    NetXtend

     Cell Site SeriesIntegrated Enclosure Solution

    Outside Plant for

    Business-Critical Continuity ™  

  • 8/18/2019 Emmerson Battery cabinet

    2/12

    2

    In the race to attract customers by pro-viding more mobile services and greater

    data transfer, wireless carriers mustquickly embrace and deploy ever-moresensitive networking technology at theircell sites. As the industry moves steadilytoward LTE (Long Term Evolution) andother 4th generation mobile broadbandstandards, both carriers and OEMs arelooking for the fastest ways to get thisequipment up and running, and keep it atpeak performance to maintain customersatisfaction and protect their revenuestreams.

    Emerson’s NetXtend™ Cell Site Series of

    integrated enclosures provides customcell site deployment solutions for elec-tronic equipment by utilizing common

    structures and components. This uniqueseries of cabinets offers multiple, field-

    configurable chambers and temperaturecontrolled environmental zones withina single enclosure to provide the idealenvironment for each piece of equip-ment. Battery backup assures continuedoperation when commercial power isinterrupted.

    By eliminating the need for permittingand construction of shelters, field-configurable NetXtend™ Cell Site Seriesenclosures reduce deployment cycles andalso provide flexibility for the inevitableconfiguration changes that next-gen-

    eration mobile broadband technologydemands.

     

    Features & Benefits

    n  Positive pressure airflow

    design — maintains a clean and

    safe environment for network

    electronics

    n  Single, configurable platform

    design — meets all your DC

    power, radio and battery

    requirements

    n  Unique temperature con-

    trolled zones — individual

    compartments provide optimal,

    Freon-free cooling with long

    term utility savings

    n  Adjustable multi-chamber

    design — internal panels enable

    custom thermal solutions while

    maximizing rack space

    n  Single-point control system —combines thermal control,

    power access and alarm

    monitoring

    n  Reversible chamber doors —

    provide easy access in stringent

    deployment areas

    n  Low maintenance — maximizes

    reliability, minimizes utility costs

    n  360° top cable access with

    Roxtec® entrance boots —

    optimizes site cabling andprevents water intrusion

    n  Multiple cabinet deployment —

    minimizes site lease costs and

    maximizes configuration flexibility

    n  GR-487 and Seismic Zone

    4 tested — to meet industry

    safety standards

    NetXtend™ Cell Site Enclosures —A quick and cost-effective way to deploy and pro-

    tect the latest mobile networking technology

  • 8/18/2019 Emmerson Battery cabinet

    3/12

    Easily configurable, these enclosures support

    distributed BTS applications, as well as power and battery

    back-up deployments. 

    1

    1

    2

    1

    4

    3

    5

    9

    10

    6

    7

     1  Thermoelectric Cooler

     2  Forced Air Ventilator

     3  RF Equipment Racks (19-in.)

     4  -48V Distribution Panel

     5  DC-DC Converter Shelf 

     6  Battery Shelf 

     7  Mounting Plinth (optional)

     8  Exhaust Vent

     9  Removable Access Panel 

    10 Removable Access Panel

    Battery Cabinet (front) Power Cabinet (back)

    8

  • 8/18/2019 Emmerson Battery cabinet

    4/12

    4

    Roof Panel

    The roof panel is removable to provide

    access to internals for cabling and

    maintenance. The panel is alarmed to

    prevent unknowingly leaving the panel

    open after ser vicing the equipment. An

    audible alarm alerts the technician on

    the site, and the alarm is also communi-cated to the NOC (Network Operations

    Center), should the technician leave the

    site without securing the panel.

    Walls, Panels & Doors

    Modular panels and doors are combined

    to create divided chambers within

    the enclosure that provide different

    thermal zones to satisfy OEM equip-

    ment environmental needs. After initial

    deployment, as technology evolves and

    equipment changes, chambers can beexpanded or decreased in the field by

    moving partitions, rather than requiring

    complete enclosure replacement.

    Doors with gaskets are designed to

    hinge from either side and can be

    changed from one side to the other in

    the field to accommodate the space

    requirements of the installation.

    Exterior panels are aluminum. The inner

    frame--the main struc tural component-

    -is steel. All surfaces are protected with

    our patented multistage powder fin-

    ishing process to meet EPA standards.

