GEA-Chiller
Energy efficient, compact, and versatile
Process- and Comfort Air Conditioning | Product Overview
Air Treatment
Outside installation Inside installation
CompressorCondensing unit
Chiller
Split without evaporator
Packaged
GCA GWCGRCGSDC
GLCU
GSAC
Heat pumps
GSAH GLWH
GAH
GLWCGLRCGDC
Chiller
Water cooledAir cooledAir cooled
Packaged for duct connection
GAC / GAH
GLDC
GLAC / GLAH
GDC
GCA
GLCU
GLWC / GLWH
GWC/GRC
GLRC
Air Treatment
GSAC/ GSAH
GSDC/ GSDH
GLAC
GLAH
Heat pumps Heat pumps
GSDH
GLDC
GAC
Split withoutcondenser
Packagedwithout
heat rejection
Ou
tsid
e i
nsta
llati
on
Insid
e i
nsta
llati
on
10 20 40 60 80 100 150 200 300 400 500
Air cooled chiller
Heat pump variant
Air/water
Compressor/
Condensing unit
Air cooled chiller
for duct connection
Heat pump
air/water
Chiller without
condenser
Water cooled chiller
Heat pump
water/water
GAC (N,P,B) 005 … 024 CC1
GCA 100 … 250 AD1/BD4
GSAC 0011 ... 0061 ED1/5
GSAH 0011 ... 0061 ED1/5
GSDH 0011 ... 0061 ED1/5
GSDC 0011 ... 0061 ED1/5
GDC 005 … 010 AC1
GLCU 0524 … 0604 AC2
GLCU 0152 … 0512 AC1
GLDC 0152 … 0612 BD2
GLDC 0604 … 1204 BD2
GRC 005 … 024 DC1
GLRC 0152 … 0612 BC2
GLRC 0524 … 0604 BC2
GWC 005 … 024 DC1
GLWC 0152 … 0612 BD2
GLWC 0604 … 1204 BD
GLWC 0401 … 1902 BA2
GLWH 0152 … 0612 BD2
GLWH 0401 … 1902 BA2
GLWH 1001 … 9604 BA2
GLWH 0604 … 1
GLWC 1001 … 9604 BA2
GAH (N,P,B) 005 … 024 CC1
GLAC 0152 … 0612 BD1
GLAH 0152 … 0612 BD1
GLAC 0524 … 1204 BD2
GLAH 0524 … 1204 BD2
GLAC 0751 … 1301 BA2
GLAC 1532 … 2632 BA2
GLAC 1542 … 2642 BA2
GLAC 1502 … 8404 BA2
available in July 2008
Cooling/heating capacity (kW)
750 1000 2000 R-410A R-407C R-134a Screw Scroll Standard Optional Optional compressor compressor hydraulic module hydraulic module pump module
• • •• • • •
• • •• • •
• • •• • •• •• •
• • •• • • •
• • •• • •• •
• •• •
• • •• • •
• • •• • •• • •
• • •• •• •• • •
• • •• • •
• •• •
• • •• • •
• •• •
D2
204 BD2
available in July 2008
GEA Chillers, Heat Pumps, Compressor/Condensing Units Table of Contents
Outside installation
Chiller – air cooled – packaged
1 scroll compressor 4,9 ... 15,4 kW GSAC 0011 ... 0061 ED1/5 6
1…2 scroll compressors 11 … 55 kW GAC_ 005 … 024 CC1 optimized for space saving 7
2 scroll compressors 36 … 159 kW GLAC 0152 … 0612 BD1 8
4 scroll compressors 136 … 325 kW GLAC 0524 … 1204 BD2 9
1 screw compressor 145 … 266 kW GLAC 0751 … 1301 BA2 10
2 screw compressors 277 … 516 kW GLAC 1542 … 2642 BA2 11
2 screw compressors 277 … 516 kW GLAC 1532 … 2632 BA2 standard configuration + SL 12
including hydraulic module
2 screw compressors 294 … 598 kW GLAC 1502 … 2702 BA2 13
2 screw compressors 625 … 1157 kW GLAC 2712 … 4822 BA2 14
3 screw compressors 1198 … 1609 kW GLAC 5403 … 7223 BA2 15
4 screw compressors 1744 kW GLAC 8404 BA2 15
Compressor/condensing unit – split – without evaporator
1 scroll compressor 12 … 16 kW GCA 100 … 140 BD4 optimized for space saving 16
1…2 scroll compressors 14 … 28 kW GCA 125 … 250 AD1 Scroll inverter compressor 16
2 scroll compressors 40 … 148 kW GLCU 0152 … 0512 AC1 17
4 scroll compressors 151 … 171 kW GLCU 0524 … 0604 AC2 17
Inside installation
Chiller – air cooled – packaged – for duct connection
1 scroll compressor 4,6 ... 15,4 kW GSDC 0011 ... 0061 ED1/5 18
1 scroll compressor 12 … 24 kW GDC 005 … 010 AC1 optimized for space saving 19
2 scroll compressors 37 … 159 kW GLDC 0152 … 0612 BD2 20
4 scroll compressors 152 … 312 kW GLDC 0604 … 1204 BD2 20
Chiller – air cooled – split – without heat rejection – without condenser
1…2 scroll compressors 12 … 62 kW GRC 005 … 024 DC1 optimized for space saving 21
2 scroll compressors 40 … 168 kW GLRC 0152 … 0612 BC2 22
4 scroll compressors 140 … 162 kW GLRC 0524 … 0604 BC2 22
Chiller – water cooled – packaged – without heat rejection
1…2 scroll compressors 13 … 65 kW GWC 005…024 DC1 optimized for space saving 23
2 scroll compressors 43 … 186 kW GLWC 0152 … 0612 BD2 24
4 scroll compressors 174 … 371 kW GLWC 0604 … 1204 BD2 24
Control cabinet on the lateral side
1 screw compressor 87 … 221 kW GLWC 0401 … 0951 BA2 25
2 screw compressors 178 … 447 kW GLWC 0802 … 1902 BA2 25
Control cabinet on the front side
1 screw compressor 233 … 479 kW GLWC 1001 … 1801 BA2 26
2 screw compressors 460 … 1216 kW GLWC 2002 … 4802 BA2 26
3 screw compressors 1283 … 1403 kW GLWC 5003 … 5403 BA2 27
4 screw compressors 1466 … 2432 kW GLWC 5414 … 9604 BA2 27
Outside installation
Heat pump – air cooled – packaged
1 scroll compressor 5,7 ... 16,8 kW GSAH 0011 ... 0061 ED1/5 28
1…2 scroll compressors 12 … 54 kW GAH_ 005 … 024 CC1 optimized for space saving 29
2 scroll compressors 43 … 173 kW GLAH 0152 … 0612 BD1 30
4 scroll compressors 145 … 356 kW GLAH 0524 … 1204 BD2 31
Inside installation
Heat pump – air cooled – packaged
1 scroll compressor 5,7 ... 16,8 kW GSDH 0011 ... 0061 ED1/5 32
Heat pump – water cooled – packaged – without heat rejection
2 scroll compressors 51 … 215 kW GLWH 0152 … 0612 BD2 33
4 scroll compressors 202 … 428 kW GLWH 0604 … 1204 BD2 33
Control cabinet on the lateral side
1 screw compressor 100 … 252 kW GLWH 0401 … 0951 BA2 34
2 screw compressors 202 … 509 kW GLWH 0802 … 1902 BA2 34
Control cabinet on the front side
1 screw compressor 274 … 547 kW GLWH 1001 … 1801 BA2 35
2 screw compressors 519 … 1374 kW GLWH 2002 … 4802 BA2 35
3 screw compressors 1463 … 1613 kW GLWH 5003 … 5403 BA2 36
4 screw compressors 1647 … 2749 kW GLWH 5414 … 9604 BA2 36
All configurations at a glance 37
Features of our chiller controller of G and GL series 38
Calculation sound power into sound pressure 39
standard configuration + SL
standard configuration + SL
optimized for high efficiency + SL
standard configuration
2 circuit system
standard configuration
standard configuration
standard configuration
standard configuration
standard configuration
standard configuration + LT
standard configuration
standard configuration
standard configuration
6 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
4,9 kW up to 15,4 kWOutside installation
air cooled · packaged GSAC 0011 ... 0041 - ED5
GSAC 0021 ... 0061 - ED1
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
Optimized packaged configuration
with 1 scroll compressor
Cooling operation up to -10 °C outside temperature
Autoadaptive microprocessor control
Integrated chilled water pump
0011
4,9
1,9
17,6
3,11
1
1
1
59
0,8
65
37
900
370
640
80
0021
5,6
2,1
17,6
3,35
1
1
1
57
1,0
66
38
900
370
640
85
0025
6,9
2,5
20,6
3,33
1
1
1
54
1,2
66
38
900
370
940
100
0031
8,6
3,4
24,6
3,28
1
1
1
54
1,5
66
38
900
370
940
105
0041
11,0
4,1
28,6
3,17
1
1
1
43
1,9
69
41
900
370
1240
125
0021
5,6
2,0
7,1
3,37
1
1
1
57
1,0
66
38
900
370
640
85
0025
7,0
2,4
7,6
3,37
1
1
1
54
1,2
66
38
900
370
940
100
0031
8,7
3,1
9,6
3,34
1
1
1
54
1,5
66
38
900
370
940
105
0041
11,4
4,2
11,6
3,30
1
1
1
40
2,0
69
41
900
370
1240
125
0051
13,2
4,7
13,4
3,25
1
1
1
33
2,3
69
41
900
370
1240
145
0061
15,4
5,2
16,9
3,51
1
1
1
30
2,7
69
41
900
420
1390
155
GSAC
kW
kW
A
Quantity
Quantity
Quantity
kPa
m³/h
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Pump
Pump head piping
Nominal volume flow
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
1 ~ 230 Volt (Series ED5) 3 ~ 400 Volt (Series ED1)Supply voltage
PR-2008-0322-GB · Subject to modifications · Status 04/2008 7
Chiller
11 kW up to 55 kWOutside installation
air cooled · packaged GACN 005 … 024 - CC1
GACP 005 … 024 - CC1
GACB 005 … 024 - CC1
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
Space saving optimized configuration
with 1...2 scroll compressors
Cooling operation up to -15 °C outside temperature
Microprocessor control
Controller type: μ-Chiller
Connection to BMS via optional interface
With loose water filter and mounted flow switch
005
11,3
4,5
11
2,93
1
1
1
67
39
1290
734
1230
152
171
239
008
17,9
7,4
17
2,87
1
1
1
76
48
1290
734
1230
218
232
300
010
22,5
8,8
20
3,07
1
1
1
78
50
1290
734
1450
248
262
330
012
26,5
11,5
27
2,74
1
1
1
78
50
1290
734
1450
251
265
355
