLY FASTEN 5 1/2” POLYISOCYANURATE INSULATIONAND 1/2” GYPSUM BOARD INTO THE STEEL DECK AT THE RATE OF ONEFASTENER PER 2 SQUARE FEET. INSTALL A 60 MIL FULLY ADHERED PVCROOFING MEMBRANE AND ASSOCIATED FLASHINGS. SEE DETAIL 1/A-4.0 FORNEW ROOF ASSEMBLY.
6VERTICAL WALL PANELS (BASE BID AND ALTERNATE 1) - REMOVE EXISTINGWALL PANELS AND UNDERLAYMENT TO SUBSTRATE. INSTALL NEW MOISTUREBARRIER OVER EXISTING SUBSTRATE AND INSTALL NEW 2 INCHPOLYISOCYANURATE INSULATION OVER WALL SUBSTRATE. INSTALL NEWHORIZONTAL HAT CHANNEL FURRING 24 INCHES O.C. OVER NEW THERMALCLIPS ATTACHED TO THE EXISTING SUBSTRATE. MECHANICALLY ATTACH NEW12 INCH FLUSH SEAM PANELS TO THE HORIZONTAL FURRING. SEE DETAIL2/A-2.0.
7TIE-IN AT SOUTH BUILDING - REMOVE EXISTING MEMBRANE AT DRAINAGESADDLE. CUT SADDLE FLUSH WITH WALL OF ADJACENT BUILDING AT NORTHEND OF SADDLE. INSTALL WATERPROOFING UNDERLAYMENT ON SADDLE ANDMINIMUM 3 FEET UP THE FIELD OF THE ROOF. REMOVE EXISTING COPING ANDEXTEND WATERPROOF UNDERLAYMENT UP ADJACENT WALL TO TOP OF THEPARAPET. INSTALL SHEET METAL ROOFING PANELS AT SADDLE AND INTEGRATEWITH FIELD PANELS. INSTALL EPDM MEMBRANE OVER TOP OF PARAPET WALLAND SEAL TO PENETRATIONS. INSTALL NEW COPING METAL AND SEAL ATPENETRATIONS THROUGH COPING WITH PMMA LIQUID FLASHING MEMBRANE.
8TYPICAL GUTTER EDGE - INSTALL WOOD BLOCKING AT PERIMETER TO MATCHHEIGHT OF INSULATION AND NAILBASE ASSEMBLY. MECHANICALLY FASTENGUTTER TO WOOD BLOCKING AND STRIP-IN FLANGE WITH WATERPROOFUNDERLAYMENT. SET Z-RETAINER STRIP IN SEALANT AND ENGAGE METALPANEL EDGE INTO Z-RETAINER. SEE DETAIL 3/A-2.0.
9CHIMNEY STACK - REMOVE EXISTING FLASHING COLLAR AND SAVE FOR REUSE.REMOVE FLASHING SLEEVE TO EXPOSE CHIMNEY STACK. FABRICATE NEWSHEET METAL FLASHING SLEEVE AND INTEGRATE INTO METAL ROOF SYSTEM.REINSTALL FLASHING COLLAR AND SEAL ALONG TOP EDGE. SEE DETAIL3/A-2.2.
10VENT STACKS - FABRICATE METAL SLEEVE APPROXIMATELY 1 INCH LARGERTHAN THE DIAMETER OF THE PIPE AND MECHANICALLY ATTACH TO THEBOTTOM SIDE OF THE METAL PANEL IN A SOLID BED OF BUTYL SEALANT.APPROXIMATELY 1 INCH ABOVE THE TOP OF THE COLLAR, INSTALL A SHEETMETAL STORM COLLAR SECURED TO THE VENT STACK PIPE WITH A STAINLESSSTEEL DRAWBAND. INSTALL SEALANT ALONG THE TOP EDGE OF THE COLLARAND AT THE JUNCTION OF THE METAL ROOF PANEL AND FLASHING SLEEVE.
11PLUMBING VENTS (BASE BID) - FABRICATE METAL SLEEVE APPROXIMATELY 1INCH LARGER THAN THE DIAMETER OF THE PLUMBING VENT PIPE ANDMECHANICALLY ATTACH TO THE BOTTOM SIDE OF THE METAL PANEL IN ASOLID BED OF BUTYL SEALANT. INSTALL A SHEET METAL FLASHING CAP OVERTHE TOP OF THE PIPE OVERLAPPING THE FLASHING SLEEVE 2 INCHES. FASTENFLASHING CAP TO THE FLASHING SLEEVE WITH RIVETS.