    The finish meets GR-487 requirements,

    including salt fog.

    Racks and Accessories

    NetXtend™ Cell Site enclosures are built

    with 23" equipment racks. 23" to 19"

    adapters are available to support dif-

    ferent OEM equipment such as RxAIT

    (Receive Antenna Interface Tray) equip-

    ment, distributed BTS systems, and other

    RF and power distribution components.

    Mounting

    NetXtend™ Cell Site Series enclosures are

    designed for pad or grate mounting. An

    optional mounting plinth is available with

    six bolt locations. Installation of bolts in

    all six positions meets requirements for

    Zone 4 seismic applications.

    Enclosure Flexibility

    NetXtend™ Cell Site Series enclosures enable you to quickly and economically create

    the ideal operating environment for each sensitive electronic component — without

    designing and fabricating a unique enclosure for every site and every application.

    Plus, once an enclosure is deployed, it can be reconfigured in the field to accommo-

    date new equipment and new requirements.

  • 8/18/2019 Emmerson Battery cabinet

    5/12

    Climate Control Solutions

    Whatever climate or heat dissipation requirements may arise, there is a cli-

    mate control solution available to keep your equipment operating within its

    optimum temperature range. Options include a variety of environmentally

    friendly solutions such as positive-pressure forced air cooling, Freon-free

    thermoelectric coolers, heat exchangers, fan cooling, convection cooling and

    combinations of the above to meet more dynamic requirements.

    The integrated Environmental Control Unit (ECU) monitors conditions in

    each chamber and provides power controls and alarms to/from the appli-

    cable thermal components. Climate control systems are integrated into

    the door or panels at the factory and are field configurable by adjusting the

    software in the ECU to accommodate changes in thermal requirements of

    contained equipment.

    Battery Choices

    Battery backup assures continued operation during loss of commercial

    power, keeping your cell site up and running and keeping your revenue

    stream flowing. NetXtend™ Cell Site Series enclosures are available with -48V

    and +24V battery shelf options. Cabinets can hold up to 20 batteries by com-

    bining chambers, while still meeting Seismic Zone 4 requirements. Battery

    shelf compartments are isolated from electronics compartments to allow for

    optimum thermal zones for each type of equipment in the cabinet.

  • 8/18/2019 Emmerson Battery cabinet

    6/12

    6

    Power Cabinet

    Specifications — Power Cabinet

    Thermal Solutions

      Power Chamber Forced Air – Positive Pressure11-22 RU available space

      Ancillary Equipment Chamber Thermoelectric Cooler – 200W0-18 RU available space

      Battery Chamber Thermoelectric Cooler – 200W0-21 RU available space

    NOTE: Combine the center and bottom chamber to house up to 3 shelves of batteries.

    Equipment

      Optional Auto Transfer Switch 200/200 A

      Generator Connection Micrin® Cam-Lok

      Ground Bar 10 positions

      Terminal Block 50-pair Phoenix® block

    Ordering Information — Power Cabinet

    EmersonPart No.

     Description

     DC Power System

     Rack Space

    Dimensions(H x W x D)

    F2009270 +24V Power Cabinet NetSure® 700 DC Power System 42 RU 86" x 32" x 31"

    F2008213 +24V Power Cabinet e/w ATS NetSure® 700 DC Power System 42 RU 86" x 32" x 31"

    F2009274 -48V Power Cabinet NetSure® 701 DC Power System 42 RU 86" x 32" x 31"

    F2009275 -48V Power Cabinet e/w ATS NetSure® 701 DC Power System 42 RU 86" x 32" x 31"

    NetXtend™ Cell Site Power Cabinets offerthree sealed chambers for DC power,ancillary equipment and batteries. The DCpower chamber is configured with eithera +24V NetSure® 700 system or a -48VNetSure® 701 system. The center and bot-tom chambers can be combined to house

    additional batteries, if desired. The cabi-net comes equipped with a 10-positionground bar and 50-pair Phoenix® terminalblock. Two optional 200/200A automatictransfer switches can be mounted to theside of this cabinet.

