Report No.: ATE20190903 Page 1 of 59 Shenzhen Accurate Technology Co., Ltd. Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com EMC TEST REPORT for Shenzhen Qianhai Patuoxun Network&Technology Co., Ltd. Projection Alarm Clock Model No.: HM433A, YGH3200, GEHM433ABJP, GEHM433ABUK, GEHM433ABEU, GEHM433ABUS Prepared for : Shenzhen Qianhai Patuoxun Network&Technology Co., Ltd. Address : Wuhe RD 49#, Bantian District B-202, 6th Building Shenzhen Guangdong CN Prepared by : Shenzhen Accurate Technology Co., Ltd. Address : 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: +86-755-26503290 Fax: +86-755-26503396 Report No. : ATE20190803 Date of Test : June 04, 2019--June 14, 2019 Date of Report : June 17, 2019

Upload: others

Post on 08-Nov-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 1 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

EMC TEST REPORT

for Shenzhen Qianhai Patuoxun Network&Technology Co., Ltd.

Projection Alarm Clock

Model No.: HM433A, YGH3200, GEHM433ABJP,

GEHM433ABUK, GEHM433ABEU, GEHM433ABUS

Prepared for : Shenzhen Qianhai Patuoxun Network&Technology Co., Ltd. Address : Wuhe RD 49#, Bantian District B-202, 6th Building

Shenzhen Guangdong CN

Prepared by : Shenzhen Accurate Technology Co., Ltd. Address : 1/F., Building A, Changyuan New Material Port, Science &

Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396

Report No. : ATE20190803 Date of Test : June 04, 2019--June 14, 2019 Date of Report : June 17, 2019

Page 2: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 2 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

TABLE OF CONTENT Description Page

Test Report Declaration 1. TEST RESULTS SUMMARY ................................................................................................... 7

2. GENERAL INFORMATION ...................................................................................................... 8 2.1. Description of Device (EUT) .......................................................................................................... 8 2.2. Special Accessory and Auxiliary Equipment ............................................................................... 8 2.3. Description of Test mode ................................................................................................................ 9 2.4. Classification of apparatus ............................................................................................................. 9 2.5. Model difference declaration .......................................................................................................... 9 2.6. Description of Test Facility ........................................................................................................... 10 2.7. Measurement Uncertainty ............................................................................................................ 10

3. MEASURING DEVICE AND TEST EQUIPMENT .............................................................. 11 3.1. For Power Line Conducted Emission ......................................................................................... 11 3.2. For Disturbance Power Measurement ........................................................................................ 12 3.3. For Radiated Emission Measurement ........................................................................................ 12 3.4. For Electrical Fast Transient /Burst Immunity Test .................................................................. 13 3.5. For Surge Immunity Test .............................................................................................................. 13 3.6. For Electrostatic Discharge Immunity Test ................................................................................ 13 3.7. For Injected Current Susceptibility Test ..................................................................................... 14 3.8. For Continuous RF electromagnetic field disturbances Test .................................................. 14 3.9. For Voltage Dips and Interruptions Test .................................................................................... 14

4. POWER LINE CONDUCTED EMISSION MEASUREMENT ............................................ 15 4.1. Block Diagram of Test Setup ....................................................................................................... 15 4.2. Measuring Standard ...................................................................................................................... 15 4.3. Power Line Conducted Emission Limits (Class B) ................................................................... 15 4.4. EUT Configuration on Measurement .......................................................................................... 15 4.5. Operating Condition of EUT ......................................................................................................... 16 4.6. Test Procedure ............................................................................................................................... 16 4.7. Measuring Results ......................................................................................................................... 16

5. DISTURBANCE POWER MEASUREMENT ....................................................................... 19 5.1. Block Diagram of Test ................................................................................................................... 19 5.2. Measuring Standard ...................................................................................................................... 19 5.3. Radiated Emission Limits(Class B) ............................................................................................. 19 5.4. Operating Condition of EUT ......................................................................................................... 20 5.5. Test Procedure ............................................................................................................................... 20 5.6. Measuring Results ......................................................................................................................... 20

6. RADIATED EMISSION MEASUREMENT ........................................................................... 22 6.1. Block Diagram of Test Setup ....................................................................................................... 22 6.2. Measuring Standard ...................................................................................................................... 22 6.3. Radiated Emission Limits ............................................................................................................. 22 6.4. Test Procedure ............................................................................................................................... 23 6.5. Measuring Results ......................................................................................................................... 23

7. CLICKS TEST .......................................................................................................................... 24 7.1. Clicks Test Standard and limit ..................................................................................................... 24 7.2. Test Result ...................................................................................................................................... 24

8. HARMONIC CURRENT EMISSION MEASUREMENT ..................................................... 25 8.1. Block Diagram of Test Setup ....................................................................................................... 25

Page 3: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 3 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

8.2. Measuring Standard ...................................................................................................................... 25 8.3. Measuring Results ......................................................................................................................... 25

9. VOLTAGE FLUCTUATION AND FLICKER MEASUREMENT ....................................... 29 9.1. Block Diagram of Test Setup ....................................................................................................... 29 9.2. Measuring Standard ...................................................................................................................... 29 9.3. Measuring Results ......................................................................................................................... 29

10. ELECTROSTATIC DISCHARGE IMMUNITY TEST ...................................................... 31 10.1. Block Diagram of Test Setup ....................................................................................................... 31 10.2. Test Standard ................................................................................................................................. 31 10.3. Severity Levels and Performance Criterion ............................................................................... 31 10.4. Operating Condition of EUT ......................................................................................................... 32 10.5. Test Procedure ............................................................................................................................... 32 10.6. Test Results .................................................................................................................................... 32

11. RF FIELD STRENGTH SUSCEPTIBILITY TEST .......................................................... 34 11.1. Block Diagram of Test ................................................................................................................... 34 11.2. Test Standard ................................................................................................................................. 34 11.3. Severity Levels and Performance Criterion ............................................................................... 35 11.4. Operating Condition of EUT ......................................................................................................... 35 11.5. Test Procedure ............................................................................................................................... 35 11.6. Test Results .................................................................................................................................... 35

12. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST ..................................... 37 12.1. Block Diagram of Test Setup ....................................................................................................... 37 12.2. Test Standard ................................................................................................................................. 37 12.3. Severity Levels and Performance Criterion ............................................................................... 37 12.4. Operating Condition of EUT ......................................................................................................... 38 12.5. Test Procedure ............................................................................................................................... 38 12.6. Test Result ...................................................................................................................................... 38

13. SURGE IMMUNITY TEST .................................................................................................. 40 13.1. Block Diagram of Test Setup ....................................................................................................... 40 13.2. Test Standard ................................................................................................................................. 40 13.3. Severity Levels and Performance Criterion ............................................................................... 40 13.4. Operating Condition of EUT ......................................................................................................... 41 13.5. Test Procedure ............................................................................................................................... 41 13.6. Test Result ...................................................................................................................................... 41

14. INJECTED CURRENTS SUSCEPTIBILITY TEST ......................................................... 43 14.1. Block Diagram of Test Setup ....................................................................................................... 43 14.2. Test Standard ................................................................................................................................. 43 14.3. Severity Levels and Performance Criterion ............................................................................... 43 14.4. Operating Condition of EUT ......................................................................................................... 44 14.5. Test Procedure ............................................................................................................................... 44 14.6. Test Results .................................................................................................................................... 44