12SNOW RETENTION - SET EPDM GASKET ON ROOF PANEL AND INSTALL SNOWRETENTION BRACKETS 16" O.C. IN BUTYL MASTIC. MECHANICALLY FASTENBRACKET INTO STEEL DECK WITH STAINLESS STEEL FASTENERS WITH EPDMWASHERS. INSTALL SEALANT OVER FASTENERS AND INSTALL A COVE BEAD ATPERIMETER OF BRACKET. INSTALL TUBING PER MANUFACTURERRECOMMENDATIONS. SEE DETAIL 4/A-2.1.
13MECHANICAL CURBS - REMOVE EXISTING FLASHINGS AT THE PERIMETER.LOCATIONS OF EACH EQUIPMENT SUPPORT. ADD WOOD BLOCKING ALONGTHE EXISTING CURB RAIL TO PROVIDE SUITABLE FLASHING HEIGHTS.DISCONNECTION AND RECONNECTION OF MECHANICAL EQUIPMENT, IFREQUIRED, SHALL BE INCLUDED IN THE BASE BID. INSTALL NEW SHEETMETAL “SKIRT” FLASHINGS SET BENEATH THE DOWNWARD LEG OF THE SHEETMETAL FLANGE. DETAIL SIMILAR TO 3/A-4.0.
14ROOF DRAINS - EXISTING PRIMARY ROOF DRAINS TO REMAIN. SEE TYPICALDRAIN DETAIL 2/A-4.0 FOR REQUIRED PROCEDURE FOR EACH DRAIN LOCATION.NOTE THAT CAST IRON GRATINGS MAY BE REUSED AND PLASTIC GRATINGSWILL NOT BE ACCEPTED.
15ROOF HATCH - REMOVE EXISTING FLASHINGS AT THE PERIMETER OF ROOFHATCH. TEMPORARILY REMOVE HATCH AND ADD WOOD BLOCKING TOPROVIDE SUITABLE FLASHING HEIGHTS. INSTALL NEW SHEET METAL "SKIRT"FLASHINGS SET BENEATH THE DOWNWARD LEG OF THE SHEET METAL HATCHCOVER. SEE DETAIL 4/A-4.0.
16PLUMBING VENTS (ALTERNATES) - REMOVE EXISTING FLASHINGS AT PIPES.INSTALL FIELD MEMBRANE TO PIPES, MECHANICALLY FASTEN, AND INSTALL AFLASHING BOOT OVER PIPE. INSTALL SEALANT BEHIND TOP EDGE OF BOOT,INSTALL STAINLESS STEEL CLAMP, AND INSTALL SEALANT OVER TOP EDGE OFTHE BOOT.
F
6TYP.
10
8TYP.
6TYP.
13TYP.
11TYP.
15
8TYP.
12
7
9
3
3
A-5.1
5
A-5.0
2
A-5.0
3
A-2.1
3
A-2.1
2
A-2.1
1
4'-0"
Metal Roof Details
A-2.0
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
Metal Roof System DetailScale: 3" = 1'-0"1
BATTEN SEAM METAL ROOFPANEL
RED ROSIN SLIP SHEET
#30 FELT UNDERLAYMENT
NEW 3"POLYISOCYANURATE/3
4" PLYWOOD COMPOSITENAIL BASE
EXISTING 3" INSULATION TOREMAIN
Gable DetailScale: 3" = 1'-0"5
EXISTING METAL ROOFDECK
Gutter DetailScale: 3" = 1'-0"3
BATTEN SEAM METAL ROOFPANEL
RED ROSIN SLIP SHEET
#30 FELT UNDERLAYMENT
BATTEN CLIP WITH FASTENERS
NEW 3" POLYISOCYANURATE /3
4" PLYWOOD COMPOSITE NAILBASE
EXISTING 3" INSULATION TOREMAIN
EXISTING METAL ROOF DECK
GABLE FLASHING WITH"J" CLOSURE
FIELD-FORM PANEL LEGTO I.D. OF "J" CLOSURE
ADD WOOD NAILERS ASNECESSARY TO MATCHHEIGHT OF NAIL BASE
BLOCK WALL
CONTINUOUS CLEAT
SEALANT
SLOPE 412":12"
RED ROSIN SLIP SHEET
WATERPROOF UNDERLAYMENT
GUTTER FLASHING
GUTTER STRAP(FIELD-FORMED)
SNAP-ON BATTEN CAP
SNAP-ON BATTEN CLIP
NEOPRENE END PLUG
PANEL
"Z" RETAINER STRIP SETIN SEALANT
NEW 3" POLYISOCYANURATE /3
4" PLYWOOD COMPOSITE NAILBASE
EXISTING 3" INSULATION TOREMAIN
EXISTING METAL ROOF DECK
2 New Coping DetailScale: 3" = 1'-0"
BASE BID-EXISTING ROOF MEMBRANE ANDSHEATHING TO REMAIN.EXISTING BATT INSULATION INSTUD SPACES TO REMAIN.ALTERNATE 2-INSTALL NEW NAILBASEINSULATION ON THE ROOF SIDEOF PARAPET. ADHERE NEWROOF MEMBRANE TO NAILBASE.FILL STUD SPACES WITHSPRAYFOAM INSULATION.
