emc unity™ family release notes
TRANSCRIPT
Release Notes
Dell EMC Unity™ Family
Dell EMC Unity All Flash, Unity Hybrid,UnityVSAVersion 4.2.1.9535982
Release Notes302-002-57216October 2017
These release notes contain supplemental information about this Unity release.
l Revision history...................................................................................................... 2l Product description................................................................................................ 2l New and enhanced features................................................................................... 3l Unity File Storage Resource Adapter (SRA) support.............................................. 5l Fixed issues............................................................................................................ 5l Fixed in previous releases...................................................................................... 14l Known issues........................................................................................................ 53l Limitations............................................................................................................ 72l Environment and system requirements................................................................. 73l Software media, organization and files..................................................................73l Installing and enabling language packs.................................................................. 75l Unique identifier for UnityVSA..............................................................................75l New and enhanced feature details........................................................................ 75l Additional resources............................................................................................. 83
Revision history
Table 1 Unity release notes revision history
Revision Date Description
16 October 2017 Release 4.2.1.9535982
15 October 2017 Release 4.2.0.9476662 with new features includedfrom 4.2.0.9392909.
14 August 2017 Release 4.2.0.9476662
13 July 2017 Release 4.2.0.9392909
12 April 2017 Release 4.1.2.9257522
11 February 2017 Release 4.1.1.9138882
10 January 2017 Release 4.1.0.9058043
09 December 2016 Release 4.1.0.8959731 (upgrade only) Release4.1.0.8940590
08 November 2016 Release 4.0.2.8627717
07 October 2016 Documentation update only - ESRS Requirements.
06 September 2016 Release 4.0.1.8404134
05 September 2016 Release 4.0.1.8320161
04 August 2016 Release 4.0.1.8194551
03 July 2016 Documentation update only
02 June 2016 Localization information
01 May 2016 Initial release, 4.0.0.7329527
Product descriptionLearn about the Unity Family.
The Unity Family product line sets new standards for midrange storage with acompelling simplicity, a modern design, affordable prices, and flexible deployment - tomeet the needs of resource-constrained IT professionals in large or small companies.
Unity is targeted for mid-sized deployments, remote or branch offices, and cost-sensitive mixed workloads. Unity systems are designed for all-Flash, deliver the bestvalue in the market, and are available in purpose-built (all Flash or hybrid Flash),converged deployment options (through VCE), and a software-defined virtual edition.With simplified ordering, all-inclusive software, new differentiated features, internet-enabled management, and a modern design, Unity is where powerful meets simplicity.
The Unity Family consists of:
l Unity (purpose built): A modern midrange storage solution, engineered from theground-up to meet market demands for Flash, affordability, and incrediblesimplicity. The Unity platform is available in 4 All Flash models and 4 Hybridmodels.
Release Notes
2 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
l VBlock (converged): Unity storage options are available in VxBlock System 350.
l UnityVSA (virtual): The Unity Virtual Storage Appliance (VSA) allows theadvanced unified storage and data management features of the Unity family to beeasily deployed on a VMware ESXi server, for a ‘software defined’ approach.UnityVSA is available in two editions:
n Community Edition is a free downloadable 4 TB solution recommended for non-production use.
n Professional Edition is a licensed subscription-based offering available atcapacity levels of 10 TB, 25 TB, and 50 TB. The subscription includes access toonline support resources, EMC Secure Remote Support (ESRS), and on-callsoftware- and systems-related support.
All three deployment options, i.e. Unity, UnityVSA, and Unity based VBlocks, enjoy onearchitecture, one interface with consistent features and rich data services.
Unity is Redefining Storage Simplicity and ValueUnity is the only storage system that successfully meets four important storagerequirements of today’s midmarket IT professionals (simple, modern, affordable,flexible). Here are some of the features and supporting statements that allows Unityto redefine midrange storage:
l Simple: Simplified ordering, all-inclusive software, rack-and-stack in less than 2minutes, customer installable, a new slick HTML5 user interface, proactive assist,and new CloudIQ internet-enabled management.
l Modern: Unity is designed to support the latest dense Flash drives such as 3D TLCNAND with a Linux-based architecture, new Intel Haswell multicore processors, upto 295K IOPS, 2U dense configurations, scalable 64bit file system & file systemshrink, unified snapshots & replication, Data-at-Rest-Encryption (D@RE), supportfor public and private cloud access, deep ecosystem integration with VMware(native VVols) and Microsoft, and much more.
l Affordable: Unity delivers the best midrange Flash economics with a great entryprice and overall TCO. Unity All Flash configurations start under $15K and Unityhybrid configurations start under $10K. UnityVSA allows anyone to get started forfree and upgrade into the supported virtual edition, a purpose-built hybrid or all-Flash system, or into converged infrastructure.
l Flexible: You can meet any storage deployment requirement with Unity fromvirtual to purpose-built to converged infrastructure. All deployment optionssupport the same data unified data services (SAN/NAS and VVols) to support anyworkload with traditional file (file consolidation, VDI user data, home directories)as well as transactional workloads for both file and block on both all Flash andhybrid configurations (Oracle, Exchange, SQL Server, SharePoint, SAP, VMwareand Microsoft Hyper-V).
New and enhanced featuresThe following features have been added or enhanced for this release.
Security Administrator RoleThe role of Security Administrator has been added to the existing roles available in thesystem. This role has full privileges for security operations but only operator privilegesfor storage operations. It provides security best practices of separating duties toensure that as few people as possible with administrator privileges have full access tothe system.
Release Notes
New and enhanced features 3
Security Hardening/STIG compliance (physical deployments only)New processes have been added to harden a Unity system in order to comply with theDISA STIG standards. A new service command, svc_stig [qualifiers], wasadded to provide the ability to enable or disable STIG mode on a system. You can alsoascertain the status of the STIG mode on the array using this script. All three options,enable, disable, and status can be profiled based on the STIG categories I and II. Thestorage system will persist the STIG mode and preserve it through software upgrade.
In addition, a user with an administrator or security administrator role now has thecapability to enable, disable, view, and configure settings related to user accountsthrough a new UEMCLI command:
/user/account/settings set [-enabled { yes | no }] [-passwdMinSize <value>] [-passwdCount <value>] [-passwdPeriod <value>] [-maxFailedLogins <value>] [-failedLoginPeriod <value>] [-lockoutPeriod <value>] [-sessionIdleTimeout <value>] [-defaultAdminLockoutEnabled { yes | no }]
Also, a new output field was added to the /user/account show -detail UEMCLIcommand to support the ability to view the password expiration status for a useraccount.
Dynamic pool enhancementsThe pool properties page now displays the RAID type and width for a dynamic pool. Ifthere are multiple drive types in the pool, such as SAS Flash 3 and SAS Flash 4 drives,the RAID type and width for each drive type is displayed.
In addition, Unisphere provides clearer messaging in the following situations:
l When you expand a dynamic pool using drives less than the RAID width, Unispheredisplays an informational message indicating that the expansion process might betime consuming.
l When you create or expand a pool associated with larger capacity drives, if theentire drive capacity will not be usable Unisphere recommends the number andtypes of drives to add in order to utilize the entire capacity
Support for SNMP v2Unity's existing SNMP v3 trap notification support has been extended to also coverSNMP v2c. A Maximum of 10 SNMP trap destinations is supported.
Online data-in-place conversionsData-in-place (DIP) conversions allow for the orderly upgrade a system storageprocessors from lower-end modules to a higher-end models, while preserving existingdata and configurations. As of this release, this process can be performed while thesystem is online, keeping all data available during the upgrade.
For specific information about supported systems for Unity online data-in-placeupgrades, refer to the Unity Data in Place Conversion Guide, available on EMC.comand support.emc.com.
Fail-safe NetworkingThe Fail-Safe Network (FSN) feature provides network high-availability that extendslink failover into the network by providing switch-level redundancy. An FSN can be aport, a link aggregation, or any combination of the two. An FSN adds an extra layer ofavailability to link aggregations alone. Link aggregations provide availability in theevent of a port failure; FSNs provide availability in the event of a switch failure. If thenetwork switch for the active connection fails, the FSN fails over to a connectionusing a different switch, thus extending link failover out into the network.
Release Notes
4 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Base LUN refresh from any snapshot versionAdded support for promoting test thin clones to production by refreshing the basestorage resource with a snapshot from the base resource's family. This provides theability to refresh production environments based on factors such as performancetuning, query optimization, and bug fixes.
Updated UnityVSA RequirementsUnity 4.2.1.9535982 is the last release where UnityVSA is supported to run on olderCPUs (those that do not support SSE4.2 or greater). If you have an existing UnityVSAdeployment with CPU that does not support SSE4.2 (or greater), you can upgradeUnityVSA in the following ways:
l Deploy a new UnityVSA on another server with a CPU that supports SSE4.2 (orgreater).
l Bring the your current UnityVSA server offline and migrate it to another newserver.
Unity File Storage Resource Adapter (SRA) supportUnity File SRA supports only VMware datastore types in Unisphere. For eachProtection Group or Recovery Plan, you must create a separate NAS server withassociated VMware datastores under it. Generic NFS datastores are not supported inUnisphere. Refer to the latest Unity File Storage Replication Adapter (SRA) ReleaseNotes for more information.
Fixed issuesFixed issues in this release.
Unity fFamily systems fixed issues
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
888936 When deleting a host-configuration,Unisphere did not make it clear that hostresources need to be disconnected beforethe host configuration could be deleted.
Unisphere messaging explainsthat before deleting a host-configuration you must removeaccess to the hostconfiguration.
4.2.1.9535982
899530 When enabling secure NFS through theUnity NAS Server creation wizard, thenecessary (Kerberos) keytab files were notuploaded.
After the NAS server iscreated, upload the keytab filesfrom the Unisphere NASServer page (or using the UnityUEMCLI or REST API).
4.2.0.9200824 4.2.1.9535982
890307 When running the MluCli startfsrecoveryrequired command, if the user entered alower deck file system ID where the MluClicommand expected a UFS64 ID, the lowerdeck file system would go offline.
Fixed in code. 4.0.1.8404134 4.2.1.9535982
891311 AIX hosts could not boot when their bootLUN is on Unity system.
Fixed in code. 4.1.0.9058043 4.2.1.9535982
892354 When disabling FAST Cache on a poolexposed to heavy I/O, FAST Cache was
Fixed in code. 4.2.0.9101276 4.2.1.9535982
Release Notes
Unity File Storage Resource Adapter (SRA) support 5
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
disabled but Unity indicated it was stillenabled on the pool.
892953 When a Flash drive went into a faulted state,instead of displaying the drive's fault stateand recommending to remove the drive,Unisphere returned an Unexpected errorwith error code 0x7d13001.
Fixed in code. 4.2.0.9180216 4.2.1.9535982
894964 When using NAS Server replication,destination system sometimes inaccuratelyreported that DNS, NIS or LDAP serviceswere not accessible.
Destination replication systemsdo not report access issueswith DNS/NIS/LDAP.
4.0.1.8404134 4.2.1.9535982
895860 Illegal Fiber Channel commands received byUnity storage processor (SP) sometimescaused unexpected reboots.
Fixed in code. 4.1.0.9058043 4.2.1.9535982
897452 Unity pools reported significantly moreconsumed space than was actuallyconsumed.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
897656 In some Unity CIFS configurations, quotausage figures did not change even when fileswere duplicated/copied or deleted.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
902846 When an invalid route 0.0.0.0 wasconfigured on a NAS Server, the systemincorrectly alerted that the NAS Server fileinterface was offline.
Fixed so that invalid routeconfigurations are not allowed.
4.1.1.9138882 4.2.1.9535982
904084 When a Unity IO module commit failed dueto a hardware configuration issue, Unityreturned the following message:Commitfailed Error code: 0x9000002Cannot commit the configurationbecause it is invalid.
Unity preforms a hardwaresetup check to provide moredetailed information about theI/O module commit status.
4.1.1.9138882 4.2.1.9535982
904644 In Unisphere, when the number of Unitytraditional spares became depleted, no inlineinformation indicated that the Hot SpareAvailable count was negative.
Fixed in code. 4.2.0.9174228 4.2.1.9535982
904927 When performing snapshot restoreoperations, occasionally a primary LUNwould fail, and the snapshot operation onthat resource was interrupted.
Fixed in code. 4.2.0.9228083 4.2.1.9535982
905147/910214
When network environment issues occurred,asynchronous replication sessions or NDMPbackup operations could hang.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
905179 After disabling the Unisphere Virus Checkerfeature, Unisphere did not immediately showthe setting was disabled.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
905341 During Unity OE software upgrades or onlinehardware upgrades, active asynchronous
Fixed in code. 4.2.0.9293280 4.2.1.9535982
Release Notes
6 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
replication sessions were interrupted untilthe upgrade completed with the warningcondition: Lost Communication. The
sessions were restored after the upgradeprocess completed.
905988 If a Fibre Channel connection used forsynchronous replication was interruptedbecause of a network issue whilesynchronization between the source anddestination was active, the replicationsession connection would not recoverautomatically. Unity generated a LostSync Communication warningmessage.
Fixed in code. 4.2.0.9313057 4.2.1.9535982
906281 Under stressful conditions, modifying a viruschecking configuration (or disabling thefeature), could take a long time to complete.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
907120 When many clients accessed a Unity NASserver on which IP-reflect was enabled, aUnity storage processor reboot could occurand interrupt SMB/CIFS data I/O to theserver.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
907282 A deadlock occurred in a file system and theassociated NAS server appeared to hang.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
908352 NDMP backup sessions hang because ofissues with the scheduling algorithm withinthe transport transmit code .
Fixed in code. 4.1.1.9138882 4.2.1.9535982
908967 When a replication destination systemrebooted during a replication switchoverprocess, Unity temporarily displayed thereplication destination file system size as 0.
Fixed in code. 4.2.0.9333652 4.2.1.9535982
908768/929343
Under particular conditions users cannotaccess files or directories associated withACL IDs that have bad reference counts.Symptoms can include:
l Clicking on an affected file/directory, anerror message indicates that there is aninternal error and the file is notaccessible.
l Attempting configure ACL data byclicking File > Properties > Security,displayed message text indicates thatthe requested security information iseither unavailable or can't be displayed.
l Attempting to configure ACL data usingthe Windows icacls.exe command line
Fixed in code. 4.1.2.9257522 4.2.1.9535982
Release Notes
Fixed issues 7
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
tool, returns a message indicates that aninternal error occurred.
909769 After a destination replication file systemwent offline, the file system recovery failed.
Fixed in code. 4.1.2.9257522 4.2.1.9535982
909842 When migrating data from a VNX (source)system to a Unity (destination) system, theprocess did not complete if a NAS Servername on the Unity system matched a VDMname on the VNX system.
Fixed in code. 4.2.1.9346469 4.2.1.9535982
910034 During an NDMP restore operation, a UnityStorage Processor reboot could occur if arestore file or directory had a SecurityDescriptor (SD) with an empty DiscretionaryACL (DACL).
Fixed in code. 4.1.2.9257522 4.2.1.9535982
910192 When a Unity file system configured within aquota was close to full, it would occasionallygo offline and the file system recovery wouldbe blocked because the quota check processthought that there was no remaining spaceon the file system.
Fixed in code. 4.2.0.9322169 4.2.1.9535982
910856 During migration, files and directories onsource systems that did not contain SecurityDescriptors (SDs) or Discretionary AccessControl Lists (DACLs) were migrated withempty DACLs rather than no SDs. Thisprevented access to files and directories onthe destination system.
Fixed in code. 4.2.0.9357089 4.2.1.9535982
911070 During asynchronous replication, after asnapshot was replicated from a sourcesystem to destination system, the snapshotcould not be deleted on the destinationsystem.
Fixed in code. 4.2.0.9357089 4.2.1.9535982
911139 Under certain conditions, because ofimproper setup of network sockets, the TCPreceived window auto-tuning was disabled.This resulted in reduced networkthroughput.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
911219 When the Unity Virus Checker feature wasset to Scan On Read, occasionally filecreation failed while returning a NameCollision error.
Fixed in code. 4.2.1.9535982
911390 When viewing file systems with Unisphere,the Quota tab did not appear.
Fixed in code. 4.2.1.9535982
911502 If a Unity system experienced heavy I/Oduring a snapshot restore operation, thesnapshot restore operation could fail. Under
Fixed in code. 4.2.0.9361957 4.2.1.9535982
Release Notes
8 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
some circumstances, users could notperform any other snapshot operations untilinterrupting the I/O through the system andresetting the snapshot restore operation.
911592 The Unisphere Advanced SMB Propertiestab indicated that UMASK is onlyused when the access policyis Unix, even though Unity supports
UMASK for both Unix or Native accesspolicies.
Updated text on UnisphereAdvanced SMB Properties tab(online hep will be revised innext release).
4.2.0.9368748 4.2.1.9535982
911959 Under some circumstances, Unityasynchronous replication operations wereinterrupted because of a network issue andthe system failed to update the replicationlast sync time.
Fixed in code. 4.2.0.9371476 4.2.1.9535982
911997 If a NAS server was in a faulted state whenthe Unisphere management services started,SMB and NFS share information for the NASserver would unavailable through Unisphereand the UEMCLI.
Fixed in code. 4.2.0.9368748 4.2.1.9535982
912021 If I/O reached media error on a disk in adynamic pool and the I/O goes through zeroon demand path, a Unity single storageprocessor reboot could occur while mappedRAID handled the media error reported bythe disk.
Fixed in code. 4.2.0.9377468 4.2.1.9535982
912115 When using Unisphere to configure an NFSNAS Server with multiprotocol enabled,
enabling or disabling the Secure NFS(with Kerberos) option generated an errorand lost the associated NAS server settingchanges.
Fixed in code. 4.2.0.9368748 4.2.1.9535982
912419 Using the UEMCLI to query complexhistorical metrics in large configurationscould exceed the system's memorycapability, leading to a Storage Processorreboot and interrupting access to Unisphere.
Fixed in code. 4.2.0.9361957 4.2.1.9535982
912583 When uploading a Unity upgrade imagelarger than 2GB, the system sometimesexperienced a Storage Processor reboot,because there was not enough space on theStorage Processor for the image.
Fixed in code. 4.2.0.9368748 4.2.1.9535982
912590 When using Unisphere to expand a dynamicpool, the available drive count for expandingthe pool showed as "0", even though driveswere available for the expansion.
Fixed in code. 4.2.1.9381621 4.2.1.9535982
Release Notes
Fixed issues 9
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
912730 When a storage processor (SP)rebooted ona Unity system used as a replicationdestination, the replication session could notbe managed through Unisphere and (fromreplication source side) the session appearedto be in a non-recoverable error condition.
The time out duration for areplication session loadingduring an SP reboot wasincreased to allow replicationsessions to load properly.
4.2.0.9361957 4.2.1.9535982
912885 Running SFTP while using a Linux Java SSHclient can cause an unexpected storageprocessor reboot.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
913250 When snapshot replication was enabled,Unity replication sessions entered an errorstate when replication synchronizationbegan. This occurred whether the processwas initiated manually or as part of ascheduled process.
Fixed in code. 4.2.0.9388690 4.2.1.9535982
913316 When viewing performance metrics withUnisphere, high CPU utilization could lead togaps in the displayed performanceinformation.
Fixed in code. 4.2.0.9289601 4.2.1.9535982
913802 Storage processor rebooted due to intercommunication issue between storageprocessors.
Fixed in code. 4.1.2.9257522 4.2.1.9535982
913890 During the Unity initial configuration
process, clicking on Next before thelicensing process completed would result inPools and Fast Cache appearing asunlicensed features.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
914537 When performing a snapshot diff using theREST API, occasionally a failure would occurif a consistency group contained different-sized LUNs and the first LUN was not thelargest.
Fixed in code. 4.2.0.9382708 4.2.1.9535982
914565 A high concentration of messages (forexample, I/O errors) from NAS servers orfile systems could interrupt Unity storagepool operation, and cause the pools to reset.After the storage pools recovered, the NASservers and file systems would remainoffline.
