Page 1: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

1

Counterflow Energy Recovery Ventilator

Quality Engineering Solutions

Energy Recovery Ventilator

www.dunnair.com.au

Page 2: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

2 www.dunnair.com.au

Quality Engineering Solutions

Dunnair Quality Engineering SolutionsDunnair is now firmly positioned as a leading supplier to the air conditioning industry.

The name Dunnair is synonymous with high quality products in the commercial air-conditioning industry. Beginning with Dunn Air Conditioning in 1961 and more recently, Dunnair International and Dunnair Australia, the company continues to be a leading importer and supplier of air-conditioning brands for the Australian market.

In 1994, the company was bought by Multistack and renamed Dunnair International. In 2004, Ernest Ugazio acquired the sales and subsequently state service department of Dunnair. This led to the company being divided into separate entities: Dunnair International and Dunnair Australia, the former focused on Multistack Chiller sales and spare parts; while the latter began design and development of a split ducted and rooftop packaged range that was manufactured in China.

The CHILLEDFLOW Fan Coil Units shown in this brochure are part of Dunnair’s range of high quality units for every application. Dunnair has also become the first choice when individual engineering solutions are required. Fast-moving and responsive, Dunnair supplies made-to-measure HVAC solutions to a growing number of high profile developments across Australia.

Dunnair research and development plus a strict quality control program have been fundamental to our growth, success and reputation. Dunnair units are manufactured in accordance with strict quality control standards and are MEPS rated and developed for Australian conditions.

Range: Dunnair’s two modern factories manufacture 16 separate product lines and some 600 different models. Dunnair can supply most products the HVAC industry requires. This new product line of CHILLEDFLOW Fan Coil Units is proof that the company is working continuously to improve its product range and the efficiency of its products.

Specialised Solutions: Dunnair will engineer and manufacture equipment to suit the application and building design. No challenge will go unaccepted. We will design and make special products as required for the building, mining, transport and maritime industry. We employ mechanical engineers in all sales offices in Australia. Their role is dedicated to supporting designers to achieve their goals.

Our promise to the system designers is: “Tell us what you need and we will work with you to deliver”.

With a head office in Melbourne, Dunnair has offices in New South Wales, Queensland, South Australia, Western Australia and Tasmania.Dunnair maintains a dedicated engineering and sales support staff waiting to assist you with technical and product information and provide valuable solutions for your project.

Dunnair will design, build and deliver HVAC equipment to meet the most stringent specifications and difficult applications.

Page 3: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

3

CounterFlow Energy Recovery VentilatorThe newly released CounterFlow Energy Recovery Ventilator series is a product that implements “heat recovery” technology by combining both heat exchanger and ventilator in the one unit.

With heat recovery, fresh outdoor air is treated by the exhausted indoor air via the heat exchanger. Treated means that the incoming fresh air stream flows counter to the outgoing exhaust air through the heat exchanger – the incoming air picks up energy via the heat exchanger from the exhaust air (see Figure 1).

Put simply: In summer, hot outdoor air will become “cooler” when entering the building and vice versa in winter. Energy consumption of a heating/cooling system of building will be greatly reduced as less energy will be used to cool down or heat incoming fresh air. As a result, optimal indoor air can be maintained at a lower cost.

Counterflow units are capable of achieving 70% energy recovery, making them ideal for using in commercial and domestic buildings to reduce running cost, achieve higher energy star rating and give the occupiers a quality working environment.

• Effective ventilation – Total Fresh air supply

• High efficiency energy recovery over 70%

• Low noise – silent operation

• Filters can be fitted to suit different applications

• Easy access for maintenance

• Supply airflow from 80 (L/s) to 5000 (L/s)

Page 4: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

4 www.dunnair.com.au

Working Principle

Fan Blower

Fresh Air 27̊ C

Return Air 24˚COutdoor Air 35˚C

Exhaust Air 31̊ C

Plate heat exchanger

core: Plan view

Fan Blower

Dunnair’s CounterFlow Energy Recovery Ventilator features:• Ceiling Type

• Ceiling Slim Type

• Ceiling Type with coil

• Vertical Type

• Horizontal Type

Air flow range from 80 l/sec to 5000 l/sec.

For more information, please go to www.dunnair.com.au or contact your local Dunnair sales office.

Figure 1

Page 5: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

5

Counterflow Energy Recovery Ventilator

Plate Heat Exchanger Core – how heat is exchanged

Indoor

Heat Exchanger

SA

RA

OA

EAOutdoor

(total heat exchanger)

A heat sensing exchanger can be provided as an option.

Please contact our local Dunnair sales office for support.

The Core of a heat exchanger is formed by plates of specially made paper, chemically treated on the surface, called heat transfer clapboard. The corrugated plates and flat plates are placed staggered against each other, glued together to form a cube shape. Such structure enables the Core to have greater capacity of heat transfer and moisture permeability. When there exist differences of air temperature and partial vapour pressure in any two sides of the Core, heat transfer and moisture transfer will be triggered. Thus the total heat exchange process starts.

Page 6: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

6 www.dunnair.com.au

Selection Guide1. Select different installation types of fresh air system based on building construction. According to various site conditions, air return

positions of our Counterflow Energy Recovery Ventilator series products can be adjusted to simplify the installation processes .