NEW CONTINUOUS WOODBLOCKING. FASTEN TO STUDTRACK AT 16" O.C. WITH 14"SCREWS.
NEW 0.625" PREFINISHEDALUMINUM COPING. FASTEN TOBLOCKING AT ROOF SIDE.
LAP ROOF MEMBRANEOVER AIR/MOISTUREBARRIER AND SET INFULL BED OF SEALANT.NAIL IN PLACE.
3"
NEW CONTINUOUSCLEAT
NEW FLUSH SEAMMETAL PANEL SYSTEM
NEW 2" RIGIDINSULATION
NEW THERMAL CLIPS
NEW AIR/MOISTUREBARRIER. EXTEND ONTOTOP OF BLOCKING FORCOPING.
NEW HORIZONTALFURRING
MECHANICALLY FASTENAIR/MOISTURE BARRIERAT OVERHANG
Fascia to Soffit Flashing DetailScale: 3" = 1'-0"4
NEW METAL PANEL SYSTEM
MANUFACTURER'SFASCIA TO SOFFITFLASHING
NEW 2" RIGID INSULATION
NEW HORIZONTALFURRING
NEW THERMAL CLIPS
NEW AIR/MOISTUREBARRIER. ADHERE TOSOFFIT PANEL.
EXISTING SOFFIT PANELTO REMAIN
FASTENER
EXISTING WALL FRAME ANDINSULATION
NEW METAL PANELSYSTEM
RIVET
SNAP-ON BATTEN COVER
ADD WOOD BLOCKING ASNECESSARY TO MATCH HEIGHTOF ASSEMBLY
A-5.0
3
A-5.0
2
A-2.0
2
Metal Roof Details
A-2.1
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
Coping Detail atBuilding Tie-InScale: 3" = 1'-0"3
EPDM MEMBRANE OVER TOP OFPARAPET
COPING METAL FASTENED 24"O.C. THROUGHCOUNTERFLASHING
SHEET METALCOUNTERFLASHING INSTALLEDBEHIND COPING
EXISTING PVC MEMBRANE
CONTINUOUS CLEATFASTENED 12" O.C.
SHEET METAL SADDLEFLASHING
WATERPROOFUNDERLAYMENT
GENERAL NOTES:1. ALL PENETRATIONS THROUGH COPINGMETAL SHALL BE FLASHED ONTO THESURFACE OF THE COPING METAL WITHPMMA MATERIAL
Metal Roof to Saddle TransitionScale: 1 1/2" = 1'-0"2
RED ROSIN SLIP SHEET
UNDERLAYMENT
SHEET METAL SADDLE
1"2'-
0"
METAL ROOF PANEL
SLO
PE
SNAP-ON BATTENCOVER
INSTALL SEALANT ATENDS OF VERTICALSEAMS
LOCK PANEL PANS TOENGAGE EDGE METAL ROOF SUBSTRATE
Metal Roof to New Addition TransitionScale: 1 1/2" = 1'-0"1
6" MIN. OVERLAP METALVALLEY PIECE 6" MIN.OVER ROOF PANEL
SHEET METAL VALLEYFLASHING, RUN DOWNFACE OF CRICKET
MATCH THE CONTOUROF THE METAL ROOFPANEL
2 BEADS OFSEALANT INOVERLAP
NEOPRENE END PLUG
Snow Guard Bracket DetailScale: 3" = 1'-0"4
WATER CUTOFF MASTICBETWEEN EPDM ANDBRACKET. TYP. EACHFASTENER.
SILICONE SEALANTOVER FASTENER, TYP.