15. VOLTAGE DIPS AND INTERRUPTIONS TEST ............................................................ 46 15.1. Block Diagram of Test Setup ....................................................................................................... 46 15.2. Test Standard ................................................................................................................................. 46 15.3. Severity Levels and Performance Criterion ............................................................................... 46 15.4. Operating Condition of EUT ......................................................................................................... 47 15.5. Test Procedure ............................................................................................................................... 47 15.6. Test Result ...................................................................................................................................... 47

16. TEST PHOTOGRAPHS ...................................................................................................... 49 16.1. Photo of Conducted Emission Measurement ............................................................................ 49 16.2. Photo of Disturbance Power Test ............................................................................................... 49

Page 4: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 4 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

16.3. Photograph of set-up for Radiated susceptibility ...................................................................... 50 16.4. Photo of Electrostatic Discharge Immunity Measurement ...................................................... 50 16.5. Photo of Electrical Fast Transient /Burst Test ........................................................................... 51 16.6. Photo of Surge and Voltage Dips and Interruption Immunity Test ......................................... 51 16.7. Photo of Injected Current Susceptibility Test ............................................................................ 52 16.8. Photo of flicker Test ....................................................................................................................... 52

17. PHOTOGRAPHS OF THE EUT ........................................................................................ 53

Page 5: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 5 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Test Report Declaration Applicant : Shenzhen Qianhai Patuoxun Network&Technology Co., Ltd.

Address : Wuhe RD 49#, Bantian District B-202, 6th Building

Shenzhen Guangdong CN

Manufacturer : Shenzhen YuanGuangHao Electronics Co., Ltd.

Address : NO.7, LianYi Street, TankKeng Road, HengGang Town, Shenzhen, P.R. China

Product : Projection Alarm Clock

Model No. : HM433A, YGH3200, GEHM433ABJP,

GEHM433ABUK, GEHM433ABEU, GEHM433ABUS

Trade name : n.a.

Measurement Procedure Used: EN 55014-1: 2017 EN 61000-3-2: 2014 EN 61000-3-3: 2013 EN 55014-2: 2015 (IEC 61000-4-2: 2008

IEC 61000-4-3: 2006 +A1:2007 +A2:2010 IEC 61000-4-4: 2012 IEC 61000-4-5: 2014 IEC 61000-4-6: 2013 IEC 61000-4-11: 2004)

The device described above is tested by Shenzhen Accurate Technology Co., Ltd. to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Shenzhen Accurate Technology Co., Ltd. is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the EN55014-1, EN61000-3-2, EN61000-3-3 and EN55014-2 requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen Accurate Technology Co., Ltd.

Page 6: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 6 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Date of Test : June 04, 2019--June 14, 2019 Date of Report : June 17, 2019

Prepared by :

(Tim.zhang, Engineer)

Approved & Authorized Signer :

( Sean Liu, Manager)

Page 7: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 7 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

1. TEST RESULTS SUMMARY

Test Items Test Standard Test Results

Power Line Conducted Emission EN 55014-1: 2017 Pass

Disturbance Power EN 55014-1: 2017 Pass

Click EN 55014-1: 2017 N/A

Radiated Emission EN 55014-1: 2017 N/A

Harmonic Current EN 61000-3-2: 2014 Pass

Voltage Fluctuation and Flicker EN 61000-3-3: 2013 Pass

Electrostatic Discharge Immunity EN 55014-2: 2015 (IEC61000-4-2: 2008)

Pass

Electrical Fast Transients/Bursts Immunity EN 55014-2: 2015 (IEC61000-4-4: 2012)

Pass

Radiated frequency electromagnetic Field

EN 55014-2: 2015 (IEC61000-4-3: 2006 +A1:2007 +A2:2010)

Pass

Surge Immunity EN 55014-2: 2015 (IEC61000-4-5:2014)

Pass

Injected Current Susceptibility Test EN 55014-2: 2015 (IEC61000-4-6: 2013)

Pass

Voltage dips and interruptions Immunity EN 55014-2: 2015 (IEC61000-4-11:2004)

Pass

Remark: “N/A” means “Not applicable”.

Page 8: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 8 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

2. GENERAL INFORMATION

2.1.Description of Device (EUT)

Product : Projection Alarm Clock

Model No. : HM433A, YGH3200, GEHM433ABJP,

GEHM433ABUK, GEHM433ABEU, GEHM433ABUS

Rating : DC 5V (Powered by charge port)

Trade Name : N/A Applicant : Shenzhen Qianhai Patuoxun Network&Technology Co., Ltd.Address : Wuhe RD 49#, Bantian District B-202, 6th Building

Shenzhen Guangdong CN

Manufacturer : Shenzhen YuanGuangHao Electronics Co., Ltd. Address : NO.7, LianYi Street, TankKeng Road, HengGang Town,

Shenzhen, P.R. China.

Date of sample received

: June 01, 2019

Date of Test : June 04, 2019--June 14, 2019

Sample Number : 1900644

2.2.Special Accessory and Auxiliary Equipment

FM Generator (provided by laboratory)

: Manufacturer: Rohde & Schwarz Model: SML01 S/N: 101161

AC/DC Power Adapter (provided by laboratory)

: Model: MX12X6-0502000VU INPUT: 100-240V~50/60Hz 0.5A OUTPUT:5V/1.5A

Load

Page 9: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 9 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

2.3.Description of Test mode

Test mode: ON(Projection&Clock display&FM ON&USB output)

2.4.Classification of apparatus

Category I: apparatus containing no electronic control circuitry.

Category II: transformer toys, dual supply toys, mains powered motor operated appliances, tools, heating appliances and similar electric apparatus (for example – UV radiators, IR radiators and microwave ovens) containing electronic control circuitry with no clock frequency higher than 15MHz. Category III: equipment which in normal use, is not connected to a power network and has no cables attached. This category includes apparatus provided with rechargeable batteries, solar or other similar d.c. power sources which can be charged or operated by connecting the apparatus to the mains power. However, this apparatus shall also be tested as an apparatus in category II while it is connected to the mains network. Category IV: all other apparatus covered by the scope of this standard. The EUT belongs to Category IV equipment. According to the section 7.2.4 of the standard EN 55014-2, Category IV apparatus shall fulfill the following requirements: – electrostatic discharge with performance criterion B (5.1); – fast transients with performance criterion B (5.2); – injected currents up to 80 MHz with performance criterion A (5.4); – radiofrequency electromagnetic fields with performance criterion A (5.5) – surges with performance criterion B (5.6); – voltage dips with performance criterion C (5.7).

2.5.Model difference declaration

HM433A, YGH3200, GEHM433ABJP, GEHM433ABUK, GEHM433ABEU, GEHM433ABUS are identical in interior structure, electrical circuits and components, and just model number is different for the marketing requirement.