How to Read the Model Number

LPCM–80–T(S):

Product type: Low Profile Ceiling Mounted Energy Recovery Ventilator

Air Volume calculate as: 80 L/S

Heat Exchanger type: T: Total Heat Exchanger S: Sensible Heat Exchanger

SCM (C)–40–T(S):

Product type: SCM: Standard Ceiling Mounted Energy Recovery Ventilator SCMC: Standard Ceiling Mounted Energy Recovery Ventilator With Coil

Air Volume calculate as: 40 x 10 = 400 L/S

Heat Exchanger type: T: Total Heat Exchanger S: Sensible Heat Exchanger

HCV (H)–11–T(S):

Product type: HCV: High Capacity Floor Standing Vertical Type Energy Recovery Ventilator HCH: High Capacity Floor Standing Horizontal Type Energy Recovery Ventilator

Air Volume calculate as: 11 x 100 = 1100 L/S

Heat Exchanger type: T: Total Heat Exchanger S: Sensible Heat Exchanger

2. Select suitable fresh air volume based on room type, room area and number of occupiers

3. Select model and number of equipments based on fresh air volume required

Room TypeNormal

SickroomGymnasium

Theaters and Department

StoreOffice

Internet Bar

Dining Room

Function Room

Guest Room

Meeting Room

Fresh Air Volume per person q(l/s) 1.5 – 3.0 0.5– 2.0 0.5 –1.5 2.0 – 4.5 11.0 – 27.5 5.5 –14.0 16.5 – 39.0 8.0 – 21.0 14.0 – 34.5

Fresh Air Circulation Turnover n(times/h) 1.0–2.5 0.5–1.5 1.0–2.5 1.5–4.0 2.5–6.2 1.0–3.4 3.5–8 1.8–4.5 3.1–7.6

Before choosing fresh air volume needed for the room, other factors such as room space and number of occupiers in that room also need to to be considered. Calculate the fresh air volume separately based on “Fresh Air Volume per person” and “Fresh Air Circulation Turnover” respectively in the above table, and take the greater value from the two results as your key selection value .

Example

Meeting room area: S = 40 (m2), net height: H = 4 (m), occupiers: N = 20 (person), if calculation is based on fresh air volume per person, take q =20 then the fresh air volume required in this room is: Q1 = N x q=20 x 20 = 400 (l/s)

If calculation is based on fresh air ventilate turnover, take n = 7 (times/h).

then the fresh air volume is Q2 = n x S x H = 7 x 40 x 4 = 1120 (m3/h )=311 (l/s).

Because Q1 > Q2, Q1, (400 l /s) shall be selected as the key criterion of system selection.

Page 7: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

7

Counterflow Energy Recovery Ventilator

Low profile ceiling mounted model

Specifications and Performance

ModelAir

Flow Rate

External Static

Pressure

Heat Exchanger Dimensions

Supply Fan Model

and Fan Motor

Exhaust Fan Model

and Fan Motor

Summer WinterHX

ResistancePower Supply

LPCM L/S PaL x W x H x

CH* mm

Fan Model (motor size)

kW

Fan Model (motor size)

kW

Temp.efficiency

%

Enthalpy efficiency

%

Temp.efficiency

%

Enthalpy efficiency

%Pa V/Ph/Hz

80 83 70200 x 200 x

560 x 3.2

KDF 143/95RD (0.022-4P)

KDF 143/95RD (0.022-4P)

72.4 74.4 71.6 62 34 240V/1PH/50HZ

110 111 70200 x 200 x

710 x 3.2

KDF 143/166RD

(0.12-4P)

KDF 143/166RD

(0.12-4P)71.7 73.6 70.8 61.1 35 240V/1PH/50HZ

170 167 110250 x 250 x

710 x 3.4KDF 1.7RD (0.075-4p)

KDF 1.7RD (0.075-4p)

72.4 74.4 71.6 61.9 48 240V/1PH/50HZ

230 222 160250 x 250 x

810 x 3.2SYZ7-7I (0.15-4p)

SYZ7-7I (0.15-4p)

70 72.2 68.9 58.2 66 240V/1PH/50HZ

280 278 170250 x 250 x

860 x 3.2SYZ7-7I (0.15-4p)

SYZ7-7I (0.15-4p)

68.4 70.7 67.3 56.3 73 240V/1PH/51HZ

350 347 160250 x 250 x

985 x 3.2SYZ7-7I (0.2-4p)

SYZ7-7I (0.2-4p)

67.8 70.2 66.8 55.8 75 240V/1PH/52HZ

400 417 150250 x 250 x 1160 x 3.2

SYZ7-7I (0.2-4p)

SYZ7-7I (0.2-4p)

67.5 69.9 66.5 55.3 76 240V/1PH/53HZ

Summer:Freshair35˚C/21˚C26RH% Exhuastair24˚C/17˚C50RH% Winter:Freshair3˚C/50RH% Exhuastair24˚C/RH50%

W C

B

Access Point Access Point

Filter Direction

Access Point

Access Point

Filter Direction

15

Air Outlet 1 Air Outlet 2

Air Inlet 2 Air Inlet 1

AH

A

L80 80

A A

W

Wiring Box

Dimensions

ModelSize

L W H A B C

LPCM80 950 600 300 150 990 525

LPCM110 950 750 300 200 990 675

LPCM170 1150 750 400 200 1190 675

LPCM230 1150 850 400 300 1190 725

LPCM280 1150 900 400 300 1190 775

LPCM350 1150 1025 400 300 1190 950

LPCM400 1150 1200 400 300 1190 1125

*CH: Corrigation Height

HeatExchangerDimensions

L x W x H xCH* mm

Page 8: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

8 www.dunnair.com.au

Low profile ceiling mounted model

Fan Curves

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

110

90

70

50

30

30 50 7040 60 80 90

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

180

170

160

150

140

100 250150 200 300

Nominal Air Flow

EXTE

RN

AL

STAT

IC P

RES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

130

110

120

100

90

80

60 16014010080 120 180 200

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

180

170

150

130

160

140

120

150 200 300250 350 450400

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

80

60

70

50

40

30

40 10060 80 120 140

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

200

180

160

140

120

130 180 280230 330 380

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

220

180

200

160

140

120

60 160110 210 260

Nominal Air Flow

LPCM80

LPCM170

LPCM280

LPCM400

LPCM110

LPCM230

LPCM350

Page 9: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

9

Counterflow Energy Recovery Ventilator

Low profile ceiling mounted model

Sound Pressure Curves*

Frequency

Model

LPCM80 LPCM110 LPCM170 LPCM230 LPCM280 LPCM350 LPCM400

A Class: 43.5 (dB)

B Class: 43.3 (dB)

B Class:46.1 (dB)

B Class:56 (dB)

D Class:57.5 (dB)

C Class:57.7 (dB)

E Class:60.5 (dB)

125Hz 41 46 47 40.4 39.9 38.1 38.2

250Hz 33 45.4 46 48.3 48.6 48.4 48.8

500Hz 29 42.6 43 46.8 48.3 48.7 51.4

1kHz 28 41 41 50.8 52.4 53.2 56.2

2kHz 26 37 38 48.1 49.9 50.8 53.6

4kHz 17 29 30 47.4 50 49.9 52.9

8kHz 14 24 25 45.2 46.5 43.3 47.3

60

DEC

IBEL

(dB

)

50

30

10

40

20

FREQUENCY

125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

*Return Fans and Exhaust Fans are the same models.