SNAP-ON BATTEN SEAM
SELF-ADHERING EPDMUNDER BASE PLATE
ALPINE SNOW PP145 HI PIPEBRACKET AT 16" O.C. SECUREDTO METAL ROOF DECK WITHFOUR FASTENERS PER BRACKET
TUBING INSTALLED PERMANUFACTURERRECOMMENDATIONS
COVE BEAD OF SEALANT, MIN.1
4" BOND TO BOTH THE BASEPLATE AND ROOF PANEL
RED ROSIN SLIP SHEET
#30 FELTUNDERLAYMENT
NEW 3"POLYISOCYANURATE/3/4" PLYWOODCOMPOSITE NAIL BASE
EXISTING 3" INSULATIONTO REMAIN
EXISTING METAL ROOFDECK
2"
TYPICAL METALROOF PANEL
SNAP-ON BATTENCOVER (TYP.)
SURFACE MOUNTEDCOUNTERFLASHINGFASTENED 12" O.C.
SEALANT
Metal Roof Details
A-2.2
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
RED ROSIN SLIP SHEET
Vent Stack FlashingScale: N.T.S.2
Boiler Flue FlashingScale: N.T.S.3
Hip Cap FlashingScale: N.T.S.4
Plumbing Vent FlashingScale: N.T.S.1
UNDERLAYMENT
ROOF SUBSTRATE
FLASHING CAP
METAL FLASHING SLEEVE
SLEEVE FLANGE BELOW
FASTEN FLASHING SLEEVEFLANGE TO ROOF PANELAND NOT TO DECK SO ASNOT TO FIX PANEL ATPENETRATION
SEALED SEAM
SNAP-ON BATTEN SEAM COVER
MIN. 2 BEADS OF SEALANTPLACED BETWEEN UPSLOPEFLASHING FLANGE AND TOPSIDE OF PANEL
SEAL ENDS OF SEAMS
RED ROSIN SLIP SHEET
UNDERLAYMENT
ROOF SUBSTRATE
6" MIN. OVERLAP AND SEALANT
NEW METAL FLASHING SLEEVEINTEGRATED INTO METALROOFING PANELS WITHMATCHING PROFILE
METAL ROOF PANEL
REMOVE FLASHINGSKIRT AND REINSTALL
NEW SEALANT AT EDGEOF FLASHING SKIRT
SHEET METAL FLASHING
SLOPE
SLOPE
SLOPE
SHEET METAL HIP CAP
Z-CLOSURE FASTENED ANDSET IN SEALANT. DO NOTSEAL VERTICAL LEGS.
METAL ROOF PANEL
SNAP-ON BATTEN SEAMCOVER
RED ROSIN SLIP SHEET
UNDERLAYMENT
NAIL BASE SUBSTRATE
EXISTING INSULATION
METAL ROOF DECKING
TEMPERATURE-APPROPRIATESEALANT
STAINLESS STEEL DRAWBAND
SHEET-METAL RAIN COLLAR
GASKETED FASTENERS- SECUREFLASHING SLEEVE FLANGE TOROOF PANEL AND NOT TO DECKSO AS NOT TO FIX PANEL ATPENETRATION
SET SHEET METAL SLEEVE INCONTINUOUS BEAD OF SEALANT
SNAP-ON BATTENSEAM COVER
RED ROSIN SLIP SHEET
UNDERLAYMENT
ROOF SUBSTRATE
INSULATION APPROPRIATEFOR STACK TEMPERATURE
SHEET METAL FLASHINGSLEEVE
METAL ROOF PANEL
4" MIN. FLANGE
SEALANT
SLOPE
SLOPE
METAL ROOF PANEL
SNAP-ON BATTEN SEAM COVER
FABRICATE FLASHING TOMATCH CONTOUR OFBATTENS
6" MIN. OVERLAPAND SEALANT
Alternate 1:
PVC Roof Details
A-3.0
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
Simulated Standing Seam Profile (Alternate 1)Scale: 1'-0" = 1'-0"3
Simulated Standing SeamSpacing Layout (Alternate 1)Scale: 1 1/2" = 1'-0"5
Flashing at PVC CoatedMetal Joints (Alternate 1)Scale: 3" = 1'-0"4
PVC COATED METAL
4" WIDE FLASHING STRIP,HOT-AIR WELDED INPLACE
2" WIDE ALUMINUMTAPE OVER JOINT
Snow Guard Detail (Alternate 1)Scale: N.T.S.2
60 MIL PVC MEMBRANE
SIMULATED STANDINGSEAM EXTRUSION
SHEET METALINSERTS
MANUFACTURER'SPROPRIETARY SNOWGUARD RAIL
WOOD BLOCKING
METAL BASE PLATEAND INTEGRAL PVCSTRIPPING
SNOW GUARDBRACKET
SIMULATED STANDING SEAMEXTRUSION
HOT-AIR WELD
PVC Roof System Detail (Alternate 1)Scale: 3" = 1'-0"1
SIMULATED STANDING SEAMEXTRUSION
60 MIL FLEECE-BACKED PVCMEMBRANE ADHERED
INSULATION FASTENER ANDPLATE1
2" COVER BOARD
NEW 2 12" POLYISOCYANURATEINSULATION
EXISTING 3" INSULATION TOREMAIN
EXISTING METAL ROOF DECK
4"
2"
1/4"
4" MIN.