Page 10: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 10 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

2.6.Description of Test Facility

EMC Lab : Recognition of accreditation by Federal Communications Commission (FCC) The Designation Number is CN1189 The Registration Number is 708358 Listed by Innovation, Science and Economic Development Canada (ISEDC) The Registration Number is 5077A-2 Accredited by China National Accreditation Service for Conformity Assessment (CNAS) The Registration Number is CNAS L3193 Accredited by American Association for Laboratory Accreditation (A2LA) The Certificate Number is 4297.01

Name of Firm : Shenzhen Accurate Technology Co., Ltd Site Location : 1/F., Building A, Changyuan New Material Port, Science &

Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Subcontracted Items

: RF Field Strength Susceptibility Test

Subcontractor : Shenzhen Academy of Metrology and Quality Inspection Site Location : Bldg. of Shenzhen Academy of Metrology and Quality

Inspection, Longzhu Road, Nanshan, Shenzhen, China

2.7.Measurement Uncertainty

Conducted Emission Expanded Uncertainty = 2.72dB, k=2 (Mains ports, 9kHz-30MHz)

Radiated emission expanded uncertainty (9kHz-30MHz)

= 2.66dB, k=2

Radiated emission expanded uncertainty (30MHz-1000MHz)

= 4.28dB, k=2

Radiated emission expanded uncertainty (1G-18GHz)

= 4.98dB, k=2

Radiated emission expanded uncertainty (18G-26.5GHz)

= 5.06dB, k=2

Page 11: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 11 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

3. MEASURING DEVICE AND TEST EQUIPMENT

3.1.For Power Line Conducted Emission

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval

1. Test Receiver Rohde & Schwarz ESCS30 100307 Jan.05, 2019 1 Year 2. Test Receiver Rohde & Schwarz ESPI 100396/003 Jan.05, 2019 1 Year 3. Test Receiver Rohde & Schwarz ESPI 101526/003 Jan.05, 2019 1 Year 4. Test Receiver Rohde & Schwarz ESR 101817 Jan.05, 2019 1 Year 5. L.I.S.N. Schwarzbeck NLSK8126 8126431 Jan.05, 2019 1 Year 6. L.I.S.N. Rohde & Schwarz ESH3-Z5 100305 Jan.05, 2019 1 Year 7. L.I.S.N. Rohde & Schwarz ESH3-Z5 100310 Jan.05, 2019 1 Year 8. L.I.S.N. Rohde & Schwarz ESH3-Z6 100132 Jan.05, 2019 1 Year 9. L.I.S.N. Rohde & Schwarz ESH3-Z6 100979 Jan.05, 2019 1 Year

10. Pulse Limiter Rohde & Schwarz ESH3-Z2 100305 Jan.05, 2019 1 Year 11. Pulse Limiter Rohde & Schwarz ESH3-Z2 100312 Jan.05, 2019 1 Year 12. Pulse Limiter Rohde & Schwarz ESH3-Z2 100815 Jan.05, 2019 1 Year

13. 50Ω Coaxial Switch

Anritsu Corp MP59B 6200283936

Jan.05, 2019 1 Year

14. 50Ω Coaxial Switch

Anritsu Corp MP59B 6200283933

Jan.05, 2019 1 Year

15. 50Ω Coaxial Switch

Anritsu Corp MP59B 6200506474

Jan.05, 2019 1 Year

16. VOLTAGE PROBE

Schwarzbeck TK9416 N/A Jan.05, 2019 1 Year

17. RF CURRENT PROBE

Rohde & Schwarz EZ-17 100048 Jan.05, 2019 1 Year

18.

8-Wire Impedance Stabilisation Network

Schwarzbeck CAT5 8158

8158-0035 Jan.05, 2019 1 Year

19. RF Coaxial Cable

SUHNER N-2m No.2 Jan.05, 2019 1 Year

20. RF Coaxial Cable

SUHNER N-2m No.3 Jan.05, 2019 1 Year

21. RF Coaxial Cable

SUHNER N-2m No.14 Jan.05, 2019 1 Year

Page 12: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 12 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

3.2.For Disturbance Power Measurement

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval

1. Test Receiver Rohde & Schwarz ESCS30 100307 Jan.05, 2019 1 Year 2. Test Receiver Rohde & Schwarz ESPI 100396/003 Jan.05, 2019 1 Year 3. Test Receiver Rohde & Schwarz ESPI 101526/003 Jan.05, 2019 1 Year 4. Test Receiver Rohde & Schwarz ESR 101817 Jan.05, 2019 1 Year 5. Absorbing Clamp Rohde & Schwarz MDS21 100142 Jan.05, 2019 1 Year 6. Absorbing Clamp Rohde & Schwarz MDS21 100136 Jan.05, 2019 1 Year 7. 50Ω Coaxial Switch Anritsu Corp MP59B 6200283933 Jan.05, 2019 1 Year 8. 50Ω Coaxial Switch Anritsu Corp MP59B 6200283936 Jan.05, 2019 1 Year 9. RF Coaxial Cable JING CHENG N-6m No.4 Jan.05, 2019 1 Year 10. RF Coaxial Cable JING CHENG N-6m No.5 Jan.05, 2019 1 Year

3.3.For Radiated Emission Measurement

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval

1. Spectrum Analyzer Agilent E7405A MY45115511 Jan.05, 2019 1 Year 2. Spectrum Analyzer Rohde&Schwarz FSV40 101495 Jan.05, 2019 1 Year 3. Test Receiver Rohde&Schwarz ESCS30 100307 Jan.05, 2019 1 Year 4. Test Receiver Rohde& Schwarz ESPI 100396/003 Jan.05, 2019 1 Year 5. Test Receiver Rohde& Schwarz ESPI 101526/003 Jan.05, 2019 1 Year 6. Test Receiver Rohde& Schwarz ESR 101817 Jan.05, 2019 1 Year 7. Bilog Antenna Schwarzbeck VULB9163 9163-194 Jan.05, 2019 1 Year 8. Bilog Antenna Schwarzbeck VULB9163 9163-323 Jan.05, 2019 1 Year 9. Log.-Per.Antenna Schwarzbeck VUSLP

9111B 9111B-074 Jan.05, 2019 1 Year

10. Biconical Broad Band Antenna

Schwarzbeck VHBB 9124+BBA 9106

9124-617 Jan.05, 2019 1 Year

11. Loop Antenna Schwarzbeck FMZB1516 1516131 Jan.05, 2019 1 Year 12. Horn Antenna Schwarzbeck BBHA9120D 9120D-655 Jan.05, 2019 1 Year 13. Horn Antenna Schwarzbeck BBHA9120D 9120D-1067 Jan.05, 2019 1 Year 14. Vertical Active

Monopole AntennaSchwarzbeck VAMP 9243 9243-370 Jan.05, 2019 1 Year

15. RF Switching Unit+PreAMP

Compliance Direction

RSU-M2 38322 Jan.05, 2019 1 Year

16. Pre-Amplifier Agilent 8447D 294A10619 Jan.05, 2019 1 Year 17. Pre-Amplifier Rohde&Schwarz CBLU11835

40-01 3791 Jan.05, 2019 1 Year

18. 50 Coaxial Switch Anritsu Corp MP59B 6200237248 Jan.05, 2019 1 Year 19. 50 Coaxial Switch Anritsu Corp MP59B 6200506474 Jan.05, 2019 1 Year 20. RF Coaxial Cable Schwarzbeck N-5m No.1 Jan.05, 2019 1 Year 21. RF Coaxial Cable Schwarzbeck N-1m No.6 Jan.05, 2019 1 Year

Page 13: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 13 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

22. RF Coaxial Cable Schwarzbeck N-1m No.7 Jan.05, 2019 1 Year 23. RF Coaxial Cable SUHNER N-3m No.8 Jan.05, 2019 1 Year 24. RF Coaxial Cable RESENBERGER N-3.5m No.9 Jan.05, 2019 1 Year 25. RF Coaxial Cable SUHNER N-6m No.10 Jan.05, 2019 1 Year 26. RF Coaxial Cable RESENBERGER N-12m No.11 Jan.05, 2019 1 Year 27. RF Coaxial Cable RESENBERGER N-0.5m No.12 Jan.05, 2019 1 Year 28. RF Coaxial Cable SUHNER N-2m No.13 Jan.05, 2019 1 Year 29. RF Coaxial Cable SUHNER N-0.5m No.15 Jan.05, 2019 1 Year 30. RF Coaxial Cable SUHNER N-2m No.16 Jan.05, 2019 1 Year 31. RF Coaxial Cable RESENBERGER N-6m No.17 Jan.05, 2019 1 Year