Fixed in code. 4.2.1.9391129 4.2.1.9535982
914755 NAS file systems occasionally went offlinewhen users attempted to write I/O to thefile system after an auto-extend operationoccurred.
Fixed in code. 4.1.2.9257522 4.2.1.9535982
915354 When using REST API commands to changesensitive parameters (for example,passwords), querying the request displayed
Fixed in code. 4.1.1.9138882 4.2.1.9535982
Release Notes
10 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
the sensitive information in plain text in thequery response.
915504 A Unity storage processor reboot occurredwhen the code attempted to read or write abad block.
Unity returns an error insteadof performing a reboot.
4.1.1.9138882 4.2.1.9535982
916228 The number of hosts defined for NFSexports was limited to approximately 20,when it should have allowed up to 256entries.
Fixed in code. 4.2.1.9535982 4.2.1.9535982
916389 Under particular conditions, the Unity OEupgrade failed and one Storage Processorremained in Service mode.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
916420/919978/912393
Under particular conditions, if heavy I/Ooccurred during a Unity OE upgrade, thiscaused LUNs to go offline.
Fixed in code. 4.2.1.9391129 4.2.1.95359
916879 When a Unity NAS server or file systemwent offline, this caused a temporary Unitystorage pool problem. After the storage poolissue was resolved, sometimes the NASserver and file system remained offline.
Fixed in code. 4.2.1.9391129 4.2.1.9535982
917068 During a file server or NAS server replicationrefresh operations, occasionally thedestination NAS server briefly becameunmounted and an unexpected storageprocessor reboot would occur.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
917271 A Unity Storage Processor could go intoservice mode if the reverse passwordencoding set in local file for CEPP waslonger than 15 characters.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
917983 An unexpected Unity storage processor (SP)reboot occurred because of a race betweenmultiple threads to write to same area.
Fixed in code. 4.1.2.9257522 4.2.1.9535982
918221 CIFS migration occasionally caused amemory leak during the access control list(ACL) preservation process that would leadto unexpected storage processor reboots.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
918298 CIFS clients experienced I/O errors and lostaccess to certain files when there wasconcurrent access to files with alternatedata streams.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
919039 Unexpected storage processor rebootsoccurred when both LDAP serversassociated with a Unity NAS server wentoffline.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
Release Notes
Fixed issues 11
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
919468/916340
When a Unity system was subject to heavyI/O traffic during a Unity OS upgradeprocess, then LUNs could go offline.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
919474 When attempting to uninstall root accessusing with the Unity Service commandsvc_inject, the following error appeared :ERROR [spa]: Uninstallation ofOEM pack is not allowed
Fixed in code. 4.2.0.9392909 4.2.1.9535982
920028 When using NFSV4.0, if the NAS server wasnot correctly configured to access NFS V4hosts with delegation callback pathverification, delays could occur in failoverand failback operations. Log messages wouldindicate that the delegation path was invalidand that the callback path could not beverified.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
920740 When configuring or unmounting a filesystem on Unity, occasionally unexpectedstorage processor reboot would occur andthe file system would be temporarilyinaccessible.
Fixed in code. 4.2.0.9392909 4.2.1.9535982
923256 Installing Unity OE 4.2 software caused highStorage Processor CPU utilization and I/Olatencies after snapshot deletions. Thiscould last for an extended period until spacewas reclaimed from the LUN or File Systemto the storage pool
Fixed in code. 4.2.0.9433914 4.2.1.9535982
923258/928363
Using the service commandsvc_purge_logs --clear --force on
a Unity storage processor (SP) incorrectlyremoved a local metadata file whichtriggered a rolling storage processor reboot.
Fixed in code. 4.0.0.7329627and later
4.2.1.9535982
925134/927564
After using a VVol Datastore to create avirtual machine (VM), if you created a baseVVol, bound a base VVol, created a VVolSnap, or bound a VVol snap, then the VMcould not be removed.
Fixed in code. 4.2.0.9433914 4.2.1.9535982
925175 Incorrect version handling in the replicationdatabase caused a Unity storage processorreboot when upgrading from earlier softwarerevisions to 4.2.0.9476662.
Fixed in code. 4.1.2.9257522 4.2.1.9535982
926964 When using Unisphere to delete a filesystem, the deletion process hangs and thefile systems persist.
Fixed in code. 4.1.1.9138882 4.2.1.9535982
926984 Toshiba PM3/PM4 or Samsung REXa drivesfailed with hardware errors.
Fixed in code. 4.1.2.9257522 4.2.1.9535982
Release Notes
12 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
927473 When an LACP bond was used for Qlogicdevices, onboard CNA and Maelstrom SLICport I/O could become interrupted, requiringan Ethernet device reset or storageprocessor reboot to resolve the issue.
Fixed in code. 4.2.0.9357089 4.2.1.9535982
927511 A combination of high Unity metrics usageand high NAS file system activity causedUnity storage processor reboots.
Fixed in code. 4.2.0.9433914 4.2.1.9535982
927564 Customers running VVols on Unity systemswith OE version 4.0.x/4.1.x who upgradedthe Unity OS (to 4.2.0.9392909,4.2.0.9433914, 4.2.0.9476662) experiencedstorage access problems if they hadunbound a (previously bound) VVol withbound snaps, or if there they still had a VVolsnap that was not unbound.
Fixed in code. 4.2.0.9433914 4.2.1.9535982
927617/928135
Improper error handling when a NAS serverfailed to ping its DNS or NIS Servertriggered a Unity storage processor reboot.
Fixed in code. 4.0.0.7329627and later.
4.2.1.9535982
928707 Migrating data from VNX systems to toUnity systems failed when the source filesystem contained files or directories withthe names ending with "." (dot) or "" (space)."
Unity now supports file/directory CIFS names withtrailing dots or spaces. IfReplication is used in theseenvironments, both source anddestination systems must beupgraded to 4.2.x to ensurecorrect operation.
4.2.0.9433914 4.2.1.9535982
929139 Replication system snapshot refreshoperations would fail because the snapshotfile creation process failed in CBFS.
Fixed in code. 4.2.1.9505708 4.2.1.9535982
929507 Unity storage processors SPA and SPBconcurrently rebooted and Toshiba drivesreported errors.
Fixed in code. 4.2.0.9433914 4.2.1.9535982
929521 On Unity systems with large amounts ofallocated storage (greater than 500 TB),multiple storage processor reboots couldoccur when manual or scheduled re-balancing was initiated.
Fixed in code. 4.2.0.9433914 4.2.1.9535982
930652 After installing the initial license on a newUnity system, occasionally specific featuresdid not appear to be enabled in Unisphere,even then they had been configured usingthe Initial Configuration Wizard.
Fixed in code. 4.2.1.9528967 4.2.1.9535982
930868 When using Unisphere to delete snapshots,the deletion jobs included both usersnapshots and system snapshots. The user
Fixed in code. 4.2.1.9528967 4.2.1.9535982
Release Notes
Fixed issues 13
Issuenumber
Problem summary Description of fix Exists inversion
Fixed inversion
snapshots were deleted, but the systemsnapshots were not.
930937 When configuring the Unity Density BasedLimit setting, the following issues sometimesoccurred:
l If LUN size was an even number of TB(for example, 2TB, 4TB, or 8 TB), thehost IO limit did not take effect resultingin a 0x9009ffe error message.
l If the LUN size was greater than 2TBand an odd number of TB, the host IOlimit change was accepted, but theapplied IO limit was less then requested.
Fixed in code. 4.2.1.9528967 4.2.1.9535982
931006 If you try to use the UEMCLI to add one ormore ESXi host object addresses to theignore list (using the -ignoredAddrparameter), Unity returns and errormessage.
Fixed in code. 4.2.1.9535982
931100 Memory leaks occurred in the FAST VPpolicy engine service, eventually causing thestorage processor to run out of memory andreboot.
Fixed in code. 4.2.1.9505708 4.2.1.9535982
Fixed in previous releasesLearn about fixed issues in Unity.
Issue number Problem summary Description of fix Found inversion
Fixed inversion
918298 Under particular conditions CIFSclients may experience I/O errorsand loss of access to certain filesafter an OE upgrade.
Fixed in code. 4.2.0.9392909 4.2.0.9476662
923256 Installing Unity OE 4.2 softwarecaused high Storage Processor CPUutilization and IO latencies aftersnapshot deletions. Under certainconditions, this could last for anextended period while space wasreclaimed from the LUN or FileSystem to the storage pool.
Fixed in code. 4.2.0.9392909 4.2.0.9476662
916340 Under particular conditions, if IOoccurred during a Unity OE upgrade,this caused LUNs to go offline.
Fixed in code. 4.2.0.9392909 4.2.0.9476662
916389 Under particular conditions, theUnity OE upgrade failed and one
Fixed in code. 4.2.0.9392909 4.2.0.9476662
Release Notes
14 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
Storage Processor remained inService mode.
896300 In Unisphere, deleting multiplereplication sessions at same time cancause the Storage Processor toreboot.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
895276 Under particular conditions, userscannot assign RecoverPoint hostaccess to a LUN/CG usingUnisphere. When a remote thatLUN/CG is involved in aasynchronous replication processhas same friendly ID as a localLUN/CG (that is not part of thereplication process), Unisphere doesnot allow RecoverPoint host accessto the local LUN/CG .
Fixed in code. All previousversions.
4.2.0.9392909
871149/ 887563 Under certain circumstances in apool full condition, a shared folder inthat pool could go offline. As thepool approaches full, shared folderswill move to a read-only mode andmove back to read/write mode oncethe pool full condition is cleared.This happens when thepoolFullPolicy is
failWrites. File system snap
objects may also go offline in thepool full condition when thepoolFullPolicy is
deleteAllSnaps. When the file
system or snap goes offline, it doesnot automatically go back onlineonce the pool full condition iscleared.
Fixed in code. 4.1.0.8940590and later
4.2.0.9392909
879477 Upon starting a migration session,the storage processor rebooted. Themigration health was in a failed stateand migration could not recoverautomatically.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
05748033/882346
When a primary storage processorentered service mode, the real-timeperformance charts in Unispheredisplayed the following errormessage: Unknown internalmetrics error hasoccurred(0x7d14013).
When a secondary storageprocessor entered service mode, the
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
Release Notes
Fixed in previous releases 15
Issue number Problem summary Description of fix Found inversion
Fixed inversion
real-time performance charts inUnisphere displayed the followingerror message: Query ID notfound (0x7d1400c).
After logging out of Unisphere andthen logging back in, the real-timeperformance charts displayed thefollowing error message: Unknowninternal metrics errorhas occurred(0x7d14013).
883270 When using the CLI for an importsession, the imported destinationLUN resource was created with aname that did not match the sourceLUN resource.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
875348 When viewing the System >
Service > Overview page in
Unisphere, the SupportCredentials and EMC SecureRemote Services sections did notrefresh after the Initial ConfigurationWizard was relaunched and thesupport credentials were modified.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
875394 A create replication operation failedwith the following error code:0x9881. This was due to duplicate
internal requests issued from theprimary array.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
877646 / 871640 An error was returned during anattempt to enable Secure NFS. Thishappened when local files wereenabled as Unix Directory Services.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
879943 The Compress Now option in theConsistency Group Member LUNstable is sometimes disabled when itshould be enabled.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
881402 When share was created from a NASServer whose SP is different fromthe management SP, the systemreturns an operation due to atimeout.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
888423 When upgrading from a Unity 4.0 toa Unity 4.1 software version:
l If an asynchronous remoteconnection exists prior to theupgrade, the upgrade will be
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
Release Notes
16 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
successful, but the remoteconnection may not be updated.
l If a synchronous remoteconnection exists prior to theupgrade, the upgrade will besuccessful, but the synchronousFC port information may nolonger be visible for the remoteconnection through Unisphereor the CLI.
871640 When using local files as UnixDirectory Service (UDS), amultiprotocol NAS server cannot beconfigured using the Unisphere UI:
l NIS/LDAP cannot be disabledon an existing multiprotocol NASserver with UDS.
l A new multiprotocol NAS serverusing UDS cannot be created.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
865863 When creating new LUNs in the
Create a Consistency Groupwizard, creation of LUNs smallerthan 1.0 GB were allowed on the
Configure LUNs dialog.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
872071 In System > System View >
Enclosures, the ReplicationCapability displayed for an FCmanagement port indicates that this
port can be used for SyncReplication management.Management ports cannot be usedfor I/O.
Fixed in code. All versions. 4.2.0.9392909
871647 After the port commit processfinishes successfully, there is apossibility that only the alerts forports on current primary SP will begenerated.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
862827 After failover from one storageprocessor to another, themanagement interface entries aredisplayed as duplicated in UnisphereCLI and REST API for severalminutes.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
866518 Cancelling a migration fails withunexpected error Operationfailed. Error code:0x6000003 The system
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
Release Notes
Fixed in previous releases 17
Issue number Problem summary Description of fix Found inversion
Fixed inversion
encountered an unexpectederror. Try again and ifthat attempt fails thensearch for the error codeon the support website orproduct forums, or contactyour service provider, ifavailable. (Error Code:0x6000003). Retrying the
cancellation also fails with sameerror message.
857825/ 862480 For a job status of Completedwith problems, the Completedwith problems link does not workand will not go to the detailed errormessage.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
860824 When the route type is changed
from default to net or host, theroute disappears. The systemerroneously deletes the route ratherthan changing the configuration.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
863762 After upgrading from Unity 4.0.x to
4.1.x, the Configure button forlegacy historical metrics chart doesnot work.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
863871 When running Unisphere withChrome on a Windows 10 with TouchOS system, the widgets on thedashboard screen cannot be moved.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
864228 After a Data-in-place Conversion,the time on one or both SPs was notset correctly, even with an NTPserver configured.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
852455 /81596330
When the primary file system hadquotas enabled and a read-only snapwas created, the show command to
view files belonging to a quota on aread-only snap failed.
Fixed in code. 4.0.0.7329527and later.
4.2.0.9392909
865403 /82485742
Using C$, access to .etc directorywas rejected, even if the user rolewas administrator. File extensionfiltering behavior could not beconfigured.
Fixed in code. 4.0.0.7329527and later.
4.2.0.9392909
866566 / 5241101 Aborting an UFS64 recovery failedwith an invalid processhandle error.
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
Release Notes
18 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
868396 / 5168225 After failback, some file systemswere no longer accessible. The filesystems could not be remounted andfollowing error was in the ktrace:sade:CBFS: 3:[core] mountfs fails for fsid536870964, File_StatusBusy . The issue occurred when C$
was used at time of the failover, withaccess to the FS which could not beremounted.
Fixed in code. 4.0.1.8194551and later.
4.2.0.9392909
871679 / 5209943 Common Anti Virus Agent (CAVA)cannot be restarted by theMicrosoft Management Console(MMC) after it had beenautomatically stopped (per policy)when all virus checkers went offline.
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
871696 / 5378990 The mode bits generated on file/dircreation were unexpectedly set to777 when the owner was a Group(for example, Domain Admins).
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
872109 / 5252987 An unexpected NFSv4 session erroroccurred on the client side when thesame client was working with twodifferent NAS server on the sameSP. It was highly visible on the ESXhost when an ESX server wasworking on two NAS servers locatedon two SPs, but once a failoveroccurred, the ESX host seemed tohave lost access to the NAS servers.
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
879133 /82489490
When using RVSS to createsnapshots on a share from theMicrosoft Windows API, sharenames greater than 80 characterscould not be displayed in the MMC.
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
881080 /83467828
A single SP panic occurred duringLUN migration.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
881386 / 5378990 When using EMCopy to transferfiles, files owned by Unix SID owner/group had the group owner changedto "nobody".
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
883644 / 5784193 In a rare cases when creating areplication session with a LUN that isin the process of being deleted, thestorage system failed andtransitioned to a rolling SP rebootloop.
Fixed in code. 4.0.2.8627717and later.
4.2.0.9392909
Release Notes
Fixed in previous releases 19
Issue number Problem summary Description of fix Found inversion
Fixed inversion
883730 /83860616
VMware hosts appeared inUnisphere with a warning sign due toduplicate IP used for vShield169.254.1.1 (or other products whichcreated identical internal IPaddresses on different ESXi hostswithin a cluster).
The false positive healthdegradation was fixed for suchESXi hosts.
4.1.0.8959731and later.
4.2.0.9392909
884076 /84114380
When a non-disruptive upgrade(NDU) occurred, performancearchive files may have been createdas empty files without any metricdata every hour. This happenedwhen the metrics collector lostconnection with the metricsproducer and that connection couldnot be reconnected successfully.Refer to KB article 000496872 formore details.
Fixed in code. 4.1.0.8959731and later.
4.2.0.9392909
885028 / 5286633886045 / 6197446
UFS64 recovery failed on an UFS64with a specific DUCH corruptionissues.
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
885281 / 6085603 Integrated ESRS could not beconfigured successfully in a proxy-only environment.
Fixed in code. 4.1.0.9058043and later.
4.2.0.9392909
885499 / 5748033 The Real-time metrics chart on theUnisphere Performance Dashboardpage could not be created when oneof SPs was in service mode.
Fixed in code. 4.1.0.8770695and later.
4.2.0.9392909
888429 /84555868
A Compress Now cancellationoperation on a LUN stoppedprogressing at the 50% completemark.
Fixed in code. 4.1.0.9058043and later.
4.2.0.9392909
888467 /83742634
A NAS server got stuck failing backto its parent SP when the parent SPcame online after a failure. Thisoccurred when the CIFS clients withopen files and oplocks didn't respondto the oplock break request from theNAS Server during shutdown.
Fixed in code. 4.1.0.8959731and later.
4.2.0.9392909
889347 / 6383016 A LUN was inaccessible, eventhough it appeared online.
Fixed in code. 4.1.0.8959731and later.
4.2.0.9392909
889744 / 6222835 Fast cache creation was incorrectlydisabled when no spare drives wereavailable.
Fixed in code. 4.1.0.8959731and later.
4.2.0.9392909
889944 / 5920468 A Windows user with user quotasconfigured saw the full file system
Fixed in code. 4.1.0.8959731and later.
4.2.0.9392909
Release Notes
20 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
size instead of the specific userquota hard limit size.
890499 /84630172
An Excel file could not be savedusing Mac Operating System ElCapitan with MS Office for Apple.An error was returned.
Fixed in code. 4.1.0.9058043and later.
4.2.0.9392909
890658 /84114380
If an archive file was createdsuccessfully by using metrics_clitool, sometimes system did not closethe socket, which resulted in amemory leak in the system. Theobservability-collector restartedafter a few days.
The observability-collector hasbeen fixed to make sure thesocket is closed beforedestroying the thread.
4.1.0.8959731and later.
4.2.0.9392909
891401 / 6489073 Lower system performance wasseen during a LUN migration.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
892794/ 6548072 When the Support Credentialspassword contained some specialcharacters, the validation sometimesfailed. Refer to KB article000496776 for more information.
The code has been undated tohandle special characters.
4.0.1.8320161and later.
4.2.0.9392909
893547 /85020034
When a file system was running outof space, it requested adding slicesfrom a pool LUN. This request couldbe denied for reasons such as thepool being full. If the initial requestedslice was a data slice, but a shadowslice was needed to cover that dataslice, the thread was blocked by thedata slice request condition.
Fixed in code. 4.0.0.7329527and later.
4.2.0.9392909
894314 / 6297038 In certain cases, with Windows 7,get FileProperties from explorer hada 10 second delay.
Fixed in code. 4.0.2.8627717and later.
4.2.0.9392909
894559 An 0x100000a error occurred if
there was any special unicodecharacter in a UEMCLI inputcommand.
The code has been updated tosupport special unicodecharacters for CLI.
4.1.0.9058043and later.