1'-6 3/4" 1'-6 3/4" 1'-6 3/4" 1'-6 3/4"
60 MIL PVC MEMBRANE,ADHERED
COVER BOARD
NEW 2 12" POLYISOCYANURATEINSULATION
Alternate 1:
PVC Roof Details
A-3.1
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
Gravel Stop Metal Edge (Alternate 1)Scale: 3" = 1'-0"1
EXISTING 3" INSULATION TOREMAIN
NEW 212" POLYISOCYANURATE
INSULATION
COVER BOARD
60 MIL PVC MEMBRANE
PVC COATED METALFASTENED 4" O.C.,STAGGERED USING 1"GALVANIZED ANNULARRING NAILS OR OTHERACCEPTABLE FASTENER
CONTINUOUS CLEAT(MIN. 22 GA.)
WOOD NAILERS TOMATCH HEIGHT OFINSULATION AND COVERBOARD
PVC COATED METALWATER DAM
PVC FLASHING STRIP, HOT-AIRWELDED
EXISTING METAL ROOF DECK
Gutter Detail (Alternate 1)Scale: 3" = 1'-0"2
METAL GUTTER
METAL GUTTERSUPPORT 24" O.C.
PVC CLAD METALFASTENED 4" O.C.,STAGGERED USING 1"GALVANIZED ANNULARRING NAILS OR OTHERACCEPTABLE FASTENER
PVC FLASHING STRIP,HOT-AIR WELDED
WOOD NAILERS TOMATCH HEIGHT OFCOVER BOARD
60 MIL PVC MEMBRANE
COVER BOARD
NEW 212" POLYISOCYANURATE
INSULATION
EXISTING 3" INSULATION TOREMAIN
EXISTING METAL ROOF DECK
Vent Stack Flashing (Alternate 1)Scale: 3" = 1'-0"3 Plumbing Vent Detail (Alternate 1)
Scale: 3" = 1'-0"4
60 MIL PVC MEMBRANE,MECHANICALLY ATTACHED
COVER BOARD
NEW 212" POLYISOCYANURATE
INSULATION
EXISTING METAL ROOF DECK
PRE-MOLDED PVC PIPE BOOT
STAINLESS STEEL HOSE CLAMP
SEALANT AT TOP EDGE
PLUMBING VENT PENETRATION
8" M
IN.
1" M
IN.
EXISTING 3" INSULATION TOREMAIN
60 MIL PVC MEMBRANE,MECHANICALLY ATTACHED
COVER BOARD
NEW 212" POLYISOCYANURATE
INSULATION
EXISTING METAL ROOF DECK
EXISTING 3" INSULATION TOREMAIN
PVC BASE FLASHING
PVC FLASHING MEMBRANE
FIBERGLASS BATT
SHEET METAL SLEEVE
VENT STACK
RAIN COLLAR WITH HIGHTEMPERATURE SEALANTSTAINLESS STEEL HOSE CLAMP
NOTE: REFER TO SHEET A-2.0 FORNOTES RELATED TO WALL PANELS
Alternate 2:
PVC Roof Details
A-4.0
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
Roof System Detail (Alternate 2)Scale: 3" = 1'-0"1
FULLY ADHERED 60 MIL PVCMEMBRANE
TWO LAYERS OF 212"
POLYISOCYANURATEINSULATION, ADHERED
58" SUBSTRATE BOARD
MECHANICALLY ATTACHED TOMETAL DECK AT THE RATE OFONE FASTENER PER 2 SF.
EXISTING METAL ROOF DECK
AIR / VAPOR BARRIER
Roof Drain Detail (Alternate 2)Scale: 3" = 1'-0"2
Removable Curb Flashing Detail (Alternate 2) Scale: 3" = 1'-0"3
Non-Removable Curb Flashing Detail (Alternate 2)Scale: 3" = 1'-0"4
SELF-FLASHING UNIT
ADDITIONAL WOOD BLOCKING,IF REQUIRED (TO ACHIEVE AN 8"MIN. FLASHING HEIGHT)
GROMMETTED FASTENERS 12"O.C.