016
37,0
15,2
34
3,07
2
2
2
79
51
2580
734
1321
436
457
525
020
46,6
18,1
40
3,30
2
2
2
81
53
2580
734
1541
496
518
586
024
55,3
24,0
54
2,94
2
2
2
81
53
2580
734
1541
503
524
592
without pump – without buffer tank
with pump
with pump – with buffer tank
without pump – without buffer tank
with pump
with pump - with buffer tank
GACN
GACP
GACB
GAC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
GACN
kg
GACP
kg
GACB
kg
refrigerant R-407C
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
Operating weight
Operating weight
8 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
36 kW up to 159 kWOutside installation
air cooled · packagedGLAC 0152 … 0612 - BD1
GLAC 0152 … 0612 - BD1.SL
Standard configuration with 2 scroll compressors
Buffer tank and pump as option
(GLHM hydraulic module))
Cooling operation up to -15 °C outside temperature
Autoadaptive microprocessor control
Controller type: W3000 „B-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
Mounted with water filter
as above, however with noise optimized model – SL
0152
36,1
15,1
35
4,03
2
1
2
79
51
1695
1120
1420
370
0182
42,8
16,5
39
4,20
2
1
2
79
51
1695
1120
1420
410
0202
50,7
18,9
47
4,25
2
1
2
80
52
2195
1120
1420
460
0252
57,6
21,2
54
4,22
2
1
2
80
52
2195
1120
1420
490
0302
74,2
28,6
65
4,11
2
1
2
81
53
2745
1120
1420
660
0352
84,4
33,7
75
3,99
2
1
2
83
55
2745
1120
1420
720
0412
96,4
37,1
83
4,02
2
1
2
83
55
2745
1120
1420
790
0452
108,8
41,4
93
4,15
2
1
2
83
55
2745
1120
1420
820
0512
122,0
45,9
103
4,06
2
1
2
84
56
3245
1120
1420
930
0552
144,0
50,2
116
4,40
2
1
2
87
59
3245
1120
1620
950
0612
158,6
58,6
129
4,20
2
1
2
87
59
3245
1120
1620
960
0152
33,8
16,3
35
3,77
2
1
2
76
48
1695
1120
1420
390
0182
42,3
17,0
39
3,93
2
1
2
77
49
2195
1120
1420
450
0202
47,8
20,3
47
4,01
2
1
2
77
49
2195
1120
1420
480
0252
55,5
22,6
54
3,89
2
1
2
78
50
2745
1120
1420
540
0302
69,9
30,9
65
3,86
2
1
2
78
50
2745
1120
1420
700
0352
85,4
33,6
75
3,87
2
1
2
81
53
3245
1120
1620
780
0412
96,8
37,3
83
3,91
2
1
2
81
53
3245
1120
1620
860
0452
106,1
43,2
93
3,91
2
1
2
81
53
3245
1120
1620
910
0512
117,5
48,1
103
3,90
2
1
2
82
54
3245
1120
1620
940
0552
138,8
53,1
116
4,19
2
1
2
84
56
3245
1120
1620
950
0612
150,9
62,4
129
3,96
2
1
2
84
56
3245
1120
1620
960
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLAC
kW
kW
A
Anzahl
Anzahl
Anzahl
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAC-SL
kW
kW
A
Anzahl
Anzahl
Anzahl
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
PR-2008-0322-GB · Subject to modifications · Status 04/2008 9
Chiller
136 kW up to 325 kWOutside installation
air cooled · packaged GLAC 0524 … 1204 - BD2
GLAC 0524 … 1204 - BD2.SL
Standard configuration with 4 scroll compressors
Buffer tank and pump as option
(GLHM hydraulic module)
Cooling operation up to -15 °C outside temperature
Autoadaptive microprocessor control
Controller type: W3000 „L-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
Mounted with water filter
as above, however with noise optimized model – SL
0524
136
53,8
116
3,60
4
2
4
92
64
3110
2220
1700
1450
0604
154
59,8
127
3,79
4
2
4
92
64
3110
2220
1700
1620
0704
177
67,7
143
3,91
4
2
4
92
64
3110
2220
2150
1780
0804
200
74,9
167
4,08
4
2
4
92
64
3110
2220
2150
1890
0904
223
84,4
187
4,15
4
2
4
93
65
4110
2220
2150
2070
1004
255
94,2
206
3,96
4
2
4
94
66
4110
2220
2150
2220
1104
293
106,3
232
4,10
4
2
4
95
67
4110
2220
2150
2380
1204
325
121,2
266
4,16
4
2
4
95
67
4110
2220
2150
2530
0524
130
51,9
116
4,14
4
2
4
82
54
3110
2220
2150
1570
0604
147
58,9
127
4,14
4
2
4
82
54
3110
2220
2150
1770
0704
161
70,8
143
4,13
4
2
4
82
54
3110
2220
2150
1860
0804
193
75,3
167
4,08
4
2
4
83
55
4110
2220
2150
2120
0904
211
87,2
187
4,08
4
2
4
83
55
4110
2220
2150
2180
1004
235
96,4
206
4,10
4
2
4
83
55
4110
2220
2150
2320
1104
278
106,2
232
4,39
4
2
4
85
57
5110
2220
2150
2630
1204
313
121,2
266
4,19
4
2
4
86
58
5110
2220
2150
2770
GLAC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAC-SL
kW
kW
A
Anzahl
Anzahl
Anzahl
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
10 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
145 kW up to 266 kWOutside installation
air cooled · packaged GLAC 0751 … 1301 - BA2
GLAC 0751 … 1301 - BA2.SL
Standard configuration with 1 screw compressor
Buffer tank and pump as option
(GLHM hydraulic module)
Cooling operation up to -15 °C outside temperature
Autoadaptive microprocessor control
Controller typep: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
With loose water filter
as above, however with noise optimized model – SL
0751
145
52
117
3,50
1
1
3
94
66
3110
2222
2150
1680
0851
163
61
127
3,42
1
1
3
94
66
3110
2222
2150
1710
0951
182
69
144
3,52
1
1
3
94
66
3110
2222
2150
1780
0961
201
75
144
3,63
1
1
3
94
66
3110
2222
2150
1860
1021
234
85
154
3,49
1
1
3
96
68
4610
2222
2150
2590
1301
266
93
201
3,54
1
1
3
96
68
4610
2222
2150
2720
0751
134
53
117
3,54
1
1
3
84
56
3110
2222
2150
1680
0851
151
63
127
3,41
1
1
3
84
56
3110
2222
2150
1770
0951
166
74
144
3,40
1
1
3
84
56
3110
2222
2150
1840
0961
197
76
144
3,69
1
1
3
84
56
3110
2222
2150
1980
1021
223
90
154
3,58
1
1
3
86
58
4610
2222
2150
2670
1301
238
101
201
3,32
1
1
3
86
58
4610
2222
2150
2720
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLAC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAC-SL
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
PR-2008-0322-GB · Subject to modifications · Status 04/2008 11
Chiller
277 kW up to 516 kWOutside installation
air cooled · packaged GLAC 1542 … 2642 - BA2
GLAC 1542 … 2642 - BA2.SL
Standard configuration with 2 screw compressors
Cooling operation up to -15 °C outside temperature
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with noise optimized model – SL
1542
277
104
227
3,64
2
2
6
97
69
4610
2222
2150
3490
1742
329
121
253
3,57
2
2
6
97
69
4610
2222
2420
3680
1942
366
139
287
3,56
2
2
6
97
69
4610
2222
2420
3810
1962
398
154
287
3,58
2
2
6
97
69
4610
2222
2420
4100
2442
466
179
360
3,61
2
2
6
99
71
5610
2222
2430
5140
2642
516
193
398
3,49
2
2
6
99
71
5610
2222
2430
5340
1542
252
112
221
3,50
2
2
6
86
58
4610
2222
2150
3580
1742
296
128
253
3,47
2
2
6
87
59
4610
2222
2420
3790
1942
334
149
294
3,46
2
2
6
87
59
5610
2222
2430
3960
1962
377
164
294
3,62
2
2
6
87
59
5610
2222
2430
4410
2442
443
183
368
3,69
2
2
6
89
61
6610
2222
2430
5730
2642
484
199
406
3,52
2
2
6
89
61
6610
2222
2430
5970
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLAC-SL
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
12 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
277 kW up to 516 kWOutside installation
air cooled · packaged GLAC 1532 … 2632 - BA2
GLAC 1532 … 2632 - BA2.SL
Standard configuration with 2 screw compressors
Standard hydraulic module GLHM with integrated
buffer tank and pump
High pump heads are available
Following pump heads for remaining piping by others
Cooling operation up to -15 °C outside temperature
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
With loose water filter
1532
277
107
239
3,64
2
2
6
M
124
48
97
69
4610
2222
2150
4197
1000
1732
329
124
265
3,57
2
2
6
M
96
57
97
69
4610
2222
2420
4387
1000
1932
366
143
303
3,56
2
2
6
N
126
63
97
69
4610
2222
2420
4507
1000
1952
398
158
303
3,56
2
2
6
N
111
69
97
69
4610
2222
2420
4527
1000
2432
466
185
382
3,61
2
2
6
O
96
80
99
71
5610
2222
2430
6184
1500
2632
516
201
428
3,49
2
2
6
P
132
89
99
71
5610
2222
2430
6404
1500
1532
252
116
236
3,50
2
2
6
Q
117
48
86
58
4610
2222
2150
4353
1000
1732
296
134
270
3,47
2
2
6
R
125
57
87
59
4610
2222
2420
4569
1000
1932
334
155
313
3,46
2
2
6
R
110
63
87
59
4610
2222
2420
4733
1000
1952
377
172
318
3,62
2
2
6
S
149
69
87
59
4610
2222
2420
4918
1000
2432
443
201
395
3,69
2
2
6
S
118
80
89
61
5610
2222
2430
6818
1500
2632
484
207
437
3,52
2
2
6
S
98
89
89
61
5610
2222
2430
7074
1500
as above, however with noise optimized model – SL
GLAC
kW
kW
A
Quantity
Quantity
Quantity
Typ
kPa
m³/h
dB(A)
dB(A)
mm
mm
mm
kg
ltr.