4.2.0.9392909
887115 / 895104 /6141059
An SP rebooted due to memoryissue. A 552 byte memory leakoccurred when due to a SCSI-3persistent reservation SCSIcommand. This leak occurs when theinternal database is being updated tokeep the two SPs in sync withrespect to persistent reservations.
Fixed in code. All previousversions.
4.2.0.9392909
896169 When the verification of a remotesystem fails, a 100b (task not
started) error code was displayed.
Fixed in code. 4.1.2.9257522and later.
4.2.0.9392909
Release Notes
Fixed in previous releases 21
Issue number Problem summary Description of fix Found inversion
Fixed inversion
896942 /85342914
After a successful file systemrecovery, accessing a certaindirectory in the file system caused apanic.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
897239 / 6674487 The NFS migration commitmentstalled after system reboot.
Fixed in code. 4.1.0.9058043and later.
4.2.0.9392909
899304 / 6845371 An EMCopy or NDMP movement ofDHSM stub files from VNX to Unitythat uses HTTP connections willresult in unreadable stub files on thetarget Unity NAS file system. If thecopy operation pulls data rather thanattempts to preserve the stub files,there is no issue with this operation.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
899770 /85672764
A single SP panic occurred duringLUN migration.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
899860 / 6954348 After a successful file systemrecovery, opening a directory in thefile system will cause file system togo offline again.
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
900642 /84251316909437 /07504276
The system panics. Fixed in code. 4.1.0.9058043and later.
4.2.0.9392909
901262 / 6536673 The CPU utilization does notdecrease significantly when systemis idle because of backgroundactivity on an All-flash pool.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
902578 /85569294
When drive in a pool reached end oflife and the Unity system completeda proactive copy, the drive wasreplaced with the spare and takenoffline. It could sometimes take upto 10 hours for an alert to be sent(with call home or ESRS).
The call home alert will be sentimmediately after the proactivecopy is completed and the diskis taken offline.
4.1.1.9138882and later.
4.2.0.9392909
902923 /85658194
When an operator user account wascreated in Unisphere, the user wasable to change tree quotas values.
The code has been fixed tocorrectly only users with theadministrator role to modifytree quotas.
4.1.1.9138882and later.
4.2.0.9392909
905575 / 7060779 In rare cases, if there were NDMPbackup jobs running while browseNDMP client or configure NDMPclient operations were also ongoingfrom DMA, at the stage of listing thefile systems of the client the NDMPclient on Unity could panic.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
Release Notes
22 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
905819 /85491292
In the Consistency Group properties
under the Access > Accessdetails, the hosts are displayed withtheir respective LUNs andassociated host LUNs. However, onthe LUN page under host access allthe host LUNs are shown as a samevalue, which is not consistent withthe above-mentioned host LUNs.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
906607 / 7340137 When creating a replication session,an error occurred during thesnapshot phase, preventingsuccessful creation of that session.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
906856 / 7302240 Intermittent access issue occurredfor SMB host access.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
908011 / 82219888 Several alerts displayed, incorrectlyindicating an Ethernet port SP IOmodule port or FC port fault.
Fixed in code. 4.0.1.8404134and later.
4.2.0.9392909
908705 If there was a replication sessionwhere the source was a Unity 4.1.1system, and the source file systemused a legacy exported file systemID (originally migrated from VNX),after replication session wascreated, the wrong file system IDwas configured on the destinationfile system. Then, after a replicationfailover, the wrong exported filesystem ID was exposed to client andcaused data to become available. Ifthe source file system had a UUIDexported file system ID, this issuedid not occur. If the replicationsession has not yet failed over, thewrong exported file system ID willnot be exposed to clients, eventhough it is configured on thedestination file system.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
909045 When using CAVA over multiple NASservers, there were noticeabledelays, especially during lowchecking activity period (problemwas not visible when many files haveto be checked).
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
817119 When the pool threshold was met,the VDM could not be created.
The issue has been fixed toallow VDM creation when thereis enough space on the pool.
4.1.1.91388824.1.0.90580434.1.0.89597314.1.0.8940590
4.2.0.9392909
Release Notes
Fixed in previous releases 23
Issue number Problem summary Description of fix Found inversion
Fixed inversion
851191 /883307 There is no Configure button forthe metrics charts generated using
the Top contributor dialog.
A Configure button in themetrics charts generated with a
Top contributor dialog is nowavailable. More objects can nowbe added by using this button.
All previousversions.
4.2.0.9392909
851877 Write performance to the share hadpoorer performance when protocolencryption was enabled.
CPU performance has beenimproved when accessing anencrypted share.
All previousversions.
4.2.0.9392909
864762 A panic occurred during a backuprestore operation.
Fixed in code. All previousversions.
4.2.0.9392909
866518 When a user tries to cancel amigration operation, it failed withunexpected error, code 0x6000003.Attempting to cancel again alsofailed with the same error message.
Fixed in code. 4.1.0.8959731and later.
4.2.0.9392909
860892 When importing from a VNX whereSTIG is configured, an SSHcommand will fail and cause theimport from VNX to Unity to fail.This is because STIG has a policywhich requires the user to changethe password regularly.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
866647 In Unisphere, the file system size
shown during the Create ImportSession wizard is different than thefile system size shown in
Properties for that file system.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
867076 CIFS shares were unaccessible. Theserver didn't respond to any servercommands and reports Input/output error.
Fixed in code. All previousversions.
4.2.0.9392909
867616 When cancelling a NDMP backupprocess from NDMP DMAapplication, the operation hung withthe status Cancel in Progresson the NDMP DMA application.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
867919 The cpu.uptime metric was
missing from the archive file.
Fixed in code. All previousversions.
4.2.0.9392909
867920 In the Create Pool wizard SelectAmount of Storage step, if drivesare selected which include systemdrives, the warning message (Thisselection includes thesystem drives. Please referto the Best Practices Guideon the Unity Support pagefor details about using
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
Release Notes
24 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
them.) will display under the drive
selection combination box. Afterchanging the selection to not includeany system drives, this warningmessage persists.
868072 If a file system deletion operationhappens during trespass time, theoperation may fail and the filesystem may go offline.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
868181 A VMware VVol datastore with acapability profile allocation morethan 16TB in size cannot be createdin Unisphere.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
868626 Unity indicates that a LUN migrationsession has stalled at 90% progressand will not allow you to cancel it,even though the session actuallycompleted successfully.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
869374 Historical data was missing in
Performance > PerformanceDashbord > Historical charts.
Fixed in code. 4.1.0.8940590and later
4.2.0.9392909
869465 The SP reboots due to NAS failurewith an error code of 0xFC0D6003due to slow failover of a systemVDM.
Fixed in code. The issueresolves itself after the SPreboot completes.
4.1.0.8940590and later.
4.2.0.9392909
870021 When the ls Unix command is
issued on a not-yet-migrateddirectory, a permission deniedor Input/output error might be
returned.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
870155 In the migration summary report,
Average data transfer speed(KB/sec) is incorrect. It should be
Average data transfer speed(MB/sec).
The correct speed units nowdisplay.
4.1.0.8940590and later.
4.2.0.9392909
870283 When doing a data-in-placeconversion and a problem exists onthe system, a general Internalerror message displays, rather
than a health check error or healthcheck warning.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
870868 When there are multiple remotesystem connections to VNXsystems, if one or more remotesystems loses connectivity to theVNX system, the Unity system willnot be able to connect to any of the
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
Release Notes
Fixed in previous releases 25
Issue number Problem summary Description of fix Found inversion
Fixed inversion
other VNX systems. This shows anon-recoverable error when importsessions are created on the healthy,connected remote systems.
871106 NFS 4.1 client loses access to theNFS exports if the client mounts filesystem from more than one NASserver running on the same SP. Thiscould also happen when one SPreboots and all the NAS servers onthat SP fail over to the secondarySP.
Fixed in code. The client is nowable to maintain more than oneNFSv4.1 session to multipleNAS servers on the same SP.
4.0.1.8404134and later.
4.2.0.9392909
871127 Access to multiple LUNs for a singlehost could not be modified at onetime. This had to be changed in theproperties for each LUN.
The Unisphere CLI now allowsmodification of host access formultiple LUN in a singlecommand. For example: /remote/host set -addLuns A,B,C -removeLuns X,Y,Z.
4.0.2.8627717and later.
4.2.0.9392909
871149 / 887563 Under certain circumstances in apool full condition, a shared folder inthat pool could go offline. As thepool approaches full, shared folderswill move to a read-only mode andmove back to read/write mode oncethe pool full condition is cleared.This happens when thepoolFullPolicy is
failWrites. File system snap
objects may also go offline in thepool full condition when thepoolFullPolicy is
deleteAllSnaps. When the file
system or snap goes offline, it doesnot automatically go back onlineonce the pool full condition iscleared.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
871620 The Unisphere CLI command /event/alert/hist show will
incorrectly show the alerts inascending order chronologically,displaying the oldest first. Whenthere are more than 100 alerts, onlythe oldest 100 alerts will be shown inthe Unisphere CLI output due to thedefault maximum limit.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
871647 After the port commit processfinishes successfully, there is apossibility that only the alerts for
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
Release Notes
26 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
ports on current primary SP will begenerated.
872071 / 792840 In System > System View >
Enclosures, the ReplicationCapability displayed for an FCmanagement port indicates that this
port can be used for SyncReplication management.Management ports cannot be usedfor I/O.
Fixed in code. All versions. 4.2.0.9392909
872287 / 885943 Some running LUN move sessionsstalled or stopped making progresswhen an Idle priority session was
created.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
879662 By default, a GPO in a Windowsdomain affects all users andcomputers that are contained in thelinked site, domain, or organizationalunit. The administrator can furtherspecify the computers that areaffected by a GPO by usingmembership in security groups in theAccess Control List (ACL) editor.According Microsoft, to apply a GPOto a specific group, the "ApplyGroup Policy" ACE is required. Bydefault, all Authenticated Users havethis permissions set to 'Allow'. Theissue is the GPO is applied to theCIFS server of the NAS server withany ACL. The ACL of the GPO is notchecked.
Fixed in code. If the CIFS serverof a NAS server does not belongto a security group of a GPOwith an 'Allow' permission of"Apply Group Policy", then theGPO is not applied to that CIFSserver. This is the Microsoftspecification.
All previousversions.
4.2.0.9392909
880620 /870763 / 874416
The Unisphere UI and CLI displayedall VMs from polled ESXi hosts, evenif those VMs were deployed on otherstorage systems.
Fixed in code. All previousversions.
4.2.0.9392909
882223 Unable to access NAS server overSFTP if LACP is configured
Code is fixed to allow access tothe NAS server over SFTP ifLACP is configured.
4.1.0.8940590and later.
4.2.0.9392909
884116 / 06047315 If three DNS server addresses wereentered into the text box under
Configure DNS server addressmanually, the Add button becamedisabled. Even if all the IP addressesin the text box were then selected
and deleted, the Add buttonremained disabled.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
Release Notes
Fixed in previous releases 27
Issue number Problem summary Description of fix Found inversion
Fixed inversion
888654 Changing the property of a SMBserver (for example, renaming it orchanging between stand alone anddomain server options), sometimescaused a file system reference leakwhen on a loaded system. Thisoccurred when there were openedfiles with durable handles waiting tobe reconnected at the time of theproperty change.
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
894894 Creating quota tree on a reused treeID will fail with an error messagesimilar to the following: Operationfailed. Error code:0x900021f Specified filesystem, tree path, user, orparameters are invalid.(Error Code:0x900021f)
Fixed in code. 4.1.1.9138882and later.
4.2.0.9392909
896169 When verification of the remotesystem fails, the following errormessage appeared: 100b errorcode (task not started).
Fixed in code. 4.1.2.9257522 4.2.0.9392909
897498 In replication configurations of twoor more source arrays to onedestination array, the name of thereplication source resource displayedin the replication session pages inthe Unisphere GUI may be incorrecton the destination. The names of theresources are correct on the sourcearrays. A similar name issue with thedestination resource names can beseen when there is one source arrayand two or more destination arrays.
Fixed in code. 4.1.2.9257522 4.2.0.9392909
899969 On the Unisphere dashboard,clicking the critical/error/warning
icons on the System Alerts widgetwould not navigate to the main
System Alerts page.
Fixed in code. 4.1.2.9257522 4.2.0.9392909
865060 When the storage system failed toconnect to EMC web services due toa timeout, the management servicewas interrupted for a while and anECOM dump would be generated.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
877937 When using svc_banner service
script to set the Unisphere loginbanner, if a Windows format file wasused, only the first line of the bannerwas shown.
Fixed in code. 4.1.0.8940590and later.
4.2.0.9392909
Release Notes
28 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
889243/06383016894517/066775767899617/85705870
After system reboot, a LUN wasfound offline and required recovery.
Fixed in code. All previousversions.
4.1.2.9257522
884837/06078875888243/06163749888793/06058875889403/84242308891929/891929
Initiators associated with ESXi hostsconfigured on the Unity system weredeleted if the ESXi hosts becameinaccessible (for example, due tonetwork outages).
Storage system no longerremoves IP addresses andinitiators when a polled ESXihost is not in a connected state.
4.1.0.8940590and later.
4.1.2.9257522
885897/06147613896082/85342914
Under particular conditions, a filesystem could go offline if a sparsefile in a CIFS share was truncated tozero.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
886933/06183101 With SMB1 signing disabled, olderclients using the SMB1 protocolwere unable to logon server usingNTLM authentication (that is,Kerberos log in was successful).
Removed unexpected SMB1signing enforcement duringNTLM SSP authentication.
All previousversions.
4.1.2.9257522
888673 When mounting a CIFS share using -t cifs on a Linux client, Unity
returned incorrect quota usageinformation and failed writerequests.
Actual file size used to calculatethe quota usage.
4.1.1.9138882 4.1.2.9257522
888131/84514514 NAS server failover processes wereinterrupted when a UFS wasundergoing a shrink operation.
Fixed in code. 4.1.0.8959731and later.
4.1.2.9257522
889870/83307948 Concurrent rename operations onfile systems with many directoriesled to an increase in latency.
Fixed in code. All previousversions.
4.1.2.9257522
889998887426/82090440893733/06329201
The system could reboot ortransition into service mode if themanagement cable was pulled or ifthere was a bad network connection.
Fixed in code. All previousversions.
4.1.2.9257522
890218880117/05787892
Jobs related to replication might notcomplete and could not be disabledwhen multiple replication commandswere issued together.
Code updated to removereplication command conflicts.
All previousversions.
4.1.2.9257522
890221879529/05787892
When multiple snapshots weredeleted, a conflict between spacereclaim and expansion could createIO time out conditions.
Fixed in code. All previousversions.
4.1.2.9257522
890222889200/06383016890563/84654700891416/84654700
Under particular conditions, relatedto handling IO cancellations aStorage Processor can unexpectedlyreboot.
Fixed in code. 4.1.0.8940590and later
4.1.2.9257522
Release Notes
Fixed in previous releases 29
Issue number Problem summary Description of fix Found inversion
Fixed inversion
890223/05497977 On NFSv4 file systems, themodification time was not updatedwhen a file was modified.
Fixed in code. 4.0.2.8627717and later.
4.1.2.9257522
890224/83714310 Jobs on block VMware datastoresfailed with completed withproblems" messages and
reported Error Code:0x5c0000c if
ESXi hosts registered on the Unitysystem used only FCoE adapters.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
890225886749/06168750
Attempting to change a remotesystem username and password withthe Unity CLI remote/sys setcommand without specifying the -connectionType option failed and
temporarily interrupted managementaccess to the Unity system.
Fixed so that Unity CLIcommand does not fail whenchanging remote username andpassword.
All previousversions.
4.1.2.9257522
890226867418/82714822
If CIFS server properties werechanged while files were opened ona Continuous Availability share, NASservers got stuck while failing backto their native Storage Processor, orwhen a file system was unmountedfrom the NAS server.
Fixed in code. All previousversions.
4.1.2.9257522
890228 SMB share names were limited to 40alphanumeric characters ratherallowing 80 characters.
SMB share names of 80characters is now allowed.
All previousversions.
4.1.2.9257522
890233884218/05890978
If a vCenter cluster included adisconnected ESXi host (that is, ahost whose status appeared asDisconnected or Notresponding in vSphere),
attempts to add the cluster as aUnity VMware host failed.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
890234/05952835
When a null sized file handle wasreturned in response to a NFSV3request, the NFS service becameblocked.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
890236/05605390
When configuring the LDAP namingservice with simple authentication, ifa base distinguish name containedthe asterisk (*) character, a Nameis not valid error was
reported.
Asterisk character recognized inLDAP names.
All previousversions.
4.1.2.9257522
890551/05830682884360/06008397
Canceling a LUN Move operationsometimes would not cancel theoperation or would cause a StorageProcessor reboot.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
Release Notes
30 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
890859893778/05811148896087/05811148
After a Unity software OE upgrade,Replication remote system entrieswere not visible in Unisphere or theUnity CLI.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
890986/06475300
Unable to connect an SSH session tothe Unity system after a Unity OEsoftware upgrade.
Fixed in code. 4.1.1.9138882 4.1.2.9257522
891084/84848062892375/84964500893307/85082924894159/06652318896986/06537033897329/06767223898189/06876045898598/06851583
The SMB server can becomeblocked if the connection with itsremote Domain Controller isinterrupted.
Fixed in code. 4.1.1.9138882 4.1.2.9257522
891137883659/06004154885120/84164804886006/06187857890542/06427457892511/06539832895173/06710745
An unexpected Storage Processorreboot occurred when storageresources were not balanced acrossthe Storage Processors..
Fixed in code. All previousreleases.
4.1.2.9257522
891182 06314414895407/85198956
After enabling a tree quota on anexisting directory, the time fieldswere modified for the directory andall of its subdirectories and files.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
891198/81804340 NAS LDAP authorization settings(bind dn) were lost when adding asecond LDAP server to a NASserver.
Fixed in code. 4.0.0.7329527 4.1.2.9257522
891201/83346816 Naming for manual and scheduledsnapshots use inconsistent timestamps in the names.
UTC time is now usedconsistently.
4.1.0.8959731and later.
4.1.2.9257522
891203/05986678 A Unity OE software upgrade wasinterrupted in the middle of theprocess, and one Storage Processorwould reboot repeatedly.
Fixed in code. 4.1.0.8959731and later.
4.1.2.9257522
891583891583/84774634892206/06523428
Storage Pool Create/Expand jobfails due to the following error:0x6700136.
Fixed in code. 4.1.0.9058043and later.
4.1.2.9257522
891813/82728840 A Storage Processor rebootoccurred when closing directoriestriggered by an SMB changenotification and handling TCPdisconnections..
Fixed in code. All previousreleases.
4.1.2.9257522
Release Notes
Fixed in previous releases 31
Issue number Problem summary Description of fix Found inversion
Fixed inversion
891869/82728840 Enabling SMB Protocol Encryptioncould cause a performancedegradation accessing the encryptedshare.
Code enhanced improveperformance when accessing anencrypted share.
4.0.0.7329527and later.
4.1.2.9257522
892183/06311742889240/06311742
The following Unity warningmessage was generated on a dailybasis: UDoctor alert: Rootpartition crossed 80%space utilization.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
892205885248/84232094
Storage Processor could go toservice mode with reason code0x1200.
Fixed in code. All previousreleases.
4.1.2.9257522
892281895079/06677748
Storage Processor can reboot whilereclaiming available space over oneTerabyte.
Fixed in code. All previousreleases.
4.1.2.9257522
892283888896/84636356893572/84979828
Under particular conditions, deletingsnapshots caused a StorageProcessor reboot and caused Unityto transition to Service Mode.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
892284/05952835 File system became inaccessibleuntil access was restored by aStorage Processor reboot.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
892528/05784193893354/85089930
Deleting a VMFS datastore andcreating a remote replication sessionto restore it before the delete hascompleted sometimes causedunexpected Storage Processorreboots to occur.
Fixed in code. 4.0.2.8627717and later.