3.4.For Electrical Fast Transient /Burst Immunity Test

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval

1. ULTRA COMPACT SIMULATOR

EM TEST UCS 500 N5

V0928104968 Jan.05, 2019 1Year

2. CAPACITIVE CLAMP

EM TEST HFK 0509-34 Jan.05, 2019 1Year

3. EMCPRO SYSTEM (IMMUNITY TESTER)

THERMO EMC PRO Plus-BASE

1108237 Jan.05, 2019 1Year

3.5.For Surge Immunity Test

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval

1. ULTRA COMPACT SIMULATOR

EM TEST UCS 500 N5

V0928104968 Jan.05, 2019 1Year

2. EMCPRO SYSTEM (IMMUNITY TESTER)

THERMO EMC PRO Plus-BASE

1108237 Jan.05, 2019 1Year

3. COUPLER DECOUPLER FOR TELECOM LINES

THERMO CM-TEL-CD 0403273 Jan.05, 2019 1Year

3.6.For Electrostatic Discharge Immunity Test

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval1. ESD Generator TESEQ NSG 437 823 Jan. 07, 2019 1 Year

Page 14: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 14 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

3.7.For Injected Current Susceptibility Test

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval

1. Conducted Immunity Test System

FRANKONIA CIT-10 126B1121 Jan.05, 2019 1Year

2. CDN FRANKONIA CDN-M2/3 A3027020 Jan.05, 2019 1Year 3. EM Injection

Clamp FCC F-203I-23mm 091824 Jan.05, 2019 1Year

4. 6dB Attenuator Weinschel WA59-6-33 A329 Jan.05, 2019 1Year

3.8.For Continuous RF electromagnetic field disturbances Test

Item Equipment Manufacturer Model No. Eqpt No. Last Cal. Cal. Interval

1. Signal Generator

Rohde &Schwarz

SMB100A SB9422/02 Jul.02, 2018 1 Year

2. Signal Generator

Rohde &Schwarz

SMF100A SB8501/03 Apr.23, 2019 1 Year

3. Voltage Meter

Rohde &Schwarz

URV5-Z2 SB9422/03 Apr.23, 2019 1 Year

4. Voltage Meter

Rohde &Schwarz

URV5-Z2 SB9422/04 Apr.23, 2019 1 Year

5. Power Probe

Rohde &Schwarz

NRP-Z81 SB9422/06 Apr.14, 2019 1 Year

6. Power Probe

Rohde &Schwarz

NRP-Z81 SB9422/07 Apr.14, 2019 1 Year

7. Power Meter

Rohde &Schwarz

NRP SB9422/05 Apr.14, 2019 1 Year

8. Power Amplifier

PRANA MT310A

SB9422/08Mar.27, 2019 1 Year

9. Broadband Antenna

Rohde &Schwarz

HL046E

SB9422/13Mar.27, 2019 1 Year

10. Horn Antenna AR ATH800M5GA SB9422/15 Mar.27, 2019 1 Year 11.

Power Amplifier MILMEGA A-001

SB9422/10

Mar.27, 2019 1 Year

12. Power Meter

Rohde &Schwarz

NRVD SB3437 Jul.02, 2018 1 Year

3.9.For Voltage Dips and Interruptions Test

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval

1. ULTRA COMPACT SIMULATOR

EM TEST UCS 500 N5

V0928104968 Jan. 05, 2019 1Year

Page 15: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 15 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

4. POWER LINE CONDUCTED EMISSION MEASUREMENT

4.1.Block Diagram of Test Setup

(EUT: Projection Alarm Clock)

4.2.Measuring Standard

EN 55014-1: 2017

4.3.Power Line Conducted Emission Limits (Class B)

Frequency (MHz)

Limit dB(V) Quasi-peak Level Average Level

0.15 - 0.50 66.0 - 56.0 * 56.0 - 46.0 * 0.50 - 5.00 56.0 46.0 5.00 - 30.00 60.0 50.0

NOTE1-The lower limit shall apply at the transition frequencies. NOTE2-The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to 0.50MHz.

4.4.EUT Configuration on Measurement

The following equipments are installed on Conducted Emission Measurement to meet EN55014–1 requirements and operating in a manner, which tends to maximize its emission characteristics in a normal application.

4.4.1. Projection Alarm Clock (EUT)

Model Number : HM433A

Serial Number : 1900644

Manufacturer : Shenzhen YuanGuangHao Electronics Co., Ltd.

L.I.S.N

Test ReceiverAC Mains

Adapter EUT

Page 16: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 16 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

4.5.Operating Condition of EUT

4.5.1. Setup the EUT as shown on Section 4.1.

4.5.2. Turn on the power of all equipments.

4.5.3. Let the EUT work in test mode then measure it.

4.6.Test Procedure

The EUT is put on the plane 0.8m high above the ground by insulating support and connected to the AC mains through Line Impedance Stability Network (L.I.S.N). This provided a 50ohm coupling impedance for the tested equipments. Both sides of AC line are investigated to find out the maximum conducted emission according to the EN55014 regulations during conducted emission measurement. The bandwidth of the field strength meter (R&S Test Receiver ESCS30) is set at 9kHz in 150kHz-30MHz and 200Hz in 9kHz-150kHz. The frequency range from 150kHz to 30MHz is investigated for AC mains.

4.7.Measuring Results

PASS. The frequency range 150 kHz to 30MHz is investigated.

Note: Emissions attenuated more than 20 dB below the permissible value are not reported.

The spectral diagrams are shown in the following pages.

Page 17: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 17 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Page 18: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 18 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Page 19: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 19 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

5. DISTURBANCE POWER MEASUREMENT

5.1.Block Diagram of Test

5.1.1.Block diagram of connection between the EUT and simulators

Clamp

(EUT: Projection Alarm Clock)

5.2.Measuring Standard

EN 55014-1: 2017

5.3.Radiated Emission Limits(Class B)

5.3.1. Disturbance power limits for the frequency range 30 MHz to 300 MHz

Frequency

MHz

Limits dB(pW) Quasi-peak Value Average Value

30 - 300 45 Increasing Linearly with Frequency to 55

(QP)

35 Increasing Linearly with Frequency to 45

(AV) (Table a)

5.3.2. Margin when performing disturbance power measurement in the frequency range 200MHz to300MHz

Frequency MHz

Limits dB(pW) Quasi-peak Value Average Value

200 - 300 0 Increasing Linearly with Frequency to 10

(QP)

- (AV)

Note: The measured result at a particular frequency shall be less than the relevant limit minus the corresponding margin (at that frequency)

(Table b)

AC Mains

EUT

Test Receiver

Page 20: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 20 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

5.4.Operating Condition of EUT

5.4.1. Setup the EUT as shown on Section 5.1.

5.4.2. Turn on the power of all equipments.

5.4.3. Let the EUT work in test mode then measure it.

5.5.Test Procedure

The EUT is placed on the plane 0.8m high above the ground by insulating support and away from other metallic surface at least 0.4m. It is connected to the power mains through an extension cord of 6m min. The absorber clamp clamps the cord and moves from the far end to the EUT to measure the disturbing energy emitted from the cord. The bandwidth of the test receiver (R&S ESCS30) is set at 120KHz.