COUNTERFLASHING INSTALLEDBEHIND FLANGE
FLASHING TO ACCEPTABLESUBSTRATE
SPECIFIED SECUREMENT
HOT-AIR WELD60 MIL PVC MEMBRANE
COVER BOARD, ADHERED
TWO LAYERS OF 212"
POLYISOCYANURATEINSULATION, ADHERED
EXISTING 3" INSULATION TOREMAIN
AIR / VAPOR BARRIER
SUBSTRATE BOARDMECHANICALLY ATTACHED TOMETAL DECK
EXISTING METAL ROOF DECK
60 MIL PVC MEMBRANE
COVER BOARD, ADHERED
TWO LAYERS OF 212"
POLYISOCYANURATEINSULATION, ADHERED
AIR / VAPOR BARRIER
SUBSTRATE BOARDMECHANICALLY ATTACHEDTO METAL DECK
EXISTING METAL ROOF DECK
NON-REMOVABLE UNIT
GROMMETTED FASTENERS 12"O.C.
COUNTERFLASHING INSTALLEDBEHIND FLANGE
FLASHING TO ACCEPTABLESUBSTRATE
SPECIFIED SECUREMENT
HOT-AIR WELD
Pipe Flashing Detail (Alternate 2) Scale: 3" = 1'-0"5 Plumbing Vent Detail (Alternate 2)
Scale: 3" = 1'-0"6
12" COVER BOARD, ADHERED
60 MIL PVC MEMBRANE
COVER BOARD, ADHERED
TWO LAYERS OF 212"
POLYISOCYANURATEINSULATION, ADHERED
AIR / VAPOR BARRIER
SUBSTRATE BOARDMECHANICALLY ATTACHEDTO METAL DECK
EXISTING METALROOF DECK
PRE-MOLDED PVC PIPE BOOT
STAINLESS STEEL HOSE CLAMP
SEALANT AT TOP EDGE
PLUMBING VENT PENETRATION
8" M
IN.
1" M
IN.
60 MIL PVC MEMBRANE
COVER BOARD, ADHERED
TWO LAYERS OF 212"
POLYISOCYANURATEINSULATION, ADHERED
AIR / VAPOR BARRIER
SUBSTRATE BOARDMECHANICALLY ATTACHEDTO METAL DECK
EXISTING METAL ROOF DECK
8" M
IN.
PVC FLASHING MEMBRANE
STAINLESS STEEL HOSE CLAMP
SEALANT AT TOP EDGE
PIPE PENETRATION
PVC BASE FLASHING
MECHANICALLY FASTENMEMBRANE AT PENETRATION MECHANICALLY FASTEN
MEMBRANE AT PENETRATION
60 MIL PVC MEMBRANE
COVER BOARD, ADHERED
TWO LAYERS OF 212"
POLYISOCYANURATEINSULATION, ADHERED
AIR / VAPOR BARRIER
SUBSTRATE BOARDMECHANICALLY ATTACHEDTO METAL DECK
EXISTING METAL ROOF DECK
CAST IRON DRAIN STRAINER
SEALANT UNDER MEMBRANEAT CLAMPING RING
CLAMPING RING
MANUFACTURER'S REQUIREDSECUREMENT
PVC MEMBRANE FLASHING
TAPERED INSULATIONIN SUMP
Translucent Panel
Details
A-5.0
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
Wall Head DetailScale: 6" = 1'-0"1
Skylight Sill DetailScale: 3" = 1'-0"2
2 3 4" TRANSLUCENT PANELSYSTEM
TRANSLUCENT PANELFLASHING BY PANELMANUFACTURER
SEALANT AND BACKERROD WITH CORD WEEPSAT 24" O.C.
8" M
IN.
12" PLASTIC SHIMS
SET IN FULL BED OFSILICONE SEALANT
NEW 0.032" PREFINISHEDALUMINUM TRIM
NEW TREATED WOODBLOCKING. FASTEN TOSTEEL BEAM.
EXISTING STEEL BEAM TOREMAIN
SEMI-RIGID INSULATION
SLIP SHEET (DASHED)
NEW BATTEN SEAMROOF SYSTEM
EXISTING INSULATIONAND METAL DECK TOREMAIN
NEW PLYWOOD
NEW RIGIDINSULATION
PREFINISHED ALUMINUMCLOSURE 3" WIDE WITH 14"UPTURNED LEG
UNDERLAYMENTMEMBRANE SEAL TOCLOSURE AT BACK LEG
A-5.1
1 & 2
A-5.1
4
A-5.0
1
Skylight Head DetailScale: 3" = 1'-0"3
NEW 2" THICK SEMI-RIGIDINSULATION
NEW SHEATHING
NEW HORIZONTAL FURRING
NEW PREFINISHEDALUMINUMCOUNTERFLASHING
NEW .040" PREFINISHEDFLASHING WITH RECEIVER.STRIP IN WITH AIR BARRIERMEMBRANE.