  • 8/18/2019 Emmerson Battery cabinet

    7/12

    NetXtend™ Cell Site Battery Cabinets areequipped with five battery shelves. Thiscabinet houses up to (10) +24V or (5)-48V battery strings. The cabinet includes

    Battery Cabinet

    Specifications — Battery Cabinet

     Battery String Capacity (10) +24V Strings Max

    or (5) -48V Battery Strings

      Thermal Solution (2) 200 Watt Thermoelectric Coolers

      Ground Bar 10 positions

      Terminal Block 12-pair Phoenix® block

    Ordering Information — Battery Cabinet

    EmersonPart No.

     Description

     Rack Space

    Dimensions(H x W x D)

    F2008214 +24V Battery Cabinet e/w 5 battery shelves 42 RU 86" x 32" x 31"

    F2008250 -48V Battery Cabinet e/w 5 battery shelves 42 RU 86" x 32" x 31"

    a 10-position ground bar and 12-pairPhoenix® terminal block. Two 200 wattthermoelectric coolers are mounted onthe exterior.

  • 8/18/2019 Emmerson Battery cabinet

    8/12

    8

    The Distributed BTS Site Support Cabinetis designed with a reversible front/backdoor for easy access in stringent deploy-ment areas. This cabinet can be equippedwith DC-DC converters, power distribu-tion, battery shelves and a mounting

    Distributed BTS Site Support Cabinet

    Specifications — Distributed BTS Site Support Cabinet

      Reversible Front/Back Door Yes

      Weight 990 lbs.

      Battery String Capacity (4) +24V Strings Max

      Thermal Solution (2) 200 Watt Thermoelectric Coolers

    Ground Bar 10 positions

      Terminal Block 12-pair Phoenix® block

      Converters Order separately

    Ordering Information — Distributed BTS Site Support Cabinet

    EmersonPart No.

     Description

     Rack Space

    Dimensions(H x W x D)

    F2008242 +24V Distributed BTS Site Support Cabinet e/w DC-DC converter shelf,-48V distribution panel, battery shelf and mounting plinth

    42 RU 90" x 32" x 31"

    F2009280 -48V Distributed BTS Site Support Cabinet, e/w distribution panel,battery shelf and mounting plinth

    42 RU 90" x 32" x 31"

    plinth. Also included are a 10-positionground bar and a 12-pair Phoenix® terminal block. Two optional 200 wattthermoelectric coolers are mounted onthe exterior. Converters are easily accom-modated but must be ordered separately.

  • 8/18/2019 Emmerson Battery cabinet

    9/12

    Distributed BTS Cabinet (front) Distributed BTS Cabinet (back)

  • 8/18/2019 Emmerson Battery cabinet

    10/12

    10

    NetXtend™ Cell Site Series enclosures uti-

    lize Emerson Network Power’s NetSure® 

    DC power technology platform to

    ensure the reliability of every active OSP

    enclosure. Emerson Network Power has

    been an industry leader in power solu-

    tions since 1909, with real-world, global

    knowledge of all types of telecom DC

    power needs.

    Compact, modular, NetSure® DC power

    systems provide more space for revenue-

    generating equipment in the enclosure

    and can be configured for 19" or 23" rack

    mounting. They deliver constant power

    to meet load or recharge demand, and

    comply with global standards.

    AC Distribution / ATS

    DC Power Integration

    Units are available to provide -48V and

    +24V power. They operate on 120 or

    220V single-phase AC power, 50 or 60

    Hz, to accommodate global differences.

    Remote access options allow users to

    view, control and interact with installa-

    tions where suitable communication links

    are available.

    To assure reliable transfer of business-critical loads to emergency sources

    and provide over-current protection and surge protection, an Automatic

    Transfer Switch (ATS) can be mounted directly on the enclosure or separately

    mounted on an H frame or other arrangement at the cell site.

    Emerson’s ASCO® 7000 Series switches combine best-in-class technology

    from world-class manufacturers with a comprehensive offering of options

    and capabilities. Key features include commercial and generator power

    breakers, a 42-position Square D load center, customer-specified TVSS

    (Transient Voltage Surge Suppression) and a generator receptacle or cam-lokassembly for engine-generator connections.

    If cabinet mounting is specified, the ATS is mounted on the cabinet at the

    factory. ASCO® ATS units are UL 1008 certified and meet NFPA and NEC

    requirements for emergency and standby power systems.