5.6.Measuring Results

PASS. The frequency range from 30MHz to 300MHz is investigated. Note: Emissions attenuated more than 20 dB below the permissible value are not reported. The spectral diagrams are shown in the following pages. Remark: All emission readings from the equipment under test are lower than the applicable limits (Table a) reduced by the margin (Table b)

Page 21: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 21 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Page 22: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 22 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

6. RADIATED EMISSION MEASUREMENT

6.1.Block Diagram of Test Setup

6.1.1.Block diagram of test setup (In chamber)

6.2.Measuring Standard

EN 55014-1: 2017

6.3.Radiated Emission Limits

Frequency Distance Field Strengths Limit (MHz) (Meters) dB(V/m)

30—230 3 40 230—1000 3 47

Note: (1) The smaller limit shall apply at the combination point between two frequency bands.

(2) Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the EUT.

Antenna Elevation Varies From 1 to 4 Meters

3 Meters

EUT and Simulators System

0.8 Meter

GROUND PLANE

Page 23: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 23 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

6.4.Test Procedure

The EUT is placed on a turntable, which is 0.8 meter high above the ground. The turntable can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna, which is mounted on an antenna tower. The antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level. Bilog antenna (calibrated by Dipole Antenna) is used as a receiving antenna. Both horizontal and vertical polarizations of the antenna are set on test. The bandwidth of the Receiver (ESCS30) is set at 120kHz.

6.5.Measuring Results

N/A.

6.5.1.Mains operated appliances

The EUT shall be also deemed to comply with the requirement of this standard in the frequency range from 300 MHz to 1 000 MHz without further testing if both conditions 1) and 2) below are fulfilled:

1). the disturbance power emission from the EUT is lower than the limits of Table 7 reduced by the values of Table 8; 2). the maximum clock frequency is less than 30 MHz After testing and evaluation, the product meets both requirements, so the radiation of this mode does not need to be tested.

6.5.2.Battery operated appliances

The EUT shall comply with the limits in Table 9 for the frequency range from 30 MHz to 1 000 MHz (see also Figure 5).

Note: Battery power is not supported, so this test is not required.

Page 24: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 24 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

7. CLICKS TEST

7.1.Clicks Test Standard and limit

7.1.1.Test Standard

EN 55014-1: 2017

7.1.2.Test Limit

According to standard EN 55014-1, if click rate (N) less 5/min and the time of this discontinuous disturbance does not exceed 10ms, then the limit values are omitted.

7.2.Test Result

n.a

Page 25: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 25 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

8. HARMONIC CURRENT EMISSION MEASUREMENT

8.1.Block Diagram of Test Setup

(EUT: Projection Alarm Clock)

8.2.Measuring Standard

EN 61000-3-2: 2014 (Class A)

8.3.Measuring Results

Result: pass

PC

AC Power Source

AC Mains

Test analyzer Adapter EUT

Page 26: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 26 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Harmonics – Class-A per Ed. 4.0 (2014)(Run time)

EUT: Projection Alarm Clock M/N:HM433A Tested by: Frank Test category: Class-A per Ed. 4.0 (2014) (European limits) Test Margin: 100 Test date: 2019/6/14 Start time: 17:33:16 End time: 17:35:57 Test duration (min): 2.5 Data file name: H-000412.cts_data Comment: ON Report NO.:ATE20190803 Customer: Shenzhen YuanGuangHao Electronics Co., Ltd. Test Result: Pass Source qualification: Normal Current & voltage waveforms

-0.6

-0.4

-0.2

0.0

0.2

0.4

0.6

-300

-200

-100

0

100

200

300

Cu

rre

nt (A

mp

s)

Vo

ltag

e (V

olts)

Harmonics and Class A limit line European Limits

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

Cu

rre

nt R

MS

(Am

ps)

Harmonic #4 8 12 16 20 24 28 32 36 40

Test result: Pass Worst harmonics H15-3.7% of 150% limit, H15-5.4% of 100% limit

Page 27: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 27 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Current Test Result Summary (Run time)

EUT: Projection Alarm Clock M/N:HM433A Tested by: Frank Test category: Class-A per Ed. 4.0 (2014) (European limits) Test Margin: 100 Test date: 2019/6/14 Start time: 17:33:16 End time: 17:35:57 Test duration (min): 2.5 Data file name: H-000412.cts_data Comment: ON Report NO.:ATE20190803 Customer: Shenzhen YuanGuangHao Electronics Co., Ltd. Test Result: Pass Source qualification: Normal THC(A): 0.055 I-THD(%): 173.7 POHC(A): 0.009 POHC Limit(A): 0.251 Highest parameter values during test:

V_RMS (Volts): 230.00 Frequency(Hz): 50.00 I_Peak (Amps): 0.334 I_RMS (Amps): 0.067 I_Fund (Amps): 0.032 Crest Factor: 5.160 Power (Watts): 7.2 Power Factor: 0.484

Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.001 1.080 N/A 0.001 1.620 N/A Pass 3 0.030 2.300 1.3 0.031 3.450 0.9 Pass 4 0.001 0.430 N/A 0.001 0.645 N/A Pass 5 0.027 1.140 2.4 0.027 1.710 1.6 Pass 6 0.001 0.300 N/A 0.001 0.450 N/A Pass 7 0.023 0.770 3.0 0.023 1.155 2.0 Pass 8 0.000 0.230 N/A 0.001 0.345 N/A Pass 9 0.019 0.400 4.8 0.019 0.600 3.2 Pass 10 0.000 0.184 N/A 0.001 0.276 N/A Pass 11 0.015 0.330 4.5 0.015 0.495 3.1 Pass 12 0.000 0.153 N/A 0.001 0.230 N/A Pass 13 0.011 0.210 5.3 0.011 0.315 3.6 Pass 14 0.000 0.131 N/A 0.000 0.197 N/A Pass 15 0.008 0.150 5.4 0.008 0.225 3.7 Pass 16 0.000 0.115 N/A 0.000 0.173 N/A Pass 17 0.006 0.132 4.7 0.006 0.198 3.2 Pass 18 0.000 0.102 N/A 0.000 0.153 N/A Pass 19 0.005 0.118 4.4 0.005 0.178 3.0 Pass 20 0.000 0.092 N/A 0.000 0.138 N/A Pass 21 0.005 0.107 N/A 0.005 0.161 N/A Pass 22 0.000 0.084 N/A 0.000 0.125 N/A Pass 23 0.004 0.098 N/A 0.004 0.147 N/A Pass 24 0.000 0.077 N/A 0.000 0.115 N/A Pass 25 0.004 0.090 N/A 0.004 0.135 N/A Pass 26 0.000 0.071 N/A 0.000 0.107 N/A Pass 27 0.003 0.083 N/A 0.003 0.125 N/A Pass 28 0.000 0.066 N/A 0.000 0.099 N/A Pass 29 0.002 0.078 N/A 0.002 0.116 N/A Pass 30 0.000 0.061 N/A 0.000 0.092 N/A Pass 31 0.002 0.073 N/A 0.002 0.109 N/A Pass 32 0.000 0.058 N/A 0.000 0.086 N/A Pass 33 0.002 0.068 N/A 0.002 0.102 N/A Pass 34 0.000 0.054 N/A 0.000 0.081 N/A Pass 35 0.002 0.064 N/A 0.002 0.096 N/A Pass 36 0.000 0.051 N/A 0.000 0.077 N/A Pass 37 0.001 0.061 N/A 0.001 0.091 N/A Pass 38 0.000 0.048 N/A 0.000 0.073 N/A Pass 39 0.001 0.058 N/A 0.001 0.087 N/A Pass 40 0.000 0.046 N/A 0.000 0.069 N/A Pass