NEW METAL PANEL SYSTEM
NEW FLASHINGMEMBRANE
NEW CONTINUOUSALUMINUM CLEAT
NEW SEALANT ANDBACKER ROD WITHCORD WEEPS AT 24"O.C.
234" TRANSLUCENT
PANEL SYSTEM
14" PLASTIC SHIMS
NEW PREFINISHEDALUMINUM TRIM
NEW WOODBLOCKING, ANCHORAT 24" O.C.
NEW CONTINUOUSALUMINUM TRIM(TWO-PIECE)
2 3 4" TRANSLUCENT PANELSYSTEM
A-5.1
3
TRANSLUCENT PANELFLASHING BY PANELMANUFACTURER
NEW 0.040"PREFINISHED ALUMINUMCOUNTERFLASHING
UNDERLAYMENTMEMBRANE. SEAL TOCLOSURE AT BACK LEG.
PREFINISHED 0.032"ALUMINUM CLOSURE 3" WIDEWITH 14" UPTURNED LEG
2 3 4" TRANSLUCENT PANELSYSTEM
NEW TREATED WOODBLOCKING. FASTEN TOSTEEL PLATE.
12" PLASTIC SHIMS
SET IN FULL BED OFSILICONE SEALANT
AT INTERIOR
NEW TREATED WOODBLOCKING. FASTEN TOSTEEL BEAM.
NEW THERMAL CLIPS
WET SEAL PANELJOINT WITH SILICONE
1/2"
EXISTING STEEL PLATE TOREMAIN
NEW 0.032" PREFINISHEDALUMINUM TRIM
SEALANT WITH WEEPCORDS AT 24" O.C.
1/2"
FOAM/METAL CLOSURE.SEAL TO PANEL ANDPROVIDE 1 WEEP.
EXTEND "GUTTER" AT HIPRAFTERS OVER UPTURNEDLEG AT SILL FLASHING ANDBEND DOWN TO DRAIN
1/2"
3" M
IN.
FELT UNDERLAYMENT
Translucent Panel
Details
A-5.1
As Shown
1
A
1
2
2
3
3
4
4
5
5
B
C
D
E
A
B
C
D
E
©C
opyr
ight
201
8. A
ll rig
hts r
eser
ved.
No
part
of th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm o
r by
any
mea
ns w
ithou
tpe
rmis
sion
from
Wis
s, Ja
nney
, Els
tner
Ass
ocia
tes,
Inc.
(WJE
). W
JE d
iscl
aim
s any
resp
onsi
bilit
y fo
r its
una
utho
rized
use
.
Plot
ted:
9/1
7/20
18 4
:38
PM b
y C
haije
nkit,
Tan
ya
File
Nam
e: P
:\201
8\20
18.0
xxx\
2018
.077
2.0
- TR
IPH
AH
N C
ENTE
R R
OO
F R
EPLA
CEM
ENT
RFQ
(PS)
\Dra
win
gs\R
oof
Rep
lace
men
t.dw
g
DescriptionMark Date
Project No.
Date
Drawn
Checked
Scale
Sheet Title
Sheet No.
Triphahn Center
Roof Replacement
Hoffman Estates
Park District
Project
Client
Headquarters & Laboratories: Northbrook, IllinoisAtlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | DetroitHonolulu | Houston | Los Angeles | Minneapolis | New Haven | New York
Princeton | San Francisco | Seattle | Washington, D.C.
Wiss, Janney, Elstner Associates, Inc.
330 Pfingsten Road
Northbrook, Illinois 60062
847.272.7400 tel | 847.480.9534 fax
www.wje.com
ENGINEERSARCHITECTSMATERIALS SCIENTISTS
TC
1685 West Higgins Road
Hoffman Estates, IL 60169
Issued for Bid9.17.18
1685 West Higgins Road
Hoffman Estates, IL 60169
September 17, 2018
2018.0772
PS / RAW
Wall Jamb and Batten DetailScale: 6" = 1'-0"4
2 3/
4"
5/8"1 1/8" PANEL DIMENSION
Enlarged Wall Sill DetailScale: 6" = 1'-0"2
EXISTING STEEL STUDFRAMING. REPAIR ASNECESSARY. A/E TOINSPECT FRAMING AFTEREXISTING TRANSLUCENTPANELS ARE REMOVED TODETERMINE REPAIRSREQUIRED.