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
1 Standard pump
Pump head piping
Nominal volume flow
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
incl. buffer tank with
GLAC
kW
kW
A
Quantity
Quantity
Quantity
Typ
kPa
m³/h
dB(A)
dB(A)
mm
mm
mm
kg
ltr.
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
1 Standard pump
Pump head piping
Nominal volume flow
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
incl. buffer tank with
PR-2008-0322-GB · Subject to modifications · Status 04/2008 13
Chiller
294 kW up to 598 kWOutside installation
air cooled · packaged GLAC 1502 …2702 - BA2
GLAC 1502 …2702 - BA2.SL
High efficient optimized configuration
with 2 screw compressors
Cooling operation up to -15 °C outside temperature
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with noise optimized model – SL
1502
294
101
227
3,86
2
2
6
98
70
4000
2260
2430
3730
1702
328
120
253
3,75
2
2
6
98
70
4000
2260
2430
3760
1902
364
134
292
3,74
2
2
6
99
71
4000
2260
2430
3850
1922
414
147
292
3,85
2
2
6
99
71
4900
2260
2430
4740
1972
439
157
292
3,84
2
2
6
99
71
4900
2260
2430
5300
2022
480
160
303
3,88
2
2
6
99
71
4900
2260
2430
5810
2602
529
185
396
3,76
2
2
6
99
71
4900
2260
2430
5810
2652
562
195
421
3,88
2
2
6
99
71
4900
2260
2430
5910
2702
598
208
445
3,98
2
2
6
99
71
4900
2260
2430
6030
1502
275
105
227
3,85
2
2
6
85
57
4000
2260
2430
3810
1702
300
127
253
3,58
2
2
6
85
57
4000
2260
2430
3840
1902
337
140
292
3,70
2
2
6
86
58
4000
2260
2430
3930
1922
389
159
292
3,83
2
2
6
86
58
4900
2260
2430
4870
1972
413
171
292
3,78
2
2
6
86
58
4900
2260
2430
5430
2022
454
174
303
3,87
2
2
6
87
59
4900
2260
2430
5970
2602
486
197
396
3,60
2
2
6
87
59
4900
2260
2430
5970
2652
520
208
421
3,75
2
2
6
87
59
4900
2260
2430
6070
2702
554
223
445
3,82
2
2
6
87
59
4900
2260
2430
6180
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLAC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAC-SL
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
14 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
625 kW up to 1157 kWOutside installation
air cooled · packaged GLAC 2712 … 4822 - BA2
GLAC 2712 … 4822 - BA2.SL
High efficient optimized configuration
with 2 screw compressors
Cooling operation up to -15 °C outside temperature
Autoadaptive microprocessor control
Controller type:: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with noise optimized model – SL
2712
625
217
451
3,89
2
2
6
101
73
5800
2260
2430
6190
2722
681
222
451
4,07
2
2
6
101
73
5800
2260
2430
6520
3152
730
260
515
3,94
2
2
6
101
73
5800
2260
2430
7190
3602
785
289
579
3,94
2
2
6
101
73
5800
2260
2430
7810
3902
831
302
623
3,78
2
2
6
102
74
7000
2260
2430
8220
4202
900
321
661
3,79
2
2
6
102
74
7000
2260
2430
8750
4212
968
352
678
3,78
2
2
6
103
75
9400
2260
2430
9680
4222
1033
382
678
3,90
2
2
6
103
75
9400
2260
2430
9950
4822
1157
384
760
4,14
2
2
6
104
76
9400
2260
2430
10360
2712
586
234
451
3,84
2
2
6
88
60
5800
2260
2430
6350
2722
638
247
451
3,96
2
2
6
88
60
5800
2260
2430
6680
3152
669
290
515
3,70
2
2
6
88
60
5800
2260
2430
7230
3602
726
312
579
3,73
2
2
6
88
60
5800
2260
2430
7760
3902
768
323
623
3,61
2
2
6
89
61
7000
2260
2430
8400
4202
822
346
661
3,56
2
2
6
89
61
7000
2260
2430
8930
4212
903
383
678
3,73
2
2
6
90
62
9400
2260
2430
8990
4222
963
439
678
3,81
2
2
6
90
62
9400
2260
2430
10150
4822
1088
426
760
4,08
2
2
6
91
63
9400
2260
2430
10570
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLAC-SL
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
PR-2008-0322-GB · Subject to modifications · Status 04/2008 15
Chiller
1198 kW up to 1744 kWOutside installation
air cooled · packaged GLAC 5403 … 8404 - BA2
GLAC 5403 … 8404 - BA2.SL
High efficient optimized configuration
with 3...4 screw compressors
Cooling operation up to -15 °C outside temperature
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with noise optimized model – SL
5403
1198
431
874
3,98
3
3
6
105
77
10300
2260
2430
12080
5423
1317
486
874
3,84
3
3
6
105
77
10300
2260
2430
12260
5703
1238
450
912
4,09
3
3
6
105
77
10300
2260
2430
12190
6903
1433
520
1103
3,68
3
3
6
105
77
11200
2260
2430
12680
7203
1486
536
1144
3,82
3
3
6
105
77
11200
2260
2430
12820
7223
1609
593
1144
3,79
3
3
6
105
77
11200
2260
2430
12950
8404
1744
643
1331
3,66
4
4
8
105
77
11200
2260
2430
16740
5403
1092
471
874
3,72
3
3
6
92
64
10300
2260
2430
12110
5423
1230
551
874
3,66
3
3
6
92
64
10300
2260
2430
12290
5703
1142
483
912
3,92
3
3
6
92
64
10300
2260
2430
12220
6903
1308
557
1103
3,61
3
3
6
92
64
11200
2260
2430
12990
7203
1359
577
1144
3,60
3
3
6
92
64
11200
2260
2430
13130
7223
1512
653
1144
3,90
3
3
6
92
64
11200
2260
2430
13270
8404
1590
682
1331
3,51
4
4
8
92
64
11200
2260
2430
16660
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLAC-SL
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
16 PR-2008-0322-GB · Subject to modifications · Status 04/2008
12 kW up to 28 kWOutside installation
air cooled · split · without evaporator GCA 100 … 140 - BD4
GCA 125 … 250 - AD1
Space saving optimized configuration
with 1...2 scroll compressors
Inverter scroll compressor
Cooling operation up to -5 °C outside temperature
Controls by others
Necessary accessories:
Expansion valve kit GZCA...AD.R122
Communication box GZCAGFCAD.E13
100-BD4
11,8
3,5
27
-
1
1
24…100 %
66
38
900
320
1345
125
1 ~ 230 Volt
125-BD4
14,2
4,3
27
-
1
1
24…100 %
67
39
900
320
1345
125
140-BD4
15,8
5,0
27
-
1
1
24…100 %
69
41
900
320
1345
125
125-AD1
14,0
3,5
16
-
1
1
50…100 %
72
44
635
765
1680
157
3 ~ 400 Volt
200-AD1
22,4
5,6
17
-
1
1
50…100 %
78
50
930
765
1680
185
250-AD1
28,0
7,4
32
-
2
1
50…100 %
78
50
930
765
1680
238
Compressor/Condensing unit
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with evaporation temperature 7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
063
6,4
7,8
0,96
1,22
100
125
401
215
78
2,9
080
8,1
9,9
1,22
1,53
100
140
401
215
78
2,9
100
10,1
12,3
1,53
1,91
100
200
401
215
78
2,9
125
12,6
15,4
1,91
2,14
100
250
401
215
78
2,9
140
14,4
17,6
2,14
2,97
125
250
401
215
78
2,9
200
20,2
24,6
3,06
3,8
200
250
401
215
78
2,9
250
25,2
30,8
3,82
4,78
200
250
401
215
78
2,9
GZCA ### AD.R12
kW
kW
dm³
dm³
mm
mm
mm
kg
Cooling capacity
min.
max.