4.1.2.9257522
892555884649/06079536894042/84201760897080/06818437898790/85466114
If a snapshot on a NAS server was inthe process of being deleted whilethe associated NAS server wasfailing back, occasionally the NASserver did not re-start.
NAS server restarts withoutwaiting for the snapshotdeletion process to complete.
All previousreleases.
4.1.2.9257522
892632/06085603884903/05934582887300/84168974887638/06060451898624/06779094
After upgrading to Unity OE 4.1.0,Unity reported unknown ESRSstatus messages in proxy-onlyenvironments.
Fixed in code. 4.1.0.9058043and later.
4.1.2.9257522
892647/84374956 The system cannot communicatewith outbound services in the172.17.0.x subnet, including thecentralized ESRS server.
Fixed in code. 4.1.1.9138882 4.1.2.9257522
892828/05841478887881/06285078890728/06306990
A Storage Processor rebootedunexpectedly while cancelling adatastore migration.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
Release Notes
32 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
893748/84848062 An SMB server became blockedunexpectedly when the connectionbetween Unity and a remote DomainController was interrupted..
Fixed in code. 4.1.1.9138882 4.1.2.9257522
893849/ 5027422895549/85144502
A Storage Processor experienced anunexpected reboot when the SP wastrying to reclaim space and abackground operation failed.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
893866/06555924
When performing Compress Nowoperation to a LUN with active I/Odelays in the I/O response times mayoccur.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
894609/85097434 Attempts to delete a consistencygroup that was used as replicationdestination failed. In addition,attempts to rename it causedunexpected Storage Processorreboots.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
894645/06566672892540/06566672
Under particular conditions, whenILC was enabled on a Unity LUN butno data was written, or whenincompressible data was written, thesystem could experience anunexpected Storage Processorreboot.
Fixed in code. 4.1.1.9138882 4.1.2.9257522
895579/896049/06566914
Under particular conditions with arandom NFSV4.1 IO load, a StorageProcessor reboots could occurleaving and associate file systemswould be reported as offline.
Fixed in code. All previousreleases.
4.1.2.9257522
895715/85324384 After upgrading to the Unity OEsoftware, if the Active Directorydomain name did not contain a dotcharacter CIFS clients could notaccess the SMB storage becausedirectory services were not availablethrough the Domain Controller.
Active Directory domains notcontaining dot charactersaccepted as valid domains.
4.1.1.9138882 4.1.2.9257522
895766/06703340895301/06703340
Under particular conditions wheninternal activity was triggered on anunmounted file system, anunexpected Storage Processorreboot could occur.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
895986/06489073 Under particular conditions,migration performance would benegatively affected due to excessivelogging of internal messages.
Logging enhanced to negateany performance impact.
4.1.1.9138882 4.1.2.9257522
Release Notes
Fixed in previous releases 33
Issue number Problem summary Description of fix Found inversion
Fixed inversion
878528/83553316 NAS Servers and file system sharessometimes became inaccessibleduring restore operations to DHSMstub files created with Cloud TieringAppliance software. The StorageProcessor then rebooted toreestablish access.
Fixed in code. All previousversions.
4.1.2.9257522
880055/05787892879581/05787892883116/05792298895541/06733676
Thick LUNs with snapshotssometimes went offline if a racecondition occurred met when IO wasdirected at a region where spacewas being reclaimed.
Fixed in code. 4.0.2.8627717and later.
4.1.2.9257522
884169/05849405889194/06384087889352/06393738890091/84805504
File systems can becomeinaccessible after a StorageProcessor reboot.
Fixed in code. 4.1.0.8940590and later.
4.1.2.9257522
857622 When importing an NFSconfiguration from VNX to a UnityVMware NFS datastore, the job failsas expected. However, the failureerror message is inaccurate:Failed: Create sessionfails with {0} error(s).Please check message by scp{1}@{2}:{3}/.migration/precheck_vdm_{4}.log.(Error Code:0x9000194)" -This error message is notfilled with parameter valuein.
The error message shouldactually say that the job failswith at least 1 error.
4.1.0.8940590and later.
4.1.1.9138882
84365598/888130
A user experienced a system bugcheck with a buffer cache free issueor file system corrupted due to anincorrect metadata error.
The code has been updated tobypass the I/O performanceoptimization for avoiding datacopy to avoid this issue.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.8194551
4.1.1.9138882
84070110/ 886390 A hot fix became inactive andneeded to be reinstalled. Thishappened when the hot fix wasapplied to a system and then a re-image operation was performed onthe system.
The code has been updated toallow an existing hot fix to berestored during a re-imageoperation.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
84260722/ 886018 A replication session was not able touse its full bandwidth. Thereplication session had lowthroughput, despite there being nocongestion or other issue in thenetwork. This is due to the
The replication high watermarkand low watermark settingshave been removed. The codehas been updated to remove therestrictions that caused thisissue.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
Release Notes
34 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
restrictions by the sender totransmit more data and receiver toreceive more.
05894988/06216865/06197446/06171008/ 886462
This issue presented itself in severalways:
l A user was unable to access fileshares.
l Storage processors entered abug check phase after anupgrade.
l Slow I/O response time wasexperienced on an all flash array.
The code has been updated tofix an issue related to thereservation of system resourcesused for I/O processing.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
883786 An import session entered a lostcommunication status when a
network disruption occurred. Thesession was stuck in that state. Theonly option for the user was tocancel that import session and startit again.
The code has been updated toavoid this issue.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
05462668/883124
A user experienced the inability toread and/or write recently expandedregions of bound block (SCSI)VVols.
The code has been updated sothat block VVols that are newlybound after an upgrade can beread and/or written immediatelyafter expansion throughvSphere. Pre-existing bindingsfrom before an upgrade willneed manual purging, which isnormally achieved by shuttingdown the virtual machine.
4.0.1.84041344.0.1.83201614.0.1.8194551
4.1.1.9138882
05894988/882436
While moving an existinguncompressed LUN to a compressedLUN, an application using that LUNexperienced an unexpectedly largeincrease in response time for smallor unaligned writes.
The code has been updated andnow the library used to movethe LUN has been modified toavoid long response times forsmall or unaligned writes.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
83953636/882328
An export became inaccessible forthe clients belonging to that subnetafter the specific access for asubnet was modified. The mask ofthe subnet became255.255.255.255.
The code has been updated tothat the subnet mask is nowcorrectly preserved.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
05830682/881448
A storage processor unexpectedlyre-booted while writing I/O to inline-compression enabled LUNS.
The code has been updated tofix the issue that triggered theunexpected reboot.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
05785720/879344
A storage processor unexpectedlyre-booted during an internal spacerecovery operation.
The code has been updated tofix the issue that resulted in theunexpected re-boot.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
Release Notes
Fixed in previous releases 35
Issue number Problem summary Description of fix Found inversion
Fixed inversion
82779744/ 873301 After a failover, an NFS client took aunexpectedly long time beforerestoring access to its exports.
The code has been updated toreduce the time to restoreaccess to exports after afailover.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.8404134
4.1.1.9138882
74599468/ 881706 In a configuration with RecoverPointthe storage processor rebooted witherror code: E117B264.
The code has been updated tohandle the condition thattriggered the storage processorto reboot.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.81945514.0.0.7329527
4.1.1.9138882
77632114/ 878057 The RecoverPoint splitter on thestorage processor becameunresponsive and did not recoverautomatically. A reboot of thestorage processor was required torestart the splitter.
The code for the restart wasupdated to fix the issue thatmade the reboot necessary.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.81945514.0.0.7329527
4.1.1.9138882
81914690/ 872873 When a user executed an szcommand in svc_service_shellto retrieve a file from the storageprocessor, the file will be logged intosvc_service_shell.out.
The code has been updated todisallow sz in
svc_service_shell. Now a
warning is issued, The szcommand is disabledin svc_service_shell.
If you need to use sz, exit
svc_service_shell and
retry sz. Or use WinSCP or a
similar utility to get files off thesystem.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.81945514.0.0.7329527
4.1.1.9138882
5252987/ 882108 An NFS 4.1 client lost access to theNFS exports if the client mounts filesystems from another NAS serverand both NAS servers resided on thesame storage processor.
The code has been updated sothat the client is able tomaintain more than one sessionto multiple NAS servers on thesame storage processor.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.8404134
4.1.1.9138882
5745989/ 881720 The RecoverPoint splitter on thestorage processor repeatedlyrestarted unexpectedly.
The code has been updated togracefully handle the conditionstriggering the repeated restarts.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.8404134
4.1.1.9138882
5894841/ 881370 During an upgrade or a reboot, theESXi hosts lost access to thestorage system if the storagesystem poll the vCenter of the hostsfails.
The code has been fixed toensure the storage system willno longer update ESXi hostinitiators for which the storagesystem is unable to pollvCenter.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
Release Notes
36 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
5784193/ 879921 Unisphere defaulted to automaticallyselect the first row in a table. Thisdesign led to confusion andunintended objects being selectedfor operations.
Unisphere has been updated sothat first row is no longerautomatically selected. Thischange affects pages that showa grid on the left and a detailspanel on the right. For somepages that have no detailspanel, the first row may still bepre-selected.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.8194551
4.1.1.9138882
5734785/ 879152 ECOM stopped working and failed torestart.
New checks have been added tothe code to prevent the ECOMfailure.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.8404134
4.1.1.9138882
81540922/ 876801 From a Windows host, Quotadisplayed a greater used capacitythan was actually being used.
The code has been updated toaccurately calculate the Quotausage for a Windows host.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.81945514.0.0.7329527
4.1.1.9138882
5586609/ 874220 A NAS server was in need ofrecovery.
The code has been updated toaddress the issue triggering theneed for recovery.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.81945514.0.0.7329527
4.1.1.9138882
873870 A user was unable to create aVMware VVol data store with acapability profile allocation greaterthan 16Tb.
The code has been updated toremove this limitation.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
82334668/873402
CIFS shares were unaccessible. Theserver didn't respond to servercommands and reported Input/output error.
The code has been updated todetect and resolve a conflictbetween an offload read and aconflict triggering the error.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.81945514.0.0.7329527
4.1.1.9138882
5378990/ 871277 The mode bits generated from theACL was wrong when the file ownerwas a group, such as domainadministrators.
The code has been updated sothat the mode bits aregenerated using the SID of theconnected user when a file iscreated by SMB.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.8320161
4.1.1.9138882
Release Notes
Fixed in previous releases 37
Issue number Problem summary Description of fix Found inversion
Fixed inversion
4.0.1.81945514.0.0.7329527
5336141/ 868106 A file system went offline with thefollowing message: Unmountingfs 536870965: Reason:removeHLDBRecord: recordmissing from HLDB file.
The code has been updated tofix an issue which waspreventing the update of theHLDB record for a file whenbeing moved from one directoryto another.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.8404134
4.1.1.9138882
82044704/867789
A suspended job related to a VVoloperation was erroneously retainedin the system job database. Thisprevented the user from starting asystem software upgrade.
The code has been updated tofix this problem.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.81945514.0.0.7329527
4.1.1.9138882
5168225/ 865970 During the initialization phase of aNAS server, a user was able toaccess a CIFS server using the sharec$ and access file-systemmountpoint.
The code has been updated todeny access to the share c$during the initialization phase ofa NAS server.
4.1.0.90580434.1.0.89597314.1.0.89405904.0.2.86277174.0.1.84041344.0.1.83201614.0.1.81945514.0.0.7329527
4.1.1.9138882
867616 When cancelling an NDMP backupprocess from an NDMP DirectMemory Access (DMA) application,the operation hangs with the statusCancel in Progress on the
NDMP DMA application.
Restart the NDMP DMAapplication to discard the canceloperation, then continue withany further NDMP operations.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.1.9138882
866056 / 865456 The user is no longer able to set theconsistency group access (eitheradd a new host or remove a host) atthe consistency group level if theyhave set individual member LUNaccess.
Navigate to the member LUNstab in the Unisphere and add orremove host access to eachLUN individually. Navigate tothe consistency group, double-click to edit properties, and
select the LUNs tab. Thenselect a member LUN, double-click to edit properties and click
the Host Access tab tochange the access.Alternatively, use the UnisphereCLI to set host access at theconsistency group level.
4.1.0.90580434.1.0.89597314.1.0.8940590
4.1.0.8959731
881934 During a software upgrade from4.0.x to 4.1.0.x, the upgrade fails(usually at 62% complete) and mayhave difficulty automaticallyrecovering due to a database
This issue has been resolved inthe code.
4.1.0.89597314.1.0.89405904.0.2.86277174.0.1.81945514.0.1.8320161
4.1.0.9058043
Release Notes
38 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
schema mismatch. Although thesystem can still be pinged, Unisphereand the CLI are unresponsive.
4.0.1.84041344.0.0.7329527
881933 During software upgrade, theupgrade fails (usually at 62%complete) when a process times outwhen trying to access an EMCcatalog server.
This issue has been resolved inthe code.
4.1.0.89597314.1.0.8940590
4.1.0.9058043
881932 When moving a LUN, the operationcould hang. Refer to Knowledgebasearticle 000492043 for details.
This issue has been resolved inthe code.
4.1.0.89597314.1.0.8940590
4.1.0.9058043
877558 Some storage processors have beenseen to have reboot events,resulting in a full reboot of thestorage processor without a fault.
This issue has been resolved inthe code.
4.1.0.89405904.0.2.8627717
4.1.0.8959731
85173983426854/87559605557939/873175
A LUN or file system may go offline. This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
841151 /841149 The service commandsvc_initial_config script failed
when attempting to setup an IPv6address with zeroes in the hexnumbers for a mgmt_vdev interface.
For example:svc_initial_config -6"2a00:0da9:ff03:030f:0:2139:3853:0101 642a00:0da9:ff03:030f:ff2e::1would fail.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
810489 When provisioning a replication
destination, the No DataMovement tiering policy can beselected, although it is notsupported.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
850281 The file system went offline and amessage similar to the followingappeared in the logs::UFS: 3:[fs-name] PanicAvoidance found <fsid>corrupted(metadataDupReadBlockfailed: non-recoverablefault) sade:UFS: 3:[fs-name] metadataDupReadBlock:fsid:<fsid> non-recoverablefault bn <block number>[DIRECTORY_IO]
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
Release Notes
Fixed in previous releases 39
Issue number Problem summary Description of fix Found inversion
Fixed inversion
833537/ 832571 The "from" email address fromwhich system alerts are sent couldnot be modified.
The From Email Address cannow be customized in
Settings > Alerts > Emailand SMTP.
All previousversions.
4.1.0.8940590
832808 When an IPv4 management address
was set to Obtain an IPv4address automatically andECOM failed over to the secondarystorage processor, an SMTP serverconfiguration failed with the error:Cannot configure an IPv4SMTP server without firstconfiguring a managementport IPv4 address.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
833479 If a user uploaded a password-protected certificate using theService commandsvc_custom_cert, the system
went into a rolling reboot and thenwent into service mode. This causeduser data to become unavailable.
This issue has been resolved inthe code. The code now rejectsthe upload of a password-protected certificate andreturns a message indicatingthat a certificate that is notpass phrase-protected must beused.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
833887 Win10 and Win12 introduced newspecial SIDs, which are part of theKerberos credentials. As these aren'trecognized by the system, they'resent to the Domain Controller (DC).This overwhelmed the system andno communication with DC couldtake place with Kerberosauthentication.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
834461 After installing the first release ofbadlock patches on Samba, runningsmbclient -l against the DM
failed with output :ntlmssp_handle_neg_flags: Gotchallenge flags[0x60898201]- possible downgradedetected!missing_flags[0x00000010] -NT code 0x80090302NTLMSSP_NEGOTIATE_SIGNSPNEGO(ntlmssp) loginfailed: NT code 0x80090302session setup failed: NTcode 0x80090302 Error withSigning enabled: NTLMSSPNTLM2 packet check faileddue to invalid signature!
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
Release Notes
40 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
session setup failed:NT_STATUS_ACCESS_DENIED
835206/ 832078 The power supply firmware upgradefailed.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
838729 ESXi hosts with FCoE adaptersconnected to a zoned FC switch
were displayed in both the Hostspage and the VMware hosts pagein Unisphere.
The code has been updated toenable matching VMware hostswith FCoE initiators andautomatically connected Hosts.
All previousversions.
4.1.0.8940590
841873 When the 16G Fibre Channel HBAport was attached to a switch as a"Public Loop", the storage processorbug checked with the followingerror:FC_API_INVALID_TOPOLOGY0x03b03076.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
842169 Centralized ESRS could not beenabled because support credentialscannot be validated on a private LANwithout external connectivity.
The code has been updated toallow support credentials to besaved, although they cannot bevalidated in a private LAN/before a connection isestablished to the centralizedESRS server. These credentialscan then be saved for when theIP address of the centralizedserver is entered by the user.Fully enabling ESRS requiresthat the centralized ESRSserver has external networkaccess to EMC.
All previousversions.
4.1.0.8940590
842366 If a Unity system's site informationcontained non-English characters, aFailed to valid OTP error
appeared when configuringintegrated ESRS.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
847401 A software issue could potentiallyprevent a failed over VDM fromreturning to its default storageprocessor when that storageprocessor came back online.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
849334 Both storage processors enteredService Mode due to a large numberof snapshots.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
851033 A software upgrade session was
incorrectly labeled as In-progresswhen it actually had failed. Thisoccurred when the primary storage
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
Release Notes
Fixed in previous releases 41
Issue number Problem summary Description of fix Found inversion
Fixed inversion
processor was rebooted and comingback online.
855255 Access to the LUN was lost during astorage processor reboot.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
855964 In Japanese, the test alert emailsubject line used the wrongparameters and was incorrect.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
856071 A host lost connectivity with theUnity system after a host panic andcould not access Unity LUNs. Thehost status in Unisphere appeared asdegraded with no associatedinitiators.
This issue has been resolved inthe code by preserving hostaccess to Unity even after ahost is disconnected anddegraded.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
857748 A filename with an invalid UTF-8string was mistaken for a validUTF-8 string and was saved asunicode. The list of the filenamesshows the UTF-8 encoding of thestored name, not the original name.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
858490 CIFS share could not be mountedfrom a Linux client using the Sambamount command if NFSV2 byNTLMV2 authentication is enforced.
The code has been updated toaccept and handle NTLMv2authentication for client usingold SMB1 authenticationrequests.
All previousversions.
4.1.0.8940590
859146 / 862102 After a short-duration power outage,the storage processor hung insteadof rebooting with a CPU IERR error.
This issue has been resolved inthe latest firmware in the code.
All previousversions.
4.1.0.8940590
802882 There is an extra Configure stepwhen installing a hotfix with the
Software Upgrades Wizard .The Configure step does not applyto hotfixes.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
804943 (physicaldeployments only)
After replacing or upgrading thefirmware on a four-port 10-Gb/soptical I/O module, the systemindicates that the I/O module isfaulted in the Unisphere CLI andUnisphere. The storage processorenters service mode as a result.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
805069 When multiple back-to-backrequests to change host access aresent to the same consistency group,the results are a mix of the requests.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
808848 If an object has existed for less timethan the interval displayed in theperformance over time charts in
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
Release Notes
42 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
System > Performance, no datawill be displayed.