  • 8/18/2019 Emmerson Battery cabinet

    11/12

    To be profitable, your wireline and wire-

    less networks must be properly deployed

    and individual sites must perform reliably,

    night and day. Emerson Network Power

    understands this and offers a wide array of

    global installation and support services.

    The local presence of a global organization

    Emerson Network Power has the industry

    experience and in-house product knowl-

    edge to recommend, engineer, integrate,

    implement and support NetXtend™ Cell

    Site Series enclosures that you can con-

    fidently deploy as your network grows.

    Enclosure Assembly, Integration and Testing

    Emerson Network Power 

     provides a complete range of communications

    network infrastructure solutions and services

    built on an industry-leading reputation for 

    quality, reliability and value

    When we configure a new Cell Site Series

    enclosure in one of our regional configu-

    ration centers, we integrate the climate

    control, DC power and backup, alarms,

    accessories and customer equipment.

    Prior to production, a skilled test team

    operates the completed enclosure in our

    thermal and acoustic chambers. If nec-

    essary, we modify the configuration to

    reduce the chance of encountering any

    unexpected glitches once the units are

    installed in the field.

    Our experienced technicians will conduct

    site surveys of your current installations,

    and recommend and engineer the neces-

    sary enclosure and power solutions to

    accomplish your goals. We will prepare

    prints and other documentation and

    pre-stage and configure all equipment to

    assure efficient installation. We will install

    and test enclosures and power systems

    prior to going on line. And we will provide

    post-installation maintenance contracts

    and emergency services to keep all sys-tems running efficiently.

    In short, you can focus on keeping your

    customers connected, knowing you have

    Emerson Network Power global service

    coverage, with over 150 service locations

    worldwide and 2,000 certified profes-

    sionals with local knowledge behind you.

  • 8/18/2019 Emmerson Battery cabinet

    12/12

    © 2010 Emerson Network Power Energy Systems, North America, Inc. All rights reserved.

    Emerson Network Power.The global leader in enabling Business-Critical Continuity ™ .

    AC Power

    Connectivity

    Outside Plant Racks & Integrated Cabinets

    ServicesPower Switching & Controls

    Surge Protection

    Emerson Network PowerEnergy Systems, World Headquarters4350 Weaver Parkway, Warrenville, IL 60555 USAToll Free: 800-800-1280 (USA and Canada)Telephone: 440-246-6999 Fax: 4 40-246-4876Web: EmersonNetworkPower.com/EnergySystems

    Emerson (NYSE: EMR), based in St. Louis, Missouri (USA), is a global leader in bringing technology and engineering

    together to provide innovative solutions for customers in industrial, commercial, and consumer markets through its

    network power, process management, industrial automation, climate technologies, and appliance and tools businesses.For more information, visit: Emerson.com.

    Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity ™  

    from grid to chip for telecommunication networks, data centers, health care and industrial facilities. Emerson Network

    Power provides innovative solutions and expertise in areas including AC and DC power, precision cooling, embedded

    computing and power, integrated racks and enclosures, power switching and controls, infrastructure management, and

    connectivity. All solutions are supported globally by local Emerson Network Power service technicians. For more

    information on Emerson Network Power’s full suite of solutions specifically supporting the communications network

    infrastructure, including NetSpan™, NetReach™ and NetXtend™ outside plant enclosures and equipment, NetSure® DC

    power systems, and NetPerform™ Optimization, Design & Deployment services, visit:

    EmersonNetworkPower.com/EnergySystems.

    Learn more about Emerson Network Power products and services at: EmersonNetworkPower.com.

    This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be

    used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson

    Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service.

    Emerson®, Emerson Network Power™, Business-Critical Continuity™, ASCO®, NetSpan™, NetReach™, NetXtend™ and NetSure® are trademarks of Emerson Electric Co.

    and/or one of its subsidiaries.

    Additionally, this brochure references the following company trademarks: Phoenix®, Micrin® and Roxtec®. Names of companies and products are trademarks or registered

    trademarks of the respective companies. Any questions regarding usage of trademark names should be directed to the original manufacturer.

    J 2010C d OSP 128650