Evaporator volume
min.
max.
can be combined with:
from capacity size
to capacity size
Length
Width
Height
Operating weight
GCA
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
Accessories: overview expansion valves
Supply voltage
PR-2008-0322-GB · Subject to modifications · Status 04/2008 17
Compressor/Condensing unit
40 kW up to 171 kWOutside installation
air cooled · split · without evaporator GLCU 0152 … 0512 - AC1
GLCU 0524 … 0604 - AC2
Standard configuration with 2...4 scroll compressors
System with 2 circuits
Cooling operation up to -15 °C outside temperature
Controls by others
Recommended accessories:
Refrigeration accessories GLZCU R06
(Expansion valve, solenoid valve, filter drier and sight window,
each refrigeration circuit for installation by others)
0152
40,3
14,8
31
-
2
2
2
78
50
1695
1120
1420
540
0182
50,4
18,2
41
-
2
2
2
79
51
2195
1120
1420
590
0202
58,5
20,7
47
-
2
2
2
79
51
2195
1120
1420
620
0252
71,1
25,9
60
-
2
2
2
81
53
2745
1120
1420
680
0302
85,2
30,2
65
-
2
2
2
81
53
2745
1120
1420
730
0412
120,2
40,4
88
-
2
2
2
85
57
3245
1120
1620
990
0512
148,0
48,9
105
-
2
2
2
85
57
3245
1120
1620
1050
0524
150,8
56,0
115
-
4
2
4
94
66
3110
2220
1700
1620
0604
171,1
66,0
129
-
4
2
4
94
66
3110
2220
1700
1700
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with evaporation temperature 7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLCU
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R407C
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
18 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
4,9 kW up to 15,4 kWInside installation
air cooled · packaged · duct connection GSDC 0011 ... 0041 - ED5
GSDC 0021 ... 0061 - ED1
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
Space saving optimized configuration
with 1 scroll compressor
Cooling operation up to -10 °C outside temperature
Autoadaptive microprocessor control
Connection to BMS via optional interface
0011
4,9
200
2,5
20,3
2,24
1
1
1
59
0,8
68
40
900
580
640
110
0021
5,6
100
2,6
20,3
2,48
1
1
1
57
1,0
68
40
900
580
640
115
0025
6,9
200
3,1
23,3
2,68
1
1
1
54
1,2
68
40
900
580
940
130
0031
8,6
80
4,0
27,3
2,60
1
1
1
54
1,5
68
40
900
580
940
135
0041
11,0
80
5,2
31,3
2,39
1
1
1
43
1,9
71
43
900
580
1240
180
0021
5,6
100
2,6
9,8
2,54
1
1
1
57
1,0
68
40
900
580
640
115
0025
7,0
200
3,0
10,3
2,76
1
1
1
54
1,2
68
40
900
580
940
130
0031
8,7
80
3,7
12,3
2,70
1
1
1
54
1,5
68
40
900
580
940
135
0041
11,4
80
5,3
14,3
2,48
1
1
1
40
2,0
71
43
900
580
1240
180
0051
13,2
80
5,8
16,1
2,53
1
1
1
33
2,3
71
43
900
580
1240
200
0061
15,4
70
6,4
19,3
2,78
1
1
1
30
2,7
71
43
900
630
1390
210
GSDC
kW
Pa
kW
A
Quantity
Quantity
Quantity
kPa
m³/h
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Max. external pressure
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Pump
Pump head piping
Nominal volume flow
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
1 ~ 230 Volt (Series ED5) 3 ~ 400 Volt (Series ED1)Supply voltage
PR-2008-0322-GB · Subject to modifications · Status 04/2008 19
Chiller
12 kW up to 24 kWInside installation
air cooled · packaged · duct connection
GDC 005 … 010 - AC1
Space saving optimized configuration
with 1 scroll compressorr
Cooling operation up to -10 °C outside temperature
Microprocessor control
Controller type: μ-chiller
Connection to BMS via optional interface
005
11,6
100
5,3
17
2,74
1
1
1
63
35
856
630
1345
166
008
18,4
150
7,8
21
2,81
1
1
1
66
38
1180
630
1290
228
010
23,8
150
9,9
26
2,52
1
1
1
67
39
1330
630
1395
266
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with evaporation temperature 7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GDC
kW
Pa
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-407C
Nominal cooling capacity
Max. external pressure
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
20 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
37 kW up to 312 kWInside installation
air cooled · packaged · duct connection GLDC 0152 … 0612 - BD2
GLDC 0604 … 1204 - BD2
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
Space saving optimized configuration with 2 scroll compressors
Cooling operation up to -10 °C outside temperature
Autoadaptive microprocessor control
Controller type: W3000 „B-version“ (0152-0612)
W3000 „L-version“ (0604-1204)
Master/slave operation with units
of W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 4 scroll compressors
0152
37,1
480
15,7
38
4,61
2
1
2
85
57
2200
920
1642
680
0182
43,0
380
18,3
40
4,30
2
1
2
88
60
2200
920
1642
680
0202
50,5
370
20,6
48
4,46
2
1
2
88
60
2200
920
1642
710
0252
57,0
370
23,2
52
4,35
2
1
2
88
60
2200
920
1642
730
0302
74,8
230
30,4
66
4,18
2
1
2
90
62
2200
920
1642
890
0352
86,4
420
36,8
81
3,86
2
1
2
95
67
2602
1104
1927
1130
0412
97,9
410
40,7
89
3,88
2
1
2
95
67
2602
1104
1927
1180
0452
108,8
310
46,8
99
3,73
2
1
2
96
68
2602
1104
1927
1220
0512
120,9
300
51,5
108
3,74
2
1
2
96
68
2602
1104
1927
1270
0552
137,7
340
58,3
122
4,17
2
1
2
96
68
3602
1104
1927
1460
0612
158,7
310
67,2
143
3,94
2
1
2
98
70
3602
1104
1927
1460
0604
151,6
390
62,5
139
3,86
4
2
4
97
69
3602
1277
1900
1855
0704
171,8
280
73,1
156
3,72
4
2
4
98
70
3602
1277
1900
1950
0804
194,8
320
83,5
181
3,61
4
2
4
99
71
4602
1277
2235
2320
0904
221,7
400
89,6
201
3,97
4
2
4
98
70
4602
1277
2235
2455
1004
243,9
310
101,6
220
3,77
4
2
4
99
71
4602
1277
2235
2525
1104
281,3
270
115,0
246
3,88
4
2
4
99
71
4602
1277
2235
2705
1204
312,2
300
133,2
282
3,74
4
2
4
100
72
5602
1277
2235
2895
GLDC
kW
Pa
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Max. external pressure
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLDC
kW
Pa
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Max. external pressure
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
PR-2008-0322-GB · Subject to modifications · Status 04/2008 21
Chiller
12 kW up to 62 kWInside installation
air cooled · split · without condenser
GRC 005 … 024 - DC1
Space saving optimized configuration
with 1... 2 scroll compressors
On site condenser by others, air or water cooled
Autoadaptive microprocessor control
Controller type: μ-chiller
Connection to BMS via optional interface
With loose water filter and flow switch
005
12,1
4,2
8
-
1
1
1
64
36
600
600
600
104
008
20,0
6,7
14
-
1
1
1
64
36
600
600
600
138
010
26,8
8,7
18
-
1
1
1
64
36
600
600
600
144
012
31,2
10,2
20
-
1
1
1
71
43
600
600
600
149
016
40,0
13,5
28
-
2
2
2
67
39
1200
600
600
252
020
53,7
18,0
36
-
2
2
2
67
39
1200
600
600
265
024
62,4
20,5
40
-
2
2
2
74
46
1200
600
600
274
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and air intake temperature 45 °C, subcooling 5KSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GRC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-407C
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
22 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
40 kW up to 162 kWInside installation
air cooled · split · without condenser GLRC 0152 … 0612 - BC2
GLRC 0524 … 0604 - BC2
Standard configuration with 2...4 scroll compressors
On site condenser by others, air or water cooled
Autoadaptive microprocessor control
Controller type: W3000 „B-version“ (0152-0612)
W3000 „L-version“ (0524-0604)
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
0152
39,8
10,8
29
-
2
2
2
72
44
800
600
940
305
0182
47,8
12,7
37
-
2
2
2
72
44
800
600
940
310
0202
55,3
14,5
42
-
2
2
2
72
44
800
600
940
320
0252
69,0
18,1
54
-
2
2
2
72
44
800
600
940
335
0302
85,5
25,9
57
-
2
2
2
73
45
1112
755
1485
485
0412
111,8
32,4
75
-
2
2
2
74
46
1112
755
1485
580
0512
137,7
40,2
93
-
2
2
2
75
47
1112
755
1485
630
0612
167,6
50,5
117
-
2
2
2
76
48
1112
755
1485
690
0524
140,1
41,8
100
-
4
2
4
75
47
2040
755
1485
880
0604
161,5
48,8
114
-
4
2
4
75
47
2040
755
1485
925
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and condensing temperature 45 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLRC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-407C
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
PR-2008-0322-GB · Subject to modifications · Status 04/2008 23
Chiller
13 kW up to 65 kWInside installation
water cooled · packaged · without heat rejection
GWC 005 … 024 - DC1
Space saving optimized configuration
with 1...2 scroll compressors
Microprocessor control
Controller type: μ-chiller