Page 10: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

10 www.dunnair.com.au

Standard ceiling mounted model

Air Outlet 1

Air Inlet 2

35

35

W

Wiring Box

F

Air Outlet 2

Air Inlet 1

Wiring Box

Access Point

Filter Direction

15E

Access Point Access Point Access Point

Filter Direction

H

L60 60

D B

W

C

A

Air Outlet 1

Air Inlet 2

Wiring Box

50

50

W

Access Point Access Point Access Point

Filter Direction

Access Point

Filter Direction

15E

L60 60

50

D

C

BA

W

F

Air Outlet 2

Air Inlet 1

Wiring Box

H

Dimensions

ModelSize

L W H A B C D E F

SCM40 1400 1200 550 400 400 281 273 1342 1240

SCM60 1400 1400 550 400 400 258 246 1342 1440

SCM70 1400 1500 550 500 400 300 273 1342 1540

SCM80 1400 1900 550 600 400 300 272 1342 1940

Dimensions

ModelSize

L W H A B C D E F

SCM110 1850 1500 750 600 550 375 375 1800 1550

SCM140 1850 1700 750 600 550 431 375 1800 1750

SCM170 2050 1800 850 800 550 431 375 2000 1850

SCM220 2050 2100 850 800 550 419 419 2000 2150

*Flange Frame width: 50mm.

*Flange Frame width: 50mm.

Page 11: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

11

Counterflow Energy Recovery Ventilator

Standard ceiling mounted model

Specifications and Performance

ModelAir

Flow Rate

External Static

Pressure

Heat Exchanger Dimensions

Supply Fan Model

and Fan Motor

Exhaust Fan Model

and Fan Motor

Summer WinterHX

ResistancePower Supply

SCM L/S PaL x W x H x CH*

mm

Fan Model (motor size)

kW

Fan Model (motor size)

kW

Temp.efficiency

%

Enthalpy efficiency

%

Temp.efficiency

%

Enthalpy efficiency

%Pa V/Ph/Hz

40 444 140250 x 250 x 1140

x 3.2SYB250I (0.32-6p)

SYB250I (0.32-6p)

66 68.4 65 54.1 83 415V/3/50

60 556 160250 x 250 x 1340

x 3.2SYB225II (0.45-4P)

SYB225II (0.45-4P)

65 67.3 63.8 52.4 89 415V/3/50

70 695 250250 x 250 x 1440

x 3.0SYB225III (0.45-4P)

SYB225III (0.45-4P)

65 67.4 63.8 51.8 118 415V/3/50

80 833 260250 x 250 x 1840

x 3.0SYB250II (0.8-4p)

SYB250II (0.8-4p)

66.1 68.6 65.1 53.1 110 415V/3/50

110 1111 2803350 x 350 x 1440

x 3.2SYB355I (1.1-6p)

SYB355I (1.1-6p)

66.1 68.5 65 53.6 145 415V/3/50

140 1389 250350 x 350 x 1640

x 3.2SYB355II (1.5-6p)

SYB355II (1.5-6p)

64.3 66.8 63.6 51.9 160 415V/3/50

170 1667 230400 x 400 x 1740

x 3.2SYB355II (1.5-6p)

SYB355II (1.5-6p)

67.1 69.4 66 54.8 170 415V/3/50

220 2222 230400 x 400 x 2040

x 3.2SYB400I (2.2-6p)

SYB400I (2.2-6p)

64.8 67.1 65.1 58.1 195 415V/3/50

Summer:Freshair35˚C/21˚C26RH% Exhuastair24˚C/17˚C50RH% Winter:Freshair3˚C/50RH% Exhuastair24˚C/RH50%

*CH: Corrigation Height

HeatExchangerDimensions

L x W x H xCH* mm

250 x 250 x 1140 x 3.2

250 x 250 x 1340 x 3.2

250 x 250 x 1440 x 3.0

250 x 250 x 1840 x 3.0

350 x 350 x 1440 x 3.2

350 x 350 x 1640 x 3.2

400 x400 x 1740 x 3.2

400 x 400 x 2040 x 3.2

Page 12: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

12 www.dunnair.com.au

Fan Curves

EXTE

RN

AL

STAT

IC P

RES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

180

140

100

60

20

350 400 450 500 550 600

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1050 1100 1150 1200 1250 1300

Nominal Air Flow300

280

260

240

220

EXTE

RN

AL

STAT

IC P

RES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

500 550 600 650 700 750

Nominal Air Flow320

300

280

260

240

220

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

300

260

220

180

140

1400 16001500 1700 1800 1900 2000

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

450 500 550 600 650 700

Nominal Air Flow200

160

120

80

40

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1350 14501400 1500 1550 1600 1650 1700

Nominal Air Flow270

250

230

210

190

170

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

650 700 750 800 850 950900 1000

Nominal Air Flow340

300

260

220

180

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1700 19001800 2000 2100 2200 2300 2400

Nominal Air Flow400

350

300

250

200

150

SCM40

SCM70

SCM110

SCM170

SCM60

SCM80

SCM140

SCM220

Standard ceiling mounted model

Page 13: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

13

Counterflow Energy Recovery Ventilator

Standard ceiling mounted model

Sound Pressure Curves

Frequency

Model

SCM40 SCM60 SCM70 SCM80 SCM110 SCM140 SCM170 SCM220

A Class: 57.3 (dB)