809674 Batch jobs that are deleted using theUnisphere UI may contain jobs thatremain visible in the Unisphere CLI.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
811803 When creating a snapshot while afile system expansion is taking place,the following error appears:Operation failed. Errorcode: 0x6000bbc The systemwas not able to create asnapshot. Please check thatthe storage pool is notfaulted or out of space, orthat the source is not inan invalid, offline, ordestroying state, andretry. Otherwise see thelogs for details thensearch for the error codeon the support website orproduct forums, or contactyour service provider, ifavailable. (Error Code:0x6000bbc)
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
816362 After creating a thick file systemwith a size of several TBs, there is aperiod of time where a file systemsnapshot cannot be taken.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
817768 After removing ESXi host access,the host reports a major issue inUnisphere.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
818677 A pool may report degraded statusfor exceeding capacity threshold,when the allocated space is not atthe threshold.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
821276 Using the same snap schedule onmany resources may slowcompletion of other commandsexecuting at the same time as theschedule.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
821411 In Unisphere, the Base Port andManagement Port details dialogbox does not report the IP Address,Gateway Netmask, or VLAN IDvalues
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
Release Notes
Fixed in previous releases 43
Issue number Problem summary Description of fix Found inversion
Fixed inversion
827788 An upload initiated from Unisphereor using the REST API that takesmore than 10 minutes to completefails. An error message similar to thefollowing displays: {"error":{"errorCode":131149826,"httpStatusCode":503,"messages":[{"en-US":"The system is busy.Try again later. If theproblem persists, searchfor the error code on thesupport website or productforums, or contact yourservice provider, ifavailable. (Error Code:0x7d13002)"}],"created":"2016-05-24T19:46:13.121Z"}} '
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
836269 Saving the system configurationwhile an upgrade is in progress is notsupported. The Unisphere CLIcommand /service/systemcollect -config may incorrectly
report success.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
841739 If a storage resource previously hada replication session configured anddestroyed, an attempt to create areplication session on the storageresource may fail with an internalerror.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
855190 An existing ESXi host configurationcan be overwritten when a ESXi hostis added as an existing host, if theadded host has a vmKernel IP that isalready in use. This occurs even ifthe vmKernel IPs are on privatevSwitches. Unisphere displays thefollowing message when adding astandalone ESXi host: Matchessome network address ofhostxxx. Importing thiswill replace existingconfiguration. Unisphere
displays the following message whenadding ESXi hosts from a vCenter:Conflicts with one or moreip addresses of otherpotential host. It isrecommended to resolvethese conflicts beforeimporting to avoid
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
Release Notes
44 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
misconfiguring the hosts. If
the attempt to add the host is notcancelled and the operationcompletes, the original host(hostxxx) will lose access and thenew host will assume its identity.
793285 When a consistency group is createdas a replication source anddestination, creating a replicationsession may fail with the followingmessage: Operation failed.Error code: 0x6000003 Thesystem encountered anunexpected error. Try againand if that attempt failsthen search for the errorcode on the support websiteor product forums, orcontact your serviceprovider, if available.(Error Code:0x6000003)
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
814766 Certain user operations on adeduplicated file incorrectly causedauto-extension enabled file systemto extend to the maximum size. Theextension size can be max_size,space available in the pool, or 16TB(whichever is lower). Messagessimilar to the following may be seenwhen the problem istriggered. /nas/log/webui/apl_tm.log:------------------------------------------- webui-N:[root@localhost]:0:3681:S:1926601-Execute legacycommand [/nas/sbin/fs_extend_handler Sep 2511:18:39 2013 DART:CFS:4:6Slot 2: 1380125919: FsId:2957 MaxSize: 5242880 MBHWM: 95%. Forced ExtensionSize=35232152 MB] sys_log:------------ fs autoextension forced ext start:[data03_home] max_size:5242880 hwm:95(Slot2:1380125919:)server_log:----------------- DHSM: 3:getOnline: Couldn't reserve
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
Release Notes
Fixed in previous releases 45
Issue number Problem summary Description of fix Found inversion
Fixed inversion
-1 blocks for inode3976589. Error encoutered -NoSpace
816346 The Data Mover (DM) was notresponding to SMB/CIFS or NFSclients. SMB threads on the DMwere blocked. DHSM was in use onthe system and a DHSM connectionwas being modified.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
817848 For Pools with associated VVols,storage that is taken up by VVols isincorrectly displayed in Unisphere
under the Snapshot Used column
in Pools.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
819524 When ESRS is enabled, it may takeup to one minute for users to seesome support links the first time
they access the Support page.
This issue has been resolved inthe code and performance isnow improved.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
823778 An IO module could not bereconfigured.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
828444 The Create Pool operation timed outwhen system drives were selectedfor the pool creation. A messagesimilar to the following wasdisplayed: The system failedto create the RAID group.The disks might still beinitializing. Try againafter few minutes. If theoperation continues tofail, search for the errorcode on the support websiteor product forums, orcontact your serviceprovider, if available.(Error Code:0x6700135)"
Starting in Unity OperatingEnvironment 4.1.x, systemdrives can be used to createpools.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
836555 When using both VMFS and BlockVVol datastores over iSCSI, errorshave been reported when creatingswap VVols during VM power-on.This was caused by incorrectremoval of the iSCSI targetdiscovery IP addresses for thesoftware iSCSI adapter on the ESXihost.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
836955 The file system may have goneoffline when the last snapshot isdeleted for that file system.
This issue has been resolved inthe code.
All previousversions.
4.1.0.8940590
Release Notes
46 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
840320/ 844001 The System Limits page underSettings did not include VMFSdatastore limits.
These limits now display in thisrelease.
All previousversions.
4.1.0.8940590
841011/ 849251 After a snapshot session wasdeleted, it still displayed inUnisphere.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
842096 A NAS server had NIS servernetwork connectivity issues whenboth the NAS server and NIS serverwere configured with IPv6.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
843845 On a Unity 300 system, the progresspercentage % for a replicationsession for consistency groups mayhave been inaccurate when therewere eight or more LUNs in aconsistency group.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
844099 Some virtual machines (VMs) storedon VVol datastores becameinaccessible after a softwareupgrade from Unity 4.0.0.x to4.0.1.x.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
853379 iSCSI protocol endpoints appearedin Unisphere as assigned to a host,but did not appear in vSphere afteran ESXi host HBA rescan.
This issue has been resolved inthe code.
4.0.2.86277174.0.1.81945514.0.1.83201614.0.1.8404134
4.1.0.8940590
863861 If a storage processor was shutdown incorrectly or power was lostwhile shutting down, it restartedwith a hard reset. The issue maymanifest as a storage processor thatdoes not start up normally.
This issue has been resolved incode.
4.0.1.8404134 4.0.2.8627717
814463 The FAST Cache shrink operationfailed with the following error: FASTCache is currently busywith another operation.Please wait for all jobs tocomplete before attemptingany additional operationson FAST Cache. (Error Code:0x6700165)
This issue has been resolved inthe code.
4.0.0.7329527 4.0.1.8194551
821738 (virtualdeployments only)
When a user opens the
Performance dashboard in
Unisphere and adds a Cache DirtySize chart, the values in the chartare all zero.
This issue has been resolved inthe code.
4.0.0.7329527 4.0.1.8194551
Release Notes
Fixed in previous releases 47
Issue number Problem summary Description of fix Found inversion
Fixed inversion
810049 (physicaldeployments only)
Starting a FAST Cache operationimmediately after starting a poolmodification operation may result inthe following error message:Operation failed. Errorcode: 0x6700165 Pleasewait for all jobs tocomplete beforeattempting anyadditional operations onFAST Cache. (Error Code:0x6700165)
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
789487 / 823304 Hosts connected to iSCSI CNA andtwo-port 10Gb/s optical I/O moduleports experienced 30–40 seconds ofconnectivity loss due to a firmwareissue that caused the device tobecome unresponsive. The internaldriver software automaticallyrecovered the device by beginning adevice reset. During this time, thephysical link bounced on both CNAports and two-port 10Gb/s opticalI/O module ports.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
794675 (physicaldeployments only)
The following critical alert for theDPE was generated during the SLICcommit process: The DiskProcessor Enclosure(DPE) has faulted. Thismay have occurredbecause of a faultedsubcomponent. Identifyand fix the issue withthe subcomponent. If theproblem persists,contact your serviceprovider.
This issue has been resolved incode
4.0.0.7329527 4.0.1.8194551
801562 / 812461 After configuring LDAP on a NASserver, the server health error LDAPnot connected appeared.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
804317 (physicaldeployments only)
The help link for the disk tab of the
Create Pool Wizard opened the
Welcome help screen instead of
the Disk Types help screen.
The link now opens the correcthelp screen.
4.0.0.7329527 4.0.1.8194551
809346 When changing the Secure NFSsetting from Use SMB serveraccount to Use custom realm on aMaster User Profile (MUP) NAS
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
Release Notes
48 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
server, a dialog box confirmingdeletion of an SMB server from theActive Directory domain appeared.
809332 / 810799 Users could not delete snapshotswith an in-band request through thesnapshot SMP.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
810159 / 811562(physicaldeployments only)
Trying to create a pool immediatelyafter starting a FAST Cache createoperation resulted in the followingerror message in Unisphere:System encounteredunexpected error.....(Error Code: 0x7d13001)
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
810919 / 812459 The jobs list showed blank rows. This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
811216 / 812250 Users may not have been able todestroy a file system that waspreviously in use by replication.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
811237 If the replication interface IP addresswas the same as the broadcast orsubnet address for the network, thereplication session failed.
The system no longer allows thebroadcast or subnet address tobe used as the interface IPaddress.
4.0.0.7329527 4.0.1.8194551
811413 / 812762 The replication session failed withthe status DestinationExtend Failed NotSyncing, indicating a failure while
expanding the destination filesystem.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
811509 / 814045 The preferred IP interface setting onthe replication destination was outof sync with source, resulting in anissue on the destination if a failoveroccurred before resynchronization.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
811856 (physicaldeployments only)
After an AC power failure of lessthan a few seconds, a good powersupply was incorrectly marked asfaulted.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
811890 A user pool creation operation mayfail with the error code 0x670150b.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
812022 Creating a share or export fails withthe error code:0x900a117
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
812052 When creating a host fromUnisphere an error with code0x7d13001 is reported.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
Release Notes
Fixed in previous releases 49
Issue number Problem summary Description of fix Found inversion
Fixed inversion
812091 When a LUN was added to aConsistency Group, the job details
were not displayed on the JobProperties or Result pages.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
812703 The Acknowledged column in the
Alerts table was blank.
The Acknowledged column in
the Alerts table will display thecorrect values.
4.0.0.7329527 4.0.1.8194551
813509 (physicaldeployments only)
In Unisphere the Support page mayhave taken up to a minute to load.
The Support page now loadswithout delay.
4.0.0.7329527 4.0.1.8194551
813659 (physicaldeployments only)
If FAST Cache was deleted with theREST API URL /api/instances/fastCache/0/action/disableand a timeout parameter value waseither not specified or was set to -1,the job stopped responding andnever deleted the FAST Cache.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
813764 (physicaldeployments only)
The user is sometimes allowed tocreate a pool that included faulteddrives.
The system will prevent the poolfrom being created with faulteddrives.
4.0.0.7329527 4.0.1.8194551
813867 When file systems are defined in adifferent pool than their NAS server,if the pool for the file systemsbecomes degraded, once the pool isrecovered, the NAS server statemay stay in degraded mode.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
814001 The Unisphere CLI command /event/alert/hist showincorrectly displayed the ID attributeas "Id."
The output text has beencorrected.
4.0.0.7329527 4.0.1.8194551
814113 Setting a value for the MaximumTransmission Unit (MTU) on aniSCSI-configured port did not takeeffect until the storage processorwas restarted.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
814562 When ESRS was enabled, audit logsindicated that a service user ran thecommand svc_udoctor -jobs -xx, but the system automatically
launched this command.
The audit logs report thecorrect action.
4.0.0.7329527 4.0.1.8194551
814724 Support contract information did notautomatically refresh.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
814932 Creation of a replication session mayhave failed with error code0x650015d. This was an infrequenterror.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
Release Notes
50 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
815374 (physicaldeployments only)
The ESRS integrated wizard failedwith the error message:0x6400ba4, Failed tovalidate site id forRemote Support.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
815447 If a client application was expectingto use File Delegation with theNFSv4 protocol, there wereperformance issues. File Delegationwas not granted when needed.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
816272 After switching the Management IPfrom Automatic to Manual withoutchanging the IP address, thefollowing error message appeared:The specified IP addressis already in use (ErrorCode:0x716e00a)
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
817541 (physicaldeployments only)
The number of LUNs that could beprotected by RecoverPoint wasbelow the expected limit.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
817971 When enabling or disabling the SSHon the system using the servicecommand svc_ssh, the SSH status
was displayed incorrectly inUnisphere.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
818420 In the service mode, Unisphere onlydisplayed English after login.
In the service mode, Unispherenow displays the correct locale.
4.0.0.7329527 4.0.1.8194551
818701 Running the service commandsvc_smtpcheck did not work.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
819461 When the management IP addresswas changed, the IP address was notupdated in ESRS. After changing theIP address, ESRS was unable toconnect.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
819852 In the Spanish language, someobjects in Unisphere are displayed asEnglish, including system limitations,log messages, and links on the
Support page.
These resources are nowcorrectly localized.
4.0.0.7329527 4.0.1.8194551
821064 Asynchronous replication of blockdevices between a Unity system anda VNXe3200 did not work.
VNXe3200 required theapplication of VNXe32003.1.5.6801782 service pack orhigher on the VNXe system.
4.0.0.7329527 4.0.1.8194551
822799 The Online Training link in the
Support page of Unisphere did notalways load.
The link has been updated. 4.0.0.7329527 4.0.1.8194551
Release Notes
Fixed in previous releases 51
Issue number Problem summary Description of fix Found inversion
Fixed inversion
823446 (physicaldeployments only)
The storage processor's mode tookseveral minutes to update after asecondary storage processor wasplaced into or recovered fromservice mode.
The storage processor modeshould update when it isavailable.
4.0.0.7329527 4.0.1.8194551
825944 (physicaldeployments only)
After a primary storage processorwas placed into service mode orfailed over, the ESRS connectionstatus was "Unknown."
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
826226 (physicaldeployments only)
An incorrect 503: ServiceUnavailable error message was
displayed when trying to configureintegrated ESRS.
The error message has beencorrected.
4.0.0.7329527 4.0.1.8194551
829164 A block VMware datastore could notbe created from Unisphere if it waslarger than 16TB.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
832178 Execution of svc_drive_statscommand was limited to the rootuser.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
835464 While provisioning embedded ESRS,if the download step was notsuccessful, it was unable to beretried.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
836866 /836068 /836924 /80291634
The Support page in Unisphereshowed "No License Installed" afterlicense installation, when all licensesare permanent and have noexpiration date.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
838740 When multiple paths wereconfigured to each storageprocessor in conjunction with theESXi MPIO driver, failover timesmay have been extended.
Failover times in this situationhave been reduced.
Note
Systems with this configurationmay experience this issue duringthe failover induced duringupgrade until the new OE withthe fix is running on the system.
4.0.0.7329527 4.0.1.8194551
845581 Configuring an SMTP server viaUnisphere or Unisphere CLI mayhave failed.
This issue has been resolved incode.
4.0.0.7329527 4.0.1.8194551
849738 / 849946 Statically configured DNS settingswere removed for the managementnetwork after upgrading to4.0.1.8194551.
Statically configured DNSsettings for the managementnetwork remain configured afterupgrade.
4.0.1.8194551 4.0.1.8320161
851317 The file /nas/http/logs/mod_jk.log was not rotated, and
The file /nas/http/logs/mod_jk.log is now rotated.
4.0.1.8194551 4.0.1.8320161
Release Notes
52 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Issue number Problem summary Description of fix Found inversion
Fixed inversion
may have resulted in the /nas file
system on the storage processorbecoming full.
854248 During an upgrade not all log fileswere properly rotated or truncatedprior to the upgrade starting, andcaused file system utilization toreach 100%.
This issue has been resolved incode.
4.0.1.8320161 4.0.1.8404134
854537 After upgrading, access toIntegrated ESRS was lost.
This issue has been resolved incode.
4.0.1.8320161 4.0.1.8404134
Known issuesIssues identified for this release.
Issues affecting Unity physical deployments only and workarounds that differ forUnityVSA are noted. Issues affecting UnityVSA systems only are in Table 3 on page71.
Table 2 Known issues
Issuenumber
Problem description Workaround / Resolution Exists in version
932347 When creating or deleting a Fail-safe networking(FSN) instance, Unity generates an alert(14:60edb, One of the system'sstorage processors cannot communicatewith FSN port %2") that is shown in the
Unisphere Alert page. However, the FSN behavesnormally in this case and this alert is a false alert
Ignore the FSN (14:60edb)
alert.
4.2.1.9535982
930868 When using Unisphere to delete snapshots, theUnit deletes the user snapshots but not thesystem snapshots. This is expected behavior.However, Unisphere may indicate that thesnapshot deletion process failed.
Ignore the messages indicatingthe snapshot deletion jobs havefailed.
4.2.1.9535982
930652/930654
After you perform the initial license installationprocess on a new Unity system, and you havecompleted all of the necessary steps in the InitialConfiguration Wizard, Unisphere may not show allof the licensed features as enabled.
Refresh the browser window inthat you are using to accessUnisphere.
4.2.1.9535982
930319 Snap restore operations can fail when theassociated storage pool resources are out ofspace.
Remove the failed snapshotoperation and rollback the objectby using the MluCli tool as shownbelow:
MluCli.exe destroysnap -srvc_cmd -oid <snapoid> -system
4.2.1.9535982
Release Notes
Known issues 53
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
MluCli.exe objectops -b_careful -destroy -oid<snap rollback oid>
929676 When LUN migration is taking place and thedestination storage pool is full, the LUN migrationprocess can hang (for up to two hours). Duringthat period, you cannot pause or delete themigration session.
Wait until the session enters afailed state, and then delete themigration session and re-migratethe source LUN.
4.2.1.9535982
929658 Under unusual conditions, when you create asnapshot or when a scheduled snapshot operationoccurs during a Unity space reclaim operation,Unity can perform an unexpected storageprocessor (SP) reboot.
The snapshot operation resumesafter the SP reboot.
4.2.1.9535982
929455 When using Unisphere with Google Chrome, afterupgrading the Unity OS from 4.2.0 to
4.2.1.9505708, when choosing Settings >
Access, the High Availability page does notappear.
Clear the Chrome browser cacheand try again.
4.2.1.9535982
929442 If a Unity storage processor (SP)reboots while aNAS Server is being moved, Unity returns thefollowing error message:
Failed to initialize NAS serverreplication service in target SP.(Error Code:0x6720667).Job ID %3D N%2D78469]
Reboot the target Unity SP,reboot the other Unity SP, andthen try move the NAS Serveragain.
4.2.1.9535982
929343 Users cannot access files or directories associatedwith a ACL IDs with bad reference counts. Whenthis occurs:
Clicking on the file/directory produces the errormessage xxx is not accessible, oneinternal error" .
Right clicking file, and selecting Properties >Security produces the error message Therequested security information iseither unavailable or can't bedisplayed.
Using the Windows command line icacls.exe to setthe ACL data produces the error message XX :An internal error occurred .
4.2.1.9535982
929099 Snapshot restore operations can fail if theassociated storage pool is out of space.
4.2.1.9535982
928824 After an unexpected power interruption, LUNsmay not come back online automatically.
Perform a unit storage processorreboot.
4.2.1.9535982
Release Notes
54 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
928421 Under unusual conditions, pool creation time maytake up to ten minutes.
4.2.1.9535982
927381 When a storage pool is low on space, creating anew snap on a LUN (for instance, though asnapshot schedule or replication operation), thencreate snap may fail and host may fail to accessLUN.
Avoid low-space storage poolconditions by keeping sufficientavailable storage.
4.2.1.9535982
927349 Under some conditions, cannot deleteasynchronous replication sessions (the deleteoperation hangs).
Perform a storage processorreboot and attempt the deletionagain.
4.2.1.9535982
927075 When running UEMCLI commands, Unity systemscan return error messages such as InternalError or Storage server unavailable.
Reboot the Unity OS. 4.2.1.9535982
919378 After re-installing VSS hardware provider, the VSSfails to create snaps or import snaps. This problemis found only during a re-install (uninstall andreinstall). Either the HwProvider.log file missingfrom C:\Program Files\EMC\Unity\VSSHardware Provider\log or the HwProvider.log filedoesn't get updated during the shadow operations.In addition, the UnitySnapshotProvider servicecould also be missing in services.