NEW 12" TYPE X GYPSUMSHEATHING
2" RIGID INSULATION.TAPE ALL JOINTS WITHFOIL TAPE.
NEW 0.040" PREFINISHEDALUMINUM SOFFITPANELS
S.S. CLIPS AT 16" O.C. (STAGGER)
SEALANT JOINT
2 3 4" TRANSLUCENTPANEL SYSTEM
FLASHING MEMBRANE
FILL WITH SEALANT
1" RIGID INSULATION.TAPE ALL JOINTS WITHFOIL TAPE.
NEW THROUGH-WALLFLASHING. FORMRECEIVER AT BOTTOMEDGE.
NEW AIR/MOISTUREBARRIER
NEW 0.040" PREFINISHEDALUMINUM PANELS.RIVET TO CLIPS WITHCOLOR MATCH RIVETS.
NEW CONTINUOUS S.S.TERMINATION CLOSURESET IN SEALANT
Wall Sill DetailScale: 3" = 1'-0"1
A-5.1
2
EXISTING STUDS AT 16" O.C.
NEW WOOD BLOCKING ASNECESSARY TO SUPPORTAIR BARRIER. INSTALLBETWEEN STOREFRONTCLIPS.
EXISTING STOREFRONTSYSTEM TO REMAIN
PREFORMED SILICONE TOSEAL AIR/MOISTUREBARRIER TO STOREFRONT
NEW AIR/MOISTURE BARRIER2 3 4" TRANSLUCENTPANEL SYSTEM
NEW 2" RIGID INSULATION
EXISTING STEEL STUDFRAMING. REPAIR ASNECESSARY. A/E TOINSPECT FRAMINGAFTER EXISTINGTRANSLUCENT PANELSARE REMOVED TODETERMINE REPAIRSREQUIRED.
11 1/2"
Wall Panel Lateral Anchorage DetailScale: 6" = 1'-0"3
COUNTERSUNKFASTENERS
2 3 4" TRANSLUCENTPANEL SYSTEM
CONTINUOUS SEALANT
CONTINUOUS 0.063"PREFINISHED ALUMINUMTRIM
CONTINUOUS WOODBLOCKING
PREFINISHED STEEL CLIPANGLES TO MATCHMULLION COLOR. DESIGNAND ANCHORAGE TO BEBY TRANSLUCENT PANELCONTRACTOR.
SEALANT
PREFINISHED ALUMINUMRIVETS
TRANSLUCENT PANELFLASHING (PREFINISHEDALUMINUM) BY PANELMANUFACTURER
1/2"
EXISTING STEEL ANGLETO REMAIN. CLEAN ANDPAINT
NEW SEALANT ANDBACKER ROD WITHCORD WEEPS AT 24" O.C.
NEW CONTINUOUS 1XBLOCKING
CONTINUOUS PLASTICSHIMS SET IN SEALANT.PROVIDE 14" GAPBETWEEN.
1/2"
1"
1 1/
2"
CUT 1" DEEPCONTINUOUS REGLETIN MASONRY FORCLOSURE
NEW 0.040"PREFINISHEDALUMINUM CLOSURE
NEW SEALANT ANDBACKER ROD
NEW SEALANTJOINTS
5/8"WET SEAL HEAD AND JAMBSAT ALL PANELS WITHSILICONE. INSTALL AT 45°FLAT PROFILE.
Roof Batten DetailScale: 6" = 1'-0"6
Ridge DetailScale: 6" = 1'-0"5
SEALANT AND BACKER ROD
WET SEAL PANELS WITHSILICONE. INSTALL AT 45°FLAT PROFILE.
2 3 4" TRANSLUCENT PANELSYSTEM
PREFINISHED ALUMINUM"GUTTER" WITH HEMMEDEDGES TURNED UP 14"
NEW SEALANT JOINTS (TYP.)
NEW PREFINISHEDALUMINUM TRIM
NEW CONTINUOUS WOODBLOCKING. ANCHOR TOSTEEL BEAM.
14" CONTINUOUS PLASTIC
SHIMS SET IN SEALANT
CONTINUOUS SEALANT
2 3/
4"
EXISTING STEEL BEAM
3"
NEW 12" TYPE X GYPSUMSHEATHING
FILL SPACE AT END OFFLOOR WITH SEMI-RIGIDINSULATION
EXISTING MEZZANINEFLOOR. VERIFYCONSTRUCTION IN FIELD.
1/2"