C Class: 62 (dB)

E Class:63.2 (dB)

D Class:64.4 (dB)

A Class:69.4 (dB)

A Class:72 (dB)

C Class:73.8 (dB)

E Class:75.2 (dB)

125Hz 41.5 48.3 47.2 50.2 53.9 58.1 64.4 67.5

250Hz 47.9 54.7 54.1 57.8 56.7 61 61.7 62.9

500Hz 49.1 53 54.1 55.8 61.8 62.2 64.6 64.6

1kHz 54.1 56 57.9 58.5 65.2 67 68.7 70.4

2kHz 48.8 55.5 57.2 57.2 61.7 64.4 67.6 68.5

4kHz 45.9 53.3 55.4 55.4 61.1 65.7 65.1 66.3

8kHz 35 43.5 47.2 48 54.6 59.3 57.5 57.7

80

DEC

IBEL

(dB

)

70

50

30

60

40

FREQUENCY

125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

*Return Fans and Exhaust Fans are the same models.

Page 14: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

14 www.dunnair.com.au

Standard ceiling mounted with coil model

Access Point Access Point Access Point

Filter Direction

35

35

WF

Air Outlet 1

Air Inlet 2

Wiring Box

Access Point

Filter Direction

Air Outlet 2

Air Inlet 1

Wiring Box

15E

H

L60 60

H A

W

G B

ZG 1 1/2”

ZG 1 1/2”

ZG 1”

Access Point Access Point Access Point

Filter Direction

80

80

WF

Air Outlet 1

Air Inlet 2

Wiring Box

Access Point

Filter Direction

Air Outlet 2

Air Inlet 1

Wiring Box

20E

H

L60 60

ZG 1 1/2”

ZG 1 1/2”

ZG 1”

H A

W

G B

Dimensions

ModelSize

L W H A B C D E F G H

SCMC40 1850 1200 615 400 400 281 273 1792 1240 281 273

SCMC60 1850 1400 615 400 400 258 246 1792 1440 300 273

SCMC70 1850 1500 615 500 400 300 273 1792 1540 281 273

SCMC80 1850 1900 615 600 400 300 272 1792 1940 356 304

Dimensions

ModelSize

L W H A B C D E F G H

SCMC110 2300 1500 870 600 500 375 375 2250 1600 419 419

SCMC140 2300 1700 870 600 500 431 375 2250 1800 460 419

SCMC170 2500 1800 970 800 500 431 375 2450 1900 460 419

SCMC220 2500 2100 970 800 500 419 419 2450 2200 460 419

*Flange Frame width: 50mm.

*Flange Frame width: 50mm.

Page 15: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

15

Counterflow Energy Recovery Ventilator

Standard ceiling mounted with coil model

Sound Pressure Curves – SupplyFan

Frequency

Model

SCMC40 SCMC60 SCMC70 SCMC80 SCMC110 SCMC140 SCMC170 SCMC220

A Class: 65.5 (dB)

B Class: 61.3 (dB)

C Class:64.6 (dB)

E Class:63 (dB)

A Class:70.3(dB)

B Class:67.2 (dB)

C Class:69.2 (dB)

E Class:73.5 (dB)

125Hz 45.3 49.3 45.9 43.5 61.5 57.3 61.5 59.9

250Hz 54.1 53.1 54.3 53.9 58.9 55.4 56.8 60.3

500Hz 56.4 52.1 55.6 57.1 61 57.2 58.5 63.7

1kHz 61.3 55.6 60 57.5 66.3 62.8 64.3 68.9

2kHz 58.9 55.2 57.9 55.3 62.4 60.7 62.5 67.9

4kHz 57.9 52.6 56.9 54.6 60.5 58.5 60.2 65.5

8kHz 50.6 43.4 49.2 47.2 50.6 49.5 51.7 58

70

DEC

IBEL

(dB

)

60

50

40

65

55

45

FREQUENCY

125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

Page 16: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

16 www.dunnair.com.au

Standard ceiling mounted with coil model

Specifications and Performance

Model Air Flow RateExternal Static

PressureHeat Exchanger

Dimensions Exhaust Fan Model and

Fan MotorSupply Fan Model and

Fan MotorCoil Summer Winter HXResistance Power Supply

SCMC L/S Pa L x W x H x CH* mmFan Model

(motor size) kWFan Model

(motor size) kWCooling capacity

kWWater flow L/S

Heating capacity kW

Water flow L/STemp.

efficiency %Enthalpy

efficiency %Temp.

efficiency %Enthalpy

efficiency %Pa V/Ph/Hz

40 444 140 250 x 250 x 1140 x 3.2 SYB250I (0.32-6p) SYB250I (0.45-4p) 12.2 0.49 33.47 0.41 66 68.4 65 54.1 83 415V/3/50

60 556 160 250 x 250 x 1340 x 3.2 SYB225II (0.45-4P) SYB225III (0.45-4P) 15.68 0.63 42.18 0.52 65 67.3 63.8 52.4 89 415V/3/50

70 695 250 250 x 250 x 1440 x 3.0 SYB225III (0.45-4P) SYB250I (0.8-4P) 18.96 0.76 51.4 0.65 65 67.4 63.8 51.8 118 415V/3/50

80 833 260 250 x 250 x 1840 x 3.0 SYB250II (0.8-4p) SYB280II (0.8-4p) 23.53 0.94 63.05 0.8 66.1 68.6 65.1 53.1 110 415V/3/50

110 1111 280 350 x 350 x 1440 x 3.2 SYB355I (1.1-6p) SYB400I (2.2-6p) 29.01 1.16 74.74 0.95 66.1 68.5 65 53.6 145 415V/3/50

140 1389 250 350 x 350 x 1640 x 3.2 SYB355II (1.5-6p) SYB400II (1.8-6p) 36.51 1.45 92.57 1.18 64.3 66.8 63.6 51.9 160 415V/3/50