During the re-install, the "Create Windows servicerunning as Local System" step fails with error thatcan be found in C:\Program Files\EMC\Unity\VSS Hardware Provider\log\installlog.txt.
Uninstall the Unity VSS provider,restart the Volume ShadowService and then re-install. Makesure that theUnitySnapshotProvider service issuccessfully installed.
4.2.1.9535982
922039 Cued Unity jobs can freeze when deleting Non-Recoverable Error LUN remote sessions.
Bring LUN resources back to anactive state and the deletion jobwill resume.
4.2.1.9535982
922448 In SMB file systems, when files are opened andread indicated access time does not change.
4.2.1.9535982
924945 When the Consistency Group properties page isselected for a specific consistency group, itdisplays incorrect values for the Snapshot UsedSpace for each LUN in the consistency groupunder the Snapshot(GB) column.
Use the UEMCLI to view theaccurate value of the SnapshotUsed Space for each LUN.
4.2.1.9535982
926382/930652/930654
After the initial license install on a new system,some features may not show as being enabledfrom in Unisphere even though the InitialConfiguration Wizard steps were completed.
Refresh the browser. 4.2.1.9535982
900886 After resetting the Unity system name, filereplication session system names are not updatedon Unisphere.
Revert the system name to theprevious name until the replicationsession completes.
4.2.1.9535982
Release Notes
Known issues 55
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
925993 When using a UEMCLI command to modifymultiple VDM import session settings, Unityreturns the following syntax error:
Operation failed. Error code:0x1000017 Command line parsing failednear "-targetResPool" token. There isa syntax error in the command. Pleaserecheck the command syntax. (ErrorCode:0x1000017)For example:
> uemcli -noHeader /import/session/nas -id import_181 set -productionIfPortPairsclient_interface:spb_eth2 -targetResPool pool_136 -namerename_6629 -targetImportIf if_198
When using UEMCLI command tomodify VDM properties onlymodify one VDM attribute at atime, or use the Unity REST APIor Unisphere change the settings.
4.2.1.9535982
906699 When four or more drives from the same drivepartner group (DPG) associated with a Unitystorage pool go end-of-life in less than 30 days, allof the drives are copied to spare drives at thesame time.
Ensure that only one drive iscopied at a time from the sameDPG of a storage pool to a sparedrive.
4.2.1.9535982
925452 When the HOME directory feature is enabled on aNAS file system (where clients connect to the filesystem using a HOME share name), clients canreceive errors if they open multiple sessions fromthe same host using different user names. Someapplications cache information based on sharename.
Clients should the user nameinstead of the HOME share namewhen connecting to file systemsthat use the HOME directoryfeature.
4.2.1.9535982
910384 Using an LACP bond on two or more of QLogicbased onboard CNA and Maelstrom SLIC ports,this can interrupt traffic and require an Ethernetdevice reset or Storage Processor reboot toresolve.
Do not use LACP bond devicesconfigured over the onboard CNAports or the Maelstrom SLICports until a fix is provided by theNIC device vendor.
4.2.1.9535982
923420 When configuring VMFS synchronous replicationsessions, if the Unity Storage Processorassociated with the VMFS operation reboots,Unity returns I/O errors.
Wait 1-2 minutes, then resumeI/O.
4.2.1.9535982
922673 When performing an Online Data-in-placehardware conversion, under rare circumstances,the Unisphere wizard message text incorrectlyadvises to replace the incorrect Storage Processor(SP) during the second SP swap. For example, ifyou replace SPA first, when it is time to replaceSPB, Unisphere may incorrectly advise to replaceSPA.
Do not replace an SP that hasalready been replaced - even ifthe migration wizard messageadvises to do so.
4.2.1.9535982
Release Notes
56 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
922568 During a SMB migration from a VNX system to aUnity system, the cut-over step in migration canfail if the HomeDirectory feature is enabled onsource system.
Do not try to attempt to modifyan access control list (ACL) onHome share when HomeDirectoryfeature is enabled on the VNXsystem.
4.2.1.9535982
922448 The SMB AccessTime parameter is not modifiedon files when they are opened and accessed inREAD mode.
None. 4.2.1.9535982
922294 Cannot delete a UFS64 file system. Reboot the associated StorageProcessor.
4.2.1.9535982
921214 Unity indicates that quota usage is larger than thespecified limit.
Change quota policy to "blocks". 4.2.1.9535982
913014 Unity can temporally return NoSpace errors whenthere is I/O to a LUN, even when there is stillspace remaining in the associated Storage Pool .
Resume I/O through the iSCSIclient.
4.2.1.9535982
920498 When file system and its associated Unity storagepool is full, it appears as if only read-only access isallowed to the file system. The file system isactually in a "full" state, and clients can transactI/O with the file system data.
The file system read-only is acritical failure, while the filesystem full is warning info. Movethe read-only priority higher thanfile system full.
4.2.1.9535982
920219 When trying to remove or export a share that is onthe destination side of an active replication session(this is prohibited), Unity returns the followingmessage: The specified operation couldnot be completed. Search for theerror code on the support website orproduct forums, or contact yourservice provider, if available.(Error Code:0x4)
Deleting a replicated NFS/SMBshare from a replicationdestination NAS server isprohibited. You cannot removeexport/share on destinationreplicated site, as this site is inread only
4.2.1.9535982
920076 If you enable replication on a NAS Server whose IPinterface is associated with a Fail Safe Network(FSN) port, a destination NAS server isautomatically created. However if there is nomatching FSN port on the destination system, theIP interface will not work after failover.
When setting up replication,ensure that link aggregation, FSNports, and Ethernet ports areavailable on the destinationsystem, and that the same LinuxDevice Name is used on both thesource and destination system.
4.2.1.9535982
919539 Thin-clone refresh operations can fail when aUnity system is under a heavy I/O or managementload, or when slow NL-SAS vault drives are used.
Retry the refresh several timesuntil it succeeds.
4.2.1.9535982
918130 When configuring a new SMB server on a NASserver, if you use any organization unit (OU) otherthan the default, clients cannot join to the domain,and Unity returns the following message: Thesystem encountered an unexpectederror.
Use the Unity UEMCLI toconfigure the SMB Server.
918130
Release Notes
Known issues 57
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
917502 The UEMCLI /stor/config/pool/fastvpstart command does not run successfully and
returns the following error message (therelocation task is actually not running): Exitcode: 1Output: Operation failed.Error code: 0x670016dThe relocationtask is already running for thestorage pool. Retry after the currenttask is complete. (Error Code:0x670016d)
Wait for the next FAST VPmetrics collection interval(approximately one hour afterrunning the UEMCLI command),and run the command again.
4.2.1.9535982
916949 Attempts to create a CIFS import session fail witherror message: Connection to a sourceCIFS server was lost(Error Code:0x900a324).
Verify that the source VNX importinterface and the destinationUnity import interface areconfigured with different IPaddresses.
4.2.1.9535982
916893 When creating a Fail-safe Network (FSN)configuration, a file system may becomeinaccessible. If you try to remove the file server,Unity returns the following NAS server statusmessage: "The specified NetworkInterface is currently used by NASserver services”.
Restart the Unity OS. Do notdelete an FSN configuration if it isused by active file interfaces.
4.2.1.9535982
916645 When FASTCache transitions to any state otherthan OK, when the issue is resolved Unity does not
return a message indicating that FASTCache isoperating normally again (even when theFASTCache health state returns to OK).
None. 4.2.1.9535982
915804 Because snapshots created with snapcli cannot beaccessed through Unisphere, the UEMCLI, orUnity REST API, Cloud Tier Appliances (CTA)cannot archive these snapshots.
None. 4.2.1.9535982
915550 When either Unity Storage Processor (SP) is inService Mode, ClouldIQ is unable to obtain metricsdata for the Unity system.
Resume the SP in Service Modeand it should resume normalstatus.
4.2.1.9535982
920691 When a Unity storage processor reboot occurswhile an asynchronous replication session is beingdeleted, the deletion job can hang even though thereplication session is actually deleted.
Reboot the Unity storageprocessor.
4.2.1.9535982
921511 Unisphere returns the following message: Yoursecurity session has expired. Youwill be redirected to the login page.
Confirm that the Unisphere loginaccount in use is still active hasStorage Admin privileges. Be sureto close the active browsersession before logging withanother account.
4.2.1.9535982
Release Notes
58 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
922018 Under particular conditions, Unisphere does notshow (or allow you to expand) a Unity storage poolwhen a pool is out of space.
Delete some resources that usethe storage pool in order to freeup storage space for the pool.
4.2.1.9535982
924719 A Unity OS upgrade process is interrupted, theUnity health check process indicates that thereare suspended jobs, and Unisphere/UEMCLIshows inconsistent information (Start/Finishtimes) about active jobs.
View Unity jobs with Unisphere/UEMCLI, and delete anyprocesses where the indicatedFinished time precedes the
Started time.
4.2.1.9535982
925555 When using the UEMCLI to view file import statusinformation with the /import/session showfunction, the indicated Source resource and
Target values are blank.
Use either Unisphere or theUEMCLI /import/session/nas command to view
status information for file importsessions.
4.2.1.9535982
926506 A file system recovery process is interrupted andUnity generates the following log information:begin_fs_recovery_internal:insertapiobj into Recovery list failed.
Rerun the recovery process and itshould resume.
4.2.1.9535982
911502 When using AppSync, if I/O is not stopped andwhile snap restore is in progress, the snap restoreoperation will fail. Another snap operation cannotbe started before resetting the previous snaprestore object after stopping I/O.
Quiesce the application runningon the production host and flushthe host cache to prevent datacorruption during the restore.Unmount the datastore using theUnity LUN from all ESX servers inthe ESX cluster, Windows server,or Linux server.If the primary LUN was stillreceiving IO and the snap restoreoperation failed, contact supportfor recovery.
4.2.0.9392909
914537 Consistency group back up operations to CTA aresupported only if all the member LUNs are of thesame size. Member LUNs with different sizes willbe supported in a future Unity release.
Refer to Knowledgebase article000501899 for more information.
4.2.0.9392909
892354 When FAST Cache is enabled on the storage poolfor a long time and the storage resources allocatedon the pool had been exposed to host I/O for along time and then FAST Cache is disabled on thepool, the operation completed successfully, butFAST Cache still appears as enabled on the pool.This is because the system is in the process offlushing data from FAST Cache to the drives,which can take time. When all data from FASTCache is moved to HDD media, FAST Cache willappear as disabled on that pool.
No workaround. 4.2.0.9392909
Release Notes
Known issues 59
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
892953 If a Flash drive is in a faulted state, it canpotentially produce invalid control information,which sometimes hits user interface and causes itto malfunctioning.
Remove the faulted drive fromthe DPE/DAE as soon as possibleto remedy the issue.
4.2.0.9392909
899530 An NFS-only NAS server cannot be created;Unisphere uploads a fake keytab file.
Create an NFS-only NAS serverand upload the keytab file. Then,after creating the server, uploadthe keytab file again. The correctfile will be uploaded on the secondattempt.
4.2.0.9392909
909842 A CIFS Migration session cannot be cut over if aNAS server exists on the destination with thesame name as migrated VDM.
Cancel the migration session.Remove the Unity NAS serverwith the same name as migratedVDM NAS server and try creatingthe migration session again.
4.2.0.9392909
910538 If the user creates a user Quota and tree Quota atthe same time, sometimes the user Quota creationfails. This happens in rare conditions, such aswhen trying to create a user quota and tree quotaconcurrently and iteratively hundreds of times.
Rerun the failed operation. 4.2.0.9392909
910856 Files and directories on sources system with noSecurity Descriptors (SD) or SD no DACL aremigrated with a an empty DACL instead of no SD.Since an empty DACL means no access, the enduser will experience access denied errors.
Manually reset the ACL of thosefiles and directories from aWindows client duringincremental copy or aftercommitting the migration.
4.2.0.9392909
911386 A second attempt to cutover an import session ofa VDM with a standalone CIFS server failed. Atfirst and second attempts user provided same newsource CIFS servers NETBIOS name. The audit logcontains messages similar to the following: Auditlog: Error 13157007777:VDM_Cifs_Jes1012 : Renaming LocalGroups database from COMPMIGJES1012to COMPMIGJES_10 failed with status'DuplicateEntry'.
Cleanup the source VNX with thatlocal group, retry the cutover,then manually restore the ACLs atthe destination. Alternatively,manually restore share ACLs onthe source before second cutoverattempt. (Remove an ACE whichdenies the host access to preventaccessing the source share aftercutover).
4.2.0.9392909
911403 A VDM from VNX was migrated to Unity 4.1.2.xusing IMT. When trying to configure replication forthis VDM from the Unity 4.1.2 source to a Unity4.2 destination, the replication configuration fails.An error message such as the following appears:Create replication session afterprovisioning destination FailedUnsupported argument is detected forthis task or operation (Error Code:0x9908)
Upgrade the Unity 4.1.2 system toUnity 4.2 and try to configurereplication for this VDM again.
4.2.0.9392909
Release Notes
60 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
911592 On the Unisphere Advance SMB shareproperty tab, it is specified in help the UMASKproperty can be modified only in Unix access rightmode, but in fact it could also be used in Nativemode.
The help is incorrect. The UMASKsetting can be set for Unix andNative mode.
4.2.0.9392909
911997 SMB and NFS share information may not beavailable in GUI or UEMCLI for a certain NASserver when this NAS server is in a faulted state asUnisphere management services were starting up.
Recover NAS server and thenrestart management software.
4.2.0.9392909
912115 For a NAS Server with multiprotocol enabled,when making changes on the NFS tab, applyingchanges will fail with an error if disabling/enablingSecure NFS. Other property changes will not besaved.
Reapply the changes withoutdisabling/enabling NFS secure.
4.2.0.9392909
892514 /911959
An asynchronous replication session or NDMPsession stopped progressing.
Manually restart the replicationsession by using pause andresume).
4.1.1.9138882 and later.
908756 Ongoing vMotion with a VMware NFS4 datastorecan fail after a storage processor reboot. This is aknown vSphere problem described in KB: https://kb.vmware.com/kb/2089321
No workaround. 4.2.0.9392909
911329 The file system size on a host decreased to 11Gfrom 19G after an asynchronous file replicationsession (where the source is a Thin file system inUnity 4.1.2 and the destination was a Thick filesystem in Unity 4.2).
Starting with the 4.2.x release,you cannot convert a file systemfrom thin to thick or thick to thin.Use the replication feature in theCLI to migrate a thick file systemto a thin file system or a thin filesystem to thick file system.
4.2.0.9392909
904622 If both SPs are abruptly shutdown/rebooted afterintegrated ESRS is configured, it is possible thatintegrated ESRS cannot be automatically re-enabled after an upgrade, and integrated ESRSstatus may become "unknown".
Using SSH, log in to the systemand run the following twocommands consecutively:
1. svc_esrs_ve -r2. svc_esrs_ve --reenable
4.2.0.9392909
904748 When there are a lot of NFSv4.1 clients(~50,000), the response time of the NFS servermay be very slow.
Reduce the number of NFSclients.
4.2.0.9392909
904946 While starting a LUN Move session on a LUN withsnapshot mount points (such as a LUN with a
populated Snap Hosts list), the following errormay display" Storage resource movesession move_XYZ encountered aninternal error. Please see the statusof LUN sv_123. After this occurs, the LUN that
Reboot the SP to align thesnapshot mount point and thesource LUN on the same SP.Either SP can be rebooted to dothis. To prevent the issue, do notstart any LUN Move sessions on aLUN with snapshot mount points.
4.2.0.9392909
Release Notes
Known issues 61
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
was being migrated may no longer be able toprocess IO requests.
905659 Integrated ESRS cannot be enabled successfullywhen a credentials-required SOCKS proxy server
is set up in Support Configuration > ProxyServer, unless the proxy server can provideservice when credentials are not provided.
No workaround. 4.2.0.9392909
905705 The /net/nas/is set command fails with the
following error message when -port is the only
argument: A required parameter ismissing from the CLI command. (ErrorCode:0x1000019) Otherwise, the command
completes successfully, but port is not modified.
No workaround. 4.2.0.9392909
905757 The VSS shadow import on a system with a lot ofdevices (approximately 35) might stop responding.Any devices above this is overflowing a 4KBbuffer. The Unity VSS Hardware provider log willshow the wmic command hanging.
No workaround. 4.2.0.9392909
905905 An error message appears when trying to modifyan IP interface on production side after failoverwhen the underlying destination Ethernet port forIP interface does not exist. The specifiedNetwork interface could not bemodified. A shutdown may have been inprogress causing the failure. (ErrorCode:0x67020f0)".
Delete the IP interface and re-create it .
4.2.0.9392909
906192 A file system appears offline and in an error stateduring incremental copy state. Import sessionremains in a healthy state, but the import progressstops.
Try to bring the file system backonline, or cancel the migration.
4.2.0.9392909
906249 A request to create a replication session forVMware NFS datastore which resides in amultiprotocol NAS server will fail until the firstsynchronization of the associated NAS serverreplication session.
Synchronize the NAS serverreplication session at least onceprior to creating a replicationsession for a VMware NFSdatastore residing in themultiprotocol NAS server.
4.2.0.9392909
906665 When a quota thread is updating the quota dataand the tree quota is deleted using the CLIcommand before the update is finished, sometimesthe delete tree quota operation fails with the errorThe tree quota object cannot befound.
Retry the delete quota operation. 4.2.0.9392909
906702 If a replication session name is modified, it appearsto complete successfully. However, the sessionname is not changed.
Wait for a while, the refresh thepage until the name appears asmodified.
4.2.0.9392909
Release Notes
62 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
906767 If the peer SP reboots right at the end of anotherwise successful upgrade, commands may failwith the following error The system isupgrading and is momentarily notavailable. Please try again later.(Error Code:0x600000e)
Contact your service provider. 4.2.0.9392909
906892 A replication session creation for a file system atsource array to destination array in the UnisphereGUI is successful. Then, deleting that replicationsession is also successful. However, when tryingto create a new replication session for the samefile system on the source array (of the previousreplication session) to the destination array, theoperation will fail with the error ReplicationInternal Error and rollback the creation. The
new replication session creation failure is expectedbecause the system does not allow two replicatedfile systems (one by the previous replication, theother by new replication) of the same source filesystem in the same destination VDM. The errormessage is not clear.
To create a new replicationsession for the same source filesystem used by a previousreplication session, delete thedestination file system of theprevious replication session in thesame destination VDM first.
4.2.0.9392909
907141 A dynamic pool shows that it is in degraded statefor several hours while the rebuilding of relatedmapped RAID has already completed. There is alow probability that this issue will occur whenMapped RAID goes from a BROKEN state to aREADY state after removing and reinserting drives(two or more for RAID1 and RAID5, or three ormore for RAID6), or if the enclosure goes offlineand online.
In most cases this issue willresolve itself several hoursautomatically, but the period ofdegraded state appears longerthan expected.
4.2.0.9392909
907158 After an upgrade to Unity 4.2, the ability to changethe SP owner is not available in Unisphere for NASservers.
Clear browser cookies to andrefresh Unisphere.
4.2.0.9392909
907186 If there is a checkpoint snapshot and it is createdbefore the last system reboot, and you want toback up the snapshot with NDMP, the backup willfail.
Create a copy of that snapshot,then run an NDMP backup for thecopy.
4.2.0.9392909
907269 Thin-cloned LUNs do not report LBPU, LBPWScapabilities and reject associated commands. Thin-cloned LUNs report provisioning type zero (neitherreserved nor thin in SCSI sense) in the same VPDregardless of the fact volume is thin by definition.
No workaround. 4.2.0.9392909
907311 On Window 7, a fully sparse file is always shown byWindows Explorer as a 1 KB file size on the disk.
This is a Win7 behavior, the 1KB isrepresenting the minimum clustersize. With Win10/W2K12, the fileon disk is now seen as 0.