Connection to BMS via optional interface
With loose water filter and flow switch
005
13,0
3,7
8
-
1
1
1
64
36
600
600
600
113
008
21,5
6,0
14
-
1
1
1
64
36
600
600
600
150
010
28,0
7,8
18
-
1
1
1
64
36
600
600
600
160
012
32,5
9,1
20
-
1
1
1
71
43
600
600
600
167
016
43,0
12,1
28
-
2
2
2
67
39
1200
600
600
300
020
56,0
16,0
36
-
2
2
2
67
39
1200
600
600
320
024
65,0
18,3
40
-
2
2
2
74
46
1200
600
600
334
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and cool water 30/35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-407C
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
24 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
43 kW up to 371 kWInside installation
water cooled · packaged · without heat rejection GLWC 0152 … 0612 - BD2
GLWC 0604 … 1204 - BD2
Standard configuration with 2 scroll compressors
Autoadaptive microprocessor control
Controller type: W3000 „B-version“ (0152-0612)
W3000 „L-version“ (0604-1204)
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 4 scroll compressors
0152
43,4
10,0
31
5,81
2
1
2
73
45
1055
649
1255
280
0182
50,1
11,3
33
5,98
2
1
2
74
46
1055
649
1255
295
0202
58,9
13,0
41
6,01
2
1
2
74
46
1055
649
1255
300
0252
66,4
15,2
45
5,69
2
1
2
74
46
1055
649
1255
310
0262
72,6
16,6
51
5,59
2
1
2
75
47
1055
649
1255
315
0302
86,7
19,5
56
5,66
2
1
2
76
48
1222
873
1496
565
0352
101,2
22,7
64
5,80
2
1
2
77
49
1222
873
1496
605
0412
114,7
25,9
72
5,71
2
1
2
77
49
1222
873
1496
635
0452
128,6
28,9
82
5,80
2
1
2
78
50
1222
873
1496
675
0512
143,5
32,2
92
5,78
2
1
2
78
50
1222
873
1496
715
0552
164,9
36,9
105
5,93
2
1
2
79
51
1222
873
1496
765
0612
186,3
41,6
118
5,79
2
1
2
79
51
1222
873
1496
795
0604
174
39
112
5,79
4
2
4
86
58
2227
877
1780
1055
0704
203
45
128
5,92
4
2
4
87
59
2227
877
1780
1130
0804
228
52
144
5,82
4
2
4
88
60
2227
877
1780
1190
0904
258
58
164
5,93
4
2
4
89
61
2227
877
1780
1270
1004
288
64
183
5,93
4
2
4
90
62
2227
877
1780
1355
1104
329
74
209
5,99
4
2
4
91
63
2227
877
1780
1450
1204
371
84
236
5,89
4
2
4
91
63
2227
877
1780
1510
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and cool water 30/35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
PR-2008-0322-GB · Subject to modifications · Status 04/2008 25
Chiller
87 kW up to 447 kWInside installation
water cooled · packaged · without heat rejection GLWC 0401 … 0951 - BA2
GLWC 0802 … 1902 - BA2
Standard configuration with 1 screw compressor
Control cabinet on lateral side
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 2 screw compressors
0401
87
20
55
5,15
1
1
3
91
63
2300
1000
1500
800
0501
107
25
67
5,32
1
1
3
92
64
2500
1000
1500
840
0551
130
28
80
5,25
1
1
3
94
66
2500
1000
1500
1160
0651
147
33
92
5,29
1
1
3
94
66
2500
1000
1500
1180
0751
165
37
105
5,40
1
1
3
94
66
2500
1000
1500
1190
0851
198
43
115
5,54
1
1
3
94
66
3200
1000
1500
1270
0951
221
50
132
5,42
1
1
3
94
66
3200
1000
1500
1350
0802
178
39
111
5,39
2
2
6
94
66
3200
1200
1500
1470
1002
217
49
134
5,52
2
2
6
95
67
3200
1200
1500
1490
1102
251
56
161
5,24
2
2
6
97
69
3200
1200
1500
1930
1302
298
66
183
5,49
2
2
6
97
69
3500
1200
1800
2220
1502
340
75
210
5,67
2
2
6
97
69
3500
1200
1800
2260
1702
393
85
230
5,70
2
2
6
97
69
3500
1200
1800
2320
1902
447
100
264
5,61
2
2
6
97
69
3500
1200
1800
2720
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and cool water 30/35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
26 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Chiller
233 kW up to 1216 kWInside installation
water cooled · packaged · without heat rejection GLWC 1001 … 1801 - BA2
GLWC 2002 … 4802 - BA2
Standard configuration with 1 screw compressor
Control cabinet on front side
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 2 screw compressors
1001
233
51
132
5,49
1
1
3
94
66
2800
900
1735
1610
1201
284
60
165
5,87
1
1
3
97
69
3600
900
1750
2070
1301
321
68
184
5,42
1
1
3
97
69
3600
900
1750
2100
1351
362
74
208
5,82
1
1
3
97
69
3600
900
1750
2120
1601
424
89
235
5,71
1
1
3
97
69
3600
900
1950
3160
1801
479
102
272
5,86
1
1
3
97
69
3600
900
1950
3180
2002
460
99
263
5,76
2
2
6
97
69
3600
1120
1900
3050
2402
559
119
329
5,96
2
2
6
99
71
3600
1150
1900
3680
2602
643
137
367
5,59
2
2
6
99
71
4500
1150
1900
4000
2702
733
148
416
6,00
2
2
6
99
71
4500
1150
1900
4040
3202
826
176
470
5,77
2
2
6
99
71
4500
1150
1900
5160
3602
953
204
544
5,98
2
2
6
99
71
4500
1150
2150
5850
4202
1089
233
620
5,56
2
2
6
99
71
4500
1150
2150
6270
4502
1153
242
661
5,82
2
2
6
99
71
4500
1150
2150
6320
4802
1216
251
702
6,06
2
2
6
99
71
4500
1150
2150
6360
GLWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and cool water 30/35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
PR-2008-0322-GB · Subject to modifications · Status 04/2008 27
Chiller
1283 kW up to 2432 kWInside installation
water cooled · packaged · without heat rejection GLWC 5003 … 5403 - BA2
GLWC 5414 … 9604 - BA2
Standard configuration with 3 screw compressors
Control cabinet on front side
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 4 screw compressors
5003
1283
278
742
5,79
3
3
6
101
73
4500
1700
2100
7890
5203
1353
291
779
5,89
3
3
6
101
73
4500
1700
2100
7930
5403
1403
306
816
5,91
3
3
6
101
73
4500
1700
2100
7960
5414
1466
297
832
6,00
4
4
8
102
74
4500
2250
2050
8280
5904
1560
325
886
5,87
4
4
8
102
74
4500
2250
2050
9380
6404
1687
354
940
5,86
4
4
8
102
74
4500
2250
2250
11410
6804
1797
381
1014
5,93
4
4
8
102
74
4500
2250
2250
11460
7204
1906
408
1088
5,98
4
4
8
102
74
4500
2250
2250
11520
7804
2043
436
1164
5,74
4
4
8
102
74
4500
2250
2250
11930
8404
2178
465
1240
5,56
4
4
8
102
74
4500
2250
2250
12350
9004
2306
484
1322
5,82
4
4
8
102
74
4500
2250
2250
12430
9604
2432
503
1404
6,06
4
4
8
102
74
4500
2250
2250
12520
GLWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWC
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and cool water 30/35 °CSound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
28 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Heat pumps
5,7 kW up to 16,8 kWOutside installation
air cooled · packaged GSAH 0011 ... 0041 - ED5
GSAH 0021 ... 0061 - ED1
Space saving optimized configuration
with 1 scroll compressor
Heat pump switch using 4 way valve
Cooling operation up to -10 °C,
Heating operation up to -7 °C outside temperature
Autoadaptive microprocessor control
Integrated chilled water pump
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with warm water 40/45 °C and air intake temperature 7 °C
with chilled water 12/7 °C and air intake temperature 35 °C* in heating mode
Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GSAH
kW
kW
kW
A
Quantity
Quantity
Quantity
kPa
m³/h
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal heating capacity
Nominal cooling capacity
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Pump
Pump head piping
Nominal volume flow
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
1 ~ 230 Volt (Series ED5) 3 ~ 400 Volt (Series ED1)
0011
5,7
4,6
2,3
17,6
2,96
1
1
1
59
0,8
65
37
900
370
640
90
0021
6,4
5,4
2,4
17,6
3,19
1
1
1
57
1,0
66
38
900
370
640
95
0025
8,1
6,6
2,9
20,6
3,16
1
1
1
54
1,2
66
38
900
370
940
110
0031
10,0
8,2
3,6
24,6
3,01
1
1
1
54
1,5
66
38
900
370
940
115
0041
12,4
10,4
4,5
28,6
3,01
1
1
1
43
1,9
69
41
900
370
1240
140
0021
6,4
5,3
2,4
7,1
3,21
1
1
1
57
1,0
66
38
900
370
640
95
0025
8,0
6,7
2,7
7,6
3,41
1
1
1
54
1,2
66
38
900
370
940
110
0031
9,7
8,2
3,2
9,6
3,17
1
1
1
54
1,5
66
38
900
370
940
115
0041
12,8
10,8
4,7
11,6
3,13
1
1
1
40
2,0
69
41
900
370
1240
140
0051
14,4
12,6
5,0
13,4
3,08
1
1
1
33
2,3
69
41
900
370
1240
160
0061
16,8
14,6
5,4
16,6
3,33
1
1
1
30
2,7
69
41
900
420
1390
170
Supply voltage
PR-2008-0322-GB · Subject to modifications · Status 04/2008 29
Heat pumps
12 kW up to 54 kWOutside installation
air cooled · packaged GAHN 005 … 024 - CC1
GAHP 005 … 024 - CC1
GAHB 005 … 024 - CC1
Space saving optimized configuration
with 1...2 scroll compressors
Heat pump switch using 4 way valve
Cooling operation up to -15 °C
Heating operation up to -10 °C outside temperature
Autoadaptive microprocessor control
Controller type: μ-chiller
Connection to BMS via optional interface
With loose water filter and mounted flow switch
without pump – without buffer tank
with pump
with pump - with buffer tank
GAHN
GAHP
GAHB