170 1667 230 400 x 400 x 1740 x 3.2 SYB355II (1.5-6p) SYB400II (1.8-6p) 44.69 1.78 112.24 1.42 67.1 69.4 66 54.8 170 415V/3/50

220 2222 230 400 x 400 x 2040 x 3.2 SYB400I (2.2-6p) SYB400II (2.2-6p) 59.03 2.35 146.63 1.86 64.8 67.1 65.1 58.1 195 415V/3/50

Summer:Freshair35˚C/21˚C26RH% Exhuastair24˚C/17˚C50RH% Winter:Freshair3˚C/50RH% Exhuastair24˚C/RH50%

Fan Curves

EXTE

RN

AL

STAT

IC P

RES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

180

140

100

60

20

350 400 450 500 550 600

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

500 600550 650 700 750

Nominal Air Flow320

300

280

260

240

220

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

450 550500 600 650 700

Nominal Air Flow210

190

170

150

130

110

90

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

650 800750 850 900 950

Nominal Air Flow

700

320

300

280

260

240

220

200

SCMC40

SCMC70

SCMC60

SCMC80

*CH: Corrigation Height

HeatExchangerDimensions

L x W x H xCH* mm

250 x 250 x 1140 x 3.2

250 x 250 x 1340 x 3.2

250 x 250 x 1440 x 3.0

250 x 250 x 1840 x 3.0

350 x 350 x 1440 x 3.2

350 x 350 x 1640 x 3.2

400 x 400 x 1740 x 3.2

400 x 400 x 2040 x 3.2

Page 17: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

17

Counterflow Energy Recovery Ventilator

Specifications and Performance

Model Air Flow RateExternal Static

PressureHeat Exchanger

Dimensions Exhaust Fan Model and

Fan MotorSupply Fan Model and

Fan MotorCoil Summer Winter HXResistance Power Supply

SCMC L/S Pa L x W x H x CH* mmFan Model

(motor size) kWFan Model

(motor size) kWCooling capacity

kWWater flow L/S

Heating capacity kW

Water flow L/STemp.

efficiency %Enthalpy

efficiency %Temp.

efficiency %Enthalpy

efficiency %Pa V/Ph/Hz

40 444 140 250 x 250 x 1140 x 3.2 SYB250I (0.32-6p) SYB250I (0.45-4p) 12.2 0.49 33.47 0.41 66 68.4 65 54.1 83 415V/3/50

60 556 160 250 x 250 x 1340 x 3.2 SYB225II (0.45-4P) SYB225III (0.45-4P) 15.68 0.63 42.18 0.52 65 67.3 63.8 52.4 89 415V/3/50

70 695 250 250 x 250 x 1440 x 3.0 SYB225III (0.45-4P) SYB250I (0.8-4P) 18.96 0.76 51.4 0.65 65 67.4 63.8 51.8 118 415V/3/50

80 833 260 250 x 250 x 1840 x 3.0 SYB250II (0.8-4p) SYB280II (0.8-4p) 23.53 0.94 63.05 0.8 66.1 68.6 65.1 53.1 110 415V/3/50

110 1111 280 350 x 350 x 1440 x 3.2 SYB355I (1.1-6p) SYB400I (2.2-6p) 29.01 1.16 74.74 0.95 66.1 68.5 65 53.6 145 415V/3/50

140 1389 250 350 x 350 x 1640 x 3.2 SYB355II (1.5-6p) SYB400II (1.8-6p) 36.51 1.45 92.57 1.18 64.3 66.8 63.6 51.9 160 415V/3/50

170 1667 230 400 x 400 x 1740 x 3.2 SYB355II (1.5-6p) SYB400II (1.8-6p) 44.69 1.78 112.24 1.42 67.1 69.4 66 54.8 170 415V/3/50

220 2222 230 400 x 400 x 2040 x 3.2 SYB400I (2.2-6p) SYB400II (2.2-6p) 59.03 2.35 146.63 1.86 64.8 67.1 65.1 58.1 195 415V/3/50

Summer:Freshair35˚C/21˚C26RH% Exhuastair24˚C/17˚C50RH% Winter:Freshair3˚C/50RH% Exhuastair24˚C/RH50%

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

300

280

260

240

220

1050 1100 1150 1200 1250 1300

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

300

260

220

180

140

1300 15001400 1600 1700 1800 1900 2000

Nominal Air Flow

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1350 15001450 1550 1600 1650 1700

Nominal Air Flow

1400

260

240

220

200

180

160

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1700 21002000 2200 2300 2400

Nominal Air Flow

19001800

450

400

350

300

250

200

150

SCMC110

SCMC170

SCMC140

SCMC220

Page 18: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

18 www.dunnair.com.au

Standard ceiling mounted with coil model

Sound Pressure Curves – Exhaust Fan

Frequency

Model

SCMC40 SCMC60 SCMC70 SCMC80 SCMC110 SCMC140 SCMC170 SCMC220

A Class: 57.3 (dB)

C Class: 62 (dB)

E Class:63.2 (dB)

D Class:64.4 (dB)

A Class:69.4 (dB)

A Class:72 (dB)

C Class:73.8 (dB)

E Class:75.2 (dB)

125Hz 41.5 48.3 47.2 50.2 53.9 58.1 64.4 67.5

250Hz 47.9 54.7 54.1 57.8 56.7 61 61.7 62.9

500Hz 49.1 53 54.1 55.8 61.8 62.2 64.6 64.6

1kHz 54.1 56 57.9 58.5 65.2 67 68.7 70.4

2kHz 48.8 55.5 57.2 57.2 61.7 64.4 67.6 68.5

4kHz 45.9 53.3 55.4 55.4 61.1 65.7 65.1 66.3

8kHz 35 43.5 47.2 48 54.6 59.3 57.5 57.7

80

DEC

IBEL

(dB

)