Page 28: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 28 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Voltage Source Verification Data (Run time)

EUT: Projection Alarm Clock M/N:HM433A Tested by: Frank Test category: Class-A per Ed. 4.0 (2014) (European limits) Test Margin: 100 Test date: 2019/6/14 Start time: 17:33:16 End time: 17:35:57 Test duration (min): 2.5 Data file name: H-000412.cts_data Comment: ON Report NO.:ATE20190803 Customer: Shenzhen YuanGuangHao Electronics Co., Ltd. Test Result: Pass Source qualification: Normal Highest parameter values during test:

Voltage (Vrms): 230.00 Frequency(Hz): 50.00 I_Peak (Amps): 0.334 I_RMS (Amps): 0.067 I_Fund (Amps): 0.032 Crest Factor: 5.160 Power (Watts): 7.2 Power Factor: 0.484

Harm# Harmonics V-rms Limit V-rms % of Limit Status 2 0.155 0.460 33.72 OK 3 0.584 2.069 28.24 OK 4 0.101 0.460 21.89 OK 5 0.081 0.920 8.84 OK 6 0.103 0.460 22.35 OK 7 0.051 0.690 7.42 OK 8 0.047 0.460 10.27 OK 9 0.031 0.460 6.67 OK 10 0.034 0.460 7.32 OK 11 0.040 0.230 17.23 OK 12 0.020 0.230 8.91 OK 13 0.015 0.230 6.66 OK 14 0.014 0.230 5.97 OK 15 0.019 0.230 8.25 OK 16 0.015 0.230 6.33 OK 17 0.024 0.230 10.60 OK 18 0.017 0.230 7.56 OK 19 0.008 0.230 3.51 OK 20 0.016 0.230 6.92 OK 21 0.013 0.230 5.72 OK 22 0.010 0.230 4.56 OK 23 0.007 0.230 3.24 OK 24 0.007 0.230 3.13 OK 25 0.014 0.230 6.04 OK 26 0.011 0.230 4.57 OK 27 0.008 0.230 3.51 OK 28 0.009 0.230 4.07 OK 29 0.005 0.230 2.12 OK 30 0.007 0.230 3.04 OK 31 0.008 0.230 3.64 OK 32 0.007 0.230 3.19 OK 33 0.005 0.230 2.23 OK 34 0.004 0.230 1.64 OK 35 0.006 0.230 2.43 OK 36 0.004 0.230 1.93 OK 37 0.006 0.230 2.79 OK 38 0.004 0.230 1.54 OK 39 0.004 0.230 1.95 OK 40 0.006 0.230 2.45 OK

Page 29: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 29 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

9. VOLTAGE FLUCTUATION AND FLICKER MEASUREMENT

9.1.Block Diagram of Test Setup

(EUT: Projection Alarm Clock)

9.2.Measuring Standard

EN 61000-3-3:2013

9.3.Measuring Results

Result: pass

PC

AC Power Source

AC Mains

Test analyzer Adapter EUT

Page 30: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 30 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Flicker Test Summary per EN/IEC61000-3-3 Ed. 3.0 (2013) (Run time)

EUT: Projection Alarm Clock M/N:HM433A Tested by: Frank Test category: All parameters (European limits) Test Margin: 100 Test date: 2019/6/14 Start time: 17:37:22 End time: 17:47:49 Test duration (min): 10 Data file name: F-000413.cts_data Comment: ON Report NO.:ATE20190803 Customer: Shenzhen YuanGuangHao Electronics Co., Ltd. Test Result: Pass Status: Test Completed Psti and limit line European Limits

0.25

0.50

0.75

1.00

Pst

17:4

7:4

3

Plt and limit line

0.00

0.25

0.50

0.75

1.00

Plt

0:0

0:0

0

Parameter values recorded during the test: Vrms at the end of test (Volt): 229.72 T-max (mS): 0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 7.00 Pass Highest Pst (10 min. period): 0.064 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.028 Test limit: 0.650 Pass

Page 31: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 31 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

10.ELECTROSTATIC DISCHARGE IMMUNITY TEST

10.1.Block Diagram of Test Setup

10.1.1.Block Diagram of the EUT

(EUT: Projection Alarm Clock)

10.1.2.ESD Test Setup

(EUT: Projection Alarm Clock)

10.2.Test Standard

EN 55014-2: 2015 (IEC61000-4-2: 2008 Severity Level: 3 / Air Discharge: ±8kV, Level: 2 / Contact Discharge: ±4kV) Testing shall also be satisfied at the lower levels.

10.3.Severity Levels and Performance Criterion

10.3.1.Severity level

Level Test Voltage Contact Discharge (kV)

Test Voltage Air Discharge (kV)

1. ±2 ±2

2. ±4 ±4

3. ±6 ±8

4. ±8 ±15

X Special Special

EUT

AC Mains AC Mains

ESD Tester

0.8 m

EUT Adapter

Page 32: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 32 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

10.3.2.Performance Criterion : B

10.4.Operating Condition of EUT

10.4.1.Setup the EUT as shown in Section 10.1.

10.4.2.Turn on the power of all equipments.

10.4.3.Let the EUT work in test mode and measure it.

10.5.Test Procedure

10.5.1.Air Discharge

This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 20 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed

10.5.2.Contact Discharge

All the procedure shall be same as Section 5.6.1 except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated.

10.5.3.Indirect discharge for horizontal coupling plane

At least 20 single discharges shall be applied to the horizontal coupling plane, at points on each side of the EUT. The discharge electrode positions vertically at a distance of 0.1m from the EUT and with the discharge electrode touching the coupling plane.

10.5.4.Indirect discharge for vertical coupling plane

At least 20 single discharges shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m * 0.5m, is placed parallel to and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated.

10.6.Test Results

PASS. Please refer to the following page.

Page 33: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 33 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Electrostatic Discharge Test Results Shenzhen Accurate Technology Co., Ltd.

Manufacturer: Shenzhen YuanGuangHao Electronics Co., Ltd.

Test Date : June 12, 2019

EUT: Projection Alarm Clock Temperature : 20ºC

Model No.: HM433A Humidity : 48%

Test Mode: ON Test Engineer : Frank

Air Discharge: ±2kV, ±4kV, ±8kV

Contact Discharge: ±2kV, ±4kV # For each point positive 10 times and negative 10 times discharge

Location Kind A-Air Discharge

C-Contact Discharge

Result

Non-conducted enclosure A PASS

Conducted enclosure C PASS

HCP C PASS

VCP of the front C PASS

VCP of the rear C PASS

VCP of the left C PASS

VCP of the right C PASS

Remark :

Test Equipment : ESD Simulator (TESEQ, NSG 437)

Discharge should be considered on Contact and Air and Horizontal Coupling Plane (HCP) and Vertical Coupling Plane (VCP).