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with warm water 40/45 °C and air intake temperature 7 °C
with chilled water 12/7 °C and air intake temperature 35 °C* in heating mode
Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GAH_
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
GAHN
kg
GAHP
kg
GAHB
kg
refrigerant R-407C
Nominal heating capacity
Nominal cooling capacity
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
Operating weight
Operating weight
without pump – without buffer tank
with pump
with pump – with buffer tank
005
11,9
9,1
4,6
11
-
1
1
1
67
39
1290
734
1230
165
184
252
008
18,5
17,1
7,1
17
-
1
1
1
76
48
1290
734
1230
230
244
312
010
24,0
21,0
9,1
20
-
1
1
1
78
50
1290
734
1450
261
275
343
012
27,0
25,0
10,8
27
-
1
1
1
78
50
1290
734
1450
261
275
343
016
37,0
34,2
14,2
34
-
2
2
2
79
51
2580
734
1321
461
482
550
020
46,0
40,0
17,4
40
-
2
2
2
81
53
2580
734
1541
522
544
612
024
54,0
50,0
21,6
54
-
2
2
2
81
53
2580
734
1541
522
544
612
30 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Heat pumps
43 kW up to 173 kWOutside installation
air cooled · packaged GLAH 0152 … 0612 - BD1
GLAH 0152 … 0512 - BD1.LT
Standard configuration with 2 scroll compressors
Heat pump switch using 4 way valve
Buffer tank and pump as option
(GLHM hydraulic module)
Cooling operation up to -15 °C,
Heating operation up to -5 °C outside temperature
Heating operation up to -10 °C outside temperature with LT model
Autoadaptive microprocessor control
Controller type: W3000 „B-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
With mounted water filter
0152
43
38
14
35
4,04
2
1
2
84
56
1695
1120
1420
450
0182
48
43
16
37
4,08
2
1
2
84
56
1695
1120
1420
460
0202
54
48
18
45
4,03
2
1
2
84
56
1695
1120
1420
470
0252
65
58
21
52
4,00
2
1
2
84
56
2195
1120
1420
560
0302
81
73
26
62
3,95
2
1
2
85
57
2195
1120
1420
690
0352
93
83
30
71
4,06
2
1
2
86
58
2195
1120
1420
750
0412
105
94
34
81
3,92
2
1
2
86
58
2745
1120
1420
840
0452
121
107
38
91
4,09
2
1
2
86
58
2745
1120
1420
910
0512
136
120
42
103
4,04
2
1
2
87
59
3245
1120
1620
1030
0552
157
138
48
116
4,18
2
1
2
87
59
3245
1120
1620
1090
0612
173
151
54
129
3,99
2
1
2
87
59
3245
1120
1620
1100
0152
42
36
14
33
4,09
2
1
2
79
51
1695
1120
1420
450
0182
48
42
15
36
4,16
2
1
2
79
51
1695
1120
1420
480
0202
54
48
18
45
4,03
2
1
2
80
52
2195
1120
1420
520
0252
64
55
21
49
4,02
2
1
2
80
52
2195
1120
1420
560
0302
84
73
26
61
4,08
2
1
2
81
53
2795
1120
1420
770
0352
96
84
30
73
3,96
2
1
2
83
55
2795
1120
1620
840
0412
109
94
34
81
3,94
2
1
2
83
55
2745
1120
1620
910
0452
121
103
38
91
3,93
2
1
2
83
55
2745
1120
1620
950
0512
137
119
42
103
3,99
2
1
2
84
56
3245
1120
1620
1070
as above, however temperature / noise optimized
Cooling operation up to -15 °C, Heating operation up to -10 °C outside temperature with LT model
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with warm water 40/45 °C and air intake temperature 7 °C
with chilled water 12/7 °C and air intake temperature 35 °C* in heating mode
Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLAH
kW
kW
kW
A
Anzahl
Anzahl
Anzahl
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal heating capacity
Nominal cooling capacity
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAH-LT
kW
kW
kW
A
Anzahl
Anzahl
Anzahl
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal heating capacity
Nominal cooling capacity
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
PR-2008-0322-GB · Subject to modifications · Status 04/2008 31
Heat pumps
145 kW up to 356 kWOutside installation
air cooled · packaged GLAH 0524 … 1204 - BD2
GLAH 0524 … 1204 - BD2.LT
Standard configuration with 4 scroll compressors
Heat pump switch using 4 way valve
Buffer tank and pump as option
(GLHM hydraulic module)
Cooling operation up to -15 °C
Heating operation up to -5 °C outside temperature
Heating operation up to -10 °C outside temperature with LT model
Autoadaptive microprocessor control
Controller type: W3000 „L-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
With mounted water filter
0524
145
129
53
116
3,39
4
2
4
92
64
3110
2220
1700
1570
0604
167
147
58
127
3,57
4
2
4
92
64
3110
2220
1700
1750
0704
185
166
65
143
3,64
4
2
4
92
64
3110
2220
2150
1900
0804
209
189
72
167
3,80
4
2
4
92
64
3110
2220
2150
2080
0904
234
211
80
187
3,88
4
2
4
93
65
4110
2220
2150
2270
1004
266
240
92
206
3,68
4
2
4
94
66
4110
2220
2150
2410
1104
306
277
104
232
3,84
4
2
4
95
67
4110
2220
2150
2540
1204
344
311
116
266
3,93
4
2
4
95
67
4110
2220
2150
2700
0524
150
134
53
116
3,53
4
2
4
92
64
3110
2220
2150
1700
0604
166
149
58
127
3,64
4
2
4
92
64
3110
2220
2150
1840
0704
191
172
65
143
3,77
4
2
4
92
64
3110
2220
2150
1980
0804
220
198
77
167
3,57
4
2
4
94
66
4110
2220
2150
2310
0904
244
219
84
187
3,60
4
2
4
94
66
4110
2220
2150
2370
1004
274
248
92
206
3,82
4
2
4
94
66
4110
2220
2150
2520
1104
315
287
104
232
3,98
4
2
4
96
68
5110
2220
2150
2800
1204
356
322
121
266
3,80
4
2
4
97
69
5110
2220
2150
2940
as above, however temperature / noise optimized
Cooling operation up to -15 °C, Heating operation up to -10 °C outside temperature with LT model
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with warm water 40/45 °C and air intake temperature 7 °C
with chilled water 12/7 °C and air intake temperature 35 °C* in heating mode
Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLAH
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal heating capacity
Nominal cooling capacity
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLAH-LT
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal heating capacity
Nominal cooling capacity
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
32 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Heat pumps
5,7 kW up to 16,8 kWInside installation
air cooled · packaged · duct connection GSDH 0011 ... 0041 - ED5
GSDH 0021 ... 0061 - ED1
Space saving optimized configuration
with 1 scroll compressor
Heat pump switch using 4 way valve
Cooling operation up to -10 °C,
Heating operation up -7 °C outside temperature
Autoadaptive microprocessor control
Integated chilled water pump
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with warm water 40/45 °C and air intake temperature 7 °C
with chilled water 12/7 °C and air intake temperature 35 °C* in heating mode
Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GSDH
kW
kW
Pa
kW
A
Quantity
Quantity
Quantity
kPa
m³/h
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal heating capacity
Nominal cooling capacity
Max. external pressure
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Pump
Pump head piping
Nominal volume flow
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
1 ~ 230 Volt (Series ED5) 3 ~ 400 Volt (Series ED1)
0011
5,7
4,6
200
2,8
20,3
2,11
1
1
1
59
0,8
68
40
900
580
640
110
0021
6,5
5,4
100
2,9
20,3
2,37
1
1
1
57
1,0
68
40
900
580
640
115
0025
8,1
6,6
200
3,5
23,3
2,53
1
1
1
54
1,2
68
40
900
580
940
130
0031
10,0
8,2
80
4,2
27,3
2,48
1
1
1
54
1,5
68
40
900
580
940
135
0041
12,4
10,4
80
5,7
31,3
2,27
1
1
1
43
1,9
71
43
900
580
1240
180
0021
6,4
5,3
100
2,9
9,8
2,44
1
1
1
57
1,0
68
40
900
580
640
115
0025
8,0
6,7
200
3,3
10,3
2,62
1
1
1
54
1,2
68
40
900
580
940
135
0031
9,7
8,2
80
3,8
12,3
2,58
1
1
1
54
1,5
68
40
900
580
940
135
0041
12,8
10,8
80
5,9
14,3
2,36
1
1
1
40
2,0
71
43
900
580
1240
180
0051
14,4
12,6
80
6,1
16,1
2,40
1
1
1
33
2,3
71
43
900
580
1240
200
0061
16,8
14,6
70
6,5
19,3
2,62
1
1
1
30
2,7
71
43
900
630
1390
210
Supply voltage
PR-2008-0322-GB · Subject to modifications · Status 04/2008 33
Heat pumps
51 kW up to 428 kWInside installation
water cooled · packaged · without heat rejection GLWH 0152 … 0612 - BD2
GLWH 0604 … 1204 - BD2
Standard configuration with 2 scroll compressors
Heat pump switch using 4 way valve
Autoadaptive microprocessor control
Controller type: W3000 „B-version“ (0152-0612)
W3000 „L-version“ (0604-1204)
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 4 scroll compressors
0152
50,5
37,6
12,9
31
5,67
2
1
2
73
45
1055
649
1255
290
0182
58,2
43,9
14,3
33
5,86
2
1
2
74
46
1055
649
1255
305
0202
68,0
51,3
16,7
41
5,88
2
1
2
74
46
1055
649
1255
315
0252
77,0
57,8
19,2
45
5,59
2
1
2
74
46
1055
649
1255
325
0262
63,9
63,9
21,1
51
5,52
2
1
2
75
47
1055
649
1255
330
0302
100,9
76,2
24,7
56
5,54
2
1
2
76
48
1222