4.2.0.9392909
Release Notes
Known issues 63
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
907314 When trying to create replication from Unity to aVNXe1600 in Unity Unisphere, no pool isrecommended on destination storage resourcewizard page.
Use the CLI to create a replicationsession from Unity to aVNXe1600.
4.2.0.9392909
908047 Time of last sync of the replication sessionbecomes "N/A" and the delta data is nottransferred from source side to destination side.
Pause and resume that replicationsession
4.2.0.9392909
908180 A NAS server creation operation takes a long timeduring a dynamic pool expansion operation.
Avoid creating a NAS server whenthe pool is being expanded.
4.2.0.9392909
908749 If the system is powered off (both SPs arepowered off at the same time) while a VDM localmove operation is ongoing, after array boots upthe VDM Local Move job may still not exit.
Workaround to this issue: 1) UseMluCli.exe poll -proc to find theVDM Local Move Object (startwith 0x2a) 2) Use MluCli.exeobjectops -b_careful -activate -oid <vdm local move oid> 3) Thejob will complete automaticallyonce the proc finishes. Willupdate this to a KB
4.2.0.9392909
908930 Even when snap auto delete is disabled on thestorage pool, the storage pool may still show adegraded state indicating it could not reach lowwater mark.
Use the CLI to increase the poolspace low water mark in order tobring the pool back to normalstate. For example:
uemcli -u xxx -p xxx /stor/config/pool -id pool_97 set -snapPoolFullLWM 40
4.2.0.9392909
909109 A failover with sync operation on a NAS serverreplication session may cause data to beunavailable for a long period when NAS server hasa file system replication session whose remainingsize is larger than 100MB.
Sync the file system replicationsessions before doing failoverwith sync on NAS serverreplication session.
4.2.0.9392909
909258 If the file system name and the VDM mount pointname are not the same, the name listed for the
Target File System during import sessioncreation is not correct.
Ensure the name of the target filesystem is the same value as theVDM mount point.
4.2.0.9392909
875485 The following error could be returned whenmultiple snap diff REST API requests were sent inparallel. { "error": { "created":"2016-12-05T17:34:36.533Z","errorCode": 131149826,"httpStatusCode": 503, "messages":[ { "en-US": "The system is busy. Tryagain later. If the problem persists,search for the error code on thesupport website or product forums, or
Reduce the number of paralleloperations, and try again.
All versions.
Release Notes
64 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
contact your service provider, ifavailable. (Error Code:0x7d13002)" } ] } }
883848 During certain read operations when the pool isfull, reads may hang causing timeout issue tooccur on the SP. If a pool is out of space and aLUN enters ReadOnly mode, it is possible for theSP to panic in some rare instances.
Free up space in the pool, orexpand the pool.
4.1.1.9138882 and later.
892673 /838496
When the user changes the name of a LUN whichis involved in a remote replication session, thereplication screens incorrectly display the oldname when the session is viewed from the remotesystem. The new name is correctly displayed forlocal replication sessions and in the replicationscreens of the sessions from the array that hoststhe renamed LUN.
The incorrect name does notimpact the replication session.Viewing the session from theremote system where therenamed LUN resides displays thecorrect name. Unisphere CLI canalso be used to locate the friendlyID of the source and destinationand then it can be mapped torenamed LUN.
4.0.1.8194551 andlater.
894343 Changing the system name is not reflected on theremote systems.
No workaround. 4.2.0.9392909
895535 When adding an IO limit policy to a LUN andpausing the IO limit policy at the same time, the IOlimit policy is not added to the conflictingoperations.
Add the IO limit policy to the LUNagain.
4.2.0.9392909
896339 When a replication source NAS Server has aProduction Network Interface on a port (or linkaggregation) which does not exist on thedestination, the IP will not be brought up aftersession failover unless the Network Interface Portis overridden on destination, since the systemcannot find a port with the specified name.
Before setting up replicationsessio,n pre-configure thedestination system to have amatching port name. Create a linkaggregation or insert matchingSLIC.
4.2.0.9392909
896350 In CloudIQ, the System metrics chart (like IOPS,Bandwidth, etc.) has missing values when VVolobjects are unbound and then re-bound. On theUnity Unisphere performance page, the datastoremetrics also have incorrect values when VVolobjects are unbound and re-bound.
No workaround required. AfterVVols has been bound, the issuewill resolve itself.
4.2.0.9392909
896446 When using SMB to import a VDM from a remotesystem, SMB2 clients may not be able to createsymlinks (a failure error of INVALID_PARAMETERdisplays).
After import completion, SMB2client symlink creation works asnormal.
4.2.0.9392909
897788 A failed snap restore operation error messagedisplays, and other snap operations cannot beperformed before reset the previous snap restoreobject after stopping IO.
No workaround. 4.2.0.9392909
Release Notes
Known issues 65
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
900541 When deleting many async replication sessions inone job, some sessions may fail to be deleted.
No workaround. 4.2.0.9392909
900792 LUN Move hangs. The session can still be cancelledsuccessfully or restarted after asingle reboot.
4.2.0.9392909
901617 The LUN Move will fail. Restart the LUN Move operation. 4.2.0.9392909
902479 A file system or LUN goes offline and remainsoffline for sometime when the pool becomes 100%full instead of going to read-only even after spaceis available in the pool.
Reboot the SP on which the FS isactive.
4.2.0.9392909
902538 When trying to create a thin clone in Unispherewhere there is no parent storage resource
snapshots created, in the first step of the CreateThin Clone wizard the system suggests to createa clone using an existing snapshot (but theexisting snapshot list is empty). Proceeding
through the wizard by clicking Next results in theerror To clone using existing eligblesnapshot, select snapshot.
When there are no existingsnapshots of the parent storageresource, manually select the
option clone using latestversion of resource.
4.2.0.9392909
903607 A bind VVol operation fails. Errors similar to thefollowing may display: The systemencountered an unexpected error.Search for the error code on thesupport website or product forums, orcontact your service provider, ifavailable. (Error Code:0x6702026)
Retry the bind VVol command. 4.1.2.9257522
903660 On the Consistency Groups page under Accesstab > Access details, hosts are displayed withtheir respective LUNS and associated HLUs.However, on the LUN page under host access, allof the HLUs are shown as zero.
No workaround. 4.1.1.9.9138882
903888 Occasionally, a communication error dialog will popup during an upgrade while one SP is rebooting.
The dialog is harmless and can beclosed.
4.2.0.9392909
904176 When modifying a CEPA Pool, the error messageThe specified Events Pool iscurrently locked by another requestappears.
Wait one minute beforeattempting to modify the poolagain.
4.2.0.9392909
904242 When expanding a dynamic pool by a drive countthat is less than the RAID width + 1, the progressindicator in the Unisphere GUI does not updateproperly to show incremental progress. Theprogress indicator will then show 100% when theexpansion is complete.
No workaround. The progressindicator will then show 100%when the expansion is complete.
4.2.0.9392909
Release Notes
66 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
904512 After migrating one VDM from VNX2 to Unitysuccessfully, another VDM could not be migrated.An error message similar to the following maydisplay: HTTPS connection Operationfailed. Error code: 0x9000194 Createsession fails with 1 error(s). Pleasecheck message by scpsysadmin@[email protected]:/home/sysadmin1/.migration/precheck_vdm_VDM_Cherry22.log. (ErrorCode:0x9000194) Job ID = N-551509:44:47 root@OB-d1234-spa spa:~> catlog3 Error: VDM_Cherry22: DNSserver(s) of ncc2k8.usd.lab.emc.comis(are) not reachable through thenetwork interface(s) not attached tothe VDM. After migration to Unity,the network interfaces attached tothe VDM will also get migrated. Otherclients of the Data Mover cannotconnect to the DNS server(s). Createanother network interface on the DataMover, and if applicable, correctroutes and VLAN functions, to makesure it can connect to the DNSserver(s). Warning: Cherry_move_FS2:Mount options: smbca will not bemigrated Warning: VDM_Cherry22:Domain Controller(s) ofncc2k8.usd.lab.emc.com is(are) notreachable through the networkinterface(s) not attached to the VDM.After migration to Unity, the networkinterfaces attached to the VDM willalso get migrated. Other clients ofthe Data Mover cannot connect to theDomain Controller(s). Create anothernetwork interface on the Data Moverto make sure it can connect to theDomain Controller(s).09:44:50root@OB-d1234-spa spa:
Rename the migration interface toa name not starting with nas_mig.
4.2.0.9392909
904746 A replication session with snapshot replicationenabled will go into an error state at the start of async (manual/auto) operation.
Pause and resume the replicationsession.
4.2.0.9392909
895052 SSH is disabled after a single-Storage ProcessorVSA upgrade.
After performing a Unity OEupgrade, re-enable SSH usingUnisphere or the followingUnisphere service command:svc_ssh -e.
All previous versions.
Release Notes
Known issues 67
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
895621 After an import session is cut over, the file importprocess does not appear to complete and remainsin a ready to commit state. The session cannot becancelled.
The import session appearscomplete after next StorageProcessor reboot.
4.1.0.8940590 andlater.
896002 If a Unity system uses NTP for synchronization,when the time is adjusted backwards, real-timesystem metrics do not appear and the systemgenerates Query ID not found(0x7d1400c)" errors.
In Unisphere, navigate to anotherpage and then return to themetrics page, or log out ofUnisphere and log in again.
4.1.0.8940590 andlater.
855767 When you customize a list of CIFS Shares AccessControl Entries (ACEs) by either making a RESTAPI call, editing the share permission using theWindows MMC console, or by using SMI-S API,isACEEnabled might erroneously indicate
false.
Ignore the valueisACEEnabled=false in this
case. When ACEs are properlyset, they are always enabled,despite this value in the REST APIattribute. A REST API request forlist of ACEs will return the correctlist of custom ACEs for the share,and those ACEs will all apply.Alternatively, force a reload of themanagement model for the shareby changing the sharedescription, or for the wholesystem by restarting themanagement software.
4.1.0.8940590 andlater.
871133 The progress of the incremental copy of VDMimport stops at 0% and does not progress.
Cancel, then restart the importoperation.
4.1.0.8940590 andlater.
792840(physicaldeployments only)
RecoverPoint and the native replication feature onthe storage system cannot simultaneously operateon the same volume or Fibre Channel (FC) port ofthe storage system. There is no such restriction onEthernet ports.
Run the /remote/sys show -detail command in the CLI
console of the storage system. Donot connect any RecoverPointappliances to the synchronous FCports on the storage system. Theports can also be viewed inUnisphere by going to
Unisphere > System >
System View > Enclosures.
All versions.
867849 Registering the Unity system with a secondvCenter with a different root certificate willdisable the registration with the first vCenter,making any virtual machines on the first vCenterinaccessible.
Unity only supports one vCenterconnection at a time. To changevCenters, unmount all data storesand unregister the VASA providerfrom the original vCenter beforeregistering the system as a VASAprovider for the new vCenter.
All versions.
863422 16Gb FC ports can have performance problemswhen using direct attach to certain 16Gb HBAs.
1. Connect using a 16Gb FCswitch.
All versions.
Release Notes
68 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
2. Use Microsoft Windowsdirect attach.
869166 When a host is configured to use CAVA for theCEPA server, there is a host IO error on SMBprotocol with the following message in the logs:Too many access from CAVA serverxx.xx.xx.xx without the EMCVirusChecking privilege:>>> Usercredential (xx.xx.xx.xx address ofthe host) .
Do not use CAVA/CEPA NASservers for regular host IO.
4.1.0.8940590 andlater.
864889 If an inter-version (4.0.x to 4.1.x) remotereplication session is created using Unisphere CLIand a NAS server owned by custom tenant ischosen as destination resource, the failover mightlead to loss of NAS connectivity.
When creating a remotereplication session, override theNAS server interface settings onthe destination array in order tobring VLAN ID assignment intocompliance with tenant settings.
4.1.0.8940590 andlater.
865864 A replication session may fail with a status code ofCritical Failure and health details indicatingThis replication session hasencountered an error. Try pausing,and then resuming the replicationsession. If the problem persists,delete, and then create thereplication session again. This issue can
occur when an array acting as a replicationdestination with NL-SAS drives in the first fourslots of enclosure 0 / bus 0 is under heavy loadduring a replication session update.
Try pausing, and then resumingthe replication session. If theproblem persists, delete, and thenrecreate the replication session.
4.1.0.8940590 andlater.
866692 When running the CLI /stor/prov/vmware/vmfs show -detail command, the
Compression percent reported is less than the
actual compression savings and is inaccurate.
The correct value for compressionpercent displays in the UnisphereUI.
4.1.0.8940590 andlater.
849914 The Job Details page in Unisphere does notdisplay the name of a LUN group after it failed tobe deleted.
There is no workaround for thisissue.
4.1.0.8940590 andlater.
850971 On the Host I/O Limit tab of the LUN propertieswindow where one system Host I/O limit is appliedto the LUN, the most recent polled times alwaysequal 0, even when switching the view, and afterleaving the page and coming back in.
There is no workaround for thisissue.
4.1.0.8940590 andlater.
862912 /834714
When changing the storage policy of a VVoldatastore, the operation may fail in vCenter.
Retry the operation. 4.0.1.8194551 andlater.
864758 A local replication session that is currently in asyncing state may not progress.
Pause, then resume thereplication session. If the issuepersists, reboot the system.
4.1.0.8940590 andlater.
Release Notes
Known issues 69
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
864815 If a thin file system is small or almost at-capacityand a snapshot is taken, the total allocated sizeand current allocation may appear larger than thefile system size.
There is no workaround for thisissue.
4.1.0.8940590 andlater.
864932 The LUN ID column was blank in the HostAccess table on the Properties window of aVMware datastore.
Navigate to Access > Hosts.Select the host and view the
LUNs tab of the Propertieswindow.
4.1.0.8940590 andlater.
862736 A VM running on a File VVol datastore mayintermittently go offline during VDM failback.
Restart the problematic VM invSphere/vCenter.
4.1.0.8940590 andlater.
784827 Some file system statistics may display very alarge value (for example, over100,000,000,000,000 KB/s of file systembandwidth) after a file system is internallyremounted.
There is no workaround for thisissue. The very large value is onlyfor a single point. The valuesbefore and after are correct.
All versions.
785823 When deploying a new virtual machine on a NASdatastore that was exported over NFSv4.1 withKerberos Security, the operation will fail with anAccess Denied message for the target data
store.
Disable Secure NFS for the NASserver.
4.1.0.8940590 andlater.
794943 /807302
While accessing Unisphere, users can expect up totwo pop-ups or warning screens. One is foraccepting the server certificate, and the other isfor providing a client certificate (instead ofcredentials) to connect to Unisphere. While theserver certificate warning should be accepted,
users should click Cancel in the pop-up thatsuggests connecting to Unisphere using a clientcertificate.
Note
(Mac users only) If a clientcertificate is accidentally chosenfor connecting to a UnisphereURL, users may see a blankscreen every time they try toaccess that URL. This can befixed by deleting the URL-to-client certificate mapping fromKeychain Access. Open Keychain
Access by browsing to Go >
Utilities in the Finder.
All versions.
802295 /830747
When a replication session is in an error state,pausing and resuming the session usually fixes theproblem. However, when the replicationdestination resource requires recovery, but thereplication source resource does not, pausing andresuming does not resolve the issue. The sessionwill still be in an error state and the destination filesystem will be offline.
Contact your service provider. All versions.
811020 When there are no datastores enabled for accessto a target ESXi host during replication, thestorage system iSCSI targets are not registered onthe target ESXi server. When the Storage
Manually configure iSCSI targetdiscovery of the storage systemsiSCSI addresses on the ESXihosts.
All versions.
Release Notes
70 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Table 2 Known issues (continued)
Issuenumber
Problem description Workaround / Resolution Exists in version
Replication Adapter (SRA) requests that thestorage system enable Snaps-Only access to thetarget ESXi server, the operation succeeds, butrescan does not discover the snapshots.
811431 The replication session state may be reported asunknown after performing a failback operation.
Pause and resume the replicationoperation to recover the session.
All versions.
817821 If a dashboard is created and a language pack isapplied, the titles for the widgets are nottranslated.
Re-create the dashboard afterthe language pack is applied.
4.1.0.8940590 andlater.
821501 When a user runs a token-based incrementalbackup using Networker, a full backup isperformed instead.
Add ATTEMPT_TBB=Y toApplication Informationwhile configuring the NDMPclient, or change the value in theNDMP client properties.
4.0.1.8194551 andlater.
835021 Recovery using Site Recovery Manager (SRM)fails intermittently. After session failover, thedatastore is eventually mounted correctly, even ifa failure is reported.
Wait some time and retry theoperation.
4.0.1.8194551 and later
840613 When an SP is in service mode, the power supplyof the DPE appears as faulted.
When the SP returns from servicemode, the correct status of thepower supply is displayed.
All versions.
UnityVSA-only known issuesThe following issues affect only the UnityVSA (virtual deployments). Issues affectingall Unity systems are in Table 2 on page 53.
Table 3 UnityVSA-only known issues
Issuenumber
Problem description Workaround /Resolution Exists in version
778326 When creating a pool using virtual disks, the Nextbutton remains dimmed after selecting a tier for avirtual disk.
Click elsewhere within the wizardwindow to trigger selectionvalidation.
All versions.
801368 /802226
The storage system restarts unexpectedly with amonitor timeout or software watchdog timeout.This occurs when the system and user data sharethe same datastores (physical disks) and thesystem is overloaded with aggressive I/Oworkloads.
For example, a system can become overloadedwhen the workload includes heavy sequential writeblock I/O mixed with random file read and writeI/O.
It is recommended that userstorage be on a separate datastore than the system data storewhere UnityVSA is deployed. Ifthat is not possible, ensure thatthere are no more than fourvirtual disks on the system datastore. If user data is allocated onthe system data store, it can bemigrated to a different data store.See the vSphere documentationfor details. For UnityVSA
All versions.
Release Notes
Known issues 71
Table 3 UnityVSA-only known issues (continued)
Issuenumber
Problem description Workaround /Resolution Exists in version
deployment considerations, seethe UnityVSA Installation Guide.
809371 When configuring a NAS server for replication froma Unity system to a UnityVSA system, the user canchoose a storage processor on the destination,although UnityVSA has only one storage processor(SP A). Choosing SP B and continuing to createthe session results in an error.
Choose SP A when replicating toa UnityVSA system.
All versions.
830522 When a virtual disk is added or removed while apool is simultaneously being destroyed, one ormore virtual disks that had been part of that poolmay report: This virtual disk faileddue to a system or IO error.
Start a rescan using UnisphereCLI command uemcli /env/disk rescan, REST API, or
Unisphere.
4.0.1.8194551 andlater.
LimitationsLearn about limitations in Unity.
Limitation First affected release Limitation lifted
VMware vSphere 6.5 is notcurrently supported on theUnityVSA.
4.1.0.8940590 4.2.0.9392909
When setting I/O limit policies,observe the following restrictions:
l For a shared KBPS I/O limitpolicy, set the limit to be atleast 2048 KBPS.
l For a non-shared KBPS I/Olimit policy, set the limit to beat least 1024 KBPS.
l The IOPS I/O limit policy'sminimum is 100 IOPS.
4.0.0.7329527 Still in effect.
The current Unity VVolimplementation has not yet beenfully certified for use with VMwareHorizon View. Although it maywork, it is recommended that youdo not deploy VDI desktops usingUnity VVol datastores. Supportand issue resolution will not beavailable for this integration.
4.0.0.7329527 Still in effect.
Release Notes
72 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Environment and system requirementsIn order for the Unity system to function properly, ensure that your environmentmeets these minimal requirements.
Support matrixRefer to the Unity Support Matrix on the support website for compatibility andinteroperability information.
Screen sizeThe minimum resolution for using the Unisphere GUI is 1024 x 768 pixels. Smallerscreens may be able to display the GUI in full screen mode.
