en1092

18
EN1092-1 法兰标准 Flanges PN 6 EN 1092-1 Dimensions of PN 6 Flanges EN 1092-1 NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange. NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1 ".

Upload: le-wang

Post on 13-Nov-2014

1.949 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: EN1092

EN1092-1 法兰标准

Flanges PN 6 EN 1092-1

Dimensions of PN 6 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.

NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1".

Page 2: EN1092

Dimensions in mm

Page 3: EN1092

* Above DN 600 dimension C1 is to be specified by the purchaser.

** For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The

p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.

Page 4: EN1092

Flanges PN 10 EN 1092-1

Dimensions of PN 10 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.

NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1".

Page 5: EN1092

Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,

Page 6: EN1092

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The

p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.

Page 7: EN1092

Flanges PN 16 EN 1092-1

Dimensions of PN 16 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.

NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1".

Page 8: EN1092

Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,

** 8 holes is preferred however 4 holes may be supplied upon special request by the purchaser.

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The

p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.

Page 9: EN1092

Flanges PN 25 EN 1092-1

Dimensions of PN 25 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.

NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1".

Page 10: EN1092

Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The

p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.

Page 11: EN1092

Flanges PN 40 EN 1092-1

Dimensions of PN 40 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.

NOTE 2: For d1 dimensions see document "Flange facing according to EN 1092-1".

Page 12: EN1092

Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,

Page 13: EN1092

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between

the manufacturer and the purchaser.

Flanges PN 63 EN 1092-1

Dimensions of PN 63 Flanges EN 1092-1

NOTE: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.

Page 14: EN1092

Dimensions in mm

Page 15: EN1092

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between

the manufacturer and the purchaser.

Flanges PN 100 EN1092-1

Dimensions of PN 100 Flanges EN 1092-1

Page 16: EN1092

NOTE: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.

Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,

Page 17: EN1092

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to and including DN 600. The p/t rating of all other flanges shall be agreed between

the manufacturer and the purchaser.

FLANGES according to EN 1092-1

Flange facing dimensions according to EN 1092-1 standard

Type A

flat face

Type B

raised face

Type C

tongue face

Type D

groove face

Page 18: EN1092

Type E

spigot

Type F

recces

Type G

O ring recess

Type H

O ring groove

* For PN 160 flnages form can be only B2, C and D