873
1496
585
0352
116,9
88,5
28,4
64
5,72
2
1
2
77
49
1222
873
1496
620
0412
132,1
99,9
32,2
72
5,61
2
1
2
77
49
1222
873
1496
660
0452
148,3
112,3
36,0
82
5,69
2
1
2
78
50
1222
873
1496
685
0512
165,4
125,4
40,0
92
5,66
2
1
2
78
50
1222
873
1496
740
0552
190,0
144,1
45,9
105
5,80
2
1
2
79
51
1222
873
1496
790
0612
214,7
162,9
51,5
118
5,70
2
1
2
79
51
1222
873
1496
830
0604
202
153
49
112
5,69
4
2
4
86
58
2227
877
1780
1090
0704
234
177
57
128
5,81
4
2
4
87
59
2227
877
1780
1165
0804
263
199
64
144
5,72
4
2
4
88
60
2227
877
1780
1245
0904
297
225
72
164
5,82
4
2
4
89
61
2227
877
1780
1290
1004
332
252
80
183
5,81
4
2
4
90
62
2227
877
1780
1395
1104
379
287
92
209
5,98
4
2
4
91
63
2227
877
1780
1500
1204
428
324
104
236
5,78
4
2
4
91
63
2227
877
1780
1585
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and warm water 40/45 °C Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLWH
kW
kW
kW
A
Anzahl
Anzahl
Anzahl
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal heating capacity
Nominal cooling capacity
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWH
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-410A
Nominal heating capacity
Nominal cooling capacity
Power consumption*
Max. current consumption
ESEER
Scroll compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWH 0401 … 0951 - BA2
GLWH 0802 … 1902 - BA2
Heat pumps
100 kW up to 509 kWInside installation
water cooled · packaged · without heat rejection
Standard configuration with 1 screw compressor
Control cabinet on lateral side
Selectable control of
Condenser water temperature (warm water)
Evaporator water temperature (chilled water)
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 2 screw compressors
0401
100
77
23
55
5,15
1
1
3
91
63
2300
1000
1500
800
0501
123
95
29
67
5,32
1
1
3
92
64
2500
1000
1500
840
0551
148
116
34
80
5,25
1
1
3
94
66
2500
1000
1500
1160
0651
168
131
39
92
5,29
1
1
3
94
66
2500
1000
1500
1180
0751
189
147
44
105
5,40
1
1
3
94
66
2500
1000
1500
1190
0851
223
175
51
115
5,54
1
1
3
94
66
3200
1000
1500
1270
0951
252
197
59
132
5,42
1
1
3
94
66
3200
1000
1500
1350
0802
202
158
47
111
5,39
2
2
6
94
66
3200
1200
1500
1470
1002
249
194
58
134
5,52
2
2
6
95
67
3200
1200
1500
1490
1102
287
223
67
161
5,24
2
2
6
97
69
3200
1200
1500
1930
1302
339
265
78
183
5,49
2
2
6
97
69
3500
1200
1800
2220
1502
387
304
88
210
5,67
2
2
6
97
69
3500
1200
1800
2260
1702
445
348
102
230
5,70
2
2
6
97
69
3500
1200
1800
2320
1902
509
397
117
264
5,61
2
2
6
97
69
3500
1200
1800
2720
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and cool water 40/45 °C Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLWH
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal heating capacity
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWH
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal heating capacity
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
34 PR-2008-0322-GB · Subject to modifications · Status 04/2008
available in July 2008
GLWH 1001 … 1801 - BA2
GLWH 2002 … 4802 - BA2
Heat pumps
274 kW up to 1374 kWInside installation
water cooled · packaged · without heat rejection
Standard configuration with 1 screw compressor
Control cabinet on front side
Selectable control of
Condenser water temperature (warm water)
Evaporator water temperature (chilled water
Autoadaptive microprocessor control
Controller type: W3000 „XL-version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 2 screw compressors
1001
274
215
62
132
5,49
1
1
3
94
66
2800
900
1735
1610
1201
323
254
73
165
5,87
1
1
3
97
69
3600
900
1750
2070
1301
362
286
80
184
5,42
1
1
3
97
69
3600
900
1750
2100
1351
408
324
89
208
5,82
1
1
3
97
69
3600
900
1750
2120
1601
477
377
105
235
5,71
1
1
3
97
69
3600
900
1950
3160
1801
547
430
124
272
5,86
1
1
3
97
69
3600
900
1950
3180
2002
519
409
116
263
5,76
2
2
6
97
69
3600
1120
1900
3050
2402
639
502
145
329
5,96
2
2
6
99
71
3600
1150
1900
3680
2602
726
573
161
367
5,59
2
2
6
99
71
4500
1150
1900
4000
2702
824
655
178
416
6,00
2
2
6
99
71
4500
1150
1900
4040
3202
935
736
210
470
5,77
2
2
6
99
71
4500
1150
1900
5160
3602
1090
855
249
544
5,98
2
2
6
99
71
4500
1150
2150
5850
4202
1231
971
274
620
5,56
2
2
6
99
71
4500
1150
2150
6270
4502
1303
1030
288
661
5,82
2
2
6
99
71
4500
1150
2150
6320
4802
1374
1089
302
702
6,06
2
2
6
99
71
4500
1150
2150
6360
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and cool water 40/45 °C Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLWH
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal heating capacity
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWH
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal heating capacity
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
PR-2008-0322-GB · Subject to modifications · Status 04/2008 35
available in July 2008
GLWH 5003 … 5403 - BA2
GLWH 5414 … 9604 - BA2
36 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Heat pumps
1463 kW up to 2749 kWInside installation
water cooled · packaged · without heat rejection
Standard configuration with 3 screw compressors
Control cabinet on front side
Selectable control of
Condenser water temperature (warm water)
Evaporator water temperature (chilled water)
Autoadaptive microprocessor control
Controller type: W3000 „XL-Version“
Master/slave operation with units of
W3000 series as accessories available
Connection to BMS via optional interface
as above, however with standard configuration with 4 screw compressors
5003
1463
1147
333
742
5,79
3
3
6
101
73
4500
1700
2100
7890
5203
1545
1212
352
779
5,89
3
3
6
101
73
4500
1700
2100
7930
5403
1613
1260
373
816
5,91
3
3
6
101
73
4500
1700
2100
7960
5414
1647
1310
356
832
6,00
4
4
8
102
74
4500
2250
2050
8280
5904
1759
1392
387
886
5,87
4
4
8
102
74
4500
2250
2050
9380
6404
1899
1501
421
940
5,86
4
4
8
102
74
4500
2250
2250
11410
6804
2041
1606
459
1014
5,93
4
4
8
102
74
4500
2250
2250
11460
7204
2181
1710
467
1088
5,98
4
4
8
102
74
4500
2250
2250
11520
7804
2322
1827
522
1164
5,74
4
4
8
102
74
4500
2250
2250
11930
8404
2462
1942
548
1240
5,56
4
4
8
102
74
4500
2250
2250
12350
9004
2606
2060
575
1322
5,82
4
4
8
102
74
4500
2250
2250
12430
9604
2749
2749
603
1404
6,06
4
4
8
102
74
4500
2250
2250
12520
ESEER European Seasonal Energy Efficiency according to Eurovent standard 6-C003-2006Performance data with chilled water 12/7 °C and cool water 40/45 °C Sound power level EUROVENT certified value, definition as of ISO 3744Sound pressure level Hemispherical radiation – 10m distance – without reflection
For project related sound data calculations use the obligatory sound power level (see also page 39)!
GLWH
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal heating capacity
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
GLWH
kW
kW
kW
A
Quantity
Quantity
Quantity
dB(A)
dB(A)
mm
mm
mm
kg
refrigerant R-134a
Nominal heating capacity
Nominal cooling capacity
Power consumption
Max. current consumption
ESEER
Screw compressor
Circuits
Speeds
Sound power level
Sound pressure level 10 m
Length
Width
Height
Operating weight
available in July 2008
PR-2008-0322-GB · Subject to modifications · Status 04/2008 37
All configurations
at a glance
Cooling/
Heating capacity
Page
Type
kW
Space saving optimized model
Outside installation – air cooled
Packaged
Noise optimized model – SL
High efficient optimized configuration
GACP – integrated pump
GACB – integrated pump + buffer tank
Pump optional
Pump integrated
Buffer tank and pump optional
Buffer tank and pump integrated
Split – without evaporator
Necessary obligatory accessories
Expansion valve kit GZCA…AD.R12
Communication box GZCAGFCAD.E13
Inside installation
air cooled – packaged –
for duct connection
air cooled – split –
without condenser –
water cooled – packaged –
without heat rejection
Heat pump configuration
Heat pump switch with 4 way valve
Temperature/noise optimized – LT
GAHP – integrated pump
GAHB – integrated pump + buffer tank
Pump optional
Pump integrated
Buffer tank and pump as option
Heat. operation up to -5°C outside temp.
Heat. operation up to -7°C outside temp.
Heat. operation up to -10°C outside temp.
Heat. operation up to -10°C outside temp. - LT
Cool. operation up to -5°C outside temp.
Cool. operation up to -15°C outside temp.
Cool. operation up to -10°C air intake temp.