ESRS VE and DHCPDynamic IP addresses (DHCP) cannot be used for any EMC Secure Remote ServicesVirtual Edition (ESRS VE) component (ESRS VE servers, Policy Manager, or manageddevices). You must assign static IP addresses to those devices that you plan to havemanaged by ESRS VE.
Unity Hybrid and All Flash support both the Centralized and Integrated versions ofESRS VE. UnityVSA supports the Centralized version of ESRS VE only. Moreinformation about the ESRS VE is available in the EMC Unity Secure Remote ServicesRequirements and Configuration document.
Note
If the system automatically assigns a dynamic IP address to any ESRS VE component,you must change it to a static IP address. Also, leases for the IP addresses that EMCdevices use cannot be set to expire.
Software media, organization and filesLearn about software media, organization, and files required for your system.
Required updateIt is recommended that you keep your Unity Family system up to date by upgrading tothe latest software version at your earliest opportunity.
Problems downloading this releaseIf you have difficulty downloading this release using Microsoft Internet Explorerversion 7, try using a newer version of Microsoft Internet Explorer, Google Chrome, orMozilla Firefox version 4 or greater.
Obtaining and installing product licenses during initial configurationBefore you create storage, you must install product and feature licenses on yoursystem.
Before you begin
Note
This process is different for UnityVSA Community Edition systems. For instructions onhow to obtain and activate a license for your UnityVSA Community Edition system,see the Obtaining a License for UnityVSA Community Edition post on the EMCCommunity Network at: https://community.emc.com/community/products/unity.
Release Notes
Environment and system requirements 73
l Register your product. This provides you instant access to easy-to-use tools toplan, install, maintain, and service your product. It also entitles you to softwareupdates, installation tools, and more.
l Ensure that you have the following:
n License authorization code (LAC)—The LAC is sent by email from EMC.
n The system serial number (physical systems) or the system UUID (virtualsystems).
Procedure
1. On the Unisphere Licenses page of the Initial Configuration wizard, select GetLicense Online.
2. Follow the instructions on the licensing website and download the license filelocally.
Note
Do not change the name of the license file.
3. Select Install License and use Chose File to browse to the license file youdownloaded locally.
4. Select Open.
The Results page will confirm the license was successfully installed.
Obtaining and installing additional product licensesAfter obtaining product licenses for initial configuration, follow these steps to obtainand install additional product licenses.
Procedure
1. In Unisphere, select the Settings icon, and then select Software andLicenses > License Information.
2. Select a product license from the list to display a description of that license.
3. To obtain a product license, select Get License Online.
a. Use the link that is provided in the LAC email or access the product page onthe support website, and download the license file locally.
Note
Do not change the name of the license file.
b. Transfer the license file to a computer that has access to the storagesystem, or connect the computer you used to obtain the license file to thesame subnet of the storage system.
4. To upload a product license, select Install License.
a. Review the Software License and Maintenance Agreement and selectAccept license agreement.
b. Locate the license file, select it, and select Open to install the license file onthe storage system.
Results
The license file is installed on the storage system.
Release Notes
74 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
For sites with restricted internet access, or for more information about obtaining thelicense, go to the Unity Info Hub at http://bit.ly/unityinfohub.
Installing and enabling language packsInstall and enable language packs to change the language of the GUI.
Before you begin
Review the considerations included in Software Media, Organization, and Files.
Procedure
1. In Unisphere, select the Settings icon, and then select Software andLicenses > Language Packs
2. Select Obtain Language Pack Online and enter your EMC Support credentialswhen prompted.
3. Download the appropriate language pack file to your local system.
4. Return to Unisphere and select Install Language Pack to launch the InstallLanguage Pack wizard.
5. Select the language pack file you want to upload.
6. Select Upload.
The language pack is uploaded and installed on the system, and the Resultswindow can be closed.
7. Enable the language pack on your system:
a. In Unisphere, select the My Account icon and select Preferences.
b. Select the preferred language from the Language list.
c. Select OK.
The language pack is enabled.
Unique identifier for UnityVSA
For UnityVSA, use the License Activation Key instead of the serial number or UUID asthe unique identifier for setting up EMC Secure Remote Services (ESRS) and forobtaining customer support (professional editions).
New and enhanced feature details
Link aggregation (physical deployments only)The storage system provides network high availability or redundancy by using linkaggregation. With link aggregation, there can be two to four Ethernet portcombinations in one logical link. Each storage processor (SP) must have the sametype and number of Ethernet ports. The loss of a network connection does not initiatefailover to the peer SP, avoiding an outage. The switch automatically moves traffic tothe remaining ports in the link aggregation if the path to one port fails. When theyconnection is restored, the switch adds the failed port back to the link aggregationgroup and resumes use of the port. You can aggregate ports that are on the same IOmodule, different IO modules, or you can aggregate IO module and onboard Ethernetports together (such as the onboard 10GbE BaseT port with the 10GbE Optical CNA
Release Notes
Installing and enabling language packs 75
ports). Link aggregation also allows the system to load-balance host traffic, providingbetter performance.
Ports must have the same MTU size in order to be aggregated. Linked ports mustconnect to the same logical switch, and the switch must be configured to use the IEEE802.3ad standard Link Aggregation Control Protocol (LACP). Link Aggregation shouldalso be configured at the host level to provide resiliency against port or cable failures.Depending on the vendor, this may also be referred to as trunking, bonding, or NICteaming. Refer to your switch vendor's documentation for more information aboutusing LACP.
Note
Link aggregation can only be used for NAS server, file replication, and file importinterfaces; you cannot aggregate Ethernet ports that have iSCSI configured.
Link aggregation has the following advantages:
l High availability of network paths to and from the storage system — If onephysical port of an aggregated port fails, the system does not lose connectivity.
l Possible increased overall throughput — This is because multiple physical portsare bonded into one logical port.
l Load balancing across linked ports — Network traffic is distributed betweenmultiple physical ports.
Create a link aggregationAggregate two or more ports together for high availability.
Before you begin
Ports must have the same MTU size in order to be aggregated. Linked ports mustconnect to the same logical switch, and the switch must be configured to use the IEEE802.3ad standard Link Aggregation Control Protocol (LACP).
Note
Link aggregation can only be used for NAS server, file replication, and file importinterfaces; you cannot aggregate Ethernet ports that have iSCSI configured.
Procedure
1. Under Settings, select Access > High Availability
2. Under Link aggregations, select the Add icon.
3. Select the ethernet ports you want to add to the link aggregation.
Change a link aggregationAdd or remove ports from a link aggregation.
Before you begin
You cannot edit a link aggregation that is already part of a fail safe network (FSN).You must first remove that link aggregation from the FSN in order to do so. Youcannot remove the master/primary port from a link aggregation. You cannot add aport to the link aggregation that is already independently part of an FSN.
Ports must have the same MTU size in order to be aggregated. Linked ports mustconnect to the same logical switch, and the switch must be configured to use the IEEE802.3ad standard Link Aggregation Control Protocol (LACP).
Release Notes
76 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Procedure
1. Under Settings, select Acess > High Availability.
2. Under Link aggregations, select an existing link aggregation and click the Editicon.
a. Select a non-primary port and click the Delete icon to remove it from thelink aggregation.
Note
Removing a port from a link aggregation with only two ports will destroy thelink aggregation.
b. Alternatively, click the Add icon and select a new port to add to the linkaggregation.
c. Optionally, change the MTU size for the link aggregation (changes all portsat once).
3. Click Apply after each change before you make another modification.
Fail-safe networkingLearn about Fail-safe networking (FSN).
A Fail-Safe Network (FSN) is a high-availability feature that extends link failover intothe network by providing switch-level redundancy. An FSN appears as a single linkwith a single MAC address and potentially multiple IP addresses. An FSN can be aport, a link aggregation, or any combination of the two. An FSN adds an extra layer ofavailability to link aggregations alone. Link aggregations provide availability in theevent of a port failure. FSNs provide availability in the event of a switch failure. Eachport or link aggregation is considered as a single connection. Only one connection inan FSN is active at a time. All the connections making up the FSN share a singlehardware (MAC) address.
If the system detects a failure of the active connection, it will automatically switch tothe standby connection in the FSN. That new connection assumes the networkidentity of the failed connection, until the primary connection is available again. Youcan designate which connection is the primary port/connection. To ensureconnectivity in the event of a hardware failure, create FSN devices on multiple I/Omodules or onboard ports. The FSN components are connected to different switches.If the network switch for the active connection fails, the FSN fails over to aconnection using a different switch, thus extending link failover out into the network.
When replicating from one Unity system to another, configure the FSN the same wayon both systems as a best practice. You will need to manually configure the FSN onthe destination before setting up replication. Otherwise, if you set up the FSN on thedestination after replication is configured, you will need to use the Override addressoption to select the FSN as the interface for the destination NAS server.
Note
A NAS server IP interface should be build on the highest level logical device. If youwant to repurpose a port or link aggregation currently used as a NAS server IPinterface for an FSN, you will need to remove the IP interface from the NAS server,create the FSN, and reassign the IP interface to the FSN device.
Release Notes
Fail-safe networking 77
Create a fail-safe networkLearn how to create a fail-safe network.
Before you begin
If you want to add a link aggregation to this FSN, be sure to create that linkaggregation first.
FSN provides additional protection and redundancy over link aggregation by providinghigh availability in the event of a switch failure.
Procedure
1. Under Settings, select Access > High Availability
2. Under Fail Safe Networking, click the Add icon.
3. Select two or more ports to add to the Fail Safe Network. You can choosestandalone ports or link aggregations, or any combination of the two.
4. Select the Primary Port for the FSN and click Apply.
Change an FSNLearn how to add or remove links to an existing fail-safe network.
Before you begin
You cannot remove a primary port from an FSN.
Procedure
1. Under Settings, select Acess > High Availability.
2. Under Fail Safe Networking, select the FSN for which you want to add orremove ports or link aggregations and click the Edit icon.
3. Select a non-primary port and click the Delete icon to remove it from the FSN.Alternatively, click the Add icon and select a new port or link aggregation to addto the FSN. Click Apply after each add or delete change before you makeanother modification.
Repurpose a NAS ethernet port for FSN or link aggregation
Before you begin
Note
If you only have one interface currently set up for your NAS server, the hostconnection will experience downtime during this repurpose process.
If you have already dedicated an ethernet port as an interface for a NAS server, butwould like to repurpose it for fail-safe networking (FSN) or link aggregation (LA), youwill need to deconstruct the network port, assign it to a LA or FSN, and then build theNAS server on top of the new FSN device.
Procedure
1. Remove the IP interface from the NAS server for the port you would like to usein the FSN.
2. Optionally, create the Link Aggregation to be included in the FSN.
3. Create an FSN using the desired ports and/or link aggregations.
Release Notes
78 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
4. Recreate the IP interface for the NAS server on top of the FSN device.
Manage Fail-safe networkingLearn about Fail-safe networking (FSN) and which attributes are used to manage FSNin the CLI.
A Fail-Safe Network (FSN) is a high-availability feature that extends link failover intothe network by providing switch-level redundancy. An FSN appears as a single linkwith a single MAC address and potentially multiple IP addresses. An FSN can be aport, a link aggregation, or any combination of the two. An FSN adds an extra layer ofavailability to link aggregations alone. Link aggregations provide availability in theevent of a port failure. FSNs provide availability in the event of a switch failure. Eachport or link aggregation is considered as a single connection. Only one connection inan FSN is active at a time. All the connections making up the FSN share a singlehardware (MAC) address.
If the system detects a failure of the active connection, it will automatically switch tothe standby connection in the FSN. That new connection assumes the networkidentity of the failed connection, until the primary connection is available again. Youcan designate which connection is the primary port/connection. To ensureconnectivity in the event of a hardware failure, create FSN devices on multiple I/Omodules or onboard ports. The FSN components are connected to different switches.If the network switch for the active connection fails, the FSN fails over to aconnection using a different switch, thus extending link failover out into the network.
When replicating from one Unity system to another, configure the FSN the same wayon both systems as a best practice. You will need to manually configure the FSN onthe destination before setting up replication. Otherwise, if you set up the FSN on thedestination after replication is configured, you will need to use the override option toselect the FSN as the interface for the destination NAS server.
Note
A NAS server IP interface should be build on the highest level logical device. If youwant to repurpose a port or link aggregation currently used as a NAS server IPinterface for an FSN, you will need to remove the IP interface from the NAS server,create the FSN, and reassign the IP interface to the FSN device.
Table 4 FSN attributes
Attribute Description
ID ID of the Fail-Safe Networking port.
SP Storage processor the FSN is on.
MTU size Maximum Transmission Unit (MTU) size.
Linux device name Name of the Linux network device.
Primary port ID of the primary port used in the FSN. Theprimary port cannot be removed.
Secondary ports Comma-separated list of the other secondaryports in the FSN. This includes both linkaggregations and ethernet ports.
Active port ID of the active port for the FSN.
Release Notes
Manage Fail-safe networking 79
Table 4 FSN attributes (continued)
Attribute Description
Health state The health state of the FSN. Valid values are:
l OK (5) — The FSN is operating
normally, or the active port of the FSNhas changed.
l Degraded/Warning (10) —
Performance of the FSN has degraded.
l Minor failure (15) — An FSN port
link is down.
l Major failure (20) — An FSN port
is missing ports, or an FSN port is notsymmetrical.
Health details Detailed health information for the FSN.
Create an FSNUse the CLI to create a fail-safe network.
Create a fail-safe network using two or more ports or link aggregations.
Format/net/fsn create -primaryPort <value> -secondaryPorts <value> [-mtuSize <value>]Action qualifier
Qualifier Description
-primaryPort Type the ID of the primary port for the FSN. This can be either anethernet port or link aggregation.
-secondaryPorts Type the comma-separated list of additional port or link aggregationIDs to be included in the FSN.
-mtuSize Optionally, type the Minimum Transmission Unit size for the FSN. TheMTU must be in the range allowed for all of the ports included in theFSN. The default value is 1500.
ExampleThe following example creates an FSN where the primary port is a single ethernetport, and the secondary ports include a link aggregation and additional single ethernetport.
uemcli -d 10.0.0.1 -u Local/joe -p MyPassword456! /net/fsn create -primaryPort spa_eth0 -secondaryPorts "spa_la_2,spa_eth3"
Storage system address: 10.0.0.1Storage system port: 443HTTPS connection
ID = spa_fsn_0ID = spb_fsn_0
Release Notes
80 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
Operation completed successfully.
View FSN settingsReview the list and details of each FSN on the system.
Format/net/fsn [-id <value>] showObject qualifier
Qualifier Description
-id Type the ID for the FSN port for which you would like to view details.Do not specify to see details for all FSNs on the system.
ExampleThe following example shows the details of all the FSNs on the system.
uemcli -d 10.0.0.1 -u Local/joe -p MyPassword456! /net/fsn show -detail
Storage system address: 10.0.0.1Storage system port: 443HTTPS connection
1: ID = spa_fsn_0_1 SP = spa Primary port = spa_iom_0_eth1 Secondary ports = spa_la_2 Active port = spa_iom_0_eth1 MTU size = 1500 Available MTU sizes = 1500,9000 Health state = OK (5) Health details = "FSN port is operating normally."
2: ID = spb_fsn_0_1 SP = spb Primary port = spb_iom_0_eth1 Secondary ports = spb_la_2 Active port = spb_iom_0_eth1 MTU size = 1500 Available MTU sizes = 1500,9000 Health state = OK (5) Health details = "FSN port is operating normally."
Change an FSNMake changes to an existing FSN.
Change a fail-safe network by modifying the included secondary ports or MTU sizes.
Format/net/fsn -id <value> set [-secondaryPorts <value>] [-mtuSize<value>]Object qualifier
Qualifier Description
-id Type the ID of the FSN port.
Release Notes
Manage Fail-safe networking 81
Action qualifier
Qualifier Description
-secondaryPorts Type the list of full IDs of the physical ports and/or link aggregationports for the FSN. Remove any from the list you wanted deleted fromthe FSN, and add any you want included.
-mtuSize Type the new Minimum Transmission Unit (MTU) size for the FSN.
Example 1The following example changes the MTU size of the FSN "spa_fsn_0".
uemcli -d 10.0.0.1 -u Local/joe -p MyPassword456! /net/fsn -dspa_fsn_0 set -mtuSize 9000
Storage system address: 10.0.0.1Storage system port: 443HTTPS connection
ID = spa_fsn_0ID = spb_fsn_0
Operation completed successfully.
Example 2The following example shows an attempt to add Ethernet port "spa_iom_0_eth2" toFSN "spa_fsn_0", however this ethernet port is already in use for another linkaggregation and could not be added independently to the FSN.
uemcli -d 10.0.0.1 -u Local/joe -p MyPassword456! /net/fsn -dspa_fsn_0 set -secondaryPorts spa_iom_0_eth2
Storage system address: 10.0.0.1Storage system port: 443HTTPS connection
Operation failed. Error code: 0x6000851One of the specified ports cannot be used to configure an FSN because to it is already included in an FSN or link aggregation. (Error Code:0x6000851)
Delete an FSNDelete an FSN from the system.
Create a fail-safe network using two or more ports or link aggregations.
Format/net/fsn -id <value> deleteObject qualifier
Qualifier Description
-id Type the ID of the FSN port.
ExampleThe following example deletes FSN "spa_fsn_0"
Release Notes
82 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes
uemcli -d 10.0.0.1 -u Local/joe -p MyPassword456! /net/fsn -idspa_fsn_0 delete
Storage system address: 10.0.0.1Storage system port: 443HTTPS connection
ID = spa_fsn_0ID = spb_fsn_0
Operation completed successfully.
Additional resourcesAs part of an improvement effort, revisions of the software and hardware areperiodically released. Therefore, some functions described in this document might notbe supported by all versions of the software or hardware currently in use. This productrelease notes document provides the most up-to-date information on productfeatures. Contact your technical support professional if a product does not functionproperly or does not function as described in this document.
Where to get helpSupport, product, and licensing information can be obtained as follows:
Product informationFor product and feature documentation or release notes, go to Unity TechnicalDocumentation at: www.emc.com/en-us/documentation/unity-family.htm.
TroubleshootingFor information about products, software updates, licensing, and service, go to OnlineSupport (registration required) at: https://Support.EMC.com. After logging in, locatethe appropriate Support by Product page.
Technical supportFor technical support and service requests, go to Online Support at: https://Support.EMC.com. After logging in, locate Create a service request. To open aservice request, you must have a valid support agreement. Contact your SalesRepresentative for details about obtaining a valid support agreement or to answer anyquestions about your account.
AdvisoriesFor information on an individual technical or security advisory, go to the OnlineSupport website and search using the ESA number or “EMC Security Advisories” asthe keyword. For a list of ESAs in the current year, refer to EMC Security Advisories –All EMC Products – Current Year. For a list of older ESAs, refer to EMC SecurityAdvisories All EMC Products – Archive.
Set up the “My Advisory Alerts” option to receive alerts for EMC Technical Advisories(ETAs) and EMC Security Advisories (ESAs), to stay informed of critical issues, andprevent potential impact to your environment. Go to Account Settings andPreferences, type the name of an individual product, click to select it from the list,and then click Add Alert. For the individual product or All EMC Products, selectETA’s and/or ESA’s.
UnityVSA supportUsers of the UnityVSA Community Edition can find community-provided supportresources at the Unity product community on the Community Network at: https://community.emc.com/community/products/unity.
Release Notes
Additional resources 83
Copyright © 2016-2017 Dell, Inc. and its subsidiaries. All rights reserved.
Published October 2017
Dell believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS-IS.“ DELL MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH
RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBED IN THIS PUBLICATION
REQUIRES AN APPLICABLE SOFTWARE LICENSE.
Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners.
Published in the USA.
Release Notes
84 Unity All Flash, Unity Hybrid, UnityVSA 4.2.1.9535982 Release Notes