70

50

30

60

40

FREQUENCY

125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

Page 19: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

19

Counterflow Energy Recovery Ventilator

High capacity vertical type

Specifications and Performance

ModelAir

Flow Rate

External Static

Pressure

Heat Exchanger Dimensions

Supply Fan Model

and Fan Motor

Exhaust Fan Model

and Fan Motor

Summer WinterHX

ResistancePower Supply

HCV L/S PaL x W x H x CH*

mm

Fan Model (motor size)

kW

Fan Model (motor size)

kW

Temp.efficiency

%

Enthalpy efficiency

%

Temp.efficiency

%

Enthalpy efficiency

%Pa V/Ph/Hz

11 1111 190500 x 500 x 790

x 3.2SYB355I (1.1-6P)

SYB355I (1.1-6P)

69.5 71.9 68.6 58.4 211 415V/3/50

14 1389 190600 x 600 x 790

x 3.5SYB355I (1.1-6P)

SYB355I (1.1-6P)

68.1 70.2 67 57.2 212 415V/3/50

17 1667 180600 x 600 x 950

x 3.5SYB355II (1.5-6p)

SYB355II (1.5-6p)

68.6 70.7 67.5 58 205 415V/3/50

22 2222 250750 x 750 x 1040

x 3.7SYB400I (2.2-6P)

SYB400I (2.2-6P)

69.9 71.9 68.8 59.8 215 415V/3/50

28 2778 230500 x 500 x 1990

x 3.2SYB400II

(3-6P)SYB400II

(3-6P)70.1 72.3 69 58.9 205 415V/3/50

33 3334 400600 x 600 x 1890

x 3.2SYB450II

(4-6P)SYB450II

(4-6P)70.6 72.8 69.5 59.5 268 415V/3/50

42 4167 400600 x 600 x 2370

x 3.2SYB500I

(6-6P)SYB500I

(6-6P)70.9 73.1 69.9 59.9 263 415V/3/50

50 5000 450600 x 600 x 2840

x 3.2SYB500II (7.5-6P)

SYB500II (7.5-6P)

70.9 73.1 69.9 59.9 263 415V/3/50

Summer:Freshair35˚C/21˚C26RH% Exhuastair24˚C/17˚C50RH% Winter:Freshair3˚C/50RH% Exhuastair24˚C/RH50%

Dimensions

ModelSize

L W H C D E F

HCV11 1250 850 1650 450 750 338 338

HCV14 1320 850 1800 485 750 375 375

HCV17 1320 1010 1800 485 910 375 431

HCV22 1420 1100 2100 500 1000 419 419

HCV28 960 2050 1900 450 1500 419 460

HCV33 1100 1950 2100 500 1500 469 530

HCV42 1100 2430 2150 500 2000 506 506

HCV50 1100 2900 2150 500 2500 506 0

H

50

ExF ExF

80

50 50

L

CxD CxD

Air Inlet 1Air Inlet 2

Air Outlet 1 Air Outlet 2

W

Wiring Box

F

E

W

C

D

C

D

*CH: Corrigation Height

*Flange Frame width: 50mm.

HeatExchangerDimensions

L x W x H xCH* mm

500 x 500 x 790 x 3.2

600 x 600 x 790 x 3.5

600 x 600 x 950 x 3.5

750 x 750 x 1040 x 3.7

500 x 500 x 1990 x 3.2

600 x 600 x 1890 x 3.2

600 x 600 x 2370 x 3.2

600 x 600 x 2840 x 3.2

Page 20: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

20 www.dunnair.com.au

High capacity vertical type

Fan Curves

EXTE

RN

AL

STAT

IC P

RES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1050 12501150 1300 1350 1400

Nominal Air Flow

12001100

250

200

150

100

50

HCV11

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1300 17001500 1800 1900 2000

Nominal Air Flow

1400 1600

300

250

200

150

100

HCV17

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

350

300

250

200

150

2300 2500 27002400 2600 2800 2900

Nominal Air FlowHCV28

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

3400 38003600 4000 4200 4400

Nominal Air Flow600

550

500

450

400

350

HCV42*

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1100 14001200 1500 1600

Nominal Air Flow

1300

300

250

200

150

100

HCV14

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

350

300

250

200

150

1800 2000 22001900 2100 2300 2400 2500

Nominal Air FlowHCV22

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

480

440

400

360

320

2700 3100 35002900 3300 3700

Nominal Air FlowHCV33*

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

600

560

520

480

440

4000 4400 48004200 4600 5000

Nominal Air FlowHCV50*

* Note: If lower ESP is required, re-selection of fans is possible, please contact with your local Dunnair sales office or agent.

Page 21: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

21

Counterflow Energy Recovery Ventilator

High capacity vertical type

Sound Pressure Curves

Frequency

Model

HCV11 HCV14 HCV17 HCV22 HCV28 HCV33 HCV42 HCV50

A Class: 69.4 (dB)

D Class: 73.7 (dB)

C Class:73.8 (dB)

E Class:75.2 (dB)

E Class:77 (dB)

F Class:76.1 (dB)

E Class:76.2 (dB)

F Class:78.9 (dB)

125Hz 53.9 55.5 64.4 67.5 68.9 56.7 60.4 65.2

250Hz 56.7 59 61.7 62.9 63.5 61.7 63.3 66.4

500Hz 61.8 65.5 64.6 64.6 66.5 70.9 71.8 69.2

1kHz 65.2 69.7 68.7 70.4 72.2 71.2 71.1 74.7

2kHz 61.7 67 67.6 68.5 70.7 69.1 67.9 73.3

4kHz 61.1 65.8 65.1 66.3 68.3 66.3 65.2 69.4

8kHz 54.6 58.7 57.5 57.7 60.3 59.3 58.5 62.3

80

DEC

IBEL

(dB

)

70

60

50

75

65

55

FREQUENCY

125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

*Return Fans and Exhaust Fans are the same models.