Page 34: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 34 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

11.RF FIELD STRENGTH SUSCEPTIBILITY TEST

11.1.Block Diagram of Test

11.1.1.Block diagram of connection between the EUT and simulators

(EUT: Projection Alarm Clock)

11.1.2.Block diagram of R/S test setup

11.2.Test Standard

EN 55014-2: 2015 (IEC 61000-4-3: 2006 +A1:2007 +A2:2010, Severity Level: 2, 3V/m)

3 Meters

EUT

0.8 Meter

Anechoic Chamber

Power Amp Signal Generator

Measurement Room

EUT Adapter

Page 35: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 35 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

11.3.Severity Levels and Performance Criterion

11.3.1.Severity Level

Level Field Strength V/m

1. 1

2. 3

3. 10

X Special

11.3.2.Performance Criterion: A

11.4.Operating Condition of EUT

11.4.1.Setup the EUT as shown on Section 11.1.

11.4.2.Turn on the power of all equipments.

11.4.3.Let the EUT work in test mode and measure it.

11.5.Test Procedure

The EUT are placed on a table, which is 0.8 meter high above the ground. The EUT is set 3 meters away from the transmitting antenna, which is mounted on an antenna tower. Both horizontal and vertical polarizations of the antenna are set on test. Each of the four sides of the EUT must be faced this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD camera is used to monitor its screen. All the scanning conditions are as following: Condition of Test Remark ---------------------------------------------- --------------------------------------- 1. Fielded Strength 2. Radiated Signal 3. Scanning Frequency 4. Sweep time of radiated 5. Dwell Time

3V/m (Severity Level 2) Unmodulated 80-1000MHz 0.0015 Decade/s 1 Sec.

11.6.Test Results

PASS. Please refer to the following page.

Page 36: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 36 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

RF Field Strength Susceptibility Test Results Shenzhen Accurate Technology Co., Ltd.

Manufacturer:

Shenzhen YuanGuangHao Electronics Co., Ltd.

Test Date : June 11, 2019

EUT : Projection Alarm Clock Temperature : 25ºC

Model Number: HM433A Rating: DC 5V(Powered by charge port)

Field Strength : 3 V/m Humidity : 48%

Frequency Range: 80MHz to 1000 MHz Criterion : A

Test Mode : ON Test Location : Frank

Modulation: None Pulse

AM 1kHz 80%

Frequency Range 1:80-1000 MHz Frequency Range 2:

Steps # / % # / %

Horizontal Vertical Horizontal Vertical

Front PASS PASS

Right PASS PASS

Rear PASS PASS

Left PASS PASS

Test Equipment : 1. Signal Generator : SMB100A (Rohde & Schwarz) 2. Power Amplifier : MT310A (PRANA) 3. Bilog Antenna : VULB9163 (Schwarzbeck) Note:

Page 37: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 37 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

12.ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST

12.1.Block Diagram of Test Setup

12.1.1.Block Diagram of the EUT

(EUT: Projection Alarm Clock)

12.1.2.Block Diagram of the AC Mains

12.2.Test Standard

EN 55014-2: 2015 (IEC61000-4-4: 2012 Severity Level, Level 2: 1kV & 0.5kV)

12.3.Severity Levels and Performance Criterion

12.3.1.Severity level

Open Circuit Output Test Voltage ±10% Level On Power Supply Lines On I/O (Input/Output) Signal

data and control lines 1. 0.5 KV 0.25 KV 2. 1 KV 0.5 KV 3. 2 KV 1 KV 4. 4 KV 2 KV X Special Special

12.3.2.Performance Criterion : B

AC Mains EUT

AC Mains

EFT/B Tester

0.1 m

AC MainsAdapter EUT

Page 38: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 38 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

12.4.Operating Condition of EUT

12.4.1.Setup the EUT as shown in Section 12.1.

12.4.2.Turn on the power of all equipments.

12.4.3.Let the EUT work in test mode then measure it.

12.5.Test Procedure

The EUT is put on the table, which is 0.8 meter high above the ground. This reference ground plane shall project beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m.

12.5.1.For input and output AC power ports:

The EUT is connected to the power mains by using a coupling device, which couples the EFT interference signal to AC power lines. Both polarities of the test voltage should be applied during compliance test and the duration of the test is 2 mins.

12.5.2.For signal lines and control lines ports:

It’s unnecessary to test.

12.5.3.For DC output line ports:

It’s unnecessary to test.

12.6.Test Result

PASS. Please refer to the following page.

Page 39: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 39 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Electrical Fast Transient/Burst Test Results Shenzhen Accurate Technology Co., LTD.

Standard IEC 61000-4-4: 2012 Result : PASS / FAIL

Applicant : Shenzhen YuanGuangHao Electronics Co., Ltd. EUT : Projection Alarm Clock

M/N : HM433A

Input Voltage: DC 5V(Powered by charge port) Criterion : B Ambient Condition : 25 49% RH Operation Mode: ON

Line : AC Mains Line : Signal line DC output line

Coupling : Direct Coupling : Capacitive

Test Time : 120s

Line Test Voltage Result(+) Result(-)

L 1KV PASS PASS

N 1KV PASS PASS

PE

L、N 1KV PASS PASS

L、PE

N、PE

L、N、PE

Signal line

DC output line

Note :

Test Equipment Burst Tester Model : ULTRA COMPACT SIMULATOR: UCS 500 N5(EM TEST EM TEST) CAPACITIVE CLAMP: HFK (EM TEST)

Page 40: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 40 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

13.SURGE IMMUNITY TEST

13.1.Block Diagram of Test Setup

13.1.1.Block Diagram of the EUT

(EUT: Projection Alarm Clock)

13.1.2.Surge Test Setup

13.2.Test Standard

EN 55014-2: 2015 (IEC 61000-4-5:2014, Severity Level: Level 2, 1.0kV) Testing shall also be satisfied at the lower levels

13.3.Severity Levels and Performance Criterion

13.3.1.Severity level

Severity Level Open-Circuit Test Voltage KV

1 2 3 4 *

0.5 1.0 2.0 4.0

Special

11.3.2.Performance Criterion : B

0.1 m AC Mains

EUT

AC Mains

Surge Tester

AC MainsAdapter EUT

Page 41: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 41 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

13.4.Operating Condition of EUT

13.4.1.Setup the EUT as shown in Section 13.1.

13.4.2.Turn on the power of all equipments.

13.4.3.Let the EUT work in test mode then measure it.

13.5.Test Procedure

1) Set up the EUT and test generator as shown on Section 13.1.2. 2) For line to line coupling mode, provide a 1.0 KV 1.2/50us voltage surge (at

open-circuit condition) and 8/20us current surge to EUT selected points. 3) At least 5 positive and 5 negative (polarity) tests with a maximum 1/min

repetition rate are conducted during test. 4) Different phase angles are done individually. 5) Record the EUT operating situation during compliance test and decide the

EUT immunity criterion for above each test.

13.6.Test Result

PASS.

Please refer to the following page.

Page 42: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 42 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Surge Immunity Test Results Shenzhen Accurate Technology Co., LTD.