Axial fans
Centrifugal fans for external pressure
Scroll compressor – fully hermetic
Scroll compressor with inverter technology
Screw compressor – semi-hermetic
refrigerant R-134a
refrigerant R-407C
refrigerant R-410A
Microprocessor controls
Autoadaptive microprocessor controls
Connection to BMS via optional interface
Controls by others
Water filter supplied
Flow switch supplied
Eurovent certification
0061
024
0612
1204
1301
2642
2632
2702
4822
8404
250
0604
0061
010
1204
024
0604
024
1204
1902
4802
9604
0611
024
0612
1204
0061
1204
1902
4802
9604
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
0011
005
0152
0524
0751
1542
1532
1502
2712
5403
100
0152
0011
005
0152
005
0152
005
0152
0401
1001
5003
0011
005
0152
0524
0011
0152
0401
1001
5003
GS
AC
GA
CN
GC
A
GLC
U
GS
DC
GD
C
GLD
C
GR
C
GLR
C
GW
C
GS
AH
GA
HN
GLA
H
GLA
H
GS
DH
GLW
H
GLW
H
GLW
H
GLW
H
5
11
36
136
145
277
277
294
625
1198
12
40 5
12
37
12
40
13
43
87
233
1283 6
12
43
145 6
51
98
270
1439
15
55
159
325
266
516
516
598
1157
1744
28
171
15
24
312
62
162
65
371
447
1216
2432
17
54
173
356
17
428
500
1351
2702
GLAC GLWC
6 7 16 17 18 198 9 10 11 12 13 14 15 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
• • • • • • • • • •
• • • • • • • • • • • • • • • •
• • • • • • • • • • • • • •
SL SL SL SL SL SL SL SL
• • •
P
B
• •
• •
• • •
•
• •
•
•
•
• • • • • • • • • • • • • • •
• • • •
• •
• • • • • • • • •
• • • • • • • • •
• • • • • •
LT LT
P
B
• •
• •
• •
• •
• •
•
LT LT
•
• • • • • • • • • • • • •
• • • • • •
• • • • • • • • • • • • • • • •
• • • •
• • • • • • • • • • • • • • • • • • •
•
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • •
• • • • • • • • • • • •
• • • • •
• • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • •
• •
• • • • • • • • • •
• • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • •
38 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Accessories
Controller
Features of our chiller controller of G and GL series
Following controller functions are available as standard:
Remote On/Off contact, collective fault messaging
Remote switch between heating/cooling mode
General status/operating messaging
Status messaging of individual compressors
Chilled water pump control
Besides, following controller functions are additional and are available as option:
Soft start of compressors
Connection to Building Management System
Connection for remote control
Following controller functions are available as standard:
Alphanumerical display
Remote On/Off contact
Collective fault messaging
Remote switch between heating/cooling mode
Chilled water pump control
P-I temperature control at inlet and outlet
Retrieving last 200 alarm messages with history
Besides, following controller functions are additional and are available as option:
Setpoint shifting via 4-20 mA signal
Load shedding contact
Error switch off by others
Connection for remote control
Soft start of compressors
Status messaging of compressors
Connection to Building Management System
Master/slave operation with up to 5 units
Following controller functions are available as standard:
As with W3000 B-version with additional
Setpoint shifting via 4-20 mA signal
Error switch off by others
Besides, following controller functions are additional and are available as option:
As with W3000 B-version with additional:
2-nd setpoint
Following controller functions are available as standard:
As with W3000 B-version with additional
Continuous capacity control of screw compressors
Without chilled water pump control
Besides, following controller functions are additional and are available as option:
As with W3000 B-version with additional:
2-nd setpoint
Chilled water pump control
µ-chiller
W3000 „L-version“
W3000 „B-version“
W3000 „XL-version“
79 dB(A) Sound power level : Can be measured but not perceived. Like heating capacity of a heating element. 58 dB(A) Sound pressure level: Can be measured and perceived. Like room temperature increase by heating element.
Sphere radiation
Quarter sphere radiation
Hemisphere radiation
Distance from sound source
–
–
-25 dB
-30 dB
-40 dB
-50 dB
-22 dB
-15 dB
-10 dB
PR-2008-0322-GB · Subject to modifications · Status 04/2008 39
Sphere
Radiation factor 1
Only theoretical value
Hemisphere
Radiation factor 2
Quarter sphere
Radiation factor 4
Example
79 dB(A) Sound power level
-28 dBHemisphere radiation in 10 m distance
– reflection freei
+7 dB Reflections
58 dB(A) Sound pressure level
Reflections This imaginary figure has to be adapted to local conditions
Sound pressure level relates to point-like sound source
40 PR-2008-0322-GB · Subject to modifications · Status 04/2008
Notes
PR-2008-0322-GB · Subject to modifications · Status 04/2008 41
Notes
Customer proximity, sales structures
Reachable always and everywhere!
www.gea-air-eco2nomy.com
GEA Klimatechnik
GmbH & Co KG
A-4673 Gaspoltshofen
Tel. +43 / 7735 / 8000-0
GEA Happel Belgium N. V.
B-1130 Brussels
Tel. +32 / 2 / 2406161
EVISS Ltd.
BG-7000 Rousse
Tel . +359 / 82 / 81000
GEA Klimatehnika
RS-11070 Novi Beograd
Tel. +381 / 11 / 3193955
GEA Klimatechnik UAB
LT-01141 Vilnius
Tel. +370 / 5 / 2106060
ATC Klimatec Schweiz AG
CH-3065 Bolligen-Station
Tel. +41 / 31 / 9171919
GEA LVZ, a.s.
CZ-46312 Liberec
Tel. +420 / 48 / 5225-111
GEA Klimatizace spol. s r.o.
CZ-46312 Liberec
Tel. +420 / 48 / 5225-303
GEA Happel
Klimatechnik GmbH
D-44625 Herne
Tel. +49 / 2325 / 468-00
GEA Happel
Wieland GmbH
D-44625 Herne
Tel. +49 / 2325 / 468-754
GEA Delbag
Lufttechnik GmbH
D-44625 Herne
Tel. +49 / 2325 / 468-700
GEA Delbag-Luftfilter
Vertriebsgesellschaft mbH
D-10709 Berlin
Tel. +49 / 30 / 43592-3
GEA Klimateknik ApS
DK-2610 Rødovre
Tel . +45 / 38 / 887070
GEA Air Treatment
Marketing Services Int.
GmbH – oficinaEspaña
E-28036 Madrid
Tel. +34 / 91 / 3837701
GEA Klimatechnik UAB
LT-01141 Vilnius
Tel. +370 / 5 / 2106060
GEA Delbag
Filtration d l‘air
F-77450 Montry
Tel. +33 / 1 / 60043355
GEA Happel France sarl
F-59436 Roncq Cedex
Tel. +33 / 3 / 20689020
OY TEKNOCALOR AB
FIN-01300 Vantaa
Tel. + 358 / 9 / 82546020
GEA Denco Ltd.
UK-HR4 8DS Hereford
Tel. +44 / 1432 / 277 277
GEA Klimatechnika Kft
H-1037 Budapest
Tel. +36 / 1 / 4393200
GEA Klima-rashladna
tehnika d.o.o.
HR-10000 Zagreb
Tel. +385 / 1 / 6064900
Aspect Environmental Ltd.
Ardee, Co. Louth Ireland
Tel. +353 / 41 / 6858983
Rafn Jensson
IS-110 Reykjavik
Tel. +354 / 56 / 780-30
GEA Happel Luxembourg
L-4940 Bascharage
Tel. +352 / 26 / 502970
GEA Klimatechnik UAB
LT-01141 Vilnius
Tel. +370 / 5 / 2106060
GEA Klimatechnik UAB
LT-01141 Vilnius
Tel. +370 / 5 / 2106060
GEA Klimatehnika
RS-110 70 Novi Beograd
Tel. +381 / 11 / 3193955
GEA Klimaprodukter AS
N-0484 Oslo
Tel. +47 / 220 / 27990
GEA Happel Nederland B.V.
NL-2909 LL
Capelle a/d Ijssel
Tel. +31 / 10 / 2350606
Nónio, Lda.
P-1269-090 Lisboa
Tel. +351 / 21 / 3826160
GEA Klimatyzacja Sp. z o.o.
PL-54610 Wroclaw
Tel. +48 / 71 / 3737952
GEA Klimatechnik s.r.l.
RO-300222 Timisoara
Tel. +40 / 356 / 423703
GEA Kondicioner Moskva
RU-105094 Moskva
Tel. +7 / 495 / 9566674
GEA EXOS Ventilation AB
S-74528 Enköping
Tel. +46 / 171 / 85530
GEA Klimatizácia s.r.o.
SK-83104 Bratislava
Tel. +421 / 7 / 44457917
GEA Klimatizacijska
Tehnika d.o.o.
SI-1000 Ljubljana
Tel. +386 / 1 / 2573850
GEA Klimatehnika
RS-11070 Novi Beograd
Tel. +381 / 11 / 3193955
GEA ISISAN
TR-80700
Balmumcu Istanbul
Tel. +90 / 212 / 2757171
GEA Ukraina t.o.v.
UA-01135 Kyiv
Tel. +38 / 044 / 4619356
PL
RO
RUS
S
SK
SLO
SRB
TR
UA
LV
DK
E
EST
F
FIN
GB
A
B
BG
BIH
BY
CH
CZ
CZ
D
PR -2
008
-032
2 - G
B
Subj
ect
to m
odifi
catio
n Is
sue
04 /2
008
C
opyr
ight
GEA
Air
Trea
tmen
t
P
IE
IS
L
MWE
N
NL
HR
H
F
D
D
D
LT
The complete addresses are available on the Internet under: www.gea-air-eco2nomy.com.