Page 22: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

22 www.dunnair.com.au

High capacity horizontal type

ExF

CxDW

Air Outlet 1

Air Inlet 2

ExF

CxD

Air Outlet 2

Air Inlet 1

L50 50 W80

H FE

C

D

Wiring Box

ExF

CxD

ExF

CxD

L

Air Outlet 1

Air Inlet 2

Air Outlet 2

Air Inlet 1

W L50 50 80

H

F

EC

D

Wiring Box

Dimensions

ModelSize

L W H C D E F

HCH11 1250 1560 930 400 750 338 338

HCH14 1400 1650 930 475 750 375 375

HCH17 1450 1730 1090 475 910 375 431

HCH22 1700 1870 1180 550 1000 419 419

Dimensions

ModelSize

L W H C D E F

HCH28 2340 1800 1580 600 1000 419 460

HCH33 2450 1900 1720 700 1000 469 530

HCH42 2650 1950 1860 700 1200 506 506

HCH50 2700 2200 1860 800 1250 506 600

*Flange Frame width: 50mm.

*Flange Frame width: 50mm.

Page 23: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

23

Counterflow Energy Recovery Ventilator

High capacity horizontal type

Specifications and Performance

ModelAir

Flow Rate

External Static

Pressure

Heat Exchanger Dimensions

Supply Fan Model

and Fan Motor

Exhaust Fan Model

and Fan Motor

Summer WinterHX

ResistancePower Supply

HCH L/S PaL x W x H x CH*

mm

No. of HX

Fan Model (motor size)

kW

Fan Model (motor size)

kW

Temp.efficiency

%

Enthalpy efficiency

%

Temp.efficiency

%

Enthalpy efficiency

%Pa V/Ph/Hz

11 1111 190500 x 500 x 790

x 3.2SYB355I (1.1-6P)

SYB355I (1.1-6P)

69.5 71.9 68.6 58.4 211 415V/3/50

14 1389 190600 x 600 x 790

x 3.5SYB355I (1.1-6P)

SYB355I (1.1-6P)

68.1 70.2 67 57.2 212 415V/3/50

17 1667 180600 x 600 x 950

x 3.5SYB355II (1.5-6p)

SYB355II (1.5-6p)

68.6 70.7 67.5 58 205 415V/3/50

22 2222 250750 x 750 x 1040

x 3.7SYB400I (2.2-6P)

SYB400I (2.2-6P)

69.9 71.9 68.8 59.8 215 415V/3/50

28 2778 300450 x 450 x 1740

x 3.2

2

SYB400II (3-6P)

SYB400II (3-6P)

72 74.1 71.2 64.3 131 415V/3/50

33 3334 500500 x 500 x 1840

x 3.2

2

SYB450II (4-6P)

SYB450II (4-6P)

73.3 75.3 72.4 65.8 142 415V/3/50

42 4167 500550 x 550 x 1890

x 3.2

2

SYB500I (6-6P)

SYB500I (6-6P)

73.2 75.2 72.4 65.7 167 415V/3/50

50 5000 550550 x 550 x 2140

x 3.2

2

SYB500II (7.5-6P)

SYB500II (7.5-6P)

73.1 75.1 65.5 59.9 169 415V/3/50

Summer:Freshair35˚C/21˚C26RH% Exhuastair24˚C/17˚C50RH% Winter:Freshair3˚C/50RH% Exhuastair24˚C/RH50%

*CH: Corrigation Height

HeatExchangerDimensions

L x W x H xCH* mm

500 x 500 x 790 x 3.2

600 x 600 x 790 x 3.5

600 x 600 x 950 x 3.5

750 x 750 x 1040 x 3.7

450 x 450 x 1740 x 3.2

450 x 450 x 1840 x 3.2

450 x 450 x 1840 x 3.2

450 x 450 x 1840 x 3.2

450 x 450 x 1840 x 3.2

450 x 450 x 1840 x 3.2

450 x 450 x 1840 x 3.2

Page 24: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

24 www.dunnair.com.au

Fan Curves

High capacity horizontal typeEX

TER

NA

L ST

ATIC

PR

ESSU

RE

(Pas

cals

)

AIR FLOW (l/s)

1050 12501150 1300 1350 1400

Nominal Air Flow

12001100

250

200

150

100

50

HCH11

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1300 17001500 1800 1900 2000

Nominal Air Flow

1400 1600

300

250

200

150

100

HCH17

EXTE

RN

AL

STAT

IC P

RES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

390

350

370

330

310

290

270

2300 2500 27002400 2600 2800 2900

Nominal Air FlowHCH28

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

3400 38003600 4000 4200 4400

Nominal Air Flow700

650

600

550

500

450

HCH42*

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

1100 14001200 1500 1600

Nominal Air Flow

1300

300

250

200

150

100

HCH14

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

350

300

250

200

150

1800 2000 22001900 2100 2300 2400 2500

Nominal Air FlowHCH22

EXTE

RN

AL

STA

TIC

PRES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

570

550

530

510

490

2700 2900 33003100 3500 3700

Nominal Air FlowHCH33*

EXTE

RN

AL

STAT

IC P

RES

SUR

E (P

asca

ls)

AIR FLOW (l/s)

640

600

620

580

560

540

4000 4400 48004200 4600 5000

Nominal Air FlowHCH50*

* Note: If lower ESP is required, re-selection of fans is possible, please contact with your local Dunnair sales office or agent.

Page 25: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

25

Counterflow Energy Recovery Ventilator

High capacity horizontal type

Sound Pressure Curves

Frequency

Model

HCH11 HCH14 HCH17 HCH22 HCH28 HCH33 HCH42 HCH50

A Class: 69.4 (dB)

D Class: 73.7 (dB)

C Class:73.8 (dB)

E Class:75.2 (dB)

E Class:77 (dB)

F Class:76.1 (dB)

E Class:76.2 (dB)

F Class:78.9 (dB)

125Hz 53.9 55.5 64.4 67.5 68.9 56.7 60.4 65.2

250Hz 56.7 59 61.7 62.9 63.5 61.7 63.3 66.4

500Hz 61.8 65.5 64.6 64.6 66.5 70.9 71.8 69.2

1kHz 65.2 69.7 68.7 70.4 72.2 71.2 71.1 74.7

2kHz 61.7 67 67.6 68.5 70.7 69.1 67.9 73.3

4kHz 61.1 65.8 65.1 66.3 68.3 66.3 65.2 69.4

8kHz 54.6 58.7 57.5 57.7 60.3 59.3 58.5 62.3

80

DEC

IBEL

(dB

)

70

60

50

75

65

55

FREQUENCY

125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

*Return Fans and Exhaust Fans are the same models.