Applicant : Shenzhen YuanGuangHao Electronics Co., Ltd. Test Date : June 07, 2019

EUT : Projection Alarm Clock Temperature : 25

M/N : HM433A Humidity : 49%

Power Supply : DC 5V(Powered by charge port) Test Mode : ON

Test Engineer : Frank Criterion : B

Location Polarity Phase Angle Number of Pulse

Pulse Voltage (KV)

Result

L-N + 0o 5 0.5&1.0 PASS + 90o 5 0.5&1.0 PASS + 180o 5 0.5&1.0 PASS + 270o 5 0.5&1.0 PASS - 0o 5 0.5&1.0 PASS - 90o 5 0.5&1.0 PASS - 180o 5 0.5&1.0 PASS - 270o 5 0.5&1.0 PASS

L-PE + 0o 5 + 90o 5 + 180o 5 + 270o 5 - 0o 5 - 90o 5 - 180o 5

- 270o 5 N-PE + 0o 5

+ 90o 5 + 180o 5 + 270o 5 - 0o 5 - 90o 5 - 180o 5 - 270o 5

Remark:

Test Equipment : ULTRA COMPACT SIMULATOR: UCS 500 N5(EM TEST EM TEST)

Page 43: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 43 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

14.INJECTED CURRENTS SUSCEPTIBILITY TEST

14.1.Block Diagram of Test Setup

14.1.1.Block Diagram of the EUT

(EUT: Projection Alarm Clock)

14.1.2.Block Diagram of Test Setup

14.2.Test Standard

EN 55014-2: 2015 (IEC61000-4-6: 2013, Severity Level 2: 3V (rms), 0.15MHz - 80MHz)

14.3.Severity Levels and Performance Criterion

14.3.1.Severity level

14.3.2.Performance Criterion: A

Level Field Strength V(rms)

1. 1

2. 3

3. 10

X Special

Ground Reference Support

EUT CDN AC Mains

Signal Generator

Power Amplifier

0.1 m

AC MainsAdapter EUT

Page 44: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 44 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

14.4.Operating Condition of EUT

14.4.1.Setup the EUT as shown in Section 14.1.

14.4.2.Turn on the power of all equipments.

14.4.3.Let the EUT work in test mode then measure it.

14.5.Test Procedure

14.5.1.For AC Mains

1) Set up the EUT, CDN and test generators as shown on Section 14.1. 2) Let the EUT work in test mode and measure it. 3) The EUT are placed on an insulating support 0.1m high above a ground

reference plane. CDN (coupling and decoupling device) is placed on the ground plane about 0.3m from EUT. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible).

4) The disturbance signal described below is injected to EUT through CDN. 5) The EUT operates within its operational mode(s) under intended climatic

conditions after power on. 6) The frequency range is swept from 150kHz to 80MHz using 3V signal level,

and with the disturbance signal 80% amplitude modulated with a 1kHz sine wave.

7) The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding frequency value.

8) Recording the EUT operating situation during compliance testing and decide the EUT immunity criterion.

14.5.2.For signal lines and control lines ports:

It’s unnecessary to test.

14.5.3.For DC output line ports:

It’s unnecessary to test.

14.6.Test Results

PASS.

Please refer to the following page.

Page 45: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 45 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Injected Currents Susceptibility Test Results Shenzhen Accurate Technology Co., LTD.

Applicant: Shenzhen YuanGuangHao Electronics Co., Ltd. Test Date : June 08, 2019

EUT : Projection Alarm Clock Temperature : 24

M/N : HM433A Humidity : 47%

Power Supply : DC 5V(Powered by charge port) Test Engineer : Frank

Test Mode : ON

Frequency Range (MHz)

Injected Position Strength (Unmodulated)

Criterion Result

0.15 - 80 AC Mains 3V A PASS

Test Mode :

Frequency Range (MHz)

Injected Position Strength (Unmodulated)

Criterion Result

Remark : 1. Modulation Signal:1KHz 80% AM Measurement Equipment : Conducted Immunity Test System: CIT-10 (FRANKONIA) CDN : CDN-M2/3 (FRANKONIA) EM Injection Clamp: F-203I-23mm (FCC) Calibration Fixture: F-203I-23mm-CF (FCC)

Note:

Page 46: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 46 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

15.VOLTAGE DIPS AND INTERRUPTIONS TEST

15.1.Block Diagram of Test Setup

15.1.1.Block Diagram of the EUT

(EUT: Projection Alarm Clock)

15.1.2.Dips Test Setup

15.2.Test Standard

EN 55014-2: 2015 (IEC 61000-4-11:2004)

15.3.Severity Levels and Performance Criterion

15.3.1.Severity level

Test Level %UT

Voltage dip in %UT

Duration (in period)(50Hz)

Duration (in period)(60Hz)

0 100 0.5 1

0.5 1

40 60 10 12 70 30 25 30 80 20 250 300

15.3.2.Performance Criterion : C

0.1 m AC Mains

EUT

AC Mains

Dips Tester

AC MainsAdapter EUT

Page 47: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 47 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

15.4.Operating Condition of EUT

15.4.1.Setup the EUT as shown in Section 15.1.

15.4.2.Turn on the power of all equipments.

15.4.3.Let the EUT work in test mode then measure it.

15.5.Test Procedure

1) Set up the EUT and test generator as shown on Section 15.1.2. 2) The interruption is introduced at selected phase angles with specified

duration. 3) Record any degradation of performance.

15.6.Test Result

PASS.

Please refer to the following page.

Page 48: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 48 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Voltage Dips And Interruptions Test Results Shenzhen Accurate Technology Co., LTD.

Applicant : Shenzhen YuanGuangHao Electronics Co., Ltd. Test Date : June 09, 2019

EUT : Projection Alarm Clock Temperature : 25

M/N : HM433A Humidity : 49%

Power Supply : AC 230V/50Hz&AC 120V/50Hz Test Engineer : Frank

Test Mode: ON

Test Voltage: 230V/50Hz

Test Level

% UT

Voltage Dips & Short

Interruptions % UT

Duration (in periods) Criterion A B C D

Result P=Pass F=Fail

0 100 0.5P B PASS

40 60 10P/12Pa B PASS

70 30 25P/30Pa B PASS

Test Mode: ON

Test Voltage: 120V/50Hz

Test Level

% UT

Voltage Dips & Short

Interruptions % UT

Duration (in periods) Criterion A B C D

Result P=Pass F=Fail

0 100 0.5P B PASS

40 60 10P/12Pa C PASS

70 30 25P/30Pa C PASS

a “10P/12P” means “10 cycles for 50Hz test ” and “12 cycles for 60 Hz test”

Remark: UT is the rated voltage for the equipment.

Test Equipment : ULTRA COMPACT SIMULATOR: UCS 500 N5(EM TEST EM TEST)

Page 49: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 49 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

16. TEST PHOTOGRAPHS

16.1.Photo of Conducted Emission Measurement

16.2.Photo of Disturbance Power Test

Page 50: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 50 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

16.3.Photograph of set-up for Radiated susceptibility

16.4.Photo of Electrostatic Discharge Immunity Measurement

Page 51: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 51 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

16.5.Photo of Electrical Fast Transient /Burst Test

16.6.Photo of Surge and Voltage Dips and Interruption Immunity Test

Page 52: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 52 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

16.7.Photo of Injected Current Susceptibility Test

16.8.Photo of flicker Test

Page 53: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 53 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

17.PHOTOGRAPHS OF THE EUT

Page 54: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 54 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Page 55: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 55 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Page 56: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 56 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Page 57: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 57 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Page 58: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 58 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com

Page 59: EMC TEST REPORT for Shenzhen Qianhai Patuoxun ......Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http:// Test Report Declaration Applicant : Shenzhen Qianhai

Report No.: ATE20190903

Page 59 of 59

Shenzhen Accurate Technology Co., Ltd.

Address: 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China

Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: [email protected] Http://www.atc-lab.com