Page 26: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

26 www.dunnair.com.au

LPCM models

Three phase five line475V 50HZ 3P

AQF

KM1 KM2

Power Supply240V 50HZ 1P

LQF

KA1

KA2KA3

KA4

KA6KA5

EM1 EM2

KA1

NRLRMRHNRLRMRH

32

1

1L

N

3

The Controller

N

1 2 3 4 5 6 7 8 9 10 11 PE

N U1 V1 W1 U2 V2 W2

EM1 EM2

1 2 3

2

1

N N

4 5 6 7

KA2 KA3 KA4 KA5 KA6

FU

N

E

U1 V1 W1 U2 V2W2

EM1 EM2

FR1 FR2

PRF

L1 FU

Signal controlfrom the controller

Signal controlfrom the controller

FR1

KM1 KM2

FR2

PRFL2 L3

B

C

N

E

com on

95

96

A1

A2

95

96

A1

A2

1 3 5

2 4 6

1 3 5

2 4 6

3~3~

1

2

1

2

1

2 1

2

1

2

1

2

A1

A2

A1

A2

A1

A2

A1

A2

A1

A2

A1

A2

The Controller

N

1 2 3 4 5 6 7 8 9 10 11 PE

N RH RM RL N RM RL

EM1 EM2

1 2 3

12 13 14 15 16 17

4 5 6 7

NRH

1~ 1~

C1 C2

C1 C2

QF Circuit breaker

KA1-6 Intermediate Relay

C1-2 Capacitance

EM1-2 Motor

FU Fuse

Wiring diagrams

Working with Dunnair‘s DAT 770 Thermostat

Page 27: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

27

Counterflow Energy Recovery Ventilator

Wiring diagram for SCM, SCMS, HCV and HCH models

Wiring diagrams

Three phase five line475V 50HZ 3P

AQF

KM1 KM2

Power Supply240V 50HZ 1P

LQF

KA1

KA2KA3

KA4

KA6KA5

EM1 EM2

KA1

NRLRMRHNRLRMRH

32

1

1L

N

3

The Controller

N

1 2 3 4 5 6 7 8 9 10 11 PE

N U1 V1 W1 U2 V2 W2

EM1 EM2

1 2 3

2

1

N N

4 5 6 7

KA2 KA3 KA4 KA5 KA6

FU

N

E

U1 V1 W1 U2 V2W2

EM1 EM2

FR1 FR2

PRF

L1 FU

Signal controlfrom the controller

Signal controlfrom the controller

FR1

KM1 KM2

FR2

PRFL2 L3

B

C

N

E

com on

95

96

A1

A2

95

96

A1

A2

1 3 5

2 4 6

1 3 5

2 4 6

3~3~

1

2

1

2

1

2 1

2

1

2

1

2

A1

A2

A1

A2

A1

A2

A1

A2

A1

A2

A1

A2

The Controller

N

1 2 3 4 5 6 7 8 9 10 11 PE

N RH RM RL N RM RL

EM1 EM2

1 2 3

12 13 14 15 16 17

4 5 6 7

NRH

1~ 1~

C1 C2

C1 C2

Working with Dunnair‘s DAT 770 Thermostat

QF Circuit breaker

KM1-2 Contractor

FU Fuse

PRF Phase Protection

FR1-2 Thermal Relay

EM1-2 Motor

Page 28: Energy Recovery Ventilatordunnair.com.au/au/assets/Uploads/ERV.pdf · 2015. 12. 14. · 3 CounterFlow Energy Recovery Ventilator The newly released CounterFlow Energy Recovery Ventilator

www.dunnair.com.au

Dunnair (Aust) Pty Ltd supports a policy of continuous product improvement. Therefore specification and designs are subject to change without prior notice. Dunnair (Aust) Pty Ltd accepts no responsibility for possible errors in catalogues, brochures and other printed material.

Quality Engineering Solutions

DUNNAIR (Aust) Pty Ltd

Head Office: 140 Bernard Street, Cheltenham VIC 3192 p 03 8586 8200 f 03 8586 8201 e [email protected] w www.dunnair.com.au

Dunnair New South Wales: p 02 9674 1577 f 02 9674 1588 e [email protected]

Dunnair SA & NT: p 08 8240 2888 f 08 8240 2777 e [email protected]

Dunnair Western Australia: p 08 9418 2444 f 08 9418 2100 e [email protected]

New Zealand (agent): p +64 9 582 1012 e [email protected]

Dunnair Victoria: p 03 9558 7001 f 03 9551 1644 e [email protected]

Dunnair Queensland: p 07 3890 8796 f 07 3890 8642 e [email protected]

Dunnair Tasmania: p 0418 756 643 f 03 6425 3531 e [email protected]

New Zealand (agent): p: +64 9 582 1012 e: [email protected]

Hong Kong: p: +852 2575 7080 e: [email protected]

Guangzhou:p: +86 139 0238 2104 e: [email protected]

Contact: Ms Fanny Leung

Contact: Mr Rob Morgan

Contact: Mr Jeff He

Shanghai:p: +86 158 8806 3726 e: [email protected]: Ms Shelly Xiong

Thailand:

P: +66 8 7074 2965

E: [email protected]: Mr Giuseppe Di Martino

Singapore:Add: 240 Macpherson Road,#05-04/05,

Pines Industrial Building Singapore 348574

E: [email protected]

Contact: Mr Derek Wong

DUNNAIR OVERSEAS REPRESENTING OFFICES